Loading...
HomeMy WebLinkAbout106 EDGEWOOD DR IF 'Alt 15 2005 South Windsor BUILDING DEPARTMENT 10 Ift iai. l..rtr .. .._.., . This c&ftiti-d that this plan and rrreeilta•t1�n,-•,. copies of the proposed building or aitetations to a, erected at i OCQ together with ame ents stated in application fine tiled with plan and I agree to comply with all aoning, Building and state laws and such orders as shall b. / r issued by the Building Department during pendency •�f this application and final las nce of a building permit. n-e �. 4igne Xc rhis C plan is approved subject to the condition that ord.:rs and orotnances regulating building shall ba l uncd vIth. Conditionally Approved PAsae filed with Bulldtns Inspddtof; Clark )ate CE"F"TM OF Z( ^f^ftposw r-„ti APLIANCE 88 shown bWding���on th ructure(a) � conformance Wt rc be In...rvr Ngulations. Varian— May Windsor ma= apply. „ c""C' p;,c��:; exceptions Date l� !f:�!kg 14 1 iir ofrC_8ffq16--nT-tY\O�fflcewr1........ 2d El T Y L i no L o t 'o U2 on rat, entitic-l(I ki I dj v 0-1 i i ol ALEA.---r,%NT V,AL'-*X. 1.,sTF,, Conn. �,Cll c J 11 I 23 1 -,�3 c a e 5st.../-XNNED EN EDD APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT PP y r 3oa q50 APP 1540 SULLIVAN AVENUE 1n -1 OV 644-2511 ext. 230 Bldg.Permit# -f� Date Building Inspect Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 1 O '6 ci-7 AG-e u, Over$1,000= Street No. S eet Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 12 y L Lo 4-A D o, r`0Px, APPLICANT ADDRESS 1 0 (o g• W or' cT APPLICANT'S PHONE# a4 , 1 b 3 b OWNER S _ OWN SF •� q� OWNER ADDRESS OWNER PHONE g _ O ESTIMATED COST$ _ 11 S © O O Q C � U IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ D TYPE OF JOB: q 4 U SOR COS New Installation Alteration/Addition/Repair Revised 03/05/10 i APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑ HEATING U RESIDENTIAL ❑ A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 2 y �� Ca s T,rG ,Q iue nn rtf n I /i �� 1 Ll ce F4\V C(� aLr1 VO yy VL;n 00 �t'w.e.n< eKCh S�v1-per' w;�1 �aA. �►�SidP• ` GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH) 3 OOo B TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE& MODEL NO.) TONNAGE COOLING CAPACITY BTUH VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM CFM FRESH AIR INTAKE FM (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. Af/TG- 030373-1 -S/ l�Pg �r '� Y. lJ !"p :v�g CT CONTRACTORS LICENSE NO. TYPE Ca ,"n STATE SIGNAT OF APPLICANT DATE /D Empire 24 Inch cu Chan ed Oak Gas Log Set With Vent Free Nat... http://www.gaslogguys.com/item—item-2836004.htrnl 1 A (877)-743-2269 GASL0G GUYS.COM Mon-Fri 7-7,Sat¢3 CST r cOr:Sr,t e Live Chat I Store Locator Empire 24 Inch Super Charred Oak Gas Log Set With Vent Free Natural Gas Slope Glaze Burner-Variable Flame Remote Item#:2836004 1 View More From Empire $990.90 Quantity: t T M6RP $1,10100 1 Save:$110.10 FREE SHIPPING Ready to ship in 1-3 Business Days Customizations: Width 24 Inch CZ View Larger Image Fuel Type Natural Gas Log Series Charred Oak Check local codes for installation -- -- --- —- restrictions: Ignition Type Variable Flame Remote Currently,the state of California does not permit -—— - ---- ---_-_._._..-.-_---- --_—_-- -----..----.-.--..._the use of vent-free gas appliances. Safe&Secure Shopping Guaranteed Total Price: $990.90 Massachusetts requires board of State Examiners of Plumbers approval before installation.Local codes may vary,we recommend checking with local regulations if you have any questions. overview Specifications Shipping&Returns Learn More rrEMI#:2836004 MODEL#:LS24C2S+VFSV24N ■ Variable flame control lets you handle the atmosphere with the turn of a knob ■ Slope Glaze burners raise the standard for realistic dancing flames ■ ANSI Certified for safety ■ Super Size log sets include more logs for a fuller look in the fireplace ■ Flexible gas line required to complete installation(not included) Full Description Lugging logs in from the cold all winter,tending to a fire and cleaning out the fireplace are all things of the past with this Super Charred Oak log set!These exceptionally realistic logs are molded from Ceramic Fiber.Wood grain and bark detailing is then hand painted by the artisans at Empire.The matching vent free Slope Glaze burner provides 36,000 BTUs of supplemental heating power to quickly and efficiently heat your space.Ceramic beads inside the burner tumble the gas to create remarkably realistic flame movement.The Empire gas log Slope Glaze burner gives you a consistent flame that can be variably adjusted.The Slope Glaze burner is ignited by means of a push-button Piezo ignition switch. This vent free burner is easily converted to a vented burner simply by opening the fireplace damper.The super size log sets from Empire feature extra logs versus their regular counterparts for added presence in your fireplace.Number of extra logs varies by collection.For safety,an ODS (Oxygen Depletion System)will shut down the burner if the oxygen levels become unsafe.All gas log sets from Empire Comfort Systems are designed and tested to ANSI standards.Empire proudly manufactures their Gas Log sets in the USA! Customers Also Bought Customers Also Viewed Items From This Collection Items From This Brand 1 of 2 10/15/2013 5:08 PM Empire 24 Inch Supcharred Oak Gas Log Set With Vent Free Nat... http-://www.gaslogguys.com/item_item-2836004.htmi Peterson Real Fyre 24-Inch Peterson Real Fyre 20-Inch Peterson Real Fyre 24-Inch Empire 18 Inch Super Peterson Real Fyre 24-Inch Rugged Split... Ripped Split... Cedar Log Se... Sassafras Gas Log. Post Oak Log . Our Price: $495.55 Our Price: $759.05 Our Price: $1,080.35 Our Price: $1,015.20 Our Price: $334.05 User Reviews Item Reviewed:Empire 24 Inch Super Charred Oak Gas Log Set With Vent Free Natural Gas Slope Glaze Burner-Variable Flame Remote This item has not yet been reviewed. Write Your Own Review Recently Viewed Items Copyright©2013 Gas Log Guys com is owned and operated by ShoppersChoice.com® of 10/15/2013 5:08 PM DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Applicati TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT ��9•� APPRO 1540 SULLIVAN AVENUE Bldg. Permit# 644-2511 ext. 230 Date B ding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: -71 $0-$1,000=$15.00 F;T�e_nantDemsignation Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Apt.No. APPLICANT ::�;Cri�J l CtX . APPLICANT ADDRESS APPLICANT PHONE# cS K 6 3 O W N Se OWNER yGa S -4� OWNER ADDRESS l O i6 Q-Cy 6 4Q.� Ow l F, OWNER PHONE C = ESTIMATED COST$ a �.