HomeMy WebLinkAbout125 LONGMEADOW DR REScheck Software Version 4.6.5 SCANNED
Compliance Certificate
Project The Palmerton Model
Energy Code: 2012 IECC
Location: Hartford, Connecticut M-
Construction Type: Single-family �
t►P.Ct%r C.M:.
Project Type: New Construction *« .
Conditioned Floor Area: 5,157 ft2
t.
Glazing Area 12% ,,,.,
Climate Zone: 5 (6155 HDD)
Permit Date: 04/03/19 ,rb. • -
Permit Number: 0024
Construction Site: Owner/Agent: Designer/Contractor:
Estates at South Windsor Toll Brother, Inc. Toll Brothers-lrlc
125 Longmeadow Drive 250 Gibraltar Road
South Windsor, CT 06074 Horsham, PA 19044
Compliance: Passes using UA trade-off
Compliance: 1.9%Better Than Code Maximum UA: 428 Your ILIA: 420
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Perimeter
Basement Wall 1: Solid Concrete or Masonry 1,352 0.0 19.0 0.039 52
Wall height: 7.5'
Depth below grade:6.5'
Insulation depth: 7.5'
Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.300 4
Door 3:Solid 18 0.200 4
First Floor 2x6 Walls: Wood Frame, 16"D.C. 1,299 21.0 0.0 0.057 58
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 259 0.300 78
Door 1: Solid 20 0.300 6
Garage Wall:Wood Frame, 16" o.c. 325 13.0 0.0 0.082 25
Door 2:Solid 18 0.300 5
Second Floor 2x6 Walls:Wood Frame, 16"D.C. 1,311 21.0 0.0 0.057 67
Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 132 0.300 40
Band joists:Wood Frame, 16"D.C. 329 21.0 0.0 0.057 19
Flat Ceiling: Flat Ceiling or Scissor Truss 2,077 38.0 0.0 0.030 62
Project Title:The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 1 of 9
190356-TB I-0024.rc k
� ' s � ' r*
? i �„�
Compliance Statement: The proposed building design described here is consistent„yN11;h,XOe building plans,specifications,and other
calculations submitted with the permit application.The proposed building ha\�.b�'en rift4a meet the 2012 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements limed h K'nspection Checklist.
Jeremy Greene, AIA, Director of Architecture ., : F'••i = 04-11-2019
Name-Title Signature_ !fin;C Date
Project Notes: • '. J
Elevation: Woodbury Fes•• �a j
V
"9 ARC���
nnun
Project Title:The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 2 of 9
190356-TBI-0024.rck
REScheck Software Version 4.6.5
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Se Lion Pre-Inspection/Plan Review Plans Verified Field Verified Complies? Comments/Assumptions
& Req.ID I Value Value
103.1, ;Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1)1 energy code compliance for the
building envelope. ❑Not Observable
❑Not Applicable
103.1. ;Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 ;energy code compliance for
[PR311 lighting and mechanical systems. []Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.6 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[1311212 ;on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
d, ;Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low impact(Tier 3)
Project Title:The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 3 of 9
190356-TBI-0024.rck
section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? i Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[F04]1 insulation R-value.Where interior R R ❑Does Not table for values.
insulation is used,verification .[:]Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 ;Conditioned basement wall ❑Complies
[F05]1 :insulation installed per ❑Does Not
manufacturer's instructions. []Not Observable
❑Not Applicable
402.2.8 ;Conditioned basement wall ft ft ❑Complies ;see the Envelope Assemblies
[F06]1 insulation depth of burial or ❑Does Not ;table for values.
j distance from top of wall. j❑Not Observable
[]Not Applicable
303.2.1 :A protective covering is installed ❑Complies
[FO11]2 :to protect exposed exterior ❑Does Not
R� insulation and extends a
minimum of 6 in. below grade. []Not Observable
❑Not Applicable
403.8 ;Snow-and ice-melting system ❑Complies
[FO12]2 ;controls installed. ❑Does Not
_< ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 4 of 9
190356-TBI-0024.rck
Section Plans Verified Field Verified
# Framing/Rough-In Inspection I Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ;❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, []Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 :are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable
;taken from the default table.
[]Not Applicable
402.4.1.1 :Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
QNot Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
�AAMA/WDMA/CSA 101/I.S.2/A440 []Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
402.4.4 ;IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
:and labeled to indicate <_2.0 cfm
leakage at 75 Pa. QNot Observable
❑Not Applicable
403.2.1 Supply ducts in attics are R- R- ❑Complies
[FR12]1 insulated to >_R-8.All other ducts R- R- ❑Does Not
in unconditioned spaces or QNot Observable
outside the building envelope are
insulated to zR-6. ❑Not Applicable
403.2.2 ;All joints and seams of air ducts, - =?❑Complies
[FR13]1 air handlers,and filter boxes are ❑Does Not
sealed. r '.
E]Not Observable
;❑Not Applicable
403.2.3 ;Building cavities are not used as ❑Complies
[FR15]3 ;ducts or plenums. - f . ❑Does Not
Y_
r:f
a
❑Not Observable ,
E ❑Not Applicable
403.3 ;HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 :above 105 QF or chilled fluids ❑Does Not
dJ 3elow 55 QF are insulated to aR- j ;QNot Observable
❑Not Applicable
403.3.1 Protection of insulation on HVAC ; - _ a❑Complies
[FR2411 piping. : - =_a❑Does Not
jQNot Observable
ti ;❑Not Applicable
403.4.2 ;,Hot water pipes are insulated to R- R- ❑Complies
IFR1812 :zR-3. ❑Does Not
QNot Observable
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title:The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 5 of 9
190356-TBI-0024.rck
r '
Section Plans Verified Field Verified
4 Framing/ Rough-In Inspection Value Value I Complies? t Comments/Assumptions
& Req.ID
403.5 Automatic or gravity dampers are ❑Complies
[FR19]2 ;installed on all outdoor air ❑Does Not
:intakes and exhausts. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title:The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 6 of 9
190356-TBI-0024.rck
Section Plans Verified Field Verified
& Re ID Insulation Inspection Value Value Complies? i Comments/Assumptions
q'
303.1 All installed insulation is labeled ❑Complies
[IN1312 or the installed R-values ❑Does Not
d ;provided. ❑Not Observable
❑Not Applicable
402.1.1, "Wall insulation R-value.If this is a! R- R- I❑Complies ;See the Envelope Assemblies
402.2.5. mass wall with at least'h of the ❑ Wood ❑ Wood ❑Does Not ;table for values.
402.2.E wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]' ;exterior,the exterior insulation
requirement applies(FR10). ;❑ Steel ;❑ Steel ;❑Not Applicable
303.2 Wall insulation is installed per ;❑Complies
[IN4]' manufacturer's instructions. ❑Does Not
V ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title:The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 7 of 9
190356-TBI-0024.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Re .ID
402.1.1, ;Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not ;table for values.
402.2.2, ❑ Steel ❑ Steel ❑
402.2.E Not Observable '
[FI1]1 ❑Not Applicable
303.1.1.1, ;Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
(FI211 :Blown insulation marked every
0 ;300 ft2. ❑Not Observable
❑Not Applicable
402.2.3 :,Vented attics with air permeable ❑Complies
[FI22]2 :insulation include baffle adjacent ❑Does Not
;to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[FI3]1 insulation zR-value of the ❑Does Not
adjacent assembly. ❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[FI17]1 ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
handler @ 25 Pa. For rough-in
;tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.2.2.1 Air handler leakage designated []Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow. o
❑Not Observable
j -❑Not Applicable
403.1.1 !,Programmable thermostats ❑Complies
[FI9]2 installed on forced air furnaces. El
Does Not
d, 1❑Nat Observable
❑Not Applicable
403.1.2 ;Heat pump thermostat installed '❑Complies
[FI10]2 :on heat pumps. [ _ ❑Does Not
;❑Not Observable
❑Not Applicable
403.4.1 ;Circulating service hot water - 11Complies
[FI11]2 systems have automatic or ❑Does Not
;accessible manual controls. 1
L; ❑Not Observable
❑Not Applicable
403.5.1 ;All mechanical ventilation system, ❑Complies
[F[25]2 :fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacyT
�I
;and airflow limits. ❑Not Observable
❑Not Applicable
404.1 ;75%of lamps in permanent r , ': � '� 7 ']❑Complies
[1`16]1 fixtures or 75%of permanent f f- 4 ❑Does Not
;fixtures have high efficacy lamps `+ sit
❑Not Observable
;Does not apply to low-voltage }
lighting. } ; #erg ❑Not Applicable
11 High Impact(Tier 1) Z Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title:The Palmerton Model Report date: 04/11/19
Data filename: C:\ Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\A0- Page 8 of 9
190356-TBI-0024.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Re .ID
404.1.1 'Fuel gas lighting systems have IlComplies
IF123]3 ;no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
401.3 Compliance certificate posted. ❑Complies
[FI7]2 ❑Does Not
d: ❑Not Observable
❑Not Applicable
303.3 ;Manufacturer manuals for ❑Complies
[FI18]3 :mechanical and water heating []Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: The Palmerton Model Report date: 04/11/19
Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 9 of 9
190356-TBI-0024.rck
l�( 2012 IECC Energy
j Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 19.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC Window 0.30
Door 0.30
CoolingHeating &
Heating System:
Cooling System:
Water Heater:
Name: Jeremy Greene, AIA Date: 04-11-2019
Comments