Loading...
HomeMy WebLinkAbout131 PEPIN PL BLDG 18 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PER1vff# Application' y: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT J S6 U G PRO 1540 SULLIVAN AVENUE Bldg.Pennit 644-2511 EXT.230 (Date) kNilding Inspector) Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000- $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT `JaN rp izy C (mow/G 2, APPLICANT ADDRESS /l Qom./� .►y �iac t (7a, 4,0•3-J- APPLICANT PHONE# S O W N S F,q OWNER r g m 6,., ec, Cell OWNER ADDRESS r j p ADD S f OWNER PHONE OESTIMATED COST $ IS THIS A CONTRACT COST? YES NO � o FEE ENCLOSED$ � 1��5 O�� TYPE OF JOB: I Oct �R C New Installation _Alteration/Addition Repair 2b c5; Revised 12=1I APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OFBUQ.DING IS THIS APPLICATION ASSOCIATED WITH A X'kESIDENTIAL BUILDING PERMIT APPLICATION? e YES ❑ NO O BUSINESS CURRENT USE AND OCCUPANCY O ASSEMBLY O MERCANTILE C3 EDUCATIONAL FUTURE USE AND OCCUPANCY O FACTORY O STORAGE ENGINEER'S NAME PHONE O GARAGE O MIXED USE ADDRESS (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION N�P� 12 j J(4u SIZE OF MAIN DRAIN NO. OF TOILETS _STYLE U D; n,,.i t' NO.URINALS STYLE NO. OF BATHTUBS�_ NO. OF SHOWERS Z NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO. OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW O YES O NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN f h SIZE OF WATER PIPING&RISER YY v 4, WATER HEATER: TYPE e (.e C n, 1 c- MANUFACTURER Lo -5, rr t DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 9 �� 1 APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT p a y I H APPR 1540 SULLIVAN AVENUE Bldg:Permit# 644-25•11.ext. 230 15062�a Date Building Inspec (r Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$1s.00 / 3/ � �:fA Over$1,000= Street No. Street Lot No. $15.00.per$1,000 or any fraction thereof Tenant Designation Apt No. APPLICANT R ybe•+ C) APPLICANT ADDRESS Z2 En Fle woe j p CT O(,*oU Z, APPLICANT'S PHONE# 96 y' ,,0* N SF�9 OWNER T9- W7 S&� � -,ef OWNER ADDRESS _f/d Ro&K S oG I go O F OWNER PHONE lD �,/ .-�'a?�, 91 C ESTIMATED COST$ ,-5--appy U IS THIS A CONTRACT COST? Yes No FEE ENCLOSED-$. �75 .mQ o o TYPE OF JOB: __#/d SOR•CD New Installation Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE of BUrLDIN IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES O NO RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑. ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE, ❑ FACTORY U. STORAGE ADDRESS ❑ GARAGE . i] MIXED USE CITY STATE ZIP (Other plm"Ispecify) TYPE OF INSTALLATION/WIRING METHOD.. SIZE OF SERVICE 900/� . SIZE OF MAIN CONDUCTORS NUMBERS OF METERS NUMBERS.OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ ,YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF.HEAT CIRCUITS NUMBER'OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEARBYAPPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OFAPPLICANT_ lam, DATEiS— Revised 4/01//2002 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: 150 bLj(t BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspect Application must be printed or typed FEE SCHEDULE Location of Job: F $0-$1,000=$15.00 Street Lot No.Over$1,000 /$15.00 per$1,000 �"or any fraction thereof gnation Apt. No. APPLICANT ALL A APPLICANT ADDRESS AIR CONDITIONING, INC. 770 Boundline Road APPLICANT PHONE# (203) 879-4928 O W N S OWNER -g p� OWNER ADDRESS ID -Tart'na7* C7 OWNER PHONE 64) 7 ESTIMATED COST$ 7,.5M IS THIS A CONTRACT COST? _Yes _No FEE ENCLOSED$ 6�D,OV 1�OS TYPE OF JOB: -# 41,7 R C New Installation Alteration/Addition/Repair v - a APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: E G RESIDENTIAL B1 0 6 ❑COMMERCIAL ❑VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 44 d►tea 'ail: L�2ry f3 L, c0'It, �i i% C"Id gmk4 GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL 0 OIL-GPM OIL TANK LOCATION :❑ INSIDE❑OUTSIDE CAPACITY LLgAlS=INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) I CV-V7 4 eVs',U4 6114. G 5x/so/,e// �� fw TONNAGE S COOLING CAPACITY CBTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLIJ II , KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIRAKE jCFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. _ Ds 9l � s/ C CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT /� DATE 9-Z j zo�S wri htsoft- Project Summary Job: 9 Date: September ,2015 Entire House By: Jon Valrmont All American Heating &Air Conditioning Inc. 770 Boundline Rd.Woks CT06716 Phone:203-879.4928 Fax 4920 Email:missducMarkeaol.com License:0391792 MOIR a 1111 • • For. Unit 124 131 Pepin Place, T&M Homes South Windsor, CT 06074 Notes: Design Information Weather. Waterbury, CT, US Winter Design Conditions Summer Design Conditions Outside db 2 OF Outside db 85 OF Inside db 70 OF Inside db 75 OF Design TD 68 OF Design TD 10 OF Daily range M Relative humidity 50 % Moisture difference 29 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23616 Btuh Structure 9649 Btuh Ducts 4742 Btuh Ducts 2848 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28359 Btuh Use manufacturer's data n Infiltration Equip ent sensible load 1 247 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1082 Btuh Ducts 543 Btuh Heatingg Coolingg Central vent(0 cfm) 0 Btuh Area(ft� 1072 1072 Equipment latent load 1625 Btuh Volume(ft� 10409 10409 Air changes/hour 0.57 0.23 Equipment total load 12873 Btuh Equiv.AVF(cfm) 98 40 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 556 cfm Actual air flow 556 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2015-Sep-23 07:34:10 4Z wrightsofV Right-SUlte®Universa1201515.0.16 RSU17966 Pagel /5& ...-1—lDeskbp\Wright90n P-Jeds\1.5 Tonlup Cal -MA Front Door faces:W Electric # APPLICATION FOR BUILDING PERMIT Plumbing# HVAC# 1221 P����e Date: ZJ/S� Sprinkler# 150D FINAL APPROVALS Estimated Cost $ ov Permit Fee $ Building COMPLETE RED BOXED AREAS Engineering Occupancy Fee $ 10 ' Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee $ Appr.forCO. 00- SIGN ON REVERSE SIDE t Total Fee $ (Ua U TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ \k7_4 The undersigned hereby applies to do work according to the following: Applicant__% M /L /_ Od. Location of Work.�_'�/ fP�� _G�9 -_ Lot No. Applicant's Address _l10 �'OD.t' S% - Tel # a6� �/�Cl-9 a Z 9 Town 77 RA,,VG=7RT.) ''zip 0679U _Lic.# 1611 _ Owner Architect /�IfNS ✓ Owner's Address Architect's Address /SZ SA ` 4r 66U Sq. Ft. New Area: 1st Fl. y9 2nd FI. 3rd FI. Total New Area «2� Purpose of this permit &W 57P-U e-r 5--1AU A it //L A,4T#5 10 rV 7Ma4i-k"� a 447e At�Ee4 - -- ( 195HF04� >'►'tOt�FL} City Water Well J Septic System J SewerA '101 S CspS, Ins: HO SP Cert. ✓ Area Basement Garage Approved by Date L-f! -/ Use Group T41­C— Construction Type ^ Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to b located the proper distance fr all street lines,side yard lines,and required distances from all other zones and is located in w ich this building d its use allowed. Signed I hereby apply for a Certificate of jDccancy for the work descri d in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS INSPECTION FIELD SHEET 04/19/22 Printed by Middleton, Morgan 15 22 10 INSPECTION: 86240 FINAL PERMIT: STATUS: APPLICATION: 201500557 LOC: 131 PEPIN PLACE SOUTH WINDSOR PROPERTY ID: 70700131 OWNER: T & M BUILDING CO INC CONTRACTOR: T & M BUILDING CO. , INC. 860-883-5910 REQUEST BY: PROJ DESC: CONSTRUCT SINGLE GAMILY TOWNHOUSE, 2 BEDROOMS, 2 1/2 BATH, WORK ORDER: INSPECTOR: DOUG RESULT: PASS REQUESTED: PRIORITY: SCHEDULED: COMPLETED: 06/10/16 UNPAID FEES: .00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS: ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 05/16/16 DOUG N/A B001 FOOTING 07/06/15 ROSE PASS B002 FOUNDATION SLAB POLY/PERIMETER INSULATON 11/06/15 DOUG PASS B003 FRAMING (ROUGH) BOB 0 860-250-6144 11/10/15 DOUG PASS B004 INSULATION BOB ® 860-250-6144 05/16/16 ROSE N/A B005 FIREPLACE / CHIMNEY 05/18/16 DOUG PENDING BO10 FINAL BOB ® 860-250-6144 FIRE PROOF STAIRS, DECK STEP 12/31/15 ROSE PENDING E001 ELECTRIC SERVICE incomplete bonding of electrical system O1/20/16 ROSE PENDING E001 ELECTRIC SERVICE CONTR. PROPOSE TO CONSULT ENG. RE: INSTALLATION 02/09/16 ROSE PASS E001 ELECTRIC SERVICE OK TO RELEASE TO EVERSOURCE REVIEW WITH C.B.O PROF. ENG SUBMITTAL FOR BLDGS. #2 AND 18 AS SHOWN ON EMAIL OF 2/2/16 11/02/15 ROSE PASS E002 ELECTRIC UNDERGROUND THREE CONDUITS 11/06/15 DOUG PASS E003 ELECTRIC ROUGH INSPECTION FIELD SHEET 04/19/22 Printed by Middleton, Morgan 15 22 10 11/06/15 DOUG PASS H003 HVAC ROUGH 05/16/16 ROSE N/A P002 PLUMBING UNDERGROUND 10/27/15 ROSE PASS P003 PLUMBING ROUGH JAN ®-841-8738PRESS. TEST ON DWV &WATER PIPE RISER /BRANCH 10/27/15 ROSE PASS P004 PLUMBING GAS TEST PRESS. TEST ON GAS PIPE/METER SERVICE 06/08/16 FOLG PASS Z003 CO PLANNING INSPECTION ALL AMERICAN HEATING ♦ AIR CONDITIONING, INC. P.O. Box 6397 Wolcott, Connecticut 06716 Phone: (203) 879-4928 Fax:.(203) 879-4920 CT License#303291 CT License#391792 CT License#203918 Date 1, Jay C Valimont Sr, hereby grant permission to ` to apply for a HVAC permit in the town/city of � using my S1-0391792 license for the address Sincerely, t ' � 6 IIEATING,KPING&C00UNG UNLIMITED CoNrIIAC'ron JAY C VALIMONT SR PO BOX 6397 J alimont Sr I W01,COTT,C'T 06716-0397 I President LIC./REG N (203)879-4928 IITG.0391792-S1 09/01/2015 03/31/2016 SIGNED Vd�0 _ _