Loading...
HomeMy WebLinkAbout109 JACQUES LN DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT RO 1540 SULLIVAN AVENUE Bldg.Permit# Ainspeao, 644-2511 ext. 230 K)Date Build Application must be printed or typed FEE SCHEDULE Location of Job: b5� /D9 JQrC4 vc?s $0-$1,000=$15.00 Street No. U Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS G C S En-L,?-L; , C-7- Oro O4r->.L APPLICANT PHONE# �64__ //— ��jam- Z� O� OWN Se OWNER ��1 -11 14 itJ O r OWNER ADDRESS 9 O OWNER PHONE PA n C = ESTIMATED COST$ Z /DO _ IS THIS A CONTRACT COST? '''Yes _No v41 FEE ENCLOSED$ �/V a.•// TYPE OF JOB: �SO R C0 -14ew Installation �'-Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A U4(fSIDENTIAL BUILDING PERMIT APPLICATION? ❑YES ❑NO ❑BUSINESS CURRENT USE AND OCCUPANCY �-eJ t o/e� ❑ASSEMBLY Q MERCANTILE ❑EDUCATIONAL FUTURE USE AND OCCUPANCY r r ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑GARAGE ADDRESS ❑MIXED USE (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS _S EL/ NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS r REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Up4racJQ .Selv/ � c -b 40 0- THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. I fK0 9 G &-::7- t C,�— CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE /l' l 7— 135 73 11.sae E. x7yppa k A aaoai+aMit (OP Civil Engimem Env S P,q�C. Gla stonbwyv Connectkmt `'`CTjO/V 3 PACE ) /65- 236- I /p"'E� ���a� �/ ., .� 100 q2 94 9b �/ ol'� AREA = 27. 888 5.F �or �, -a � -Jr kko 9L ' 100 to � ate• za' z _ 1pg -, G��a•g2 5.po a 2 01E �y VAO -Lovsmc- v10L.AaloNS �ouN�Z1oN ('oCAT�D AS SNa�l1, IZ-I(o-83 VMS Lotwn Ito" from mp al flu O�Platl / (}J�� �10 To Clerk,s Office anti led, section 8 rileaeant, Valley Hanel South Windsor, Coon." Scale 1"" bOl Date 3-28-83 A-ZO TONE Hop No, 220-TS-I U Row --- by Rai no E. Hyyppa & Associates Glastonbury. CT. PRrPAREO FOR I tweby certify that this map and survey were W9PW0d In PLE A54 NT VALLEY WO M E5 accordance with the standards of a Class A•2 survey as defined in the existing Code of Practice for Standards of Accuracy of 5OUTN WINDSOR, COWN• MWWSP and Maps. sdop'ted bit the Oo WC"Cut AMOCie On of d0. pATP- 10-28-85 L= ' ` 8CAN1j�DD,_158 ro sic•• Reino E. HTTpps & A ssociatON Civil Engineers E Glastonbury, Connecticut SFCTjON 3 C��Ery P' 3 94/ / / AREA = 27 e8R S. F ol U jol 4/ io — om 1� LP -NOTE: Lot lines from sup on file in ?own Clerk's Office entitled, "Plot Plum r Section Pleasant Valley Hones p South Windsor, Conn." Scale 1"" u0' Data A-20 ZONE ?lap No. 220-78 - ' - Rae. -- by Ref no E. Hyyppa b Associates Glastonbury, CT. pr,'EPA.R E D F012 I hereby certoty thit this mao and survey were prepared In PLEASANT VALLF-Y uvMES accordance with the standards of a Class A-2 survey as defined In the existing Code of P►a^ti:e for Standards of Accuracy of SO UTI4 W 1 NDSOR, C ON N. Surveys and Maps, adopted by the Connecticut Association of SCALE �..��• pare Io-2a-83 Lewd surveyom br. r ` 43--1q- 15�- Remo E. Hpyppa & Associates O Civil Engineers Glastonbury, Connecticut SS-cT(ON 3 t`OVEN S P AC S 65` 3 i �o�� E o o �. �.. j Ian I, // loll lo, AREA 27 888 5. 1- i Ile / 3 .• 1043 \ s ON ,/ ' C-1 NO 04 U') �i12 �/ .01 •p roe 10 lOb / 10 (o VOTE: Lot lines from slap on file in JE5 Town Clerk's Office entitled, "Plot Plan Section = Pleasant valley Howes �P- South Windsor, Conn." Scale 14- 40' Date �d A-20 -ONE Map No, 220-76 - Rev. - - by Re i no E. Hyyppa 6 Associates Glastonbury, CT. p�EPAR E C7 FOR I hereby ce+tffy thit this mao and survey were prepared iri PLE A54 NT VALLEY UQ M ES accordance with the standards of a Class A-2 survey as defined In the existing Code of Pra-h-_e for Standards of Accuracy of 50 UTN W I NDSO Q, ON N Surveys and Maps, adopted by the Connecticut Association of SCAT-E ,.,��• DATe 10-28-33 LOW surveyom Inc.. 43--1°1- i 5 AID _R 0 V E 0 Wl�!OSOR DATE: SIG.: aging E. Hyyppa As.oaiaf l OP Civil Engineers EN S r-c C E� Glastonbury, Connecticut SECTION .3 PAC E ) S 65 0 231,11 I7 1.30' A, \t)2 q 2 / ol 3 / ' oe i k 96 z// '' R l58 �// ,le b 159 \ '1 a AREA = 27. 888/ 5.F 15� � i ' a - 4 -qp ��/ i' 100 112- 10 iO4 ,tea �� •`t i r f 1p8 0��---- -- ►12 101 Fo t4 --twN LocAXED AS '-,ROWK1 IZ-IC -55 IM$ Lot lines from mpl an ad film Plot Plan 110 , ?own Clerkss 0[lirc , " section 8 Pleasant Valley Haines LPG South xindsor, coon." scale P- 401 Dab 3-28-83 A-20 MONE Map no. 220-76-1U 11,rr. — by Re1no E. Hyyppa a Associates Glastonbury. CT. pQrpw E O FOR 1 tweby certify thit this map and survey were papered in pLE4,54NT VALLEY WOME5 accordance with the standards of a Claw A-2 survey as defined In the wdoMng Code of Pra-lice for Standards of Accuracy of SOUTH W1NDSOR, CONN gwwys and Maps, adopted by the C+on mUcut Aeaodatbn of SALE 1"■�' p ATL'►o-2i3-B-3 SOW & VSYGM hm &4;/ 43 1°h-158 Shirley Wilhelm-CRS Approval Confirmation: Request No. 385456 Page 1 From: <clpsvc@nu.com> To: <WILHEL@SOUTHWINDSOR.ORG> Date: 11/30/0412:29PM Subject: CRS Approval Confirmation: Request No. 385456 Your approval of the following CRS Request has been successfully processed. CRS Work Request M 385456 House No: ;_109 Lot No: Street Name: JACQUES LN a Town Name: SOUTH WINDSOR, CT Inspector: CHRISTOPHER DOUGAN Approval Date: Nov 30, 2004 This e-mail, including any files or attachments transmitted with it, is confidential and intended for a specific purpose and for use only by the individual or entity to whom it is addressed. Any disclosure,copying or distribution of this e-mail or the taking of any action based on its contents, other than for its intended purpose, is strictly prohibited. If you have received this e-mail in error, please notify the sender immediately and delete it from your system. Any views or opinions expressed in this e-mail are not necessarily those of Northeast Utilities, its subsidiaries and affiliates(NU). E-mail transmission cannot be guaranteed to be error-free or secure or free from viruses, and NU disclaims all liability for any resulting damage, errors, or omissions. «««««««««««««««««««««««««««««««««««««««««««««««««««««««««««««««««««««« A DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT ApplicationZ TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT RO 1540 SULLIVAN AVENUE Bldg. Permit# 644-2511 ext. 230 0 Da a r Application must be printed or typed FEE SCHEDULE Location of Job: F $0-$1,000=$15.00 � Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT APPLICANT ADDRESS 1000 G I c, i ) Li P APPLICANT PHONE# gg O Yr N SE. OWNER h�/ "1 �/ 4 P C �^ ' S U 11 OWNER ADDRESS �`1 ��c � .e S Lq4 � So u-r , OWNER PHONE C ESTIMATED COST$ l !Inc, •� ; IS THIS A CONTRACT COST? _Yes X No FEE ENCLOSED$ �0 .p U 14, S0 0�� TYPE OF JOB: R C e<New Installation Al teration/Addition/Repair Revised 4/01/rMm APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑ EATING RESIDENTIAL • aC Cl COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE °F INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY ❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP. OUTSIDE 9 °F INSIDE OF DIFFERENCE��OF TOTAL HEAT GAIN(BTUH)39 jj b (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) CA l 1 H(- —I r Ny,4,,cr5 )- .Z TL-\ 1- �J 7Tu �- R,,.,< CA inn C_ Co A'd f^c e BTU n - a; TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 30:7081 0 c_ CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT* ` DATE O' O 1 Page 1 Residential Heat Loss and Heat Gain Calculation 1/4/2005 In accordance with ACCA Manual J Report Prepared By: Windsor Locks Heating&Cooling, LLC 28 Copper Dr. Windsor Locks,Ct.06096-2624 For: Neal Johnson 109 Jacques Lane South Windsor,Ct Design Conditions: South Windsor Indoor. Outdoor. Summer temperature: 70 Summer temperature: 99 Winter temperature: 68 Winter temperature: -4 Relative humidity: 55 Summer grains of moisture: 93 Daily temperature range: High Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 2,032.8 sq.tL 33,412 4,784 38,196 68,783 (3tons) First Floor 25,237 4,181 29,418 53,009 Sun Room 256 sq.fL 13,367 1,511 14,878 21,184 Dining Room 126 sq.fL 1,640 520 2,160 2,934 Living Room 216 sq.fL 3,535 711 4,246 6,685 Entry Foyer 120 sq.ft. 534 119 653 3,146 Kitchen 162 sq.ft 2,353 514 2,867 3,420 Bathroom 71 sq.ft 347 36 383 1,750 Family Room 258 sq.ft 3,461 770 4,231 13,890 Second Floor 8,183 609 8,792 15,812 Master Bedroom 214 sq.ft. 2,072 143 2,215 4,028 Walk in closit 43 sq.fL 335 0 335 878 Bathroom 64 sq.fL 456 36 492 1,067 Bathroom (2) 69 sq.ft. 476 36 512 1,113 Hall 76 sq.fL 120 0 120 199 Bedroom 2 214 sq.ft. 1,964 107 2,071 3,606 Bedroom 3 144 sq.fL 2,760 287 3,047 4,921 Whole House 2,032.8 sqA 33,412 4,784 38,196 68,783 (3 tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load Cabutab"are eat nw"ow actual loads may vary due to weather and earoW%w dHterenc m