HomeMy WebLinkAbout114 CLINTON DR Revised 4/0IIi2UU2
Y �l
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby:
BUILDING DEPARTMENT
APPR VE 1540 SULLIVAN AVENUE
Bldg.Permit#
i� 644-2511 ext. 230
pate Building Inspector
Application must be printed or typed
FEE SCHEDULE F:Tenant
/ / /� Location of Job:
$0-$1,000=$15.00 Street Lot No.
Over$1,000$15.00 per$1,000
or any fraction thereof gnation Apt.No.
APPLICANT i lZeS o a t h
APPLICANT ADDRE S t f r.? /41e,, P., Po "3,,e3V Y
L T oG 16 -
APPLICANT PHONE#
OW N SF OWNER
q< OWNER ADDRESS �y L/:��.� /�,.VC
OWNER PHONE 9? '3i1
C ESTIMATED COST$
} IS THIS A CONTRACT COST? Yes _No
FEE ENCLOSED$
1���S - ��� TYPE OF JOB:
OR'C New Installation
X Alteration/Addition/Repair
1
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
❑HEATING RESIDENTIAL
❑A/C ❑COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
❑OIL--GPM OIL TANK LOCATION:❑ INSIDE❑OUTSIDE CAPACITY
GAS—INPUT LPG TANK CAPACITY 10—5 ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK 5 f tve1 //.�p,P f..�f, clbep�<ry C.,«t f.ers
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
ff76. 03yy6Yr- G ( G CT
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE ! Z
RESOURCE
Date:
To: Code Official V' .1)Sc ,--
I, Michael Santaw do give Gepald Bannock, Michele Janota, Shane Driscoll, Sam Bean,
Debra Wolfenson, Jason Malachowski, Christopher Lehnow, Craig Rossetti and/or
Harold Robinson of Energy Resource by Superior permission to use my license to obtain
a permit. n
The location of the work is /`� �" t�^ [�� ✓2
Thank you,
Michael Santaw
STATE OF CONNECTI(VT
HF—AVTING,PIPING&COOLING LIMITED CONTRACTOR �
MICHAEL P SANTAW 4 " acim.B
447 MILL ST �"r-MONE E "�
1, a .euc:
SOUTHINGi'Oiti,CT 064's9 7 Do";
-mow.:" + e>
LIC./REG NO. EFFECTIVE EXPIRES �IAWm 21�'t5
H1G.0394641_G 09/0l/2011 OS/31/2012 = 4
Swnwwrm CtIA,
SIGNED
1457 Meriden-Waterbury Road•Milldale(Rte.322,Southington),CT 06467 • (860)620-1500 • Toll Free:(866)926- • Fax:(860)620-1501
WWW. .com • Mailing Address: P.O.Box 348• Milldale,CT 06467-0348
- APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT
1ao i s6
APP O 1540 SULLIVAN AVENUE
Bldg. Permit#
644-2511 ext. 230
Date Building Inspecto
Application must be printed or typed
FEE SCHEDULE
Location of Job:
/�
$0-$1,000=$15.00 �/y �✓/ �N �� ��r�`'t�
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT J -et)S' O 1
A/PP�ICAN//T ADDRESS 136 It Ye 5'
APPLICANT'S PHONE #
OWNER A�-A Orr y E' .SaSr,i i'?c»—sc,.�!
q 0 se q� OWNER AD RESS /lc f C�p /�•rjaq j'•!/C,
OWNER PHONE
ESTIMATED COST$ yam, le; 2 s. ely
IS THIS A CONTRACT COST? Yes (VNo
FEE ENCLOSED$ /6Y.)' G O
TYPE OF JOB:
�SOR•CO New Installation �00
Alteration/Addition/Repair \�
Revised 03/05/10
APPLICATION FOR IIVAC PERMIT(Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
❑ HEATING D-RESIDENTIAL
KKA/C ❑ COMMERCIAL
P,-<E'NTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP.OUTSIDE °F INSIDE °F DIFFERENCE °F
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY
❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE °F INSIDE °F DIFFERENCE °F
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
me a/a 0 �/-'s-'7/q, /Uo 0
TONNAGE ? COOLING CAPACITY(BTUH) 3e, OGv
VENTILATION
DESCRIBE ALL AIR HANDLING EQ MENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) ,
d 1C
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY A/PPLLIICATION) J J
FUJWTHERPESCRIPTION OF WORK 'r �v N �tqr�Ya�'� !� ��'f�• -+G�ily
1 J
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
30 3-;;,g2 1151
CONTRACTORS LICENSE NO. TYPE / STATE
SIGNATURE OF APPLICAN DATE / `�
9 Load Short Form Job: borgen
wrl htsoft Date: Jan 24,2012
• Entire House By:
Andrews Oil Co.
Project • •
For: Anthony&Susan Borgen
114 Clinton Drive, South Windsor, ct 06074
Phone: 860-644-9217
Design Information
Htg Clg Infiltration
Outside db(°F) 8 88 Method Simplified
Inside db (°F) 68 75 Construction quality Average
Design TD (°F) 60 13 Fireplaces 1 (Average)
Daily range - M
Inside humidity (%) 50 50
Moisture difference (gr/lb) 45 22
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Model Cond
GAMA ID Coil
ARI ref no.
Efficiency 80 AFUE Efficiency 0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Low output baseboard 500 Btuh/ft Total cooling 0 Btuh
Total low baseboard 0 ft Actual air flow 1422 cfm
High output baseboard 700 Btuh/ft Air flow factor 0.044 cfm/Btuh
Total high baseboard 0 ft Static pressure 0.00 in H2O
Space thermostat Load sensible heat ratio 0.77
ROOM NAME Area Htg load Clg load Baseboard (ft) Clg AVF
(ft2) (Btuh) (Btuh) Low High (cfm)
bedroom 1 181 0 3963 0 0 174
mst bedroom 181 0 2397 0 0 105
bedroom2 107 0 2530 0 0 111
office 95 0 2503 0 0 110
kitchen 224 0 9296 0 0 409
dining room 129 0 3407 0 0 150
living room 358 0 8231 0 0 362
Entire House d 1275 0 32327 0 0 1422
Other equip loads 24796 5372
Equip. @ 0.93 RSM 35060
Latent cooling 11232
TOTALS 1275 24796 46293 0 0 1422
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft Right-Suite—Universal 7.0.14 RSU03006 2012-Jan-24 14 47.0E
f�Cp C\Documents and Settings\User\My Documents\Wnghtsoft HVAC\borgen rup Calc=MJB Orientation= Page 1
.�. 9 Building Analysis Job: borgen
wri htsoft 9 Y Date: Jan 24,2012
Entire House By:
Andrews Oil Co.
Pro*ect Information
For: Anthony& Susan Borgen
114 Clinton Drive, South Windsor, ct 06074
Phone: 860-644-9217
Design Conditions
Location: Indoor: Heating Cooling
Windsor Locks Bradley Field, CT, US Indoor temperature(°F) 68 75
Elevation: 180 ft Design TD (°F) 60 13
Latitude: 42°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 44.6 22.5
Dry bulb (°F) 8 88 Infiltration:
Daily range T - 21 ( M ) Method Simplified
Wet bulb (° ) - 71 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average)
Heatin
•
Component Btuh/ft2 Btuh %of load
Walls 0.0 0 0.0
Glazing 0.0 0 0.0
Doors 0.0 0 0.0
Ceilings 0.0 0 0.0
Floors 0.0 0 0.0
Infiltration 0.0 0 0.0
Ducts 0 0.0
Piping 0 0.0
Humidification 0 0.0
Ventilation 24796 100.0
Adjustments 0
Total 24796 100.0
Component Btuh/ft2 Btuh %of load
Waft
Walls 1.0 1076 2.9 Ver"Mb^
Glazing 30.2 7644 20.3 ,�,
Doors 8.7 288 0.8
Ceilings 1.0 1334 3.5
Floors 0.0 0 0.0
Infiltration 0.4 595 1.6 °"-
Ducts 4560 12.1
Ventilation 5372 14.3
Internal gains 16830 44.6
Blower 0 0.0 Duds
Adjustments 0
Total 37699 100.0
Overall U-value= 0.088 Btuh/ftZ-°F
Data entries checked.
",- -fia- wrightsoft Right-Suitew Universal 7.0.14 RSU03006 2012-Jan-24 14:47:06
AM CADoaxnents and Settings\UsenMy Documents\Wnghtsoft HVAClborgen rup Calc=mio orientation= Pagel
Component Constructions Job: bourn
wrightsoftx P ate: Jan 24,2012
Entire House By:
Andrews Oil Co.
Project Information
For: Anthony&Susan Borgen
114 Clinton Drive, South Windsor, ct 06074
Phone: 860-644-9217
Design Conditions
Location: Indoor: Heating Cooling
Windsor Locks Bradley Field, CT, US Indoor temperature(OF) 68 75
Elevation: 180 ft Design TD (OF) 60 13
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(grAb) 44.6 22.5
Dry bulb(OF)°F 8 88 Infiltration:
Daily range °F) - 21 ( M ) Method Simplified
Wet bulb(OF) - 71 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Ctg HTM Gain
tr Bk*W--'F rr-'Flaw MAW Btuh Bkow Btuh
Walls
12E-Osw:Fan wall,wd md,1/2"wood shth,r-19 cav ins,1/2" ne 450 0.068 19.0 0.00 0 1.02 458
gypsum board int fish,2"x4"wood frm se 86 0.068 19.0 0.00 0 1.02 87
sw 307 0.068 19.0 0.00 0 1.02 312
nw 215 0.068 19.0 0.00 0 1.02 219
all 1058 0.068 19.0 0.00 0 1.02 1076
Partitions
(none)
Windows
4A1-2ov:2 glazing,cir low-e outr,argon gas,insulated vinyl fan ne 136 0.470 0.0 0.00 0 27.2 3688
mat,clr innr,1/4"gap,1/8"thk;50%drapes,medium;50% se 21 0.470 0.0 0.00 0 33.6 689
outdoor insect screen;foreground=green grass(0.23) sw 58 0.470 0.0 0.00 0 33.6 1959
sw 39 0.470 0.0 0.00 0 33.6 1308
all 253 0.470 0.0 0.00 0 30.2 7644
Doors
1110:Door,wd pnI type,mtl star star ne 33 0.360 1.0 0.00 0 8.66 288
Ceilings
16B-44aad:Attic ceiling,asphalt shingles roof mat,r-2 roof ins,r-44 1276 0.022 44.0 0.00 0 1.05 1334
ceil ins,1/2"gypsum board int fnsh
Floors
(none)
C -P�1- wrig@7tsoft- Right-Sude'UnMmv.17.0.14 RSU03000 2012-Jan-24 14:47:07
cmoanne a and Settings\U•erwy Doaunen %Wrightson HVACV vensup Calc-WO Orlent•tlon Page 1
° Pro1ect Summary ry Job: borgen
Wrightsof Date: Jan 24,2012
Enure House By:
Andrews Oil Co.
Project • •
For. Anthony&Susan Borgen
114 Clinton Drive South Windsor, ct 06074
Phone: 860-644-§217
Notes:
Design Information
Weather: Windsor Locks Bradley Field, CT, US
Winter Design Conditions Summer Design Conditions
Outside db 8 OF Outside db 88 OF
Inside db 68 OF Inside db 75 OF
Design TD 60 OF Design TD 13 OF
Daily range M
Relative humidity 50 %
Moisture difference 22 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 0 Btuh Structure 27767 Btuh
Ducts 0 Btuh Ducts 4560 Btuh
Central vent(378 cfm) 24796 Btuh Central vent(378 cfm) 5372 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 24796 Btuh Use manufacturer's data n
Rate/swing multiplier 0.93
Infiltration Equipment sensible load 35060 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 4835 Btuh
Ducts 660 Btuh
Heating Cooling Central vent(378 cfm) 5737 Btuh
Area(ft') D 127b Equipment latent load 11232 Btuh
Volume(ft') 0 10919
Air changes/hour 0.61 0.23 Equipment total load 46293 Btuh
Equiv. AVF(cfm) 0 42 Req.total capacity at 0.70 SHR 4.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
GAMA ID Coil
ARI ref no.
Efficiency 80 AFUE Efficiency 0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Low output baseboard 0 ft Total cooling 1422 cfm
Total low baseboard 700 Btuh/ft Actual air flow 0.044 cfm/Btuh
High output baseboard 0 ft Air flow factor 0.00 in H2O
Total high baseboard Static pressure 0.77
Space thermostat Load sensible heat ratio
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wr19te1t0of1:' RWK-Sufte—Universal 7.0.14 RSU03006 2012-Jan-24 14:47:07
Al.c.1. Mocu nenb and SettftsWserWy Docunwt%Vfthtsofl HVACl xnw.nrp Cak-MJS Onentaffon` Page 1
Job: borWn
- wrightsoft' AED Assessment Date: Jan 24,2012
Entice House By:
Andrews Oil Co.
Project Information
For: Anthony&Susan Borgen
114 Clinton Drive, South Windsor,ct 06074
Phone: 860-W-9217
Design Conditions
Location: Indoor: Heating Cooling
Windsor Locks Bradley Field, CT, US Indoor temperature(OF) 68 75
Elevation: 180 ft Design TD(OF) 60 13
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 44.6 22.5
Dry bulb(OF) 8 88 Infiltration:
Daily range °F) - 21 ( M )
Wet bulb(0 ) - 71
Wind speed(mph) 15.0 7.5
Test for • - • Exposure Diversity
Hourly Glazing Load
11,00
10,00
9,00
t
8,00
m 7,00
$ 6,00
5,00
4,00
3,00
2,0
1,00
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
,e Hourty / Average / AED limd
Maximum hourly glazing load exceeds average by 28.9%.
House has adequate exposure diversity(AED), based on AED limit of 30%.
AED excursion: 0 Btuh
C Ad- wriaht exIt` Right-Suite"'Universal 7.0.14 RSU03006 2012Jan-24 14:47:07
AM C:1Doasnerft and S.M1ng.1AJ .My Docum ft\Wright ft HVACtb.W.rtp Cak-Mde Orientation= Page 1
-+ wrightsoft Right-A)Worksheet Job: bMen
Entire House Byte: Jan 24,2012
Andrews Oil Co.
1 Room name Entire House bedroom 1
2 Exposed wall 159.4 ft 27.0 ft
3 Ceding height 8.6 ft d 8.0 ft Cool only
4 Room dimensions 13.3 x 13.6 ft
5 Room area 1275.4 ft° 181.3 f?
Ty Construction U-value Or HTM Area (ft-) Load Area (W) Load
number (Btuh/ft;`F) (Btuh/ft1) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 V)1 12E-Osw 0.068 ne 0.00 1.02 619 450 0 458 110 103 0 1D4
GG 4A1-2ov 0.470 ne 0.00 27.22 136 0 0 3688 7 0 0 197
1110 0.360 ne 0.00 8.66 33 33 0 288 0 0 0 0
Vdl 12E-Osw 0.068 se 0.00 1.02 106 86 0 87 106 86 0 87
11 , G, 4A1-2ov 0.470 se 0.00 33.63 21 0 0 689 21 0 0 689
V)I 12E-Osw 0.068 sw 0.00 1.02 404 307 0 312 136 116 0 117
r;_CG 4A1-2ov 0.470 sw 0.00 33.63 58 0 0 1959 21 0 0 689
4A1-2ovd 0.470 sw 0.00 33.63 39 0 0 1308 0 0 0 0
W 12E-Osw 0.068 nw 0.00 1.02 215 215 0 219 0 0 0 0
C 1613-44ad 0.022 - 0.D0 1.05 1276 1276 0 1334 181 181 0 190
6 c)AED excursion 0 -267
Envelope losstgain 0 10342 0 1818
12 a) Infiltration 0 595 0 156
b Room ventilation 0 0 0 0
13 Internal gains: Occupants C 230 21 4830 1 230
Appliances Q 1200 10 1200D 1 1200
Subtotal(lines 6 to 13) 0 27767 0 3404
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 0 27767 0 3404
15 Duct loads 16% 0 4560 0% 16% 01 559
Total mom load D 32327 0 3963
Lov4High Baseboard/Cool Air 01 0 1422 1 0 0 174
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
+}+ wr�9x,tsorc- Rlght-Suite"'Unlversa17.0.14 RSU03006 2012-Jan-2414:47:07
'���` C:1Do=rw is and Setting3vise"Documerhimightsoft WACftrgen.rup Calc-WS Orientation Page 1
+ wrightsofr Right-J®Worksheet Job: boMen
Entire House Date: Jan 24,2012
Andrews Oil Co. By:
1 Room name mst bedroom bedroom2
2 Exposed wall 27.7 ft 10.7 ft
3 Ceiling height 8.0 It cool only 8.0 ft cool only
4 Room dimensions 10.7 x 17.0 ft 10.7 x 10.0 It
5 Room area 181.2 fe 106.6 ft=
Ty Construction U-value Or HTM Area Load Area Load
number (Btuhlft'---F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 12E-Osw 0.068 ne 0.00 1.02 87 80 0 81 85 65 0 66
{L—_�C 4A1-2ov 0.470 ne 0.00 27.22 7 0 0 197 21 0 0 558
1110 0.360 no 0.00 8.66 0 0 0 0 0 0 0 0
12E-Osw 0.068 se 0.00 1.02 0 0 0 0 0 0 0 0
11 Y—G 4A1-2ov 0.470 se 0.00 33.63 0 0 0 0 0 0 0 0
Y+/ 12E-Osw 0.068 sw 0.00 1.02 0 0 0 0 0 0 0 0
I�—�G 4A1-2ov 0.470 sw 0.00 33.63 0 0 0 0 0 0 0 0
4A1-2ovd 0.470 sw 0.00 33.63 0 0 0 0 0 0 0 0
w 12E-Osw 0.068 nw 0.00 1.02 0 0 0 0 0 0 0 0
C 16B-44ad 0.022 - 0.00 1.05 181 181 0 190 107 107 0 112
6 c)AED excursion -108 -29
Envelope loss/gain 0 360 0 706
12 a
b) Infiltration 0 38 0 38
Room ventilation 0 0 0 0
13 Internal gains: Occupants Q 230 2 460 1 230
Appliances t? 1200 1 1200 1 1200
Subtotal pines 6 to 13) 0 2059 0 2174
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 0 2059 0 2174
15 Dud loads 0% 16% 0 338 0% 16% 0 357
-F1
F1Total room load 0 2397 0 2530
Lov4 fth Baseboard/Cool Air 0 0 397 0 0 111
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
+}r wr�vtitsoTt Right-Sufte"'Universal 7.0.14 RSU030D6 2012-Jan-2414:47:07
A&` C:1Doa rrwft and SettingsWserWly Doamrents\Wrightsoft WAC�borgen.rup Cale-MJ8 Orientation Page 2
- -wrightsoft' Right-J®Worksheet Job: borgen
Entire House Date: Jan 24,2012
By:
Andrews Oil Co.
1 Room name office kitchen
2 Exposed wall 19.5 ft 21.5 ft
3 Ceding height 8.0 ft cod only 8.0 ft cool only
4 Room dimensions 9.5 x 10.0 ft 10.4 x 21.5 ft
5 Room area 95.0 iN 224.5 ft'
Ty I Construction U-value Or HTM Area (tt') Load Area (ftV) Load
number (Btuhlft;'F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
6 %1 12E-Osw 0.068 ne 0.00 1.02 76 56 0 56 0 0 0 0
EL _G 4A1-2ov 0.470 ne 0.00 27.22 21 0 0 558 0 0 0 0
1110 0.360 no 0.D0 8.66 0 0 0 0 0 0 0 0
12E-Osw 0.068 se 0.00 1.02 0 0 0 0 0 0 0 0
11 T--G 4A1-2ov 0.470 se 0.00 33.63 0 0 0 0 0 0 0 0
1qJ 12E-Osw D.068 sw 0.00 1.02 0 0 0 0 172 123 0 125
rE-GG 4A1-2ov 0.470 sw 0.00 33.63 0 0 0 0 10 0 0 328
4A1-2ovd 0.470 sw 0.00 33.63 0 0 0 0 39 0 0 1308
W 12E-Osw 0.068 nw 0.00 1.02 0 0 0 0 0 0 0 0
C 16B-44ad 0.022 - 0.00 1.05 95 95 0 99 225 225 0 235
B c)AED excursion -28 193
Envelope loss/gain 0 686 0 2189
12 a) Infiltration 0 34 0 76
b Room ventilation 0 0 0 0
13 Internal gains: Occupants Q 230 1 230 4 920
Appliances Q 1200 1 1 1200 4 4800
Subtotal(lines 6 to 13) 0 2150 0 -7985
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 0 2150 0 7985
15 Duct bade 0%. 16% 0 353 0% 16% 0 1311
Total room load 0 2503 0 9296
LowlHigh Baseboard/Cod Air 1 0 0 110 0 0 409
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
f}+ wr�g�+c=ort Right-Suitev"Universal 7.0.14 RSU03006 2012Jan-2414:47:07
Moaanents and Settingz%UserWly Do uments\Wrightsoft HVAClborgen.rup Cale-MJ8 Orientation Page 3
- wrightsoft Ri ht-JO Worksheet Job: borgen
Entire Hbuse Dace: Jan 24,2012
By:
Andrews Oil Co.
1 Room name dining mom living room
2 Exposed wall 22.8 ft 30.3 ft
3 Ceding height 8.0 ft cool only 10.0 ft cool only
4 Room dimensions 12.5 x 10.3 ft 13.3 x 27.0 ft
5 Room area 129.1 ft' 357.8 ft'
Ty I Construction U-value Or HTM Area (ft) Load Area (" Load
number (Btuh/V--'F) (B or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 1qJ 12E-Osw 0.068 ne 0.00 1.02 0 0 0 0 261 148 0 150
EL-_-pG 4A1-2ov 0.470 ne D.DO 27.22 0 0 0 0 80 0 0 2177
1110 0.360 ne 0.00 8.66 0 0 0 0 33 33 0 288
V�I 12E-Osw 0.068 se 0.00 1.02 0 0 0 0 0 0 0 0
11 --G 4A1-2ov 0.470 se 0.00 33.63 0 0 0 0 0 0 0 0
gyp! 12E-Osw 0.068 sw 0.00 1.02 96 68 0 69 0 0 0 0
1��G 4AII-2ov D.470 sw 0.00 33.63 28 0 0 942 0 0 0 0
4A1-2ovd 0.470 sw 0.DO 33.63 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 nw 0.00 1.02 83 83 0 84 133 133 .0 135
C 16B-44ad 0.022 - 0.00 1.05 129 129 0 135 358 358 0 374
6 c)AED excursion 237 -8
Envelope IDss/gain 0 1467 0 3116
12 a) Infiltration 0 79 0 174
b Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 6 1380 6 1380
Appliances C 1200 0 1 01 2 1 2400
Subtotal Pines 6 to 13) 0 2926 0 7070
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 0 2926 0 7070
15 Duct loads 1 0% 16% D 481 0%1 16% 0 1161
Total room load 0 3407 0 8231
LowlHigh Baseboard ICool Air 0 0 150 0 0 362
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
r{+- w�rgr,csorr Right-Suite^'Universa17.0.14 RSU03OD6 2012-1an-24 14:47:07
��� C:1Doc merits end SettingsWser\My Doaments\Wrightsott HVAClborgen.rup Cale-W8 Orientation Page 4
APPLICATION FOR ELECTRICAL PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT
APPR V 1540 SULLIVAN AVENUE
644-2511 ext. 230 Bldg. Permit#
Date Building Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000= $15.00
Over$1,000= I Street No. Street Lot No.
$15.00 per$1,000 _
or any fraction thereof Tenant Designation Apt.No.
APPLICANT PQ- rQ2.
APPLICANT ADDRESS 12
APPLICANT'S PHONE# _Qejb�) $3tC 5/3QY
OWN OWNER
q 3fq< OWNER ADDRESS
(0) 4W OWNER PHONE
ESTIMATED COST$ /IdV
IS THIS A CONTRACT COST? Yes No
.� FEE ENCLOSED$
TYPE OF JOB: *I D f O
C0 New Installation
Alteration/Addition/Repair
Revised 03/05/10
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? ❑ YES ANO
RESIDENTIAL CURRENT USE AND OCCUPANCY
❑ BUSINESS
❑ ASSEMBLY FUTURE USE AND OCCUPANCY
❑ EDUCATIONAL
❑ INSTITUTIONAL ENGINEER'S NAME PHONE
❑ FACTORY
❑ STORAGE ADDRESS
❑ GARAGE
❑ MIXED USE CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD Kvq C-r t,y-,2 - j r c,
SIZE OF SERVICE SIZE OF MAIN CONDUCTORS
NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS
NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO
NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR-
MANCE OF SUCH WORK
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE ��
APPLICATION FOR ELECTRICAL PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT y /o a
PR�y 1540 SULLIVAN AVENUE Bldg. #
644-2511 ext. 230
Date Bui 'ng Inspector
Application must be printed or typed
FEE SCHEDULE
Location of Job:
$041,000=$15.00 Jay ti 240
C R�yE
Over$1,000 — Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt. No.
APPLICANT
APPLICANT ADDRESS 2 �2
F; c,<d Ct. d 66 z-
APPLICANT'S PHONE# (�)6 U — 'f,
OWNER
OWN SF
•( q< OWNER ADDRESS
C OWNER PHONE C,?6 G) 6' c f c- 9 Z/ 7
ESTIMATED COST$ IJ700
C �
U IS THIS A CONTRACT COST? Yes No
FEE ENCLOSED $ 3G
TYPE OF JOB:
$ •CO New Installation C
OR C �$ Ic� q
Alteration/Addition/Repair
Revised 03/05/10
t APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TITE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? ❑ YES YNO
RESIDENTIAL CURRENT USE AND OCCUPANCY
❑ BUSINESS
❑ ASSEMBLY FUTURE USE AND OCCUPANCY
❑ EDUCATIONAL
❑ INSTITUTIONAL ENGINEER'S NAME PHONE
❑ FACTORY
❑ STORAGE ADDRESS
❑ GARAGE
❑ MIXED USE CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD 10o AM YJ �E 2 U I C f C�a
SIZE OF SERVICE 4!Q a A111 2 SIZE OF MAIN CONDUCTORS�� /9G
NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS
NUMBERS OF PANELS f NUMBERS OF DISCONNECTS REQUIRED? ❑ YES 4/NO
NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR-
MANCE OF SUCH WORK
CONTRACTORS LICENSE 10 TYPE `STATE
SIGNATURE OF APPLICANT DATE
BUILDING PERMIT
STATE OF CONNkMCUT
WORKERS'COMPENSATION COMMISSION
Building Permit Affidavit for Property Owners or Sole Proprietors
(Conn.Gen.Stat.§31-286b)
Pioperty located at
In the town of�Co 7� C(j, K,�`C,y Cf.
�r
Name of building permit applicant:
Please check one:
1._1 am the owner of the above property.
2.--Z1 am the sole proprietor of a business.
2A.Name of business fL �,F F �«, cE C �c
2B.Federal Employer Identification Number ff IN) O t1 g - 7 e
....................................................................................................................
Pursuant to§31-286b,"a properly owner or sole proprietor[who]intends to act as a general
contractor or principal employer"may provide either a certificate of workers'compensation
insurance or a"sworn notarized affidavit... stating that he will require proof of worker.?
compensation insurance for all those employed on the job site in accordance with this chapter."
Please check one:
1._I do not intend to act as a general contractor or principal employer.
[Sign and stop here]
Signature of applicant
2._I intend to act as a general contractor or principal employer.Applicant must either
provide a certificate of workers'compensation insurance or sign the affidavit
below.
....................................................................................................................
Affidavit
I hereby swear and attest that I will require proof of workers'compensation insurance for every
contractor,subcontractor,or other worker before he/she engages in work on the above property in
accordance with the Workers'Compensation Act(Chapter 568).
I understand that pursuant to§31-275 C.G.S.,officers of a corporation and partners in a
partnership may elect to be excluded from coverage by filing a waiver with the appropriate
District Office;and that a sole proprietor of a business is not required to'have coverage unless he
files his intent to accept coverage.
Signature of applicant
Subscribed and sworn to before me this day of ,200 .
(Notary Public!Commissioner of the Superior Court)
1
LO`t' 35 LOT 36 ,_GT 37
9�o 170.00 _o
LOT 34 LCT 32
5
1
t;
4i
1tDlNVR `7S O��"
AJNTc
PROPERTY OF
V
NO. CLINTON DRIVE SOUTH WINDSOR, CONN.
Being Lot No. 33 on map entitled "Map of OAK RIDGE ESTATES
Foste ' Scale : 1 " - 40' Sept . 5, 1965--
H a yde n Lr�i Biro T�cZ`pC �'
dod t
9 d ad
dft
AJ
HAYDEN L. dRISWOLD C. E.
r;
a
oar
r,y.
'4'
10 Ulf BWUL46 aw, town � i�M 1YW�i0►
Thia-TtM d that this al" eM Weelfleatbns or%trs.
c^pies of the propoa.sd ba{Ning tY rt
erected at r
I
street
tegetiler wi a mendments stated In 312016etlsn *no
Illed with plan and I agree to comply with all zoning,
Building and state laws and such orders as shall be
issued by the Building Department during pandeney
Of this application and final IssuarM of a. bulldln&
Permit.
xSigned
This plan is approved Subic" to the Condition that
orders and ordinances rtlgulatlaill building shall be
corr:6sisd with.
conOtticnally Approved Qnaa filed with
Building Inspectorlots
'"'�—� fgR vim►V v--�J� i
CA /VNI:
CERTIFICATION OF ZONING COMPLIANCE
Proposed bullding(s), u*a)OrWor structure(:)
as shown on With i I s) to be in
conformance7
mouth Windsor
regulations. Variances 4W SWial exceptions
may apply.
Date1� r"
t
(o 1
71
APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT
APPR 1540 SULLIVAN AVENUE Bldg.
U 0�3
Bldg.Permit#
1 . 6 ! V 644-2511 ext. 230
Date Building Inspecto
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 l y G L p/t, ✓ z
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT o K^' G�2 �1/�i 2G� 7' to tS
APPLICANT ADDRESS !`/S -7 Z z
0.4cf 11"G7
APPLICANT'S PHONE# 2v3 5� 3 —7 — 3 Yo
OWNER
0%OWN SFq< OWNER ADDRESS / `/ G L ��1� v /liL. ✓'�
X
C
OWNER PHONE S G 6 v(K
CESTIMATED COST$
IS THIS A CONTRACT COST? Yes No
FEE ENCLOSED$
TYPE OF JOB:
SOR,coy' ✓New Installation
Alteration/Addition/Repair Q� l�-
Revised 03/05/10
APPLICATION FOR HVAC PERMIT(Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
J-HEATING RESIDENTIAL
❑ AjC ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
�i/N�l /i✓1+ /l'�1 'F -"r�t�C.�J �/2 L�L/r(L �C LO/� /FI ✓niv'7�iJ G� S/� 7
GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH)
TYPE OF FUEL
❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY
GAS-INPUT LPG TANK CAPACITY t 20 ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
GrwoZ7r/ �/ G 7/-
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE V V
L t_GT 3 6 `OT 37
9C a 170.00 ,?
LOT 34 407 33 LOT 32
.J
1�
LAO
170.00
FOR BUILDING pURpOSES ONLY
PROPERTY OF rq .
NO. OLINTON DRIVE SOUTH WINDSOR, CONN .
Being Lot No. 33 on map entitled "Map of OAK RIDGE ESTATES
Foster St. South Windsor, C♦nn. Scale : 1 " - 40' Sept . 5, 1965
Hayden L. Griswold C. E. Sheet3"
Scale 1 " = 40'
HAYDEN L. GRISWOLD C. E.
Electric # APPLICATION FOR BUILDING PERMIT
Plumbin D 114 Clinton DRive
HVAC# run J(JA73_ 76 110 n m m n S Date: 7f
Sprinkler# Estimated Cost $. 1,9S 3 —
FINAL APPROJO M Permit Fee $ 30
Building rre �..�OA COMPLETE RED BOXED AREAS Occupancy Fee $
Engineering
Affidavit TYPE OF PRINT ONLY Eng. Insp. Fee $
Appr.forCO. SIGN ON REVERSE SIDE A Total Fee $
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ ��
The undersigned hereby applies to do work according to the following:
Applicant -J a H ti o A A Location of Work <<4/ �� *-?" 04 Lot No.
Applicant's Address /r'S r 12'7- 3Z Z Tel # V6' -G Z" -/Sc,-'
Town Zip
Owner Architect
Owner's Address ley G 4"- Architect's Address
-S 11 L._74 -e n.7s.1 e-% Zip O G"7y Zip
Sq. Ft.New Area: 1 st FI. 2nd FI. 3rd Fl. Total New Area
Purpose of this permit 5— /Z !i ILL ,����.ml f T�)�"ti ap' 1e40`' A
e-�,��'fA 1.115 Lim't f d.-Ac fry
City Water❑ Well 0 Septic System ❑ Sewer❑
oup
Ins: HO ST�",/
rt. Area Basement Garage
Approved byDate f- b 9 Use Group Construction Type
Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this b� g and its use is allowed.
Signed - --
I hereby apply for a Certificate of Wc.pancy for the work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
PA 17-176
AND
CGS
Electric # APPLICATION FOR BUILDING PERMIT
Plumbing#
HVAC# 1/y C�irr�t�n lDr�y e Date: ^/ : -
' Sprinkler# Estimated Cost $ /
FINAL APPROV LS
Building '^ ' J COMPLETE RED BOXED AREAS Permit Fee $ '—
Occupancy Fee $
Engineering Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee $
Appr.forCO. SIGN ON REVERSE SIDE
Total Fee $
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ - y
The undersigned hereby applies to do work according to the following:
Applicant - L� ✓v Location of Work Lot No.
I
Applicant's Address _ A2 t+lus r'I•4 Tel #
Town 1v 0 uQ"a c- Zip(Jb �2 7 Lic.# S L( 3 S
Owner h S P 1 Architect
Owner's Address I `7 �' '� '�~ Q/' Architect's Address
Zip 0& 0 ki Zip
Sq. Ft. New Area: 1 st FI. 2nd Fl. 3rd FI. Total New Area
Purpose of this permit f r+ zu ►'�_1-Ct +
City Water J Well J Septic System J Sewer J �o46o7;Z7
Ins: HO SP Area Basement Garage
Approved by Date Use Group Construction Type
Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required t
distances from all other zones and is located in which this building and itsuse is allowed.
Signed d ��7✓ C V L � l
I hereby apply for a Certificate of Occupancy for the work described in this
application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
INSPECTION FIELD SHEET 03/30/23
Printed by Middleton, Morgan 16 20 50
INSPECTION: 104752 FINAL PERMIT:
STATUS
APPLICATION: 201800727
LOC: 114 CLINTON DRIVE
SOUTH WINDSOR
PROPERTY ID: 21300114
OWNER: BORGEN SUSAN A
CONTRACTOR:
REQUEST BY:
PROJ DESC: TEAR ROOF, ICE AND WATER, RIDGE VENT, COPPER FLASHING,
WORK ORDER:
INSPECTOR: WS-B RESULT: PASS
REQUESTED: PRIORITY:
SCHEDULED: COMPLETED: 03/30/23
UNPAID FEES 00 Date Time
MILEAGE: 00 TIME: TRAVEL ONSITE
COMMENTS:
INSPECTED BY VALERIE MUSZYNKSI TO CLOSE OUT OLD PERMIT
1800250 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 05/23/2018
GIS ID:21300114 FEE: 180.00
MUNIS APPLICATION# 201800727 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ALCRAFT INC. ADDRESS: 114 CLINTON DRIVE
ADDRESS: 605 WASHINGTON AVENUE OWNER: BORGEN SUSAN A
NORTH HAVEN,CT 06473 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: TEAR ROOF,ICE AND WATER,RIDGE VENT,COPPER FLASHING,
ARCHITECTURAL SHINGLES.20 SQUARES.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
5/23/2018 I0:33 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
11000005 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 01/06/11
GIS ID:21300114 FEE: 30.00
MUNIS APPLICATION# 201100017 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE
ADDRESS: P.O.BOX 348 OWNER: BORGEN ANTHONY W&SUSAN A
MILLDALE,CT 06467 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: SET 120 GAL:PROPANE TANK AND RUN A COPPER GAS LINE INTO THE
BASEMENT FIREPLACE.
r
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
1/24/2011 3:45 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
11000005 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 01/06/11
GIS ID:21300114 FEE: 30.00
MUNIS APPLICATION# 201100017 BUILDING DESCRIPTION:
APPLICANT,;' ., LOCATION
NAME: ENERGY RESOURCE ADDRESS: I 14'CLINTON DRIVE
ADDRESS: 1457 RT 322 OWNER: BORGEN ANTHONY W&SUSAN A
MILLDALE,CT 06467 f 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: SET 120 GAL.PROPANE TANK AND RUN A COPPER GAS LINE INTO THE
BASEMENT FIREPLACE.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
',f,I",
1/6/20I 1 2:34 PM_ _ THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1200150 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 04/19/12
GIS ID:21300114 FEE: 150.00
MUNIS APPLICATION# 201200424 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ANDREWS OIL CO. ADDRESS: 114 CLINTON DRIVE
ADDRESS: 136 RYE STREET OWNER: BORGEN ANTHONY W&SUSAN A
SOUTH WINDSOR,CT 06074 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: INSTALLING CENTRAL A/C.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: B G OFFICIAL
4/19/2012 12:45 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1100003 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 01/06/11
GIS ID:21300114 " FEE: 15.00
MUNIS APPLIC1TIt0N#`201100017 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE
ADDRESS:. 1457 RT.322 OWNER: BORGEN ANTHONY W&SUSAN A
MILLDALE,CT 06467 = 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: SET 120 GAL.PROPANE TANK AND RUN A COPPER GAS LINE INTO THE
BASEMENT FIREPLACE.
SPECIAL CONDITIONS:
ALL WORK TO BE'DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
i i
1100003 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 01/06/11
GIS ID:21300114 FEE: 15.00
MUNIS APPLICATION# 201100017 BUILDING DESCRIPTION:
APPLICANT,. LOCATION
NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE
ADDRESS: P.O.BOX 348 OWNER: BORGEN ANTHONY W&SUSAN A
MILLDALE,CT 06467 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: SET 120 GAL.PROPANE TANK AND RUN A COPPER GAS LINE INTO THE
BASEMENT FIREPLACE.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
1/24/2011 3:45 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1200182 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 05/09/12
GIS ID:21300114 FEE: 15.00
MUNIS APPLICATION# 201200547 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE
ADDRESS: P.O. BOX 348 OWNER: BORGEN ANTHONY W&SUSAN A
MILLDALE,CT 06467 ` 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: INSTALL 100 GALLON PROPANE TANK,UNDERGROUND PIPING,AND
CONNECT TO EXISTING TANK.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
5/9/2012 11:40 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1200145 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER ELECTRICAL PERMIT
DATE: 05/09/12
GIS ID:21300114 FEE: 30.00
MUNIS APPLICATION# 201200547 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ELECTREX,LLC. ADDRESS: 114 CLINTON DRIVE
ADDRESS: 125 SOUTH STREET OWNER: BORGEN ANTHONY W&SUSAN A
VERNON ROCKVILLE,'CT 06066 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: INSTALL 100 GALLON PROPANE TANK,UNDERGROUND PIPING,AND
CONNECT TO EXISTING TANK.
INSTALL OF 8 KW GENERATOR WITH AUTOMATIC TRANSFER SWITCH.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS'APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
5/9/2012 I0:55 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1100103 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER ELECTRICAL PERMIT
DATE: 05/11/11
GIS ID: 21300114 FEE: 30.00
MUNIS APPLICATION# 201100415 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: TIM SWEETMAN ADDRESS: 114 CLINTON DRIVE
ADDRESS: 25 PARKER STREET OWNER: BORGEN ANTHONY W&SUSAN A
ENFIELD,CT 06082 114 CLINTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: 100 AMP SERVICE CHANGE.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
5/1 I/2011 2:19 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE