Loading...
HomeMy WebLinkAbout108 DEBBIE DR APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT ' 1 APPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 ` e a 12 1z— Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT c h Z- / S z d'u 1 c CA C C. APPLICANT ADDRESS 17 n S L. .2 f�► d C c, 1 APPLICANT'S PHONE# OWNER , 2::: 1, A%0W N SFN< OWNER ADDRESS J D PJZ O OWNER PHONE ESTIMATED COST$ C � IS THIS A CONTRACT COOST? Yes No FEE ENCLOSED$ ) S TYPE OF JOB: 12 4'L OR,C New Installation Alteration/Addition/Repair 7°''7 6OS3� Revised 03/05/10 APPLICATION FOR HVAC PERNUT(Continued from ieverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑ HEATING ❑ RESIDENTIAL C A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING (3 STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT.HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY'APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY f INPUTBTUH)- NET RATING(OUTPUT-BTUH): TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION:❑ ,INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO. TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCO ANY APPLICATION) FURTHER DESCRIPTION OF WORK c e 7 0 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT - �_ DATE Date:Pro ect Summary wright5oft' � ' Date: May 15,2017 Entire House By: FOREMOST MECHANICAL SERVICESXLC 306 SCANTIC RD,EAST WINDSOR,CT 06088 Phone:860-7584218 Email:foremostmechllc@gmail.com Prooect Information For: KARLA STREETER 108 DEBBIE DR, SOUTH WINDSOR, CT 06074 Notes: Design Information Weather: Hartford Bradley Intl AP, CT, US Winter Design Conditions Summer Design Conditions Outside db 8 OF Outside db 88 OF Inside db 68 OF Inside db 75 OF Design TD 60 OF Design TD 13 OF Daily.range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 38353 Btuh Structure 27173 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 38353 Btuh Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipment sensible load 25379 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 1 (Average) Structure 2844 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2 2016 2016 Equipment latent load 2844 Btuh Volume(ft3) 18144 18144 Air chan�gges/hour 0.70 0.33 Equipment total load 28223 Btuh Equiv.AN(cfm) 211 100 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make American Standard Trade Trade AMERICAN STANDARD Model Cond 4A7A4043L1 AHRI ref Coil TEM4AOC42S41++TDR AH R I ref 7550183 Efficiency 80AFUE Efficiency 13.0 EER, 15 SEER Heating Input 0 Btuh Sensible cooling 28700 Btuh Heating output 0 Btuh Latent cooling 12300 Btuh Temperature rise 0 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,L wri htSoft' 2017-May-1511:20:41 9 Right-Suite®Universal 2017 17.0.21 RSU19651 Page 1 AC K Projectt.rup Calc=MJ8 Front Door faces: N AED Assessment Job: Wrightsoft, Date: May 15,2017 Entire House By: FOREMOST MECHANICAL SERVICES,LLC 306 SCANTIC RD,EAST WINDSOR.CT 06088 Phone:860-758-4218 Email:foremostmechlk@gmail.com Project • • For: KARLA STREETER 108 DEBBIE DR, SOUTH WINDSOR, CT 06074 Design Conditions Location: Indoor: Heating Cooling Hartford Bradley Intl AP, CT, US Indoor temperature(OF) 68 75 Elevation: 180 ft Design TD (OF) 60 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 44.6 26.8 Dry bulb(OF) 8 88 Infiltration: Daily range(OF) - 21 ( M ) Wet bulb(OF) - 72 Wind speed (mph) 15.0 7.5 Test for Adequate • • Diversity Hourly Glazing Load 20.000-- 18'ODD- 16.000-- 14.000-- 12,ODD— s` 10, 8, 6. 4, 2. 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 29.7%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh c wri htsoft` 2017-May-1511:20:41 9 Right-Suite®Universal 2017 17.0.21 RSU19651 Page 1 Projectl.rup Calc=MJ8 Front Door faces: N }+-wrightsoft• Right-M Worksheet Job: Entire House Date: May 15,2017 FOREMOST By: 306 SCANTIC RD,EAST WINDSOR,MAOnEeS860-M 758-4218 Email:foremostmechllc@gmail.com 1 Room name Entire House Room2 2 Exposed wall 240.0 ft 108.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 42.0 x 24.0 ft 5 Room area 2016.0 fix 10W.0 ft2 Ty Constriction U-value Or HTM Area (ftj Load Area (ftj Load number (Sh"I't-F) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 1q1 12C-Osw 0.091 n 5.46 1.79 216 192 1048 343 0 0 0 0 �G 1Dc2ow 0.570 n 34.20 18.35 24 0 821 440 0 0 0 0 W✓ 12C-Osw 0.091 a 5.46 1.79 756 651 3554 1164 378 297 1622 531 T-0 1 Dc2ow 0.570 a 34.20 60.23 105 0 3591 6325 81 0 2770 4879 11 W/ 12C-Osw 0.091 s 5.46 1.79 432 405 2211 724 216 201 1097 359 �-G 1 Dc2ow 0.570 s 34.20 31.85 27 0 923 850 15 0 513 478 1qJ 12C-Osw 0.091 w 5.46 1.79 756 607 3314 1085 378 301 1643 538 L�-0G 1Dc2ow 0.570 w 34.20 60.23 128 0 4378 T710 56 0 1915 3373 11 DO 0.390 w 23.40 9.61 21 21 491 202 21 21 491 202 R 12C-Osw 0.091 - 5.46 0.00 216 195 1065 0 216 195 1065 0 �--D 11D0 0.390 n 23.40 9.61 21 21 491 202 21 21 491 202 C 166-21ad 0.044 - 2.64 2.12 1008 1008 2661 2136 0 0 0 0 6 c AED excursion � 0 565 Envelope loss/gmn 24550 21191 11608 99T7 12 a) Infiltration 13804 1461 6212 658 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 4 920 2 460 Appliances/other 3600 2100 Subtotal(lines 6 to 13) 38353 27173 17820 13195 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 38353 27173 17820 13195 15 Duct loads 0% 00/0 0 0 -0%I 0-/.l 01 0 Total room bad 38353 27173 17820 13195 Air required(cfm) 1367 1367 635 664 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsofC 2017-May-1511:20:41 Right-Suite®Universal 2017 17.0.21 RSU19651 Page 1 Projectl.rup Calc-MJ8 Front Door faces: N - -wrightsoft' Right-J®Worksheet Job: Entire House Date: May 15,2017 By: $FOERR�E/MCOS-TLLMCECHANICAL 306 SCANTIC RD,EAST WINDSOR,CT�6088�fionEeS8511-758-4218 Email:foremostmechllc@gmail.com 1 Roan name Room4 2 Exposed wall 1320 ft 3 Roan height 9.0 ft heat/cool 4 Roan dimensions 420 x 24.0 ft 5 Room area 1008.0 f12 Ty Constriction U-value Or HTM Area (ft2) Load Area Load number (Btuhlft-F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 %E-C 12C-0sw 0.091 n 5.46 1.79 216 192 1048 343 1 Dc2ow 0.570 n 34.20 18.35 24 0 821 440 vN 12C-0sw 0.091 a 5.46 1.79 378 354 1933 633 T—G 1 Dc2ow 0.570 a 34.20 60.23 24 0 821 1446 11 W/ 12C-0sw 0.091 s 5.46 1.79 216 204 1114 365 �C 1Dc2ow Q570 s 34.20 31.85 12 0 410 382 12C-Osw 0.091 w 5.46 1.79 378 306 1671 547 1 Dc2ow 0.570 w 34.20 60.23 72 0 2462 4337 11 DO 0.390 w 23.40 9.61 0 0 0 0 R 12C-0sw 0.091 - 5.46 0.00 0 0 0 0 --D 11DO 0.390 n 23.40 9.61 0 0 0 0 C 166-21ad 0.044 - 2.64 212 1008 1008 2661 2136 6 c)AED excursion 585 Envelope loss/gain 12941 11214 12 a) Infiltration 7592 804 b) Roan ventilation 0 0 13 1ritemal gains: Occupants 230 2 460 Appliances/other 1500 Subtotal(lines 6 to 13) 20533 13978 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 20533 13978 15 Duct loads -0% 0% 0 0 Taal roan load 20533 13978 -T Air required(cfm) 732 703 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 41 wrigtrtsofr Right-Sufte® Paa ge Universal 2017 17.0.21 RSU19651 2017-May-15 11: ge 2 Projectl.rup Calc=MJB Front Door faces: N Level 1 z1367 cfm 00 Job #: FOREMOST MECHANICAL SERVICE... Scale: 1 : 89 Performed for: Page 1 KARLA STREETER 306 SCANTIC RD Right-Suite®Universal 2017 108 DEBBIE DR EAST WINDSOR,CT 06088 17.0.21 RSU19651 SOUTH WINDSOR, CT 06074 Phone: 860-758-4218 2017-May-15 11 20 49 Projectl rup foremostmechllc@gmail.com N Level 2 Room3 Room2 9166&66&66(4n166 drn Job#: FOREMOST MECHANICAL SERVICE... Scale: 1 89 Performed for: Page 2 KARLA STREETER 306 SCANTIC RD Right-Suite®Universal 2017 108 DEBBIE DR EAST WINDSOR,CT 06088 17.0.21 RSU19651 SOUTH WINDSOR,CT 06074 Phone:860-758-4218 2017-May-15 11:20:49 foremostmechllc@gmail.com Projectl.rup N Level 3 Room4 183[4n183[4n18314M83 cfm Job #: FOREMOST MECHANICAL SERVICE... Scale: 1 : 89 Performed for: Page 3 KARLA STREETER 306 SCANTIC RD Right-Suite®Universal 2017 108 DEBBIE DR EAST WINDSOR,CT 06088 17.0.21 RSU19651 SOUTH WINDSOR, CT 06074 Phone: 860-758-4218 2017-May-15 11.20 49 Projectl.rup foremostmechllc@gmail.com Duct System Summary Job: -f - wrightsoft* Date: May 15,2017 Entire House By: FOREMOST MECHANICAL SERVICES,LLC 306 SCANTIC RD,EAST WINDSOR,CT 06088 Phone:860.7W 4218 Email:foremostmechllcagmail.com Project • • For: KARLA STREETER 108 DEBBIE DR, SOUTH WINDSOR, CT 06074 Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 1367 cfm 1367 cfm Total effective length(TEL) 0 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk Room2 c 3301 159 166 0 0 OX 0 ShMt 0 0 Room2-A c 3299 159 166 0 0 OX 0 ShMt 0 0 Room2-B c 3299 159 166 0 0 Ox 0 ShMt 0 0 Room2-C c 3299 159 166 0 0 Ox 0 ShMt 0 0 Room4 h 3495 183 176 0 0 Ox 0 ShMt 0 0 Room4-A h 3494 183 176 0 0 Ox 0 ShMt 0 0 Room4-13 h 3494 183 176 0 0 Ox 0 ShMt 0 0 Room4-C h 3494 183 176 0 0 OX 0 ShMt 0 0 TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb2 OX 0 1367 1367 0 0 0 0 Ox 0 ShMt ,. wrightsofC Right-Suite®Universal 2017 17.0.21 RSU19651 2017-May-15 11:20:41Page 1 AC:;k Projectt.rup Calc=MJ8 Front Door faces: N APPLICATION FOR:ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 1�1 ppt 32 AP UBWI ��r 1540 SULLI VAN AVENUE. 644-2511.ext. 230Bldg:Permit# Date Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 0 p c b h(C ID 2 c e. Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS —moo J.T ff . t„J n✓ S �.T- a 6 0 APPLICANT'S PHONE# OWNER /�G tj 2(, P� �T P e e T e '�Ow N S�q< OWNER ADDRESS /Q e}�h ( ��IZ ✓c SUVr t O c i C`� 64ZE . O OWNER PHONE ?G.a C ESTIMATED COST$ e T d � IS THIS A CONTRACT COST? f�Yes No FEE ENCLOSED-$. / TYPE OF JOB: �q S dSOR-COS New Installation tion/Addition/Repair. p 1j 6t>,5 Revised 03/05/10 APPLICATION FOR ELECTRICAL PERNUT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑. ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE. ❑ FACTORY ❑ STORAGE ADDRESS ❑ GARAGE . ❑ MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD. SIZE OF SERVICE SIZE OF MAIN CONDUCTORS .: NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FUCTURES NUMBER OF HEAT CIRCUITS NUMBEROF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST-BE'SUBMITTED. DESCRIPTION OF WORK f,/C "-A/ fik u'k 4- 7- -v7,--S) O'Q— WlPf THE UNDERSIGNED NEARBYAPPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE S- f2- ( 7 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Applic s h TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT AP ROv 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date 8jilding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. —71 APPLICANT APPLICANT ADDRESS fix.. APPLICANT PHONE# �W N SFq OWNER C,c OWNER ADDRESS Ob OWNER PHONE v C ESTIMATED COST$ IS THIS A CONTRACT CO ? Yes _No FEE ENCLOSED$ .S O 0 14 �� TYPE OF JOB: OR CO _New Installation 1414 ✓Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑YES,4NO RES IDEN TIAL BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE❑ EDUCATIONAL FUTURE USE AND OCCUPANCY ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑GARAGE ADDRESS O MIXED USE (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE NO. URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES NO. OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES ❑NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 2-0.3S"1 2' ►C'- ) C—N CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT ���, Q \��M.4 DATE �k A 01 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: co,�r BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# ` Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: F $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT APPLICANT ADDRESS APPLICANT PHONE# � `�/,�� O W N S F,q OWNER OWNER ADDRESS /. # OWNER PHONE C ESTIMATED COST$ IS THIS A CONTRACT COST? J Yes _--3d�-- A' � „^o �► ! �� FEE ENCLOSED$ /� TYPE OF JOB: 1q SOR'C0 New Installation teration/Addition/Repair ` 37 1 Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE F BUILD- IS THIS APPLICATION ASSOCIATED WITH A ZING BUILDING PERMIT APPLICATION? ❑YES ❑ NO RESIDENTIAL CURRENT USE AND OCCUPANCY ❑BUSINESS ❑ASSEMBLY FUTURE USE AND OCCUPANCY ❑MERCANTILE ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑ YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROV D 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# �- S• 88' Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: log -- $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Alell d //17M )e Il I C PS APPLICANT ADDRESS APPLI PHONE# w N s owN0#qf- LLMnrutl O �4< OWNER ADDRESS 10 P 6&G U SoA, o 4- O o OWNER PHONE 9&O—644- gA C _ ESTIMATED COST$ &O ). O 0 �.� IS THIS A CONTRACT COST? Yes _No FEE ENCLOSED$ OO TYPE OF JOB: � 3� O� dsOR•C�� _New Installation 0 Alteration/Addition/Repair APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING SIDENTIAL ❑ A/C ❑ COMMERCIAL ❑VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESvo �C�RIBE AL HE T Q El �INC I A M D/ 2!3DELON ) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION :❑ INSIDEO OUTSIDE CAPACITY `(GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) /� FURTHER DESCRIPTION OF WORK C4 1�ti il(��W�t�P►, HQ�(`t�/� THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3C)S03A S-1 cl-r CONTRACTORS LICENSE NO TYPE STATE Q' SIGNATURE OF APPLICAN DATE U 6 A O E L LD CORPORATE OFFICE P.O.BOX 548,WINDSOR LOCKS,CT 06096 Plumbing,Electrical,Heating,Cooling&Home Heating Oil HOME SERVICES To Whom This May Concern: Aiello Home Services authorized Peter Butler, Ray Page,Russell Horrocks, or Linda Dawson-Hayes,Tony Esposito to pull permits for our company for any plumbing, heating or air conditioning replacements or new installations. If you have any questions please call our office at 860-292-2600. This letter is for a permit for the property located at: 105`���6 r . l Soy ��4,>,` soti{ C ' 06 0 Z� Homeowner: OLLV MOeld Permit Fee Amount: $ ,0 P Sincerely, Michael Jezouit President Windsor Manchester Enfield Avon New Britain Glastonbury Middletown (860)688-4881 (860)648-2397 (860)745-1783 (860)673-7377 (860)225-5523 (860)633-3108 (860)346-8144 FAX(860)292-2690•TOLL FREE 1-888-956-4455•CT Lic.P1-203350 9 S1-303032•E1-191819 Page 1 2/25/2008 Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Registered To: Aiello Plumbing Heating and Air Conditioning For: Morin Bob&Molly 108 debbie dr south windsor, Ct 06074 Design Conditions: Windsor Locks,Bradley Field Indoor: Outdoor: Summer temperature: 72 Summer temperature: 95 Winter temperature: 70 Winter temperature: -6 Relative humidity: 50 Summer grains of moisture: 93 Daily temperature range:Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 2,612.3 sq.ft. 27,582 3,184 30,766 82,257 (2.5 tons) Lower Level 4,437 525 4,962 11,705 All Rooms 574 sq.ft. 4,437 525 4,962 11,705 First Floor 12,059 1,628 13,687 46,359 Laundry 45 sq.ft. 575 55 630 1,190 Dining Room 156 sq.ft. 1,167 276 1,443 4,589 Kitchen 266 sq.ft. 4,567 469 5,036 7,835 Family Room 234 sq.ft. 2,504 221 2,725 22,436 Living Room 221 sq.ft. 2,707 414 3,121 7,337 foyer 100 sq.ft. 539 193 732 2,972 Second Floor 11,087 1,030 12,117 24,191 Bathroom 59 sq.ft. 479 18 497 1,689 Bathroom(2) 77 sq.ft. 568 18 586 2,038 Bedroom 323 sq.ft. 3,324 221 3,545 7,839 Bedroom(2) 168 sq.ft. 2,941 331 3,272 5,123 Bedroom(3) 110 sq.ft. 1,568 221 1,789 3,075 Bedroom(4) 156 sq.ft. 1,930 221 2,151 3,978 Hall 72 sq.ft. 162 0 162 263 Hall (2) 21 sq.ft. 47 0 47 77 Hall (3) 30 sq.ft. 68 0 68 109 Whole House 2,612.3 sq.ft. 27,582 3,184 30,766 82,257 (2.5 tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences. REINO E MYYPPA a ASSOCIATES Matthew Streeter CIVIL ENGINEERS III LAND SURVEYORS 108 Debbie Drive GLASTONBURY, CONN. SHED APPLICATION PLOT PLAN October 14,2021 10'x 16'Kloster Farm Shed with tie downs i �24G BAN DEBBIE ! �' DRIVE N 4 3u r)�)-- E i 1 O.OL' -- a I �, • ,110 \ W N 'i Ih :2 \ r Q IOU SIL 24.5' 11 ` m 10 ZF, jho.t, W N IP— WS N N U \ Z; « \ < ,, L1 \, � tun) t ul) O L 1 DECK r l O 6 Q �O G Io' I L 96 C 3"I'10+' G A 36' R — W Q G , ` 8 0 A -D y6'o'" r� Q , O S3-C 23'7 i1\.' O D 23 r9, W I 1 L 0 tv C�- � z s O 19 k +ledzs z 01 ! < zk AREA'20,0000 5.F -egq , • O ~ IOC).QO' •. snn 5 AV 30' 00- W, - - `1�� 1 272 sow t-nZym OPEN SPACE `C-t'TE: Scrx t,- 1Iv Nc�rN�,= 'I'e y \ \\ \2 90 1-14 P5 kA.(F t"Er- 3•Cr�q� SEE-_ Ruv (o x)-85 \ PREPARED FOR U3cwTEu An,`w+w.-.► CART HILL RSA LT Y I N h_ �titN�Vt�''v>TIONS Ct>iTIFIE� ;,,>FSTA•STIAL!V CnFiZECT SOUTH WINDSOR CONK. SCALE I"•40' ISCANNED[ re-f;5-i9 1o8��b� C7� IoXI4 C- i3LDP-ai--7qo REINO E HYYPPA 8 ASSOCIATES / CIVIL ENGINEERS IS LAND SURVEYORS GLASTONSiRY, CONq DEBBIE DRIVE N 4.0 3 c O'O E 4. 0 G ' Q u \ Q VOA T- M \ * ? 0 FIo�sE. o \ R Z6�• 1� N ` V W 1 3 44. \ Q `\ tab Lj \ Q- 0 O W �Q4 � \ 11 296 0 W 0 O 1t 1 O 3 Ir Ld ' 7 ` CL O a 19 - a ul A�?EA- 20,0000 S.F 3 0 sMM 5 4G" 30 C, w - - -- - OPEN SFACE �•, 3�o�w`- Ef-_ �t� . %' Ps �. PREPARED FOR CART HILL RE A LTY In' ClEgTIFIEL ���►".+TIAL�`! -> KCcT SOUTH WIN QR1 CONE'. 1 !8- 1~E- 19 f A P p P p E D TOV;N t,f,;......._ ENGINES r'r, , p '��t?SOR liiG ARTM&ENT sla., REINO E HYYPPA 6 ASSOCIATES CIVIL. ENGINEERS A LAND SURVEYORS GEASTONBiRY, CONk 21G DEBBIE ' DRIVE N_40 30 O'G E L 0 W f-- N Q' Q T �101 \ $O I.PG LIN p i4 zLi N \ 7 \ nn• N tt' - Q 00 9c W O \ 9 8O a a 3 \►I ,► N ° L4) W Z � Q O cr- Lo 2 A�EA= 20,0000 S.F 3 O O _ c sMM S 4G•` -50' 00- W, - - — :,,,�� l_�wF= �t�.• �,tt,t �!CITE 7"..�.:, � xl\' OPEN SPACE �_O7 �'.r•.f.+ �'E�'��J I N�'7.►NT:-.mot. �rJ S ' >-19 S6 W,A: -E:, 16 R►v P S PRE n-AREDFOR Eo Ar.,--*lmlw.J ,-24-t�(e CART HILL REALTY 1n ��I V U CEFTIF1EC ,:x)f_T.-'JT!ALLY MPRECI SOUTH WINCSO;, CON%. f - �CA�� I" •ace DATE co- I;E- 19 1- C I " .�� o Q Dq rE. NGI�ZFR�N REINO E. HYYPPA 6 ASSOCIATES / CIVIL ENGINEERS a LAND SURVEYDRS / GLASTONBJRY, CONr1 �29L 9" SAW DEBBIE _ T' DRIVE --- _ N 44� 30 O Y} E -�, w > T- _ _ 50'' LDG l I N 0 1aOUS� o R z� s• �� LLJ N Q 44 ' r \ Q- \ vim"' Ln O a ` o L_ . 0 29(. L) ) O 0 iYLi N C M N a_ } DoI O / ( a 19 Lo z� AR A'20,0000 S.F - , o o - ti ►oo.ob' sM„ S 11v 30 00- w, - - — -- 2 92 'Owl* `� � 5Doi t- 1-Yx OPEN SPACE =-D'A'E; �J'r Yv�M�'`.Ak,-0'J►J �e r ` �� 290 E : ,tea . f A.`_aCle•E: �:-. ,-&3 Z;t, 3-14 S5 4'-16 4.,fir- -5 crw`-EF Rry 6, -�0-95 \ PRE'.'ARED FOR �f��..l• L.oCATE�i a���w�, ,-Z4.�� CART HILL. REALTY IN�au ►ram Yr..a��o�� CEFTlFIE'C ':,F--!7PlJTIALLY CrWKECT SOUTH WINDSOR, CONN. �CA_E I' =40 DATE BE, c p re- pl- 19 REINO E. HYYPPA 8 ASSOCIATES CIVIL ENGINEERS S LAND SURVEYORS GLASTONBiRY, CONk 294 DEBE31E �' DRIVE IV 4lo° 3 O � O I �� O u0 W �`A LIN J� TF ZO14.`i LL) N Z� LP•'292..5 N � U 3 ` Q LJ \ Q �� b p 2 9 Lv Ct o r) W R O 1 n) o z Lai w I N Z 1 o c cr- L&I �g - z AREA= 20,0000 S.F - 99 3 o a Iv I-- ►oo.00 ` _ ChM 5 4(11' 30' 00" W, LOT LINE; CF^••MAC aJ FILE r, ♦ 'Oat,`_-,-c->r `-,W'vl s ow e-501�.r, OPEN S PA C E SATES -I<xr H vJ�W c5og,Zoww @ Y � tw. E. W-10P,#ASS�CIA'ES �►F 2 9n 7xA'O' Dc,-t1 J-14-85 LW too IF:%-P -16 N-EC' -5 o!<Iq!-"4EETS Rcv Io W-85 PREPARED FOR N -OWIWO Vk--ILATbN� DART HILL REALTY INC CERTIFIED `.�!FIA-JTIALLY CORRECT SOUTH WINDSOR, CONN. ` 5CALE. 1"•40' PATE l :8- F6- 19 so� OA7-C: REINO E. HYYPPA 8 ASSOCIATES CIVIL ENGINEERS a LAND SURVEYORS GLASTONBiRY, CONK rx � zoo DEBBIE ` DRIVE —_N�W ',:5 o� ' 010' E LA. O p �W v 3 ` \ I >. tits SO' LDG � Z� � to 5• '\ L� O W +'��''ue TF U Z 7rP•'12�'L�S ^I \ Q W 3 . a. z ILL) Li to Q O O0 29` W cx I ��.. u. 19 d AREA= 20,0000 S.F ` �e91 3 o 30' 00" W, _ 1.D'r Lvua c C-k VAC cio it k .E TTrL-E:_.\ y \ 292 •�-sue 5 4.'some-50ZLv-M OPEN SPACE C"m P-AN 5sc-no04 I EvJ �. f-5'ATf` 50-j H W,NL-rA,CDww "B, \290 ��µ�E }1••,yoq. �ASSxIe-E� oaf �s4:7� �D,Ti �-14 85 ►,/� lJO.iI~:1��-lb oF,q!-NE.ET's Rcv ro 3o as PREPARED FOR �I ZowIwJ, Yh-L,TofNS CART HILL REALTY INC CEKTIFIED SaeyzaNTIALL`1 CORRECT SOUTH WINDSOR, CONN. SCALE : 1••-40' QATE: s3� r8- IF;:- 19 s 'y^ -• _s,- 1700191 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 05/17/2017 GIS ID:26700108 FEE: 105.00 MUNIS APPLICATION# 201700533 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: FOREMOST MECHANICAL SERVICES LLC. ADDRESS: 108 DEBBIE DRIVE ADDRESS: 306 SCANTIC ROAD OWNER: STREETER MATTHEW&KARLA S EAST WINDSOR,CT 06088 108 DEBBIE DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: A/C REPLACEMENT. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 5/17/2017 3:42 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1700132 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 05/17/2017 GIS ID:26700108 FEE: 15.00 MUNIS APPLICATION# 201700533 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: TAYLOR ELECTRIC: ADDRESS: 108 DEBBIE DRIVE ADDRESS: 438 PLEASANT VALLEY ROAD OWNER: STREETER MATTHEW&KARLA S SOUTH WINDSOR,CT 06074 108 DEBBIE DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: WIRE NEW A/C OUTSIDE WITH DISCONNECT. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 5/17/2017 3:42 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE