Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
11 PODUNK CIR
r DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is hereby: PERMIT# A pp TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg. Permit# 644-2511 ext. 230 Date Buildi Inspect Application must be printed or typed FEE SCHEDULE Location of Job: � � PodumK _AR,C/� $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT &110 A6M St\*Niies APPLICANT ADDRESS -P o UD O so c s C 6 0 6 APPLICANT PHONE# O W N S F,q OWNERAIK&M t OWNER ADD SS / I �c��► AJ e lKe /eC107 _ a # ,r OWNER PHONE no— �c3a-- Is OESTIMATED COST$ '/ O o o. D O IS THIS A CONTRACT COST? Yes _No FEE ENCLOSED$ 05, 1 •C SO OL/�� TYPE OF JOB: � I�`'<l 3 R _New Installation Alteration/Addition/Repair Revised 4/01//2002 1� APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE YSTEM: TYPE OF UILDING: P.JHEATING RESIDENTIAL A/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HE TING EQ e NT(I CL MG �Bc ODEtN .)` ► (� GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION :❑INSIDE❑ OUTSIDE CAPACITY ❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) &' FURTHER DESCRIPTION OF WORK A ► /`� THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3©,3 03A -�- CONTRACTORS LICENSE NO TYPE STATE Q� SIGNATURE OF APPLICANT r - DATE D O t 1 r ' 6 . LO, OE L CORPORATE OFFICE P.O. BOX 548, WINDSOR LOCKS, CT 06096 HOME SERVICES Plumbing • Heating • Electrical • Air Conditioning • Water Quality Solutions o3k 8, To Whom This May Concern: Aiello Home Services authorized Linda Dawson-Hayes, Russell Horrocks, Stephen Birch, Garrett Cardwell, Dave Arildsen,Tim Lynch, Joe Sparveri, Keith Tyler, Randy Weidig, Shawn Greenlaw to pull permits for our company for any plumbing, heating or air conditioning replacement(s) or new installation(s). If you have any questions please call our office at 860-292-2600. This letter is for a permit for the property located at: i I A d I.)tj i� C(k c Ae F &0 L)4 W'j ADA, L� Homeowner: V 1(C.4 N 74KeAK Permit Fee Amount: $ /Os', 0c) /J J Sincerely, Michael Jezouit President STATEOF CONNECTICUTOF CONNECTICUT DEPARTMENT OF CONSUMER PROTECTION DEPARTMENT OF CONSUMER PROTECTION HEATING,PIPING 4 0) I '__DUI, MITED CONTRACT LIMITED SHM�E�T C'brl i RACTOR MIC R (QUIT MIC R� ?UIT WIND$OR I ,CT`�06096 WIND bIr L* � -7, 6096 �� LIC./REG N a IVE�{ EXPIRES LI ./REG N HTG.0303032-Si 08/31/2009 SHM.0005345-SM (o 08/31/2009 / Nsr SN IGED `SIGNED Local 860-292-2600 •Connecticut Toll Free 1-888-956-4455 Fax 860-292-2690 Connecticut License Numbers 9 P1-203350 • Si-303032 • E1-193730 ovoe Rhvac•Residential$Light Commercial HVAC Loads Elite Software Development,Inc. Aiello Home Services Boiler Replacement Windsor Locks CT 06096 Page 2 Project Report General Project Information Project Title: Boiler Replacement Designed By: David Arildsen Project Date: Tuesday, October 14, 2008 Client Name: Viran Thakran Client Address: 11 Podunk Cir Client City: South Windsor Company Name: Aiello Home Services Company Representative: David Arildsen Company Address: 600 Old County Circle Company City: Windsor Locks, CT 06096 Company Phone: (860)292-2635 Company Fax: (860)292-2690 Company E-Mail Address: d.arildsen@aiellohomeservices.com Company Website: www.aiellohomeservices.com Company Comment: The right comfort for your home. Design Data Reference City: Windsor Locks, Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees Elevation: 169 ft. Altitude Factor: 0.994 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: -5 0 45 70 46 Summer: 95 72 50 72 23 Check Fi ures Total Building Supply CFM: 1,217 CFM Per Square ft.. 0.839 Square ft. of Room Area: 1,450 Square ft. Per Ton: 554 Volume(ft3)of Cond. Space: 13,050 Air Turnover Rate(per hour): 5.6 Buildin Loads ,. Total Heating Required With Outside Air: 46,209 Btuh 46.209 MBH Total Sensible Gain: 22,623 Btuh 92 % Total Latent Gain: 2,070 Btuh 8 % Total Cooling Required With Outside Air: 24,693 Btuh 2.62 Tons(Based On 72% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. T:\Installation department\Load Calc-Dave\Thakran.rhv Tuesday, October 14, 2008, 9:42 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Aiello Home Services Boiler Replacement Windsor Locks,CT 06096 Page 3 Miscellaneous Report System 1 Main Floor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: -5 0 45 70 45.89 Summer: 95 72 50 72 22.91 Duct Sizinglnputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00030 0.00030 Pressure Drop: 0.0500 in.wg./100 ft. 0.0500 in.wg./100 ft. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 600 ft./min Minimum Height: 0 in. 6 in. Maximum Height: 18 in. 10 in. Outside Air Data Winter Summer Infiltration: 0.472 AC/hr 0.200 AC/hr Above Grade Volume: X 13.050 Cu.ft. X 13,050 Cu.ft. 6,159 Cu.ft./hr 2,610 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 103 CFM 44 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 25.15 = (1.10 X 0.994 X 23.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 15.49 = (0.68 X 0.994 X 22.91 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 82.00 = (1.10 X 0.994 X 75.00 Winter Temp. Difference) _._ - Y - . -- Duct Load Factor Scenarios for System 1 —.... Attic Duct Duct Surface From No, Type Description Location Ceiling Leakage Insulation Area MDDI 1 Supply Main Basement - 0.12 0 442 No 1 Return Main Basement - 0.24 0 164 No T:\Installation department\Load Calc-Dave\Thakran.rhv Tuesday, October 14, 2008, 9:42 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Aiello Home Services Boiler Replacement Windsor Locks,CT 06096 Page 4 Load Preview Report , HasM.t _ ec` ft'.'` � `�Sen`` Cat Net' Sen Ht"rSs Sy Ss Act Duct Scope AED Ton Ton /Ton Area Gain Gain Gain Loss CFM CFM CFM Size Building 2.06 2.62 554 1,450 22,623 2,070 24,693 46,209 604 1.217 1.217 System 1 Yes 2.06 2.62 554 1,450 22,623 2,070 24,693 46,209 604 1,217 1,217 18 Duct Latent 596 596 Humidification 3,183 Zone 1 1,450 22,623 1,474 24,097 43,026 604 1, 1 1,217 18 1-Bedroom 1 750 10,363 1,137 11,500 21,438 301 5N 558 1-10 2-Living 700 12,261 337 12,598 21,588 303 t360 660 6-6 T:\Installation department\Load Calc-Dave\Thakran.rhv Tuesday, October 14, 2008, 9:42 AM APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074 (PHONE) 860-644-2511 EXT. 230 DEPARTMENT DECISION PERMIT NUMBER: APPLICATION IS HEREBY: Wz-z APPROVED: BLDG.PERMIT NUMBER: DATE INSPE OR LOCATION OF WORK: I� �oj dc APPLICANT: OWNER: TYPE OF STRUCTURE: l O NEW BUILDING NAME:� f�'� �'.L[� NAME:�/ C✓V ]]2a ❑ADDMON PHONE NUMBER: iS o- lC,� K31 PHONE NUMBER: ❑EXISTING BUILDING ADDRESS/d /�`e-A` V �bC L c+ ADDRESS:1 1�o V.fl C .�1/c/ TYPE OF USE: ❑RESIDENTIAL. ❑COMAffiRCIAL ELECTRICAL INFO ATION: FURTHER DESCRIPTION OF WORK: TYPE OF INSTALLATION: c� G/D f j 30 An C d Yy ou C--,�C U, SIZE OF SERVICE: CvIA ez /-sD r U✓1 SIZE OF MAIN SERVICE: /UC� ���ih� DI�TC) NUMBER OF METERS: a C� /I C�W r AoAd I c r to A .L n I,,\I C`C NUMBER OF PANELS: NUMBER OF LIGHT CIRCUITS: ESTIMATED COST:S /O O C)•O n NUMBER OF SWITCHES: 1 NUMBER OF LIGHT FIXTURES: FEE ENCLOSED:S NUMBER OF A/C CIRCUITS: C,2 FEE SCHEDULE:$18 PER$1,000 OF THE ESTIMATED COST. NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS$1.00 OVER. (.26 CENT EDUCATIONAL FEE INCLUDED AS NUMBER OF OUTLETS: / PART OF THE PERMIT FEE) THE UNDERSIGNED NEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT//BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: b TYP STATE: SIGNATURE OF APPLICANT: DATE: lt-�aoLgp0y3-o p f O S S APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074(PHONE) 860-644-2511 EXT. 230 DEPARTMENT DECISION PERMIT NUMBER' APPLICATION IS HEREBY: APPROVED: BLDG.PERMIT NUMBER: DATE INSPECTOR LOCATION OF WORK: �� ��C� K c��l C- {y /V�L►��C I (� APPLICANT: OWNER: TYPE OF STRUCTURE: `/ o NEW BUILDING NAME:��(40 I/M ,6 �R �U�F, NAME: 1 Fr A* ❑ADDITION PHONE NUMBER: , •O' �t� _6 S PHONE NUMBER: `I EXISTING BUILDING ( ADDRESS: wC0 1 e- ADDRESS: f I c, lJ N V 6A o w4 -sex) � �' �O ` TYPE OF USE: 06 oo L J 060) Y RESIDENTIAL o COMMERCIAL HVAC INFORMATION: y� FURTHER DESCRIPTION OF WORK: } r/ TYPE OF SYSTEM: ❑HEATING XAIC 6 ClUilk' A4,,O � CfJ1L/GX(LL HEATING: (IUbk lt(L"t- !{(mac TOTAL HEAT LOSS(BTUH) T (HEAT LOSS SHEET REQUIRED) `1UU5 G_ 1� �� 1� DESCRIBE ALL HEATING EQUIPMENT(INCLUDE MAKE AND MODEL NO.): ESTIMATED COST:S V W '� AIR CONDITIONING: DESIGN TEMP:OUTSIDE C15 °F INSIDE J�0 °F DIFFERENCE If P FEE ENCLOSED:S TOTAL HEAT GAIN(BTUH) K S(HEAT GAIN SHEET REQUIRED) C DESCRIBE ALL COOLING EQUPMENT(INCLUDE mMAKE AND MODEL NO.): FEE SCHEDULE:$18 PER$1,000 OF THE ESTIMATED COST. ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS t $1.00 OVER. (Z6 CENT EDUCATIONAL FEE INCLUDED AS PART OF THE PERMIT FEE) It THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE/PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: 0 6 TYPE: STATE: SIGNATURE OF APPLICANT: DATE: �ao(goo 93� LEGEND 1. SET POSTS AND 2 STAPLE THE WIRE REFERENCE NOTE: ARCHITECTURAL INFORMATION S ANGLE POSTS EXCAVATE A B'xe' MESH FENCING TO BOUNDARY AND TOPOGRAPHIC INFORMATION ARE TAKEN FROM PLANS o IRON PIN TO BE SET 5' UPSLOPE %RE __ POST UPSLOPE FROM POSTS. THE END OF THE POST o MONUMENT TO BE SET FOR SELF-tt FENCING ENTITLED 'OAK MEADOW-SITE PLAN OF DEVELOPMENT', SHEETS 2 AND 3 HOUSE STYLE NJo DEc."8 Z[�2 'LLD �- OF 6, SCALE 1's40', LAST REVISION 8/18/93. PREPARED FOR HUNTERS _ -3-OQ_ _ EXISTING CONTOUR CLEANING. °5• GREEN DEVELOPMENT CORPORATION. BY DESIGN PROFESSIONALS, INC.f 12' MIN SQUARE FOOTAGE _ 300 PROPOSED CONTOUR :337 S.F. ZONE: DESIGNED RESIDENCE HOUSE COLOR L„�t ���y —w—w— WATER MAIN TRIM COLOR 5��.ac sr�r —G—G— GAS MAIN THIS MAP AND SURVEY WERE PREPARED IN ACCORDANCE TO A-2 C _lNvr£KS x 287.3 PROPOSED SPOT GRADE STANDARDS OF HORIZONTAL ACCURACY AS DEFINED IN THE ROOF COLOR Cotv,✓�at� SILT FENCE RECOMMENDED STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT' PREPARED AND ADOPTED BY THE CONNECTICUT NOTE; 3. ALL UTILITIES IN THE ROADWAY ARE TO 3. ATTACH FILTER FABRIC To 4. BACKFTLL THE ASSOCIATION OF LAND SURVEYORS, INC., SEPTEMBER 24, 1992. 1. ROOF LEADERS TO BE DISCHARGED ON BE INSTALLED IN COMPLIANCE WITH THE FABRIC IT TO THERE FTRENCH CING �D ��D TRENCH EXCA AND SOIL SPLASH PADS. APPROVED OAK MEADOW PLANS. I TO THE BEST OF MY KNOWLEDGE AND BELIEF THIS MAP IS 2. FOUNDATION LANDSCAPING PER SHEET '{, Nov6a ;.. ro ec FWviPPgO w/rr SUBST Y RRECT S NOTED HEREON. cor�ACTED� _ L1 OF THE OAK MEADOW PLANS. .�1 6./M.o PUMP iv r.,-� ttiA6F_HE.vT. BACKflLL - -- _ 12882 i - RICHARD P. MARTEL UC. No. MAPLE LEAF CONSTRUCTION, INC. 1750 ELLINGTON ROAD #3 \ SOUTH WINDSOR, CT. 06074 CONSTRUCTION OF SYNTHETIC FILTER BARRIER (203)644-3500 a PROPOSED UNir i Ad N5836'13'E � C Ip aR Dry Vbl Z O & / 0. 1✓ G/-- -�� 7y F.F. = 85.0 N \ ; 79. £ o ez s IJ,911 sq. ft. `\ \ m \ \ B I.91 o 00 \ m . \ �\- UMIT OF RE6VLA7ED / F F CO "•. C.B. 7 _ _ _ B 5 AREA UNE .,. 'I a 4. � T.F, gi.29 7g.<. � � ,0 A �. � r, '.� — r /=o J� I — ?2. - - r 220.34 •ir-o 14J ` � ���oJcO � PROPOSED UN/T � L A,now is sH m NOTED.DOSING U�IT REVISIONS GRAPHIC SCALE OAK MEADOW N8 VENDW7 1.UHLESS AS SHOMN ARE BASED ON BEST -_ (203) 291-8755 SHEET AVAILABLE SH LD OF FIELD �� To maK _ 20 D ,o 20 eslgn IL®'�' ®o LOCA7� Maw 1 B ALL LICENSED ARE S V srAa®N O RELn rofessionais, Inc.BY A LICDISID 1MlD SURVEYOR PRIOR TO UCTIck ��}}''��1T� �/1 I CIS PLAN is INVMJD UULESS IT BEARS THE P®DUNK C RCILIE aury er. .ore Na• eazal`-0 �F� BpRESSON SEAL AND ORxmAL SIGNATURE 1 inch = 20 feet civil engineers • planners • surveyors OF THE PROFIMSMAL ENONEER/SURVEYOR. NO. DATE DESCRIPTION BY 441C governors highway, south winesor, connecticut 06074 SOUTH WINDSOR CONNECTICUT JDATE 9'/5'9D �I � 9 s RECE1VEi SEP 1 7 1993 SEP ? 1993 > 10 t� South wind:,of- Town of south Winds,, BUILDING DEPARTMENT Engineering 11 Cy Uept, ti cam-' to IKE 4U4 DJN6 DEPf 1�tNn ,I;i 'N►NDSOR CERTIFICATION OF ZONING COMPLIANCET hie eettt�d tnet this et06 and speeifieattons arc true <op� 4M the proposed bfallill or alterations =o b• Proposed building(s), use(s) andjor structures d erecte a +4� 11 Street as shown on this plan appears) to be f n �d n conformance with current South Windst r together arkh amendments stated in application zoning. }fled with plan and I agree to comply with a� it be regulations. Variances and special exceptions Building and state laws and such orders as endencho issued by the Building Department during P may apply, and final issuance of o buildinO of this application Date q�ZO - A/A3J`M1 permit. �Spprujaj � � tSigned o thecondition that ZonThis Pling building shall be En{orceme�lt C��f�cer orders and ordinances reg compiled with. These filed with Conditionally Approv04 Meal auilding InspectQ9 Qsq�:) Date LEGEND I HEREBY DECLARE THAT THIS MAP IS SUBSTANTIALLY CORRECT. THIS MAP O� IRON PIN 10 BE SET AND SURVEY WERE PREPARED IN ACCORDANCE MTH THE STANDARDS OF A CtASS A-2 SURVEY AS'DFFINED IN 111E "RECOMMENDED STANDARDS FOR 1.1 MONUMENT TO BE SET SURVEYS AND.MAPS IN 4VIE STATE OF CONNECTICUT' AS PREPARED AND x 287.3 EXISTING SPOT GRADE ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC., ON 300_ _ EXISTING CONTOUR $EPIEMBER 13, 1gs4,:. FTECTIVF NUARY I, 1. —w—W— WATER MAIN * `--�L 126az —c—c— GAS MAIN SURVFVOR'S SIGNATUR LIC, NO. NOTE: f 1. SANITARY SEWER INVERT ELEVATIONS TAKEN FROM INSPECTION REPORT PROVIDED BY CONTRACTOR. `r 2. ALL ITEMS DEPICTED ON THIS PAN HAVE PEEN VERIFIED IN THE F1E1_D AS TO LOCATION, ELEVATION AND COMPLETENESS. c 1 ZONE: DESIGNED RESIDENCE 9 � � 44.'1' \-T dt N AL, � � 1 f C lG J /A N 4 8 \ \ �. /o' Qe� 8t.1 i c8t.o 220.3�l _ .... _ ✓' « e_ =e�,� / v e 04 01 O r 80 Op e t e x eo i. JNtFM OTN01Mf NOTED, �,0 VMUTY REVISIONS (203) 291—e755 SHEET LaCATlwo AS Sews►, ARE BASED ON for ---- - --- GRAPHIC SCALE ��s! MEAO�kj 1 AVAnaaE IWFORNATIaN. ALL E7O1TINo Ul1UTIE3 '� 0 zo Os��n ACT �/o. 9 A S -BU/LT 1 SHOULD BE FIELD 'JE]aM PRIOR TO CONSTRUCTION. -_ -_-- 2 ALA UTRITIES ARE TO BE STM M IN THE Rf1D Q-- 1 ' �O�e Q�'O �'Q' Inc. ■ BCONA UOINSED LAND SURVEYOR PRIOR TO - _ v V V �CO�U�K c��-Pc�E �OF a. THS PLAN IS WVALID BE UWUM IT MARS THE ON 6r U atA .0� t�8 Z59 SPRESMOH SEAL MO OMOtNAL SIaNAT-RE --- --- 1 Inch = 20 feet civil engineers 0 Planners 0 surveyors OF 'W PROFEMONAL ENOMEM/^SURVEYOR Na DATE oESCRipNON BY 441C governors highwoy, south windeor, eonnecticut 06074 7- O*IXW or. IFPAY PAM 4 eL'T/ APR 2 7 im South Windsor BUILDING DEPARTMENT TO THE BUILDING DEPT. TOWN OF SC;t-iH y.:j .,),_j, This certified that this plan and speafi ilb".s are l'-e Copies of the proposed building or a'teratioos to be erected et oo Street Loge ih amendments stat d in application and filed with plan and 1 agfee to comply with all Zoning, 1 Building and state laws and such orders as shall be fi issued by the Building Department during pendency Of this application and final issuance of a buildinig N 7 permlt. 5rgned r This t-t.,n is approved subject to the Conpition that Q ordcra rnd .,rdinanees regulating building. shall be compu„t liv qb `� CotWrt�onut�Y Approved Thrse filed with Baitding fnspevtor Data D Q APPROVES ._ti��l�' TOWN OF SOUTH v.INDSOR ENGINEERING DEPART MENT DATE: —Z .:,tom ?E 0;) &L H(.-IAA E -y- LEGEND 1. SET POSTS AND 2 STAPLE THE rnRE REFERENCE NOTE: ANGLE POSTS EXCAVATE A 8"x8" MESH FENCING TO BOUNDARY AND TOPOGRAPHIC INFORMATION ARE TAKEN FROM PLANS ARCHITECTURAL INFORMATION pS i S' STABLE PAST UPSLOPE FROM POSTS. MANE THE END OF THE POST IRON PIN TO BE SET FOR STABILITY FENCING AND SUFV ENTITLED 'OAK MEADOW-SITE PLAN OF DEVELOPMENT', SHEETS 2 AND 3 HOUSE STYLE NJoDE�„B 2 c-2 0 MONUMENT TO BE SET CLEANING 1 OF 6, SCALE 1'-40', LAST REVISION 8/18/93. PREPARED FOR HUNTERS _ _ OQ_ _ EXISTING CONTOUR 95• 12' MIN. GREEN DEVELOPMENT CORPORATION, BY DESIGN PROFESSIONALS, INC. SQUARE FOOTAGE ;337 S.F. 300 PROPOSED CONTOUR L ZONE- DESIGNED RESIDENCE HOUSE COLOR 61,(- ���y —w—w— WATER MAIN TRIM COLOR s" a` —G—G— GAS MAIN T _ THIS MAP AND SURVEY WERE PREPARED IN ACCORDANCE TO A-2 IW acAc.G 6HVrf"l, x 287.3 PROPOSED SPOT GRADE STANDARDS OF HORIZONTAL ACCURACY AS DEFINED IN THE ROOF COLOR Cj III III SILT FENCE 'RECOMMENDED STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT- PREPARED AND ADOPTED BY THE CONNECTICUT NOTE: 3. ALL UTILITIES IN THE ROADWAY ARE TO 3. ATTACH FILTER FABRIC TO 4. BACKFILL THE ASSOCIATION OF LAND SURVEYORS, INC., SEPTEMBER 24, 199Z 1. ROOF LEADERS TO BE DISCHARGED ON BE INSTALLED IN COMPLIANCE WITH THE FABRIC ITTORE THHE TRENCH AND EXTEND THE EXCTRENCH AND ADTEDMSOILT SPLASH PADS. APPROVED OAK MEADOW PLANS. I TO THE BES�MY KNO GE AND BELIEF THIS MAP IS 2. FOUNDATION LANDSCAPING PER SHEET .�• H006r- /s ro e& �q�,rvFp „l,rr COMPACTED SUBSTAAITALLY RRIE S TED HEREON. Ll OF THE OAK MEADOW PLANS. A SuM� FUNP /A/ 7.YE BASEH��T, BACKFILL d 12882 RICHARD P. MARTEL L1C. No. MAPLE LEAF CONSTRUCTION, INC. 1750 ELLINGTON ROAD #3 CONSTRUCTION OF SYNTHETIC FILTER BARRIER \ �` SOUTH WINDSOR, CT. 06074 (203)644-3500 ► \ GZt^ ` PRDPOS£D uNir 5 ' `,�„✓ N58.36'13'E : \ o, lea o• —Q' 94.38 ' \ c D,C4, / �� O cl = C DG r0 •� \ 9 (o a N r _ B z , \ u w w p L� --.1 �I B5.p N r ` \ oy1T -6 \ W.:79.1 G ` f o B7 s ""�5 13,911 sq. ft. B e LIMIT OF REGY/LA rED I.91 0o mN \ , 1 Iv ' *annui�.� I i ear � , � .<, c4e4°�F of..CON,, C.B.1 7 � � Z\, / � � AREA LINE , L/ , a+•yC; ,t d. A.yv.Cl, T.F, 81.29 NJ = 78.le r 414 220.34 r -- f ; 1 PROPOSED UNIT i 1.UNLESS oS SHOW NOTED,EXISTING UTILITY REVISIONS GRAPHIC SCALE (zo3) 2s,-e7ss OAK MEADOW ®��4 SHEET AVAILABLE AS SHOWN ARE L O a BEST 20 0 10 20 Ssl�n �T1�1 /j�$�,/�`gay (j/� SHOULD S araD YERW ALL EXff To ONTWU5 ]LOT ® It 1�.T®o 1(1) �11/nLP51 Il Iw11[l RA� 1 �� TI TIESD Y�PSTAI To N THE M13-D rotessionals, Inc. �}�\ �UT iV `j/ 1 2 All UTILITIES ARE TO BE STN®W THE flELO CO A LCT]ISED LAND SURVEYOR PR10R TO ®1J./�d V� \Y(►���m OF By A LIUCTIOIL 1� 1111 IIiM/THIS PUN IS INVALID UM.ESS IT BEARS THE DRAW B1`. .CB NQ• drtl�-I oN SEAL AND ENOIN l�A� 1 inch = 20 feet civil engineers • planners • surveyors - 1 OF THE PROFESSIMAL ENOWEEB/SURVEYOR DATE DESCRIP17ON NO. BY .l 441C governors highway, south windsor, connecticut 06074 SOUTH WINDSOR CONNECTICUT QYEZ7 aor. R44 DAtE 9 /7.9� OF ZONING COMPLIANCE cturels CEK t 11 IC.A use(sl andjor stru SEP 17 1993 proposed buildinglslr earls) to be in Provo this Plan aPP Windsor as shown on with current South tions South Windsor conformance ecial excep BUILDING DEPARTMENT regulations. Variances and spec, may aPPIY• _ to Date towN uE Zo q Enfcrceme�It C5 c;r DEP1. aro tcuo ti 1p 1NE BUILDING and sPecitieat:o^s to M hit cenitied thaoVpyed this (building or alterations c.oDief It the Or ' SttKt erected al /, (� ✓l in °DPUcation and � ✓r nin4 1(7� to Corn with ell to cots stated shall W to{ether with amend agree nQt and such orders es Bled with Dla^ °nd during te pe Partment of a building so in and hetguitdin8 issue isWed beDPllcetio^ end final rr—}'�d� e(► of this Permit. t e condition thbo ved sublect to shell signed puilding sour regutaune This Plan ordinances orders and 3he°e tiled comDtied with ition ally Approved Cond Inspect4S (/ J gullding vote �r a LLGEND I HEREBY DECI.ARE THAT THIS MAP IS SUBSTANTIALLY CORRECT. THIS MAP c AND SURVEY WERE PREPARED IN ACCORDANCE WITH THE STANDARDS OF A IRON PIN TO BE SET CLASS A-2 SURVEY AS DEFINED IN THE -RECOMMENDED STANDARDS FOR [7 MONUMENT TO BE SET SURVEYS AND MAPS IN PIE STATE OF CONNECPCUT' AS PREPARED AND x 287.3 EXISTING SPOT GRADE ADOPTED BY -Y"F CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC.. ON SEPTEMS 13. 198�4, FFECn IARY 1. 1 7. —�-- EXISTING CONTOUR —w—W— WATER MAIN '�---� � _ I2eBs —c—c— GAS MAIN r11RVFYOR'S SICTJARJPF - _ -- UC. NO. NOTE: I. SANITARY SEWER INVERT ELEVATIONS TAKEN FROM INSPECTION REPORT PROVIDED BY CONTRACTOR. 2. ALL ITEMS DEPICTED ON THIS PLAN HAVE BEEN VERIFIED IN THE FlEtD AS TO LOCATION, ELEVATi NI AND COMPtEIENESS. ZONE: DESIGNED RESIDENCE ,,go 0 1 O \s a 7.4� \Ll- \1� FI, V u, , _- v S r \ N \ r N , G ��r• i Rl �e� x8Z b i�� �x81.o 220.3 7 eo uNuESo oTMMSE NOTEn. ExiSm+a JTurr REVISIONS (203 291-8755 SHEET LOCATIONS AS SNOSN ARE BASED ON KST - ---------__ --._ GRAPHIC SCALE �.4/� MGcAd AjAVALAO ------ SHO"E INiDIWATDN. ALL PRIOR ORSTNo UnmUMu 0 z.� esign �_„' moo. 9 A S -6G//Lr P!_..4.✓ — --- - _, �' RED�� '� �E __ Jrofesslonals,, Inc. �o,o , K2 ALL UT1(Tlb ARE TO OE lTN®M TIE RElD _ _9Y A UOENSED LAND SURVEYOR PRIOR TD _. ._._. __--OONS1RUcnOR _ -- --- ---- --- - G'��Pc•�E OF I TiS PLAN LS NVAUD UMLLESS IT KARS THE [YPARN B)! .�'J)t .qI AY.4B8'Z'j9 SCION SEAL AND OWNAI 242NATURE rNE -------- I Inch = Ec feet ' civl engineers • planners • Surveyors Or TIC PROfT39ONAI ENaNEM suRVErvR DATE DESLRIPITON BY 441 C governors highway, South windsor, connecticut 06074 nt�TN N�=.n E G r 0+4n1ED/Y!RPH OA>F 5/ ZL � s tiry qP cr- Jib r4 C .� $�4 A Cj APR 2 7 1944 South Windsor BUILDING DEPARTMENT TO THE BUILD114'u DEFT. TOWN Of SJUTH Wl4DSVR This certified that this plan and speein"tions are true copies of the proposed building or alterations to be erected at^ /� Strref toge er with amendments stated in application :n• tiled with plan and i agree to eomp2y with a4 ionin, Building and state laws and such orders as shall ^ issued by the Building Department during pendent, of this application and final issuance o: a buUdin, permit. Signed _ This plan Is approved sub;ect to the condition tha! orders and ordinances regulating bailding shall be complied with. Conditionally Approved These filed with Building inspector sip �J pY Q4Y111; Date _ e-a,y+ Y APPROVED .., Ot TOWN OF SOUTH WiNDSO'R -\ ENGINEERING DEPARTMENT p M* �, 1800203 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 06/20/2018 GIS ID:73400011 FEE: 18.00 MUNIS APPLICATION# 201800930 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: HAMMICK JAMES T ADDRESS: I 1 PODUNK CIRCLE ADDRESS: 292 KELLY RD OWNER: THAKRAR VIREN R& S WINDSOR,CT 060743126 1 I,PODUNK CIRCLE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: NEW 30 AMP 240 VOLT CIRCUIT FOR NEW CONDENSOR UNIT/AC NEW CIRCUIT FOR NEW AC AIR HANDLER AND LIGHT: w SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED B IE BUIL ��EPARTMENT. CONSTRUCTION TYPE: 7- OCCUPANCY GROUP: BUILDIN6 OFFICIAL 6/20/2018 3:44 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE