Loading...
HomeMy WebLinkAbout114 CLINTON DR Revised 4/0IIi2UU2 Y �l DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPR VE 1540 SULLIVAN AVENUE Bldg.Permit# i� 644-2511 ext. 230 pate Building Inspector Application must be printed or typed FEE SCHEDULE F:Tenant / / /� Location of Job: $0-$1,000=$15.00 Street Lot No. Over$1,000$15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT i lZeS o a t h APPLICANT ADDRE S t f r.? /41e,, P., Po "3,,e3V Y L T oG 16 - APPLICANT PHONE# OW N SF OWNER q< OWNER ADDRESS �y L/:��.� /�,.VC OWNER PHONE 9? '3i1 C ESTIMATED COST$ } IS THIS A CONTRACT COST? Yes _No FEE ENCLOSED$ 1���S - ��� TYPE OF JOB: OR'C New Installation X Alteration/Addition/Repair 1 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATING RESIDENTIAL ❑A/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION:❑ INSIDE❑OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY 10—5 ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK 5 f tve1 //.�p,P f..�f, clbep�<ry C.,«t f.ers THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. ff76. 03yy6Yr- G ( G CT CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE ! Z RESOURCE Date: To: Code Official V' .1)Sc ,-- I, Michael Santaw do give Gepald Bannock, Michele Janota, Shane Driscoll, Sam Bean, Debra Wolfenson, Jason Malachowski, Christopher Lehnow, Craig Rossetti and/or Harold Robinson of Energy Resource by Superior permission to use my license to obtain a permit. n The location of the work is /`� �" t�^ [�� ✓2 Thank you, Michael Santaw STATE OF CONNECTI(VT HF—AVTING,PIPING&COOLING LIMITED CONTRACTOR � MICHAEL P SANTAW 4 " acim.B 447 MILL ST �"r-MONE E "� 1, a .euc: SOUTHINGi'Oiti,CT 064's9 7 Do"; -mow.:" + e> LIC./REG NO. EFFECTIVE EXPIRES �IAWm 21�'t5 H1G.0394641_G 09/0l/2011 OS/31/2012 = 4 Swnwwrm CtIA, SIGNED 1457 Meriden-Waterbury Road•Milldale(Rte.322,Southington),CT 06467 • (860)620-1500 • Toll Free:(866)926- • Fax:(860)620-1501 WWW. .com • Mailing Address: P.O.Box 348• Milldale,CT 06467-0348 - APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 1ao i s6 APP O 1540 SULLIVAN AVENUE Bldg. Permit# 644-2511 ext. 230 Date Building Inspecto Application must be printed or typed FEE SCHEDULE Location of Job: /� $0-$1,000=$15.00 �/y �✓/ �N �� ��r�`'t� Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT J -et)S' O 1 A/PP�ICAN//T ADDRESS 136 It Ye 5' APPLICANT'S PHONE # OWNER A�-A Orr y E' .SaSr,i i'?c»—sc,.�! q 0 se q� OWNER AD RESS /lc f C�p /�•rjaq j'•!/C, OWNER PHONE ESTIMATED COST$ yam, le; 2 s. ely IS THIS A CONTRACT COST? Yes (VNo FEE ENCLOSED$ /6Y.)' G O TYPE OF JOB: �SOR•CO New Installation �00 Alteration/Addition/Repair \� Revised 03/05/10 APPLICATION FOR IIVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑ HEATING D-RESIDENTIAL KKA/C ❑ COMMERCIAL P,-<E'NTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) me a/a 0 �/-'s-'7/q, /Uo 0 TONNAGE ? COOLING CAPACITY(BTUH) 3e, OGv VENTILATION DESCRIBE ALL AIR HANDLING EQ MENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) , d 1C TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY A/PPLLIICATION) J J FUJWTHERPESCRIPTION OF WORK 'r �v N �tqr�Ya�'� !� ��'f�• -+G�ily 1 J THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 30 3-;;,g2 1151 CONTRACTORS LICENSE NO. TYPE / STATE SIGNATURE OF APPLICAN DATE / `� 9 Load Short Form Job: borgen wrl htsoft Date: Jan 24,2012 • Entire House By: Andrews Oil Co. Project • • For: Anthony&Susan Borgen 114 Clinton Drive, South Windsor, ct 06074 Phone: 860-644-9217 Design Information Htg Clg Infiltration Outside db(°F) 8 88 Method Simplified Inside db (°F) 68 75 Construction quality Average Design TD (°F) 60 13 Fireplaces 1 (Average) Daily range - M Inside humidity (%) 50 50 Moisture difference (gr/lb) 45 22 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond GAMA ID Coil ARI ref no. Efficiency 80 AFUE Efficiency 0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 