HomeMy WebLinkAbout156 BERRY PATCH BUILDING 8 Electric# fq E3APPLICATION FOR BUILDING PERMIT
Plumbing# `1 156 Berry Patch (Building 8) Date: n n T 9 a gnnn4
I-IVAC # /Q-(e v
Sprinkler# /`{�D
FINAL APPROVALS Estimated Cost Ztl d,000.00
Building COMPLETE RED BOXED AREAS Permit Fee $ D
Engineering Occupancy Fee $ j a
g TYPE OR PRINT ONLY En Ins Fee $
Appr.ffid or 6.
► SIGN ON REVERSE SIDE g� p� 3�p
C Total Fee $
TO THE BUILDING D ARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant The Metro Construction core_ Location of Work 156 Berry Patch Lot No. 213
Applicant's Address 6 Executive Drive, Suite 100 Tel.# 860-674-5640
Town Farmi n nn, CT Zip 06032 Lic.#gyp g00434
Owners patch TT SGtx-i a c L. P Architect Associated Architects
Owner's Address 6 Executive Drive, Suite 100 Architect's Address 16 Spring Lane
Farmington, CT Zip 06032 Farmington, Cr Zip06032
Sq. Ft. New Area: 1 st FI. A96 2nd FI. --- 3rd FI. --- Total New Area 896
Purpose of this permit New Construction - multiple single family affordable dwelling
City WaterN Well❑ Septic System❑ Sewer]
Ins: HO SP Cert. Area Basement Garage
Approved by Date Use Group Construction Type
/`{� R4rAs*d 6102
V T j
✓1./'-.,
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of 04
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be bcated the proper distance from all street lines,side yard lines,and required
distances from all other zones and is kxated in which this building and its use is allowed.
THE METRO CONSTRUCTION COk
Signed tar"Zr
?res��
I hereby apply for a Certificate of Occ f the work described in this apple oni -f
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-31230-B 22,000
BO1 FOOTING 07/07/05 CJD A
P02 UNDERGROUND 09/13/05 CJD A
BO1 FOOTING 06/29/05 PJP A FROST WALL W/COMPACTION
P02 UNDERGROUND 07/11/05 PJP A WEST WING
E03 ROUGH 02/10/06 PJP A W/DAN&JIM
PO4 GAS TEST 02/17/06 PJP A
P03 ROUGH 02/17/06 PJP A
P03 ROUGH 02/28/06 PJP A COPPER PRESSURE TEST
B03 FRAMING (ROUGH) 02/28/06 PJP A
B04 INSULATION 03/01/06 PJP A
B04 INSULATION 03/08/06 PJP A CEILINGS
**-1480-S 2,000
**-12604-H 6,000
**-11789-P 5,000
**-19353-E 2,700
BUILDING INSPECTION DEPARTMENT
TOWN of SOUTH"Wf'X_SOR,_CONNECTICUT
a ..
e # z .
C E R T I _. I C T EQ „ (_',» tl'°C ' t PNA N C Y
ZONE:
-July 5 2006
This is to certifytha�`,, S6"BE I2Y B1TCtautider°permiC�
No 31230 conforms suba +ar�tla� ly�to tk�ei reguiremetit�'•G the Qonnecticut
Basic Building coPe e6)ad'.t.he"zgziing:Vx i 1ae i 8f f pwn pf
South Windsor and' ISA. hki6tjy 'roved>46j7 occupang s''as;' ; cated
pf� y . „i� y .• below
Approved for Occdpnii6y9` 'MI3I:'LI-STNGtE�"1?AN},�TY::`:DWELLxt3G"-';r�
^e($uxI,I�z�1G '"S,ry,,;.,x.,;Yrr�v
• '"
r q+" .s>f "40�;.»'r;'!t:�>°" :�^• .-x.y�.",�.s.:i'Via. ^r�`..<!f :'+sn� 2,
Use Group R3
Constr. Type 5B
Official
Notice If this certif.�ical,: ',, s Tbst �r�d@ o md,4 a'duplicate should
be obtained immedi te1�;T€po thgkiding 'Department
Any change or extension of "eh-e--tad' °"h rein approved requires
a new certificate of occupancy.
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
Application is hereby:
TOWN OF SOUTH WINDSOR PERMIT#
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE
p n ► Bldg.Permit 644-2511 ext. 230 #
3 l a30
Date Buil mg I pector
Application must be printed or typed
FEE SCHEDULE Location of Job:
156 arty Patch 2 B
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT Fahrenheit Mechanical Services Inc,
APPLICANT ADDRESS 56 Depot Street
Broad Brook, Cr 06016
APPLICANT PHONE# . (860) 623-1991
O W N S f q OWNER _Berry Patch II Associates Limited Partnership
r >`
OWNER ADDRESS 6 Executive Drive, Suite 100
Farmington, Cr. 06032
OWNER PHONE (860) 674-5641
ESTIMATED COST$6 ,0 0 0 . 0 0
"f. IS THIS A CONTRACT COST? %Yes _No
Q 4� FEE ENCLOSED$ 9 0 . 0 0
TYPE OF JOB:
Sp R•C X New Installation
—Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF SYSTEM: TYPE OF BUILDING:
®HEATING $kRESIDENTIAL
50 A/C ❑COMMERCIAL
® VENTILATION ❑INDUSTRIAL
HEATING
❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC MWARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE °F DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
_ Magic Pak M/N 51HWE743A 2, Armstrong —
GROSS BEATING CAPACITY(LNPUT—BTUIT)51 ,0 0 0 NET RATING(OUTPUT—BTUH) 40,000
TYPE OF FUEL
❑OIL—GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY
® GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF P e r
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) P 1 a n s
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) &
Specs
TONNAGE 2 COOLING CAPACITY(BTUH) 24,000
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
303755 S-1 CT
CONTRACTORS LICENSE NO. TYP STATE
SIGNATURE OF APPLICANT DATE `> r � ^US
DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT
Application is hereby: TOWN OF SOUTH WINDSOR PERMIT#
BUILDING DEPARTMENT /`Y�O
APPROVED 1540 SULLIVAN AVENUE
ul.--2 0 '
Out ing nspe r644-2511 ext. 230Bldg.Permit#
Date ( -Z 3 U
Application must be printed or typed
FEE SCHEDULE Location of Job:
156 Berry Patch . 2 B
$0-$1,000=$15.00 Street No. Street
Over$1,000= Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation — --
Apt.No,
APPLICANT Thomas L. Jacquel c/o Allstate Fire Sprinkler, Inc.
APPLICANT ADDRESS, P.O. Box 2350
Hartford, Cr 06146
APPLICANT PHONE# (860) 246-7711
OW N SF OWNER Berry Patch II Associates Limited -Partnership
OWNER ADDRESS 6 Executive Drive Suite 100
co� r Farmington, Cr' 06032
OWNER PHONE (860) ,674-5641
` ESTIMATED COST
$2 000.00
`S+ IS THIS A CONTRACT COST? X Yes No
s, % CJ FEE ENCLOSED$ 3 0.0 0
d TYPE OF JOB:SOR,COS X
_New Installation
Alteration/Addition/Repair
R—i-4 A/Al//Nnn1
APPLICATION FOR SPRI\rKI.ER PERMIT (Continued from reverse side)
TYPE OF BUILDING TYPE OF CONSTRUCTION 5B USE GROUP NO. OF STORIES
M RESIDENTIAL
ElRESI'iv IS THIS APPLICATION ASSOCIATED WITH A
❑ASSEMBLY BUILDING PFRIWF APPLICATION? ❑YES ❑ NO
❑MERCANTILE
❑ EDUCATIONAL CURRENT USE AND OCCUPANCY
❑INSTITUTIONAL
❑FACTORY FUTURE USE AND OCCUPANCY
❑ STORAGE
❑ GARAGE ENGINEER'S NAME David K• Thoffpson PHONE(860) 246-7711
❑MIXED USE
(Other please specify) ADDRESS P.O. Box 2350
CITY Hartford STATE CT ZIP 06146
KIND OF INSTALLATION
SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI)
ARE SPRINKLER HEADS ALTERED? ® YES ❑NO
IF YES,CHECK ALL THAT APPLY: ®ADDED ❑DELETED ❑ALTERED
IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE)
CH PROFESSIONAL ENGINEER ❑INSURANCE COMPANY
WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI)
ARE PUMPS REQUIRED? ❑YES W NO IF YES,CHECK ALL THAT APPLY:
❑FIRE ❑BOOSTER ❑OTHER
ARE STANDPIPES PROVIDED? ❑YES ®NO IS A SPRINKLER SYSTEM PROVIDED? W YES ❑NO
SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM
TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP N/A PSI
DESCRIPTION OF WORK
New fire sprinkler system in two bedroom unit
THE U-DERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK
F10590 Fire Sprinkler CT
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
PERMIT#�5
TOWN OF SOUTH WINDSOR
Application is hereby: J 3
BUILDING DEPARTMENT /
(APPROVER 1540 SULLIVAN AVENUE
644-2511 ext. 230 Bldg. Permit#
232004 � 1 a3 0
Date uilding Inspecto
Application must be printed or typed
FEE SCHEDULE Location of Job:
156 Berry Patch 2B
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereon Tenant Designation Apt.No.
APPLICANT J—Electric
APPLICANT ADDRESS 8 Sanrico Drive
Manchester, Cr 06040
APPLICANT PHONE# (860) 645-9891
O W N SF OWNER Berry Patch II Associates Limited Partnership
OWNER ADDRESS 6 Exec-utive Drive, Suite 100
F Cr 06032
OWNER PHONE (860) 674-5641
C ESTIMATED COST$ 2,700.00
IS THIS A CONTRACT COST? X Yes No
y 1001,
a4� FEE ENCLOSED$ 45.00
� �� TYPE OF JOB:
SpR.CO
R New Installation
Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
RESIDENTIAL BUILDING PERMIT APPLICATION? 0 YES ❑NO
O BUSINESS CURRENT USE AND OCCUPANCY
0 ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY Residence
❑ EDUCATIONAL
❑ INSTITUTIONAL F3�Ca]I,
❑FACTORY ENGINEERS NAME i xi rnPHONE (860) 257-3968
0 STORAGE 203 Briar`aood Court
❑ GARAGE ADDRESS
❑MIXED USE
CITY sky Hill STATE Cr ZIP 06067
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD NMC
SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS #2 Al
NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS
NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES ❑NO
NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8
NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23
NUMBER OF LIGHT FIXTURES 9 NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS 1
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
Interior wiring of apartment to include outlets, switches and their Dover
plates. Wiring of appliances and HVAC unit. Install light fixtures.
Install 100 amp breaker panel.
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
123580 Fr 1 Cr
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR I "7 9 c)
BUILDING DEPARTMENT
APPROVE 1540 SULLIVAN AVENUE
644-2511 ext. 230 Bldg.Permit#
DEC[' 3ra3o_
at uilding nspe r
Application must be printed or typed
FEE SCHEDULE Location of Job:
FTenant
Berry Patch 2B
$0-$1,000=$15.00 Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof gnation Apt.No.
APPLICANT Fahrenheit Mechanical Services Inc.
APPLICANT ADDRESS 56 Depot Street
Broad Brook, Cr 06016
APPLICANT PHONE# (860) 623-1991
O W N St OWNER Berry Patch II Associates Limited Partnership
q< OWNER ADDRESS 6 RKwutive Drive, Suite 100
Farmington, Cr 06032
O
F, OWNER PHONE (860) 674-5641
C ESTIMATED COST$ 5,000.00
IS THIS A CONTRACT COST? X Yes —No
t - '�s✓ FEE ENCLOSED$ 75.00
TYPE OF JOB:
DSO R•C o X New Installation
_Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERTWF APPLICATION? ❑YES ❑ NO
❑RESIDENTIAL
❑BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY
❑EDUCATIONAL
❑ INSTITUTIONAL
❑FACTORY ENGINEER'S NAME PHONE
❑ STORAGE
❑ GARAGE ADDRESS
❑MIXED USE
CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4"
NO.OF TOILETS 1 STYLE Elongated NO.URINALS N/A SSE N/A
NO. OF BATHTUBS NO. OF SHOWERS 1 NO.OF LAVATORIES 1
NO. OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3
AREA OF ROOF Back NO.OF CATCH BASINS N/A NO. OF FLOOR DRAINS 1
Kitchen
NO. OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES 91 NO
SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR
SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer
SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4
Weil Mclain
WATER HEATER: TYPE Indirect MANUFACTURER P/US 120
DESCRIPTION OF WORK
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
P-1 00204480 P-1 Cl!
CONTRACTORS LICENSE NO. TYPE STATE
/
SIGNATURE OF APPLICANT Q DATE