� IS THIS A CONTRACT COST? _Yes —No q FEE ENCLOSED$ rI`rOsO. CO�� TYPE OF JOB: R New Installation Alteration/Addition/Repair APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES D NO ❑RESIDENTIAL tf + ( L I t ❑BUSINESS CURRENT USE AND OCCUPANCY S 14 �_ b ❑ASSEMBLY U MERCANTILE FUTURE USE AND OCCUPANCY If - ® C'J ❑EDUCATIONAL ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE 0 GARAGE ADDRESS O MIXED USE S It�-- L) CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE < " 3 O &N,.JSIZE OF MAIN CONDUCTORS /4 e_ NUMBER OF METERS — NUMBER OF DISCONNECTS AND RATINGS _� NUMBER OF PANELS I REMOTE DISCONNECT REQUIRED? ❑YES 0 NO NUMBER OF LIGHT CIRCUITS 1 NUMBER OF POWER CIRCUITS ,3 NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. ff drt�� O C& r- A' CONTRACTORS LICENSE NO. TYPE STATE c SIGNATURE OF APPLICANT DATE N Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-31876-B 3,000 B10 FINAL 03/09/06 JFF D SHED COMPLETED NEED ELECT PERMIT CALLED OWNER TO APPLY AND CALL FOR INSPECTION B10 FINAL 03/17/06 JFF A WITH OWNER NOTE ELECT PERMIT ON FILE APPLICATION FOR BUILDING PERMIT Electric # _ Plumbing# 106 Edgewood Drive Date: 7S 61 —� HVAC # Sprinkler# - - --- -31$7� -- -- - 0 FINAL R F0000" SIGN _ __.___ - Estimated Cost Buildings�7 oe Permit Fee $_ � En nee n PLETE RED BOXED AREAS 1 Occupancy Fee $ /0, YPE OR PRINT ONLY Eng. Insp. Fee $ �6 ON REVERSE SIDE Affidavi Appr. for COjj Total Fee TO THE BUIL ING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant.A 0eco C-A w e.-un i `6ocation of Work I oG I OA • .S.LA)Lot No. Applicant's Address el f 0 et 'del.# Mr. Town d Zip _Lic.# c� 0tOwner7 { _Architect Owner's Address / b�F ty f!"c d&_Architect's Address _ Zip Zip- -Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area --Purpose of this permit trr-C>C J .S?�o �E' -��I Pc ` X c( City Water❑ Well❑ Septic System❑ Sewer❑ Ins: HO V, Sp Cert. Area Basement Garage Approved by Date Use Group Construction Type 5�3— Revised 6102 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in whi this building and its use is allowed. \ Sig d �' r.zei I hereby apply for a Certificate of Occupancy for the work described inthis application for the permit. Signed f'aU DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR s HOMESAVEK ULTRAPROm FLEXIBLE STAINLESS STEEL RELINING PIPE C UL US LISTED lifetime Warranty UL/ULC Listed Sizes:3"-8"diameters Manufactured Exclusively for:Copperfield Chimney Supply, 304 South 20th Street, Fairfield,IA 52556 INTRODUCTION HomeSaver'UltraProT"" flexible stainless steel relining pipe is intended for use in conjunction with residential heating appliances which burn wood,wood pellets, coal,oil,any Category I LP or natural gas appliances,and gas logs installed in a fire- 1 place. HomeSaver UltraPro can be installed in masonry or certain factory-built chimneys. HomeSaver UltraPro relining pipe is a high-quality, patented, flexible, stainless steel lining system.It has been tested and listed by Underwriters Laboratories,file #MH13768. HomeSaver UltraPro is made of high-quality, 316 Ti-alloy stainless steel.This maintains the corrosion resistance while also giving the benefits of high heat resistance. HomeSaver's commitment to provid- ing a product of superior quality is reflected in its obtaining the UL Listing. The testing is very stringent, and UL ensures consistency of the product by regularly inspecting the manufacturing facility and materials. This commitment is also reflected in HomeSaver's excellent warranty. This liner is also ULC listed to ULC- S635-00 for use in existing construc- Figure I tion. HomeSaver UltraPro is a corrugated liner with a unique mechanical, roll lock seam.These seams are gas tight and hold tight no matter how much you bend or shape them(Figure 1). HomeSaver requires that an experienced professional who works with chimneys on a regular basis perform the installation of HomeSaver UltraPro relining pipe. HomeSaver UltraPro is tested and listed to the UL 1777 Standard which requires insulation for wood and coal appliances. Use only the parts described in these installation instructions. These installation instructions must also be followed to ensure the prevention of moisture from entering the liner,the space between the liner and factory-built or masonry chimney,and the chimney insulation. 2 DETERMINE RELINE NEED/CODES AND SAFETY SECTION 1 How To Determine If A Reline Is Needed A reline is advisable when: ■ The chimney has missing or damaged flue tiles or mortar is missing between flue tiles. ■ A chimney venting solid fuels is exposed on at least one side to the outside below the roofline and the flue area exceeds two times the area of the appli- ance flue collar. ■ A chimney venting solid fuels with no sides exposed to the outdoors below the roofline has a flue area exceeding three times the area of the flue collar. ■ Deemed necessary by the appliance manufacturer. ■ Deemed necessary according to the NFPA 31 Oil Standard or the NFPA 54 Fuel Gas Code Book or your local codes or authority bearing juris- diction. ■ The system has a history of repeated excessive creosote and/or mois- ture buildup. SECTION 2 Important Code And Safety Considerations CHIMNEY HEIGHT Height above The National Fire Protec- any roof tion Association Standard within 10 feet 211 requires that the chim- Ridge ney extend at least 3'above 2'min. i the highest point where it Chimney 3'min. f passes through the roof and at least 2' higher than any structure within 10' (Figure 2). Figure 2 3 CODES AND SAFETY CLEARANCES Airspace clearances between the chimney exterior and combustible materials should be checked to verify whether the chimney is in accordance with the clear- ance specifications contained in: 1. NFPA 211 2. Other recognized major building codes 3. These instructions 4. Factory-built chimney manufacturer's instructions t NFPA 211 states that the minimum airspace clearance between exterior masonry chimneys (which have the chimney completely outside the exterior wall of the building,excluding the soffit or cornice area)and combustible material shall be at least 1" NFPA 211 states that the minimum airspace clearance between interior masonry chimneys(which have any portion of the chimney located within the exterior wall of the building) and combustible materials shall be at least 2" The airspace shall not be filled. Factory-built Chimneys Before beginning the installation,determine if the existing factory-built fireplace and chimney system has been installed correctly and required clearances have been maintained. Be sure the factory-built chimney and components are not warped, rusted,or damaged in any way.The system must be structurally sound.If there is damage to the system,insufficient clearances,or rusting of components,this must be remedied!Do not install a liner if the above requirements cannot be met! Make sure you are connecting to an appliance that has been listed for installation in a zero clearance fireplace and that all clearances and requirements set forth by the listed insert manufacturer have been met.Also make sure the fireplace manu- facturer has approved this type of installation.This installation is approved for these types of appliances with a 6,4",or 3"collar only.Only a 6,4",or 3"HomeSaver Pro, HomeSaver UltraPro,or HomeSaver RoundFlex liner may be used. 1 Installations in factory-built chimneys do not meet UL requirements and are not list- ed for this application. CONNECTING OTHER APPLIANCES Use of this liner is approved for wood,wood pellets,coal,oil,any Category I LP or natural gas appliances,and gas logs installed in a fireplace.However,remember:You 4 MATERIALS TO USE cannot connect gas or oil appliances to a liner serving solid fuel-burning appliances. You cannot connect more than one,solid fuel-burning appliance to a single liner. Rain Caps Listed rain caps with bird screens are necessary and/or required in some areas but may be susceptible to blockage through freezing moisture in areas of low ambient temperature.Consult authority having jurisdiction for any special requirements. s SECTION 3 Determining The Materials You Need 1.WHAT SIZE OF HOMESAVER ULTRAPRO LINER TO USE For solid fuels,the cross-sectional area shall not be less than the area of the appli- ance flue collar unless specified in the manufacturer's instructions. Please refer to the chart in Figure 3,which gives the cross-sectional areas for 3"—8"HomeSaver U1traPro. When using HomeSaver U1traPro to vent a fireplace (Figure 4), if the chimney is straight and you are using a round pipe,the cross-sectional opening of the flue liner (Area A) should be no less than 1/12 of the face opening of the fire- place chamber (Area B) to ensure proper draft. If the chimney is offset,or if the liner is square,oval or rectangular,the flue liner shall not be less than Vio of the fire- place opening.You should refer to the current NFPA 211 for additional sizing spec- ifications. For oil-burning appliance venting,the flue shall be sized according to the NFPA 31 Oil Standard or the appliance manufacturer's instructions. For LP or natural gas Area A CROSS-SECTIONAL AREA FOR EACH SIZE OF PIPE: 3"Round ..........7.06 sq.in. 4"Round ..........12.56 sq.in. 5"Round 19.60 sq.in. 5.5"Round 23.80 sq.in. 6"Round 28.30 sq.in. 7"Round 38.50 sq.in. 8"Round 50.30 sq.in. Area B Figure 3 Figure 4 5 MATERIALS TO USE appliance venting,the flue shall be sized according to the NFPA 54 Fuel Gas Code Book or the appliance manufacturer's instructions.It is especially important for the liners to be properly sized when venting appliances with low flue gas temperatures in sustained low ambient temperatures. In all cases,the authority having jurisdic- tion can mandate sizing. 2.DETERMINING WHAT LENGTH OF HOMESAVER ULTRAPRO LINER IS NEEDED Determine the length of liner needed by lowering a weighted rope down the chim- ney to where your relining pipe will terminate.Add another 3"for the installation of the top clamp, storm collar, and Guardian" Cap or the CollarPlate and CollarPlate Rain Cap. If needed,HomeSaver U1traPro may be cut with an angle grinder or circular saw with a metal-cutting blade. The maximum recommended height for HomeSaver U1traPro is 65' Minimum height is 10' 3.INSULATING THE LINER Insulation is required when venting solid fuel appliances but is optional for wood pellet appliances,oil appliances,and Category 1 LP or natural gas-burning appliances. Wood And Coal Applications There are three scenarios you may encounter when lining for wood and coal that will affect your choice of insulation options. In a case where a masonry chimney is found to have at least 1"clearance to com- bustibles the minimum insulation requirements are one wrap of 1/4"foil-face insu- lation or 1"of HomeSaver InsulationMix or TherMix insulation. When less than 1" clearance exists between the exterior of the masonry and the surrounding combustibles,the minimum insulation requirements are one wrap of 1/2" foil-face insulation, two wraps of 1/4' foil-face insulation, or 1" of HomeSaver InsulationMix or TherMix insulation. The insulation requirement for a properly installed factory-built chimney is one wrap of 1/2'foil-face insulation. Remember: the insulation wraps will loft to more than their stated thickness in most cases.One wrap of 1/4"insulation will add 1"to the diameter of the liner.Two wraps of 1/4"will add 2"to the liner diameter.One wrap of 1/2'will add 11/2"to the 6 MATERIALS TO USE liner diameter. Go to pages 16 and 17 for the formula to determine how much HomeSaver InsulationMix or TherMix will be needed in a particular installation. i HomeSaver offers insulation kits including all the components needed to insulate a liner with the foil-face insulation trimmed to the appropriate widths.These are available in 25'lengths of 5"—8"diameters.There are two additional insulation kits for 6"liners in 30'and 35'lengths. a Wood Pellet,Oil,And LP Or Natural Gas-Burning Appliances Since the use of insulation around HomeSaver U1traPro keeps the liner warmer, one wrap of 1/4"Foil-Face FlexWrap will help reduce condensation,as well as reduc- ing cold spots which affect chimney performance. This is especially important when the flue gas temperature is below 280OF at the thimble,when large portions of the chimney are located on the exterior of the house,when HomeSaver UltraPro is venting a fan-assisted Category I gas appliance,or when the flue cavity is much larger than the liner. Using HomeSaver Foil-Face FlexWrap HomeSaver Foil-Face FlexWrap is an insulating blanket of special ceramic fibers mated to a heavy reflective foil.The use of FlexWrap around HomeSaver U1traPro relining pipe will help center the liner in the chimney,in addition to the other ben- efits previously mentioned. To determine the width of FlexWrap needed,see Trim Chart,(Figure 5,next page). Adhesive and foil tape will be needed to adhere the FlexWrap to the liner. FlexWrap must be covered with ArmorMesh to protect the FlexWrap from tearing during installation—see the chart,(Figure 6,next page),to determine what size is needed.Clamps for fastening the ArmorMesh at the top and bottom will be need- ed and can be created from a Make-A-Clamp brand clamping kit,or large radiator- type clamps which can be purchased at automotive supply stores. 4.COMPONENTS s U1traPro installations on a masonry chimney can be finished with two different top plate options.It's important that these instructions are followed to ensure the pre- vention of moisture entering the liner,the space between the liner and factory built chimney and the chimney insulation.The first utilizes the HomeSaver CollarPlate which incorporates all the features of the top plate,top clamp,and storm collar into one unit and the HomeSaver CollarPlate Rain Cap with band connection or a 7 Y MATERIALS TO USE TRIM CHART- 1 HOMESAVER0 FLEXWRAV INSULATION 11) HomeSaver' Cut this width Cut this width Cut this width UltraPro-sizefor first for second(outer) for to be used 1/4"wrap 1/4"wrap 1/2"wrap 3"dia.......... 123/4" 14" 131/2" 4"dia.......... 16" 171h" 17" 5"dia.......... 191h" 21" 191/2" 5.5"dia. 211/2" 231/2" 211/2" 6"dia.......... 23" 25" 221/2" E 7'dia.......... 271/2" 291h" 261/4" 8"dia.......... 30" 32" 291/4" Figure 5 Guardian cap.The second involves a top plate,top clamp(or top/bot- WHICH SIZE A DIFFERENT SIZESSH- O USE WITH tom support brackets), storm col- DIFFERENT SIZES OF PP HOMESAVER'ULTRAPRO" lar, and one of the UL Listed cap Use this size types. The cap options are a HomeSaver® ArmorMesh"with Guardian cap,inverted cone cap,a UltraPresize all insulation Gelco knock-down top, or a to be used combinations Chimney Protector. 3"-6"dia. Small When installing UltraPro in a fac- 7"-8"dia. Large tory-built chimney, the top must Figure 6 be finished with the Factory-Built Liner Adaptor, top clamp, storm collar, and Guardian Connector- cap. Adaptor With Band Connection To connect two pieces of U1traPro a connector adaptor with band connection is used. This allows a drip free connection,Figure 7. Bottom terminations will vary with the specifics of each installation.These specifics are discussed at length later Figure 7 in these instructions. Important Note:Do not use any liner parts except those specified in these installa- tion and maintenance instructions. SECTION 4 Before You Begin The following tools and supplies are basic ones needed for your HomeSaver U1traPro installation: 8 TOOLS AND SUPPLIES Trowel Mortar Mortar pan Steel snips Silicone sealant File Ladder Pop rivet gun Utility knife Electric drill 316-alloy S.S.pop rivets Measuring tape 9/64"high-speed drill bit Hammer Screwdriver Cold chisel Gloves Pliers Eye protection Rope Caulking gun 3/16"masonry drill bit Safety Harness ,i Circular saw with metal-cutting blade(or similar tool) Respirator(MSA Comfo Classic or equivalent) Wear eye protection,gloves,and respirator whenever you're in contact with cre- osote,soot,mortar,or insulation.Use caution when working on a roof.Proper and safe scaffolding should be used for a safe installation.All ladders should be secured to the building.Be sure to check overhead for antennas,power lines,or other obstacles before erecting the ladder and installing the liner. INSPECT THE CHIMNEY Inspect the chimney for structural integrity before it is lined.HomeSaver UltraPro relining pipe can be installed in a masonry chimney with a minimum 4"of solid brick as specified in NFPA 211. Look for loose or eroded mortar, cracks in the masonry,missing bricks, internal obstructions,abandoned flue holes,and exces- sive creosote accumulation.Make necessary masonry repairs prior to relining.. In the case of a factory-built chimney,determine if the chimney and factory-built fireplace have been-installed correctly and required clearances have been main- tained.Check to make sure no signs of rust,warpage,or other damage exist.The system must be structurally sound. If there is damage to the system, insufficient clearances,or rusting components,these parts must be replaced or installed prop- erly.Do not install a liner if the above conditions dor t exist. Installations in factory-built chimneys do not meet UL requirements.and are not list- ed for this application. CLEAN THE CHIMNEY Clean and remove all tar-glazed creosote and soot found on internal chimney walls and the fireplace smoke chamber before relining the chimney.If not removed,cre- osote is a fire hazard.It can also cause an unpleasant odor. TEST TO MAKE SURE THE LINER FITS On any installation where minimum or near minimum inside chimney dimen- 9 INSTALLATION sions are present, always test your fit before proceeding. Chimneys are irregular and hard to"sight"accurately.Take a small scrap section of liner,about 2'in length, then wrap it with the required thickness of F1exWrap (if this is your insulation choice).Be sure this"test section"can be lowered easily,without binding,through the entire length of chimney. � SECTION 5 Doing The Installation The following instructions are intended as a guide to assist a qualified profession- al installer.Check your local building codes and contact local building or fire offi- cials to obtain any required permits. 1. Inspect the chimney for structural integrity before it is lined. HomeSaver UltraPro relining pipe can be installed in a masonry chimney with a minimum 4"of solid brick as specified in NFPA 211. Look for loose or eroded mortar, cracks in the masonry,missing bricks,internal obstructions,abandoned flue holes,and excessive creosote accumulation.Make necessary masonry repairs prior to relining the chimney. In the case of a factory-built chimney,determine if the chimney and factory- built fireplace have been installed correctly and required clearances have been maintained. Check to make sure no signs of rust,warpage, or other damage exist.The system must be structurally sound.If there is damage to the system, insufficient clearances, or rusting components this situation must be reme- died.Do not install a liner if the above conditions dolt exist. 2. If you are relining a fireplace,go to point 7,page 13. If the liner is to be connected to an insert,determine if the liner will line up with the flue collar on the insert top. If it does,and the collar is round,use a HomeSaver connector/adaptor to make the connection.The connector/adap- tor should be securely attached to the liner. The male end of the adaptor should then fit into the insert flue collar and stainless screws may be used to attach it to the collar Figure 8. If the liner angles towards the insert collar,or has an oval or rectangular open- ing,a HomeSaver RoundFlex cast-iron insert boot or an elbow may be used to connect the liner to the insert.If an insert boot is used,an insert boot adaptor is needed to connect the UltraPro to the insert boot. 3. If you are relining a flue venting a woodstove and there is no existing opening 10 INSTALLATION for stovepipe,you now need to make i I one. If there is an opening, it may need to be expanded in order to assemble the take-off to the flex tee. For solid fuel appliances the NFPA "minimum clearance to com- bustibles" is 18" for single-wall con- nectors. Figure 9, page 11, shows a typical framing,which would have to be constructed in a combustible wall next to the chimney. This framing requires a minimum of HomeSoverUltroPro 12" of brick masonry Wrapped With surrounding the thim- HomeSover Foil-Face ble on all sides. It must FlexWrap Protected With not be located directly HomeSoverArmorMesh behind the appliance, Connector HomeSaver UltraPro Installation Adaptor,Secures Liner Using Cast-iron Insert Boot To Insert Collar HomeSaver U1troPro Fireplace Cast-Iron Insert Insert Boot RoundFlex Cast-Iron Insert Boot Figure 8 but above it. See NFPA 211 for more details. If a UL Listed wall penetra- tion assembly is used (as an alternative to Figure 9), it must be located above the Minimum heating appliance and may clearance to combustibles not be located directly behind per NFPA 211 the heating appliance. Fig.9.7.5 Clearances from solid fuel- Figure 9 11 INSTALLATION burning appliances to combustible materials must be strictly adhered to. Follow all local codes and manufacturer's instructions. For Category I LP or natural gas you may make a 90 degree bend when pass- ing through a masonry thimble.You will need to use a mortar sleeve in this application. If this liner is installed in Canada,a notice must be posted where the connec- tion is made to the appliance concerning its limitation of use with specific fuels and appliances including a reminder to homeowners to check the rain cap for icing during low ambient temperatures.Such notices shall include the date of installation,the manufacturer's name,the model number,and class of lining system. I 4. To install the tee, first place the tee cover over the outside of the bottom end using four,1/2"316-alloy stainless pop rivets to secure(Figure 10). In hearth stove applications, 1/2"#8 stainless steel screws may be used to con- nect the tee cover to the tee. The take-off attaches to the tee body with a retractable band connection. The first tee,left,Figure 10,is called the Flex Tee With Removable,Uncrimped Take-Off With Band Connection.The UltraPro slides into the top of the tee and is secured by tightening the Short Flex Tee With retractable band Flex Tee With Removable, 10"Long,Removable, Uncrimped Take-Off With Uncrimped Take-Off connection. There Band Connection With Band Connection are also four pilot Band connection Band connection Tee body holes where 1/2" Retractable Retractable 316-alloy pop riv- Tee body band band ets may also be used if desired. Tee take-off The take-off Rivet 10'long tee attaches to the tee Tee cover Tee cover Rivet take-off body with a Figure 10 retractable band , connection. The second tee,on right,Figure 10,is called the Short Flex Tee With 10"Long, Removable,Uncrimped Take-Off With Band Connection.The UltraPro slides into the top of the tee and is secured by tightening the retractable band con- nection.There are also four pilot holes where 1/2"316-alloy pop rivets may also be used if desired. 12 INSTALLATION These two tees have a retractable band that secures the take-off to the tee body. The band should be opened so that when the HomeSaver Flex and tee are low- ered down the chimney,the tee can pass through the band. If a crimped take-off or a longer take-off is desired,a 6"or 8"diameter crimped take-off and a 6"diameter 22"long take-off are available as an alternative to the standard tee take-off.These alternative take-offs are designed to be used solely as a replacement tee take-off. 5. Install support rods and bottom plate as shown (Figure 11)so the take-off will line up with the thimble hole.The tee sits on the plate which supports the weight of the liner. 6. Attach the UltraPro liner to the tee with the clamp connection.As an alterna- tive,a connector-adaptor with band connection may be used to join the liner to a Heat-Fab rigid tee. 7. When using HomeSaver UltraPro Stainless steel relining pipe to reline a fireplace bottom plate flue, terminate the liner at the bot- tom of the chimney flue just above the smoke chamber. Termination is Support rods (1/2 inch minimum illustrated page 15, Figure 12.As an thickness or alternative method of support, a diameter) HomeSaver Bottom Plate Leg Support System can be used instead of support rods(see Figure 12,page 15, alternative "A.") Install the four support brackets by bolting to the Figure 11 liner in a position that allows them to rest on the bottom plate,and so no more than 2"of liner is below the plate. Or, a bottom plate with 2" collar may be used. A connector-adaptor will be needed to join the liner to the collar. Another choice is the Home-Saver Insulation Plug(see Figure 12,alternative "B,"page 15).HomeSaver Foil-Face FlexWrap must be layered with refractory cement and tightly packed at the base of the liner to a depth of 6" to form a seal.Make sure there is adequate support at the top of the chimney.If the liner, including insulation, weighs more than 150 pounds, double up on the top plates and top/bottom support brackets. 8. Each of these liner components(tee and connector-adaptor)comes equipped with band connection.The tee cover requires pop rivets or screws. Note:If you are using a connector/adaptor with band connection or a tee with 13 INSTALLATION band connection,pop rivets are optional. 9. Insulating the liner with HomeSaver Foil-Face FlexWrap: A. Wrap lengthwise,creating one long vertical seam down the length of the , liner.The foil side should face away from the pipe. B. Begin by rolling out a length of FlexWrap equal to 9"less than the length of the liner to be used in the installation.Do this on a clean,dry surface. If relining a woodstove insert installed in a masonry fireplace, I'to 2'may be left uninsulated immediately above the insert.(For factory-built chim- neys,see page 19.) C. Trim the FlexWrap lengthwise with a sharp utility knife so that when wrapped around the liner,a tight joint,the length of the liner,is achieved. Accuracy in cutting is important. D. Apply 3M Spray Adhesive or Rutland Water Glass to the liner.Then care- fully wrap the FlexWrap around the liner. E. Thoroughly tape the insulation seam and the ends with foil tape. F. If two wraps of the'/4" Foil-Face FlexWrap insulation is required,repeat the steps above for the second wrap. G. Measure,cut,and install a length of HomeSaver ArmorMesh Insulation Cover over your FlexWrap insulation. This can be accomplished by rolling the mesh like a stocking, then unrolling over the insulated pipe. Clamp the bottom end of the ArmorMesh,just before it enters the tee. H. Grasp the undamped end of the ArmorMesh, unroll the ArmorMesh over the liner and insulation and pull,working it tight from one end to the other.This will draw the ArmorMesh snug around the FlexWrap. I. Trim any excess FlexWrap and ArmorMesh from the top of your installa- tion back to within 6"of where the liner will stick through the top plate, collarplate,or factory-built liner adaptor,then clamp it in place.Leave no more than 3" of liner protruding above the flex top plate. If using a CollarPlate,cut the liner flush with the top of the collar. 10. Insulating UltraPro with HomeSaver InsulationMix or TherMix Insulation: HomeSaver InsulationMix and TherMix are specially formulated, dirt-like consistency chimney fill insulations and are intended for use when relining masonry chimneys only. Since 1" of HomeSaver InsulationMix or TherMix needs to surround the liner on all sides,the inside flue dimension needs to be a minimum of 2"larger than the outer diameter of the liner(which is 3/8"larg- 14 • nrl► _ 1! s \� �/ I► MR. ' pr Y �1• INSTALLATION er than I.D.).This means a 6"diameter liner would require a flue opening of 8j/,;"X 83A" The formula for determining the volume of insulation in cubic feet for HomeSaver U1traPro is: (area of chimney) (area of liner) (W" X D" X H")-(n X R2 X H") 1728 W=width of flue in inches D=depth of flue in inches H=height of flue in inches(multiply feet X 12 to convert to inches) 1r=3.1416 W=radius of pipe multiplied by radius of pipe(remember,radius is'h diameter) Dividing by 1728 converts the answer (in inches) to the number of cubic feet of space you need to fill with HomeSaver InsulationMix or TherMix. Each bag of HomeSaver InsulationMix holds two and a half cubic feet,so divide the final fig- ure by 2.5.TherMix holds 2.4 cubic feet,so divide the final figure by 2.4 to deter- mine the number of bags of TherMix you need. The following are typical examples: A. 6"=diameter of HomeSaver U1traPro relining pipe 81h"=width of flue 81/2"=depth of flue (16 ft.) 192"=height of flue (8.5 X 8.5 X 192)—(3.1416 X 9 X 192) 8443.32 = 4.89 cu.ft. 1728 1728 4.89 cubic feet_2.5 cubic feet/bag= 1.96 bags(InsulationMix) 4.89 cubic feet 2.4 cubic feet/bag=2.04 bags(TherMix) B. 8"=diameter of HomeSaver U1traPro relining pipe 101h"=width of flue 12"=depth of flue (35 ft.)420"=height of flue (10.5 X 12 X 420)—(3.1416 X 16 X 420) _ 31,808.45 18.41 cu.ft. 1728 1728 18.41 cubic feet_2.5 cubic feet/bag=7.37 bags(InsulationMix) 18.41 cubic feet 2.4 cubic feet/bag=7.67 bags(TherMix) Be sure to follow the instructions on the bag for mixing,drying, and curing requirements. 16 INSTALLATION 11. In installations using a tee,position the tee take-off with retractable band into the chimney opening. The retractable band should be fully opened so the body of the HomeSaver tee may be lowered through the band.Then the band must be secured to the tee body by tightening the retractable band. The HomeSaver universal takeoffis used generally to connect a water heater or other gas appliance into HomeSaver U1traPro above another connector.Drill a hole in the liner using a hole saw. Place duct tape over the area and drill in reverse for improved results.Insert the universal takeoff into the hole,tighten the band,and seal with RTV silicone sealant. Fill mortar in tightly around the take-off to the tee.Make sure the connector pipe will connect easily to the take-off before the mortar cures. Single-wall metal connectors must maintain a minimum of 18"clearance to combustibles and a rise of at least 1/4"per foot.Connectors shall be securely supported and fastened with sheet metal screws or stovepipe screws.The connector shall be readily accessible for inspection,cleaning,and replacement. The initial pipe connection will either be a direct connection to the take-off of the flex tee in a HomeSaver U1traPro installation,or a connector through a UL Listed wall penetration assembly. Any pipe connector used, which is not in plain view from the room,must be made of stainless steel or equivalent mate- rials. When relining to a wood or gas insert, a connector-adaptor with band con- nection will be needed to make the connection to the insert.As an alternative, a RoundFlex cast-iron insert boot and insert boot adaptor may be used. In fireplace installations,lower the liner directly down the chimney until the top/bottom support brackets rest on the stainless bottom plate(if one is used). If installing UltraPro in a factory-built fireplace chimney, make sure you are connecting to an appliance that has been listed for installation in a zero clear- ance fireplace and that all clearances and requirements set forth by the listed insert or stove manufacturer have been met. Also make sure the fireplace manufacturer has approved this type of installation. This installation is approved for these types of appliances with a 6",4;or 3"collar only.Only a 6",4,or 3"HomeSaver Pro or HomeSaver UltraPro liner may be used. If a hearth stove will be connected to the liner,determine which type of tee will be used(see page 12 for specific recommended tees). If an insert will be connected to the liner,you may use a HomeSaver connec- 17 INSTALLATION K�I HomeSaver Guardian Cap r HomeSaver Top Clamp HomeSaver Storm Collar uFET►ME HomeSaver Factory-Built Liner vypRRAP17►ED Adaptor(patent pending),item#14940 HomeSaver 6"Chimney Liner (RoundFlex,Pro,or UltraPro).W'Foil- Face FlexWrap insulation and insu- lating components required,but not shown. Double-wall factory-built chimney (minimum 8"inside diameter) I s,' 1 1 I HomeSaver Insert Adaptor HomeSaver Insert Boot(not needed for most installations) Figure 13 18 INSTALLATION for/adaptor with band connection to make the connection between the flex and the insert if it has a 6',4",or 3" inside dimension flue collar. If the liner comes down towards the insert at an angle,or has a rectangle or oval flue col- lar equal to or less than 28 square inches of area,you may need two items. They are the HomeSaver RoundFlex cast-iron insert boot, as well as the HomeSaver Pro/UltraPro cast-iron insert boot adaptor,Figure 8,page 11. Remove the damper from the top of the firebox following the specific instruc- tion as required from the zero clearance fireplace manufacturer.Be careful not to affect the structural integrity of the unit. Insulate the liner with one wrap of t/z"HomeSaver Foil-Face F1exWrap includ- ing the adhesive,the ArmorMesh,foil tape,and Make-A-Clamp kit as detailed on page 7.Or,a 6'HomeSaver Pro/UltraPro Insulation Kit may be used which includes these items. The insulation must start 6"above the appliance connection and must termi- nate 6"below the factory-built liner adaptor. There are three accepted methods of installing the top hardware on an UltraPro installation. Using the CollarPlate:apply an exterior-rated silicone sealant to the perimeter of the CollarPlate. Slide the plate over the liner until it rests squarely on the chimney or flue tile. Tighten the clamp. Install the CollarPlate rain cap or a Guardian cap. If you are relining a factory-built chimney, use the HomeSaver Factory-Built Liner Adaptor, Figure 14. Allow the liner to extend 3" spoke Guardian cap above the adaptor. Install the storm collar over the liner, making sure the bot- m Top clamp tom of the storm collar sits _--Storm collar flush on the liner adaptor. Factory-Buih Seal with high tempera- P0 Liner Adaptor of ture silicone sealant. Outu factoory--bb r uilltl Install the top clamp above chimney the storm collar so it sits on Inner wall of factory-built the collar.Squeeze the base - % chimney of a Guardian cap and slide \HomeSaver I\chimney liner it into the liner.See illustra- 11 Insulation tion. Figure 14 19 INSTALLATION When using a 4"or 3"liner,use the pellet adaptor. If you are using a top plate, apply an exterior-rated silicone sealant to the perimeter of the top plate. Slide the top plate over the liner until it rests squarely on the chimney top. Next, Chimney Top or position the top clamp or top/bot- Chimney Protector tom support brackets over the liner Top Clamp so it rests on the top plate, then Top Plate secure to the liner. Do not allow the top clamp or top/bottom support brackets to be Figure 15 the installation's sole means of sup- port.Always support your installation solidly at the bottom.Position the storm collar so it is above the top clamp and tighten the storm collar.A bead of sili- cone sealant between the collar and the pipe will prevent water from entering the chimney through this joint.Insert the friction fit 316-alloy Guardian Cap into the liner. A Gelco Knock-Down Top, inverted cone cap, or Chimney Protector Cap may be used as an alternative to terminate a HomeSaver Relining Installation, (Figure 15). A storm collar is not required but may be used with a Chimney Protector or Gelco Chimney Top.Allow a maximum 3" of HomeSaver Liner to extend past the top plate. Make sure the combined height of liner and tile extend into the cap no more than 4"for the Chimney Protector with 10"high mesh and no more than 6" for the knock-down tops and Chimney Protectors with 12"high mesh.This ensures adequate clearance for the liner. To install the cap you will need a caulking gun,drill,and a 3/16"masonry drill bit.Set the cap on the crown of the chimney,marking with a pencil where the base will sit.Apply chimney top adhesive within the penciled lines. Be sure to leave spaces where the holes for the masonry screws will be drilled. Firmly press the cap base into the adhesive.Drill into the crown using the 3/16"drill bit and anchor the cap with masonry screws. 13. After completing the installation of a new appliance,the initial firing precau- tions of the appliance manufacturer's instructions must be strictly fol- lowed. 20 INSTALLATION SECTION 6-PLEASE READ AND SAVE Maintenance Instructions For Installer And Homeowner HomeSaver's commitment to providing a product of superior quality is reflected in its excellent warranty and UL/ULC Listing. HomeSaver UltraPro relining pipe must be installed and used correctly in order to have the safest,most efficient,long- lasting system. For this reason,the following maintenance and usage instructions must be followed.Parts or materials other than those specified in our installation instructions must not be used. MAINTENANCE 1. The chimney connector pipe and HomeSaver U1traPro system must be cleaned and the entire installation inspected annually by a professional chim- ney sweep. During the heating season, the chimney liner system should be Maximum Liner Size Per Cap With Without Screen Model Storm Storm Size Number Description Collar Collar 9"x13" 11705 Chimney Protector with 10"mesh 4" 8" 13"x20" 11710 Chimney Protector with 10"mesh 6" 12" 13"x24" 11714 Chimney Protector with 10"mesh 6" 12" 13"x26" 11716 Chimney Protector with 10"mesh 6" 12" 13"x28" 11718 Chimney Protector with 10"mesh 6" 12" 13"x36' 11726 Chimney Protector with 10"mesh 6" 12" 14"x14" 11730 Chimney Protector with 10"mesh 9" 12" 14"x 14" 13212 Knock-Down Model A Cap with 12"mesh 9" 12" 17"x17" 11740 Chimney Protector with 10"mesh 10" 12" 17"x 17" 13222 Knock-Down Model B Cap with 12"mesh 10" 12" 17"x22" 11742 Chimney Protector with 10"mesh 10" 12" 17"x29" 11746 Chimney Protector with 10"mesh 10" 12" 17"x29" 13231 Chimney Protector with 12"mesh 10" 12" 17"x29" 13234 Knock-Down Model C Cap with 12"mesh 10" 12" 17"X35" 11750 Chimney Protector with 10"mesh 10" 12" 17"x41" 11754 Chimney Protector with 10"mesh 10" 12" 17"x41" 13248 Chimney Protector with 12"mesh 10" 12" 17"x41" 13244 Knock-Down Model D Cap with 12"mesh 10" 12" 17"x49" 11760 Chimney Protector with 12"mesh 10" 12" 17"x58" 11758 Chimney Protector with 10"mesh 10" 12" 17"x58" 13254 Knock-Down Model E Cap with 12"mesh 10" 12" 21 MAINTENANCE inspected at least once every two months to determine if creosote or soot buildup has occurred.If buildup has occurred,it should be removed to reduce the risk of a chimney fire. 2. A round wire steel chimney cleaning brush is recommended to clean HomeSaver U1traPro liner.Some chemical chimney cleaners may be harmful to HomeSaver UltraPro,so use only brands approved by HomeSaver. The chimney may be accessed for cleaning through the top by removing the rain cap. If unaccessible from the top,the cleaning may be done through the appliance tee, clean-out opening, or through the damper (for a fireplace). Debris should then be removed from below. USAGE When wood is burned slowly,it produces tar and other organic vapors which com- bine with expelled moisture to form creosote.These vapors condense in the rela- tively cool flue during slow-burning periods.This results in creosote accumulation on the chimney liner,which is dangerous.If this creosote should ignite,it makes an extremely hot chimney fire which may destroy the corrosion resistance of the stainless steel,and may cause a house fire if flames ignite the roof or nearby com- bustibles. Therefore,we advise homeowners to prevent creosote buildup with safe burning procedures --burn fires hot, not smoldering with a lot of smoke. In a fireplace, keep the top of the flames visible below the fireplace opening;in a woodstove,keep the flames confined to the woodstove itself.Never burn trash,papers,garbage,etc. in a fireplace or woodstove.This could cause a fire hazard and damage the liner. When used for venting solid fuel appliances,this liner must not be smaller than the appliance flue collar unless specified by the appliance manufacturer. Be sure to check the rain cap for icing during low ambient temperatures. 22 MAINTENANCE/WARRANTY WARRANTY CHART" APPLICATION WARRANTY INSULATION REQUIREMENTS Wood,Coal Lifetime warranty Insulation required. See point 3,pages 6,7. Oil,Wood Pellet, Lifetime warranty Insulation recommended Category I Gas (Category I gas only) but not required.See point 3,pages 6,7. *This chart is intended as a quick reference on the warranties—please read the actual written warranty cards for specific details. 23 This Product is Listed by UNDERWRITERS LABORATORIES INC.C UL US LISTED and Bears the Mark: O 2008 Copperfield Chimney Supply HomeSaver®is a registered trademark of Copperfield Chimney Supply 304 South 20th Street,Fairfield,IA 52556 24 (Form No.HD-6I,•f,112) .162 LENNOX- HEATING DATA SHEET JOB NO.. _- DATE__. HEATING CONT1lACTOR *� �S�U ` S_� OUTSIDE DESIGN TEMP.__Q L L ( r # �� ADDRESS �J C GCL~ P. — G"t-1 9q `` INSIDE DESIGN TEMP.. __. _ NAME OF JOB G`G // __.ADDRESSDESIGN TEMP.DIFF._.___ 1. Room Use and Floor Level 1. f v. 2. :- l-_ 3. ;/l c/ ��� 4• ✓ t.✓ 5. 6. 7. 2. Room length and Width �L 4- X ei C7 r k 3. Running F+of Exposed Wall 11, S- .7 12- f- 4. Ceiling Heighf Ir ?, 5. Exposure Lable "V" Multi- Area Area b Area Area Ariarta Area Type No. Factor plier Crack Btuh Cnck Btuh Crack Btuh Crack Btuh Crack LStub os, Crack Bfuh Crack Bfuh Ana Loss Lou Loss Lofl Crack Bfuh C(m �� Cfm Clm Cfm Clm ices Cfm Loss Clm Lou Glm lots Crack Blu/ Groff ,r '� r f Y`)'l �• y�'9 �{1 �LP^:pY �. F`'jr�;•�r: '• `� "ry ��,i '1 •�{�'..•Ss + � i ti-�, Clm Lois 6. Ex!c:ed r.js,`:;' fy� a r4• r. +�._.ijt;y :l;:�yr;. ?: �; r �:3t� ' tip ;}��^% 2y�Y` w Wall ~,~ fi j.` �! a�y A!?( .fit. S6 �.F�• .�'.1..�'� 6 .� j' ;;�Ji� ���y.. ♦' �. );��Y.�? 'Vt' \1��. ♦• t ) < 60 7x 3�o Z x o �o �� �._ c;: �.��,� f/� 3s'9 : �i � * 00 +�'i' '���6t` 3 1 0 Windows _ GD ���_ IZ �v 7. and 1 — Doors G}D 2.0 RIC,0 Net �0 is> Q C oCo q G f2 l 12Q- q v ao S. Exposed - Wall _ 1� _ 14 3 Z 9. Cold Partition — — 10. ColCoiling li .419 in I j23 L 4`� L 3- __ 8_�_�_fP7�_— PvCJ )L, 11. Cold r I 3iZ b Hoor —" Infiltration, 12. (Leakage) or 70 -' Air Change SL �� �O Q� I Z V3 Cj /&C C', A kGp -/' 3v I GO 13. Room Sub-Total Btuh L �-` G L 14. Btuh Adjustment O t ` 0 o 15. Room Total Btuh 2/ 2 t -- Z1 CZ Ica 16. Cfm Temp.Rise Q 17. Adjusted cfm _ L-6 44OX Pquip — �,.,,� Btuh Cfm Y Drires.__..__. Ventilation Loss.- Fuel-- LLl/l� C—A S.P — Rpm Total S —_ APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WR44DSOR PERMIT# Appli h BUILDING DEPARTMENT APP 1540 SULLWAN AVENUE Bldg. l �.L Bldgg.Pee rmit# 644-2511 ext. 230 Date ding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 Sttxt �� �>is �✓o.r '\a Street Lot NO. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt,No. APPLICANT �s r- APPLICANT ADDRESS tw&A APPLICANT'S PHONE# �O ILI .rsc 9 OWNER 9 v/�z^ % l A 1, ILcs•y ApW N 8Fq� OWNER ADDRESS OWNER PHONE CESTIMATED COST$ dj U IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ vl� TYPE OF JOB: �SOR* CO� YNew Installation Alteration/Addition/Repair 20l to 01,� U Revised 03/05/10 . APPLICATION FOR HVAC PERMIT(Continued from ieverse side) TYPE OF STEM: TYPE OF B DING: HEATING ESIDENTIAL ❑ A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ &TEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT.HEATER "EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP OUTSIDE_at_°F INSIDE_ OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) -r4� -OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY{INPUTBTUH) �O NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ ,INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CM (PLANS MUST ACCOMPANY APPLICATION) _ FURTHER DESCRIPTION OF WORK THE UNDERSIG NED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE r ' Al a FOR B1)ILDIM puRp�SES •t � � ; , I r i t � t i ��AN i n' t TOWN OF SOUTH WINDSOR, CT TYPE OF TRANSACTION (Check one) SECTION I-INCIDENT(Com fete for a#Incidents) A 4 NEW REPORT MODIFY REPORT rl DELETE REPORT CIDENT NO. REGION NO. MO DAY YR. DATE OF WEEK ALARM TIME BUILDING NAME AND ADDRESS (Street,City,State,Zip Codel BUILDING NO. 6 C FIXED PROPERTY(Office,warehouse,etc.) Li MOBILE PROPERTY TYPE TYPE OF INCIDENT OCCUPANTS WERE (Check one) C'yriy�/ A 8 C D NOT EVACUATED EVACUATED RELOCATED BOTH B AND C DID HE FIRE DEPAPOTMENT RESPOND?(Check one! FIRE DEPARTMENT FIRE DEPARTMENT E QED VIA RESPONDED WITHIN MIN- YES NO UTES OF NOTIFICATION 891EF HI TORY OF INCIDENT/Cover a#k1portant details-attach additions[sheets as needed. Photos and/or sketches may be ihckrded l F ACTION(S)TAKEN AND RECOMMENDATIONS �JT�O P�REVEN T CRREN `�dlCi( C CLr ^� O `v S�Ur acres NON—C�7OG,A*V7- /VLV,il' ha-'kli?IYC� !`cam d� r/ PERSONNEL NO.OF INJURIES NO.OF DEATHS H GSA �(� ,p OTHER 1 � J !t 1/ �T C $LOSSES �r BUILDING CONTENTS EVACUATION OTHER SECTION If-FIRE(Com fete for all fires) AREA OF FIRE ORIGI EQUIPMENT INVOLVED IN IGNITION oc�o '� 0 FORM OF HEAT OF IGNITION TYPE OF MATERIAL IGNITED FORM OF MATERIAL IGNITED U K A�1 S i� METHOD OF GUISHM LEVEL OF FIRE ORIGIN L � ��7J SECTION III-STRUCTURE FIRE(Complete if structure fires) M TENT OF _ GE �- ` C ENT OF SMOKE DAMAGE N DETECTOR PERFORMANCE SPRINKLER PERFORMANCE IF SMOKE TYPE OF MATERIAL GENERATING MOST SMOKE AVENUE OF SMOKE TRAVEL 0 SPREAD BEYOND FORM OF MATERIAL GENERATING MOST SMOKE P ROOM OF ORIGIN Li SECTION IV-PROPERTY Q MOBILE PROPERTY YR. MAKE MODEL SERIAL NO. LICENSE N (tf any) R EQUIPMENT INVOLVED IN IGNITION YR. MAKE MODEL SERIAL NO. VOLTAGE (if any) SECTION V-PREPARER OF THIS REPORT INVES TO 'S SIGNATURE DATE &Wla ,Svc u�6--. :b's Cy�?'��`:� '�-n�.v/ ' '�i I S cry ►�re�'rtc-f� Electric # Dili%ICATION FOR BUILDING PERMIT Plumbing# 106 Edgewood HVAC# 1000058 Date: S 20 10 Sprinkler# rt; Estimated Cost $ 3 7. .00 FINAL A212 ` Permit Fee $ 100 Building 11 �+ COMPLETE RED BOXED AREAS Occupancy Fee $ to Engineer g TYPE OF PRINT ONLY Eng. Insp. Fee $ AffidavitWIP Appr.for CO. ► SIGN ON REVERSE SIDE t Total Fee $ � TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant ,- LocationofWork .A+1D °r Lot No. Applicants,t4ddress 2 2-0 Cov+� �O Tel # frG 0 - Town 1ro3 Q L err- _Zip Lic.# 14ZC-, Owner TZ o4G o 6A L.D f Q,p IV T_ Architect --- Owner's Address to L C y iac _.ov0 8 tz Architect's Address Zip Zip Sq. Ft.New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit 12G- I, -i e- C4-- %- c 01�i !-rn �1�� City Water fJ Well 0 Septic System J Sewer❑ Ins: HO S ert. Area Basement Garage Approved by lfl Date >,.d-l J Use Group Construction Type Revised I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. Signed�01111AV AFL ra -- I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signev� "w /4 f DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS p..-e�w CKIVIIIIII PIER: PA 17-176 AND 1000058 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 03/08/10 GIS ID:29400106 FEE: 60.00 MUNIS APPLICATION# 201000187 BUILDING DESCRIPTION: APPLICANT" _ LOCATION NAME: CHIMNEY DOCTOR OF CONNECTICUT INC. ADDRESS: 106 EDGEWOOD DRIVE ADDRESS: 220 COOK ROAD t` OWNER: ` 'CALDERONI ROCCO S&JOANNE L PROSPECT,CT 06712 w. " `" ,� � _ 106 EDGEWOOD DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: RE-LINE-CHIMNEY WITH U.L. LISTED STAINLESS STEEL FLEX PIPE. # 1777',�' ,1�-;, c a � 1 •'s SPECIAL CONDITIONS: ' ALL WORK TO BE DONE IN ACCORDANCE WITH THEp APPLICATION AND PLANS'APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: F OCCUPANCY GROUP: BUILDING OFFICIAL 3/8/2010 9:59 AM THE FEE ABOVE INCLUDES A$0.22 PER THOUSAND CT STATE EDUCATION SURCHARGE 1300450 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 10/21/2013 GIS ID:29400106 FEE: 30.00 MUNIS APPLICATION# 201301509 BUILDING DESCRIPTION: APPLICANT - LOCATION NAME: CALDERONI ROCCO S&JOANNE L ADDRESS: .106 EDGEWOOD DRIVE ADDRESS: 106 EDGEWOOD DRIVE OWNER: CALDERONI ROCCO S&JOANNE L SOUTH WINDSOR,CT 06074 327 .106 EDGEWOOD DRIVE "SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALL GAS FIREPLACE IN EXISTING FIREPLACE.,GAS LINE WILL BE DIRECTLY.CONNECTED TO MAIN. EMERGENCY SHUT OFF ON INSIDE SPECIAL CONDITIONS: ` ALL WORK TO BE DONE IN ACCORDANCE WITH THE,APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. r CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 10/21/2013 2:29 PM THE FEE ABOVE INCLUDES A$0.26 PERTHOUSAND CT STATE EDUCATION SURCHARGE 1600445 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 10/28/2016 GIS ID:29400106 FEE: 90.00 MUNIS APPLICATION# 201601540 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: GLASCO HEATING AND`A/C INC ADDRESS: 106 EDGEWOOD DRIVE ADDRESS: 56 GLENDALE ROAD OWNER: CALDERONI JOANNE L TR SOUTH WINDSOR,CT 06074 106 EDGEWOOD DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: GAS BOILER INSTALL. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 10/28/2016 3:25 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE