HomeMy WebLinkAbout1364 ELLINGTON RD DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Lplication i by:
BUILDING DEPARTMENT / 2 ��
1540 SULLIVAN AVENUE Bldg.Permit#
)(J 644-2511 ext. 230
GULZilding Inspec
Application must be printed or typed
FEE SCHEDULE Location of Job:
/3
$0-$1,000=$15.00 Street No. treet Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT fl/-7*1 �G i✓'yv,ai,�,
APPLICANT ADDRESS
5 o,o4A k/,'., d s a r c - o f 0 7 y
APPLICANT PHONE# L/ 3 of - /&-7 3
OW N S j , OWNER SI`9 M E:
aOWNER ADDRESS
OWNER PHONE
C ESTIMATED COST$ 3 5-p C-�- "
•�, IS THIS A CONTRACT COST? _Yes T10
A&P G FEE ENCLOSED$
SO. Co TYPE OF JOB:
R New Installation
_Alteration/Addition/Repair
Revised ainiinnm
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
❑HEATING ❑RESIDENTIAL
w</C ❑COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC ❑WARM AIR ❑ UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS (BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
❑OIL—GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY
❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
y� DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
G cr^ -<la Ae kG 1 c-4 Cro.l d o'h s -e---c?/9 -7i9 /y a`j— car]c:l
TONNAGE COOLING CAPACITY(BTUH) z;2 elJ 000
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENS TYPE STATE
SIGNATURE OF APPLIC CDATE
J
If
RIGHT-J SHORT FORM ,0
Entire House
Project Information
FA,L 1Z1►+�9/J
For: 1364 ellington rd
Design Information
Htg Clg Infiltration
Outside db(°F) 8 88 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD(°F) 62 13 Fireplaces 0
Daily range - M
Inside humidity(%) - 50
Moisture difference(gr/Ib) - 22
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Efficiency 80.0 AFUE Efficiency 0.0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temperature rise 0 OF Total cooling 0 Btuh
Actual heating fan 1031 cfm Actual cooling fan 1031 cfm
Heating air flow factor 0.020 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh
Space thermostat Load sensible heat ratio 89 %
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
living 209 13255 5104 265 273
bed 99 5374 1771 107 95
bed 2 126 7533 2304 151 123
master 154 8228 2655 165 142
bath 32 2223 554 44 30
bath 2 40 2337 571 47 31
kitchen 165 7490 5091 150 272
din 110 5141 1234 103 66
Entire House d 935 51581 19285 1031 1031
Ventilation air 0 0
Equip. @ 0.93 RSM 17935
Latent cooling 2320
TOTALS 935 51581 20255 1031 1031
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
,A wnghttsofll: RightSulte Residential-5.0.66 RSR27744 -05 14:29:38
ACCA PrD)wl.rsr 2005 May
. . _ :iv _ .. ,._