Loading...
HomeMy WebLinkAbout128 BERRY PATCH BUILDING 10 Electric# 1�313C1 APPLICATION FOR BUILDING PERMIT Plumbing# It 3 128 Berry Patch (Building 10) Date: IHVAC # 5--2 Sprinkler# /y FINAL APPROVALS Estimated Cost $ ?S ,000.00 Buildin Permit Fee $ g COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering TYPE OR PRINT ONLY Affidavit Eng. Insp. Fee $ Appr. for CO. IGN ON REVERSE SIDE / J Total Fee $—o TO THE BUILDING PARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant The Metro onGtnir-ti nn rni, Location of Work 128 Berry Patch Lot No. 1 H Applicant's Address 6 Executive Drive, Suite 100 Tel.# 860 674-5640 Town Farmington, Cr Zip 06032 Lic.# Mm gon434 Owner Berry Patch II Associates L.P. Architect Associated Architects Owner's Address 6 Executive Drive, Suite 100 Architect's Address 16 Spring Lane Farmington, Or Zip 06032 Farmington, CT Zip 06032 Sq. Ft. New Area: 1st Fl. 737 2nd FI. --- 3rd FI. --- Total New Area 737 Purpose of this permit New Const-nic-ti on - mill ti=l e single family affordable d{el6lling City Water[A Well❑ Septic System❑ Sewerk Ins: HO SP Cert. Area Basement Garage Approved by Date Use Group Construction Type Revised 6102 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and As use is allowed. rH Mc fRo CONSTHuCT!ON COH,- BIC Peter R nn,,JresidLn, Signed DtO � I hereby apply for a Certificate of Occupancy for the work described in this appli ion4forthepermit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS ` Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-31276-B 15,000 B02 FOUNDATION 04/27/05 PJP A EAST WALL B04 INSULATION 04/28/05 PJP A INSULATION FROST WALL BO1 FOOTING 05/03/05 PJP A HIGH WALL B02 FOUNDATION 05/06/05 PJP A HIGH WALL MAT P02 UNDERGROUND 05/19/05 PJP A EAST P02 UNDERGROUND 05/24/05 PJP A MID PO4 GAS TEST 09/14/05 PJP A B03 FRAMING (ROUGH) 09/22/05 PJP A E03 ROUGH 09/22/05 PJP A P03 ROUGH 09/22/05 PJP A B04 INSULATION 10/03/05 PJP A B10 FINAL 12/23/05 PJP A W/CJD **-1452-5 2,000 **-12576-H 6,000 **-11835-P 5,000 **-19399-E 2,700 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 1 �— BUILDING DEPARTMENT - RO 1540 SULLIVAN AVENUE ._. - Bldg.Permit# iA. 320 644-2511 ext. 230 3 I (-)�^7(o Date Building Inspect Application must be printed or typed FEE SCHEDULE Location of Job: FT-enantDesignation Berry Patch 1H $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 _ or any fraction thereof Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# (860) 623-1991 _ Ow N s Fq OWNER Berry Patch II Associates Limited Partnership < OWNER ADDRESS 6 KKecutive Drive, Suite 100 �.`. Farmington, Cr 06032 OWNER PHONE (860) 674-5641 y. ESTIMATED COST$ 5,000.00 WrA IS THIS A CONTRACT COST? X Yes _No �G FEE ENCLOSED$_75.00 O�� TYPE OF JOB: 0R•C X New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑NIIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4" NO. OF TOILETS 1 STYLE ElOn9ated NO.URINALS N/A STYLE N/A NO. OF BATHTUBS NO. OF SHOWERS 1 NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3 AREA OF ROOF Back NO. OF CATCH BASINS N/A NO.OF FLOOR DRAINS 1 Kitchen NO.OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES 92 NO SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4 Weil Mclain WATER HEATER: TYPE Indirect MANUFACTURER P/US 120 DESCRIPTION OF WORK THE UNDERSIuNED HEREBY APPLIES FOR A PERMIT TO PERTORMTHE WORK DESCRIBED AND 17T7— COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P-1 00204480 P-1 Cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT G� DATE DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# TOWN OF SOUTH WINDSOR Application is hereby: l BUILDING DEPARTMENT l"l t 4Building 1540 SULLIVAN AVENUE 644-2511 ext. 230Bldg. Permit# Dete4), Application must be printed or typed FEE SCHEDULE Location of Job: FDesignation Berry Patch $0-$1,000=$15.00 1H Over$1,000= Street Lot No. $15.00 per$1,000 or any fraction thereof Apt.No. APPLICANT J—Electric APPLICANT ADDRESS 8 Sanrico Drive Manchester, Cr 06040 APPLICANT PHONE# (860) 645-9891 O W N SF OWNER Berry Patch II Associates Limited Partnership < OWNER ADDRESS 6 Rwutive Drive, Suite 100 CIOF , Cr 06032 Q OWNER PHONE (860) 674-5641 ESTIMATED COST$ 2,700.00 x IS THIS A CONTRACT COST? X Yes —No FEE ENCLOSED$ 45.00 S.O R.C O�� TYPE OF JOB: XNew Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑YES ❑NO M RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑ MERCANTILE FUTURE USE AND OCCUPANCY Residence ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME EA3/CJL &Xgi reeri r PHONE `(860) 257—3968 ❑ STORAGE ❑GARAGE ADDRESS 203 Briarw")d Court ❑MIXED USE CITY Rocky Hill STATE Cr Z p 06067 (Other please specify) TYPE OF INSTALLATION/WIRING METHOD NMC SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS #2 Al NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8 NUMBER OF SWITCHES 10 NUMBER OF OUTLETS 18 NUMBER OF LIGHT FIXTURES 7 NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS 1 SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Interior wiring of apartment to include outlets, switches and their cover plates. Wiring of appliances and HVAC unit. Install light fixtures. Install 100 amp breaker panel. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 123580 E-1 CT C EN CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT '� �-h DATE DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT N S� APPRO 1540 SULLIVAN AVENUE ��+��-��� Q 644-2511 ext. 230 Bldg.Permit# Z!!!' Date-LO4uilding Insp or Application must be printed or typed FEE SCHEDULE Location of Job: FTenant A Berry Patch 1 H $0-$1,000=$15.00 o. Street - Over$1,000= Lot No. $15.00 per$1,000 or any fraction thereof Designation Apt.No. - APPLICANT Thomas L. Jacquel c/o Allstate Fire Sprinkler, Inc. APPLICANT ADDRESS P.O. Box 2350 Hartford, cr 06146 APPLICANT PHONE# (860) 246-1711 � 0W N SFq OWNER Berry Patch II Associates Limited Partnership OWNER ADDRESS 6 Executive Drive, Suite 100 Farmirx ton► CT 06032 OWNER PHONE (860) 674-5641 r ` ESTIMATED COST$ 2 ,000.00 . V ' IS THIS A CONTRACT COST? X Yes _No �1.r � FEE ENCLOSED$ 3 0.0 0 TYPE OF JOB: SpR,C0 %New Installation Alteration/Addition/Repair APPLICATION FOR SPRINKLER PERMIT (Continued from reverse side) TYPE OF BUILDING TYPE OF CONSTRUCTION 5B USE GROUP NO. OF STORIES �RESIDENTIAL El BUSINESS IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PERMIT APPLICATION? El YES El NO ❑MERCANTILE ❑EDUCATIONAL CURRENT USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ❑ STORAGE ❑ GARAGE ENGINEER'S NAME David R• Thoulpsm PHONE(860) 246-7711 ❑MIXED USE (Other please specify) ADDRESS P.O. Bcx 2350 CITY Hartford STATE CT ZIP 06146 KIND OF P%ISTALLATION SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI) ARE SPRINKLER HEADS ALTERED? N YES ❑NO IF YES,CHECK ALL THAT APPLY: ADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) ❑PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES IN NO IF YES,CHECK ALL THAT APPLY: ❑FIRE ❑BOOSTER ❑ OTHER ARE STANDPIPES PROVIDED? ❑YES M NO IS A SPRINKLER SYSTEM PROVIDED? ®YES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP N/A PSI DESCRIPTION OF WORK New fire sprinkler system in one bedroom unit THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORD DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. F10590 Fire Sprinkler Cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT ��S APP_ VED 1540 SULLIVAN AVENUE J L 2 7 644-2511 ext, 230 Bldg.Per/mit# Date Buildi Inspector 3 1 A _ Application must be printed or typed r FEE SCHEDULE Location of Job: $0-$1,000=$15:00 — 128 wry Patch 1 H Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Fahrenheit Mechanical services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# . (860) 623-1991 SOW N SF•q OWNER Berry Patch II Associates Limited Partnership < OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr. 06032 O a E.r OWNER PHONE (860) 674-5641 ESTIMATED COST$ 6 ,0 0 0. 0 0 ►� : U IS THIS A CONTRACT COST? X Yes —No j r �CJ FEE ENCLOSED$ 9 0 . 0 0 So .Co � TYPE OF JOB: X New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR RVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: M HEATING kkRESIDENTIAL ®A/C ❑ COMMERCIAL 2 VENTILATION ❑INDUSTRIAL HEATING C7 STEAML LOW PRESSURE LIMIT LBS. HIGH PRESSURE I= LBS. HYDRONIC 92 WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) T(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Armstrong Magic Pak , 38HWC183A-3 GROSS HEATING CAPACITY(LNPUT—BTUH) 38,000 NET RATING(OUTPUT—BTUH) 30,000 TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑INSIDEQ OUTSIDE CAPACITY ® GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE of P e r TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) Plans DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) A Specs TONNAGE 1 COOL-LNG CAPACITY(BTUH) 18,0 0 0 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 600 FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 303755 S-1 CT CONTRACTORS LICENSE NO. STATE .- a_ os SIGNATURE OF APPLICANT DAB c