Loading...
HomeMy WebLinkAbout108 PEPIN PL BLDG 1 s 1 INSPECTION FIELD SHEET 02/10/21 Printed by Middleton, Morgan 09 56 41 INSPECTION: 39776 FOOTING PERMIT: STATUS APPLICATION: 201100471 LOC: 244 SMITH STREET SOUTH WINDSOR PROPERTY ID: 83700244 OWNER: BRIN PETER J & JENNIFER J CONTRACTOR: REQUEST BY: PROJ DESC: CONVERT EXISTING TWO CAR GARAGE TO LIVING SPACE. ADD ON WORK ORDER: INSPECTOR: DOUG RESULT: PASS REQUESTED: 06/02/11 PRIORITY: SCHEDULED: 06/03/11 AM COMPLETED: 06/03/11 UNPAID FEES: 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS GEORGE ® 860-916-0749 ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 02/07/12 ROSE N/A B002 FOUNDATION 02/07/12 ROSE N/A B003 FRAMING (ROUGH) 08/17/11 DOUG PASS B004 INSULATION RICH ® 860-614-1693 02/07/12 ROSE N/A B005 FIREPLACE / CHIMNEY 02/07/12 ROSE N/A B006 WOOD / GAS STOVE 09/29/11 ROSE PENDING BO10 FINAL HALL SM &CO DETECTOR/FIRECAULK PENETRATIONS ON GARAGE WALL 09/29/11 ROSE FAIL BO10 FINAL GARAGE ATTIC ACESS TO BE SEALED AND SELFCLOSING 10/04/11 ROSE PASS BO10 FINAL RECHECK 02/07/12 ROSE N/A E001 ELECTRIC SERVICE 02/07/12 ROSE N/A E002 ELECTRIC UNDERGROUND 08/15/11 ROSE PASS E003 ELECTRIC ROUGH ROZ ® 860-242-7578 02/07/12 ROSE N/A P001 WATER HEATER REPLACEMENT 07/12/11 ROSE PASS P002 PLUMBING UNDERGROUND GENO ® 860-916-8180WATER TEST SAN UNDERGD PLBG 08/09/11 ROSE PASS P003 PLUMBING ROUGH l INSPECTION FIELD SHEET 02/10/21 Printed by Middleton, Morgan 09 56 41 WATER TEST RG.WASTE/VENTS,PRESS TEST H2O PIPES/TO VENT KITC 09/26/11 ROSE PASS P004 PLUMBING GAS TEST DOMINIC-539-2434//NEED TO SEAL PENETRATION FROM GARAGE WALL 202000598 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF OCCUPANCY DATE: 11/12/2020 �f e, FEE: GIS [D:70700108 y" Y . ` " ti: .r s _ ZONE: MUNIS APPLICATION# 201701346 THIS IS TO CERTIFY THAT ;�108 PEPIN PLACE,,: -UNDER"APPLICATION NUMBER 201701346 CONFORMS SUBSTANTIALLY T014TMi FOUIREMENTS OF,THE CONNEGTICUT,,EASIC BUILDING CODE AND THE ZONING REGULATIONS OF THE)`ow--N,OF...SOUTH WINDSOR--AND IS HEREBY APPROVED OF OCCUPANCY AS INDICATED BELOW: I ° APPROVED FOR OCCUPANCY r•GOTISTRUCT SINGLE FAMILY TOWNI-IOUSgWITH 2 BEDROOMS,2 1/2 `BATg' ,8-,ATTACHED 2.CAR GARAG AND,DECK. SPECIAL CONDITIONS NOTICE: IF THIS CERTIFICATE IS LOST OR DESTROYED,A DUPLICATE SHOULD BE OBTAINED IMMEDIATELY FROM THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: "n'°' BUILDING PFVICIAL 11/12/2020 9:09 AM ANY CHANGE OR EXTENSION OF THE USE HEREIN APPROVED REQUIRES A NEW CERTIFICATE OF OCCUPANCY DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# ii• <R •i �w2 644-2511 EXT.230 l '�D06S1 (Date) (Building Inspect r) Application must be printed or typed FEE SCHEDULE Location of Job: /D C- P-0 Ale, ie $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000- $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT I i APPLICANT ADDRESS S T 6r%. DGo�-- APPLICANT PHONE# ;> I(O W N S F,q OWNER V-177 OWNER ADDRESS O r �"'7 a✓. G/, CO) y OWNER PHONE C 1 ESTIMATED COST $ IS THIS A CONTRACT COST? I'YES NO FEE ENCLOSED$ IlOZ TYPE OF JOB: ?) 6 `FOR•CO 2!.New Installation _Alteration/Addition Repair �o 613y� Revised 12/22/11 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION? ,'YES ❑ NO O BUSINESS CURRENT USE AND OCCUPANCY O ASSEMBLY O MERCANTILE O EDUCATIONAL FUTURE USE AND OCCUPANCY O FACTORY O STORAGE ENGINEER'S NAME PHONE O GARAGE O MIXED USE ADDRESS (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION Ak,,V, ©L SIZE OF MAIN DRAIN NO.OF TOILETS STYLE GVOJ --'t NO.URINALS STYLE NO.OF BATHTUBS_� NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS / SIZE .3 AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ,W YES O NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK 'Y Y SIZE OF WATER MAIN / p SIZE OF WATER PIPING&RISER 3�{ WATER HEATER: TYPE L4 jyGTIL i C- MANUFACTURER DESCRIPTION OF WORK 1��• � l�w � f� � r11 Te cI N cr�� THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. -01 CONTRACTORS LICENSE NO. TYPE STA SIGNATURE OF APPLICANT CS DATE 1 a v APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074 (PHONE) 860-644-2511 EXT. 230 DEPARTMENT DECISION PERMIT NUMBER: APPLICATION IS HEREBY: /�06 6 T APPROVED: BLDG.PERMIT NUMBER: 3.� I. I OP Ig o o5 i DATE INSPECTOR LOCATION OF WORK: /OS A e RK,4ct APPLICANT: OWNER: / TYPE OF STRUCTURE: QlW BUILDING NAME: F�Bc��i�a�r? tf�� NAME: %��! ,fir//L®ex$_ 0ADDITION PHONE NUMBER: (PD` "// PHONE NUMBER ❑EXISTING BUILDING ADDRESS: ADDRESS: ,�'.S� TYPE OF USE: WI(OIDENTIAL ❑COMNIERCIAL ELECTRICAL INFORMATION: FURTHER DESCRIPTION OF WORK: TYPE OF INSTALLATION: i?JL=l1�1 SIZE OF SERVICE: -2,9'4 SIZE OF MAIN SERVICE: NUMBER OF METERS: NUMBER OF PANELS: NUMBER OF LIGHT CIRCUITS: ESTIMATED COST:S Z W12— NUMBER OF SWITCHES: NUMBER OF LIGHT FIXTURES: FEE ENCLOSED:S I J, NUMBER OF A/C CIRCUITS: -1 12l c FEE SCHEDULE:S1S PER S1,000 OF THE ESTIMATED COST. NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS$1.00 OVER (.26 CENT EDUCATIONAL FEE INCLUDED AS NUMBER OF OUTLETS: PART OF THE PERMIT FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: TYPE: E/ STATE: CT SIGNATURE OF APPLICANT:���G]�Jc'�x�fu.' DATE: a� a� APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074(PHONE)860-644-2511 EXT. 230 PERMIT NUMBER: DEPARTMENT DECISION APPLICATION IS HEREBY: f 8 b 0 13 y APPROVED: BLDG.PERMIT NUMBER: DIATE INSPECTO LOCATION OF WORK: 'Ci �� r`C ni n (iiGC 0j)i 6 APPLICANT: OWNER: TYPE OF STRUCTURE: !?NEW BUILDING NAME: ❑ADDITION NAME:/q11 �m�c7'cc�., n� +/PHONE NUMBER:0U 3 179-9171 �j 8 PHONE NUMBER: O CO �I1-�C)31 ❑EXISTING BUILDING ADDRESS:] ( ��rC{1,nE ( nC7 ADDRESS: f I U t3c�� 5+' (o r c n.-}c�r C-Q u2790 TYPE OF USE: x 6 3cil Wolc o-�I T C�c;iE / PRESIDENTIAL COMIAERCIAL // HVAC INFORMATION: 1 1 l FURTHER DESCRIPTION OF WORK:TYPE OF SYSTEM: 4HEATING �A/C J�n.S]l CL/I INI CAtl M CA, C C'l n C //J� C- HEATING: TOTAL HEAT LOSS(BTUH) °F (HEAT LOSS SHEET REQUIRED) DESCRIBE ALL HEATING EQUIPMMENT(INCLUDE MAKE AND MODEL NO.): 600ct rnQr, LI Cl.co c ►3T-u ESTIMATED COST:S AIR CONDITIONING: /' DESIGN TEMP:OUTSIDE 'F INSIDE T DIFFERENCE F° �/ FEE ENCLOSED:S / �-/V) TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET REQUIRED) 6 Z (P DESCRIBE TALL COOLING EQUPMENT(INCLUDE MAKE AND MODEL NO.): FEE SCHEDULE:S18 PER S1,000 OF THE ESTIMATED COST. Gd cam{ m o-n ;�To r) G-S X 1 3O r q j ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS SI.00 OVER. (.26 CENT EDUCATIONAL FEE INCLUDED AS PART OF THE PERMIT FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: C� c/ 7 TYPE: S STATE: SIGNATURE OF APPLICANT: DATE: �.�1 / & All American Heating & Air Conditioning South Windsor Woods 770 Boundline Rd. P.O. Box 6397 -Wolcott, CT 06716 Building 4 203-879-4928 - South Windsor, CT 06074 Sales Consultant: Job#: Unit 46/51 w/Bonus Date: 11/07/2016 System ! (Average Load Procedure) Design Conditions Location: Windsor Locks Bradley Field, Connecticut Elevation: 197 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 42* N Design Grains: 22 Summer: 88 75 Heated Area 1990 Sq.Ft. Winter: 8 70 Cooled Area 1990 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 2407.986 8707 2383 0 Windows 287.23 5342 5707 0 Doors 55.4112 996 416 0 Ceilings 813.502 1369 855 0 Skylights 0 0 0 0 Floors 832.354 3338 270 0 Room Internal Loads 0 4836 1462 Blower Load 1707 0 Hot Water Piping Load 0 0 0 Winter Humidification Load 0 0 0 Infiltration 9575 1044 1092 Approved ACCA Ventilation 0 0 0 MJ8 Calculations Duct Loss/Gain EHLF=0.115 ESGF=0.064 3361 988 386 AED Excursion n/a 0 n/a Subtotal 32688 18206 2940 Total Heating 32688 Btuh 10 kw of electric heat Total Cooling 21146 Btuh 62 Linear ft. of Hydronic Baseboard *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All competed calculations are estimates based on building use, weather data, and inputted values such as R-Values, window types,duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. Adtek AccuLoad Report Version 7.0.1 Page ALL AMERICAN HEATING • AIR CONDITIONING, INC. P.O. Box 6397 Wolcott, Connecticut 06716 Phone: (203) 879-4928 Fax: (203) 879-4920 CT License#303291 CT License#391792 CT License#203918 Date /'Z I /1 I,Jay Valimont Sr, hereby grant permission to S I'v /�Uc' to apply for a HVAC permit in the town/city of �sL�� �'�1 W n 4s" r using my S1-0391792 license for the address R) Ryj Sincerely, \01MI/vo Jay Val o t Sr President lime Im HEATING,PIPING&COOLING UNLIMITED CONTRACTOR JAY C VALIMONT SR PO BOX 6397 WOLCOTT,CT 06716-0397 LIC./REG NO. EFFECTIVE EXPIRES HTG.0391792 51, 09 01/2017 08/31/2018 SIGNED_ -- RECEIVED SITE COMPLIANCE CHECKLIST TOWN OF SOUTH WINDSOR,CONNECTICUT JUL 0 9 Z018 a 8 ) l a ***** FOR C OF O***** ►a d SQUiN w1noSOR PLANNING DEFT. ADDRESS tt LOT/UNIT# Reviewed by ")V (Engineering) CONTACT/DEV Y4' P)UU©� Date Reviewed ? ( p ve i PH#�36&� �— ��J� Reviewed by 1// (Planning) Date Submitted Date Reviewed V 9 / ro Denied Date Reviewed Approved/Denied(Health) As required in the Zoning and/or Subdivision Regulations,no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work,i.e.trees,shrubs, dumpsters,required parldng 4. Utility location; a. sanitary sewer/septic systems b. foundation drain C. electrical&telephone _ d. water e. otlxr GAS S. Sewer connection charge paid 6. Appropriate certification 7. Bonding /�J - 8. Planning&Zoning/ Inland Wetlands Considerations a. Lighting b. Signage Freestanding Wall C. Fee in lieu of Open Space COMMENTS: // r s/engineering/molloy/site compliance cheddist S � � �'.� cvw.rmvr uwr.rornr corwr () SANTAT --• p. r ! t A _71 \ 'S + 1 :Sd SI \ _a' O /� rx.lAxa/M FArw•� a?/ 1 <\ .s .Lr :N ,�i ', L- `d` �a �� .p�! \ 6 / �. •: l a.!ao rc u 6 41+ � Sl • t bb � — �c` r� 0. 41 0 C / lo GAZEBO ^. A/C UNIT / a ro..vu�. r........r i: r V. � �' �• Q G� (mil � �m.c`M'wr�io6v r�w'•�wr wrwr..ro rGi _ o` Qr• � �J \�' � e \ // / iao"�ero."i u wo'e"w.""way war�ar`a.r ri.i��r I b r�ee¢18rele� t ncwwE ioweavwu/iwKtino.a�sr «i"'°'tw .�$MN /N 59 f-V � �' 1 �J •h // 4 7 }Sat / LPG)k)V • 1 • V pIPPN'OLD or aLNT � 'l �� + \ y�� \ \��JO'RLp • CULVERT .saP fL:55.55 —/-62- LOCArrav cr GS� / \ \ FE 30'RCP ----RIP-RAP 1 `6Qe r r\Nan or a,ENr f \\ \ \\ 1W58.15 F _ .i..u.MP..t.......gW.I.Y SCALE 0 to 2a +a .....r,.r...,.�. ...®... T-20' mmr-�e ,v-a Electric # APPLICATION FOR BUILDING PERMIT Plumbing# ,Q g P -� HVAC# _-- -_ --- ePtrl Tkye- Date: 0 d Sprinkler# I 1 Estimated Cost $ w� FINAL APPROVALS Permit Fee $ a� Building COMPLETE RED BOXED AREAS Occupancy Fee $ 3D Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit ► SIGN ON REVERSE SIDE t Appr.forCO. Total Fee $ t, TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ -00 1344 The undersigned hereby applies to do work according to the following: Applicant 1Z 5j 1 f ocationof Work 10Y Peam Q.L&, Lot No. _ Applicant's A ess 0 r Tel # � f'�/' C11� �1 Town rn t l C� Zip Lic.# "6 01 Owner S Architect Q N Owner's Address Architect's Address k&&ure Zip lD Zip afn Sq. Ft. New Area: 1 st FI. 4 112nd FI. 60 4 3rd FI. �g 1 Total New Area I8a Purpose of this permit o ch l �� �n u� w 4k 1 Car O e l� &VOL 1� City Water Well J Septic System ] Sewer .20I-7013Tso Ins: HO SP Cert. Area Basement Garage Approved by Date Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines, side yard lines,and required distances from all other zones and is located in which t is building and its u is allowed. Signed — / I hereby apply for a Certificate of Occupancyr th work d rib in this application for the permit. Signed _ DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS INSPECTION FIELD SHEET 04/19/22 Printed by Middleton, Morgan 15 11 21 INSPECTION: 130408 FINAL PERMIT: STATUS APPLICATION: 201701346 LOC: 108 PEPIN PLACE SOUTH WINDSOR PROPERTY ID: 70700108 OWNER: T & M BUILDING CO INC CONTRACTOR: T & M BUILDING CO. , INC. 860-883-5910 REQUEST BY: PROJ DESC: CONSTRUCT SINGLE FAMILY TOWNHOUSE WITH 2 BEDROOMS, 2 1/2 WORK ORDER: INSPECTOR: WEAR RESULT: PASS REQUESTED: 11/10/20 PRIORITY: SCHEDULED: 11/10/20 COMPLETED: 11/10/20 UNPAID FEES 00 Date Time MILEAGE: .00 TIME: TRAVEL ONSITE COMMENTS: CO Inspection ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 10/16/17 ROSE PASS B001 FOOTING B002 FOUNDATION 04/06/18 ROSE PASS B003 FRAMING (ROUGH) ROSE B004 INSULATION B005 FIREPLACE / CHIMNEY BO10 FINAL 04/04/18 ROSE PASS E001 ELECTRIC SERVICE OK TO RELEASE TO EVERSOURCE 11/13/17 DOUG PASS E002 ELECTRIC UNDERGROUND 04/10/18 ROSE PASS E003 ELECTRIC ROUGH 04/06/18 ROSE PASS H003 HVAC ROUGH DUCTWORK 11/15/17 ROSE PENDING P002 PLUMBING UNDERGROUND PRESS TEST METHOD PROHIBITED 11/16/17 ROSE PASS P002 PLUMBING UNDERGROUND WATER TEST ON UNDERGD DRAINS 02/28/18 ROSE PASS P003 PLUMBING ROUGH PARTIAL /CONTR. TO FINISH TESTING & SUPPORT OF WASTE PIPE 03/12/18 ROSE PASS P004 PLUMBING GAS TEST APPROVED FOR METER SERVICE INSPECTION FIELD SHEET 04/19/22 Printed by Middleton, Morgan 15 11 21 07/24/18 LIPE PASS Z003 CO PLANNING INSPECTION 44 `�� ��'� �• RECEIVED 1540 SULLIVAN AVENUE•SOUTH WN=k,CT 06074 NOV 12 2020 TELEPHONE(860)644-2511 South Windsor BuBding Dept AN A& CONCERNING CONCRETE FOUNDATIONS: Sec m 1(P6lic Act No.16-45)(IOW}Mffccarm Oftber 1,?Alb}Pf=to the bm==of a Caffmft of Ooompmy for a aaw rem&rdial at camm=ial bum for which a oa®arete foaa&dm was inatalied on or after Oefober i,21rh do qp 1mat"mvide the Banding offieW wig daamx nmtkx offfic nama of tha mdividval or entity that awplw go came ad tba creme of the iadivulaal or easy fat b allod to Mecsete: Hof aach doh"be od at&e rya of ft office of the Bm'lmag Mid for not im (A Yam Please fM the infor=doa m and a6mit to the Btdlding Department SCANNE-D Date of Wiest recetved/f�d: �� /l o?OB� Prof esc#l�ocn�on: 5o u}� tt9�vats or Gs90 S Job decutdow lh, 1 Do"' �en In Plate, OIA41 �J Nam ,/� cCQ3xCRJGE�3�s II�ST'AIaLER e:_ Clrt�tlLT1LuT� d/�!X Name: J!4 D✓ � OkS (Pkase Pt#at) (Please Psird) Ate:10..irikaAW La G Addnmm- o 0 r t n 07.1 5oag OmAlp ' 4"7y rham coatut �'6D• 6 yy- ifannt C.o �iK Ol�is�4N�f JG (Please Ftrnt} Addrm: a Meek 31, Phoudcasmact: S6�• S/p g•9�.?� err 0 67�0 &•ma8.• 6ob� 5'favc�►U�?,r 7'auaQNl.coO? ,WORK • CompanyAddress 110 Brook Stnx4 400 Pleasant Valley Road Torrington CT 06790 South Windsor CT Type of WE IMM ■■ i■■■ ■ ■�N■MIN ■■■■■N MIN ■!■ M■■■■■�■ ■■■■MIN■MINIM■■MIMI■MINIM■■ s■N■MI■■o■■■■■■■■■■■■■■==MINIM■ MIN■■�■�■!■■■�■MI■!MIMI■IMIMIMIlIMIIM�!N `il■ 0`E3■■`�■■ice■MI`DIMN`'�7MIN�� ■■■NMI■■IMIMIMMINNIM■■NNMIMI■NMIMINIM■■■ N■■MIN■■■■■■■■■MIN■■MI��■■NMINfIMINIM ■■■■ ■ IO N ■MINIM■■■ ■■MINIM■■■ ■■ ■■■MIN■NMINN■■■■q MEN■■■■■■MI�■■MIN■MIN■MIN■ION MIN MIN■MIN ■■■■MIN■■MI■NNNMI■■MIN■MIMI■NNN�■MI■ ■ MIN■■N■N■■■MIN NMI■■■■MINMIN■■NMIMI■■�■ ■ ■�■r ■ NONE MEN IN SOME 0M SOME ■ _�-1M�� ■ _ IN WORK SITE SHEET DATE:3=2018 Building . .. Delivery Address I 10 Bmok Street 400 Pleasant Valley Road Tonington CT 06790 South Windsor CT • • . • • f ©-NONE MENNEN --_- � l • i S■M■■EEMO■■ME■■O■ME■■A■■■■ M■■ ■■■MMM ■■■■■■1 MENENO mom ■ M ■■■■■ 00101INNEEME ■■■■■M■ ■■ ■■ ■■■■■■ MM■■■o■ ■ M=MOMS■■■■■■OSMOSESr.EMM ■■■ ■■■■ :.�i■■ M■r�■■RNMEM■■■■■■■ ■■■■��■■WM■■■■__ MMKIENEM■■■ ■E■ ■■■E�M ENOM■NEE■SAEOMO■■■■ ■■ ■■SOME■■■■■■■■■■■■■■■■■■■■■■■■ EO■■■EM■SEEM■ ■MMM■E■MOMS■MMM■ ■■M■O■MM■■■■M=MMMME■■■O■■■■MSM■ ■■■■■S■OEM■■■■■MNMM ■■■■iM■■■■■■■ ■■ ■■■■■■■■■■■ M■■SSOMMO■M■ NONE IN IMME NONE ■��� ■� NONE NO _IMINIME ��IN �� ATTIC AND CAVITY WALL CARD ® WE[MN Jet Stream ULTRA Blowing Insulation t:r::Ec 7DAlD*r,Yt f1 �108 Pe)in Iw HOMEOWNERS NAME: T'�[`M gt p-Go � !OB SITE ADDRESS: UnstT— !o CITY: STATE: Ot_ ZIP: V �� BUILDER'S INSULATION STATEMENT Jet Stream ULTRA has been installed in conformance with the included recommendations to provide a thermal resistance of: LOCATION R-VALUE NO.OF • COVER Attic Area R- 3$ �O at 13 inches ago sq.ft Sloped Ceilings R- at inches sq.ft Walls R- at inches sq.It Floors(over an R- at inches sq.ft unheated crawl space Crawl Space R- at inches sq.ft Perimeter THERMAL PERFORMANCE EQUIPMENT REQUIRED The stated thermal resistance(R-value) is provided by installing To achieve labeled R-value,this product must be applied with the required number of bags per 1,000 square feet of net a pneumatic blowing machine and a corrugated hose with a area,at not less than the labeled minimum thickness(per the minimum 0.25" internal corrugation, a minimum length of 150' manufacturer's instructions). Failure to install both the required and a diameter of at least 3'.Coils in the hose should not be number of bags and at least the minimum thickness will result in less than 36' in diameter.The recommended feed rate is 15-25 lower insulation R-values. IbsJmin. For closed cavity applications,fabric or netting must III Field blending of this product with other loose fill insulation be applied. or application of this product in conjunction with adhesive or binder systems may affect its thermal performance and is not recommended by the manufacturer. CONTRACTOR'S SIGNATURE: + DATE: COMPANY: — ADDRESS: 4 5 Cr-oU� _ � `� PHONE:.Zo3—Z35_—RT? C'foy,SO •' !V#in.Eagst � test Min.vveight/ ,ritial tnstanied Min.settlAm 1,00 %*ax.Cover F q. TfIkkttess Ttoickn Number of bags per i Contents of this Werght per square To cota!n a thermal 1,000 square feet foot of installed Installed insulation Installed insulation resistance of: of net area should bag should not insulation should should re'be les than: should not be less than: not be less than: cover more than: not be iess than: R-60 29.7 33.6 sq.ft. 0.952 '.bs. 19.750' 19.750, R-19 23.5 42.5 sq.ft. 0,753!bs. 16.375' 16.375' R-44 20.9 47.8 sq.ft. 0.670 lbs. 14.875' 14.875' R-38 17.8 56.2 sq.ft. 0.569 lbs. 13.000' 13.000' R-30 13.6 73.3 sq.ft. 0.437 lbs. 10.375' 10.375' R-26 11.8 85.0 sq,ft. 0.377 lbs. 9.125' 9.125' R-22 9.8 102.2 sq.ft. 0.313 lbs. 7.750' 7.750' R-19 9.4 119.3 sq.ft. 0.268 lbs. 5.750, 6.750' R-13 5.7 175.3 sq.ft. 0.183 Its. 4.750' 4.750' R-11 4.7 210.8 sq.ft. 0.152 lbs. 4.000' 4.000' Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. Coverage and installation data were determined using a Volu-Matic'II blowing machine in third gear with 13'gate opening,2.5-3.0 PSI air pressure, 150'of 3'diameter internally-corugated hose.Volu-Matic II s a registered trademark of CertainTeed Corporation. •"R"means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-value,it is essential that this insulation be installed properly. If you do it yourself,get instructions and follow them carefully. nstructions do not come with this package. **Based on Third Party 10-year settling study,the predicted settlement over a 20-year period would 5e 1 percent or less.This amount of settling is thermally insigmfcant. Therefore,the Installed and settled thicknesses are effectively the same. • Va:uE* Bags11,000 Sq.R. 1 Max-Coverage/Bag gttt/Sq. Number Q-f bags per i "'TO D6tai►t'a Contents of this bag 'Weight per square fit 1,000 sc'uare feet of ; insulation net area should rot should not cover of installed insulation resistance of:- more than: should not be less than: be less than: j 2'x 4' 3.50' R-155 1.8 PCF 16.4 61.0 sq.ft. 0.525 lbs. 2'x 6' 5.50' R-23 1.8 PCF 25.8 38.8 sq.ft. 0.825 lbs. 2'x 8' 7.25' R-31 1.8 PCF 34.0 29.4 sq.ft. 1.088 lbs. 2'x 10' 9.25' R-39 1.8 PCF 43.4 23.1 sq.ft. 1.388 lbs. Check with your Knauf Insulation Territory Manager to ensure information is current. KNAUF INSULATION,INC. One Krauf Drive The chemical and physical properties of this product represent average values Shelbyville. IN 46176 determined in accordance with accepted test methods.The data is subject to normal manufacturing variations.The data is supplied as a technical service and s subject Technical Support to change without notice.References to numerical flame spread ratings are not intended (317)398-4434 ext.8727 to reflect hazards presented by these or any other materials under actual fire conditions. info,us@knaufinsulation.com This product is covered by one or more U.S.and/or other patents. See patent www.knaLifngahamgrica.com/patents 01-20 Visit knaufnorthamerica.com to learn more. 0 2020 Knauf Insulation, Inc. • BUILDING LEAKAGE TEST SCANNED Date of Test: 7/11/2018 Test File: 108 PEPIN PLACE Customer: BOB Technician: V CASTELLON Project Number: Building Address: 108 PEPIN PL SOUTH WINDSOR, CT Test Results 1 Airflow at 50 Pascals: 936 CFM50 (50 Pa= 0.2 w.c.) 2.85 ACH50 X PASS 2. Leakage Area: 51.5 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 73.6 Exponent (n) =0.650 (Assumed) 4. Test Settings: Test Standard: RESNET One-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test V CASTELLON 203-903-7387 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 42.5 CFM 0.13 ACH 10.6 CFM per person 2. Estimated Design Infiltration Rate: Winter: 60.1 CFM Summer: 47.3 CFM 0.18 ACH 0.14 ACH Cost Estimates 1 Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline(based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 51.9 CFM Base Rate: 51.9 CFM • DUCT LEAKAGE TEST RESULTS SCANNinwx Date of Test: 7/11/18 Test File: 108 PEPIN PLACE Test Performed For: BOB Phone V CASTELLON 203-903-7387 Test Results 1 Test Type: Total Leakage (Duct Blaster Only) 2. Test Pressure: 25.0 Pa 3. Measured Duct Leakage: 51.0 CFM (9.6 sq. in.) 4. Duct Leakage as a Percent of System Airflow: 5. Duct Leakage as a Percent of Building Floor Area: 2.3% X PASS Additional Information Duct leakage is often one of the largest sources of energy loss in a house. Leaky supply ductwork causes expensive conditioned air to be lost before it can be delivered to the house, forcing your system to run longer to keep you comfortable. Leaky ductwork can seriously degrade indoor air quality by pulling pollutants and irritants directly into your house. Leaky return ductwork can also pull moisture into your home, making it feel uncomfortable even when the air conditioning is running. SCANNED 202000598 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF OCCUPANCY DATE: 11/12/2020 FEE: GIS ID: 70700108 ZONE: MUNIS APPLICATION # 201701346 THIS IS TO CERTIFY THAT 108 PEPIN PLACE UNDER APPLICATION NUMBER 201701346 CONFORMS SUBSTANTIALLY TO THE REQUIREMENTS OF THE CONNECTICUT BASIC BUILDING CODE AND THE ZONING REGULATIONS OF THE TOWN OF SOUTH WINDSOR AND IS HEREBY APPROVED OF OCCUPANCY AS INDICATED BELOW: APPROVED FOR OCCUPANCY : CONSTRUCT SINGLE FAMILY TOWNHOUSE WITH 2 BEDROOMS,2 1/2 BATHS,ATTACHED 2 CAR GARAGE, AND DECK. SPECIAL CONDITIONS NOTICE: IF THIS CERTIFICATE IS LOST OR DESTROYED,A DUPLICATE SHOULD BE OBTAINED IMMEDIATELY FROM THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: _ OCCUPANCY GROUP: BUILDING PFfICIAL 11/12/2020 9:09 AM ANY CHANGE OR EXTENSION OF THE USE HEREIN APPROVED REQUIRES A NEW CERTIFICATE OF OCCUPANCY i '• �. r,.. �C �x ._ � r� � y.