HomeMy WebLinkAbout116 BERRY PATCH BUILDING 9 Electric# APPLICATION FOR BUILDING PERMIT
Plumbing# 11 '6 1 Co 116 Berry Patch (Building 9) Date: OC `
HVAC # /d S(e y - --
31257
Sprinkler# /4 L10 0
FINAL APPROVALS -- - Estimated Cost $ '
BuildingPermit Fee $�
COMPLETE RED BOXED AREAS Occupancy Fee $ / D
Engineering TYPE OR PRINT ONLY
Affidavit Eng. Insp Fee $
Appr. for CO. SIGN ON REVERSE SIDE Total Fee $ 3 �f t7
TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $
The undersigned hereby applies to do work according to the following.
Applicant The Metro Construction Corp. Location of Work 116 Berry Patch Lot No. 2S
Applicant's Address 6 Executive Drive, Suite 100 Tel. # 860-674-5640
Town Farmington, Cr Zip 06032 Lic. # M00.900434
Owner-Berry Patch II Associates L.P. Architect Associated Architects
Owner's Address 6 Executive Drive, Suite 100 Architect's Address 16 Spring Lane
Farm ngtQn, Cr Zip 06032 Farmington, CT Zip 06032
Sq. Ft. New Area: 1 st FI. sg6 2nd FI. --- 3rd FI. --- Total New Area s96
Purpose of this permit New Construction - multiple single family affordable dwelling
City Water Well❑ Septic System❑ Sewer[
Ins: HO SP Cert. Area Basement Garage
Approved by Date Use Group Construction Type
Revised GM2
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be k)cated the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this building and its use is allowed.
THE METRO CONSTRuCTIGN C01-
Signed B .PetarR�Dkn, idr n9
1 hereby apply for a Certificate of Occupancy for the work described in this a cation for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
Location of Job: AFFIDAVIT Additional Fee S 12 0.0 0
State of Connecticut
ss.South Windsor
County of Hartford
II 1 Owner
of_IM `e ro C0 r1.STTv L*i d�x Agent for the building erected
Contractor
under Permit No. 31257 issued by the Building Department of the Town of South Windsor being
duly sworn,make oath and say that the actual cost of the completed work autho a 'un r aid permit did not
exceed the most current accepted BOCA value of S
Signe
Subscribed and sworn to before me this day of A.D.20
Estimated Cost$ 2 2 , 0 0 0. 0 0
Difference: S_ Z-,-5Z ri R R
Notary Public
BUILDING INSPECTION DEPARTMENT
TOWN of SOUTH WINDSOR, CONNECTICUT
N A
C E R T I F �`C yA.: Ef w 3 FW QO"r U P A N C Y
ZONE , •� SAC' rf<;< ` _� w , anuary 25, 2006
This is to certifyAthat` 13"6pBERR�f.: g2Clf CTED u, r,permit
No. 31257 cc formw substaiit�id-;2y ta'°.tlt4 :xequireitte� is ,of the. Connecticut
Basic Buildingc dew a �m.s�.��; l t
9 •a d°yth�'icrn `n�`r�gu2`aCi6ns a Ch+e,�;Ttiwn, f
c
South Windsor d
nT3 ai heYeb 'a rCved` faz" .a8
�u�is��c�'�k .'kn°c}icated below
Approved for Ocbupac �1t1LTI-SINGI� ; I?A1XLY pWE1Rf;IN, •' �"
B I,DTNG .9)
< i +✓4.:s.>,, ;';a
Use Group R3 "'; . •,: <<^ �,�``u n M
Constr. Type 5B�,(
{. ,;:.:�...=ice-���r�-rw.^a.:.y'<•a i.. :g F`<.., tk
w8uioi)ag•Official
Ilk
Notice If this ce'Ytifica.td'�kis. I.os' or>�,des.troy d, a duplicate should
be obtained iTmediat y"'lroitR-tht"IBuill iing Department
An change or extensi6'n.,Qfft�he use h�rer3n Y 9 9�"<�..w.«a��Y_��> approved requires
a new certificate of occupancy.
r-
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-31257-B 22,000
B01 FOOTING 05/18/05 PJP A
**-1440-S 2,000
**-12564-H 6,000
**-11816-P 5,000
Total Est Value 37,700
Dwelling 896 45,024 00
Basement 0 0 00
Garage 0 0 00
Smoke Det 3 225 00
BOCA Value 45,275 88
Difference 7,575.88
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
TOWN OF SOUTH WINDSOR Application is hereby:
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE L 2 T720 Q , Bldg.Permit#
, 644-2511 ext. 230 B 5,�Dat ' w' t -
l mg s ec.or
Application must be printed or typed
FEE SCHEDULE Location of Job:
1�16 Berry Patch 2 S
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT Fahrenheit Mechanical Services Inc.
APPLICANT ADDRESS 56 Depot Street
Broad Brook, Cr 06016
APPLICANT PHONE# (860) 623-1991
04 S Fq OWNER _Berry Patch II Associates Limited Partnershig
OWNER ADDRESS 6 Executive Drive, Suite 100
t j Farmington, Cr. 06032
OWNER PHONE (860) 674-5641
p
ESTIMATED COST$6_,0 0 0 . 0 0
`S. IS THIS A CONTRACT COST? X Yes No
FEE ENCLOSED$ 90 . 00
OR-CO
O TYPE OF JOB:
R•C X New Installation
—Alteration/Addition/Repair
Revised 4/01H2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF SYSTEM: TYPE OF BUILDING:
®HEATING fkRESIDENTIAL
®A/C ❑ COMMERCIAL
®VENTILATION 0 INDUSTRIAL
HEATING
0 STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC UWARM AIR ❑]UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
Magic Pak M/N 51HWEMA 2 , Armstrong
GROSS HEATING CAPACITY(LN'PUT—BTUH)51 ,000 NET RATING(OUTPUT—BTUH) 40,000
TYPE OF FUEL
❑ OIL—GPM OIL TANK LOCATION:❑ INSIDE❑ OUTSIDE CAPACITY
5d GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF P e r
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) P 1 a n s
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) &
Specs
TONNAGE 2 COOLING CAPACITY(BTUH) 24,000
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
303755 S-1 CT
CONTRACTORS LICENSE NO. STATE
/ r
SIGNATURE OF APPLICANT DATE
.5 " a d s
DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT
Application is hereby:
TOWN OF SOUTH WINDSOR PERMIT#
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE
JW-21 20 644-2511 ext. 230 Bldg. Permit#
Date i3 or 3 ;L S f
Application must be printed or typed.
FEE SCHEDULE Location of Job:
F
Berry Patch 2S
$0-$1,000=$15.00 o. StreetOver$1,000= Lot No.
$15.00 per$1,000
or any fraction thereof Designation
Apt.No.
APPLICANT Thomas L. Jacquel c/o Allstate Fire Sprinkler, Inc.
APPLICANT ADDRESS P.O. Box 2350
Hartford, CT 06146
APPLICANT PHONE# (860) 246-7711
�C N SFq OWNER Berry Patch II Associates Limited Partnership
OWNER ADDRESS 6 Ex
ecutive Drive Suite 100
co� '� .
Farmington, Cr 06032
OWNER PHONE (860) .674-5641
►-� < = V
ESTIMATED COST$2,000.00
'r. IS THIS A CONTRACT COST? X Yes No
FEE ENCLOSED$ 3 0.0 0
r��s, O���V TYPE OF JOB:
OR•C
X New Installation
—_Alteration/Addition/Repair
Q—;—A A/nt innn�
APPLICATION FOR SPRINKLER PERMIT (Continued from reverse side)
TYPE OF BLILDL�G TYPE OF CONSTRUCTION 513 USE GROUP NO. OF STORIES
M RESIDENTIAL
❑ BUSINESS IS THIS APPLICATION ASSOCIATED WITH A
ZI ASSEMBLY BUILDING PERMIT APPLICATION? ❑ YES ❑NO
❑MERCANTILE
❑ EDUCATIONAL CURRENT USE AND OCCUPANCY
❑ INSTITUTIONAL
❑FACTORY FUTURE USE AND OCCUPANCY
❑ STORAGE
❑ GARAGE ENGINEERS NAME David R- Thanpsm PHONE(860) 246-7711
❑MIXED USE
(Other please specify) ADDRESS P.O. Box 2350
CTTy Hartford STATE CT ZIP 06146
KIND OF INSTALLATION
SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI)
ARE SPRINKLER HEADS ALTERED? 0 YES ❑NO
IF YES,CHECK ALL THAT APPLY: ®ADDED ❑DELETED ❑ALTERED
IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE)
3 PROFESSIONAL ENGINEER ❑INSURANCE COMPANY
WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI)
ARE PUMPS REQUIRED? Cl YES W NO IF YES,CHECK ALL THAT APPLY:
Cl FIRE ❑BOOSTER ❑ OTHER
ARE STANDPIPES PROVIDED? ❑YES ®NO IS A SPRINKLER SYSTEM PROVIDED? YES ❑NO
SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM
TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP N/A PSI
DESCRIPTION OF WORK
New fire sprinkler system in two bedroan unit
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNEC 1CUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
F10590 Fire Sprinkler CT
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
TOWN OF SOUTH WINDSOR
Application is hereby: PERMIT#( ��Q
?2004
BUILDING DEPARTMENT CL 1540 SULLIVAN AVENUE
2 644-2511 ext. 230 Bldg. Permit#
Dateg Inspec
Application must be printed or typed
FEE SCHEDULE Location of Job:
116 Berry Patch 2s
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000= '
$15.00 per$1,000
or any fraction thereof Tenant Designation
Apt.No.
APPLICANT J—Electric
APPLICANT ADDRESS 8 Sanrico Drive
Manchester, Cr 06040
APPLICANT PHONE# (860) 645-9891
------ --------
D N SFq OWNER Berry Patch II Associates Limited Partnership
OWNER ADDRESS 6 Executive Drive, Suite 100
Faimingtan, Cr 06032
OWNER PHONE (860) 674-5641
C ESTIMATED COST$ 2,700.00
V —
'� � IS THIS A CONTRACT COST? X Yes No
FEE ENCLOSED$ 45.00
4' III
SO O�� TYPE OF JOB:
R C X New Installation
Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
3 RESIDENTIAL BUILDING PERMIT APPLICATION? El YES ❑NO
❑ BUSINESS CURRENT USE AND OCCUPANCY
❑ ASSEMBLY
❑ MERCANTILE FUTURE USE AND OCCUPANCY Residence
❑ EDUCATIONAL
❑ INSTITUTIONAL -
❑FACTORY ENGINEER'S NAME ��' Engineering PHONE (860) 257-3968
❑ STORAGE 203 Briarwood Court
❑ GARAGE ADDRESS
❑MIXED USE
CITY Rocky Hill STATE Cr ZIP 06067
(Other please specify)
TYPE OF INSTALLATION/WHUNG METHOD NMC
SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS #2 Al
NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS
NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES ❑NO
NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8
NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23
NUMBER OF LIGHT FIXTURES 9 NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS 1
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
Interior wiring of apartment to include outlets, switches and their cover
plates. Wiring of appliances and HVAC unit. Install light fixtures.
Install 100 amp breaker panel.
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
123580 E-1 Cr
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE i%" `1/
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT
PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR C
BUILDING DEPARTMENT
LAPPROV 1540 SULLIVAN AVENUE644-2511 ext. 230 �lasatQ 6-- ing Inspe r
Application must be printed or typed
FEE SCHEDULE Location of Job:
116 Berry Patch 2_
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT Fahrenheit Mechanical Services Inc.
APPLICANT ADDRESS 56 Depot Street
Broad Brook, CI! 06016
APPLICANT PHONE# (860) 623-1991
Ow N S fq OWNER Berry Patch II Associates Limited Partnership
< OWNER ADDRESS 6 RKWutiye Drive, Suite 100
zo
Farmington, Cr 06032
OWNER PHONE (860) 674-5641
(17 ESTIMATED COST$ 5,000.00
IS THIS A CONTRACT COST? X Yes _No
t �G FEE ENCLOSED$_75.00
�` ��� TYPE OF JOB:
O R C X New Installation
_Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR PLUMBING PERIVIIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? ❑ YES ❑ NO
❑RESIDENTIAL
❑BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTII E FUTURE USE AND OCCUPANCY
❑EDUCATIONAL
❑ INSTITUTIONAL
❑FACTORY ENGINEER'S NAME PHONE
❑ STORAGE
❑ GARAGE ADDRESS
❑MIXED USE
CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4"
NO.OF TOILETS 1 STYLE Elongated NO.URINALS N/A STYLE N/A
NO.OF BATHTUBS NO.OF SHOWERS 1 NO.OF LAVATORIES 1
NO.OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3
AREA OF ROOF Back NO.OF CATCH BASINS N/A NO.OF FLOOR DRAINS 1
Kitchen
NO.OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel
ARE TOILET CONIPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES Of NO
SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR
SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer
SIZE OF WATER MAIN 2'1 SIZE OF WATER PIPING&RISER 3/4
Weil Mclain
WATER HEATER: TYPE Indirect MANUFACTURER P/US 120
DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLI_hS FOR A PERMIT TO PERFOR71 HE WOP K DESCRIBED AND IS'1'7--
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
P-1 00204480 P-1 Cr
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE ��- 9. Y