Loading...
HomeMy WebLinkAbout151 JACQUES LN Revised 4/01//2002 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is here G dco BUILDING DEPARTMENT LA6RO CLe-� 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Bu ing Inspector Application must be printed or typed FEE SCHEDULE FtTenant Location of Job: $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 _ or any fraction thereof gnation Apt.No. APPLICANT \-I l f j C-4= - O /L l S APPLICANT ADDRESS IS 1A 9 S L A Lv/n 77 ,a2- C' r o(,07q APPLICANT PHONE# 5Z — SOW N s Fp OWNER /N C c/v t g' Cz- Z g /36 /Zf cam►S OWNER ADDRESS 161 T C( DES L�ivc: OWNER PHONE C ESTIMATED COST$ -2/O 0,D IS THIS A CONTRACT COST? _Yes _No Q �G FEE ENCLOSED$ 15, Db TYPE OF JOB: SOR-C0 New Installation Alteration/Addition/Repair APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING �W RESIDENTIAL A/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR )4 UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Vrkrr FeEE � AS Lo& 146A i E� - LOCATio1 : Mi�� �oo�+a 1/ArVa4p ESA KE?lby A4DD6�- V0A 4/Jk3 Fl-AML MAu S&r,4;efj7Z�'s#&roFi(-- GROSS HEATING CAPACITY(INPUT—BTUH) a SUD 0" fiET RATING(OUTPUT—BTUH)a�b "3 9 0 c' TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑ INSIDE❑ OUTSIDE CAPACITY I�;GAS—INPUT i ty-14 LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PEUOR SCE OF SUCH WORK. /Y iG,m3 ff�� - G.� 7- �►�n P f�c a#� CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT ./t rv� �'/!J^--�t� DATE �/i Ll 0 Im to pq E. RTyppa k A samiauff CIVU tngittem Gis stw bury, Connecticut SFHC.E 1:J � g� 2Z� v % Y ro \ All ivVr1cla io m 1 1`� 1� o \ « C L �+'• p t11'L A ti z', zo \ a, U 1b 1E I (j ` \ I 11 � <--CSCTtgt� Tn ' �iXM.1C:�Tto+-� `L.oiClaT1EC .p` S:�r1+.1 -Z�$4 i�O I Not.Z.;�q,T �►v.,4,• c.IC.. 50�1rwzE�-rwr�cT. '.-1a,�c-t�cxP. L4� Z04.44 - VIAL G�1.(�►1 C0.4". env envr: t Cw.cA,r. ' z�E.':.a'•�n_a.Y_� <�owve-.af 4 JFVMi Lot Linw from sap an file In Town Clerk'# Office entitled, *Plot Plan Section 4✓ neaaant Valley Rarea South Wiadsw, Conn." Scale 1•- L0l Dab - 8 r A-20 'tONF- YAp No. 220-7&-1 U Rev. by Rei no E. hyyppa & Associates Glastonbury. CT. PP PAS2 L 0 FO Q I tweby rertify th,t this mao and survey were prepMed in PLEASANT VA L L.Ek-Y W V M ES a000rdance with the standards of a Class A•2 survey as defined 6 the exlstft Code of Pra-ti;.e fo► Standards of Accuracy of SOUTH V41NDSOR, Owwp and Maps, adopted by the Coruectkut Amwe ation sf L►aa/ ie�►wy�oes. ire. SGA\-E 4.,.4.0. poly _4 South Windsor BUILDING DEPARTMENT M THE IUILDIK DDT. TOWN Or SOUTh WUiDSOR This certified that this Plan and sprClfications are true ooples of the proposed building or alterations to be erected at r d 4CV' Street together with amendments stated In appllcetion ems filed with plan and 1 agree to comply with all zonln F,. Building and state laws and such orders as shall b,. Issued he Building Department during pendency of this PP11 atIon and final Iswanee of bui+ Permit, ilIned this Pla � rpprwM Me �swthfon that iWde►s anti egla tIjg •MAt she" be @0nditinnaty ApprrfeM 16we iNeA with .Building inspadrpr Me. / �1 vV/1 93i e/rr^J CERTIFICATION OF ZONING COMPLIA iCE g;s useis) and!or structul-!s1 Proposed building), ,Yl r^� `:y .n as shovin on this play apP�" ' I.1 �l ?r conform •i ance with cu�r„ . �' L=;, regulations. Va'-�ances a d sp_t:iI ex�:'ans may apPly. 1 Date — Zonis; Eclforc:r�cenfi Of';tcer 1• R77Ppa A Apoaiaf Chit tnprs , G!r•stvnDtry, ComecmW SrH_E II 7 v, \I rO Tj t L + L►� �+ l i41 IIL izo U E �j T.o4_I LO�A�EZ �� 5: 1�1 �Z�$4 . Noi«�a�J�t S►VI.J(p! G•G %m "ierA—L�'S�JE-. t1C "v.��i �JIDI..L'�10►•��. + ��.Iu. O!..[-.": l �N+ClSj T•TuE. U:.��.i�Vt �-J�MVIC.d'j �, i Lot Baca from slap an file in v,►,,w,� t i EuL.w_, c. tti,R t•, "am Clerk's Office entitled, INFlot plan Action E neaaant ♦alley wamw i ,Oath Nindew, Conn." a1e In- IA/ DeL No, 220-78-!U awl -- by Re 1 no E. yyppa A Associates Glastonbury. CT, PQF-PARED FOR i Aweby certify thIt this "r° and survey ware Propered hi PLE L�S�►NT VALLEY I-�01v1�5 with the standards of a Clam A•2 survey as deftneC ft exbting Code of Pro-tire for Standard: of Accuracy of 50UTN W1NDSORI CONN ��WO h4eaps edoptad by fM GorinecfiuR Aaao+cistlo , of ML c C.-it �. 10 (';'.I'N 1& Of This Caro t rV, topics of .r r .Y • , t tj be sneted at tetnther t t and thed Itt pi n and ;:I t ling, BYiM• d St V 1 v s . d ;t be ben:d the o tldrvg u p It '"nCY of t•1, ..pj.C.tj.n and irncl Is• I ;,ding permit. Slgned __ Titlt t•n P% a'r v d subject t t that Ord..► •o; nC.e r &A rn: I be so Cet;o.tt.. u r ved tna: t •nth Budu ng ;.t,v cWr --- _100 Otte l !. ATyppa is A"odeftir Civil Englrgem Wastvnbury# Connecticut OPEN � J - }Q i b •des? la! I C(,4) n \ 3 Q Z Q L \ 16 lf� � W 2 \ J too LL m -.�o►r.1G�r+tto►-1 LoUL�EC A`_ S►-l�v1�! -Z�$4 � �b�.�y�.,,t �+v�.,�� c.G. yo�..-rs��:�crr,+cc-�'. ►��,�sw..v. Na Zo►. w- \ IDLo-to►.11 Cw.u":W� T.CuE `u`,�r.bY_F GoHtro+a( JFMI Lot liiea from nap an file in vl,,c�►,� a Euz..ec�y c. MnR� a ?barn Clerk's Office entitled, "Plot Plan Seotion E Yleaeaat Valley Ramon South Windeoe, Coon." Scale 1•- b0' Date -.:8 1 A,-ILO ZONE Imp No. 220-76-I U Paw, — by Re t no E. llyyppa & Associates Glastonbury, CT. Pf2r-PARE.O FOR I hweby ctrti}y that this moo mid sunray were prepared Ito PLEASANT VALLEY WOMES scordame with the standards of a Class A•2 survey as defined M Ma existing Code of Pro-tice for Standards of Accuracy of 54UTW WINDSOR, CONN Muretra and Maps, adopted by the Corumc6wt Aaaocimho of LOW i�aw )w% ML SU►�E I � eeP%.8 8 4 fccv. �-e-eo �� 4vos.o 43-Zq-ib4 rdle tl„'• 'rut TO J-g a 'his"rtt 1 U„t tr,i; pl,n rnd aP'- COpi s' of t,e pro V,sad budding or arectnd at toe(ther �' t t I C11"ply with filed with nl n ,�nJ 1 F ,rd rs as •n II Budar�g end st tr I,ws a_d s"�h pendent; the Buddmg Dep.rtm-nt daring pb,lldln lasu.A by IlcaLon and final issuanca of a of this apV permit. Signed subject to the condition This p th lan is ape r Ved building shot% n orders and ordlancen rc.gule[mg compiled with. 7hess filed wit Condlttonady Approved C Building Inspector 110. ostio 10 r Raino E. Hyn9a k A ssoaiates Clvil Engineers Glastonbury, Connecticut I 3 a k� \ r N r) ,O of fib to ' f Q s fb� LL (9ilea Z @ PoantvAstoN 4 j<O No ZOI+iW. \Jj0L rI0"-, .MOTE: Lot limes from sap on file in Town Clerk's Office entitled, "Plot Plan Section P'leaeant Valley Homes South Windsor, Conn." Scale 1"- 40' Data - - A-20 7-0we Map No, 220-78-- 1 L) Rear. by Reino E . Nyyppa b Associates Glastonbury, CT, PREPARED FOR I hereby re-tity thit this mao anti survey were prepared iii pLEASQNT VALLEY G--IOVIES accordance with the standards of a Class A 2 survey as defined In the existing Code of Pra-tice for Standards of Accuracy of SO UTN W 1 NQSO R, O�j N. lurver and Maps, adopted by the Comm0cut Association of �ATfl Land Surveyors Inc- . • • SCANNED s six,-y AP_ PR0VED TO`NN O? S^I 'T: ` II',"^SOR ENG�N=PFZINGp DEPA.TP.iC,IT DATE: '}yy�����Z -1 Raim E. Hyyppe k A saociatbir Civil Erglneers Glastonbury, Connecticut ot>F-N 0 � a , � O = L a � A 4 LP 1 00� C7. CY qq S ,(o° \ tz I CP ire .NOTE: Lot lime from asp on f lie in Town Cleric's Office entitled, "Plot Plan Section Pleasant Valley Hoses South Windsor, Conn." Scale 1"- b0l Date 3-2 6 La-20 mpN E Map No. 220-115-r u Rom. — by Re i no E. Hyyppa b Associates Glastonbury. CT. p121!PLaR E C) FOR!� I hbreby rertity thit this mac and survey were prepared iri pLE QSA NT VALLEY �- O V ES accordance with the standards of a Class A 2 survey as defines! In the existing Code of Pre-ti:.e for Standards of Accuracy of SO UT44 W I NDSOQ, C 0w N Owwys and Maps. adopted by no Connecticut Arocistion of Lww Surveyom tnt. SCALE D°`Te -8-9 Reioo E. Hyyppa k Associstes Civil Engineers Gfastorlbury, Connecticut Q 163 ��a,,\ gam. �� 2^� ►� 3 0\ NI 4` I� in R \ AC \ � r z n a \ SrV ►a '� •p J 11E� ► ,� o. (" 5 W 1 GOB T�= t Q ko L � 1 I ns Y0' t Lot lines fray sap on file in (� Twn Clerk's Office entitled, "Plot Plan / Seotion -. Pleasant Valley Hawes South Windsor, Conn." Scale 1"- 40' Dab a A-20 BONE Map wo. 220-78-10 Rey►. —` by Reino E. Hyyppa 3 Associates Glastonbury. CT. PREPARED FOR I f-weby r.ertify Wit this maa and survey were prepared ire PLEASANT VALLEY WO V ES accordance with the standards of a Class A-2 survey as defined in the existing Code of Prorti•-T fcx Standafds of Accuracy of 50UT14 WINDSOR, COON Surveys and Maps, adopted by the ConnecWA Assocish m of SCALE i"■4.0* DA,Te ?;-8-` 4 (rend Surveyors. hr. 43--1q- 4 APP_R_OVED TOWN 0:= Sr" NTH WINDSOR ENG1.''17- 71 G, D=PA 'T'f'ZNT DATE: �I /,5 7V_a ` Remo E. Hyyppa do Associates Civil Engineers Glastonbury, Connecticut J f 10 LU i 8 IFu, 0 it s, It Fnn.lc ailota l.wwro ,.\5 4 1 O JiOTE: Lot lines fray amp on file in ?own Clerk's Office entitled, "Plot Plan Section Pleasant Valley Homes South Windsor, Conn." Scale 1"- 4o' Date _ a A-20 IMNE Map No. 220-7 - J Rev. by R e i no E. Hyyppa b Associates Glastonbury, CT. pQEm%REO FOR I hr#eby certify thit this mat) and survey were prepared iii PLEA'BaNT VALLEY �40V ES accordance with the standards of a Class A-2 survey as defined In the existing Code of Pre-fl--a for Standards of Accuracy of 56 UTN W I NDSO Q, C C)w N. iurvsys and Maps, adopted by the Connecticut Association of sand Surveyors. Inc- SCARE OATe _ -S -`. 4 3 A P TOWN R DATE:---- SIG f 1 Electric # APPLICATION FOR BUILDING PERMIT Plumbing# _ 151 Jacques Lane HVAC# FDate: w—OA -(Ni Sprinkler# 900439 Estimated Cost $ 7000 FINAL APPROVALS Permit Fee $ Ion- Building COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering TYPE OF PRINT ONLY Eng. Insp. Fee $ Affidavit I I Appr.for CO. No- SIGN ON REVERSE SIDE t Total Fee $ mS TO THE BUILDING DE ARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ 3-Z-71 The undersigned hereby applies to do work according to the following: Applicant MOKKUS Location of Work 151 o E Lot No. Applicant's Address I5 TAC t Dttas LB A Tel # 0 Sag_ 5(P Town .sOt� 1.J1 m/ ,f. Zip 0 6a c)r14 Lic.# Owner \jwCCt-jT Architect Owner's Address I S 1 —JACRq�6S LA0E Architect's Address SauTk W 10.D.SDe-. Ct zip o 100,2(4 Zip Sq. Ft.New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit Of-&->VV4 q W19DdwS } � _CosA 17d 0(JS, &d rpe,rs w,n.d et)5 a re "«SS Ctv»Pl/4v7� - City Water Well ❑ Septic System ❑ Sewer❑ Ins: HO SP Area Basement Garage Approved by Date 0 - Use Group Construction Type ,k2 .1A Revised 1108 ^+���` I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in w is this building and its use is allowed. Signed /`�`' ��� C I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE _�n INSPECTION COMMENTS '(oU� •¢jZh —�5S(-- -- INSPECTION FIELD SHEET O1/26/10 Printed by Peart, Dayshell 08 43 45 INSPECTION: 26706 FOOTING PERMIT: STATUS: APPLICATION: 200901212 LOCATION: 151 JACQUES LANE SOUTH WINDSOR PROPERTY ID: 46500151 OWNER: MORRIS VINCENT R & ELIZABETH C CONTRACTOR: DESCRIPTION: REMOVE 9 WINDOWS AND REPLACE WITH 9 ENERGY EFFICIENT WORK ORDER: INSPECTOR: DOUG RESULT: N/A REQUESTED: SCHEDULED: COMPLETED: 01/13/10 UNPAID FEES 00 Date Time TIME: TRAVEL ONSITE COMMENTS ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION O1/13/10 DOUG N/A B002 FOUNDATION 01/13/10 DOUG N/A B003 FRAMING (ROUGH) O1/13/10 DOUG N/A B004 INSULATION O1/13/10 DOUG N/A B005 FIREPLACE / CHIMNEY O1/13/10 DOUG N/A B006 WOOD / GAS STOVE O1/13/10 DOUG N/A B009 OTHER 12/16/09 ROSE PASS BO10 FINAL I PK Windows LLC 952 Savage Street Southington, CT o6489 Phone# 86o 628-1173 HIC # 612970 Submitted To: Proposal Vinny&Elizabeth Morris Date: 9/30/2009 151 Jacques Lane South Windsor, CT. 06074 Estimate#: 90344 Phone: 860 528-8956 We hereby propose to f4mish all the.materials and perform all the labor necessary for the completion of the following by N6 P r ni I)f ,, 30 dOO61 (Date): Qty Description Cost Total This proposal is for Vinyl Replacement Windows. 0.00 The following windows qualify for the Federal Energy Tax Credit. 4 CertainTeed Bryn Mawr III Double Hung Windows with Fin(White) 394.00 1,576.00 1 CertainTeed Bryn Mawr III Double Hung Windows (White) 369.00 369.00 3 Harvey Majesty Double Hung Windows 586.00 1,758.00 1 Andersen Triple Casement Window 1,095.00 1,095.00 9 Special Discount -100.00 -900.00 9 Caulk 5.00 45.00 1 Misc Materials 975.00 975.00 4 Labor-Double Hung with Fin 225.00 900.00 4 Labor-Double Hung 175.00 700.00 1 Labor-Triple Casement 475.00 475.00 1 Disposal ($100 Charge-FREE) 0.00 0.00 I Permit-Town of South Windsor ***Homeowner To Pull Permit*** 0.00 0.00 Payments To Be Made As Follows: 0.00 $ 3,737.00 UPON SIGNING OF THIS PROPOSAL. 0.00 $ 3,256.00 UPON COMPLETION OF THE JOB. 0.00 The work shall include removal and proper disposal of Subtotal $6,993.00 your old window sashes. All material is guaranteed to be as specified and Sales Tax (6.0%) $0.00 completed in a substantial workmanlike manner. Total Any alteration of deviation from above specifications $6,993.00 involving extra costs, will be executed only upon written orders, and will become an extra charge over and above the estimate. All agreements contingent upon accidents or delays beyond our control. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You arena, r ¢ to o the-work as specified. Payment will be made as outlined above. Signature �j , i (� �'c �y,* (��. % r' :Z u Date Acceptance of this proposal can withdrawn within three days after signing. :; Home Improvement Contractor Signature. �,� •. I r. C,� v� s cJ, �, c '•�i�. ,c � �� J (( "t- !i -r Electric # _ APPLICATION FOR BUILDING PERMIT Plumbing# 151 Jacques Lane HVAC# Date: 'U Sprinkler# 900431 Estimated Cost $ ,000,n0 FINAL APPROVALS Permit Fee $ (r,[) Building COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering TYPE OF PRINT ONLY Eng. Insp. Fee $ Affidavit t Appr.forCO. ► SIGN ON REVERSE SIDE 4 ;01 Total Fee $ lQD— TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ -W -� The undersigned hereby applies to do work according to the following: Applicant Location of Work 1 1 Lot No. Applicant's Address t 5 AOL Tel #( $60) 52 g—g f�� awTl( (, uh ( Zip-CTown 0r7 Lic.# Owner Architect Owner's Address (S I_A A)F— Architect's A ress ��7Tt !',r Zip Zip Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit 15T FL002 f"A*11Ly (ROOM - t' E6movt:-. FXisTiy6 �ay2 ;- Cuzsc �F City Water Well 0 Septic System ❑ Sewer❑ Cons buy fiun Ins: HO S t. Area Basement Garage Approved by Date t o Use Group Construction Type I� Revised 1108�� 1 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines, side yard lines,and required distances from all other zones and is located in ich this build in .anndd tssuuse is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS 1 - INSPECTION FIELD SHEET O1/26/10 Printed by Peart, Dayshell 08:43 51 INSPECTION: 26689 FOOTING PERMIT: STATUS: APPLICATION: 200901210 LOCATION: 151 JACQUES LANE SOUTH WINDSOR PROPERTY ID: 46500151 OWNER: MORRIS VINCENT R & ELIZABETH C CONTRACTOR: DESCRIPTION: 1ST FLOOR-REMOVE EXSISTING DOOR AND CLOSE UP. REMOVE WORK ORDER: INSPECTOR: DOUG RESULT: N/A REQUESTED: SCHEDULED: COMPLETED: 01/13/10 UNPAID FEES 00 Date Time TIME TRAVEL ONSITE COMMENTS ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION O1/13/10 DOUG N/A B002 FOUNDATION O1/13/10 DOUG N/A B003 FRAMING (ROUGH) O1/13/10 DOUG N/A B004 INSULATION O1/13/10 DOUG N/A B005 FIREPLACE / CHIMNEY O1/13/10 DOUG N/A B006 WOOD / GAS STOVE O1/13/10 DOUG N/A B009 OTHER 12/16/09 ROSE PASS BO10 FINAL a ♦ v� APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074(PHONE) 860-644-2511 EXT. 230 DEPARTMENT DECISION PERMIT NUMBER: APPLICATION IS HEREBY: 19pos l � APPROVED: BLDG.PERMIT NUMBER: DATE INSPECTOR LOCATION OF WORK: APPLICANT: OWNER: TYPE OF STRUCTURE: ❑NEW BUILDING NAME F vr�r-a NAME: ADDITION : ,�P�15�\ PHONE NUMBER: 14. c k LUMBER: - EXISTING BUILDING ADDRESS: JDDRESS: r TYPE OF USE: RESIDENTIAI ❑COMMERCIAL ELECTRICAL INFORMATION: FURTHER DESCRIPTION OF WORK: TYPE OF INSTALLATION: SIZE OF SERVICE: SIZE OF MAIN SERVICE: NUMBER OF METERS: NUMBER OF PANELS: NUMBER OF LIGHT CIRCUITS: ESTIMATED COST:S NUMBER OF SWITCHES: NUMBER OF LIGHT FIXTURES: FEE ENCLOSED:S NUMBER OF A/C CIRCUITS: FEE SCHEDULE:SIS PER S1,000 OF THE ESTIMATED COST. NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS S1.00 OVER (16 CENT EDUCATIONAL FEE INCLUDED AS NUMBER OF OUTLETS: PART OF THE PERMIT FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THEW RK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE P OMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: 17 TYPE: I STATE: SIGNATURE OF APPLICANT: DATE: 0?0►90 -*x • *e� r Version#79.4-1 PIL NAS 11/01/ 19 October 31,2019 RE: CERTIFICATION LETTER �1 u / T/p''�. Q-• � tit�.•G O Project/Job#JB-0605620-00 Project Address: Narayandas Residence Z. 151Jacques Ln - No. 194 South Windsor,CT 06074 �.•�e p•:��� '•CENSrc,• AHJ South Windsor SS/ONALia' SC Office Hartford STRUCTURAL ONLY Design Criteria: -Applicable Codes=Structure:2015 IEBC w/CT Amendments;PV:2015 IBC w/CT Amendments,ASCE 7-10,and 2015 NDS -Risk Category=II -Wind Speed=125 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground Snow Load=30 psf -MP2:Roof DL=9 psf,Roof LUSL=30 psf(Non-PV),Roof LUSL=23.6 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.178<0.4g and Seismic Design Category(SDC)=B<D To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,1 certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.This inspection is required because the home was not entered and the attic structure was not reviewed prior to the structural evaluation performed for this report. Digitally signed by Jason Toman Date:2019.11.01 09:05:10-07'00' Testa,Inc. T = 5 L n ha certiti_d that t::is pl:r. vnd si,:crt,c tv.,s.,rc. .oples of the proposed building or alterations to t rected at Stree ,ogether with amtndmcnt^ st.ted in epplicution an tied with pl.•n x,d I c,r:. to ;-a:ply with all zonin. Wilding and st,t L.v,s •C cI, it.frrs as shall 1: sAued Cy If e r tic U-p-:l, nt during pendent •f this application and final issuance of a bulldin. permit. Signed his plan Is ap.rcv..d sub?e,t to tb, condition tha rtd:rs and crdita,ccs rr9ul.ttnq building shall b, :cmplicd with. :ondit ona I Appro%td These filed with Cfer R ut I'dint lttS o+r Version#79.4-1 PIL NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP2 72" 24" 39" NA Staggered 54 6% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP2 48" 20" 66" NA Staggered 6131,o Mounting Plane Roof Pitch Qualification Results (Degrees) Member Evaluation Results MP2 23 Member Impact Check OK Tesla.Inc T = 5 L n ABBREVIATIONS ELECTRICAL NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED AC ALTERNATING CURRENT POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY DC DIRECT CURRENT SHALL UST ALL EQUIPMENT IN COMPLIANCE WITH EGC EQUIPMENT GROUNDING CONDUCTOR ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY Imp CURRENT AT MAX POWER WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING kVA KILOVOLT AMPERE OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT GENERAL NOTES ALL WORK TO COMPLY WITH ALL LOCAL BUILDING, RESIDENTIAL, FIRE AND ELECTRICAL CODES MODULE GROUNDING METHOD: ZEP SOLAR REV BY DATE COMMENTS REV A NAME DATE COMMENTS t t i t t • t t 4 i i i i t i t CONFIDENTIAL- THE INFORMATION HEREIN GTISTOMER: DESC Ift CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT MA INC..NOR PREM NARAYANDAS 3.78 KW PV ARRAY T = 5 L n SHALL IT BE DISCLOSED IN WHOLE OR IN 151 Jacques Ln 3.8 KW (AC NAMEPLATE) PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS THE SALE AND�of THE RESPEccnVEWTM ( SHanwho Q—Cells Q.Peak DUO BLK G5 SC315 South Windsor, CT 6074 TESLA EOUPMENT,WITHOUT THE WRITTEN PAGE NAME: REV: DATE POUDN of TES►roc SOLAREDGE SE3800H—USOOOSNU2 COVER SHEET 10/31/2019 PITCH: 23 ARRAY PITCH:23 MP2 AZIMUTH:96 ARRAY AZIMUTH:180 MATERIAL:Comp Shingle STORY: 2 Stories PROPOSED 11/01/ 19 EQUIPMENT M LOCATION �P ��j\11.1.4M•. r�pG%s :� s • �: No.31194 J`Cnn IIII STR'�U�CTnUn„RnAuEuL�a ONLY L.Y 0- ly signed1y Jason Toman o (E)DRIVEWAY Date2019.11009:0539-07 00' LEGEND (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISC O .,SS/ONAI " & WARNING LABELS © DC DISCONNECT & WARNING LABELS I I © AC DISCONNECT & WARNING LABELS I I 1 DC JUNCTION/COMBINER BOX & LABELS I I ll �° DISTRIBUTION PANEL & LABELS u, m Iul LL ® LOAD CENTER & WARNING LABELS Ip0 MI M DEDICATED PV SYSTEM METER O RSD RAPID SHUTDOWN 0 STANDOFF LOCATIONS Front Of House I I CONDUIT RUN ON EXTERIOR I I --- CONDUIT RUN ON INTERIOR I SV GATE/FENCE I 0 HEAT PRODUCING VENTS ARE RED i I INTERIOR EQUIPMENT IS DASHED L='J F— r I 3' FSB J 3' FSB SITE PLAN N Scale: 1/8" = 1' W E 0 1' 8' 16' S COWDENTIAL— THE INFORMATION W" DESCRPDON: CONTAINED SHALL NOT USED FOR THE 3.78 KW PV ARRAY T = 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTDk SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—insert 3.8 KW (AC NAMEPLATE) PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANISALVE AND EXCEPT OTF IN RREN�CnavEwTM ( SHanwha Q—Cells # Q.Peak DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME PErdASSIDN OF TESLA INC. SOLAREDGE SE380OH—USOOOSNU2 SITE PLAN S1 (N) PV MODULE (E) MOUNTING PLANE (MP) sv TYPICAL PV SIDE VIEW NTS PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER 11/01/ 19 INSTALLATION ORDER / ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE C7JV ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT �`�.•••q'M i,ih'••. HOLE. �,'�Q.o��„ ,� �o•G•►', ZEP MOUNTING BLOCK ATTACH FLASHING INSERT TO E2) MOUNTING BLOCK AND ATTACH ,o': No.31194 ` ( ) TO RAFTE ZEP FLASHING INSERT 3R USING LAG SCREW. %9'•.�, a •��, (E) COMP. SHINGLE ----%OFF ••�ENS�• (1) INJECT SEALANT INTO FLASHING %SS�ONAI.EN���`` (E) ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS STRUCTURAL ONLY SEALANT EVENLY OVER THE 5/16" DIA STAINLESS ROOF PENETRATION. STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES (2-1/2" EMBED, MIN) INSTALL LEVELING FOOT ON TOP [(4) OF MOUNTING BLOCK & (E) RAFTER S1 STANDOFF SECURELY FASTEN WITH BOLT. Scale: 1 1/2" = 1' CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE T SI L n BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEY: SHALL IT BE DISCLOSED IN TMiOLE OR IN ZS Comp V4 w Floshin —Insert PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME: PERIASSION OF TESLA INC. FSTRUCTURAL VIEWS Jobsite Specific Design Criteria Design Code ASCE-7_10 11/01/ 19 Importance Factor 1 1 Ultimate Wind Speed V—Ult 125 Fig. 1609A yo�, ►M Exposure Category C Section 26.7 No.31194 Ground Snow Load pg 30 Table 7-1 ' °�F STRUCTURAL ONLY MP Specific Design Information MP Name MP2 Roofing Comp Shingle Standoff ZS Comp V4 w Flashing—Insert Pitch 23 SL/RLL: PV 23.5 psf SL/RLL: Non—PV 30.0 psf Standoff Spacing and Layout MP Name MP2 Landscape X—Spacing 72" Landscape 24" X—Cantilever Landscape Y—Spacing 39" Landscape _ Y—Cantilever Portrait X—Spacing 48" Portrait X—Cantilever 20" Portrait Y—Spacing 66" Portrait Y—Cantilever — Layout Staggered X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters. CONMENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC..NOR MOUNTING SYSTEM: T � 5 L In SHALL IT BE DISCLOSED IN WHOLE OR IN ZS CompV4 w Flashing—Insert PART TO OTHERS OUTSIDE THE RECIPIENTS ON WI ORGANIZATION. EXCEPT IN CONNECTITH THE SALE AND USE OF THE RESPECTIVE TESLA EOUPMENT. WITHOUT THE WRITTEN PAGE NAME: PEA SSION OF TESLA wG UPLIFT CALCULATIONS ROUND WC9 INVERTER SPECS MODULE SPECS BOND GEC TO ELECTRODE AT PANEL WITH -(1)SOLAREDGE_I SE38OOH—US000SNU2 -(12)Honwho 0-Cells O.Peak DUO BLK-G5/5C315 IRREVERSIBLE CRIMP Inverter W.240V/208V,99%HD Wave w/Unifed Disco and ZB,AFCI PV Module; 315W.292.2PTC,40MM. Black Frame,MC4,ZEP,1000V VOC: 40.29 Vpmox: 33.46 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER F)MAIN SERVICE PANEL RATED FOR CODA MINIMUM , Inverter 1 (E) MAIN CIRCUIT BREAKER RATED FOR 100A MINIMUM ------------ AC DISCONNECT 2 SOLAREDGE MAIN BREAKER SE3800H-USOOOSNU2 (E)LOADS j A Ll Zgov • L2 • N 20A/2P -----------—-----------—----------- ---- GND - -EGCI -- DC- 1 DG 3) 1Dr-A I GEC DC- 1x12 B iI I A_1�3j -- EC—'C--------------------------------------- EG—C------------------� I I I I I I N 1 I I EGCIGEC — I o --- 1 Z z 1 {is l,.L 1 ihis certifi;d th,t t:.;s pi in anu si,c CHIC.tIf:,S Jf@ tl ——— GEC —_ iaples of the proposed building or alterations to t erected at TO 120/240V SINGLE PHASE 1 I Stree UTILITY SERVICE 1 I together with amendmr•ntz St t:d in application an 1 riled with plan znd i cgre< tO ".nply with all zonint 1 I 31jilding and tt.tn laws air.: cl._h girders as shall b I issued by the ;;.ildinq U ,p1,t;.rnt during pendene I I ,f this application and final Issuance of a buildin. I �— permit. --------------_-J Signed rhis plan is aparavrd sublect to ti. condition the ZTHE FOLLOWING PAGE INCLUDES ALTERNATE CODE COMPLIANT TIE—INS, IN ADDITION TO THIS PAGE. � and ordin jr ccs r¢�utjting buiL4eng aheFl b. :ornmpliplied with. SITE SPECIFIC CONDITIONS TO DETERMINE WHICH CODE COMPLIANT TIE—IN WILL BE INSTALLED. :onUitloIly d,r d These filed wish Ruilding InspcctQl V�-r•i,.; METER IS TOP FED j CI{ Voc* = MAX VOC AT MIN TEMP Ol (1)PV BACKfEED BREAKER— 20A A (1) Disconnect; 30A.24OVac,Non—Fusible,NEMA 3R /t, PV 02)SOLAREDGE j P40D-5NM4MZM —(1) Ground/Neutrd Kit; 30A, General Duty(DG) A PowerBox OPtmizer,40OW,ZEP DC MIN CONDUCTOR SIZE MAX VALUES 1 AWG/10. THWN-2.Block 2 AWG 010,PY Wire, 60OV.Blade Voc* =500 VDC Isc=15 ADC O (1)AWG/10. 7HWN-2.Red O (1)AWG 110. THNN/THWN-2.Green EGC VmP =350 VDC Imp=10.66 ADC LLL���1LL(1)AWG/10,THWN-2,White NEUTRAL VmP =240 VAC Imp= 16 MC (1)Conduit Kit;.3/4'.EMT. —,(1)AWG/8.,TH,WN-2.,Green EGC/GEC-(1)Conduit,Kit;,3/4',EMT. CONFIDENTIAL— THE INFORMATION HEREIN D5WTIOR CONTAINED SHALL NOT BE USED FOR THE 3.78 KW PV ARRAY �' `i BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR 5 L n SHALL IT BE DISCLOSED IN WHOLE OR IN 3.8 KW (AC NAMEPLATE) PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT THE SALE AN USE HE E ( Hanwho Q—Cells # Q.Peak DUO BLK—G5/SC315 TESLA EQUIPMENT. WITHOUT THE WRITTENINVERTElt PAGE NAME: PERMISSION OF TESLA INC. SOLAREDGE SE380OH—USOOOSNU2 ELECTRICAL LINE DIAGRAM THIS SHEET INCLUDES ALTERNATE CODE COMPLIANT TIE—INS, IN ADDITION TO THE PREVIOUS SHEET. LICENSE FIELD CREW TO DETERMINE WHICH CODE COMPLIANT TIE—IN WILL BE INSTALLED. CA 18881D4 C-10 BREAKER BACKFEED AND RELOCATED LOAD(S) IN BREAKER BACKFEED IN NEC COMPLIANT SUPPLY SIDE CONNECTION WITH DISCONNECTING MEANS LOAD SIDE TAP WITH DISCONNECTING NEW NEC COMPLIANT DISTRIBUTION PANEL DISTRIBUTION PANEL SUITABLE AS SERVICE EQUIPMENT AND RATED PER NEC MEANS PER NEC (E) MAIN SERVICE PANEL RATED FOR 100A MINIMUM (E) Distribution Panel (( ) MAIN SERVICE PANEL RATED FOR 100A MINIMUM (E) MAIN SERVICE PANEL RATED FOR 1DOA MINIMUM (E) 6 OR FEWER MAIN DISCONNECTS (N) Load Center (E) MAIN E) 6 ORE PANEL RATED FEWER MAIN DISCONNECTSFOR100AMINIMUM (E� MAIN CIRCUIT BREAKER RATED FOR 100A MINIMUM (E) 6 OR FEWER MAIN DISCONNECTS g (E) LOADS AC DISCONNECT AC DISCONNECT � 4 (E)LOADS B 20A/2P (E) LOADS g2P B 20A B 20A A T A LLL i • e (E) LOADS B NEUT (E) LOADS • r — JA B 1 I = I I I G B 1GM J I 1 1 �J 1 • I 1 I 1 1 1 N I N 1 N I N 1 I 1 1 1 (E) LOAD EEC 1 EGGGEC — EGGGEC _j GClG o --- ----j o --- --- • z z z z I z z --- C —_Y --- GEC ---♦ --- — GECt ----GEC GE _f I • I I 1 I I t 1 I NEUT TO (E) LOADS I I I I 1 1 I 1 (E) Distribution Panel I 1 1 1 I I I 1 BREAKER FEEDING DISTRIBUTION PANEL BREAKER FEEDING DISTRIBUTION PANEL BREAKER FEEDING DISTRIBUTION PANEL AND DISTRIBUTION PANEL RATING TO COMPLY AND DISTRIBUTION PANEL RATING TO COMPLY AND DISTRIBUTION PANEL RATING TO COMPLY WITH NEC 705.12 WITH NEC 705.12 WITH NEC 705.12 POI B (1)PV BACKFEED BREAKER—20A POI (z)ILsco t'�4/0—'6 POI (2)LSCO I PC 4/0—o y �p haul.ion Piercing Connector, Main 4/0-4. Tap 6-14 Insulo ion Piercing Connector, Main 4/0-4.Tap 6-14 —(2)BMu tFl �eT Lo nector, 2 Port B (1) Disconnect 60A, 24OVoc,Fusible,NEMA 3R B (1) Disconnect; 30A.24OVac,Fusible,NEMA 3R B (1) Load Center, 120/24OV,NEMA 3R —(1) Ground/Neutrd Kit; 60-100A, General Duty(DG) —(1) Ground/Neutral Kit; 30A, General Duty(DG) —(1) Breaker, 20A/2P. 2 SpacesPV BACKFEED BREAKER —(2)FFuse ReducSHAMUer 0 R632 —(1) Class R Fuse Kit Fuse Reducer, 3DA Fuse for 60A Clip, 250V —0) pass R Fuse Kit —(2)FERRAZ SHAWMUTT TR20R PV BACKFEED DCP —(2)FERRAZ SHAWMUTT#TR20R PV BACKFEED OCP Fuse; 20A.25OV, RK5 Fuse; 20A,25OV, ass RK5 r� 1 AWG J6, THWN-2.Block 1 AWG#10.TIM-2.Block (1)AWG/6, THWN-2,Red ®LL(1)AWG/10.THWN-2.Red �L(1)AWG/6,THWN-2,White NEUTRAL �L(1)AWG#10.THWN-2,White Neutral —(1)AWG/6.Solid Bore Copper GEC —(1)Conduit Kit; 3/4'EMT (1)AWG it THWN—$Green EGC/GEC (1)Conduft Kit; 3/4'EMT CONFIDENTIAL— THE INFORMATION HEREIN DESCRIPTION: CONTAINED SHAM NOT BE USED FOR THE 3.78 KW PV ARRAY BENEFISTALL IT OF DISCLOSED EXCEPT OLEiE DR N NOR 3.8 KW (AC NAMEPLATE) PV ARRAY T = 5 L n PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT. WITHOUT THE WRITTEN PAGE NAME FISSION OF TESLA INC. ALTERNATE ELECTRICAL TIE-IN METHODS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 151 Jacques Ln 1 1 I 1 I I I 1 I I I I 1 I 1 1 I 1 �J I I I I LJ AC DISCONNECT UTILITY SERVICE UTILITY SERVICE INVERTER �------------------------- -j I SOLAR PHOTOVOLTAIC ARRAYS) I L--------------------------J PHOTOVIOLTAIC BACK-FED aRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0605620-00 CONFIDENTIAL- THE INFORMATION HEREIN LLSCRIPTIOK CONTAINED SHALL NOT BE USED FOR THE 3.78 KW PV ARRAY T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC..NOR MOUNTNG SMEI& SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—insert 3.8 KW (AC NAMEPLATE) PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION.EXCEPT IN CONNECTION WITH MOOUIES: THE SALE AND USE OF THE RESPECTIVE (12) Hanwha Q—Cells # Q.Peak DUO BLK—G5/SC315 TESLA EQUIPMENT.WITHOUT THE WRITTEN IIVER7m PAGE NAME PERMISSION OF 7ESLA INC: SOLAREDGE SE380OH—USOOOSNU2 SITE PLAN PLACARD WARNING:PHOTOVOLTAIC POWER SOURCE Label '- Location: ' ' Location: Label Location: . 'B WARNING '' '• WARNING ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD Per Code: Per Code: Per Code: NEC 690.31.G.3 DO NOT TOUCH TERMINALSNEC •• TNEC HE DC CONDUCTORS OF THIS '• Label • _ • TERMINALS ON BOTH LINE AND �'HOTOVOLTAIC SYSTEM ARF TO BE USED WHEN LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND PHOTOVOLTAIC DC D INVERTERIS IN THE OPEN POSITION RAY BE ENERGIZED UNGROUNDED DISCONNECT Code: NEC .•0 Label • • Label j Location: PHOTOVOLTAIC SYSTEM MAXIMUM POWER- a U (INV) Per Code: POINT CURRENT(Imp)_ Per Code: SHUTDOWN .• NEC MAXIMUM POWER- �. •• 0.53 POINT VOLTAGE(Vmp) Label Location: MAXIMUM SYSTEM �, VOLTAGE(Voc) SHORT-CIRCUIT CURRENT(Isc) WARNING '• Per ..- NEC INVERTER OUTPUT CONNECTION 690.64.B.7 •-1 Location: DO NOT RELOCATE WARNING Per THIS OVERCURRENT DEVICE •••- NEC ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED •• NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED abel Location: CAUTION '_ Code: PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 690.64.B.4 Label • • Per Code: WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALSNEC 690.17(4) Label Location: OAD SIDES MA BBE ENERGIZED CAUTION IN THE OPEN POSITION DUAL POWER SOURCE Per ••- SECOND SOURCE IS DC VOLTAGE IS I'HOTOS�(�LTAIC SYSTEM NEC 690.64.B.4 ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • PHOTOVOLTAIC POINT OF �• •- • • INTERCONNECTION _ Code: PHOTOVOLTAIC AC '• WARNING ELECTRIC SHOCK ••, 690-54 Disconnect HAZARD DO NOT TOUCHNEC DISCONNECT Per Code: TERMINALS.TERMINALS ON Conduit NEC •' BOTH THE LINE AND LOAD SIDE • • • MAY BE ENERGIZED IN THE OPENDistribution (DC): DC Disconnect POSITION FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER MAXIMUM AC A •-1 Locatio • - • Integrated - • • • ' '•I -• - A ,• Center OPERATING CURRENT •. Code OPERATING CURRENT (M): Utility Meter MAXIMUM AC h1AXIh9UM AC OPERATING VOLTAGE _ V 690.54 OPERATING VOLTAGE _ V '• Point of • • `i�SoiarCity/ ®pSOlar Next-Level PV Mounting Technology "j'SOiarcity ®pSOLar Next-Level PV Mounting Technology ZS Comp Components for composition shingle roofs � o� 0 Mounting Block Array Skirt Interlock Part No.850-1633 Part No.850-1608 or 500-0113 Part No.850-1388 or 850-1613 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 s � Flashing Insert Grip Ground Zep V2 Part No.850-1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 Ow. Description PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules COMPOI Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Captured Washer Lag End Cap DC Wire Clip U� LISTED Part No.850-1631-001 Part No. Part No.850-1509 Specifications 850-1631-002 (L)850-1586 or 8%1460 Listed to UL 1565 850-1631-003 (R)850-1588 or850-1467 • Designed for pitched roofs 850-1631-004 Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices fp� Leveling Foot Part No.850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services-Zep Solar's sole warranty is contained in the written product warranty for This document does not create any egress warranty by Zap Solar or about its products or services-Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for venfying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps zspats.com responsible for venfying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps zspats.com. Document#8W1839-001 Rev D Date last exported:April 29,2016 11:22 AM Document#800-1839-001 Rev D Date last exported:April 29,2016 11:22 AM • solar=9e solar=@@SolarEdge Power Optimizer - Zep Compatible TM Module Add-On For North America P400-ZEP SolarEdge Power Optimizer — P3WUP(tWN-allwmodWa) P400-ZEP ft72Bk96W1moetdW INPUT Rated Input DC powerl'i 300 400 W Zep Compatible r"" Module Add-On Ae�l1MaximiimI..rap R.�*o. .age.....N..oc..at...lowe.......s.t..... .................. ........................... ...................................... . 48 80 . ...... ....vac..... temperature) .............................................. ............................................... ............................................... .............. For North America P300-ZEP, P400-ZEP Mir gpera gRange 8-4s 8so Vdc _ Maximum Short Circuit Current..... 10 10.1 Adt Maximum DC Input Current 12 5 12.63 . Adc . ..... ....... . ........ .. ..... .... .. .. .... . ... ..... . ...... . .... . ...... ... .................. ... MaximumEtficien�X....................................... ............................................. :5............................................. .....%.-.... • Weighted ... . !envy.................................... _..................................9 .. ........... % Overvoltage Category 11 OUTPUT DURING OPERATION(POWER OPTI M I Z ER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) _ Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE • ..E.MC..... .................................................... ...................FCC.P..a.r.t.1..5..C..la..s.s..B.,..I.E.C..6.10.00-.62.,.IEC6.10.00-6...3 .................. ....... ... ... ..... .. .. Safety IEC62109-1(dass 11 safety),UL1741 ................................................................. ............................................................................................... .............. RoHS Yes INSTALLATION SPECIFICATIONS 25w� Maximum Allowed.System voltage.................. .. ....... 1000 Vdc ...... ..................................... ............................................... ......... W / Dimensions including mounting bracket (WxLxH) 129 x 1%x 27.5/5 x 7.71 x 1.09 128 x 196 x 35/5 If 7.71 x 1.37 mm/in ........................ .......... ...........�.... ... ............................................... ............................................... .......�..... Dimensions excludingmounting bracket xLx.. 128 x 152 x 27.5/5 x 5.97 x 1.08 128 x 1.52 x 35/ mm in Sx5.97x1.37 (I ...................................................... _............._.._.......................... ............................................... .............. Weight ndudirtg cables and mounting bracket)..... ..................720/1;6...............I.. ..................840/1.9.................. ...k1 Ib Input Connector MC4 Compatible Output Connector Double Insulated:MC4 Compatible Output Wire le^�t1!....................................... .................0.95/3.0.................1...................1.2/3.9.................. m/.ft.... Operating Temperature Range 40-+85/-40-+185 C/•F .....................I.......I........_ ..................._..... ............................................................................................... .............. Protection Rating IP68/NEMA 6P Relative Humidi 0-100 %. W Rated SFC power of the module.Module of up to S%power tolerance allowed PV SYSTEM DESIGN USING A T SINGLE PHASE THREE PHASE THREE PHASE SOLAREDGEINVERTEVI HD-WAVE SINGLE PHASE 208V 480V Minimum String Length(Power Optimizers) 8 10 18 Compatible with Zep Groove framed modules MaximumStringlength(PowerOptim----- 25 25 50 _. ._. .. Maximum Power per String 5700(6000 with 52SO 6Wo 127SO W SE7600H-US) "' _ I from __.....__._.._.... ............ .. . ..... ......................... ......._. . . .....I............. Certified Zep Comparable bracket Mitigates all types of module mismatch losses, o — Attaches to module frame without screws-reduces on-roof manufacturing tolerance to partial shading Parallel Strings of Different Lengths or Yes labor and mounting costs — Flexible system design for maximum space utilization Orientations MFa deftkd sting s,r g,,formaba rekr to'hftp'./Aw sot aredge com/sites/default/files/string sexing na pdf — Power optimizer equipment grounded through the bracket — Next generation maintenance with module-level monitoring — Up to 25%more energy Module level voltage shutdown for installer and firefighter ' safet Superior efficiency(99 5%) N y ± USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-HUNGARY-BELGIUM-ROMANIA-BULGARIA www.solaredge.us powered by SPECIFICATIONMECHANICAL DUO Format 66.3in x 39.4in x 1.57in(including frame) 0685mm x 1000mm x 40mm) Weight 44.51bs(20.2 kg) ..,.. ,,°,,,.� From Corer 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology •�°"%� Bach Cover Composite film Frame Black anodized aluminum .� ® Cell 6 x 20 monocrystal line Q.ANTUM solar half-cells _0 Junction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83in (70-85mm x 50-70mm x 13-21mm),decentralized,IP67 Cable 4mm2 Solar cable;(+)z43.3in(1100mm),(-)z43.3in(I100mm) waH-.o Connector Multi-Contact MC4,IP68 ELECTRICAL CHARACTERISTICS Q, PEAK DUO 310-3201 POWER CLASS 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-OW) Power at MPP= Pry, IW] 310 315 320 SOLAR , e MODULE Short Circuit Current' Is, [A] 9.83 9.89 9.94 so Open Circuit Voltage' Vk IV] 40.02 40.29 40.56 Current at MPP' I_ [Al 9.36 9.41 9.47 Voltage at MPP' V,r„ IV] 33.12 33.46 33.80 The new Q.PEAK DUO BLK-G5/SC solar module from Q CELLS impresses Efficiency' r) 1%] z18.4 a18.7 z19.0 thanks to innovative Q.ANTUM DUO Technology,which enables particularly MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOW high performance on a small surface,and a black Zep CompatibleTM frame Power at MPP' P_ IW) 229.7 233.5 237.2 design for improved aesthetics, easy installation and increased safety. E Short Circuit Currant' lu [A] 7.93 7.97 8.02 Open Circuit Voltage' V. IV] 37.43 37.69 37.94 UNTUM s world-record-holding cell concept has now been combined Current at M►P' 11- [A] 7.36 7.41 7.45 with state-of-the-art circuitry half cells and a six-busbar design, thus Voltage atMPP' VW IV] 31.20 31.52 31.84 achieving outstanding performance under real conditions - both with �IDOOWImr.25C,spectrum AM 1.5G Measurement tolerances STC13%;NOC t 5% 3800W/m2,NOCT,spectrum AM 1.513 'typical values,actual values may differ low-intensity solar radiation as well as on hot, clear summer days. 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE hi6 Al least 98%of nominal power during first year. +�11p --T----- -----' -----'---- Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY Thereaftermax.0.54%degradation`9 . Per Year.--�---- At least 93.1%of nominal power up to 10 years. n G Higher yield per surface area, lower BOS costs, higher power At least 85%of nominal power up to 25 years. classes,and an efficiency rate of up to 19.3/d. o �g e All data within measurement tolerances. a E Full warranties in accordance with the warranty INNOVATIVE ALL-WEATHER TECHNOLOGY terms of the u CELLS sales organization of your respective country. ro < Optimal yields,whatever the weather with excellent low-light b xa taxAolruraWien � and temperature behavior. Typical module performance under low irradiance conditions in comparison to STC conditions(25°C,1000W/m'). ENDURING HIGH PERFORMANCE QUELLS ••,,•"'+'•,"e...,�,.,or.„...,...,.,�r. � 1 'g TEMPERATURE COEFFICIENTS R I1I Long-term yield security with Anti LID and Anti PID Technology', �t;-18 ANDPV Temperature Coefficient of I„ a [%/K] +0.04 Temperature Coefficient atV. p [%/K] -0.28 d Hot Spot Protect and Traceable Quality Tra.QTMt. Temperature Coefficient of P,,,, v [%/Kl -0.37 Normal Operating Call Temperature "OCT ['Fl 113 t5.4(45 s3°C) Y EXTREME WEATHER RATING f• I DESIGN 0 High-tech aluminum alloy frame, certified for high snow Maximum System Voltage VAR IV) 1000(IEC)/1000(UL) Safety Class II (5400 Pa)and wind loads(4000 Pa) regarding IEC. GOMPA77 Maximum Series Fuse Rating [A OC] 20 Fire Rating C(IEC)/TYPE 1(LIL) Ci �Q ��� Design load,push(UL)' [lbs/Wl 50(2400Pa) Permitted module temperature -40°F up to+185°F A RELIABLE INVESTMENT on continuous they (-40°C up to+85°C) a O Inclusive 12-year product warranty and 25-year , j 4 Design load,pull(UL)2 Obs/fN) 50(2400Pa) 'see installation manual Fp v linear performance guarantee2. cpMpp( QUALIFICATIONS r CERTIFICATES PACKAGING INFORMATION UL 1703;CE-compliant; Nearhaf of MadWes por pallet 26 t STATE OF THE ART MODULE TECHNOLOGY IEC 61215(Ed.2);IEC 61730(Ed.1),application class A s Q.ANTUM DUO combines cutting edge cell separation ' APT test conditions according to Number of Pallets par 53'Trailer 32 I EC/TS 62804-1:2015, SA e �` 4F Number of Pallets per 40'Nigh Cuba Container 26 s and innovative wiring with Q.ANTUM Technology. method B(-1500V,168h) pVE Pallet Dimension 0.ione x W x N) 69.3in x 45.3in x 46.9in See data sheet on rear for further ` C U bus ?.O` (1760mm x 1150mm x 1190mm) THE IDEAL SOLUTION FOR: information. = Pallet Waight 1268lbs(575kg) Y NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use ®Rooftop arrays on of this product. ommerdal/industrial buildings NamMa G CELLS America lac. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiryOus.q-cells.com I WEa www.q-cells.us Engineered in Germany OCELLS solar=@o Single Phase Inverters for North America solar=@@ SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/SE760OH-US/ SE10000H-US/SE1140OH-US SolarEdge Single Phase Inverters OUTPUT SE3000H-US 00R SE38 -US SES000H US j SEGUIN-US 00H- SE76US SE1000011-US SE1140OWUS _ 38W @240V Rated AC Power Output 3000 5000 6000 7600 30000 11400 VA for North America 3800@240V.. .... Max.AC Power Output 3000 S000 6000 7600 10000 11400 VA ..............Win.,46in....... ................. .3300.�208V.. SE3000H-US / SE380OH-US / SE5000H-US/ SE6000H-US / M outputVokageMin:Nom: Of W� SE760OH-US/ SE1000OH-US / SE1140OH-US Max,.(ia3.-�o geMi.............. .......�..... ✓...... .......�....... .......�....... .....-.✓....... . ......�....... . ......✓.- .. . ...Vac.... At Output Voltage Min:Nom: .•.......... .. ....... ......... ................. ................ ................ ................ ................. ................. ........... AC Frequency.(Nominal)............ ....... .... ... ................. ... ...........59.3-60-60,S111 H?..................... ................. ................. . Maximum Continuous Output Current 208V 16 24 A Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current240V........................ ................. .................I................ ................ ..-........-.... .-............... ................. ........... GDIThreshold...................... .............................................................1........ A Utility Monitoring,Islanding 4 �g �� V� `z to srt+ Protection,Country Configurable Yes 12,25', Thresholds ,I,ya INPUT Ws Maximum DC Power 46SO 5900 7750 9300 11800 15500 17670 W .._: ............................. ................. ................. ................ ................ ................ ........... ..... .. .............. ........... +,�.•``'' Transformer-less,Ungrounded Yes Maximum Input Voltage............ .. ................................480 Vdc . .... e N No-* DC input Voltage. 380 400 Vdc ........... ................. ..... ............... ................ ................. • - Maximum Input Current 208V 9 13.5 . .......ig ....... ......."........ Maximum Input Current.240V 8.5 10.5 13.5 1 .5 20 27 305 Adc 10.S .. . ......... .... . ................1: :: ::.-: : ::1 :: : :: :::: :: Max.Input Short Circuit Current Adc .... .......................................................................................................................... ........... Reverse Polarity Protection Yes ........................................................... ........... Ground Fauk Iwlation Detectbn 600ko Sensitivity • Maximum Inverter Effici e^cY........ .......99....... .................. ............................... :?.................................................. ....76..... • CEC Weighted Efficiency•..,. _.,_, 99 % Nighttime Power Consum n <2.5 W ADDITIONAL FEATURES s e Supported Communication Interfaces R5485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,AN51 C12.20 Optionallzl ........................................................ ....................................................... ........... Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect e STA ARD COMPLIANCE safety.._.. UL1741,UL1741 SA,UL16998,CSA C22.2,Canadian.AFC according to T,I.L,M-07 ........... ............................................. .......... S Grid Connection Standards.. ... . IEEE1547,Rule 21,Rule 14(HI)........ ..................... .......... . ..... Emissions FCC Part 15 Class B __INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG .ARan a 3/4"minimum/20-4 AWG mIll....................... ...................................................................................... ................... ... ........... DC Input Conduit Size/0 of Strings 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ /.AWG Range........................ . 14-6 AWG............ Dimensions with Safety Switch 21.3 x21.3 x 14.6 Optimized installation with HD-Wave technology (HxWxD) 17.7 x 14.6 x 6.8 /450x370x174 x7.7/540x x7*3/540x in/mm Specifically designed to work with power optimizers 370,x.195.,. „.370.x.185,., ........... Weight with Safety Switch 22/10..........•... 25.1/11.4 I 26.2/11.9........... ..38.8./17.6 40.1/18.2 Ib(,kg Record-breaking efficiency Notre I......... <25 <50 dBA Fixed voltage inverter for longer strings Cooling Natural Convection Natural corn al fan(user convection and intern .... ... .......... ................ ........... ...... replaceable)..... ............. ........... Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 Operating Temperature Range...... ........................... .......-13to+140/-25 to.+6ph1(-4p'F/-40'Copt pn"I..... 'F/'C. Protection Ratin6 „ „ ,.,,. ,•, NEMA 3R(Irnrerter wKh Safety 5wttch)...,., UL1741 SA certified,for CPUC Rule 21 grid compliance f. - i - .• pr For other regional settings please contact SolarEdge support Extremely small Revenue gr,de.n-n,,P/N.SEs H-US000NNQ NI For power de rating information refer to'.https://www.solaredge.wm/sites/defy tt/Bles/sete nperature-&crating-rwte-na.pdf High reliability without any electrolytic capacitors V ,�' R -00 ve sion P/N SEscxzH USOODNNW Built-in module-level monitoring 11111111111', - Outdoor and indoor installation "'I""'I/G v e Yc - Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) - Simple configuration and commissioning with smartphone app and built in Wi-Fi(SE10000H-US,SE11400H-US) • USA CANADA GERMANY UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRAUA-ISRAEL-FRANCE-BELGIUM TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY-SWEDEN www.solaredge.u5 SOUTH AFRICA-POLAND-CZECH REPUBLIC Electric # APPLICATION FOR BUILDING PERMIT Plumbing# HVAC# Date: Sprinkler# Q Estimated Cost $ FINAL APPROVALS Permit Fee $ Building COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit Appr.for CO. No,- SIGN ON REVERSE SIDE t Total Fee $ TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant )nGlICEWLocation of Work Lot No. Applicant's Address Tel # Town Zip 4c.# A41' ' Owner Architect Owner's Address Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit City Water J Well J Septic System J Sewer J Ins: HO SP t. Area Basement Garage Approved by FIT Date Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any a&,ande e pla s or specifications of the Building for which this permit is asked,and agree that this building is to be locateist ce from all street lines, side yard lines,and required distances from all other zones and is located in which this se is allowed. SignedI hereby apply for a Certificate of Occupancy forcrib in this application for the permit. Signed DO NOT WRITELINE INSPECTION COMMENTS INSPECTION FIELD SHEET 02/22/21 Printed by Middleton, Morgan 14 36 27 INSPECTION: 124136 FINAL PERMIT: STATUS: APPLICATION: 201902620 LOC: 151 JACQUES LANE SOUTH WINDSOR PROPERTY ID: 46500151 OWNER: NARAYANDAS PREM & CONTRACTOR: REQUEST BY: PROJ DESC: INSTALL 12 ROOF MOUNTED SOLAR PANELS 3.78KW WORK ORDER: INSPECTOR: ROSE RESULT: PASS REQUESTED: PRIORITY: SCHEDULED: 01/22/20 03 00 COMPLETED: 01/23/20 UNPAID FEES 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS: ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 01/23/20 ROSE PASS E010 ELECTRIC FINAL RELEASED TO EVERSOURCE CRS# 3356516 /l/23/20 1900875 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 1 I/22/2019 GIS ID:46500151 FEE: 90.00 MUNIS APPLICATION# 201902620 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: SOLARCITY ADDRESS: 151 JACQUES LANE ADDRESS: 714 BROOK STREET OWNER: -NARAYANDAS PREM& SUITE 150 "" 151._JACQUES LANE ROCKY HILL,CT 06067, DESCRIPTION OF WORK: INSTALL;12 ROOF MOUNTED SOLAR PANELS 3.78KW SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH TI IE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 11/22/2019 2:09 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1900512 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 11/22/2019 GIS ID:46500151 FEE: 198.00 MUt4IS APPLICATION# 201902620 BUILDING DESCRIPTION: APPLICANT,; LOCATION NAME: SOLARCITY ADDRESS: 151 JACQUES LANE ADDRESS: 714 BROOK STREET,"' OWNER: NARAYANDAS PREAI& SUITE 150 151 JACQUES LANE-, ROCKY HILL,CT 06067 DESCRIPTION OF WORK: INSTALL 12 ROOF MOUNTED SOLAR PANELS 3.78KW f SPECIAL CONDITIONS: ALL, WORK TO BE DONE IN ACCORDANCE W1T1I THE APPLICATION'AND PLANS APPROVED BY THE BUiLmD G DEPARTMZNT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 11/22/2019 2:10 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1000009 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 01/13/10 GIS ID:46500151 ti FEE: 15.00 MUNIS APPLICATION# 201000033 'BUILDING DESCRIPTION: J APPLICANT,,,APPLICANT,I,i LOCATION NAME: MORRIS VINCENT R ADDRESS: 151 JACQUES LANE ADDRESS: 151 JACQUES LANE .�' .��; s' OWNER: MORRIS VINCENT R&ELIZABETH C SOUTH WINDSOR,CT 06074 , 151 JACQUES LANE } _ SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: VENT FREE GAS LOG HEATER SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: µ OCCUPANCY GROUP: BUILDING OFFICIAL 1/13/2010 10:42 AM THE FEE ABOVE INCLUDES A$0.16 PER THOUSAND CT STATE EDUCATION SURCHARGE