Loading...
HomeMy WebLinkAbout143 BERRY PATCH BUILDING 9 Electric # 7 APPLICATION FOR BUILDING PERMIT HVACPlumbi# # ' 9 143 Berry Patch (Building 9) Date: n r T 9 -1r Sprinkler# lY(,-J FINAL APPROVALS Estimated Cost $�,�000.00 Building COMPLETE RED BOXED AREAS Permit Fee $ EngineeringOccupancy e TYPE OR PRINT ONLY Enns . F g. e $ 1O Affidavit p A r. for CO. IGN ON REVERSE SIDE pp Total Fee $ 3 4 D TO THE BUILDING D PARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant The Metro Cos nict i an ccnrp. Location of Work 143 P---= Patch Lot No. 2B Applicant's Address Executive Drive, Suite 100 Tel.# 860-674-5640 Town Farmington, CT Zip 06032 Lic.# M00.900434 Owner Berry Patch II Associates L.P. Architect Associated Architects Owner's Address 6 Executive Drive, Suite 100 Architect's Address 16 Spring Lane Farmington, Cr Zip 06032 Farmington, Cr Zip 06032 Sq. Ft. New Area: 1 st Fl. 896 2nd FI. ---- 3rd FI. ---- Total New Area 896 Purpose of this permit New Construction - multiple single family affor hl _ dwelling City Water[jt Well❑ Septic Systemo Sewer[A Ins: HO SP Cert. Area Basement Garage Approved by Date Use Group Construction Type Revised W02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. THE METRO CONSTRUCTION CORP. Signed 'Rnfr terR. n,Presidwi I hereby apply for a Certificate of Occupancy for the work described in this applicati the rm Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS RECOVED SITE COMPLIANCE CHECKLIST J AN 3 0 2006 TOWN of SOUTH WINDSOR, CONNECTICUT SOUTH 14'INDS20, P'ANNING DEPT. 143 BERRYfONSTRUCTION TCH LOT_# ��� Reviewed By Bering) THE METRO COR Date Reviewed 3c e( /Denied 6 EXECUTIVE DRIVE,FARMINGTON,CT Reviewed By Planning) BP_#_31264_ Ph_# (860)674-5641 Date Reviewe 1 a� pproved Denied Date Submitted 00/00/00 ***** FOR Gf o O **** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include Approved Denied N/A 1 Approved building permit plan 2 Finish grading per approved building permit plan 3 Site work; i e trees, shrubs, dumpsters, required parking 4. Utility location; t� a sanitary sewer/septic system b. foundation drain c electrical & telephone ✓ d. water e. btberGR5 5 Sewer connection charge paid 6 Appropriate certification t. 7 Bonding 8 Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. Pav Exc # COMMENTS <h'gtg— for S1 Inc e't Status �1 S&i- CPO V"i f P 4"' i` f, L�)L-� .r�C I � � ,-I I� l - SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 949 PLEASANT VALLEY RD #60_LOT_�� Reviewed By eering) MANNARINO BLDRS & RESTORATION Date Reviewed oved nied 1169 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By N)ft (Planning) BP_#_31684_ Ph_#_289-7055 Date Reviewed Approved/Denied Date Submitted 00/00/00 ***** FOR C of O ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A ✓ 1. Approved building permit plan 2. Finish grading per approved building permit plan / 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone d. water e. other 5. Sewer connection charge paid 7 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland wetlands Considerations ✓ A. Lighting c/ B. Signage % Freestanding Wall JC. Fee in lieu of Open Space Sewer Permit No. Pav Exc # COMMENTS: r�;-..S �� &-b"c( /(i-/ f 4 C�. -Irc Status: yns� PnoLe1S Pi1lGA K. �L��cl.�Cd I �'T �-�O/D�rN ^ [so LF it , r- rnau-c! � � �� � �� ��1 � d � 1Llez 2 173dc qlb Old 0.6 All -¢ - - It,u= ate: Look) volt �, Alrk If L s��� ,., 3 �• ` ` � " ,.._ S t � Fir a ' O � �r d 3`a yid • �a '�!k � D� `i �, i,� r.. rO �1S 1 't sF aZ c3 U� RVISECEiVED SITE COMPLIANCE CHECKLIST JAN 0 5 2006 TOWN of SOUTH WINDSOR, CONNECTICUT SOUTH` WINORILANNI 35 BRIGHTMAN CIRCLE LOT_# Reviewed By (EngineIVR ) RSK KELLCO Date Reviewed o �/Denied 1744 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By lanning) BP_#_32259_ Ph_# (860)644-8761 Date Reviewe / 4 App� /Denied Date Submitted 01/05/06 ***** FO BUIL G PERMIT - In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval The minimum requirements shall include Appro Denied N/A 1 Name, address & phone number of owner/applicant 2 Name, address & phone number of plan preparer 3 Zoning Information - i e zone, open space, floodway, street address 4 Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc r/ b. Easements of record c Lot description, bearings, building lines, / distances, area, etc d. Contours, existing & proposed, 1 or 2 ft. / interval where appropriate ✓/ a Building location with dimensions Elevations of proposed finish floor, garage / floor & centerline of road at driveway f Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street g. Tentative utility location (gas, water, / electric, septic system, etc ) � f/ h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements (P.E & L.S.) 5 Sedimentation and erosion control /P? _ 6 Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS NOTES: 1.THIS MAP IS DEPENDENT ON THE MAP REFERENCED HEREON. 2.THE BUILDING LOT SHALL DE LDAMED,sEDm.AND wxCNED wITH sTRAw PRIOR To ISSUANCE OF G0.(F THE SEASON DOES NOT PERMIT SEEDING THEN THE LOT MUST BE STABILIZED VATH STRAW OR EROSION CONTROL NETTING TO PREVENT MINTER AND SPRING EROSION).PROPERLY INSTALLED EROSION AND SEDIMENT CONTROLS MUST BE N PLACE TO CONTROL ANY EROSION AND SEDIMENTATION PROBLEMS.THE BUIDER/OwINER IS f R/ / RESPONSIBLE FOR ALL STABILIZATION REOUIttIA NIT_. ., Ilk ICY />// 1 / 1 ! 3 ROOF LEADERS TO BE DISp1AR0ED ON SPLASH PADS �� t t J� -i I 1 I 1 I 4 ALL ROADWAY UTILITIES ARE TO BE INSTALLED N COMPLIANCE MTiH THE APPROVED 'BRIGHTMAN CIRCLE' Z F I VISION PLANS. 7 I I 1 I S FINISHED GRADING AROUND THE HOUSE SHALL ALLDw A 3 INCH DROP IN GRADE AT A DISTANCE OF 6 FEET FROM THE FOUNDATION AS SPECIFIED IN THE STATE OF CONECTICUT BASIC BUILDING CODE. , I 1 I I 6.PARCEL ZONED AA-30. dBp 7 BACKWATER PREVENTION VALVE wmH SURFACE ACCESS SHALL BE PROVIDED ON THE FOUNDATION DRAIN. Tr 33 / DBL ! / IN k 186 8 TF.196.90 , 3 REFI]tENCE NOTE ' IN 1�t 6. 1NV(1CB4OU*190.07 , SILT FENCE (1 YP-) , / / 1.52' / I NI BOUNDARY AND TOPOGRAPHIC NFT]it11A110N ARE TA102N FROM PLANS ENTITLED / p ! a 1 roul� ,/ / / 1 'BRIGHTMAN CIRCLE.CONVENTIONAL RE-SUBDINSION. MILLER ROAD& r C 8 N 'x190.80 r ` N87b9',� 33jrW —_` N=ro6'o5'E // ; ��N �WVAN NEVERS ROAD.SOUTH MNDSOR.CONNEC ICUT.PREPARED FAR RSK-10:].L.COL NC. , 219�93 / / 19286' BY DESIGN PROFISSONALS.INC,DATE OCIAEEIIt 27.2004 REV TR 0.I/2S/OS. , , N STREE TRty TO NIP SHEETS 3-9. _ _ _ _ _ _ _ _ =r _ ! FAVOR OF bF WINDS r a LEGEND t 11 / I 70.pp• 20' S.Y. 30,120 sq. ft. �L/ O IRON PIN TO BE SET 1 / 2 �4A0 0.69 acres 0 MONUMENT TO BE SET / 1 ! //o S o _ =(TI: = EXISTING CATCH BASIN AND PIPE 7 , f CI; C• N / / // , / - $ - EXISTING SANITARY MANHOLE AND PIPE T / 0 1 1 0 1 v t.00 293.85 S—PROP. 6A SAN. LATERAL S=2i MIN.S SERVICEt 3/ rn Ilrf 2 ; 4.24 —w—PROP. WATER SERVICE ( ) / c1 PROP. HOUSE X 203.6 i — \ If 1203.35 i—PROP. 6' PVC SDR-35 FND. DRAIN (S=1.0% MIN.) 2 10 X f1 a f 05.85 1 / -3aO- EXISTING CONTOUR \ / D ,► d 1 o TO*.204.85 204.00 -�-PROPOSED CONTOUR 1 ,1 ��♦ ! G:203.85 M." PROPOSED SPOT GRADE 1, ♦ r. �. / ' I // // / 1�1 / EXISTING TREELINE ^^'•"^^^^^ PROPOSED TREELINE / // If ` '`r \ X 203.40 /// EASEMENT BOUNDARY SILT FENCE ,, h / / Ell / It +J� ��•• I g / 02.75 . z / 1jI 198.82( � Awat rom 1.w l ram rwo z MILE x ell SMAI 7.4 ou wr A 6- w1pgN atop A x , \? 1 / / / / V wrsorc �* oo v x rest TF:N98.81 $j7• 1 0' / IN/P I�r want[nor row:ww: ��(J r o i� 1o.oa INY6,189.91 I i{f S 1 / / / / JOIN Vr h. 60rf arAw..a. 1 j C147 / -•'cilG7" ' ��q��• p C 1, �-AiYll-IKAV__Ul1'Ili FAD ��r 6 "�L'«2' STONE OVER Sg3�Ob. / Pam• a ATTAW Ft"r#AW TO a 11.0ou x f, ' BENDY? I FILTER FABRIC �,�• Ti EEUNE awn x wg0pfll ►OM Are EX10C wwOM"C rACr / ..sae rt s,o wI[w1ta1 x waaw.wm saA. 1 f I ow �.. C808 CONSTRUCTION OF SYNTHETIC FILTER BARRIER N.T.S. 1 1 THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-300b-I THRU 20-300b-20 , 1 1 / 1 ► 1 l / / �^ 1 s+° /� OF THE REGULATIONS OF CONNECIICIIT STATE AGENCIES- 'MINIMUM STANDARDS FOR SURVEYS AND MAPS IN t / / ', `� THE STATE OF CONNECTICUT' AS ENDORSED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. AND CONFORMING TO HORIZONTAL ACCURACY CLASS A-2 AND VERTICAL ACCURACY CLASS T-Z 1 1 f ► I 1 / / r , �� `' •G KNOWLEDGE WD BELIEF THIS MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. �� 4 12882 1744 ELLINGTON ROAD RICHARD P. MARTEL UC. No. SOUTH MIINDSOR, CT 06074, TEL (860) 644-IS161_,,�' F` . Tel. 860.291.8755 Fox 860.291.8757 DEPENDENT RESURVEY PREPARED FORS 1.UNLESS O!"OrwSE NOTED.COSTING UTUTY REVISIONS GRAPHIC 'SCALE Q� (�/1/A rp� LOCATIO BE NS AS FIELD VER ARE LASED ON eslgn LOT ¢ IS®1�9�U UVdl1IV Yi/llhllr AVAUIBLE MFOMA110N.ALL COSTING UTIUTIES RIOR TO CONSTRUCTION. 40 D 20 40 B ,A CDISMITES ARE SU V STAlPRIM To FIELD rofessionals, Inc. of a A LICENSED LAID SURVEYOR PRIOR i0 mm BT` RM/ .RIB At7.. 19AF 3.THIS P M . civil enalneers • planners • surveyors 35 13PJG �TMM CIRCLE .CLEJ.MS vtntr IS wuvALD MINIMS$R BEARS THE or SSIONWRESSION SEAL K° R ORIGNAL��. NO. DATE DESCTJ,now 1 iIIC)lL = ¢0 it Isndecspe architects • or •Cps SOUTH WINDSOR CONNECFICUT or laBs a11r 12-16-o5 BY t65 South Sotetlite Rood Southndeor Conneetieut 06074 South Windsor BUILDING DEPARTMENT i i fU THE This certitlr0 that this Plan and th speutc too copies et e proposed building or alteratio,s t.. Lvr9 try J together with amene + filed with Plan Ants stated in apPlicaticn J 8uilding and stat�to a`rI a to comPly wfth all 2.r". issued b wil s and :uch orders as shalt Jt this aPP iesfioo r and 1eAarimer,2 Q wing Pend-,,, Permit. f;nal issuauoe of a baildln. Srgned :his Plan is apprc,VCd �UiJJ.0 ,rders and crdin " t to a t>le ecnc rfion tho�ers r2g4t.,[;nd t L'1!Clrg shall 4. {If•J :,ah •o�detfunally APProved � Tteu tiled x iLh 'f vel ding Ins Pcctor ------ ---_ CI« y RECE INJED J AN 0 ,. 2006 SOUTH WIhDSOR ENGWEER'ING DEPT. BUILDING INSPECTION DEPARTMENT TOWN of SOUTH WINDSOR, CONNECTICUT C E R T I F <'`Ca fnO'<C a PAN C Y k-7 `• ZONE as r ' /r s a Kry.Y°".,� ` f ' >y January 25 20R6 w a•w'0! ,..�' ` ,i,,4-.4 This is to certifyjthat-'1,4"3�8ERP}y B TC $RRCTED un3er�permit v...w 4. No. 31264 conforms gukaBtaiii�I'3ji �a; he�regtiretiti�tsof tke Connecticut Basic Building code°.anc'.rh �sr�in� regul��iona G ,.Che,"kTC4i#� f g r:..y_x3 /i^ N9MK1➢xAr • e0 ..y:,: y South Windsor anf$aj,9, eie i y appzg3te�lK. -faz`''�e—Z—cupanc s:indicated below Approved for Ocupancy L�ri3LTI-51 �+ wgAMLY DWEL&Ik �*�_ ax"c`g Use Group R3 "''� �' �•', � ts< f3 g r ""'' «° >�-..✓"'..�;,..t f."S` x.::,' : t. � a add� Constr. Type: 5B "y.:,::"y,, BttidiapOfficial Notice If this ce*�tificate1 l. }�osCF'i^ des�roy. d, aR,duplicate should be obtained°imediately°fYomtK€�Bu2di2fg,Department Any change or extensibrt,.�f he us hereYn approved requires a new certificate of�occupancy. Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-31264-B 22,000 BO1 FOOTING 05/19/05 CJD A BO1 FOOTING 05/18/05 PJP A BO1 FOOTING 05/25/05 CJD A **-1467-5 2,000 **-12591-H 6,000 **-11823-P 5,000 **-19387-E 2,700 O� Total Est Value 37,700 Dwelling 896 45,024 00 Basement 0 0.00 Garage 0 0.00 Smoke Det 3 225 00 BOCA Value 45,275.88 Difference 7,575 88 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: 02 S�1 BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#/ 2 7 005 644-2511 ext. 230 3 Y Date Building spector Application must be printed or typed FEE SCHEDULE Location of Job: 14 3 SLY Patch 2 B $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad BrOok, Cr 06016 APPLICANT PHONE# . (860) 623-1991 OWNER _Berry Patch II Associates Limited Partnership OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr. 06032 OWNER PHONE (860) 674-5641 C ] ESTIMATED COST$6 ,0 0 0 . 0 0 Z. IS THIS A CONTRACT COST? %Yes _No j ��d FEE ENCLOSED$ 9 0. 0 0 ds TYPE OF JOB:OR-Co�� X , New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: ®HEATING D(RESIDENTIAL *A/C ❑COMMERCIAL ® VENTILATION 0 INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC SXWARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE---___OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) ---- Magi-c Pak M/N 51HWC?43A-7 Armstrong-- --- - ---- GROSS HEATING CAPACITY(INPUT-BTUH)51 ,000 NET RATING(OUTPUT—BTUH) 40,000 TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION :0 INSIDER OUTSIDE CAPACITY ® GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF P e r TOTAL HEAT GAIN(BTUH) _(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) Plans DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) & Specs TONNAGE 2 COOLING CAPACITY(BTUH) 24,000 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 303755 S-1 CT CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICAIrIT DATE O DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 - ate Bldg.Permit# F L w cto nsp t r Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 3 4 3 ��Y Patch 2 B Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT ThcmaS L. Jacquel c/o AllState Fire Sprinkler, Inc. APPLICANT ADDRESS, P.O. Box 2350 Hartford, Cr 06146 APPLICANT PHONE# (860) 246-7711 �0 N SFq OWNER Berry Patch II Associates Limited -Partnership J. OWNER ADDRESS 6 Executive Drive Suite 100 \\ r a FarminCiton, Cr' 06032 OWNER PHONE (860) .674-5641 ESTIMATED COST$2 .0 0 0.0 0 IS THIS A CONTRACT COST? X Yes _No FEE ENCLOSED$_3 00 SO R.C O�� TYPE OF JOB: R New Installation Alteration/Addition/Repair P—i—A A/1T7/Norm APPLICATION FOR SPRINKLER PERINUT (Continued from reverse side) TYPE OF BUIL DING TYPE OF CONSTRUCTION 5B USE GROUP NO. OF STORIES M RESIDENTIAL ❑BUSINESS IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑MERCANTILE ❑ EDUCATIONAL CURRENT USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ❑ STORAGE ❑GARAGE ENGINEER'S NAME David R- Thanpsm PHONE(860) 246-7711 ❑MI MD USE (Other please specify) ADDRESS P.O. Box 2350 CITY Hartford STATE Cr ZIP 06146 KIND OF INSTALLATION SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI) ARE SPRINKLER HEADS ALTERED? C3 YES ❑NO IF YES,CHECK ALL THAT APPLY: ®ADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) 3 PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES 04 NO IF YES,CHECK ALL THAT APPLY: ❑FIRE ❑BOOSTER ❑OTHER ARE STANDPIPES PROVIDED? ❑YES ®NO IS A SPRINKLER SYSTEM PROVIDED? YES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP NIA PSI DESCRIPTION OF WORK New fire sprinkler system in two bedroom unit THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED ANTI)IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. F10590 Fire Sprinkler CP CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE 0 'fin 644-2511 ext. 230 BldJg• Pe rmit # ?tom uilding Inspect Application must be printed or typed FEE SCHEDULE Location of Job: FDesignation wry Patch $0-$1,000=$15.00 Street 2B Over$1,000= Lot No. $15.00 per$1,000 or any fraction thereof Apt.No. APPLICANT J—Electric APPLICANT ADDRESS 8 Sanrico Drive Manchester, Cr 06040 APPLICANT PHONE# (860) 645-9891 pW M SC.q OWNER Berry-Patch II Associates Limited Partnerslilp < OWNER ADDRESS 6 Executive Drive, Suite 100 � F , CT 06032 OWNERPHONE (860) 674-5641 ESTIMATED COST$ 2,700.00 IS THIS A CONTRACT COST? X Yes _No 4 f4� FEE ENCLOSED$ 45.00 ��S•Q R,C O�� TYPE OF JOB: X New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A 3 RESIDENTIAL BUILDING PERMIT APPLICATION? ❑YES ElNO ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑ MERCANTILE FUTURE USE AND OCCUPANCY Residence ❑ EDUCATIONAL ❑INSTITUTIONAL g�/� Fla; T;,,,, (860) 257-3968 ❑FACTORY ENGINEERS NAME PHONE ❑ STORAGE 203 Briarw ood Court ❑ GARAGE ADDRESS ❑MIXED USE CITY Rocky Hill STATE CT ZIP 06067 (Other please specify) TYPE OF INSTALLATION/WIRING METHOD NMC SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS 02 Al NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8 NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23 NUMBER OF LIGHT FIXTURES 9 NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS 1 SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Interior wiring of apartment to include outlets, switches and their cover plates. Wiring of appliances and HVAC unit. Install light fixtures. Install 100 amp breaker panel. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 123580 E-1 Cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR / l BUILDING DEPARTMENT l PROV 1540 SULLIVAN AVENUE DE 2 3 2004 644-2511 ext. 230 Bldg. Permit �`# Date Building Inspect Application must be printed or typed FEE SCHEDULE Location of Job: 143 Berry Patch 2B $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, CT 06016 APPLICANT PHONE# (860) 623-1991 Ow N SFq OWNER Berry Patch II Associates Limited Partnership < OWNER ADDRESS 6 Facec.-utive Drive, Suits 100 � . Fannirx ton, Cr 06032 • �, , OWNER PHONE (860) 674-5641 O C ESTIMATED COST$ 5,000.00 IS THIS A CONTRACT COST? X Yes _No FEE ENCLOSED$ 75.00 s, O�� TYPE OF JOB: O R•C X New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDIING IS THIS APPLICATION ASSOCIATED WITH A ❑RESIDENTIAL BUILDING PER11IIT APPLICATION? ❑ YES ❑ NO ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑ CA��I ONAL LE ElEDU CATION FUTURE USE AND OCCUPANCY EDU ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑ GARAGE ADDRESS ❑MDOJD USE (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4" NO.OF TOILETS 1 STYLE Elongated NO.URINALS N/A STYLE N/A NO.OF BATHTUBS NO. OF SHOWERS 1 NO.OF LAVATORIES 1 NO.OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3 AREA OF ROOF Back NO.OF CATCH BASINS N/A NO. OF FLOOR DRAINS 1 Kitchen NO.OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES IN NO SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4 Weil Mclain WATER HEATER: TYPE Indirect rest MANUFACTURER P/US 120 DESCRIPTION OF WORK I'HE UNDERSIUNED HEREBY APPLIES FOR A PERMIT TO PEKFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P-1 00204480 P-1 Cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE Location of Job: AFFIDAVIT Additional Fee S 155. 00 State of Connecticut ss.South Windsor County of Hartford j Owner I C.t 1i1( 1 G�. 41n of 04y-` = Ltit S /'Vc L)Vt Agent for the building erected Contractor under Permit No. 31264 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work autho ed u r said permit was Signe Subscribed and sworn to before me this day of A.D.20 Estimated Cost$ 2 2, 0 0 0. 0 0 Difference: S 7, 575.88 Notary Public IINZ)IALLjJLZ.0 tstNW II '-'1�^ V `/ $ $123g. x ° �.,�V� /N 1/ CAS I w t2to' .0. $ / "s INV:121.99(SW) II \ P /{c# Zoo o Ekfs N) 2°p' \ 2q,1z � L.P. 1 TF: g Z FF 1'OPG B(l/Lfl/ 14C / \ IINV.' 2•3B 11 \ F O Q P�A'''m� INV;125. tee. 0( 2s.cb FF 141, NG g \ �• z Z 11 \ PAnp V CO 8 / Igy:125 S BO�OM:131 CAry CDV PATbe 12°p W PAm n /LP.// M. 4$ QfC I\ - - i 12�• ` C. Vll no $ P� FENCO '� +,�0 �....•�•� - - _ '• • c2 I g �s PAcavpc l Il P C.D. LP. - Ca II 12 PA II P"np / A� P �T30 ELEC I 81T.WALK L.P. }I 0p �k !r TEL i �, 8 .7 8 PAm $ _z rn 1200• � 121° W. LAP.. wS a CA TV b S� TH^ /- EX. CB 14 1 �"I�� °Aib M / Pik'` ry ,� $ r "� PAn � f3.f°• l 71` 1 ILL4�j� N/1- C TF:135.58 $ r j / f/ PAwxc 1a n0 0p" - ii S PAnp V G I INV:132.23 M v If "0 °p TELE rI r '`.� pa c G o o l 1 r c° a ° Am P TF:1 s CATV EXISTING BUILDING #2 MI 1 1. e�/� PAnp tim N o2 yh °Aa t INV: 2 .2 15"/rS) EtEc FF TOP:140.73 ED p `/ KC AN W 14 4 h P , O j7 M INV 1 5.1 (15,/N) FF BOTTOM:130.90 N •\ `�`` off_ AR TNERS//•.���/'� C pUR T CO {t I L.P. C t210 11/ PA a •' OD^O 1210 P !( $ pW 43.30' ENCO S/6 �ha a' • Ill" W"�0 ' =p.� ?. M1 "N c<+w 6 (' `I >`6 p P"np j Pm 1,5 t2.00' �k 2810. b O C O R' N QI �7 N C PATp28. �`` j OCUMP PAD D 12 t21p P C may// f Pp� Q N y AM PAPA i PA, U ` �� 0 , \� GAS fA / ' ,� 9�/'/i� m `•\ ELEC� fk Wq fR A/N MAIL e0x LP \\ "6 ,2p0, m"TV,.� tl a'p 12.10 1 mNC I ` \_ \ CA TV `• T Mql NAIL BOX\\ P O^p 11 z 11 PAm RY L \\ fQ O0 L.P. t220' PAm �� �Qk N ` 00] ' 1 O r.w \\ EX. CB-i 12°D ro k om AP no me w I \ 25 \ S. !/ PAm `� a TF:137.14 `- ` IP •� `` OF INV:132.79(SW) � 1f rP�• 1200• 1 PAm INV.132.39(12") I �� \ '`II `"1\ `y`\```` r `� , \ \ \ \ •E�Y � � Gg IP ETFX:.1 1zPAfoINV-132.09(NW) YD-\29 3 12.20EX. SMH INV:126S 40.21 � � NV: wAiKJ76•28, S �E)5 0:2 : NV: WALK a> EX. CB-9 INV:124.4i;w INV:126.7 (S) S q 0)O_MH IN INV:126.81(6" MnEX. CB-8 TF:143.43 .I26.60(N) m v d+ �•� �- �� Fk, \\ TF:136.19 ^! J I ` INV•143.43(S) ,, :NV:127�1106"W) \\ \ r3-8" GVOLRMgf1v BIT w" LP. \\VV:132.39(12") 1RW3Q.53 N I \ TF:143.62 �` S,6, ^� HANDI-C INV;140.52(S) �,,, ° O� �� slcN IZ10 5z~�fa EX. CB-10 y, -s+•.. LP. c W� 7� E 02(N) I9 TF:138.04 \ 1 ' «� INV:14O9 ``` dC �p� I \` INV:135.64(W TEL. (;,A TV `h03• r\1' .� IN\1135.44 \ Ip ii X. -11\ Fk Wq Ex. GAS TF:145.53 \\ T? ��, `` INV: 6.91(6" �_ 1fR yglN MAIN I EX. CB-6 ` _ INV 133.31((N) IF. !r INv:13sa3(s) \ ^ 8"x2" TYTON PL �' IN .133.31 (N) �� \ `_ �- 1`` I N 7. I INV.137.53(W) oe ��` & BLOWOFF ` .525- BEND I �Y BLOWOFF Zz ` ZZ �AL 400e DI, ;TER w 8x6 ANCHOR TEE \ X. _ Ex. c6-12 / / 6" GVOL HYDRANT 'EX. YD-6 \\ y2p• TF:14 - 1F:144.51 IP `1 Ly TF:143.80 CLEc NV: (S INV:SILTED(W) (CWC TO SUPPLY) I / INV. \\ cc1oo°uE I s2 r 0.28' SOUTH OF "► I / INV.138.20(E) CAry .141.47(N / / INv:141.00(S) \\ 9 N PROPERTY LINE r EXISTING BUILDING # v:1a2.o7(Sw tt / c'0' s FF TOP: ti E B FF BOTTOM.148.81 T3.- t2t // / N/FR l3 y INV. 9.43(S) V KAREN A. & E DWARD J. c -a C - o O'CONNORIELE EXISTING BUILDING I.P. 00 0 1 7: .07 CAry FF TOP:156.84 Ex. YDT7 t2 I ° tt �_r 1 TF:NOT�'O G DE ° t2P tl N c- 1\ INV.139.07(S)) FF BOTTOM:146.97 INV.1401.113(S) I :139.07(E) W � 'INV:139493(N) 121 _ T"� ql 1 p 11 00 � 11 _..t" '\\ o� t24 fa OHO' II O \\ V 121 Obi Z Oa I I Y-^,0,.m I I a(o_ I I c2 v 121 li X LL III CB-1 1 �G, o3 12 Zco 4 u- I.1 I I :148.55 I \ Z,6 CO 1 y' 0 j21 11 I v'142.Ed(sE \ ��p tr- tt "" �L f%, - - I V.142. N) '1 (.0�'ft-.• - z a F- tt m '.2 12." C 4 8 I V.,142. S(W \\\ Z p O r O0 0 O '�.� 1's3 Ex. CB-10 POOZn.r >A' f� � TF:146.76 \\ WI�A-� WwlLLi. 11 NOm 121• 1-l��1 ,_>.` INV:145.16(W) 1 ; 3� tt WALL 121' / • \1 w \ AS 1\ EX. YD-3 VA / N TF:NOT TO GRAI E V.SILTED 1 `� ,. ' EX. CB-2 GREGORY & MICHELLE TF:151.79 EX. CB-11 INV:SILTED / ^� BASSOS 37 TF:148s8SW) r » - - - - - - - - - - - O e ^ t�/1 I V:144.78(SE) _ _ _ - - - - - V L N HO I lam • \ TF:151.81 \ INV:148.71(S) / NOTES: INV:148.56(N) �\ :154.00 `-\ c -- N87'5444"W 1. THIS MAP IS DEPENDENT ON THE MAP REFERENCED HEREON.. INV:149.00(N) �� \ 508.51' -' _' _____ - - \ i 2. THE PURPOSE OF THIS MAP IS TO DEPICT EXISTING CONDITIONS AND EXISTING BUILDINGS. l \ \\ +n / �� 3. AREA OF THE PARCEL = 230,238f SQ. FT. id IN \ \ \ ^� PARCEL 2 - 5.28f AC. / z z \ - �\ I / o o \ AREA - 230,238.5 S.F. 4. GROUND OBSCURED BY SNOW COVER AT ANENT NT TIME OF SURVEY - WATER -- -- ; 5.28 AC. LOCATION BASED ON INFORMATION SUPPLIED BY THE CONTRACTOR. N _N \ / �/ � �► ' � �\ Ogg 3 (NON- ISLE/ �\ � -� MAP REFERENCE: �3e 6 NON-ACCESS ARSE �` / � � � 1. TOPOGRAPHIC PLAN, PROPERTY SURVEY/RESURVEY PREPARED FOR: BERRY PATCH II, GRANDVIEW�21 \ _ TERRACE & DEMING STREET SOUTH WINDSOR, CONNECTICUT SHEET NO. 4A OF 11 DATE. 11/04/03 REV. 6-7-05 SCALE 1"=40' BY DESIGN PROFESSIONALS INC. \ `- fill / 40� O \ \ N 40, o II n 1. UNLESS OTHERWISE NOTED, EXISTING UTILITY REVISIONS THIS SURVEY HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-300b-1 THROUGH 2O-300b-20 Tel. 860.291 .8755 DEPENDENT RESURVEY PREPARED FOR: SHEET z LOCATIONS AS SHOWN, ARE BASED ON AVAILABLE OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES - "STANDARDS FOR SURVEYS AND MAPS IN THE Fax 860.291 • 8757 m INFORMATION. ALL EXISTING UTILITIES SHOULD STATE OF CONNECTICUT" AS ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. THIS GRAPHIC SCALE eS1 CV �,OCAMob PLM BE FIELD VERIFIED PRIOR TO CONSTRUCTION. SURVEY CONFORMS TO HORIZONTAL ACCURACY CLASS A-2. 40 0 20 40 80 g BERRI` PA TCII II 2. ALL UTILITIES ARE TO BE STAKED IN THE FIELD TO THE BEST OF MY KNOWLEDGE AND BELIEF, THIS MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. 1 BY A LICENSED LAND SURVEYOR PRIOR TO Crofessionals, Inc. CONSTRUCTION. _ ( W FEET ) DESIGN.KMl DRAWN.•DUG CHECKED: RPM ( ]�gAN� ��y '�'�Il$�g�� A�`� �y� (UN(� S�'�g�E'�' 1 inch = 40 ft. civil engineers • planners • surveyors 3. THIS PLAN IS INVALID UNLESS IT BEARS THE 12882 '" landscape architec*s • gis gps ✓013 NO.: 1823 DATE.• 12113105 � +{w�a ,ry�Trw IMPRESSION SEAL AND ORIGINAL SIGNATURE a�(D llH WU1�71i SOR C®1�71�7 ICllE\1.rlV Ji OF THE PROFESSIONAL ENGINEER/SURVEYOR. NO. DATE DESCRIPTION BY RICHARD P. MARTEL LIC. No. 165 'South Satellite Road, South Windsor, Connecticut 06074 DRAWING NO.: bbs-stakeout 1823 1823-base-ab.dw ay lS/1l 1�71s�' y D South Windsor BUILDING DEPARTMENT f0 Tat _. .. L'. yr ,o, q,;, rbis Cert-fi, anJ ;pec: .. anpi•aa of the prvp.'­a uullding or aa. • . eructed at ,a Z cif �.!-•mod'" '�//'�L/A /y� r� together witf, am,id. ,is stated in .ir,,i. J filed with pl.,n and i .„r,a to Comply . Building and st.:tr- + and such ord rs — . t issued by the 3ulidiag Department during pen.: I of this appliedtion and final 1$tuancii of a buiir:n4 permit. Signed This plan is apvrv-d wbjcct to thF- conditlon t*,1` orders and ordinant,s regulatink building shall ,p Compiled with. PSUydltionaily Approved These filed with e f I�#rndTrly 1#tapeaor tier, D CNN 0 2006 WEERING DEpr