Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
150 BERLE RD
r Ida 45erle Ac a4 Electric # ►loobLtog APPLICATION FOR BUIL IN ,r PERMIT Plumbing# ' HVAC# -, Date: Sprinkler# Estimated Cost $ FINAL APPROVALS Permit Fee $ /5� Building COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering TYPE OF PRINT ONLY Eng. Insp. Fee $ Affidavit - ► SIGN ON REVERSE SIDE Appr.for CO. Total Fee $ /Sb TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ 33/g The undersig d hereby applies to do work according to the following: Applicant ocation of work Lot N . Applica t' Addres Tel # Town Zip Lic.#j�a3�—� Owner Architect 5O ner's Address Architect's Address Zip Zip Sq. Ft.New Area: 1 st FI. 2nd FI. 3rd FI. Po al Ne Area Purpose of this permit fV1 Use City Water❑ Well Septic System Sewer 0 Ins: HO SP Cert. Area Basement Garage Approved by "`' ate " 11 1l Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed Signed 1 hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS �7 BUILDING(S) LOCATED AS SHOWN "ORrGAGE SURVEY s. PROPERTY or T NEREdrCERr/fr ro—,= rHA r THIS Am P /s sue s7r—A Wr-jA—L Eir—c5#—Wr—c'Y AND ZONING REGULATIONS ARE NOT viotArro. SCA L E: IN Fr DATE 00 46`1 • �STo"e WAA- . SroNb -71-54-05 = ZZ�.3 6 ZI.Zv t.1or'. Sr AJMVn P of �>J��zreyT�LeN-hevu►an l'o AREA = 49� 930 t�-� '" 12EvEer o R�cc�av Ow�.1EQ /fir = 1.\grCo I�G:� M �"l►•aE �o,�o IS ExTE.3oEC• PA.vew,ca.�t- Ta Bo 2EMovEpJ �¢6A. 1 UcwDeS Pa�mdV r i�pv►C�c 1-V��.► Ca" l.a•.*+. 89'r 5r�ep„ct e lu -ZS ' I- N =o� Nro o N : 12o cJo�-oo" Ra 60.00 A• 10 4.-7Z i to FOR BUILDING ONCT M. o. Bon uRg1/ I� H llrz' 0 r a t_ R L E. � O �-i Vi YQ7ARR►70�J N �. Esk-M • Ws *Q No.268a ] P.OP,...TY OF i"Y0 AUR` NO. R!,"RLE ROAD SOI'TH WINDSOR, CONN. BEING LOT NO . 21 ON MAP ENTITLED: " Plot Plan-Oak Grove Acres-Section No . I-Owner & Devol.eper- Carlo Prestileo-Berle Road & Christine Lane-South 1;'indsor, Conn .-By S .A .F.-D.A .S .-Scale 1 "=40 '-D;te : April '20, 1971 - Sheet No . 1 of 6 - Revisions : 7/14/71 Easement ." SC %L E 1 "=40 ' DATE: bti��L ZCo a1972 GRISWOLD-& FUSS INC . 210 MAIN ST. MANCHESTER, C,ONN. Q `To,6 4 3z - vo ::z DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# Oq 644-2511 ext. 230 — Date Building Inspec Application must be printed or typed FEE SCHEDULE � zg L /4�L ion of Job: $0-$1,000=$15.00 FTenant Street :No. t No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation A APPLICANT Ate do Amp St aIC P,S APPLICANT ADDRESS _9 D 64-"g D -t' 06096 APPLICANT PHONE# - /Ia,,-//�6 00 O W N S'It OWNER �[-`� RA FLll,*J� OWNER AD RESS /J O SMLe_ A17 Soy C 60 9 Qr OWNER PHONE Vlp o i k�(g- 9418/ C ESTIMATED COST$ /`I OO c). OO IS THIS A CONTRACT COST? !v �Yes —No LG G FEE ENCLOSED$ s; C-2 Q fNs O�y�� TYPE OF JOB: oR C New Installation .zAlteration/Addition/Repair 46 R evi seal 4/01/n nm APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING ❑RESIDENTIAL A/C ❑COMMERCIAL ❑VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL BEATING EQUIPMENT INCLUDING MAKE&MODEL NO.) ' jtwpubo /t r,-- r N C /U*01,5g5aE GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING UIP ENT(INCL G AI%&MO EL NO. 1�iUI� iJ P S/ '+ 2 X A C a L o23 TONNAGE _ COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) //�� //�1 � //� J� FURTHER DESCRIPTION OF WORKf401A (p/kCAA. /Y-I1t,L 0J,4A1lNC >� J4S/VjtIVJq C� THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 30303 Is ot- CONTRACTORS LICENSE NO. TYPE rS-T�ATE SIGNATURE OF APPLIC - DATE e/l ! 0 AIELL6 CORPORATE OFFICE P.O. BOX 548, WINDSOR LOCKS, CT 06096 HOME SERVICES Plumbing • Heating • Electrical •Air Conditioning •Water Quality Solutions 8 Lo 9 To Whom This May Concern: Aiello Home Services authorized Linda Dawson-Hayes, Russell Horrocks, Stephen Birch, Garrett Cardwell, Dave Arildsen, Tim Lynch, Joe Sparveri, Keith Tyler, Randy Weidig, Shawn Greenlaw,Melissa Marian, to pull permits for our company for any plumbing,heating or air conditioning replacement(s)or new installation(s). If you have any questions please call our office at 860-292-2600. This letter is for a permit for the property located at: /,5'0 �MLF, Cr 06094 01 Homeowner: ",b rJ 1< CAI_©Li5 AJ Permit Fee Amount: $ Sincerely, Michael Jezouit President STATEOF CC)NNECTICUTOF CU)NNECTICUT HEATING,PIPING&t:Zd,'j,._�TED CONTRACT umrrED sip*r* f6NTRACTOR MIC �t R 6UIT MIC'R (QUIT • 1g WIIVI? OR 1; ;CI' l6096 WIN I) It" � ' ET"�096 LI ./REG NQ, EXPIR S LIC. AEG N R IV +?; - EXPIRES N� HTG.0303032 S1 ?u, 08/31/2009 SHM.0005345-SMo / i¢( 08/31/2009 f SIGNED a���R=�-- ---- ---- _ SIGNED Local 860-292-2600• Connecticut Toll Free 1-888-956-4455 Fax 860-292-2690 Connecticut License Numbers • P1-203350 9 Si-303032 • E1-193730 01108 Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Aiello Home Services AC_Replace Windsor Locks CT 06096 Page 2 Pro'ect Report General Project Information Project Title: AC Replace Designed By: David Arildsen Project Date: Monday,August 17, 2009 Client Name: Bob And Carol Flynn Client Address: 150 Berle Road Client City: South Windsor, CT 06074 Company Name: Aiello Home Services Company Representative: David Arildsen Company Address: 600 Old County Circle Company City: Windsor Locks, CT 06096 Company Phone: (860)292-2635 Company Fax: (860)292-2690 Company E-Mail Address: d.adldsen@aiellohomeservices.com Company Website: www.aiellohomeservices.com Company Comment: The right comfort for your home. Desi n Data' Reference City: Windsor Locks, Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees Elevation: 169 ft. Altitude Factor: 0.994 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: -5 0 45 70 46 Summer: 95 72 50 72 23 Check Figures Total Building Supply CFM: 2,041 CFM Per Square ft.. 0.625 Square ft.of Room Area: 3,264 Square ft. Per Ton: 743 Volume(ft3)of Cond. Space: 26,112 Air Turnover Rate(per hour): 4.7 Buildirig L66ds Total Heating Required With Outside Air: 85,093 Btuh 85.093 MBH Total Sensible Gain: 37,934 Btuh 94 % Total Latent Gain: 2,535 Btuh 6 % Total Cooling Required With Outside Air. 40,468 Btuh 4.39 Tons(Based On 72%Sensible Capacity) Notes, Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. T:\Installation department\Load Calc-DaveWAAAAA.rhv Monday,August 17, 2009, 4:20 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.l Aiello Home Services AC Replace Windsor Locks,CT 06096 Pale 3 J Miscellaneous Report System 1 Main Floor Outdoor Outdoor Indoor Indoor _ Grains Input Data _ _ Dry Bulb Wet Bulb Rel.Hum Pryl3ulb _ Difference Winter: -5 0 45 70 45.89 Summer: 95 72 50 72 22.91 [Duct Sizing Inputs - -- - - - - - - -- - - - - -- - --- — — Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00030 0.00030 Pressure Drop: 0.0500 in.wg./100 ft. 0.0500 in.wg./100 ft. Minimum Velocity.- 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 600 ft./min Minimum Height: 0 in. 6 in. Maximum Height: 18 in. 10 in. Outside Air Data Winter Summer Infiltration: 0.426 AC/hr 0.200 AC/hr Above Grade Volume: X 26,112 Cu.ft. X 26,112 Cu.ft. 11,123 Cu.ft./hr 5,222 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 185 CFM 87 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 25.15 = (1.10 X 0.994 X 23.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 15.49 = (0.68 X 0.994 X 22.91 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 82.00 = (1.10 X 0.994 X 75.00 Winter Temp. Difference) uct o Sena o� or System_ " , . :; Attic uc Duct Surface From !2.._,Type Description Location Ceiling Leakage Insulation Area MDD 1 Supply Main Basement 0.12 0 442 No 1 Return Main Basement - 0.24 0 164 No T:\Installation department\Load Calc-Dave\AAAAAA.rhv Monday,August 17, 2009, 4:20 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Aiello Home Services AC Replace Windsor Locks,CT 060M P 4 Load Preview Report Has 70- AED Net Ton /Ton Area Gain Ga Sen in Gant Loss H Sen tg7CFIVI Act Size • CFM . Building 3.37 4.39 743 3,264 37,934 2,535 40,468 85,093 1,112 2,041 2,041 System 1 Yes 3.37 4.39 743 3,264 37,934 2,535 40,468 85,093 1,112 2,041 2,041 18 Duct Latent 587 587 Humidification 5,748 Zone 1 3.264 37,934 1,948 39,882 79,345 1,112 2,041 2041. 18 1-Living 1,632 16,993 674 17,667 38,878 545 914 914 1-10 2-Bedroom 1 1,632 20,941 1,2741 22,215 40,467 567 11127 1,127 10-6 T:\Installation department\Load Calc-Dave\AAAAAA.rhv Monday, August 17, 2009,4:20 PM 11000403 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 08/19/11 GIS ID: 10200150 FEE: 150.00 MUNIS APPLICATION# 201100935 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: NML CONSTRUCTION LLC. ADDRESS: 150 BERLE ROAD ADDRESS: PO BOX 207 OWNER: FLYNN ROBERT F&CAROLE L HEBRON,CT 06248 150 BERLE ROAD SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: TO REPLACE THE EXISTING ASPHALT SHINGLES WITH NEW ON THE MAIN HOUSE AND GARAGE. c k SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE,APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: F OCCUPANCY GROUP: BUILDING OFFICIAL 8/19/201 12:07 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE