Loading...
HomeMy WebLinkAbout1364 ELLINGTON RD DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Lplication i by: BUILDING DEPARTMENT / 2 �� 1540 SULLIVAN AVENUE Bldg.Permit# )(J 644-2511 ext. 230 GULZilding Inspec Application must be printed or typed FEE SCHEDULE Location of Job: /3 $0-$1,000=$15.00 Street No. treet Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT fl/-7*1 �G i✓'yv,ai,�, APPLICANT ADDRESS 5 o,o4A k/,'., d s a r c - o f 0 7 y APPLICANT PHONE# L/ 3 of - /&-7 3 OW N S j , OWNER SI`9 M E: aOWNER ADDRESS OWNER PHONE C ESTIMATED COST$ 3 5-p C-�- " •�, IS THIS A CONTRACT COST? _Yes T10 A&P G FEE ENCLOSED$ SO. Co TYPE OF JOB: R New Installation _Alteration/Addition/Repair Revised ainiinnm APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATING ❑RESIDENTIAL w</C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY ❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) y� DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) G cr^ -<la Ae kG 1 c-4 Cro.l d o'h s -e---c?/9 -7i9 /y a`j— car]c:l TONNAGE COOLING CAPACITY(BTUH) z;2 elJ 000 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENS TYPE STATE SIGNATURE OF APPLIC CDATE J If RIGHT-J SHORT FORM ,0 Entire House Project Information FA,L 1Z1►+�9/J For: 1364 ellington rd Design Information Htg Clg Infiltration Outside db(°F) 8 88 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 62 13 Fireplaces 0 Daily range - M Inside humidity(%) - 50 Moisture difference(gr/Ib) - 22 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Efficiency 80.0 AFUE Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 1031 cfm Actual cooling fan 1031 cfm Heating air flow factor 0.020 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 89 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) living 209 13255 5104 265 273 bed 99 5374 1771 107 95 bed 2 126 7533 2304 151 123 master 154 8228 2655 165 142 bath 32 2223 554 44 30 bath 2 40 2337 571 47 31 kitchen 165 7490 5091 150 272 din 110 5141 1234 103 66 Entire House d 935 51581 19285 1031 1031 Ventilation air 0 0 Equip. @ 0.93 RSM 17935 Latent cooling 2320 TOTALS 935 51581 20255 1031 1031 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ,A wnghttsofll: RightSulte Residential-5.0.66 RSR27744 -05 14:29:38 ACCA PrD)wl.rsr 2005 May . . _ :iv _ .. ,._