Loading...
HomeMy WebLinkAbout14 BERRY PATCH BUILDING 2 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT # Application is hereby: TOWN OF SOUTH WINDSOR PERMIT ERMIT# BUILDING DEPARTMENT APPRov 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg. Permit# zqatA Building Ins or Application must be printed or typed FEE SCHEDULE Location of Job: 14 Berry Patch 2R $0-$1,000 $15.00 Street No. Street Lot No. Over$1,000= ' $15.00 per$1,000 14 or any fraction thereof Tenant Designation Apt.No. APPLICANT J—Electric APPLICANT ADDRESS 8 Sanrico Drive Manchester, Cr 06040 APPLICANT PHONE# (860) 645-9891 0* N SF OWNER Berry Patch Associates Limited Partnership OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr 06032 OWNER PHONE (860) 674-5641 C / ESTIMATED COST$ 2,945.00 0.4 x � � IS THIS A CONTRACT COST? X Yes _No Q } �� FEE ENCLOSED$ s O�� TYPE OF JOB: OR C X New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERNUT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION? OYES El NO ❑BUSINESS CURRENT USE AND OCCUPANCY U ASSEMBLY ❑MERCANTILE Residence ❑:EDUCATIONALFUTURE USE AND OCCUPANCY ❑INSTITUTIONAL � ❑ � Engineering FACTORY ENGINEERS NAME PHONE (860) 257-3968 ❑ STORAGE 203 Briarwood Court ❑GARAGE ADDRESS 0 MIXED USE (Other please specify) CITY—Rocky Hill STATE Cr ZIP 06067 TYPE OF INSTALLATIONIV;HUNG METHOD NMC SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS 02 Al NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES 0 NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8 NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23 NUMBER OF LIGHT FwruRES 9 NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS 1 SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Interior wiring of aparbuent to include outlets, switches and their cover plates. Wiring of appliances arxes and HVAC unit. Install licit fixtures. Install 100 amp breaker panel. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 123580 E-1 Cr CONTRACTORS LICENSE NO. l , TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 3�� BUILDING DEPARTMENT OVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 a� C� Date Bfing Inspector Application must be printed or typed Location of Job: FEE SCHEDULE 14 Berry patch 2R $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 14 or any fraction thereof Tenant Designation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# (860) 623-1991 O W N SF OWNER Berry Patch Associates Limited Partnership q< OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr 06032 O = r OWNER PHONE (860) 674-5641 C ESTIMATED COST$ IS THIS A CONTRACT COST? X Yes _No �L 4G FEE ENCLOSED$ C�7s TYPE 1, OF JOB:SOR•CO � x New Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? D YES 0 NO O RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY U ASSEMBLY 0 MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4" NO.OF TOILETS 1 STYLE El«mated NO.URINALS N/A STYLE N/A NO.OF BATHTUBS NO. OF SHOWERS 1 NO.OF LAVATORIES 1 NO.OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3 AREA OF ROOF Back NO.OF CATCH BASINS N/A NO.OF FLOOR DRAINS 1 Kitchen NO.OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES 01 NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4 Weil Mclain WATER HEATER: TYPE Indirect rect MANUFACTURER P/US 120 DESCRIPTION OF WORK THE UNDERSIGNED HE AIT TO PERFORM THE WORK DESCHI F ANDISTO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P-1 00204480 P-1 Cr CONTRACTORS LICENSE NO. E STATE OC T t s nM SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR �� BUILDING DEPARTMENT 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 ate uil i Inspector Application must be printed or typed FEE SCHEDULE Location of Job: FTenantDesignation Berry Patch 2R $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 14 or any fraction thereof Apt.No. . APPLICANT Thwas L. Jacquel c/o Allstate Fire Sprinkler, Inc. APPLICANT ADDRESS P.O. Box 2350 Hartford, Cr 06146 APPLICANT PHONE# (860) 246-7711 O W N S 4t OWNER Berry Patch Associates Limited Partnership t OWNER ADDRESS 6 Executive Drive, Suite 100 r r.; Farmington, Cr 06032 M OWNER PHONE (860) .674-5641 UESTIMATED COST$ ( (7.0 O IS THIS A CONTRACT COST? X Yes _No �G FEE ENCLOSED$ OS- OR.CO TYPE OF JOB: X New Installation _Alteration/Addition/Repair De..:. A A/Al//')AAq APPLICATION FOR SPRINKLER PERMIT (continued from reverse side) TYPE OF BUILDING TYPE OF CONSTRUCTION 513 USE GROUP NO. OF STORIES M RESIDENTIAL ❑BUSINESS IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PERNUT APPLICATION? ❑YES ❑NO ❑MERCANTILE ❑EDUCATIONAL CURRENT USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ❑ STORAGE ❑GARAGE ENGINEER,S NAME David K- ThompSon PHONE(860) 246-7711 ❑MIXED USE (Other please specify) ADDRESS P.O. Boat 2350 CrI'Y Hartford STATE Cr ZIP 06146 KIND OF INSTALLATION SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI) ARE SPRINKLER HEADS ALTERED? Of YES ❑NO IF YES,CHECK ALL THAT APPLY: ®ADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) IN PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES 00 NO IF YES,CHECK ALL THAT APPLY: ❑FIRE ❑BOOSTER ❑OTHER ARE STANDPIPES PROVIDED? ❑YES M NO IS A SPRINKLER SYSTEM PROVIDED? W YES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP NSA PSI DESCRIPTION OF WORK New fire sprinkler system In two bedroom unit THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. F10590 Fire Sprinkler CP CON7RACTORS LICENSE N TYPE STATE 7 SIGNATURE OF APPLIC DATE Z7 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 1 SC1 BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE ll 1 3 644-2511 ext. 230 Bldg.���# Date Bui i g Inspector Application must be printed or typed F:Tenant Location of Job: BLDG 2 FEE SCHEDULE Berry Patch $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$l,000 or any fraction thereof nation Apt.No. APPLICANT J-Electric APPLICANT ADDRESS 8 Sanrico Drive Manchester CT. 06040 APPLICANT PHONE# 8 6 0-6 4 5-9 8 91 S OW N St OWNER Berry Patch Associates Limited Partnership OWNERADDRESS 6 Executive Drive QFarmington CT- 06032 OWNER PHONE fi60-674-5620 x5641 C _ ESTIMATED COST$1 0 ,0 0 0.0 0 xx IS THIS A CONTRACT COST? X Yes _No FEE ENCLOSED$ /SU 1� TYPE OF JOB: DSO R C 0 — New Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? 0 YES 0 NO :I RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FU.I.URE USE AND OCCUPANCY Residence ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAMbEA3/CJL Engineering PHONE 860-257-3968 ❑ STORAGE ❑GARAGE ADDRESS 203 Ariarwood Ct. Rocky Hill CT. 06067 ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SEU Cable SIZE OF SERVICE 4 0 0 amp X I SIZE OF MAIN CONDUCTORS_ 4/0 Al NUMBER OF METERS 21 NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS 21 REMOTE DISCONNECT REQUIRED? U YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Install three meter banks, two groups of six and one group of nine the last containing the owners meter. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 123580 E-1 CT. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is ereby: TOWN OF SOUTH WINDSOR �� I BUILDING DEPARTMENT PR 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date ul ding Inspector Application must be printed or typed Location of Job: FEE SCHEDULE 14 Berry Pates 2R $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 14 or any fraction thereof Tenant Designation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# (860) 623-1991 OWNER Berry Patch Associates Limited Partnership W 3�q� OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, CT 06032 OWNER PHONE (860) 674-5641 C ESTIMATED COST$ 6, O O U� .� a. IS THIS A CONTRACT COST? X Yes _No FEE ENCLOSED$ y 4,A TYPE OF JOB: SOR.CO X New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 2J HEATING ❑RESIDENTIAL 25 A/C ❑ COMMERCIAL 21 VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LD41T LBS. ❑HYDRONIC IN WARM AIR ❑UNIT RADIANT HEATER PER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION PLANS DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF & TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY SPECS APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Magic Pak M/N 51 HWC 2431-2B GROSS HEATING CAPACITY(INPUT BTUH)51,000 NET RATING(OUTPUT—BTUH) 41,000 TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑ INSIDE❑ OUTSIDE CAPACITY 3 GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING PER DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE °F PLANS TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) & DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) SPECS TONNAGE 2 COOLING CAPACITY(BTUH)24,000 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CM (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK 303755 S-1 CP CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT / DATE Electric # I-657S-1 11SloSli APPLICATION FOR BUILDING PERMIT Plumbing# 113(oq 14 Winterberry Lane (Building 2) Date: HVAC # I t S161 ��- Sprinkler# 1 29995 FINAL APPROVALS Estimated Cost $ 38,000.00 Building Permit Fee $ COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $ A r. for CO. SIGN ON REVERSE SIDE Affidavit pp Total Fee $ TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant The Metro CorL nirtican cj0 r. Location of Work 14 Berry Patch Winterberry Lane Lot No. 2R Applicant's Address 6 Executive Drive Tel. # 860-674-5640 Town FanningtM, CT Zip 06032 Lic. #MM 90n4u Owner- Berry Patch Associates L_P_ Architect Assrri atexi Arrhi tPc-tc Owner's Address 6 Exemitive Drive Architect's Address lb spri nnq Tana Farmington, CT Zip 06032 Farmington, Cr Zip 06032 Sq. Ft. New Area: 1 st FI. 896 s.f. 2nd FI. ---- 3rd FI.---- Total New Area 896 s.f. Purpose of this permit conctruct.i-0n_ multiple rl a single fermi l y affor able dwell}ng City Watery Well❑ Septic System❑ Sewer[k Ins: HO Area Basement Garage Approved by r . ate Use Group Construction Type R"sed W02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building be k)cat the proper distance from all street lines,side yard lines,and required distances from all other zones and is k)catecin h this u ing and its use is allowed. Signed I hereby apply for a Certificate of O upanc ,fo the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-29995-B 22,000 BO1 FOOTING 10/02/03 WNB A B02 FOUNDATION 10/10/03 WNB A P03 ROUGH 04/28/04 PJP A PO4 GAS TEST 03/30/04 JFF A E03 ROUGH 04/30/04 PJP D PHONE/EDDY SECURE ROMEX, SECURE GAS LINES, #1 #16 NAILPLATE GAS LINE, DRAFTSTOP INT CORNER S03 ROUGH 04/30/04 PJP NO TEST B04 INSULATION 05/21/04 PJP A W/EDDY LOWER LEVEL ONLY B04 INSULATION 05/11/04 JFF A CALLED ED ON CEILING TO BLOW IN REMAINDER OF INSULATION B10 FINAL 11/10/04 PJP A B10 FINAL 11/19/04 PJP A CLOSEOUT **-1266-S 1,000 **-11881-H 6,000 **-11369-P 5,000 **-18575-E 2,945 **-18659-E 10,000