151 BERLE RD
,� 3 �13 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: �� BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# � Elate Building Inspecty Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT At e Ilkme Sete V I C e-S APPLICANT ADDRESS 0,61L60 APPLICANT PHONE# O W N S F,q OWNER 'S nn \L -e I R- C OWNER AD RES LAId-SOX, C C07O b OWNER PHONE C ESTIMATED COST$ � �. 00 4 IS THIS A CONTRACT COST? X-Yes _No FEE ENCLOSED$ Z Qj VV TYPE OF JOB: \\nn SO R•C0 _New Installation �dv� XAlteration/Addition/Repair Revised 4/01//2002 I APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE F YSTEM: TYPE OF UILDING: HEATING RESIDENTIAL ❑A/C 9COMMERCIAL O VENTILATION ❑ INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(BEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL A ING EQUIP NT C UDIN &MODEL NO.) AIAC ' u P P A " S GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION :❑INSIDEO OUTSIDE CAPACITY ❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) / FURTHER DESCRIPTION OF WORK /�P 4c e m.J ` THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. a cS-/ ff CONTRACTORS LICENSE NO. STATE Q� SIGNATURE OF APPLIC TYr DATE O © O AFELL16 CORPORATE OFFICE PO. BOX 548, WINDSOR LOCKS, CT 06096 Plumbing • Heating Electrical Air Conditioning Quality Solu tions SERVICES 8 To Whom This May Concern: Aiello Home Services authorized Linda Dawson-Hayes, Russell Horrocks, Stephen Birch, Garrett Cardwell, Dave Arildsen,Tim Lynch, Joe Sparveri, Keith Tyler, Randy Weidig, Shawn Greenlaw to pull permits for our company for any plumbing, heating or air conditioning replacement(s) or new installation(s). If you have any questions please call our office at 860-292-2600. This letter is for a permit for the property located at: 6� o'14 Homeowner: cJim �- [P�OACiA O 'M f40,& Permit Fee Amount: $ r Sincerely, Mic ael Jezouit President STATE OF CONNECTICUTOF CONNECTICUT DEPARTMENT OF CONSUMER PROTECTION DEPARTMENT OF CONSUMER PROTECTION HEATING,PIPING Sy G 144,_1 3MITED CONTRACT LIMITED SHELr.31 I" ,'O iTRACT OR MIC1:Rj UIT MIC R 4UIT WINDtOR ��3, +(16096 WINDR' ,E1r6Q96 V � ; LIC./REG NQ, t I �; — EXPIR LIC./RE N - Y' IV , x EXPIR 08 HTG.0303032-S17au� 1�/ 0 «'> 08/31/2009 SHM.0005345-SM �o �� ��'. /31/2009 srU�r f SIGNED _SIGNED Local 860-292-2600 • Connecticut Toll Free 1-888-956-4455 • Fax 860-292-2690 Connecticut License Numbers • P1-203350 • S1-303032 • E1-193730 o,roe Rhvac-Residential$Light Commercial HVAC Loads Elite Software Development,Inc. Aiello Home Services Boiler Replacement Windsor Locks CT 06096 Page 2 Pro ect Report General Pro ect Information Project Title: Boiler Replacement Designed By: David Arildsen Project Date: Friday, October 10, 2008 Client Name: Jim O'Meara Client Address: 151 Berle Road Client City: South Windsor, CT 06074 Company Name: Aiello Home Services Company Representative: David Arildsen Company Address: 600 Old County Circle Company City: Windsor Locks, CT 06096 Company Phone: (860)292-2635 Company Fax: (860)292-2690 Company E-Mail Address: d.adidsen@aiellohomeservices.com Company Website: www.aiellohomeservices.com Company Comment: The right comfort for your home. Deiidif Data W Reference City: Windsor Locks, Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees Elevation: 169 ft. Altitude Factor: 0.994 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor. 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: -5 0 45 70 46 Summer: 95 72 50 72 23 Check Figures Total Building Supply CFM: 2,346 CFM Per Square ft.. 0.714 Square ft. of Room Area: 3,288 Square ft. Per Ton: 651 Volume(ft)of Cond. Space: 27,648 Air Turnover Rate(per hour): 5.1 Buildin Loads -; Total Heating Required With Outside Air: 95,105 Btuh 95.105 MBH Total Sensible Gain: 43,605 Btuh 94 % Total Latent Gain: 2,813 Btuh 6 % Total Cooling Required With Outside Air: 46,418 Btuh 5.05 Tons(Based On 72% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. TMnstallation department\Load Calc-Dave\O'Meara,James.rhv Wednesday, October 29, 2008, 1:45 PM I Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc Aiello Home Services Boiler Replacement Windsor Locks,CT 06096 Page 3 Miscellaneous Report System 1 Main Floor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference; Winter: -5 0 45 70 45.89 Summer: 95 72 50 72 22.91 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00030 0.00030 Pressure Drop: 0.0500 in.wg./100 ft. 0.0500 in.wg./100 ft. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 600 ft./min Minimum Height: 0 in. 6 in. Maximum Height: 18 in. 10 in. tde�Air Data Winter Summer Infiltration: 0.423 AC/hr 0.200 AC/hr Above Grade Volume: X 27,648 Cu.ft. X 27,648 Cu.ft. 11,706 Cu.ft./hr 5,530 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 195 CFM 92 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1— Infiltration &Ventilation Sensible Gain Multiplier: 25.15 = (1.10 X 0.994 X 23.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 15.49 = (0.68 X 0.994 X 22.91 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 82.00 = (1.10 X 0.994 X 75.00 Winter Temp. Difference) Duct Load Factor Scenarios for System 1 Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation Area MDD 1 Supply Main Basement - 0.12 0 442 No 1 Return Main Basement - 0.24 0 164 No T:\Installation department\Load Calc-Dave\O'Meara, James.rhv Wednesday, October 29, 2008, 1:45 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Aiello Home Services Boiler Replacement Windsor Locks,CT 06096 Page 4 Load Preview Report Has Net Rec ft.z Sen Lat Net Sen Sys Sys Sys Duct Scope AED Ton Ton /Ton Area Gain Gain Gain Loss CFM CFM CAM Size NEK- Building 3.87 5.05 651 3,288 43,605 2,813 46,418 95,105 1,243 2,346 2,346 System 1 Yes 3.87 5.05 651 3,288 43,605 2,813 46,418 95,105 1,243 2,346 2,346 18 Duct Latent 586 586 Humidification 6,050 Zone 1 3,288 43,605 2,227 45,832 89,055 1,243 2:346 2,346 18 1-Bedroom 1 1,344 16,033 1,380 17,413 35,032 489 863 863 1-10 2-Living 1,344 13,487 473 13,960 30,442 425 726 726 7-6 3-Family 600 14,085 374 14,459 23,581 329 758 758 7-6 I T:\Installation department\Load Calc-Dave\O'Meara, James.rhv Wednesday, October 29, 2008, 1:45 PM DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# 100��1 BUILDING DEPARTMENT APPROV 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspecto Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Me �Gll `� I L APP ICANT ADDRE S APPLICANT PHONE# O W Ni S F-4 OWNER , l�— O R ADDRESS Q v� • ,r o OWNER PHONE Cam, OHO. 0� C � ESTIMATED COST$ * IS THIS A CONTRACT COST? _ 1'es _No FEE ENCLOSED$ c.�D 100, O�� TYPE OF JOB: �� OR C New Installation , � Alteration/Addition/Repair Reviged4/01// 007 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 0 HEATING 0 RESIDENTIAL 0 A/C 0 COMMERCIAL O VENTILATION ❑INDUSTRIAL HEATING O STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC O WARM AIR 0 UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL 0 OH,-GPM[ OIL TANK LOCATION :0 INSIDEO OUTSIDE CAPACITY ❑GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. Cr- _ C i CONTRACTORS LICENSE NO. YPE STATE SIGNATURE OF APPLICANT ,- DATE NAP Mechanical LLC Customer Name Jim O'Meara Date: 03/14/10 Address 151 Berle St Job Number: City/State South Windsor CT Need AC Unit: 2.5 Ton Home Phone Recommended: 15 Seer Cell Phone Comfort Advisor: Adam Grieve Heating & Cooling Heating Design Temp'Difference 70.0 F 38.9 C Heat Cooling Load Sheet Cooling Design Temp Difference 20.0 F 11.1 C Load Load R-11 R-19 R-30 ; Ceiling (S.F.) 1507 5576 3466 Walls (S.F.) 442 '. Windows (S.F.) Single Double Triple } _........ North 51 :. ,<;:,;,:: 1224 South 64 ``' 2496 East 705180 West 0 Total (S.F.) 185 4 "' 11840 8900 Sliding Doors: Single Double Triple North 0 • Q ::3;..::::..::...:.;...:...:::..,. South 37 f` :::::.:.::.:.... 1776 East 0 :., 0 West 40 3600 .. Total (S.F.) 77 ...... 4389 5376 Wood wl5torm Urethane >' Doors S.F.) 944. 39481 686 Frame 3" 6" Net Wall (S.F.) 163 7691 310 Masona 1" 3" Net Wall (S.F.) 0._ 0 0 Below Gd 0" V, 3" Net Wall (S.F.) 01 - ::.... Basement Floor ;, >......: Slab W/O Perm Insu 0 L . -.0" 1" 2 ::::..:....... Slab W/Perm Insul 0 0 Floor Over Uncond. "0 3„ 6„ Space 0 0 0 Infiltration Length Width Height (LxWxH/60x.5) 132 66 30 8 10164 2904 Mechanical Ventilation 0 01 0 Infil + Mechical Ventilation 132 3142 No. of People 5 2650 Kitchen Allowance 5fandard 1200 Sub Totals: 36716 28634 NOTE: ALL HEAT TRANSFER MULITPLIERS FROM Duct Loss. 5507 4295 ACCA MANUAL"J" SIXTH EDITION FQf :-DIUM USE Total Load: 422231 32929 483 Spring Street Windsor Locks, Ct. 06096 Phone (860) 623-4350 Fax (860) 623-2414 fOR BUILDING PURPOSES ONLY C�A Afz:, v. 71.- ::. ;Z, 73 •�T oj ti C. A I C. N$ �z' �� �� �� ' Not ` Ti.�s p t^�o�. o^ \ N Z-o 2 L F�o. 20 cn C*.:i Y- 0 0 Zo m 0 =,C, '70 L of 6 23, 1971 IFOR BUILDING PURPOSES ONLY 7To\-oj C NA2��5 E, iV�TlaEQ.1N�. V: Pa�:�t�►.�S V-T, o� Q-G 9�O �• . + �p �•SToG.�sti.0� ��tJCwfliU C. `6� 72.2NAf2plll�b, �Es«6 Q V �-L. uj �J 0 I Zo 33 Jrf ( t r .� UN �z' d �n} 11ot �+i�S PoeT\o��oc N 'N.R1v ROu,,y7 To R_��RT S ENE oaD \S CxTfN�..OED. Z /�: loa• Z2 , r It ace, v — �� 2?20• Q ..._ s -ram= v 8= 5► "� -'2 s s • �3 , — l� u. OOfil*, �P�.. rROPERTY OF > 5313 NO. BERLE ROAD SOu---H .aNDSOR, Being Lot No. 20 on map entitled, "Oak Grove Acres - Section No. 1 - O-vmer & Developer Carlo Prestileo - Berle Road Z. Christine Lane - South Windsor, Conn. - By S.A.P - P.A.S. - Scale: 1" = 401 - Dite: Apr. 20, 1971 - Sheet No. 4 of 6 - Revisod 6-11-11 Drainage - Sewer", Griswold & Puss, Inc . , g 7-13-71 San. En rs � A :,� SCALE: 1" _ !�0 Date : D c--• a 1 .. _ GRISWOLD & PUSS INC . caasaa oEnc�r��aiumnc}�- MANCHESTER, C�tiTN. ��^^• ..."� Electric # APPLICATION FOR BUILDING PERMIT Plumbing# HVAC# Date: —do S rinkler# p FINAL APPROVALS Estimated Cost $ Coo Building COMPLETE RED BOXED AREAS Permi F ;''1/ l $ a- Occuj�lV� $ Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit QQ Appr.forCO. SIGN ON REVERSE SIDE t Tor e TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Ad ttion ost) $ The undersigned hereby applies to do work according to the following: CP `s C, Applicant Location of Work Ai,,S Lot No. Applicant' ddress O N11-C, Tel # L Town ZIP: Lic.# Owner Architect Owner's Address NV�; �-_\,c 2D Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit ixw— -C paolU S.p L City Water J Well J Septic System J Sewer J Ins: HO SP Area Basement Garage Approved by Dater �1 Use Group Constru cjt �- , I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located th roper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this ng use is allowed. —� Signed I hereby apply for a Certificate of Kupancy fo work described in this a plication for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS 202000514 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF COMPLETION DATE: 08/04/2020 FEE: GIS ID: 10200165 ZONE: MUNIS APPLICATION# 201901298 THIS IS TO CERTIFY THAT 165 BERLE ROAD UNDER APPLICATION NUMBER 201901298 CONFORMS SUBSTANTIALLY TO THE REQUIREMENTS OF THE CONNECTICUT BASIC BUILDING CODE AND THE ZONING REGULATIONS OF THE TOWN OF SOUTH WINDSOR AND IS HEREBY APPROVED OF OCCUPANCY AS INDICATED BELOW: APPROVED FOR OCCUPANCY REMOVE&REPLACE DAMAGED FOUNDATION SPECIAL CONDITIONS NOTICE: IF THIS CERTIFICATE IS LOST OR DESTROYED,A DUPLICATE SHOULD BE OBTAINED IMMEDIATELY FROM THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: A$lr- OCCUPANCY GROUP: BUILDING OFFICIAL 4/4/2022 9.07 AM ANY CHANGE OR EXTENSION OF THE USE HEREIN APPROVED REQUIRES ANEW CERTIFICATE OF OCCUPANCY INSPECTION FIELD SHEET 04/04/22 Printed by Middleton, Morgan 09 07 01 INSPECTION: 129307 FINAL PERMIT: STATUS APPLICATION: 201901298 LOC: 165 BERLE ROAD SOUTH WINDSOR PROPERTY ID: 10200165 OWNER: COONEY JOSEPH M CONTRACTOR: DON CHILDREE GENERAL REQUEST BY: PROD DESC: REMOVE & REPLACE DAMAGED FOUNDATION WORK ORDER: INSPECTOR: WEAR RESULT: PASS REQUESTED: 06/04/20 PRIORITY: SCHEDULED: 06/04/20 COMPLETED: 06/04/20 UNPAID FEES: 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 11/15/19 ROSE PASS B001 FOOTING REBAR 11/07/19 DOUG PASS B001 FOOTING 06/01/20 WEAR FAIL B010 FINAL * Smoke & CO detection required to be operational 1000091 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 03/23/10 GIS ID: 10200151 FEE: 90.00 MUNIS APPLICATION# 201000250 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: H.A.R.P.MECHANICAL,LLC ADDRESS: 151 BERLE ROAD ADDRESS: 483 SPRING STREET OWNER: OMEARA JAMES P&GEORGIA A WINDSOR LOCKS,CT 06696 151 BERLE ROAD SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: HEATING AND COOLING UNIT SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 3/23/2010 l 1:30 AM THE FEE ABOVE INCLUDES A$0.22 PER THOUSAND CT STATE EDUCATION SURCHARGE