HomeMy WebLinkAbout150 FRAZER FIR RD Electric # 150 F r a z e rAV�ACATION FOR BUILDING PERMIT
Plumbing#
HVAC# 12000354 Date:
Sprinkler# 3 oar-w
FINAL APPROVALS Estimated Cost $
Building COMPLETE RED BOXED AREAS Permit Fee $_ 3
Engineering TYPE OR PRINT ONLY Occupancy Fee $�c�-a Affidavit Eng. Insp. Fee $
Appr.forCO. - ► SIGN ON REVERSE SIDE
Total Fee $��4��
TO THE B ILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant ` ii rl u` 4WionofWork R Lot No.
Applicant's Address 400 CAn%e- k 'V-4-A• UATt 3—r Tel # 0- of —70.fs—
Town S. . If / Zip O 607 4 Lic.# l 0
Owner a.rA."E Ar 4AZIK ArchitectT NIA♦ 4P1 -.xl-r
Owner's Address Architect's Address _��O- ri, I t o%
Zip ,L-c-,- 4-4c,h 04 . Zip 4I►
Sq. Ft. New Area: 1 st Fl. `6 70 2nd F 7,3 O 3rd FI. le Total New Area 3 4
Purpose of this permit _ Q��t/ ✓�9-Q
City Water Well J Septic System J Sewe;.7—
Ins: HO S ' Area Basement Garage
Approved byq7S Date .-�> 11 Use Group Construction Type
Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of P
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in wh h this buildto ing and i u/ers Ve�,
Signed �
M
I hereby apply for a Certificate of Occupan for the work described in thi application for the permit.
I� N
Signed
DO NOT WRITE BEA THIS LINE
INSPECTION COMMENTS
1'
INSPECTION FIELD SHEET 11/06/12
Printed by Peart, Dayshell 14 14 56
INSPECTION: 49145 FOOTING PERMIT:
STATUS:
APPLICATION: 201200697
LOCATION: 150 FRAZER FIR ROAD
SOUTH WINDSOR
PROPERTY ID: 34430150
OWNER: MANNARINO BUILDERS LLC
CONTRACTOR:
REQUEST BY:
DESCRIPTION: NEW HOME 3,400 SQ. FT.
WORK ORDER:
INSPECTOR: DOUG RESULT: PASS
REQUESTED: 06/06/12 PRIORITY:
SCHEDULED: 06/06/12 AM COMPLETED: 06/06/12
UNPAID FEES 00 Date Time
TIME TRAVEL ONSITE
COMMENTS
ALL INSPECTIONS:
INSPECTED INSPECTOR RESULT INSP DESCRIPTION
06/15/12 ROSE PASS B002 FOUNDATION
08/28/12 ROSE PENDING B003 FRAMING (ROUGH)
08/30/12 DOUG PASS B003 FRAMING (ROUGH)
09/06/12 DOUG PASS B004 INSULATION
11/06/12 ROSE N/A B005 FIREPLACE / CHIMNEY
11/02/12 DOUG PASS BO10 FINAL
08/03/12 ROSE PASS E001 ELECTRIC SERVICE
06/18/12 DOUG PASS E002 ELECTRIC UNDERGROUND
08/28/12 ROSE PASS E003 ELECTRIC ROUGH
08/28/12 ROSE PASS H003 HVAC ROUGH
07/31/12 ROSE PASS P002 PLUMBING UNDERGROUND
11/06/12 DOUG N/A P003 PLUMBING ROUGH
10/10/12 ROSE PASS P004 PLUMBING GAS TEST
11/02/12 FOLG PASS Z003 CO PLANNING INSPECTION
f
I'
. SITE COMPLIANCE CHECKLIST
TOWN OF SOUTH WINDSOR,CONNECTICUT
***** FOR C OF 0*****
ADDRESS ISO � ,
rya ze: �► (� LOT/UNIT# ��
Reviewed by BD (Engineering)
CONTACT/DEV rV16V1 Vlo1f j V7 O
Date Reviewed I► i Denied GJ
PHA
Reviewed byt$- (Planning)
Date Submitted /1-�,?-/01, pate Revi►wved p m—ec#Denied
Date Reviewed Approved/Denied(Health)
As required in the Zoning and/or Subdivision Regulations,no Certificate,of Occupancy stiaa be issued urib1 grading
Plans have been Complied with and approved by the Town Engineer. The minimum requirements sttall include:
Approved Denied N/A
�f
1. Approved building permit plan
2. Finish grading per approved
budding pmA plan
// 3. Site work;i.e.trees,shrubs,
---cam dump sters,required paddn9
4. Utility bcabon;
—�� a. sanitary sewer/septic systems
—1C b. foundation drain L
—� C. electrical&telephone
Ntl
- - � d. water � N g
5. Sewer oorurction charge paid
!/ 6. Appropriate certification
7. Bonding
B. Planning&Zoning/
Inland Wetlands Considerations
a. Lighting
b. Signage
Freestanding Wall
C. Fee in lieu of Open Space
COMMENTS:__
-._ S/aV Wmolloy/site Oanpliance dheddist
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: � BUILDING �-
DEPARTMENT
APPROr 1540 SULLIVAN AVENUE
644-2511 ext. 230 Bldg.Permit#
D to Building Ins
Application must be printed or typed
FEE SCHEDULE Location of Job:
1,5 O c a 2cc �—, . <- R
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS
APPLICANT PHONE# 0. - a
�0W N S4. OWNER 1`I�Gr�, �,c � r �a �����2c_c
OWNER ADDRESS
OOWNER PHONE U
C = ESTIMATED COST$
a
IS THIS A CONTRACT COST? v Yes _No
o �� FEE ENCLOSED$�2
TYPE OF JOB: �q
SOR•CO VNew Installation
Alteration/Addition/Repair ���
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WrH A
RESIDENTIAL
BUILDING PERMIT APPLICATION? El YES
J� NO
/ '
BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE❑EDUCATIONAL FUTURE USE AND OCCUPANCY
❑ INSTITUTIONAL
❑ FACTORY ENGINEER'S NAME PHONE
❑ STORAGE
❑GARAGE ADDRESS
❑MIXED USE
(Other please specify) CITY STATE ZIP
TYPE OF INSTALLATION 2 / 'Z Lr,�Z�)j SIZE OF MAIN DRAIN �A ,
NO. OF TOILETS_ STYLE NO. URINALS STYLE
NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES .3
NO.OF CONDUCTORS ` SIZE_ NO.OF STACKS�_ SIZE _
AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS
NO.OF OTHER FIXTURES KIND
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW RYES ❑NO
SIZE OF WINDOWS IF NONE C.F.M.OF VENTILATOR
SIZE OF DUCTS (EV�OR SEPTIC TANK
SIZE OF WATER MAIN 1 SIZE OF WATER PIPING&RISER
WATER HEATER: TYPE Cu S MANUFACTURER
DESCRIPTION OF WORK
\ l\ % �
THE UNDERSIGNED HER BY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
APPLICATION FOR ELECTRICAL PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT /a—Z 4y;�
APPR vE 1540 SULLIVAN AVENUE
,,,
644-2511 ext. 230 Bldg.Permit#
12606
Date Building Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 /c5"D �.>01��cn- 2z7 lloeo �2
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT ' /f �� �i'r/Z lr X/G
APPLICANT ADDRESS
C- 7—
APPLICANT'S PHONE# �6a - �L��—` -t
OWNER �22/?`�/,I � i�v4 r Arc_
OWN OWNER
OWNER ADDRESS 46Q CZ-Z zeel � &itl/T
C T
OWNER PHONE -a
O * `" ESTIMATED COST$
V IS THIS A CONTRACT COST? VYes No
FEE ENCLOSED $ Z.2- 0
TYPE OF JOB:
Q CQ� __t,/New Installation C x s /
Alteration/Addition/Repair
�, 2ot 20o c�q�
Revised 03/05/10
APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATE WITH A
BUILDING PERMIT APPLICATION? MYES ❑ NO
9 RESIDENTIAL CURRENT USE AND OCCUPANCY
❑ BUSINESS
❑ ASSEMBLY FUTURE USE AND OCCUPANCYA4/ GcJ
❑ EDUCATIONAL
❑ INSTITUTIONAL ENGINEER'S NAME PHONE
❑ FACTORY
❑ STORAGE ADDRESS
❑ GARAGE
❑ MIXED USE CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD 4/^4
SIZE OF SERVICE SIZE OF MAIN CONDUCTORS D
NUMBERS OF METERS l NUMBERS OF DISCONNECTS AND RATINGS
NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES n/NO
NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES �/d NUMBER OF OUTLETS S5 d
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
Gt///Z I.cJG ic/��✓ e�i.�G-a��G-'i��-r lG f/ /rind.,n. �`''
THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR-
MANCE OF SUCH WORK
CONTRACTORS LICENSE NO. TYPE
STATE
SIGNATURE OF APPLICANT % DATE �� ��
Kevis,ed a•ui 2002
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby:
BUILDING DEPARTMENT — -
APPROVED 1540 SULLIVAN AVENUE
Bldg. Permit#
644-2511 ext. 230 l.20iS 6$574
Date Building Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job: 21
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT ADVANCED Heating & Air Conditioning, Inc.
APPLICANT ADDRESS 701 Nutmeg Rd. No.
