Loading...
HomeMy WebLinkAbout156 BERRY PATCH BUILDING 8 Electric# fq E3APPLICATION FOR BUILDING PERMIT Plumbing# `1 156 Berry Patch (Building 8) Date: n n T 9 a gnnn4 I-IVAC # /Q-(e v Sprinkler# /`{�D FINAL APPROVALS Estimated Cost Ztl d,000.00 Building COMPLETE RED BOXED AREAS Permit Fee $ D Engineering Occupancy Fee $ j a g TYPE OR PRINT ONLY En Ins Fee $ Appr.ffid or 6. ► SIGN ON REVERSE SIDE g� p� 3�p C Total Fee $ TO THE BUILDING D ARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant The Metro Construction core_ Location of Work 156 Berry Patch Lot No. 213 Applicant's Address 6 Executive Drive, Suite 100 Tel.# 860-674-5640 Town Farmi n nn, CT Zip 06032 Lic.#gyp g00434 Owners patch TT SGtx-i a c L. P Architect Associated Architects Owner's Address 6 Executive Drive, Suite 100 Architect's Address 16 Spring Lane Farmington, CT Zip 06032 Farmington, Cr Zip06032 Sq. Ft. New Area: 1 st FI. A96 2nd FI. --- 3rd FI. --- Total New Area 896 Purpose of this permit New Construction - multiple single family affordable dwelling City WaterN Well❑ Septic System❑ Sewer] Ins: HO SP Cert. Area Basement Garage Approved by Date Use Group Construction Type /`{� R4rAs*d 6102 V T j ✓1./'-., I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of 04 South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be bcated the proper distance from all street lines,side yard lines,and required distances from all other zones and is kxated in which this building and its use is allowed. THE METRO CONSTRUCTION COk Signed tar"Zr ?res�� I hereby apply for a Certificate of Occ f the work described in this apple oni -f Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-31230-B 22,000 BO1 FOOTING 07/07/05 CJD A P02 UNDERGROUND 09/13/05 CJD A BO1 FOOTING 06/29/05 PJP A FROST WALL W/COMPACTION P02 UNDERGROUND 07/11/05 PJP A WEST WING E03 ROUGH 02/10/06 PJP A W/DAN&JIM PO4 GAS TEST 02/17/06 PJP A P03 ROUGH 02/17/06 PJP A P03 ROUGH 02/28/06 PJP A COPPER PRESSURE TEST B03 FRAMING (ROUGH) 02/28/06 PJP A B04 INSULATION 03/01/06 PJP A B04 INSULATION 03/08/06 PJP A CEILINGS **-1480-S 2,000 **-12604-H 6,000 **-11789-P 5,000 **-19353-E 2,700 BUILDING INSPECTION DEPARTMENT TOWN of SOUTH"Wf'X_SOR,_CONNECTICUT a .. e # z . C E R T I _. I C T EQ „ (_',» tl'°C ' t PNA N C Y ZONE: -July 5 2006 This is to certifytha�`,, S6"BE I2Y B1TCtautider°permiC� No 31230 conforms suba +ar�tla� ly�to tk�ei reguiremetit�'•G the Qonnecticut Basic Building coPe e6)ad'.t.he"zgziing:Vx i 1ae i 8f f pwn pf South Windsor and' ISA. hki6tjy 'roved>46j7 occupang s''as;' ; cated pf� y . „i� y .• below Approved for Occdpnii6y9` 'MI3I:'LI-STNGtE�"1?AN},�TY::`:DWELLxt3G"-';r� ^e($uxI,I�z�1G '"S,ry,,;.,x.,;Yrr�v • '" r q+" .s>f "40�;.»'r;'!t:�>°" :�^• .-x.y�.",�.s.:i'Via. ^r�`..<!f :'+sn� 2, Use Group R3 Constr. Type 5B Official Notice If this certif.�ical,: ',, s Tbst �r�d@ o md,4 a'duplicate should be obtained immedi te1�;T€po thgkiding 'Department Any change or extension of "eh-e--tad' °"h rein approved requires a new certificate of occupancy. DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE p n ► Bldg.Permit 644-2511 ext. 230 # 3 l a30 Date Buil mg I pector Application must be printed or typed FEE SCHEDULE Location of Job: 156 arty Patch 2 B $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc, APPLICANT ADDRESS 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# . (860) 623-1991 O W N S f q OWNER _Berry Patch II Associates Limited Partnership r >` OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr. 06032 OWNER PHONE (860) 674-5641 ESTIMATED COST$6 ,0 0 0 . 0 0 "f. IS THIS A CONTRACT COST? %Yes _No Q 4� FEE ENCLOSED$ 9 0 . 0 0 TYPE OF JOB: Sp R•C X New Installation —Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: ®HEATING $kRESIDENTIAL 50 A/C ❑COMMERCIAL ® VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC MWARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE °F DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) _ Magic Pak M/N 51HWE743A 2, Armstrong — GROSS BEATING CAPACITY(LNPUT—BTUIT)51 ,0 0 0 NET RATING(OUTPUT—BTUH) 40,000 TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY ® GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF P e r TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) P 1 a n s DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) & Specs TONNAGE 2 COOLING CAPACITY(BTUH) 24,000 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 303755 S-1 CT CONTRACTORS LICENSE NO. TYP STATE SIGNATURE OF APPLICANT DATE `> r � ^US DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT /`Y�O APPROVED 1540 SULLIVAN AVENUE ul.--2 0 ' Out ing nspe r644-2511 ext. 230Bldg.Permit# Date ( -Z 3 U Application must be printed or typed FEE SCHEDULE Location of Job: 156 Berry Patch . 2 B $0-$1,000=$15.00 Street No. Street Over$1,000= Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation — -- Apt.No, APPLICANT Thomas L. Jacquel c/o Allstate Fire Sprinkler, Inc. APPLICANT ADDRESS, P.O. Box 2350 Hartford, Cr 06146 APPLICANT PHONE# (860) 246-7711 OW N SF OWNER Berry Patch II Associates Limited -Partnership OWNER ADDRESS 6 Executive Drive Suite 100 co� r Farmington, Cr' 06032 OWNER PHONE (860) ,674-5641 ` ESTIMATED COST $2 000.00 `S+ IS THIS A CONTRACT COST? X Yes No s, % CJ FEE ENCLOSED$ 3 0.0 0 d TYPE OF JOB:SOR,COS X _New Installation Alteration/Addition/Repair R—i-4 A/Al//Nnn1 APPLICATION FOR SPRI\rKI.ER PERMIT (Continued from reverse side) TYPE OF BUILDING TYPE OF CONSTRUCTION 5B USE GROUP NO. OF STORIES M RESIDENTIAL ElRESI'iv IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PFRIWF APPLICATION? ❑YES ❑ NO ❑MERCANTILE ❑ EDUCATIONAL CURRENT USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ❑ STORAGE ❑ GARAGE ENGINEER'S NAME David K• Thoffpson PHONE(860) 246-7711 ❑MIXED USE (Other please specify) ADDRESS P.O. Box 2350 CITY Hartford STATE CT ZIP 06146 KIND OF INSTALLATION SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI) ARE SPRINKLER HEADS ALTERED? ® YES ❑NO IF YES,CHECK ALL THAT APPLY: ®ADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) CH PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES W NO IF YES,CHECK ALL THAT APPLY: ❑FIRE ❑BOOSTER ❑OTHER ARE STANDPIPES PROVIDED? ❑YES ®NO IS A SPRINKLER SYSTEM PROVIDED? W YES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP N/A PSI DESCRIPTION OF WORK New fire sprinkler system in two bedroom unit THE U-DERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK F10590 Fire Sprinkler CT CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT#�5 TOWN OF SOUTH WINDSOR Application is hereby: J 3 BUILDING DEPARTMENT / (APPROVER 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg. Permit# 232004 � 1 a3 0 Date uilding Inspecto Application must be printed or typed FEE SCHEDULE Location of Job: 156 Berry Patch 2B $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereon Tenant Designation Apt.No. APPLICANT J—Electric APPLICANT ADDRESS 8 Sanrico Drive Manchester, Cr 06040 APPLICANT PHONE# (860) 645-9891 O W N SF OWNER Berry Patch II Associates Limited Partnership OWNER ADDRESS 6 Exec-utive Drive, Suite 100 F Cr 06032 OWNER PHONE (860) 674-5641 C ESTIMATED COST$ 2,700.00 IS THIS A CONTRACT COST? X Yes No y 1001, a4� FEE ENCLOSED$ 45.00 � �� TYPE OF JOB: SpR.CO R New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION? 0 YES ❑NO O BUSINESS CURRENT USE AND OCCUPANCY 0 ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY Residence ❑ EDUCATIONAL ❑ INSTITUTIONAL F3�Ca]I, ❑FACTORY ENGINEERS NAME i xi rnPHONE (860) 257-3968 0 STORAGE 203 Briar`aood Court ❑ GARAGE ADDRESS ❑MIXED USE CITY sky Hill STATE Cr ZIP 06067 (Other please specify) TYPE OF INSTALLATION/WIRING METHOD NMC SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS #2 Al NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8 NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23 NUMBER OF LIGHT FIXTURES 9 NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS 1 SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Interior wiring of apartment to include outlets, switches and their Dover plates. Wiring of appliances and HVAC unit. Install light fixtures. Install 100 amp breaker panel. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 123580 Fr 1 Cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR I "7 9 c) BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# DEC[' 3ra3o_ at uilding nspe r Application must be printed or typed FEE SCHEDULE Location of Job: FTenant Berry Patch 2B $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# (860) 623-1991 O W N St OWNER Berry Patch II Associates Limited Partnership q< OWNER ADDRESS 6 RKwutive Drive, Suite 100 Farmington, Cr 06032 O F, OWNER PHONE (860) 674-5641 C ESTIMATED COST$ 5,000.00 IS THIS A CONTRACT COST? X Yes —No t - '�s✓ FEE ENCLOSED$ 75.00 TYPE OF JOB: DSO R•C o X New Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERTWF APPLICATION? ❑YES ❑ NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑ GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4" NO.OF TOILETS 1 STYLE Elongated NO.URINALS N/A SSE N/A NO. OF BATHTUBS NO. OF SHOWERS 1 NO.OF LAVATORIES 1 NO. OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3 AREA OF ROOF Back NO.OF CATCH BASINS N/A NO. OF FLOOR DRAINS 1 Kitchen NO. OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES 91 NO SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4 Weil Mclain WATER HEATER: TYPE Indirect MANUFACTURER P/US 120 DESCRIPTION OF WORK COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P-1 00204480 P-1 Cl! CONTRACTORS LICENSE NO. TYPE STATE / SIGNATURE OF APPLICANT Q DATE