Loading...
HomeMy WebLinkAbout125 LONGMEADOW DR REScheck Software Version 4.6.5 SCANNED Compliance Certificate Project The Palmerton Model Energy Code: 2012 IECC Location: Hartford, Connecticut M- Construction Type: Single-family � t►P.Ct%r C.M:. Project Type: New Construction *« . Conditioned Floor Area: 5,157 ft2 t. Glazing Area 12% ,,,., Climate Zone: 5 (6155 HDD) Permit Date: 04/03/19 ,rb. • - Permit Number: 0024 Construction Site: Owner/Agent: Designer/Contractor: Estates at South Windsor Toll Brother, Inc. Toll Brothers-lrlc 125 Longmeadow Drive 250 Gibraltar Road South Windsor, CT 06074 Horsham, PA 19044 Compliance: Passes using UA trade-off Compliance: 1.9%Better Than Code Maximum UA: 428 Your ILIA: 420 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Basement Wall 1: Solid Concrete or Masonry 1,352 0.0 19.0 0.039 52 Wall height: 7.5' Depth below grade:6.5' Insulation depth: 7.5' Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.300 4 Door 3:Solid 18 0.200 4 First Floor 2x6 Walls: Wood Frame, 16"D.C. 1,299 21.0 0.0 0.057 58 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 259 0.300 78 Door 1: Solid 20 0.300 6 Garage Wall:Wood Frame, 16" o.c. 325 13.0 0.0 0.082 25 Door 2:Solid 18 0.300 5 Second Floor 2x6 Walls:Wood Frame, 16"D.C. 1,311 21.0 0.0 0.057 67 Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 132 0.300 40 Band joists:Wood Frame, 16"D.C. 329 21.0 0.0 0.057 19 Flat Ceiling: Flat Ceiling or Scissor Truss 2,077 38.0 0.0 0.030 62 Project Title:The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 1 of 9 190356-TB I-0024.rc k � ' s � ' r* ? i �„� Compliance Statement: The proposed building design described here is consistent„yN11;h,XOe building plans,specifications,and other calculations submitted with the permit application.The proposed building ha\�.b�'en rift4a meet the 2012 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements limed h K'nspection Checklist. Jeremy Greene, AIA, Director of Architecture ., : F'••i = 04-11-2019 Name-Title Signature_ !fin;C Date Project Notes: • '. J Elevation: Woodbury Fes•• �a j V "9 ARC��� nnun Project Title:The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 2 of 9 190356-TBI-0024.rck REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Se Lion Pre-Inspection/Plan Review Plans Verified Field Verified Complies? Comments/Assumptions & Req.ID I Value Value 103.1, ;Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1)1 energy code compliance for the building envelope. ❑Not Observable ❑Not Applicable 103.1. ;Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 ;energy code compliance for [PR311 lighting and mechanical systems. []Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [1311212 ;on loads calculated per ACCA Cooling: Cooling: ❑Not Observable d, ;Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low impact(Tier 3) Project Title:The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 3 of 9 190356-TBI-0024.rck section Plans Verified Field Verified # Foundation Inspection Value Value Complies? i Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R R ❑Does Not table for values. insulation is used,verification .[:]Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 ;Conditioned basement wall ❑Complies [F05]1 :insulation installed per ❑Does Not manufacturer's instructions. []Not Observable ❑Not Applicable 402.2.8 ;Conditioned basement wall ft ft ❑Complies ;see the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not ;table for values. j distance from top of wall. j❑Not Observable []Not Applicable 303.2.1 :A protective covering is installed ❑Complies [FO11]2 :to protect exposed exterior ❑Does Not R� insulation and extends a minimum of 6 in. below grade. []Not Observable ❑Not Applicable 403.8 ;Snow-and ice-melting system ❑Complies [FO12]2 ;controls installed. ❑Does Not _< ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 4 of 9 190356-TBI-0024.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection I Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ;❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, []Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 :are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable ;taken from the default table. []Not Applicable 402.4.1.1 :Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. QNot Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not �AAMA/WDMA/CSA 101/I.S.2/A440 []Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.4 ;IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not :and labeled to indicate <_2.0 cfm leakage at 75 Pa. QNot Observable ❑Not Applicable 403.2.1 Supply ducts in attics are R- R- ❑Complies [FR12]1 insulated to >_R-8.All other ducts R- R- ❑Does Not in unconditioned spaces or QNot Observable outside the building envelope are insulated to zR-6. ❑Not Applicable 403.2.2 ;All joints and seams of air ducts, - =?❑Complies [FR13]1 air handlers,and filter boxes are ❑Does Not sealed. r '. E]Not Observable ;❑Not Applicable 403.2.3 ;Building cavities are not used as ❑Complies [FR15]3 ;ducts or plenums. - f . ❑Does Not Y_ r:f a ❑Not Observable , E ❑Not Applicable 403.3 ;HVAC piping conveying fluids R- R- ❑Complies [FR17]2 :above 105 QF or chilled fluids ❑Does Not dJ 3elow 55 QF are insulated to aR- j ;QNot Observable ❑Not Applicable 403.3.1 Protection of insulation on HVAC ; - _ a❑Complies [FR2411 piping. : - =_a❑Does Not jQNot Observable ti ;❑Not Applicable 403.4.2 ;,Hot water pipes are insulated to R- R- ❑Complies IFR1812 :zR-3. ❑Does Not QNot Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 5 of 9 190356-TBI-0024.rck r ' Section Plans Verified Field Verified 4 Framing/ Rough-In Inspection Value Value I Complies? t Comments/Assumptions & Req.ID 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 ;installed on all outdoor air ❑Does Not :intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 6 of 9 190356-TBI-0024.rck Section Plans Verified Field Verified & Re ID Insulation Inspection Value Value Complies? i Comments/Assumptions q' 303.1 All installed insulation is labeled ❑Complies [IN1312 or the installed R-values ❑Does Not d ;provided. ❑Not Observable ❑Not Applicable 402.1.1, "Wall insulation R-value.If this is a! R- R- I❑Complies ;See the Envelope Assemblies 402.2.5. mass wall with at least'h of the ❑ Wood ❑ Wood ❑Does Not ;table for values. 402.2.E wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]' ;exterior,the exterior insulation requirement applies(FR10). ;❑ Steel ;❑ Steel ;❑Not Applicable 303.2 Wall insulation is installed per ;❑Complies [IN4]' manufacturer's instructions. ❑Does Not V ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 7 of 9 190356-TBI-0024.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, ;Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not ;table for values. 402.2.2, ❑ Steel ❑ Steel ❑ 402.2.E Not Observable ' [FI1]1 ❑Not Applicable 303.1.1.1, ;Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not (FI211 :Blown insulation marked every 0 ;300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 :,Vented attics with air permeable ❑Complies [FI22]2 :insulation include baffle adjacent ❑Does Not ;to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI3]1 insulation zR-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in ;tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.2.2.1 Air handler leakage designated []Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. o ❑Not Observable j -❑Not Applicable 403.1.1 !,Programmable thermostats ❑Complies [FI9]2 installed on forced air furnaces. El Does Not d, 1❑Nat Observable ❑Not Applicable 403.1.2 ;Heat pump thermostat installed '❑Complies [FI10]2 :on heat pumps. [ _ ❑Does Not ;❑Not Observable ❑Not Applicable 403.4.1 ;Circulating service hot water - 11Complies [FI11]2 systems have automatic or ❑Does Not ;accessible manual controls. 1 L; ❑Not Observable ❑Not Applicable 403.5.1 ;All mechanical ventilation system, ❑Complies [F[25]2 :fans not part of tested and listed ❑Does Not HVAC equipment meet efficacyT �I ;and airflow limits. ❑Not Observable ❑Not Applicable 404.1 ;75%of lamps in permanent r , ': � '� 7 ']❑Complies [1`16]1 fixtures or 75%of permanent f f- 4 ❑Does Not ;fixtures have high efficacy lamps `+ sit ❑Not Observable ;Does not apply to low-voltage } lighting. } ; #erg ❑Not Applicable 11 High Impact(Tier 1) Z Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Palmerton Model Report date: 04/11/19 Data filename: C:\ Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\A0- Page 8 of 9 190356-TBI-0024.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 404.1.1 'Fuel gas lighting systems have IlComplies IF123]3 ;no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not d: ❑Not Observable ❑Not Applicable 303.3 ;Manufacturer manuals for ❑Complies [FI18]3 :mechanical and water heating []Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Palmerton Model Report date: 04/11/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0024\Documents\AO- Page 9 of 9 190356-TBI-0024.rck l�( 2012 IECC Energy j Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 CoolingHeating & Heating System: Cooling System: Water Heater: Name: Jeremy Greene, AIA Date: 04-11-2019 Comments