0 ft Actual air flow 1422 cfm High output baseboard 700 Btuh/ft Air flow factor 0.044 cfm/Btuh Total high baseboard 0 ft Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.77 ROOM NAME Area Htg load Clg load Baseboard (ft) Clg AVF (ft2) (Btuh) (Btuh) Low High (cfm) bedroom 1 181 0 3963 0 0 174 mst bedroom 181 0 2397 0 0 105 bedroom2 107 0 2530 0 0 111 office 95 0 2503 0 0 110 kitchen 224 0 9296 0 0 409 dining room 129 0 3407 0 0 150 living room 358 0 8231 0 0 362 Entire House d 1275 0 32327 0 0 1422 Other equip loads 24796 5372 Equip. @ 0.93 RSM 35060 Latent cooling 11232 TOTALS 1275 24796 46293 0 0 1422 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right-Suite—Universal 7.0.14 RSU03006 2012-Jan-24 14 47.0E f�Cp C\Documents and Settings\User\My Documents\Wnghtsoft HVAC\borgen rup Calc=MJB Orientation= Page 1 .�. 9 Building Analysis Job: borgen wri htsoft 9 Y Date: Jan 24,2012 Entire House By: Andrews Oil Co. Pro*ect Information For: Anthony& Susan Borgen 114 Clinton Drive, South Windsor, ct 06074 Phone: 860-644-9217 Design Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature(°F) 68 75 Elevation: 180 ft Design TD (°F) 60 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 44.6 22.5 Dry bulb (°F) 8 88 Infiltration: Daily range T - 21 ( M ) Method Simplified Wet bulb (° ) - 71 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Heatin • Component Btuh/ft2 Btuh %of load Walls 0.0 0 0.0 Glazing 0.0 0 0.0 Doors 0.0 0 0.0 Ceilings 0.0 0 0.0 Floors 0.0 0 0.0 Infiltration 0.0 0 0.0 Ducts 0 0.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 24796 100.0 Adjustments 0 Total 24796 100.0 Component Btuh/ft2 Btuh %of load Waft Walls 1.0 1076 2.9 Ver"Mb^ Glazing 30.2 7644 20.3 ,�, Doors 8.7 288 0.8 Ceilings 1.0 1334 3.5 Floors 0.0 0 0.0 Infiltration 0.4 595 1.6 °"- Ducts 4560 12.1 Ventilation 5372 14.3 Internal gains 16830 44.6 Blower 0 0.0 Duds Adjustments 0 Total 37699 100.0 Overall U-value= 0.088 Btuh/ftZ-°F Data entries checked. ",- -fia- wrightsoft Right-Suitew Universal 7.0.14 RSU03006 2012-Jan-24 14:47:06 AM CADoaxnents and Settings\UsenMy Documents\Wnghtsoft HVAClborgen rup Calc=mio orientation= Pagel Component Constructions Job: bourn wrightsoftx P ate: Jan 24,2012 Entire House By: Andrews Oil Co. Project Information For: Anthony&Susan Borgen 114 Clinton Drive, South Windsor, ct 06074 Phone: 860-644-9217 Design Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature(OF) 68 75 Elevation: 180 ft Design TD (OF) 60 13 Latitude: 42°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(grAb) 44.6 22.5 Dry bulb(OF)°F 8 88 Infiltration: Daily range °F) - 21 ( M ) Method Simplified Wet bulb(OF) - 71 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Ctg HTM Gain tr Bk*W--'F rr-'Flaw MAW Btuh Bkow Btuh Walls 12E-Osw:Fan wall,wd md,1/2"wood shth,r-19 cav ins,1/2" ne 450 0.068 19.0 0.00 0 1.02 458 gypsum board int fish,2"x4"wood frm se 86 0.068 19.0 0.00 0 1.02 87 sw 307 0.068 19.0 0.00 0 1.02 312 nw 215 0.068 19.0 0.00 0 1.02 219 all 1058 0.068 19.0 0.00 0 1.02 1076 Partitions (none) Windows 4A1-2ov:2 glazing,cir low-e outr,argon gas,insulated vinyl fan ne 136 0.470 0.0 0.00 0 27.2 3688 mat,clr innr,1/4"gap,1/8"thk;50%drapes,medium;50% se 21 0.470 0.0 0.00 0 33.6 689 outdoor insect screen;foreground=green grass(0.23) sw 58 0.470 0.0 0.00 0 33.6 1959 sw 39 0.470 0.0 0.00 0 33.6 1308 all 253 0.470 0.0 0.00 0 30.2 7644 Doors 1110:Door,wd pnI type,mtl star star ne 33 0.360 1.0 0.00 0 8.66 288 Ceilings 16B-44aad:Attic ceiling,asphalt shingles roof mat,r-2 roof ins,r-44 1276 0.022 44.0 0.00 0 1.05 1334 ceil ins,1/2"gypsum board int fnsh Floors (none) C -P�1- wrig@7tsoft- Right-Sude'UnMmv.17.0.14 RSU03000 2012-Jan-24 14:47:07 cmoanne a and Settings\U•erwy Doaunen %Wrightson HVACV vensup Calc-WO Orlent•tlon Page 1 ° Pro1ect Summary ry Job: borgen Wrightsof Date: Jan 24,2012 Enure House By: Andrews Oil Co. Project • • For. Anthony&Susan Borgen 114 Clinton Drive South Windsor, ct 06074 Phone: 860-644-§217 Notes: Design Information Weather: Windsor Locks Bradley Field, CT, US Winter Design Conditions Summer Design Conditions Outside db 8 OF Outside db 88 OF Inside db 68 OF Inside db 75 OF Design TD 60 OF Design TD 13 OF Daily range M Relative humidity 50 % Moisture difference 22 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 0 Btuh Structure 27767 Btuh Ducts 0 Btuh Ducts 4560 Btuh Central vent(378 cfm) 24796 Btuh Central vent(378 cfm) 5372 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24796 Btuh Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipment sensible load 35060 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 4835 Btuh Ducts 660 Btuh Heating Cooling Central vent(378 cfm) 5737 Btuh Area(ft') D 127b Equipment latent load 11232 Btuh Volume(ft') 0 10919 Air changes/hour 0.61 0.23 Equipment total load 46293 Btuh Equiv. AVF(cfm) 0 42 Req.total capacity at 0.70 SHR 4.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond GAMA ID Coil ARI ref no. Efficiency 80 AFUE Efficiency 0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 0 ft Total cooling 1422 cfm Total low baseboard 700 Btuh/ft Actual air flow 0.044 cfm/Btuh High output baseboard 0 ft Air flow factor 0.00 in H2O Total high baseboard Static pressure 0.77 Space thermostat Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr19te1t0of1:' RWK-Sufte—Universal 7.0.14 RSU03006 2012-Jan-24 14:47:07 Al.c.1. Mocu nenb and SettftsWserWy Docunwt%Vfthtsofl HVACl xnw.nrp Cak-MJS Onentaffon` Page 1 Job: borWn - wrightsoft' AED Assessment Date: Jan 24,2012 Entice House By: Andrews Oil Co. Project Information For: Anthony&Susan Borgen 114 Clinton Drive, South Windsor,ct 06074 Phone: 860-W-9217 Design Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature(OF) 68 75 Elevation: 180 ft Design TD(OF) 60 13 Latitude: 42°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 44.6 22.5 Dry bulb(OF) 8 88 Infiltration: Daily range °F) - 21 ( M ) Wet bulb(0 ) - 71 Wind speed(mph) 15.0 7.5 Test for • - • Exposure Diversity Hourly Glazing Load 11,00 10,00 9,00 t 8,00 m 7,00 $ 6,00 5,00 4,00 3,00 2,0 1,00 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day ,e Hourty / Average / AED limd Maximum hourly glazing load exceeds average by 28.9%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh C Ad- wriaht exIt` Right-Suite"'Universal 7.0.14 RSU03006 2012Jan-24 14:47:07 AM C:1Doasnerft and S.M1ng.1AJ .My Docum ft\Wright ft HVACtb.W.rtp Cak-Mde Orientation= Page 1 -+ wrightsoft Right-A)Worksheet Job: bMen Entire House Byte: Jan 24,2012 Andrews Oil Co. 1 Room name Entire House bedroom 1 2 Exposed wall 159.4 ft 27.0 ft 3 Ceding height 8.6 ft d 8.0 ft Cool only 4 Room dimensions 13.3 x 13.6 ft 5 Room area 1275.4 ft° 181.3 f? Ty Construction U-value Or HTM Area (ft-) Load Area (W) Load number (Btuh/ft;`F) (Btuh/ft1) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)1 12E-Osw 0.068 ne 0.00 1.02 619 450 0 458 110 103 0 1D4 GG 4A1-2ov 0.470 ne 0.00 27.22 136 0 0 3688 7 0 0 197 1110 0.360 ne 0.00 8.66 33 33 0 288 0 0 0 0 Vdl 12E-Osw 0.068 se 0.00 1.02 106 86 0 87 106 86 0 87 11 , G, 4A1-2ov 0.470 se 0.00 33.63 21 0 0 689 21 0 0 689 V)I 12E-Osw 0.068 sw 0.00 1.02 404 307 0 312 136 116 0 117 r;_CG 4A1-2ov 0.470 sw 0.00 33.63 58 0 0 1959 21 0 0 689 4A1-2ovd 0.470 sw 0.00 33.63 39 0 0 1308 0 0 0 0 W 12E-Osw 0.068 nw 0.00 1.02 215 215 0 219 0 0 0 0 C 1613-44ad 0.022 - 0.D0 1.05 1276 1276 0 1334 181 181 0 190 6 c)AED excursion 0 -267 Envelope losstgain 0 10342 0 1818 12 a) Infiltration 0 595 0 156 b Room ventilation 0 0 0 0 13 Internal gains: Occupants C 230 21 4830 1 230 Appliances Q 1200 10 1200D 1 1200 Subtotal(lines 6 to 13) 0 27767 0 3404 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 27767 0 3404 15 Duct loads 16% 0 4560 0% 16% 01 559 Total mom load D 32327 0 3963 Lov4High Baseboard/Cool Air 01 0 1422 1 0 0 174 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +}+ wr�9x,tsorc- Rlght-Suite"'Unlversa17.0.14 RSU03006 2012-Jan-2414:47:07 '���` C:1Do=rw is and Setting3vise"Documerhimightsoft WACftrgen.rup Calc-WS Orientation Page 1 + wrightsofr Right-J®Worksheet Job: boMen Entire House Date: Jan 24,2012 Andrews Oil Co. By: 1 Room name mst bedroom bedroom2 2 Exposed wall 27.7 ft 10.7 ft 3 Ceiling height 8.0 It cool only 8.0 ft cool only 4 Room dimensions 10.7 x 17.0 ft 10.7 x 10.0 It 5 Room area 181.2 fe 106.6 ft= Ty Construction U-value Or HTM Area Load Area Load number (Btuhlft'---F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 12E-Osw 0.068 ne 0.00 1.02 87 80 0 81 85 65 0 66 {L—_�C 4A1-2ov 0.470 ne 0.00 27.22 7 0 0 197 21 0 0 558 1110 0.360 no 0.00 8.66 0 0 0 0 0 0 0 0 12E-Osw 0.068 se 0.00 1.02 0 0 0 0 0 0 0 0 11 Y—G 4A1-2ov 0.470 se 0.00 33.63 0 0 0 0 0 0 0 0 Y+/ 12E-Osw 0.068 sw 0.00 1.02 0 0 0 0 0 0 0 0 I�—�G 4A1-2ov 0.470 sw 0.00 33.63 0 0 0 0 0 0 0 0 4A1-2ovd 0.470 sw 0.00 33.63 0 0 0 0 0 0 0 0 w 12E-Osw 0.068 nw 0.00 1.02 0 0 0 0 0 0 0 0 C 16B-44ad 0.022 - 0.00 1.05 181 181 0 190 107 107 0 112 6 c)AED excursion -108 -29 Envelope loss/gain 0 360 0 706 12 a b) Infiltration 0 38 0 38 Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 2 460 1 230 Appliances t? 1200 1 1200 1 1200 Subtotal pines 6 to 13) 0 2059 0 2174 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 2059 0 2174 15 Dud loads 0% 16% 0 338 0% 16% 0 357 -F1 F1Total room load 0 2397 0 2530 Lov4 fth Baseboard/Cool Air 0 0 397 0 0 111 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +}r wr�vtitsoTt Right-Sufte"'Universal 7.0.14 RSU030D6 2012-Jan-2414:47:07 A&` C:1Doa rrwft and SettingsWserWly Doamrents\Wrightsoft WAC�borgen.rup Cale-MJ8 Orientation Page 2 - -wrightsoft' Right-J®Worksheet Job: borgen Entire House Date: Jan 24,2012 By: Andrews Oil Co. 1 Room name office kitchen 2 Exposed wall 19.5 ft 21.5 ft 3 Ceding height 8.0 ft cod only 8.0 ft cool only 4 Room dimensions 9.5 x 10.0 ft 10.4 x 21.5 ft 5 Room area 95.0 iN 224.5 ft' Ty I Construction U-value Or HTM Area (tt') Load Area (ftV) Load number (Btuhlft;'F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 %1 12E-Osw 0.068 ne 0.00 1.02 76 56 0 56 0 0 0 0 EL _G 4A1-2ov 0.470 ne 0.00 27.22 21 0 0 558 0 0 0 0 1110 0.360 no 0.D0 8.66 0 0 0 0 0 0 0 0 12E-Osw 0.068 se 0.00 1.02 0 0 0 0 0 0 0 0 11 T--G 4A1-2ov 0.470 se 0.00 33.63 0 0 0 0 0 0 0 0 1qJ 12E-Osw D.068 sw 0.00 1.02 0 0 0 0 172 123 0 125 rE-GG 4A1-2ov 0.470 sw 0.00 33.63 0 0 0 0 10 0 0 328 4A1-2ovd 0.470 sw 0.00 33.63 0 0 0 0 39 0 0 1308 W 12E-Osw 0.068 nw 0.00 1.02 0 0 0 0 0 0 0 0 C 16B-44ad 0.022 - 0.00 1.05 95 95 0 99 225 225 0 235 B c)AED excursion -28 193 Envelope loss/gain 0 686 0 2189 12 a) Infiltration 0 34 0 76 b Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 1 230 4 920 Appliances Q 1200 1 1 1200 4 4800 Subtotal(lines 6 to 13) 0 2150 0 -7985 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 2150 0 7985 15 Duct bade 0%. 16% 0 353 0% 16% 0 1311 Total room load 0 2503 0 9296 LowlHigh Baseboard/Cod Air 1 0 0 110 0 0 409 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. f}+ wr�g�+c=ort Right-Suitev"Universal 7.0.14 RSU03006 2012Jan-2414:47:07 Moaanents and Settingz%UserWly Do uments\Wrightsoft HVAClborgen.rup Cale-MJ8 Orientation Page 3 - wrightsoft Ri ht-JO Worksheet Job: borgen Entire Hbuse Dace: Jan 24,2012 By: Andrews Oil Co. 1 Room name dining mom living room 2 Exposed wall 22.8 ft 30.3 ft 3 Ceding height 8.0 ft cool only 10.0 ft cool only 4 Room dimensions 12.5 x 10.3 ft 13.3 x 27.0 ft 5 Room area 129.1 ft' 357.8 ft' Ty I Construction U-value Or HTM Area (ft) Load Area (" Load number (Btuh/V--'F) (B or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1qJ 12E-Osw 0.068 ne 0.00 1.02 0 0 0 0 261 148 0 150 EL-_-pG 4A1-2ov 0.470 ne D.DO 27.22 0 0 0 0 80 0 0 2177 1110 0.360 ne 0.00 8.66 0 0 0 0 33 33 0 288 V�I 12E-Osw 0.068 se 0.00 1.02 0 0 0 0 0 0 0 0 11 --G 4A1-2ov 0.470 se 0.00 33.63 0 0 0 0 0 0 0 0 gyp! 12E-Osw 0.068 sw 0.00 1.02 96 68 0 69 0 0 0 0 1��G 4AII-2ov D.470 sw 0.00 33.63 28 0 0 942 0 0 0 0 4A1-2ovd 0.470 sw 0.DO 33.63 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 nw 0.00 1.02 83 83 0 84 133 133 .0 135 C 16B-44ad 0.022 - 0.00 1.05 129 129 0 135 358 358 0 374 6 c)AED excursion 237 -8 Envelope IDss/gain 0 1467 0 3116 12 a) Infiltration 0 79 0 174 b Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 6 1380 Appliances C 1200 0 1 01 2 1 2400 Subtotal Pines 6 to 13) 0 2926 0 7070 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 2926 0 7070 15 Duct loads 1 0% 16% D 481 0%1 16% 0 1161 Total room load 0 3407 0 8231 LowlHigh Baseboard ICool Air 0 0 150 0 0 362 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. r{+- w�rgr,csorr Right-Suite^'Universa17.0.14 RSU03OD6 2012-1an-24 14:47:07 ��� C:1Doc merits end SettingsWser\My Doaments\Wrightsott HVAClborgen.rup Cale-W8 Orientation Page 4 APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPR V 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg. Permit# Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000= $15.00 Over$1,000= I Street No. Street Lot No. $15.00 per$1,000 _ or any fraction thereof Tenant Designation Apt.No. APPLICANT PQ- rQ2. APPLICANT ADDRESS 12 APPLICANT'S PHONE# _Qejb�) $3tC 5/3QY OWN OWNER q 3fq< OWNER ADDRESS (0) 4W OWNER PHONE ESTIMATED COST$ /IdV IS THIS A CONTRACT COST? Yes No .� FEE ENCLOSED$ TYPE OF JOB: *I D f O C0 New Installation Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ANO RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑ ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑ MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD Kvq C-r t,y-,2 - j r c, SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE �� APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT y /o a PR�y 1540 SULLIVAN AVENUE Bldg. # 644-2511 ext. 230 Date Bui 'ng Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 Jay ti 240 C R�yE Over$1,000 — Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt. No. APPLICANT APPLICANT ADDRESS 2 �2 F; c,<d Ct. d 66 z- APPLICANT'S PHONE# (�)6 U — 'f, OWNER OWN SF •( q< OWNER ADDRESS C OWNER PHONE C,?6 G) 6' c f c- 9 Z/ 7 ESTIMATED COST$ IJ700 C � U IS THIS A CONTRACT COST? Yes No FEE ENCLOSED $ 3G TYPE OF JOB: $ •CO New Installation C OR C �$ Ic� q Alteration/Addition/Repair Revised 03/05/10 t APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TITE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES YNO RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑ ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑ MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD 10o AM YJ �E 2 U I C f C�a SIZE OF SERVICE 4!Q a A111 2 SIZE OF MAIN CONDUCTORS�� /9G NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS NUMBERS OF PANELS f NUMBERS OF DISCONNECTS REQUIRED? ❑ YES 4/NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE 10 TYPE `STATE SIGNATURE OF APPLICANT DATE BUILDING PERMIT STATE OF CONNkMCUT WORKERS'COMPENSATION COMMISSION Building Permit Affidavit for Property Owners or Sole Proprietors (Conn.Gen.Stat.§31-286b) Pioperty located at In the town of�Co 7� C(j, K,�`C,y Cf. �r Name of building permit applicant: Please check one: 1._1 am the owner of the above property. 2.--Z1 am the sole proprietor of a business. 2A.Name of business fL �,F F �«, cE C �c 2B.Federal Employer Identification Number ff IN) O t1 g - 7 e .................................................................................................................... Pursuant to§31-286b,"a properly owner or sole proprietor[who]intends to act as a general contractor or principal employer"may provide either a certificate of workers'compensation insurance or a"sworn notarized affidavit... stating that he will require proof of worker.? compensation insurance for all those employed on the job site in accordance with this chapter." Please check one: 1._I do not intend to act as a general contractor or principal employer. [Sign and stop here] Signature of applicant 2._I intend to act as a general contractor or principal employer.Applicant must either provide a certificate of workers'compensation insurance or sign the affidavit below. .................................................................................................................... Affidavit I hereby swear and attest that I will require proof of workers'compensation insurance for every contractor,subcontractor,or other worker before he/she engages in work on the above property in accordance with the Workers'Compensation Act(Chapter 568). I understand that pursuant to§31-275 C.G.S.,officers of a corporation and partners in a partnership may elect to be excluded from coverage by filing a waiver with the appropriate District Office;and that a sole proprietor of a business is not required to'have coverage unless he files his intent to accept coverage. Signature of applicant Subscribed and sworn to before me this day of ,200 . (Notary Public!Commissioner of the Superior Court) 1 LO`t' 35 LOT 36 ,_GT 37 9�o 170.00 _o LOT 34 LCT 32 5 1 t; 4i 1tDlNVR `7S O��" AJNTc PROPERTY OF V NO. CLINTON DRIVE SOUTH WINDSOR, CONN. Being Lot No. 33 on map entitled "Map of OAK RIDGE ESTATES Foste ' Scale : 1 " - 40' Sept . 5, 1965-- H a yde n Lr�i Biro T�cZ`pC �' dod t 9 d ad dft AJ HAYDEN L. dRISWOLD C. E. r; a oar r,y. '4' 10 Ulf BWUL46 aw, town � i�M 1YW�i0► Thia-TtM d that this al" eM Weelfleatbns or%trs. c^pies of the propoa.sd ba{Ning tY rt erected at r I street tegetiler wi a mendments stated In 312016etlsn *no Illed with plan and I agree to comply with all zoning, Building and state laws and such orders as shall be issued by the Building Department during pandeney Of this application and final IssuarM of a. bulldln& Permit. xSigned This plan is approved Subic" to the Condition that orders and ordinances rtlgulatlaill building shall be corr:6sisd with. conOtticnally Approved Qnaa filed with Building Inspectorlots '"'�—� fgR vim►V v--�J� i CA /VNI: CERTIFICATION OF ZONING COMPLIANCE Proposed bullding(s), u*a)OrWor structure(:) as shown on With i I s) to be in conformance7 mouth Windsor regulations. Variances 4W SWial exceptions may apply. Date1� r" t (o 1 71 APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPR 1540 SULLIVAN AVENUE Bldg. U 0�3 Bldg.Permit# 1 . 6 ! V 644-2511 ext. 230 Date Building Inspecto Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 l y G L p/t, ✓ z Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT o K^' G�2 �1/�i 2G� 7' to tS APPLICANT ADDRESS !`/S -7 Z z 0.4cf 11"G7 APPLICANT'S PHONE# 2v3 5� 3 —7 — 3 Yo OWNER 0%OWN SFq< OWNER ADDRESS / `/ G L ��1� v /liL. ✓'� X C OWNER PHONE S G 6 v(K CESTIMATED COST$ IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ TYPE OF JOB: SOR,coy' ✓New Installation Alteration/Addition/Repair Q� l�- Revised 03/05/10 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: J-HEATING RESIDENTIAL ❑ AjC ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) �i/N�l /i✓1+ /l'�1 'F -"r�t�C.�J �/2 L�L/r(L �C LO/� /FI ✓niv'7�iJ G� S/� 7 GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY t 20 ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. GrwoZ7r/ �/ G 7/- CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE V V L t_GT 3 6 `OT 37 9C a 170.00 ,? LOT 34 407 33 LOT 32 .J 1� LAO 170.00 FOR BUILDING pURpOSES ONLY PROPERTY OF rq . NO. OLINTON DRIVE SOUTH WINDSOR, CONN . Being Lot No. 33 on map entitled "Map of OAK RIDGE ESTATES Foster St. South Windsor, C♦nn. Scale : 1 " - 40' Sept . 5, 1965 Hayden L. Griswold C. E. Sheet3" Scale 1 " = 40' HAYDEN L. GRISWOLD C. E. Electric # APPLICATION FOR BUILDING PERMIT Plumbin D 114 Clinton DRive HVAC# run J(JA73_ 76 110 n m m n S Date: 7f Sprinkler# Estimated Cost $. 1,9S 3 — FINAL APPROJO M Permit Fee $ 30 Building rre �..�OA COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering Affidavit TYPE OF PRINT ONLY Eng. Insp. Fee $ Appr.forCO. SIGN ON REVERSE SIDE A Total Fee $ TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ �� The undersigned hereby applies to do work according to the following: Applicant -J a H ti o A A Location of Work <<4/ �� *-?" 04 Lot No. Applicant's Address /r'S r 12'7- 3Z Z Tel # V6' -G Z" -/Sc,-' Town Zip Owner Architect Owner's Address ley G 4"- Architect's Address -S 11 L._74 -e n.7s.1 e-% Zip O G"7y Zip Sq. Ft.New Area: 1 st FI. 2nd FI. 3rd Fl. Total New Area Purpose of this permit 5— /Z !i ILL ,����.ml f T�)�"ti ap' 1e40`' A e-�,��'fA 1.115 Lim't f d.-Ac fry City Water❑ Well 0 Septic System ❑ Sewer❑ oup Ins: HO ST�",/ rt. Area Basement Garage Approved byDate f- b 9 Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this b� g and its use is allowed. Signed - -- I hereby apply for a Certificate of Wc.pancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS PA 17-176 AND CGS Electric # APPLICATION FOR BUILDING PERMIT Plumbing# HVAC# 1/y C�irr�t�n lDr�y e Date: ^/ : - ' Sprinkler# Estimated Cost $ / FINAL APPROV LS Building '^ ' J COMPLETE RED BOXED AREAS Permit Fee $ '— Occupancy Fee $ Engineering Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee $ Appr.forCO. SIGN ON REVERSE SIDE Total Fee $ TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ - y The undersigned hereby applies to do work according to the following: Applicant - L� ✓v Location of Work Lot No. I Applicant's Address _ A2 t+lus r'I•4 Tel # Town 1v 0 uQ"a c- Zip(Jb �2 7 Lic.# S L( 3 S Owner h S P 1 Architect Owner's Address I `7 �' '� '�~ Q/' Architect's Address Zip 0& 0 ki Zip Sq. Ft. New Area: 1 st FI. 2nd Fl. 3rd FI. Total New Area Purpose of this permit f r+ zu ►'�_1-Ct + City Water J Well J Septic System J Sewer J �o46o7;Z7 Ins: HO SP Area Basement Garage Approved by Date Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required t distances from all other zones and is located in which this building and itsuse is allowed. Signed d ��7✓ C V L � l I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS INSPECTION FIELD SHEET 03/30/23 Printed by Middleton, Morgan 16 20 50 INSPECTION: 104752 FINAL PERMIT: STATUS APPLICATION: 201800727 LOC: 114 CLINTON DRIVE SOUTH WINDSOR PROPERTY ID: 21300114 OWNER: BORGEN SUSAN A CONTRACTOR: REQUEST BY: PROJ DESC: TEAR ROOF, ICE AND WATER, RIDGE VENT, COPPER FLASHING, WORK ORDER: INSPECTOR: WS-B RESULT: PASS REQUESTED: PRIORITY: SCHEDULED: COMPLETED: 03/30/23 UNPAID FEES 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS: INSPECTED BY VALERIE MUSZYNKSI TO CLOSE OUT OLD PERMIT 1800250 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 05/23/2018 GIS ID:21300114 FEE: 180.00 MUNIS APPLICATION# 201800727 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ALCRAFT INC. ADDRESS: 114 CLINTON DRIVE ADDRESS: 605 WASHINGTON AVENUE OWNER: BORGEN SUSAN A NORTH HAVEN,CT 06473 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: TEAR ROOF,ICE AND WATER,RIDGE VENT,COPPER FLASHING, ARCHITECTURAL SHINGLES.20 SQUARES. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 5/23/2018 I0:33 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 11000005 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 01/06/11 GIS ID:21300114 FEE: 30.00 MUNIS APPLICATION# 201100017 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE ADDRESS: P.O.BOX 348 OWNER: BORGEN ANTHONY W&SUSAN A MILLDALE,CT 06467 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: SET 120 GAL:PROPANE TANK AND RUN A COPPER GAS LINE INTO THE BASEMENT FIREPLACE. r SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 1/24/2011 3:45 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 11000005 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 01/06/11 GIS ID:21300114 FEE: 30.00 MUNIS APPLICATION# 201100017 BUILDING DESCRIPTION: APPLICANT,;' ., LOCATION NAME: ENERGY RESOURCE ADDRESS: I 14'CLINTON DRIVE ADDRESS: 1457 RT 322 OWNER: BORGEN ANTHONY W&SUSAN A MILLDALE,CT 06467 f 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: SET 120 GAL.PROPANE TANK AND RUN A COPPER GAS LINE INTO THE BASEMENT FIREPLACE. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL ',f,I", 1/6/20I 1 2:34 PM_ _ THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1200150 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 04/19/12 GIS ID:21300114 FEE: 150.00 MUNIS APPLICATION# 201200424 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ANDREWS OIL CO. ADDRESS: 114 CLINTON DRIVE ADDRESS: 136 RYE STREET OWNER: BORGEN ANTHONY W&SUSAN A SOUTH WINDSOR,CT 06074 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALLING CENTRAL A/C. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: B G OFFICIAL 4/19/2012 12:45 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1100003 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 01/06/11 GIS ID:21300114 " FEE: 15.00 MUNIS APPLIC1TIt0N#`201100017 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE ADDRESS:. 1457 RT.322 OWNER: BORGEN ANTHONY W&SUSAN A MILLDALE,CT 06467 = 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: SET 120 GAL.PROPANE TANK AND RUN A COPPER GAS LINE INTO THE BASEMENT FIREPLACE. SPECIAL CONDITIONS: ALL WORK TO BE'DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE i i 1100003 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 01/06/11 GIS ID:21300114 FEE: 15.00 MUNIS APPLICATION# 201100017 BUILDING DESCRIPTION: APPLICANT,. LOCATION NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE ADDRESS: P.O.BOX 348 OWNER: BORGEN ANTHONY W&SUSAN A MILLDALE,CT 06467 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: SET 120 GAL.PROPANE TANK AND RUN A COPPER GAS LINE INTO THE BASEMENT FIREPLACE. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 1/24/2011 3:45 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1200182 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 05/09/12 GIS ID:21300114 FEE: 15.00 MUNIS APPLICATION# 201200547 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ENERGY RESOURCE ADDRESS: 114 CLINTON DRIVE ADDRESS: P.O. BOX 348 OWNER: BORGEN ANTHONY W&SUSAN A MILLDALE,CT 06467 ` 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALL 100 GALLON PROPANE TANK,UNDERGROUND PIPING,AND CONNECT TO EXISTING TANK. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 5/9/2012 11:40 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1200145 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 05/09/12 GIS ID:21300114 FEE: 30.00 MUNIS APPLICATION# 201200547 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ELECTREX,LLC. ADDRESS: 114 CLINTON DRIVE ADDRESS: 125 SOUTH STREET OWNER: BORGEN ANTHONY W&SUSAN A VERNON ROCKVILLE,'CT 06066 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALL 100 GALLON PROPANE TANK,UNDERGROUND PIPING,AND CONNECT TO EXISTING TANK. INSTALL OF 8 KW GENERATOR WITH AUTOMATIC TRANSFER SWITCH. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS'APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 5/9/2012 I0:55 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1100103 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 05/11/11 GIS ID: 21300114 FEE: 30.00 MUNIS APPLICATION# 201100415 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: TIM SWEETMAN ADDRESS: 114 CLINTON DRIVE ADDRESS: 25 PARKER STREET OWNER: BORGEN ANTHONY W&SUSAN A ENFIELD,CT 06082 114 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: 100 AMP SERVICE CHANGE. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 5/1 I/2011 2:19 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE