Loading...
HomeMy WebLinkAbout13 RYE ST x0 7;j APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SQUT�I WIND OR ~ ~# Application is hereby: t 0 BUILDINGDE]ARWENT N — APP OV s r 1540 SULUVAN A�NUE n = 1' r: 'r y Bldg. Permit# —_ 644-2511 ext. 230 Date Building Inspec�tor Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 fi v c' :�A ­(-<--� Over$1,000= Street No. f Street Lot No. $15.00 per$1,000 9 ,e S - Fa or any fraction thereof Tenant Designation Apt. No. APPLICANT V1I tu,t APPLICANT ADDRESS A D APPLICANT'S PHONE# OWNER S-Fe Ua- OWN Sf q q� OWNER ADDRESS yb_j U ed 1 OWNER PHONE ESTIMATED COST$ 3 7 w C � U IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ TYPE OF JOB: { 11 yl� �SpR.CO� _:�New Installation Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT(C egQkUwerse. ide) QF BUILDING IS?THI APPLICATION ASS BML.I)IN PERMIT APPLICAT imp- TYXE ❑ O IAESID NTIAL N ,� CURRI AT�J$ OCIUPANCY ELBUSINESS r - ❑:ASSEMBLY FUT UI 1 A }'p CC4.ANCY o t U-EDUCATIONAL -_ " . � LFINSTITUTIONA_L ENGINEETS N�4 I ❑ FACTORY ❑ STORAGE ADDRESS i -❑ GARAGE - ❑ MIXED USE CITY STATE ZIP (Other please specify) JYPE OF INSTALLATION!WIRIN r r , tr I a- 3 j I y � 1 71 t SIZE OF SERVICE `; a SIZ Oih'1VIA�N COftUCTORS "; HNt'RvIBERS OF METERS N BERS OF DI C6NN' AND RATINGS i�T c s�NUMBERS OF PANELS .o NU BE (a DISC NNI A REQUIRED? 43 WS u=1v0 m ` C O v O NUMBERS OF LIGHT CIRCUITS BER bi5POm CIR UITS `-' NUMBER OF SWITCHES BER pF UT LETiS °c ` o NUMBER OF LIGHT FIXTURES BER b1 F I EA r CI RCIT I NUMBER OF AIC CIRCUITS 5' SEPARATE HEAT LOSS AND A/C CAUCULATIO MU�T I1E B ' TE DESC PTICIN C�F 701RK o 'er, ii-z�l AcJ a G L2 U C - - AcceS nfr 7 t I I THE UNDERSIGNED NEARBY APPLIES FOR.AI E T To PE RF T�WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES A" TA E 04 CON ICUT�UILDING'CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. i1 TYPE STATE a SIGNATURE OF APPLICANT w� 1.�-'�-- DATE to l o w 0 N O DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: UOopoO� BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# I.I ILinspm Ar 644-2511 ext. 230 goo32a ate Build Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Stre�;No. � Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenantion Apt.No. ol APPLICANT t✓ ��1's/ I I APPLICANT ADDRESS /t' /'c O OF P-T -AG ICSa IV W /¢ - APPLICANT PHONE# Ly cN K O 4 N S F,q OWNER OWNER ADDRESS CIO) OWNER PHONE 0 . /� C ESTIMATED COST$ 1;y. IS THIS A CONTRACT COST? _Yes _No FEE ENCLOSED$ 7 9 5 O�� TYPE OF JOB: #F4/75U R-C New Installation Alteration/Addition/Repair Revised 4/01//2002 • APPLICATION FOR SPRINKLER PERMIT (Continued from reverse side) TYPE OF BUILDING TYPE OF CONSTRUCTION USE GROUP NO. OF STORIES ❑RESIDENTIAL ❑BUSINESS IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑MERCANTILE ❑EDUCATIONAL CURRENT USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ❑STORAGE ❑GARAGE ENGINEER'S NAME PHONE ❑MDCED USE (Other please specify) ADDRESS CITY STATE ZIP KIND OF INSTALLATION SIZE OF MAIN DRAIN WATER PRESSURE AT STREET(PSI) ARE SPRINKLER HEADS ALTERED? ❑YES ❑NO IF YES,CHECK ALL THAT APPLY: ❑ADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) ❑PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES ❑NO IF YES,CHECK ALL THAT APPLY: ❑FIRE ❑BOOSTER ❑OTHER ARE STANDPIPES PROVIDED? ❑YES ❑NO IS A SPRINKLER SYSTEM PROVIDED? ❑YES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP PSI DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE / � ALLSTATE FIRE EQUIPMENT •. New England's leader in Fire Protection 15 ROBERT JACKSON WAY 45 PLAINVILLE, CT 06062 6 OFFICE(860)793-6900 aS FAX(860)793-6906 www.al Istatefire.biz Public Act No. 91-95:An act concerning the requirement that licensed contractors as defined in Section 20-330 of the General Statutes must personally sign each building permit application. Date: /f ATTN: Building Official RE: rir< To Whom It May Concern, In Accordance with Public Act 91-95, this letter Authorizes the below named agent to sign the above reference permit application. 1. Project Name: C1 Kee 3. Starting Date: 4. Licensed Contractor's Name: Michael Gagnier 5. Licensed Contractor's Trade License No.: FRP.0030042-F3 6. Name of Agent: Sincerely. 1 1 FIRE PROTECTIOIN UIIViIT D CONTRACTOR MICHAEL J GAGNIER Signature of Lice ontractor 33 MACINTOSH WAY S0UTHINGT6?ft°:- 06489-2053 LIC./AEG NO. EFFECTIVE; EXPIRES FRP.0030042-F3 ll/01/2010 Ag 10/31/2011 SIGNED I - 1_Application_For Permit l � IMAM CT LIc. #F30042 • MA-CR. 1097 J 1 ALLSTATE FIRE EQUIPMENT • New England's Leader in Fire Protection 15 ROBERT JACKSON WAY 45 PLAINVILLE,CT 06062 6 OFFICE(860)793-6900.E FAx(860)793-6906 www.allstatefire.biz Fixed Automatic Fire Suppression System Proposal # 10221ODB01 October 22,2010 Issued to: For location if different Raymond Favreau South Windsor Parks and Recreation South Windsor,CT Via email:Raymond.Favreau@southwindsor.org southwindsor.org This proposal is for a new automatic fire suppression s tem(s). Hood ducts,plenum and cooking appliances to be protected are as follows: 9'hood over a fryer,a 24"4-burner range and a 4'griddle Standard System Specification-Includes all necessary agent cylinders,mounting hardware,controls,fusible link detection line,(1)SURFACE MOUNTED ONLY pull station,all system piping and nozzles with UL listed seals at exterior hood penetrations,up to(3)microswitches for use by the electrical/fire alarm trades,a mechanical gas valve up to 2"in size for installation by the plumbing trade,diagrams,local permit and(1)test for the Fire Marshal. All labor at open shop wage rates during normal working hours,M-F,8pm-4pm. 1%fodifications that change the Standard System Specification must be included in the box below to be in force for this proposal. Gas Plumbing Exclusion -All State does not perform any gas piping work and it is the customer's responsibility to hire a licensed plumber to install a new gas valve prior to the scheduled date of fire system installation. Electrical Work Exclusion-Electrician's fees and additional equipment needed beyond the microswitches to transfer or tie in alarm and electric shut-downs as may be required is not included in this proposal System Retesting-We include one acceptance test for the fire marshal,which must be scheduled by the customer for a specific time and day,and for which we must receive at least 72 hours notice. Systems that fail due togas plumbing or electrical requirement deficiencies(outside the scope of our work),or scheduled appointments that fall through or are not cancelled at least 24 hours prior to the scheduled time,such that another site visit for retesting is required,will result in additional charges above the amount of this proposal. Per the above,we will furnish and install an Ansul R-102-3 gal.U1-300 fire system for a cost of S 2,250.00 plus any applicable sales tax. PAYMENT TERMS-Net 30 on town issued P.O. WARRANTY-One year on parts and labor. VALIDITY-This proposal only valid for 90 days from date of issue.COLLECTIONS-All materials remain the property of All State Fire until paid in full and the customer acknowledges responsibility for late payment fees and costs associated with collection activities including but not limited to:in-house administrative costs,fees and percentages charged by third party collection agencies and court and attorney costs. Late payment fees accrue at a rate of 0.0005%per day. Proposal prepared by Dick Boland on behalf of All State Fire,October 22,2010 ACCEPTANCE-By signing below,customer acknowledges acceptance of this proposal and hereby authorizes the work described to be performed by All State Fire Equipment under the given terms and conditions. Customer Printed Name Title Signature Date I Page 1 of I i1. Ai1tSlJL.I Install Date: 2011 All State Fire Equipment, Inc. South Windsor Parks and Recreation 71 Church Ave. Rye St Bristol, CT 06010 South Windsor, CT 06000 Mike Gagnier r Ray 860-585-8885 info@allstatefire.biz F3-30042 South Windsor Parks and Recreation System a 0 o� O � Manual Pull with wire rope x1 3.0 Tank & Reg. Release page 1 of 5 "I APJSUL. Install Date: 2011 All State Fire Equipment, Inc. South Windsor Parks and Recreation 71 Church Ave. Rye St Bristol, CT 06010 South Windsor, CT 06000 Mike Gagnier Ray 860-585-8885 info@ allstatefire.biz F3-30042 South Windsor Parks and Recreation System South Windsor Parks and Recreation Layout Duct 20 x 14 in. 108x20in 1 Gndde paten ]� 48 x 24 in, Range gratirgs 24 x 24 in. 1 Fry vat,14 x 16 in. With dripboard:14 x 21 n Flow Summary: Coverage I Overall Dimensions I Nozzle Flows Nozzle Location Hood:Single Bank 108 x 48 in. 1 N 1 0-4 in.from filter face,center of height dimension,aimed down fitter length. Duct:Square 20 x 14 in. 2W 2 2-8 in.into center of dud opening,aimed up Fryer.1 vat,dripboard 16 x 30 in. 3N 3 25-35 in.,FRONT HALF of perimeter,aimed at center Range:4 burners 28 x 30 in. IN x2 2 D-20 in.,above short side of hazard area or module,aimed at centerline,20 in See Note 1 Griddle 52 x 30 in. 260 2 3D-50 in.,0-2 in.inside perimeter,aimed at center Total Flow Points 10 page 2 of 5 1:1.1ANSUL.1Install Date: 2011 All State Fire Equipment, Inc. South Windsor Parks and Recreation 71 Church Ave. Rye St Bristol, CT 06010 South Windsor, CT 06000 Mike Gagnier Ray 860-585-8885 info@allstatefire.biz F3-30042 Notes Project Notes: Automatic fire suppression system plans and specifications in compliance with; UL 300, NFPA-17A (2002), 2003 IFC-904.11, 2003 IBC-904.11, 2003 IMC-509.1 Microswitches are provided for electrician to make applicable connection (including make-up air fan shut-down, electric appliance shut-down, & alarm tie-in). All Hood penetrations will have UL-listed (UL# 21_09) grease seals. Manual Pull Station to be located in the path of egress 48" above finished floor. All fuel sources (natural gas, LP, or electric) will shut-down upon system activation. System will be installed into a new exhaust hood. Fusible Links: => To determine actual fusible link ratings, temperature readings must be taken during peak cooking time. South Windsor Parks and Recreation Layout: Note 1 => Nozzle: 1 N x2: (Range:4 burners) nozzle position: 0-20 in., above short side of hazard area or module, aimed at centerline, 20 in. from edge below nozzle. page 3 of 5 APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is BUILDING DEPARTMENT 1 DU 1 Ofo APP OV D 1540 SULLIVAN AVENUE Bldg. Permit# q, �� C,::�4--.. 644-2511 ext. 230 Date ding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 ���e S Over$1,000= Street No. Street Lot No. $15.00 per$1,000 9� or any fraction thereof Tenant Designation Apt.No. APPLICANT ( i 0, _ APPLICANT ADDRESS U S' R tN el APPLICANT'S PHONE# OWNER g 0 W N S Fq OWNER ADDRESS OWNER PHONE O = ESTIMATED COST$ C IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ 1 , 30 L) TYPE OF JOB: - 1 'USO .Co kr New Installation 3 R �5 Alteration/Addition/Repair Revised 03/05/10 J APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑ HEATING ❑ RESIDENTIAL ❑ A/C ❑ COMMERCIAL 4 VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK >,A THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRA TORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 3 EXHAUST FAN TO EXHAUST FAN TO BE CZP"C GASMrr HINGE OPEN FOR LOCATED 10' FROM AIR GENERAL NOTES CLEANING AND ^---. INTAKES,DOORS AND WINDOWS. CONICAL SPRING INSPECTION r �'- FMn xASBaR TYPE 1 HOOD TO OVERHANG COOKING EQUIPMENT BY MIN OF 6" ON ALL SIDES.{COOKING EQUIPMENT BY co f TING OTHERS AND NOT TO EXCEED 8' IN TOTAL LENGTH) Do CLEANABLE GREASE UTSR DOOR DUCT*"u TYPE 1 EXHAUST DUCTWORK TO BE CONSTRUCTED OF 16 GAUGE STEEL, WELDED LIQUID TIGHT. 40 HIGH TEMP ACCESS DOORS TO BE INSTALLED AT CHANGE OF DIRECTION IN EXHAUST DUCTWORK 00 r- SUPPLY AIR IS TO BE INTRODUCED THROUGH THE 2-5' PASS THROUGH WINDOWS. DO GENERIC DRAWING WINDOWS NEED TO BE OPEN TO OPERATE THE STAND. ROOF MAY BE 18 INSTALLATION OF HOOD AND DUCTWORK TO MEET I.M.C. 2003 STANDARDS o PITCHED. ALL DIM. ARE FROM THE CURB FIDE DOOR BOLT 1lYIDSD TO LHHYR DOOR ELECTRICAL CONNECTIONS BY OTHERS. U >`� OF THE WRB OR FAN GA BACK PIAM FIRE SUPPRESSION SYSTEM BY OTHERS. X ¢ 0 � EXHAUST DUCTWORK TO BE LL- :3 INSULATED WITH UNIFRAX DUCTMATE HIGH TEMP ACCESS DOOR I @� 2-1 ULTRA GREASE DUCT WRAP F-W WHERE 18" TO COMBUSTIBLES o J z Z CAN NOT BE OBTAINED. = Q Z DUCT TO HOOD I (n O d 0 ROOF PENETRATION O= NI,- CO DO 00 Li z O o_ o � EF EF P- OO co U� 12 14 14/1 W W E- ■ 10' TYPE 1 HOOD 0 m W SERVICE WINDOW W WALL CONSTRUCTED OF I" METAL,-_ STAINLESS FEEL WALI PANELS :vl CHANNELS AND 5/8" SHEETROCK 616. 24" 16" 16" Q. STOVE FRYEF FRYER GRIDDLE 0 Z Q F- F- (n v Y z Q� O D 0 (n V �� LEI � O U I- Z V _ O '0 U Ir U) W Ld ~ O F- SCALE None DRAWN BY PPS DATE 02 24 it REVISIONS Dwg. N0. N—1 HOOD INFORMATION SPECIFICATIONS: SND-2 MODEL EXHAUST PLENUM SUPPLY PLENUM HOOD CONFIG. SWITCHES unnn MAX I TOTAT. I RTRV.R TAT AT. RTSFR unnn 11VVL MODEL LENGTH COOKING j"'"""' ".--- "" """ —0— END TO THE MODEL SND IS AN EXHAUST CANOPY HOOD WITH A SLOPED NO. EXH. ySUP. CONSTRUCTION ROW QUANTITY LOCATION TEMP. CFM WIDTH LENG. DIA. CFM S.P. CFM WIDTH LENG. DIA. CFM S.P. END FRONT WHICH IS UL LISTED AS EXHAUST HOOD WITHOUT DAMPER 4812 9' 0.00" 600 10" 24" 2655 —0.609" 430 SS 1 FAN FRONT (FILE MH12106).RIGHT THE HOOD COMPONENTS SHALL BE FABRICATED OF TYPE 430 1 SND-2 Deg 2655 O where Exposed ALONE ALONE 1 LIGHT FACE STAINLESS STEEL, #3 OR #4 POLISH, ON ALL EXPOSED_ SURFACES. RFACES. CONSTRUCTION SHALL BE IN ACCORDANCE WITH NFPA 96. THE HOOD SHALL BE PROVIDED WITH HANGING ANGLES ON EACH END OF THE HOOD. AN ADDITIONAL SET OF HANGING ANGLES HOOD INFORMATION WILL BE PROVIDED FOR HOODS GREATER THAN 12' IN LENGTH. FILTERS LIGHTS UTILITY CABINET(S) L+rn� unnn 1'11YL' 11V VL HOOD WIRE FIRE SYSTEM ELECTRICAL SWITCHES SYSTEM ANGIN THE HOOD SHALL BE FITTED WITH U.L. 1046 STAINLESS STEEL NO. TYPE QTY. HEIGHT LENGTH QTY. TYPE GUAR LOCATION TYPE SIZE MODEL # QUANTITY LOCATION PIPING WGHT BAFFLE FILTERS WHICH ARE EASILY REMOVABLE FOR CLEANING. THE FILTERS WILL DRAIN THE GREASE INTO A SLOPED GREASE 310 DRAIN SYSTEM WITH REMOVABLE 1 2 PINT CUP FOR EASY CLEANING. 1 SS Baffle with Handles 3 16" 20 3 Incandescent Light Fixt NO NO LBS HOOD LIGHTS SHALL BE U.L. LISTED SUITABLE FOR GREASE HOODS AND SHALL BE SUPPLIED WITH PLASTIC COATED GLOBES. EACH LIGHT WILL ACCOMMODATE UP TO A STANDARD 100 WATT BULB. ALL LIGHTS WILL BE PRE-WIRED TO JUNCTION BOXES ON TOP OF THE HOOD. A HOOD DIMENSIONS SHALL BE AS SHOWN ON DRAWINGS. 48" INCANDESCENT LIGHT FIXTURE-HIGH TEMP FIELD CUT EXHAUST RISER ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (1,55 FIXTURE) HANGING ANGLE 18" SS BAFFLE WITH HANDLES AND HOOK 3" INTERNAL STANDOFF D Field Cut 10" X 24" IT IS THE RESPONSIBILITY L _ _ _ _ J Exhaust OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE Riser FROM LIMITED-COMBUSTIBLE /27" MIN. --I AND COMBUSTIBLE MATERIALS U.L. Listed Incandescent Light IS IN COMPLIANCE WITH 48.0" MAX 48" g LOCAL CODE REQUIREMENTS. Fixture—High Temp Assembly " GREASE DRAIN 92 WITH REMOVABLE CUP 80" AFF TYP. EQUIPMENT BY OTHERS FAN & LIGHT SWITCH 9' 0.00"Nom./9' 0.00"OD SECTION VIEW - MODEL 4812SATD-2 EXHAUST CFM=LENGTH OF HOOD X CFM/UN.Fr. (LOAD) PLAN VIEW — Hood # 1 SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED TOTAL DUCT AREA=144 X CFM 9 ' 0 .00 LONG 4812SND - 2 FMP(s) TOTAL DUCT AREA DUCT LENGTH= DUCT DEPTH PLEASE NOTE: THE HOOD MAY BE INSTALLED *CAPTIVE-AIRS VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST WITH A 0 INCH CLEARANCE TO COMBUSTIBLE VELOCIT MAXIMUM OG 1600-1800 FPM AND A SUPPLY VELOCITY OF 1000 FMP. MATERIALS IF CONSTRUCTED IN ONE OF THE PLEASE CONSULT FACTORY FOR ALLOWABLE DUCT SIZES FOLLOWING METHODS: CH LAYER OF INSULATION (TYPE 475) CALCULATIONS 1 INCH CORNING, JOHNS MANVILLE, 3M FIRE WRAP 1 INCH INSULATED BACKSPLASH ETL LISTING DESCRIPTION 3 INCH UN-INSULATED AIRSPACE PLENUM THE CAPTIVE AIRE MODEL THESE RATINGSNAPPLY TOP PY TOP, ENDS, BACK CAPTIVE-AIRE HOODS ARE AND FRONT OF THE EXHAUST HOOD SND—2 HAS BEEN E.T.L. BUILT IN COMPLIANCE WITH REPORT NUMBER: 3054804-001 INTERTE TESTINGTESTED, LISTED, AND >Mz ISSUED 11/2004 TO AICES PTIVENAIRECSYSTEMS APPROVED TO EXHAUST NSF ��;�E J Ha 88 A MINIMUM OF 294 CFM PER JOB Concession Stand Hood NFPA #96 — LOCATION South Windsor, CT LINEAR FOOT NSF ♦� � Aff�� �" OVER 600 DEGREE COOKING UL 710 & ULC710 STANDARDS DATE 1/24/2011 JOB # 122'783'7 EQUIPMENT E.T.L. LISTED 3054804-001 =_= DWG // 1 DRAWN BY SAC REV SCALE 1/32 EXHAUST FAN INFORMATION FATUNITN FAN UNIT MODEL # MODEL TAG CFM S.P. RPM H.P. 0 1 VOLT I FLA WEIGHT (LBS.) NO. 1 NCA14FA NCA14FA 2655 0.850 1346 1.000 1 115 14.0 133.14 FAN OPTIONS FAN UNIT OPTION (Qty. — Descr.) NO. 1 I1 — Grease Box CURB ASSEMBLIES NO. FAN ITEM SIZE 1 # 1 Curb 23.000"W x 23.000% x 20.000"H 4.000:12.000 Pitch FAN #1 NCA14FA - EXHAUST FAN 33 3/4 FEATURES: 23" - ROOF MOUNTED FANS 23'p - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT CURB - HIGH HEAT OPERATION 300°F (149°C) 20» - GREASE CLASSIFICATION TESTING n. 30 1/2 NORMAL TEMPERATURE TEST 20 STEEL 23 GAUGE EXHAUST FAN MUST OPERATE CONTINUOUSLY CONSTRUCTION WHILE EXHAUSTING AIR AT 300°F (149-C) REACHEDUNTIL ALL FAN PARTS HAVE THERMAL EQUILIBRIUM, AND WITHOUT ANY _ DETERIORATING EFFECTS TO THE FAN WHICH 3" FLANGE WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS ROOF OPENING T AT 600°F (316°C) FOR A PERIOD OF 20 DIMENSIONS 15 MINUTES WITHOUT THE FAN BECOMING 20 14 7/8 DAMAGED TO ANY EXTENT THAT COULD CAUSE 17 7/8 35 3/4 AN UNSAFE CONDITION. 20 OPTIONS PITCHED CURBS ARE AVAILABLE 4 FOR PITCHED ROOFS. 24 3/4 -- 18° GREASE BOX SPECIFY PITCH: 12 EXAMPLE: 7/12 PITCH = 30° SLOPE DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) JOB Concession Stand Hood LOCATION South Windsor, CT W • MAr" — — — a DATE 1/24/2011 JOB # 1227837 DWG # 1 DRAWN BY SAC REV SCALE 1/32 EXHAUST FAN TO BE cENwIO CASKET EXHAUST FAN TO LOCATED 10' FROM AIR GENERAL NOTES HINGE OPEN FOR , ` COMCAL SPRING INTAKES, WI DOORS AND NDOWS. CLEANING AND , �� INSPECTION �;; ,,,� TYPE 1 HOOD TO OVERHANG COOKING EQUIPMENT BY MIN OF 6 ON ALL SIDES.(COOKING EQUIPMENT BY00 �rG OTHERS AND NOT TO EXCEED 8' IN TOTAL LENGTH) U) CLEANABLE GREASE U DOOR DUCT TAM TYPE 1 EXHAUST DUCTWORK TO BE CONSTRUCTED OF 16 GAUGE STEEL, WELDED LIQUID TIGHT. �I 4140 CATCHHIGH TEMP ACCESS DOORS TO BE INSTALLED AT CHANGE OF DIRECTION IN EXHAUST DUCTWORK Dr- " SUPPLY AIR IS TO BE INTRODUCED THROUGH THE 2-5' PASS THROUGH WINDOWS. '� wGENERIC DRAWING WINDOWS NEED TO BE OPEN TO OPERATE THE STAND.ROOF MAY BE 1 INSTALLATION OF HOOD AND DUCTWORK TO MEET I.M.C. 2003 STANDARDS -4. O Lj FROM THE SHORT DE DOOR PITCH . ALL DIM. ARE BOLT QED 10 lliRER DOOR ELECTRICAL CONNECTIONS BY OTHERS. `' 0 >Q OF THE CURB OR FAN 7171070117 8 GA BACKING PLATE FIRE SUPPRESSION SYSTEM BY OTHERS. x ___i Q:2 EXHAUST DUCTWORK TO BE Q 0 INSULATED WITH UNIFRAX DUCTMATE HIGH TEMP ACCESS DOOR L` Q ULTRA GREASE DUCT WRAP I U� WHERE 18" TO COMBUSTIBLES � ~w LL CAN NOT BE OBTAINED. p W LJ 0 —I Z Z DUCT TO HOOD = 0 d Do QU N ROOF PENETRATION ' O cq 00 = w c OO z 0 DE - o � a EF EF a U) U1 14 �D 12 14/1 W W z SO' TYPE 1 HOOD 00 W SERVICE a' WINDOW W WALL CONSTRUCTED OF I" META4 STAINLESS EL WAL PANELS CHANNELS AND 5/8" SHEETROCK B, s,> 24" 16" 16" 48" STOVE FRYEF FRYER GRIDDLE r� Z Q U) v Y Z Q� 0 0 0 (n in w Q § O U rj 0 z O �`'o U Of Nn Li U w ~ 3 0 J SCALE None DRAWN BY PPS DATE 02 24 11 REVISIONS Dwg. No. H_1 HOOD INFORMATION SPECIFICATIONS: SND-2 MODEL EXHAUST PLENUM SUPPLY PLENUM HOOD CONFIG. SWITCHES HOOD MAY TOTAL RISERS TOTAL RISERS HOOD MODEL LENGTH COOKING END TO THE MODEL SND IS AN EXHAUST CANOPY HOOD WITH A SLOPED NO. EXH. SUP. CONSTRUCTION ROW QUANTITY LOCATION TEMP. CFM WIDTH LENG. DIA. CFM S.P. CFM WIDTH LENG. DIA. CFM S.P. END FRONT WHICH IS UL LISTED AS EXHAUST HOOD WITHOUT DAMPER (FILE MH12106). ' 10" 24" 2655 -0.609" 430 SS FRONT THE HOOD COMPONENTS SHALL BE FABRICATED OF TYPE 430 4812 9 0.00 60fl 2655 0 ALONE ALONE 11 LIGHT RIGHT 1 SND-2 Deg. Where Exposed FACE STAINLESS STEEL, #3 OR #4 POLISH, ON ALL EXPOSED SURFACES. CONSTRUCTION SHALL BE IN ACCORDANCE WITH NFPA 96. THE HOOD SHALL BE PROVIDED WITH HANGING ANGLES ON EACH END OF THE HOOD. AN ADDITIONAL SET OF HANGING ANGLES HOOD INFORMATION WILL BE PROVIDED FOR HOODS GREATER THAN 12' IN LENGTH. FILTERS LIGHTS UTILITY CABINETS FIRE HOOD HOOD WIRE FIRE SYSTEM ELECTRICAL SWITCHES SYSTEMHANGINC THE HOOD SHALL BE FITTED WITH U.L. 1046 STAINLESS STEEL NO. TYPE QTY. HEIGHT LENGTH QTY. TYPE GUARD LOCATION TYPE SIZE MODEL # QUANTITY LOCATION PIPING WGHT BAFFLE FILTERS WHICH ARE EASILY REMOVABLE FOR CLEANING. THE FILTERS WILL DRAIN THE GREASE INTO A SLOPED GREASE 3 16" 16" 3 Incandescent Light Fixt NO NO 310 DRAIN SYSTEM WITH REMOVABLE 1/2 PINT CUP FOR EASY CLEANING. 1 SS Baffle with Handles 3 16" 20" LBS HOOD LIGHTS SHALL BE U.L. LISTED SUITABLE FOR GREASE HOODS AND SHALL BE SUPPLIED WITH PLASTIC COATED GLOBES. EACH LIGHT WILL ACCOMMODATE UP TO A STANDARD 100 WATT BULB. ALL LIGHTS WILL BE PRE-WIRED TO JUNCTION BOXES ON TOP OF THE HOOD. HOOD DIMENSIONS SHALL BE AS SHOWN ON DRAWINGS. 48" INCANDESCENT LIGHT FIXTURE-HIGH TEMP FIELD CUT EXHAUST RISER ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) HANGING ANGLE 16" SS BAFFLE WITH 12" NOM. HANDLES AND HOOK 3" INTERNAL STANDOFF O F Field Cut 10" X 24" IT IS THE RESPONSIBILITY _ _ _ _ J Exhaust OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE Riser FROM LIMITED-COMBUSTIBLE 27" MIN. ---I AND COMBUSTIBLE MATERIALS 48 0 MAX U.L. Listed Incandescent Light IS IN COMPLIANCE LOCAL CODE REQUIREMENTS. 48'� Fixture—High Temp Assembly GREASE DRAIN 92" WITH REMOVABLE CUP 80" AFF TYP. EQUIPMENT FIFO I BY OTHERS FAN & LIGHT SWITCH 9' 0.00"Nom./9' 0.00"OD - SECTION VIEW - MODEL 4812SND-2 DaMIST CFM=LENGTH OF HOOD X CFM/UN.FT. (LOAD) PLAN VIEW - Hood 1 SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED TOTAL DUCT AREA=144 X C 9 ' 0 .0 0" LONG 4 812 S N D - 2 TOTAL DUCT AREA onn-N DUCT LENGTH= DUCT DEPTH PLEASE NOTE: THE HOOD MAY BE INSTALLED =CAPTIVE-AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST WITH A 0 INCH CLEARANCE TO COMBUSTIBLE VELOCITY OG 1600-1800 FPM AND A SUPPLY VELOCITY OF 1000 FMP. MATERIALS IF CONSTRUCTED IN ONE OF THE PLEASE CONSULT FACTORY FOR MAXIMUM ALLOWABLE DUCT SIZES FOLLOWING METHODS: CALCULATIONS UTILIZED 1 INCH LAYER OF INSULATION (TYPE 475) OWENS CORNING, JOHNS MANVILLE, 3M FIRE WRAP 1 INCH INSULATED BACKSPLASH ETL LISTING DESCRIPTION 3 INCH UN-INSULATED AIRSPACE BACK-RETURN (BR) SLIPPY PLENUM THE CAPTIVE AIRE MODEL CAPTIVE-AIRE HOODS ARE THESE RATINGS APPLY TO TOP, ENDS, BACK AND FRONT OF THE EXHAUST HOOD SND—2 HAS BEEN E.T.L. BUILT IN COMPLIANCE WITH REPORT NUMBER: 3054804-001 INTERTEK TESTING SERVICES NA INC. TESTED, LISTED, AND ISSUED 11/2004 TO CAPTIVE-AIRE SYSTEMS APPROVED TO EXHAUST NSF ���s nno,_ ') A MINIMUM OF 294 CFM PER JOB Concession Stand Hood NFPA #96 — LOCATION South Windsor, CT LINEAR FOOT NSF ♦% — Aff Aff AW — — __= DATE 1/24/2011 JOB # 1227837 OVER 600 DEGREE COOKING UL 710 & ULC710 STANDARDS , ram= EQUIPMENT E.T.L. LISTED 3054804-001 DWG # 1 DRAWN BY SAC REV. SCALE 1/32 I_'iA.".liUST n1YT I1VTlV1b111imIV1Yr FAN UNIT FAN UNIT MODEL # MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) NO. 1 NCA14FA NCA14FA 2655 0.850 1346 1.000 1 115 14.0 133.14 FAN OPTIONS FAN UNIT OPTION (Qty. — Descr.) NO. 1 1 — Grease Box CURB ASSEMBLIES N0, FAN ITEM SIZE 1 # 1 Curb 23.000"W x 23.000"L x 20.000"H 4,000:12.000 Pitch FAN #1 NCA14FA - EXHAUST FAN 33 3/4 FEATURES: 23" — ROOF MOUNTED FANS 23» — RESTAURANT MODEL — UL705 AND UL762 — AMCA SOUND AND AIR CERTIFIED — WIRING FROM MOTOR TO DISCONNECT SWITCH — WEATHERPROOF DISCONNECT CURB — HIGH HEAT OPERATION 300°F (149°C) 20" — GREASE CLASSIFICATION TESTING 2 a NORMAL TEMPERATURE TEST 20 GAUGE 30 1STEEL / EXHAUST FAN MUST OPERATE CONTINUOUSLY CONSTRUCTION 23 WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH �� _ 3" FLANGE WOULD CAUSE UNSAFE OPERATION. 2 ABNORMAL FLARE—UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS / ROOF OPENING AT 600°F (316°C) FOR A PERIOD OF 20 DIMENSIONS 15 MINUTES WITHOUT THE FAN BECOMING 20 14 7/8 DAMAGED TO ANY EXTENT THAT COULD CAUSE 17 7/8 35 3/4 AN UNSAFE CONDITION. 20 OPTIONS PITCHED CURBS ARE AVAILABLE 4" 24 3/4 FOR PITCHED ROOFS. O GREASE BOX 18 SPECIFY PITCH: 12 EXAMPLE: 7/12 PITCH = 30° SLOPE DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) JOB Concession Stand Hood __ _ LOCATION South Windsor, CT AV AW M AF" — — _— DATE 1/24/2011 JOB # 1227837 %mmAwiff I w DWG # 1 DRAWN BY SAC REV. SCALE 1/32 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# TOWN OF SOUTH WINDSOR Applic b6 BUILDING DEPARTMENT -- P 1540 SULLIVAN AVENUE LIS-- 644-2511 ext. 230Bldg'Permit# Y _ Date �ildingr Application must be printed or typed FEE SCHEDULE Fent Locationof Job: $0-$1,000=$15.00 Street Lot No.Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt. No. APPLICANT J,4U,c /5 L lcc:' APPLICANT ADDRESS to , T J4,w IA(4 1 w, — APPLICANT PHONE# OW N St OWNER ,.:/ s� Cam, LU• ✓c .Si'l' -— OWNER ADDRESSyet_— OWNER PHONE C ESTIMATED COST$ sN * IS THIS A CONTRACT COST,? !n'�-, ,Yes _No FEE ENCLOSED$ nf p20e6t 1 TYPE OF JOB: �SOR•CO� ew Installation Alteration/Addition/Repair APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? 0 YES ❑NO ❑ RESIDENTIAL ❑ BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ACTORY ENGINEER'S NAME PHONE STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE I Olj SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES _NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. /O- /D -fo CONTRACTORS LICENSE TYPE STATE �9 SIGNATURE OF APPLICANT - �<" _ DATE DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is ereb : TOWN OF SOUTH WINDSOR PERMIT# Geo�� BUILDING DEPARTMENT P D 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 a2� Date jB (in Inspector Application must be printed or typed FEE SCHEDULE Location of Job: -e s T - $0-$1,000=$15.00 Street No. Street Lot No. Over 1,000= ��� $15.00 per$1,000 JAL or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS 47�T- L11 060�� APPLICANT PHONE# d 60` 6,;?7- 60�o y OW N St OWNER Ta-t ' C1:;t —sLw+A w✓yij/.SdY, OWNER ADDRESS b ,. OWNER PHONE C ESTIMATED COST$ rl * U .� IS THIS A CONTRACT COST? Yes _No ` FEE ENCLOSED$ -_ TYPE OF JOB: SOR-CO ew Installation _Alteration/Addition/Repair ���� Revised 4/01//2002 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION Q SIZE OF MAIN DRAIN �l NO.OF TOILETS STYLE F4' NO.URINALS oZ STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES_ NO.OF CONDUCTORS SIZE NO.OF STACKS I — SIZE oZ AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS a� NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES ❑NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN ) ri SIZE OF WATER PIPING&RISER WATER HEATER: TYPE L-/tc-r MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HER BY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRI EDANDITT7— COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P- � i CONTRACTORS LICENSE NO. ,p TYPE STATE c SIGNATURE OF APPLICANT '/� �/'v �C. DATE 3 aC APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE 71 �j- SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR PE PE BUILDING DEPARTMENT ��25 APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# I 06 644-2511 ext. 230 �O� D' ate Building Inspector Application must be printed or typed FEE SCHEDULE Loc f Job: $0-$1,000=$15.00 F;T�e--nantDesignation / Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Apt.No. APPLICANT Q s I r✓/ (��' APPLICANT ADDRESS APPLICANT PHONE# ��S' S� 2-6 SOW N Sf,q OWNER OWNER ADDRESS OWNER PHONE 0 C / ESTIMATED COST$ ---�0 — IS THIS A CONTRACT COST. _Yes _No FEE ENCLOSED$ 'U — f�Y TYPE OF JOB: SO R C0 '`New Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED A BUILDING PERMIT APPLICATION? S ❑NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY j�/:�/ S?AC/E ❑ASSEMBLY❑ `J MERCANTILE ❑EDUCATIONAL FUTURE USE AND OCCUPANCY So G IC ee it /'"i Gf ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑MIXED USE 5 cues i-1 e d, CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD _ SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? REQ ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK _Re M d,l e- / L&C T R I C g L 4110 i 1 y 6 /3 V 13c, // r,AZ 4� 7'0 ©eodc.e 134 P — /1"CfD!z to !% /y 4?arlo- (�"-f/lvc THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. / Sa.9 53 C 7- CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 3--31—a K ;;; SION APPLICATION FOR ELECTRICAL PERMIT PERMIT# y: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT O c 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Ins for Application must be printed or typed FEE SCHEDULE Location of Job: _ 91ir L-SI( e-f $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT71 G Cd G C, APPLICANT ADDRESS _ 1 e2 Gt/l k( /7 0 ---. ._-- -Q Gl/z 04 d50 i G 7— o G G 7 L4 APPLICANT PHONE# 6 O o2 o w N S Fq OWNER 770 6Z& cJ i= 5'd e✓ K C./s a 12 < OWNER ADDRESS r �, 'r• OWNER PHONE 0 ESTIMATED COST$ IS THIS A CONTRACT COST? _Yes No l� A V FEE ENCLOSED$ /.1/101 dH � f��s000 TYPE OF JOB: R C _ Installation Alteration/Addition/Repair Revised4/01//2002 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT I�oa�3 APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 3 10 �� 644-2511 ext. 230 Date Building lnsoector Application must be printed or typed FEE SCHEDULE Location of Job: n �vi3 S Pa.(-/< $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT ,K�/`T 1,�CTRZC. APPLICAN -* DRESS Oyj2& APPLICANT PHONE# r -- ` OWN S F,q OWNER 7—cam CC— �� L(�I��•�� OWNER ADDRESS /Sq)5,21 T wt? Gt V e o. it OWNER PHONE 60 6 `[9--V C ESTIMATED COST$ IS THIS A CONTRACT COST? _,,Yes _No �" (�J�G FEE ENCLOSED$ `r o11 c2 coq Q oK� TYPE OF JOB: �S�R C O� New Installation —ZAlteration/Addition/Repair Revised 4/01//2002 1 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑MIW USE ti CITY STATE ZIP ( er Please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. /.2-S,2- 7 q —1 E' C� CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT (- �C�G � DATE �v Electric# APPLICATION FOR BUILDING PERMIT Plumbing# _ S%YY R013 Rye Street Date: Cf v8 0e HVAC # Sprinkler# 11 8 00 50 2 FINAL A� ----- _ — — ---- -- Estimated Cost $ i`t,caoU. Buildin ---- ----- - ---- _ - Permit Fee $ g Q q3 COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering TYPE OR PRINT ONLY En . Ins Fee $ Affidavit SIGN ON REVERSE SIDE / I g p PP ` _-- _---- -.-1 Total Fee $�A ' A r. or - - - _l TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the followi g: Applicant&,�Jtu kJIM0s0.i Vco� Faur644L.Location of Work R S' Lot No. Applicant's Address 4C K t''1ALM F T. Tel.# 1,41 Town So_ to i M17130yt- c i Zip c:6o-71-/ Lic.# Owner Architect "/-& Owner's Address Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 2nd Fl. 3rd FI. Total New Area Purpose of this permit S ccSEbo. fkO City W er❑ Well❑ Septic System❑ Sewero Ins: HO SP Cert. ea Basement Garage Approved bydr eUse Date Group Construction Type Revise�d18/02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the g6p r distance from all street lines,side yard lines,and required distances from all other zones and is located in which tLhiVrbu1IdZg Old its use is allgwed. Signed ✓ I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Electric # APPLICATION FOR BUILDING PERMIT Plumbing# SED R013 Rye Street HVAC# Date: Sprinkler#PERP FINAL APPIAASI _ .7 0 Estimated Cost $ S000 d Building AND COMPLETE RED BOXED AREAS Permit Fee $Occupancy Fee $ Engineering _fie "3 TYPE OFFPRINT ONLY Eng. Insp. Fee Affidavit Appr.forCO. ► SIGN ON REVERSE SIDE A Total Fee $ 11 TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant Me W Location of Work &1-e tT a*44 Lot No. Applicant's Address 621 s r Tel # Town Zip G-r Lic.# Q rrd 2Z Owner tv Architect Owner's Address _ Architect's Address Zip Zip— Sq. Ft.New Area: t st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit Alt-a.l l c- /Aj City Water!.) Well J Septic System J Sewer J Ins: HO SP Cert. ,p Area Basetn nt Garage Approved by Date a ' Use GroupzT Construction Typ`e� � ? Revised 1108 a2oo9t;�8's3 Clv1.) I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which t s bui ganand its a is allowed. Signedoc ' 6�yforth'.orkdescri I hereby apply for a Certificate din this application for the permit. Signed 6 i DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS i I