South Windsor, CT 06074
APPLICANTPHONE# (860 ) 282-0205 _
OWNER i -7/f 62 �/12 D /1�t,45
�(�W N S F �Q'
-4 c.�
OWNER ADDRESS !e C' (r _
O .o OWNER PHONE �� � �n_ 6
C ESTIMATED COST$ �� , � Gcp COD
_
* IS THIS A CONTRACT COST? -yes _No
•b " off, FEE ENCLOSED _
TYPL OF J013:
dS R_CpN
V I
— iliicraUun �\�l�litiuirll��lian
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
PletMATING SIDENTIAL
ef-,k/c ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
ElHYDRONIC SWARM AIR Cl UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE �'c,—°F INSIDE DIFFERENCE�F
TOTAL HEAT LOSS (BTUH)7h F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT—BTUH) 0 NET RATING(OUTPUT—BTUH) 767
TYPE OF FUEL
❑ OIL—GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY
&GAS—INPUT f— LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE J�-F INSIDE ZO °F DIFFERENCE Z 57 °F
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(LNCLUDING MAKE&MODEL NO.)
49
TONNAGE COOLING CAPACITY(BTUH) 6 �!
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
303614 S-1 _ CT _
CONTRACTORS LICENSE NO. TY STA/
SIGNATURE OF APPLICANT DATE
I
I
Lot #42, 150 Frazer Fir Rd.
HVAC Load Calculations
for
Mannarino Builders
i
RHVACRESIDENTIAL
HVAC LOADS
Prepared By:
Stephen Smith
Advanced Htg&AC Inc
Monday, August 06, 2012
v..�-z. n_. .-�,. ,_ _.__�., _ ,.
--- ------ ---------------------- ---- ------ -------- --------
Rhvac-Residential Light Consnsrclam HVAC Loads Elite Sottware Development,Inc.
Advanced Htg 8 A/C Lot#42, 150 Frazer Fir Rd.
South Windsor,CT 06074 Page 36
System 1 Room Load Summary
Htg Htg Run Run Clg Cig Cig Zone Cig Air
Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM
---Zone 1--
1 Dining 225 7,804 101 1-7 476 2,795 355 127 1.00 127 127
2 Kitchen 270 2,591 34 1-6 481 2,078 68 95 1.00 95 95
3 Den 195 6,521 85 1-6 540 2,333 313 106 1.35 143 106
4 Foyer/stairwell 272 5,602 73 1-5 593 1,779 279 81 1.19 96 81
5 Laundry 84 2,425 32 1-4 392 752 85 34 1.00 34 34
6 Living 510 7,738 101 1-6 520 2,243 338 102 1.00 102 102
7 Family 312 8,830 115 1-7 537 3,158 355 144 1.25 180 144
Zone 1 subtotal 1,868 41,511 539 15,138 1,793 689 777 689
---Zone 2---
8 Bed 3 285 4,270 55 1-5 592 1,776 118 81 1.00 81 81
9 Bed 4 240 3,551 46 1-5 538 1,612 118 73 1.25 92 73
10 Lav 120 1,046 14 1-4 263 504 30 23 1.00 23 23
11 Upper 289 4,500 58 1-6 524 2,260 216 103 1.35 139 103
Foyer/stairwell
12 Bed 2 306 3,916 51 1-5 546 1,636 169 74 1.00 74 74
13 Master Bedroom 408 6,814 89 1-7 471 2,765 178 126 1.00 126 126
14 Master Lav 238 3,563 46 1-5 495 1,485 89 68 1.00 68 68
15 Master Closets 168 2,691 35 1-4 555 1,064 0 48 1.00 48 48
Zone 2 subtotal 2,054 30,351 394 13,102 918 596 650 596
System 1 total 3,922 71,862 934 28,240 2,711 1,285 1,427 1,285
System 1 Main Trunk Size: 16xl7 in.
Velocity: 727 ft./min
Loss per 100 ft.: 0.057 in.wg
Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 2.58 91%/9% 28,240 2,711 30,951
Recommended: 3.14 75%/25% 28,240 9,413 37,653
Equipment Data
Heating System Cooling System
Type:
Model:
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
C:\Documents and Settings\Steve Smith\Desktop\My Dropbox\Projects\Mann Lot 20 DzenWarmi*\August 06, 2012, 3:37 PM
SITE COMPLIANCE CHECKLIST
TOWN OF SOUTH WINDSOR,CONNECTICUT
***** BUILDING PERMIT*****
ADDRES /UNIT# 42— Reviewed by �� (Engineering)
CONTACT/D— Ilk Date Reviewed Approved/ Hied
PH# ��t 2 IS —�]O�5 Reviewed by (Planning)
G
Date Submitted Date Reviewe Szl rov /Denied
Reviewed by (Health Dept)
Date Reviewed Approved/Denied
In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic
Plot Plan shall be submitted for approval. The minimum requirements shall include:
Approved Denied N/A
✓ 1. Name,address&phone number of
owner/applicant
2. Name,address&phone number of plan
/ preparer
3. Zoning Information—i.e.zone,open space,
floodway,street address
4. Plot Plan at 1"=40'scale
a. Subdivision reference,abutting properties,etc.
b. Easements of record
C. Lot description,bearings,building lines,
distances,area,etc.
d. Contours,existing&proposed, 1 Or 2ft.interval
where appropriate
e. Building location with dimensions. Elevations of
proposed finish floor,garage floor¢erline
of road at driveway
f. Elevations of gravity drainage systems,sanitary
&foundation drain at the house and the street
g. Tentative utility location(gas,water,electric,
septic system,etc.
h. Title block with name&address of preparer,
date,appropriate certification,live seal&live
signature consistent with the Board of
Registration requirements. (P.E.&L.S.)
S. Sedimentation and erosion control
6. Special Planning&Zoning,Inland/Wetiands
considerations(Plans on file w/Town Clerk)
COMMENTS:
s/engineering/molloy/building compliance checklist
NO TES -
1. AREA OF LOT 42 = 23220 SQ.FT. = 0.533 ACRES
2. ZONE OF SUBJECT PARCEL /S RR OPEN SPACE".
OPEN SPACE 'D1" CONSTRUCTION ENTRANCE PAD- M'F ON'= 40 FEQET'REMENTS:
TO BE DEEDED TO THE TOWN OF SOUTH WINDSOR NOT TO SCALE 61DE = 10 FEET
FRAZER FIR ROAD REAR = 20 FEET
0 000 0oo00 00 00c J. BOUNDARY INFORMATION TAKEN FROM PLANS EN777LED -
`2s� 'S0�O10 0 ' 0 c 'DZEN TREE FARM SUBDIVISION PLAN PREPARED FOR MANNARINO BUILDERS, INC. MASKEL ROAD AND
o obo°o0 0 oo� 2 BARBER HILL ROAD SOUTH W/NDSOR, CONNEC77CUT SCALE" 1 IN.= 40 FT. DA 7E• AUGUST 29, 2007
°gyp REVISION DATES TO 6-17-08 SHEETS Sl, S2, S3, S4 AND S5 ALFORD ASSOCIATES, INC. CIVIL
�080o�o�`bo� o ENGINEERS WINDSOR, CONNECTICUT'
0 0 0�0 0 ^
�,,....RRo II 4. APPLICANT MAP PREPARED BY-
MANNARINO 03'40"W vf_° � o O BUILDERS, INC. ALFORD ASSOCIATES, INC.
108.00' ,' o`b °o®» C/oROBERT MANNARINO 200 PIGEON HILL ROAD
400 CHAPEL ROAD, SU17E 3-F P.O. BOX 484
i 0. 0°000 0 0 SOUTH WINDSOR, CONNEC77CUT 06074 WINDSOR CONNEC77CUT 06095
° � 7EL. # (860) 289-7055 TEL. # (860) 688-7288
N 20' R.Y. O °� 0 000 000�o o _
3 PLAN
o ^ 'cNo I 4" MINIMUM CONN. 5. ELEVA77ONS ARE BASED ON NGVD29.
DOT 2" STONE
�N p N 2 ' �, -/ ' SL FILTER FABRIC 6. NO ZONING WOLA77ONS W17H RESPECT TO LOCA77ON OF HOUSE, IF ERECTED AS SHOWN.
o 42 ^ fW!DTH= 10' MIN. Z CONTRACTOR SHALL VERIFY LOCA77ON AND ELEVA77ON OF EXIS77NG U77LI77ES PRIOR TO ESTABLISHING FINAL
ET�PN� GRADE OF PROPOSED F0077NGS AND FOUNDATION. CONTRACTOR SHALL INSTALL TEMPORARY EROSION CONTROL
-'- W - SECTION MEASURES FOR STOCKPILED MATERIAL AND AT TOPS OF SLOPES DURING FOUNDA77ON EXCAVATION. M/RAF7 FABRIC
_ _ 250 -- NOTES SILT FENCE AND/OR TEMPORARY VEGETATION IF PILES ARE TO REMAIN /N PLACE FOR EX7ENDE0 PERIODS OF E.
1. THE PURPOSE OF A STABILIZED CONSTRUCTION ENTRANCE IS TO REDUCE
THE TRACKING OR FLOWAGE OR SEDIMENT ONTO EXISTING PAVEMENT. 8. DURING CONS7RUC77ON, M/RAFI FABRIC CHECK DAMS ALONG SWALES MAY BE REQUIRED BY TOWN STAFF
- _ 2. BEFORE CONSTRUCTION ENTRANCE INSTALLATION, THE AREA OF THE
./ ENTRANC_ SHOULD BE CLEARED OF ALL VEGETATION, ROOTS AND OTHER 9. LEGEND -
' 4, UNDESIRlBLE MATERIAL
EXISTING CONTOUR
3. THE ENTRANCE SHOULD BE MAINTAINED IN A CONDITION WHICH WILL
PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO EXISTING PAVEMENT. X 310.0 EXIS77NG SPOT GRADE
THIS WILL REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE OR
AD61110N.4L LENGTH AS CONDITIONS REQUIRE.
31 p PROPOSED CONTOUR
A
258.5 ,DECK PROPOSED SPOT GRADE
256.0' 256 310.0
'-- 17.5' GRADE TO DRAIN
N, SURFACE WATER /S TO BE DIRE07ED AWAY FROM 7HE HOUSE AND GARAGE
PROPOSED 10' PROPOSED HOUSE PROPOSED HOUSE
HOUSE I 12' FD FL=2521 o W PROPOSED WATER SERVICE
SAN FL= 249.0 '
� Fp PROPOSED 670 FOOTING DRAIN LINE
30' 54.5' `
N cv CHECK VALVE IS REQUIRED ON F0077NG DRAIN LINE AT HOUSE
36.0' Oo_ 260.0 { `° G PROPOSED GAS SERVICE TO CONNECT TO EXIST. IN STREET
PROPOSED BITUMINOUS CONCRETE DRIVEWAY r O
MAINTAIN A MINIMUM OF 3 FEET BETWEEN 259.0 I 40• I�< 1 T PROPOSED TELEPHONE SERVICE TO CONNECT TO EXIST. IN STREET
THE PROPERTY
V N AND THE N PROPOSED ELECTRIC SERVICE TO CONNECT TO EXIST. IN STREET
PROPERTY LINE 262 N I 12'` o I Cn E
Q1 Y cv _-I pa
26-0 5% 1---'c,)------ ___ s� - MIRAFI FABRIC FENCE - TO BE PLACED PRIOR TO ANY CONSTRUCTION AND
SHALL REMAIN IN PLACE UN77L DISTURBED AREA 1S STABILIZED
- - - - - - - - - 20' WIDE STREET TREE EASEVENT
�- ---T---- _ IN FAVOR OF 774E TOWN OF SOUTH WINDSOR
10. PROPOSED HOUSE -
257.0 256.8 I 255.8 10' WIDE C.L.& P. CO. EASEMENT
PROPOSED GARAGE FLOOR = 260.0
4' WIDE CONCRETE i'rALK PROPOSED TOP OF FOUIJDA770N = 261.0
PROPOSED FINISHED FLOOR 262.0
_-8"%c WATER MAIN ------- 255.9 --CB f(31- L-- APPROXIMATE BASEMENT FLOOR = 2533 (WALKOUT)
8'0 SANITARY SEW ZF=255.65 V)
ER TOP CF FOUNDA77ON TO BE A MINIMUM OF EIGHT (8) INCHES ABOVE THE FINAL EXTERIOR GRADE.
TFN 256!414 �256 FRAZER FIR ROAD USE GARAGE FLOOR ELEVA77ON TO SET GRADE OF 774E HOUSE. ADJUST OTHER FLOOR ELEVA77ONS
-- __ _ BASED ON THE ARCH17ECTURAL PLANS.
CB //32 (DOUBLE)
TF=255.65 11. PRIOR TO STAR77NG CONSTRUCTION, 774E CONTRACTOR SHALL BE RESPONSIBLE TO MAKE SURE THAT ALL
REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED. NO CONSMUC77ON OR FABRICA77ON SHALL
2s6.- BEG/N UN77L THE CONTRACTOR HAS RECEIVED AND THOROUGHLY REVIEWED ALL PLANS AND 07HER
_ _ '-'r-' DOCUMENTS BY ALL OF THE PERM/TTING AU7HORll7ES
S60 03'40"IE
108.00' END OF EXISTING SEEDING SCHEDULE -
INSTALL CONSTRUCTION ENTRANCE PAD SANITARY SEWER LATERAL
PRIOR TO ANY CONSTRUCTION FL= 246.95 ALL DISTURBED AREAS NOT PAVED OR LANDSCAPED SHALL BE LOAMED WITH
(A MINIMUM OF 20 FEET LONG) PROPOSED SAN/AIRY SEWER LATERAL 4" MINIMUM OF TOPSOIL SEED AS INDICATED BELOW. CONDITION SOIL
FROM THE END OF THE EXIST. LATERAL WITH FERTILIZER AND LIMESTONE AS INDICATED BY SOIL TEST.
TO 774E HOUSE
PROPOSED F0077NG DRAIN PERMANENT VEGETATIVE COVER:
TO 77E INTO CB #31 58'- 6">� ® 3.59 SEEDING DATES: APRIL 1 TO JUNE 15 & SEPTEMBER 1 TO OCTOBER 15
FD FL= 251.2 (MIN/MUM SLOPE= 2.07.) A OR AT OTHER TIMES, WEATHER PERMITTING
LAWN AREAS:
USE THE FOLLOWING MIXTURE OR EQUAL AS APPROVED BY DESIGN ENGINEER:
KENTUCKY BLUEGRASS 45%
CREEPING RED FESCUE 45%
PERENNIAL RYEGRASS 10%
APPLY 1-3 LBS./1000 S.F.
TEMPORARY VEGETATIVE COVER:
SEEDING DATES: MARCH 1 TO JUNE 15 & AUGUST 1 TO OCTOBER 15
OR AT OTHER TIMES, WEATHER PERMITTING
USE THE FOLLOWING SEED OR EQUAL AS APPROVED BY DESIGN
THIS SURVEY AND MAP HAS BEEN PREPARED /N ACCORDANCE WITH SEC77ONS ENGINEER -
ANNUAL RYEGRASS 100%
20-300b-1 THROUGH 2O-300b-20 OF THE REGULATIONS OF CONNEC77CUT APPLY 1 LB./1000 S.F.
STATE AGENCIES- "MINIMUM S7ANDARDS FOR SURVEYS AND MAPS /N T14E
STATE OF CONNECTICUT" AS ENDORSED BY THE CONNEC77CUT ASSOCIA77ON
OF LAND SURVEYORS, INC.. IT IS A LIMITED PROPERTY/BOUNDARY SURVEY
BASED ON A DEPENDENT RESUIZVEY CONFORMING TO HORIZONTAL ACCURACY
CLASS A-2 AND INTENDED TO B.- USED FOR AN IMPROVEMENT LOCA77ON SURVEY.
GRAPHIC SCALE o��iu��iiv��,. �t�rin" TO THE BEST OF MY KNOWLEDGE AND BELIEF THIS
40 0 40 80 06 F COM01" ' A9'��OF CON...0 A.a PREPARED FOR MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON.
e �A. ALE''_0 :. O P M. Lp0: O
- t, �AP�`_;' °�� G� ,.�''�;�.°� � MANNARINO BUILDERS INC.
..� ,_
L.S. N0. 9344
( IN FEET )
*� IMPROVEMENT LOCATION SURVEY ,f
THE LOCATIONS OF UNDERGROUND UTILITIES ARE e ', No. 9344 No,_9 .°
Cl I/lL ENGINEERS
o
'.A�o':�/CENSE�• 0��®e < -�!CENSE��'oq-0°ss ,' WINDSOR, CONNECTICUT
APPROXIMATE AND ALL UTILITIES MAY NOT BE T - . o q .. y 0 DZEN TREE FARM
��oiFSS/ONAL �NG''�� •�po*' D S U R N E$orO O
SHOWN. PRIOR TO CONSTRUCTION, CONTRACTOR �•.,,,,����ri�r►� •e.,,,,,�,,,uio' � WILSON M.ALFORD,JR.,P.E.&L.S.
SHALL CALL 1-800-922-4455 AND HAVE THE LOT 42 -
UTILITIES MARKED ON THE GROUND. DATE REVISION NOT VALID WITHOUT A LIVE SIGNATURE AND EMBOSSED SEAL 150 FRAZER FIR ROAD SOUTH WINDSOR, CONNECTICUT SCALE: 1 IN. = 40 FT. DATE: MAY 31, 2012
D:M08060PP-42 P:MO6024 FOLDER:MANNARINO FILE:MANNARINO-DZEN
Sown vvinasor
BUILDING DEPARTMENT
fO THE BUILDING DEPT. TOWN OF SOUTH WINDSOF
This certified that this plan and specifications are true
copies bf the proposod building or alterations to be
erected at n `
street
together with amendments stated in appli•atlon ano
filed with plan and I agree to comply with all zoning.
Building and state laws and such orders as shall be
issued by the Building Department during pendency
of this application and final.issuance of a building
permit.
W .w
Signed � �r//,f'
This plan Is`approved subject mo, the condition that
orders and ordinances regulating building shall bs
eomp,wd with.
Conditionally Approved These flied wltN
,Building Inspector Clerp
net• No.
�®�O�\�1�' ��``
r
NO TES -
1. AREA OF LOT 42 = 23,220 SQ.FT. = 0.533 ACRES.
2. ZONE OF SUBJECT PARCEL IS 'RR OPEN SPACE".
OPEN SPACE 'D1"
MIN/MUM YARD REQUIREMENTS.
TO BE DEEDED TO THE TOWN OF SOUTH WINDSOR FRONT= 40 FEET
SIDE = 10 FEET
REAR = 20 FEET
J. BOUNDARY INFORMATION TAKEN FROM PLANS ENTITLED -
DZEN TREE FARM SUBDIVISION PLAN PREPARED FOR MANNAR/NO BUILDERS, INC. MASKEL ROAD AND
BARBER HILL ROAD SOUTH WINDSOR, CONNECTICUT SCALE" 1 IN.= 40 FT. DATE.• AUGUST 29, 2007
REVISION DATES TO 6-17-08 SHEETS Sl, S2, S3, S4 AND S5 ALFORD ASSOCIATES, INC. CINL
v, ENGINEERS WINDSOR, CONNECTICUT"
s�
252.5+ + 251.4 + 250.8 + 250.2 4. APPLICANT• MAP PREPARED BY.•
+ 253.5 N6003'40"W MANNARINO BUILDERS, INC. ALFORD ASSOCIATES, INC.
108.00' % ROBERT MANNAR/NO 200 PIGEON HILL ROAD
400 CHAPEL ROAD, SUITE 3-F P.O. BOX 484
SOUTH WINDSOR, CONNECRCUT 06074 W7NDSOR, CONNEC77CUT 06095
Lu 20' R.Y. TEL. # (860) 289-7055 TEL. # (860) 688-7288
_ o o
o p T "cNo I 5. ELEVATIONS ARE BASED ON NGVD29.
CN 1i i i�' N 6. NO ZONING WOLA77ONS WITH RESPECT TO LOCATION OF EXISTING FOUNDATION, AS SHOWN.
rn N 250.7+� Z + 249.5
5 Z EX/STING HOUSE -
;+ 251.9 �� wETLPNp �"� GARAGE FLOOR ELEVA770N= 259.83
250 FIN/SHED FLOOR ELEVATION= 261.81
+ 254.9 +I 252.7 BASEMENT FLOOR ELEVATION (WALKOUT)= 253.25
253.5
8. LEGEND
43 ? + 253.2 + 250.5 4' EXISTING CONTOUR
62 I x 310.0 EXISTING SPOT GRADE
256.2`+'
251.6
"!5P,,257.1 a' I +252.2 + ''�' + 252.7 W WATER SERVICE
9' 16' FD- FOOTING DRAIN LINE
2'x6.2' DECK 256.4
25g,4 CHII.INEY` * 2531 -'� --- - G GAS SERVICE
�. 25 6.8 `255.3 255.0
`t 19 1' N 23.5' N 12 a' /257'52 S 610 SANITARY SEWER LATERAL
258.13 TELEPHONE, ELECTRIC AND CABLE TV SERVICES
258.39 17.0 EXISTING HOUSE T,E,7V
257.9 EXISTING HOUSE - _
EXISTING HOUSE EM FD FL=2520 0 - -
35.9 Ln
SAN FL= 249.Ot AC 258.11 TRANS ❑ TRANSFORMER ON CONCRETE PAD
fi258.7059 69 COVERED STOOP 7.6;N 12 a' GM 257.4 ❑AG AIR CONDITIONING UNIT ON CONCRETE PAD
260.5 258.2 H 259.70 12.1' n 258.8 i 258.50 • GM GAS METER
u 258.88 \ 23.0' 1 GV
+ 260.7 1 40'1" I
o I Z" 257.8 ,� GAS GATE
259.0257 8 OD r � n -' -- - EM ELECTRIC METER
_ u) r BRICK 259.07 25 .94 v1
BIT. CONCRETE DRIVEY AY - N N ,?AVER WALK--- '" 256.8 N WV
g�v a.a0 + p -J~+ + 20' WIDE STREET TREE EASEMENT x WATER GATE
5 TEL F 2g7,3 V __256.2 IN FAVOR OF THE TOWN OF SOUTH WINDSOR
2 TRANS 257.7
y�T _ _ _ '' _ _ TEL O TELEPHONE HAND HOLE
257.10 TV 256.62 42.0' I ti� 255.3 10' WIDE C.L.& P. CO. EASEMENT
T�] TELEPHONE BOX
255.88' 4 255.23 4' WIDE CONCRETE WALK OF ELECTRIC MAN HOLE
8"7 WATER MAIN 256.24
c 255.80 235_80 _ cB31_ 255_ 2 _254.79 254.54 _254.37 _254.17 _______ Tv ❑ CABLE 7V BOX
------------------
8"4 SANITARY SEWER -F\255.60_ (I
i
TFN'25& 1256 FRAZER FIR ROAD
1 �
-- -
0')---EB CB y32 (DOUBLE)
TF=255.65 `-
`
S60 03'40'E
108.00, END OF EXISTING
SANITARY SEWER LATERAL
FL= 246.95
SANITARY SEWER LATERAL
FROM THE END OF THE EXIST. LATERAL
610 FOOTING DRAIN TO 774E HOUSE
77ES /N TO CB #31 58'- 610 0 3.59'f
FD FL= 250.85
THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SEC77ONS
20-300b-1 THROUGH 2O-300b-20 OF 774E REGULA77ONS OF CONNEC77CUT
STATE AGENCIES- "MINIMUM STANDARDS FOR SURVEYS AND MAPS IN 7HE
STATE OF CONNEC77CUT" AS ENDORSED BY THE CONNEC77CUT ASSOCIA77ON
OF LAND SURVEYORS, INC.. IT IS A LIMI7ED PROPERTY/BOUNDARY SURVEY
BASED ON A DEPENDENT RESURVEY CONFORMING TO HORIZONTAL ACCURACY
CLASS A-2 AND INTENDED TO BE USED FOR AN IMPROVEMENT LOCA77ON SURVEY.
GRAPHIC SCALE ttt�t� TO THE BEST OF MY KNOWLEDGE AND BELIEF THIS
®�
40 0 40 80 ,eo 1F CON/yECTp•A eeee�05 CONNECT/•.• PREPARED FOR MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON.
ALP
'' O
% I
( IN FEET ) �� *h * �'A *
L.S. NO. 9344
THE LOCATIONS OF UNDERGROUND UTILITIES ARE No. 9344 e�� = 0. 9344 oeoe� IMPROVEMENT LOCATION SURVEY CIVIL ENGINEERS
••��oF:�/CENSE�•°\��'eeoo '•.•�q:4!CENSE�•yo'eeoe RFT.
INDSOR, CONNECTICUT
APPROXIMATE AND ALL UTILITIES MAY NOT BE DZEN TREE FARM
•���SS�ONAL E��O'e •�Wi�rO•S U RN�tt��e •
SHOWN. PRIOR TO CONSTRUCTION, CONTRACTOR 11-1-12 ADDED AS-BUILT HOUSE, IMPROVEMENTS, UTILITIES & GRADES ��e� '"���•��ej°� LOT 42 - • ILSON M.ALFORD,JR.,P.E.&L.S.
SHALL CALL 1-800-922-4455 AND HAVE THE
UTILITIES MARKED ON THE GROUND. DATE REVISION NOT VALID WITHOUT A LIVE SIGNATURE AND EMBOSSED SEAL 150 FRAZER FIR ROAD SOUTH WINDSOR, CONNECTICUT SCALE: 1 IN. = ATE: MAY 31, 2012
D:M0806OPP-42 P:M06024 FOLDER:MANNARINO FILE:MANNARINO-DZEN
V,ecex
019
NOV p 21p1Z
ENG
201200190 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER CERTIFICATE OF OCCUPANCY
DATE: 11/06/12
GIS ID: 34430150 FEE: 10.00
MUNIS APPLICATION# 201200697 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: MANNARINO BUILDERS INC ADDRESS: 150 FRAZER FIR ROAD
ADDRESS: 400 CHAPEL ROAD OWNER: MANNARINO BUILDERS LLC
UNIT 3F 400 CHAPEL ROAD#3F
SOUTH WINDSOR,CT 06074 SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: NEW HOME 3,400 SQ.FT.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITHY THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: AL
11/6/2012 2:15 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
12000354 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 06/25/12
GIS ID:34430150 FEE: 3,231.00
MUNIS APPLICATION# 201200697 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: MANNARINO BUILDERS INC ADDRESS: 150 FRAZER FIR ROAD
ADDRESS: 400 CHAPEL ROAD V OWNER: MANNARINO BUILDERS LLC
UNIT 3F 400 CHAPEL ROAD#3F
SOUTH WINDSOR,CT 06074 SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: NEW HOME 3,400 SQ.FT.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
6/25/2012 8:43 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1200305 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 08/15/12
GIS ID: 34430150 FEE: 225.00
MUNIS APPLICATION# 201200697 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ADVANCED HEATING&A/C ADDRESS: 150 FRAZER FIR ROAD
ADDRESS: 701 NUTMEG ROAD NORTH OWNER: MANNARINO BUILDERS LLC
SOUTH WINDSOR,CT 06074 400 CHAPEL ROAD#3F
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: NEW HOME 3,400 SQ.FT.
ADD HEAT AND A/C TO NEW HOME.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
8/15/2012 10:57 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1200232 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER ELECTRICAL PERMIT
DATE: 07/11/12
GIS ID:34430150 FEE: 120.00
MUNIS APPLICATION# 201200697 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: T&H ELECTRIC INC. ADDRESS: 150 FRAZER FIR ROAD
ADDRESS: 570 FOSTER STREET OWNER: MANNARINO BUILDERS LLC
SOUTH WINDSOR,CT 06074 400 CHAPEL ROAD#3F
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: NEW HOME 3,400 SQ. FT,
WIRING NEW SINGLE FAMILY HOME.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
7/11/2012 8:40 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1200312 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER PLUMBING PERMIT
DATE: 08/15/12
GIS ID:34430150 FEE: 120.00
MUNIS APPLICATION# 201200697 BUILDING DESCRIPTION:
APPLICANT ;" LOCATION
NAME: IMPERIAL PLUMBING CO.,INC. ADDRESS: 150 FRAZER FIR ROAD
ADDRESS: 648 SULLIVAN AVENUE OWNER: MANNARINO BUILDERS LLC
P.O. BOX 875 400 CHAPEL ROAD#3F
SOUTH WINDSOR,CT 06074 SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: NEW HOME 3,400 SQ. FT.
DRAINS;VENTS,WATER AND GAS PIPING,FIXTURE INSTALLATION.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
8/15/2012 12:10 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE