HomeMy WebLinkAbout104 PINE KNOB DR DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
Application is hereby: TOWN OF SOUTH WINDSOR PERMIT#
BUILDING DEPARTMENT foal 4�
APPR VE 1540 SULLIVAN AVENUE Bldg. Permit#
644-2511 ext. 230
Date Building Inspect
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 Street o. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS L/
APPLICANT PHONE# /-�60 /�
O W N S OWNER '4 Z0&J�y/Z.,d4 (9-/919/Lb 1�
q� OWNER ADDRESS )0//?/zs� )Z-ZL-� 6/<
T cce O /
Oo OWNER PHONE 13(,r) r77
C = ESTIMATED COST$
a
IS THIS A CONTRACT COST? 4��Yes —No
FEE ENCLOSED$
TYPE OF JOB: t7-
OS R•Coy vNew Installation
_Alteration/Addition/Repair
,90ILI6v(�a>s
Revised 4/01//2002
APPLICATION FOR ELECTRICAL PERMIT (continued from reverse side)
TYPE OF BUILD- IS THIS APPLICATION ASSOCIATED WITH A
ING BUILDING PERMIT APPLICATION? ❑ YES�KJNO
rRESIDENTIAL CURRENT USE AND OCCUPANCY
ul❑BUSINESS
❑ASSEMBLY FUTURE USE AND OCCUPANCY
❑MERCANTILE
❑ EDUCATIONAL
❑ INSTITUTIONAL ENGINEER'S NAME PHONE
❑FACTORY
❑ STORAGE ADDRESS
❑GARAGE
❑MIXED USE CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD ( PCJ 6j- ,:�ooj-
SIZE OF SERVICEL O SIZE OF MAIN CONDUCTORS d
NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS
NUMBER OF PANELS ( REMOTE DISCONNECT REQUIRED? ❑YES PO
NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS l
NUMBER OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK. /
32�� . r— /�—
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE / /
Electric # APPLICATION FOR BUILDING PERMIT
Plumbing# �y Pine Knob Drive pc,
HVAC #
Date:
Sprinkler# 328 0 6
FINAL RO S --_-- --- - -- - - - Estimated Cost $
Buildin 0 /! / COMPLETE RED BOXED AREAS Permit Fee $ 9d
Occupancy Fee $
Enginee n TYPE OR PRINT ONLY Eng. Insp. Fee $
Affidavit
for C ► SIGN ON REVERSE SIDE ,o
—- - — - Total Fee $�_
TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant iti Location of Work Lot No.
Applicant's Address Tel.# P,60
Town L i� 627iCi Zip ��'O �y Lic.#
Owner cey/7I f_ Architect
Owner's Address b`.Le25-1 L Architect's Address
Zip Zip
Sq. Ft. New Area: 1 st FI. _2nd FI. 3rd FI. Total New Area
Purpose of this permit je
City Water❑ Well❑ Septic System❑ Sewer❑
Ins: HO P Cert. ea Basement Garage
Approved by Date Use Group - �9tracttbn T�
Revised 6/02
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be locat a proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which t i uilding and i� e Ilowed.
Signed
I hereby apply for a Certificate of Occupancy for the work scribed in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
1
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-32806-B 5,200
B09 OTHER 08/09/07 MR A
B10 FINAL 10/11/07 JFF A
�1'�of
Electric # APPLICATION FOR BUILDING PERMIT
Plumbing# �'1 104 Pine Knob Drive Date: ��
HVAC # _ �
Sprinkler# 29396
Estimated Cost $ zzwC
FINAL AP VAI,S - - -- - Permit Fee $ 3tJ
Building ( COMPLETE RED BOXED AREAS Occupancy Fee $ iv
Engineering TYPE OR PRINT ONLY En Ins •Fee $ b
Affidavit g' p'
Appr. for C Q� SIGN ON REVERSE SIDE Total Fee $ CFO
TO THE B LDING D PAR`TMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant Location of Work 2- Lot No.
Applicant's Address Ze2lv 0/2 Tel.#9O G Y5��07y
Town S 117 S-oZ Zip_ JY Lic.#
Owner .SA/!7s ,vs Architect
Owners Address Architect's Address
Zip Zip
Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area
Purpose of this permit Vllii 4 ,f//�7/ r1aa '
City Water❑ Well[] Septic System Sewer❑
Ins I1O /SP Cert. Area Basement Garage
Approved by .,.30— Date \ �1 0 _ Use Group LL Construction Type �2�
Revised 6102
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be local proper distance from all street lines,side rd lines,and required
distances from all other zones and is located in=whichilding and P,use owed.
Signed
I hereby apply for a Certificate of 7Occu a or the work d application for permit.
Signed
DO NOT WRITE BELOW T LINE
INSPECTION COMMENTS
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
•+-29396-B 2,000
B06 WOOD/GAS STOVE 08/09/07 MR A
1
1
!
i
•s fi
- + n
r•
v'• a;.
Lot Numbers refer to Map Entitled "Subdivision Map
� "'`• �'
Pine Knob Hill S -""• •• "'���ection J. Avery Street, South Windso r •";
Connecticut. Property of I.R.Stich Associates Inc. ^�-µs- T• ^"'� •r
•��• ice. .•��A ,,„„,,�••i•1••
Scale 111•601, April 20, 1959, Revised April- 25, I959..'! _' . _ ;;;,_ ."� _ ` C,J''� �``•
.- - `_IF .. ...i:lam•- .:i..
Building Located as Shown
Proposed_ Layout
Hereon. October 31, 1959 � I.R.Stich A t
ssociates.,Inc'.
• _ Pine-Kneb Hill
t • - ! Pine Knob Drive
Certified substantially correct South. Windsor Connecticut"
Nozonin iolations
g v . +\,. _ S:cale. l"*60'; April 26' 2?J_5
t
a
JUL 0 y 19y�
South Windsor
13UILDING DEPARTMENT
TO THE BUILDING DEPT. TOWN Of SOUTH WINDSOR
certified that this plan and specifications are true
__oji,s of the proposed building or alterations to be
rected at
�31 V��`^t �iM-•Tp street
i,,getber with amendments s ted in application and
,led with plan and I agree to comply with all zoning,
:wilding and state laws and such orders as shall be
isued by the Building Department during pendency
-f this application and final issuance of a building
hermit.
5egned
This plan is P v so ect to the condition that
irders and rdina ces regulating building shall be
a,mplied with.
;onditionally Approved These filed rlth
Clerk
fuilding Inspector
Osts
Ne. .�5 39a
CERTIFICATION OF ZONING COMPLIANCE
Proposed b-uilding;s), use(s) andjor structures)
'Is shc�,rn on this plan appenr(s) to be
;onformance vvth cu.-rent S.,-)-jth
;;gulations. Variances and special excOP".'C'
nay apply.
Date
Ertf r emernt Officer
4.4;
!%rn"V�t NOV."Y'
047
' 'ra toter to' M Entitled
ap
Knob Fine
Vision ap
' Ssction_'I0`_Av 'r'� ' South W:&r*et, "or
c6mecti.cut. S�ale I to 01
April 20 1"9
,
Revised April
I U AM
C4
ijZ
NJ
5PLIT <
Building located as shown Proposed Layout
hereon. October 31 , 1959. I.R.Stich Associates.IZ*iV`.;-..
Pine Knob Hill
Pine Knob Drive.:,
Certified substantially correct
South Windsor, Coact `
No zoning violations. -x
Scale 1"-601, April" .
77
JUN 4 9 1998
South Windsor
BUILDING DEPARTMENT
TO THE BUILDING DEPT. TOWN Of SOUTH WINDSO,
This certified that this plan and specifications are tru.
copies of the proposed building or alterations to bo
erected at
/oy / //�"L �d
� Sfrer
together with amendments stated in application an
filed with plan and I agree to Comply with all ionint
Building and state laws and such orders as :hall o
issued by the Building Department during pendent
Of this applicatio nd final issuance of a buildin.
permit.
Signed
This plan is approved subj t to the condition tha}
orders and ordinances r utahng building shall be
complied with.
Conditionally Approved These filed with
Building Inspector Clerk
Date
CERTIFICATION OF ZONING COMPLIANCE
Proposed building(s), use(s) and/or structures;
�47 as shown on this plan appear(s) to be in
-onformance with current S:D:.jth Wind-.
egulations. Variances and special exception ,
"nay apply.
Date
it�g orcement Officer
e .
LA Numbers refer to Map EntitledIAA
"Subdivision Map, t��p Pine Knob ll .r��: s '' '�
, .At v:
Section 1. Avery &reef, Booth 'wtndaor
Connecticut. Scale 1"-60' April 20,1lS9
Revised April 25, 1959. '
:-R
U Q
• a5Pt/7 <
i
Go. oZ ••,.
Building located as shown - . Proposed Layout �>
hereon. October 31 , 1959. `t` L R.Stich Associates,Ine'.'.
Pine Knob Hill
-l„ ., 4
Pine Knob Drive
Certified substantial) " ' aJ= t
Y correct Z
; South Windsor, Connect(
No zoning violations. <�•, PEj�� Scale 1"-601, April 26;
I'�hA.. � •-�r'r
; � L1 1994
SOUth Windsor
BUILDING DEPARTMENT"
TO �.:E _. ._.1, ..•.. �'_,.iM dtltll�:i
this Bert iti:d thII this plan and specifieationsare tru,
Copies of the proposed building or alteratlotle to br
erected at
� <—j 1 stree,
t,g:ther with amendments stated in application ant,
filed with plin and I agree to Comply with all zoning,
l--10lig and stite laws and such orders as shalt be
Iss,!ed by the Building Department during pendency
of this application d final Issuance of a building
permit.
Signed
I his plan is approved sub' t to the condition that
ordera and erdinances gulating building shall be
C. pliA with.
condttlonaily Approved These Ili
w►to t
building Inspector JJ err
CERTIFICATION OF ZONING COMPLIANCE
Proposed building(s), use(s) and/or structure(s)
Shed as shown on this plan appear(s) to be in
conformance with current South Windsor
regulations. Variances and special exceptions
may apply. (O/a/9
Date ,�)
r� b k'a-
Zoning Enforcement Officer
Ld Numbers refer to Map t:ntitled
"Subdivision Map, Pine Knob Hill
Section 1. Avery Street, South Windsor `
Gonnecticut. Scale 1"•60' April 20, 1959
p- Kevised April 25, 1959. "
4
t
s
G
f 'J
I
• a5P1�T < :jig.;
i•t
Builaing lo( ated as shown Proposed Layout
hereon. October 31 . 1959. •`�. 1. R. Stich Associates, Inc.
' Pine Knob Hill
I-ine Knob Drive
Certified substantially correct South Windsor, Connecticu
No zoning violations. cc;l,*
,S,F i, .. Scale 1 -601, April 26, 19 9
IJU1LU1NU Yx,KMl'1'
STATE OF CONNECTICUT
WORKERS'COMPENSATION COMMISSION
Building Permit Affidavit for Property Owners or Sole Proprietors
(Conn.Gen.S�Stat. §31-286b)
Property located at /�y ���� X17001 ae-
In the town of U �G� L.(�•a��O`�
Name of building permit applicant: i ��7R�n��%G //��/��N
Please checkke.
l. �/ I am the owner of the above property.
2._I am the sole proprietor of a business.
2A.Name of business
213.Federal Employer Identification Number(FEIN)
....................................................................................................................
Pursuant to§31-286b,"a property owner or sole proprietor[who]intends to act as a general
contractor or principal employer"may provide either a certificate of workers'compensation
insurance or a"sworn notarized affidavit... stating that he will require proof of workers'
compensation insurance for all those employed on the job site in accordance with this chapter."
Please check one:
1. I do not int d to act as a general contractor or principal employer.
[Sign a stop here]
Signature of appli
caul
2._I intend to act as a general contractor or principal employer.Applicant must either
provide a certificate of workers'compensation insurance or sign the affidavit
below.
....................................................................................................................
Affidavit
I hereby swear and attest that I will require proof of workers'compensation insurance for every
contractor,subcontractor,or other worker before he/she engages in work on the above property in
accordance with the Workers'Compensation Act(Chapter 568).
I understand that pursuant to§31-275 C.G.S.,officers of a corporation and partners in a
partnership may elect to be excluded from coverage by filing a waiver with the appropriate
District Office;and that a sole proprietor of a business is not required to have coverage unless he
files his intent to accept coverage.
Signature of applicant
Subscribed and sworn to before me this day of ,200 .
(Notary Public/Commissioner of the Superior Court)
w
APPLICATION FOR ELECTRICAL PERMIT
TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT
1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074(PHONE) 860-644-2511 EXT. 230
PERMIT NUMBER:
DEPARTMENT DECISION
APPL1 REBY: �(
APPRO BLDG.PERMIT NUMBER:
2�
DATE OR
LOCATION OF WORK: I OLl t i) k'(\ob �N\\Jp-
APPLICANT: OWNER: TYPE OF STRUCTURE:
o NEW BUILDING
NAME; Trinity Solar NAME: ?)Y►QY1 ��( o ADDmON
PHONE NUMBER: 203-701-3724 PHONE NUMBER: � 03� 5 U58 G9 EXISTING BUMDING
ADDRESS: 7 McKee Place ADDRESS:1.OL( �N'(1P wtb dmi
Cheshire,CT 06410 TYPE OF USE:
0RESMENTIAl. ❑COMWERCIAL
ELECTRICAL INFORMATION: FURTHER DESCRIPTION OF WORK:
TYPE OF INSTALLATION: installation of roof mounted solar pancls,� kW.
SIZE OF SERVICE:
SIZE OF MAIN SERVICE:
NUMBER OF METERS:
NUMBER OF PANELS:
NUMBER OF LIGHT CIRCUITS: ESTIMATED COST: ' `�Ll fj
NUMBER OF SWITCHES:
°u NUMBER OF LIGHT FIXTURES: FEE ENCLOSED: `-I a .
NUMBER OF A/C CIRCUITS:
FEE SCHEDULE:SIS PER S1,000 OF THE ESTIMATED COST.
NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS
NUMBER OF OUTLETS: $1.00 OVER. (.26 CENT EDUCATIONAL FEE INCLUDED AS PART
OF THE PERMIT FEE)
THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL
ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO.: 0195559 TYPE: E1 STATE: CT ,`\�
SIGNATURE OF APPLICANT: DATE: � l b�V
90'a000304
.�. WESTSHORE
WA)
DESIGN ENGINEERS, P.C.
- 100 GREAT OAKS BLVD. I SUITE 115
ALBANY NEW YORK 1 12203
To: Trinity Solar
7 McKee Place
Cheshire, CT 06410
Date: February 4, 2020
Ref.. 20020104
Subject: Brian Forte
104 Pine Knob Dr.
South Windsor, CT
Dear Trinity Solar,
The following references the Brian Forte residence in South Windsor, CT:
1 Existing roof framing:
Roofs 1&4: Conventional framing is 2x6 at 16"o.c. with a 13'-8" max. span (horizontal rafter
projection). This existing structure is capable to support all the loads that are indicated below for
this photovoltaic project
2. Roof Loading
4.33psf dead load (modules plus mounting hardware)
30psf ground snow load
5.7psf roof materials (1.7psf 2x6, 1.5psf sheathing, 2.5psf asphalt shingles)
Exposure Category B, 135mph wind gust(3 sec.)
This installation genera
design will be in l conformance to the manufacturer's
g b acturer s specifications,and complies
P p
with all applicable laws, codes, and ordinances, and 2018 State CT Building Code, International
Residential Code/IRC 2015. The spacing and fastening of the mounting brackets is to have a maximum
of 48"o.c. span between mounting brackets, staggered, and secured using 5/16" diameter corrosive
resistant steel lag bolts. A minimum of 2.5" of penetration per lag bolt is required, which is adequate to
resist all 125mph wind live loads including wind shear. Per NDS Section 11.1.4 clearance holes equal to
the diameter of the shank need to be bored into a primary framing member for the full length to the
threaded portion of the screw to avoid splitting of the framing member.
Thank you.
Westshore Design Engineers
```��ttlttilr�����
�� F 0 CIV....... ......N
NO.32451
$s/ONA�0%���
Exp.1.31.21
2/4/2020
John Eibert Nicolas Nitti, PE
Project Coordinator President
WestShore Design Engineers 1 100 Great Oaks Blvd.I Suite 115 1 Albany,NY 12203 1518.313.7153
A�f® CERTIFICATE OF LIABILITY INSURANCE DA 2r�ono,�s
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on
this certificate does not confer rights to the certificate holder in lieu of such endorsement(s)
PRODUCER CONTACT
NAME: Mark Grasela
Arthur J.Gallagher Risk Management Services,Inc. PHONE 856 482-9900 F c No 856 482-1888
4000 Midlantic Drive Suite 200 E-MAIL
Mount Laurel NJ 08054 ADDRESS: CherryHill.BSD.CertM@AJG.com
INSURERS AFFORDING COVERAGE NAIC N
INSURER A:American Guarantee and Liability Ins Co 26247
INSURED TRINHFA-03 INSURER 8:Gotham Insurance Company 25569
Trinity Heating&Air,Inc.DBA Trinity Solar
611 W JOHNSON AVE INSURER C:National Union Fire Insurance Company of Pittsburg19445
CHESHIRE,CT 06410 INSURER D:Liberty International Underwriters
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER:1506993838 REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MM//DDY EFF MPM/D EXP
D/ UNITS
LTR
B X COMMERCIAL GENERAL UABILITY GL201900013378 12/312019 6/1/2021 EACH OCCURRENCE s2,000,000
GE TO RENTED
CLAIMS-MADE �OCCUR PREMISES Ea occurrence $100,000
MED EXP(Any one person $5,000
PERSONAL 3 ADV INJURY $1,000,000
GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE S 2,000,000
POLICY a PRO-
JET LOC PRODUCTS-COMP/OP AGG $2,000,000
OTHER: S
C AUTOMOBILE LIABILITY CA 2960141 12/31/2019 6/1/2020 COMBINED SINGLE LIMIT Ea cddent
$2,000,000
e
X ANY AUTO BODILY INJURY(Per person) $
OWNED SCHEDULED BODILY INJURY(Per accident) $
AUTOS ONLY AUTOS
HIRED NON-OWNED PROPERTY DAMAGE $
1AUTOS ONLY AUTOS ONLY Per accident
$
n
UMBRELLALIAR X OCCUR UM2019D0008887 12/31/2019 6/1/2021 EACH OCCURRENCE $5,000,000
D X EXCESS LIAR AEC 1448324-01 12/31/2019 6/l2021
CLAIMS-MADE 1000231834-04 12/31/2019 6/12021 AGGREGATE $5.000,000
DED RETENTION$ Limit z of S5,000,000 $19,000,000
C WORKERS COMPENSATION WC 13588107 12/31/2019 6IM020 PER OTH-
AND EMPLOYERS'LIABILITY YIN STATUTE ER
ANYPROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E.L.EACH ACCIDENT $1.000,000
OFFICER/MEMBEREXCLUDED7
(Mandatory In NH) E.L.DISEASE-EA EMPLOYEE f 1.000,000
If yes,describe under
DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000.000
C Automobile CA 2960141 12/3112019 6/12020 Al Other Units $250/500
Comp/Collusion Ded. Truck-Tractors and
Semi-Traders $250/500
DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached it mom space Is required)
Evidence of Insurance.
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
ACCORDANCE WITH THE POLICY PROVISIONS.
Evidence of Insurance
AUTHORIZED REPRESENTATIVE
V4 I.zr-�)
01988.2015 ACORD CORPORATION. All rights reserved.
ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD
INSTALLATION OF NEW PINE KNOB DRIVE.
ROOF MOUNTED PV SOLAR SYSTEM
104 PINE KNOB DRIVE
— JF�Tn
SOUTH WIN DSO R, CT 06074
{
Issued/Revisions
f
Pt ISSUED TO TOWNSHiPE OR PERMIT )/7/)020
VICINITY MAP J CITEL NO. DESCRIPTION DATE
SCALE: NTS Project Title:
FORTE,BRIAN
TRINITY ACCT M 2020-01-407021
Project Address:
104 PINE KNOB DRIVE
SOUTH WINDSOR,CT 06074
41.834264,-72.509856
GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX
Drawing Title:
1. THE INSTALLATION CONTRACTOR IS B. THE DC VOLTAGE FROM THE PANELS IS 14. B)CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES
RESPONSIBLE FOR INSTALLING ALL EQUIPMENT ALWAYS PRESENT AT THE DC DISCONNECT COMPANY SPECIFICATIONS,STANDARDS, kCMIL THOUSAND CIRCULAR MILS
AND FOLLOWING ALL DIRECTIONS AND ENCLOSURE AND THE DC TERMINALS OF THE AND REQUIREMENTS IkVA kw KILO-VOL TAMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM
INSTRUCTIONS CONTAINED IN THE DRAWING INVERTER DURING DAYLIGHT HOURS.ALL 15 THIS SET OF PLANS HAVE BEEN PREPARED
PACKAGE AND INFORMATION RECEIVED FROM PERSONS WORKING ON OR INVOLVED WITH FOR THE PURPOSE OF MUNICIPAL AND kWH KILO-WATT HOUR P V-3 ELECTRICAL 3 LINE DIAGRAM
TRINITY. THE PHOTOVOLTAIC SYSTEM ARE WARNED AGENCY REVIEW AND APPROVAL.THIS SET L LINE
2. THE INSTALLATION CONTRACTOR IS THAT THE SOLAR MODULES ARE ENERGIZED OF PLANS SHALL NOT BE UTILIZED AS MCB MAIN CIRCUIT BREAKER q p APPENDIX DrawingInformation
RESPONSIBLE FOR INSTALLING ALL EQUIPMENT WHENEVER THEY ARE EXPOSED TO LIGHT. CONSTRUCTION DRAWINGS UNTIL REVISED MDP MAIN DISTRIBUTION PANEL
AND FOLLOWING ALL DIRECTIONS AND 9. ALL PORTIONS OF THIS SOLAR TO INDICATE"ISSUED FOR CONSTRUCTION". MLO MAIN LUG ONLY DRAWING DATE: 2/7/2020
INSTRUCTION CONTAINED IN THE COMPLETE PHOTOVOLTAIC SYSTEM SHALL BE MARKED 16 ALL INFORMATION SHOWN MUST BE MTD MOUNTED DRAWN BY: JC
MANUAL. CLEARLY IN ACCORDANCE WITH THE CERTIFIED PRIOR TO USE FOR MTG MOUNTING REVISED BY:
3. THE INSTALLATION CONTRACTOR IS NATIONAL ELECTRICAL CODE ARTICLE 690& CONSTRUCTION ACTIVITIES. N NEUTRAL
RESPONSIBLE FOR READING AND 705. NEC NATIONAL ELECTRICAL CODE
UNDERSTANDING ALL DRAWINGS,COMPONENT 10. PRIOR TO THE INSTALLATION OF THIS NIC NOT IN CONTRACT
AND INVERTER MANUALS PRIOR TO PHOTOVOLTAIC SYSTEM,THE INSTALLATION NO a NUMBER System Information:
INSTALLATION.THE INSTALLATION CONTRACTOR SHALL ATTEND A ABBREVIATIONS NITS NOT TO SCALE DC SYSTEM SIZE: 6.3kW
CONTRACTOR IS ALSO REQUIRED TO HAVE ALL PRE-INSTALLTION MEETING FOR THE REVIEW OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: SkW
COMPONENT SWITCHES IN THE OFF POSITION OF THE INSTALLATION PROCEDURES, AMP AMPERE p POLE
AND FUSES REMOVED PRIOR TO THE SCHEDULES,SAFETY AND COORDINATION. AC ALTERNATING CURRENT PB PULL BOX TOTAL MODULE COUNT: 20
INSTALLATION OF ALL FUSE BEARING SYSTEM 11. PRIOR TO THE SYSTEM START UP THE AL ALUMINUM pH 0 PHASE MODULES USED: HANWHA 315
FRAME
COMPONENTS. INSTALLATION CONTRACTOR SHALL ASSIST IN AF AMP. pVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC N: Q.PIAK DUO BlK-GS 315
4. ONCE THE PHOTOVOLTAIC MODULES ARE PERFORMING ALL INITIAL HARDWARE AFF ABOVE FINISHED FLOOR Q yR POWER
RCE
MOUNTED,THE INSTALLATION CONTRACTOR CHECKS AND DC WIRING CONDUCTIVITY AFG ABOVE FINISHED GRADE RGS QUANTITY UTILITY COMPANY: 516930EVERSO 804
AWG AMERICAN WIRE GAUGE RIGID GALVANIZED STEEL UTILITY ACCT K: 51693028045
SHOULD HAVE A MINIMUM OF ONE CHECKS. RGS
C CONDUIT(GENERIC TERM OF SOLID NEUTRAL UTILITY METER N: 893815662
ELECTRICIAN WHO HAS ATTENDED A SOLAR 12, FOR THE PROPER MAINTENANCE AND SN
PHOTOVOLTAIC INSTALLATION COURSE ON SITE. ISOLATION OF THE INVERTERS REFER TO THE RACEWAY,PROVIDE AS SPECIFIED) J5VJBD SWITCHBOARD DEAL TYPE: SUNNOVA
5. FOR SAFETY,IT IS RECOMMENDED THAT THE ISOLATION PROCEDURES IN THE OPERATION COMBINER BOX Typ TYPICAL
INSTALLATION CREW ALWAYS HAVE A MANUAL. CB CIRCUIT U.O.I. UNLESS OTHERWISE INDICATED
MINIMUM OF TWO PERSONS WORKING 13. THE LOCATION OF PROPOSED ELECTRIC AND CKT CURRENT TRANSFORMER yyp WEATHERPROOF
TOGETHER AND THAT EACH OF THE TELEPHONE UTILITIES ARE SUBJECT TO FINAL CT COPPER XFMR TRANSFORMER
CU DIRECT CURRENT Rev.No. Sheet
INSTALLATION CREW MEMBERS BE TRAINED IN APPROVAL OF THE APPROPRIATE UTILITY +72 MOUNT IN INCHES TO BOTTOM OF
FIRST AID AND CPR. COMPANIES AND OWNERS. DI DISCONNECT SWITCH ABOVE FINISHED FLOOR OR GRADE
6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO BE 14. ALL MATERIALS,WORKMANSHIP AND DISC DRAWING P 1 P V 1
INSTALLED FOLLOWING THE CONVENTIONS OF CONSTRUCTION FOR THE SITE DWG ELECTRICAL SYSTEM INSTALLER
THE NATIONAL ELECTRICAL CODE. ANY LOCAL IMPROVEMENTS SHOWN HEREIN SHALL BE EC ELECTRICAL METALLIC TUBING
CODE WHICH MAY SUPERSEDE THE NEC SHALL IN ACCORDANCE WITH: EMT FUSIBLE SWITCH
GOVERN. A)CURRENT PREVAILING MUNICIPAL FU FS FUSE
7. ALL SYSTEM COMPONENTS TO BE INSTALLED AND/OR COUNTY SPECIFICATIONS, G GROUND
WITH THIS SYSTEM ARE TO BE"UL"LISTED.ALL STANDARDS AND REQUIREMENTS ND GROUND FAULT INTERRUPTER
GFI FREQUENCY(CYCLES PER SECOND) Aft
EQUIPMENT WILL BE NEMA 311 OUTDOOR HZ �
RATED UNLESS INDOORS. Trt 0
9
GENERAL NOTES S O L A R
IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT, 2211 Allenwood Road 877-786-7283
Wall,New Jersey 07719 www.Tnnrty-Solar.com
NOTES:*REFER TO MODULE SPECS FOR MODULE DIMENSIONS
*DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE UNIRAC CLAMP
NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS)
(REFER TO EQUIPMENT SCHEDULE FOR
SPECS AND QUANTITIES)
SOLAR MODULE SOLAR MODULE
NEW MOUNTING FOOT/ATTACHMENT
POINTS,TYPICAL(REFERTO
ENGINEERING LETTER FOR SPACING AND UNIRAC"L'FOOT UNIRAC RAIL _
DETAILS) to (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) M ryry 2'
NEW UNIRAC RAIL,TYPICAL ;n I
TO BE MOUNTED PERPINDICULARTO UNIRAC FLASHING:::::�� EXISTING ASPHALT SHINGLES _
STRUCTURE(REFERTOUNIRAC (REFER TO SPEC SHEET FOR DETAILS) (REFER TO ENGINEERS LETTER FOR SPECS) N n
y
SPECIFICATION/DATA SHEET FOR
DETAILS)
NEW END CUP,TYPICAL S.S.LAG BOLT—� APOC SEALANT �£� i/\\
_♦ _ _• (REFER TO UNIRAC SPECIFICATION/ SOLAR MODULES SHALL NOT
DATA SHEET FOR DETAILS) EXISTING RAFTER EXCEED PEAK HEIGHT.
(REFER TO ENGINEERS LETTER FOR SPECIFICATION
NEW MID CUP,TYPICAL
(REFER TO UNIRAC SPECIFICATION/
DATA SHEET FOR DETAILS)
nATTACHMENT&CLIP DETAIL nPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF
SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE
ARRAY SCHEDULE
Issued/Revisions
12 ISSUEOTOTO SHIP FORPERNT 2nnom
NO. DESCRIPTION DATE
Project Title:
(PROPERTY LINE) FORTE,BRIAN
TRINITY ACCT#:2020-01-407021
Project Address:
j F R Rl R2 104 PINE KNOB DRIVE
■
U o R N SOUTH WINDSOR,CT 06074
ED
LL 41.834264,-72.509856
a
0
o Drawing Title:
U ~
Rg PROPOSED PV SOLAR SYSTEM
Drawing Information
DRAWING DATE: 2/7/2020
DGR.UN
DRAWN BY: 1C
REVISED BY:
EP R S stem Information:
ROOF1AC M DC SYSTEM SIZE: 6.3kWMODULES:17 DC AC SYSTEM SIZE: 5kW
PITCH:23
ORIENTATION:202
TOTAL MODULE COUNT: 20
ROOF 2 MODULES USED: HANWHA 315
MODULES:0 MODULE SPEC M Q.PEAK DUO BLK-GS 315
PITCH:23'
ORIENTATION:22' UTIUTYCOMPANY: EVERSOURCE
ROOF 3 UTILITY ACCr#: 51693028045
MODULES:0 NOTES:
PITCH:23' UTILITY METER#: 893815662
ORIENTATION:22' 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DFALTYPE: SUNNOVA
ROOF 4 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
MODULES:3 2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION.
PITCH.23
3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION.
ORIENTATION:112 4.)AN AC DISCONNECT SHALL BE GROUPED WITH INVERTERS)NEC 690.13(E). Rev.N0. SheeL
ROOFS S.)ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
P Hu 23'0 6.)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE ^ ` ,
ORIENTATION:202' i P V 2
ROOF6 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE 1 1
MODULES:0 QTY SPEC#
PITCH:23' INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL
ORIENTATION:206' Rl ARRAY SCHEDULE FOR MORE INFORMATION INSTALLED OUTSIDE(UTILITY ACCESSIBLE) SP TO BE INSTALLED 20 HANWHA 31S(Q.PEAK DUO BLK-GS 315)
ROOF7
PITCH:23'MODULES:0 INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SES000H-US0008NC4
ORIENTATION:26' i M ) INDICATES EXISTING METER LOCATION � INDICATE PANELS THAT USE MICRO INVERTERS.REFER )
ttt 111 TO EQUIPMENT SCHEDULE FOR SPECS.
ROOFS
MOODULES:0 OTHER OBSTRUCTIONS
PITCH:22' INDICATES EXISTING ELECTRICAL PANEL LOCATION: INDICATES NEW PRODUCTION METER TO BE INSTALLED
— - im
ORIENTATION:292' EP INSIDE P OUTSIDE.
ROOF9 SOLAR
MODULES:0
PITCH:23' INDICATES NEW FUSED PV DISCONNECT TO BE INDICATES NEW INVERTER TO BE
ORIENTATION:202' ® INSTALLED OUTSIDE. Wall,New llenwood
077oad Sty-olar.c 83
INSTALLED CIUTSIDE(UTIUTYACCESSIBLE) A Wall, 07719 www.Trinity-Solar.com TO EQUIPMENT SCHEDULE FOR SPECS y F[y-Solar.com
Engineer/License Holder:
ARRAY CIRCUIT WIRING NOTES
LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2017 SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS — -
20-315W MODULES W/1 SOLAR EDGE P320 PER MODULE
2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO 2 STRINGS OF 10 MODULES IN SERIES-380 Vmax --- ------ JUNCTION —i
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT F BOX 1
TEMP=-16'C '2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1
I
3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED I
ON ASHRAE HIGHEST MONTH 2%DRY BULB 1
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO 1
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= I
33'C I
4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN
TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED
STATES(PALM SPRINGS,CA IS 44.1-C). FOR LESS THAN 9 I
CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED I Issued/Revisions
SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING 1
THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS I
(ALL OF UNITED STATES)
5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I P1 1S [O TO TOWNSHIP FM PERM9 1nno2o
NEC 690.12(A)THROUGH(D)
NO. DESCRIPTION DATE
6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title:
SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4)
7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE 1 FORTE,BRIAN
I
IDENTIFIED WITH THE FOLLOWING OUTER FINISH:
POSITIVE CONDUCTORS=RED I TRINITY ACCT#:2020-01-407021
NEGATIVE CONDUCTORS=BLACK
NEC210.5(C)(2) I Project Address:
8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE 410 PV EXISTING 240V 10 NOTE' I
WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE 10 120/240V 200A MAIN BREAKER INTERNAL REVENUE GRADE MONITORING I 104 PINE KNOB DRIVE
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT UTILITY METER 200A BUSBAR CONTAINED WITHIN SOLAR EDGE INVERTER I SOUTH WINDSOR,CT 06074
SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24'SHALL SOLAR EDGE PN.RWND-3D-240-MB I 41.834264,72.509856
CONTAIN 5 20 CURRENT CARYING CONDUCTORS AND
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN 5
9 CURRENT CARRYING CONDUCTORS.
Drawing Title:
9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS a3
OTHERWISE NOTED
I
10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON
PROPOSED PV SOLAR SYSTEM
ROOFTOP AND SHALL BE LIMITED TO 12'IF USED
OUTDOORS D
INVERTER#1
11.)OVERCURRENT PROTECTION FOR CONDUCTORS Drawing Information
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE ———n+ I DRAWING DATE: 2/7/2020
LOCATED WITHIN 10'Of THE POINT OF CONNECTION NEC i I DRAWN BY: JC
70S.31 — —
m e �� > I REVISED BY:
12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A m L m t o J
UTILITY AND THE OTHER AN INVERTER,PV BACKFEED Ll L2 N r
BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY f --- e e ----- — — — — — — — — — — — — — -------------- =i System Information:
NEC 705.12(8)(2)(3)(b) C f II I DC SYSTEM SIZE: 6.3kW
EXISTING MAIN BREAKER LOAD I� L.,/(--------J AC SYSTEM SIZE: SkW
13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY CENTER I'-- —
————--——J TOTAL MODULE COUNT: 20
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR 2p30A BACK FEED BREAKER
LOADS NEC705.12(B) MODULES USED: HANWHA315
MODULE SPEC#: CLPEAK DUO BLK-GS 315
14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
A NEMA 3R RATING UTILITY COMPANY: EVERSOURCE
UTILITY ACCr#: 51693028045
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER#: 893815662
REQUIRED CONDUCTOR AMPACITY PERSTRING- DEALTYPE: SUNNOVA
[NEC 690.8(6)(1)1:(15.00'1.25)1=18.75A
PV MODULE SPECIFICATIONS
AWG#10,DERATED AMPACITY HANWHA 315(Q.PEAK DUO BLK-GS 315)
AMBIENT TEMP:33'C,TEMP DERATING FACTOR:.96 Rev.No. Sheet
RACEWAY DEBATING=4 CCC:0.90 Imp 9.41 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
(40'.96)0.80=30.72A Vmp 33.46 TO MEET OR EXCEED NEC AND LOCAL AH1D REQUIREMENTS
30.72A'-18.75A,THEREFORE WIRE SIZE IS VALID Voc 40.29 A 46THWN-2 GECTO EXISTING GROUND ROD P 1 PV 3
TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 9.89 B 3/4"CONDUIT W/2410 THWN-2,1410 THWN-2,1-#10 THWN-2 GROUND
21.00A'1.25=26.25A
C 3/4"CONDUIT W/4-#10THWN-2,1-410THWN-2GROUND
AWG#10,DERATED AMPACITY INVERTER#1-SE5000H-USOOOBNC4 r
AMBIENT TEMP:30'C,TEMPDERATING:1.0 D 3/4"CONDUITW/4-#10THWN-2,1-410THWN-2GROUND
RACEWAY DEBATING`_3 CCC:N/A DC AC 0
40A'1.0=40A Imp 13.5 Pout g26.25
E 3/4"CONDUITW/2Jt10THWN-2,1#lOTHWN-2,1#10THWN-2GROUND40A'_26.25A,THEREFORE AC WIRE 512E IS VAUD Vmp 380 Imax Voc 480 OCPDmin F #10 PV WIRE(FREE AIR)W/#8 BARE COPPER BOND TO ARRAY
CALCULATION FOR PV OVERCURRENT PROTECTION SOLAR
AADY
TOTAL INVERTER CURRENT: 1.00A Isc 30 Vnom
21.00A'1.25=26.25A 2211 Allenwood Road 977-786-7283
—>30A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 www.Trinity-Solar.com
INSTALLATION OF NEW PINE KNOB DRIVE.
ROOF MOUNTED PV SOLAR SYSTEM
104 PINE KNOB DRIVE
SOUTH WIN DSO R, CT 06074
Issued/Revisions
Pl ISSUEO i0 ipNMSHIP FON PFMMII l/]/}0]0
VICINITY MAP SITE NO. DESCRIPTION DATE
SCALE: NTS Project Title:
FORTE,BRIAN
TRINITY ACCT M 2020-01-407021
I
Project Address:
104 PINE KNOB DRIVE
SOUTH WINDSOR,CT 06074
41.834264,-72.509856
GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SH E ET I N D EX
Drawing Title:
1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B)CURRENT PREVAILING UTILITY 1B MIL JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES
RESPONSIBLE FOR INSTALLING ALL EQUIPMENT ALWAYS PRESENT AT THE DC DISCONNECT COMPANY SPECIFICATIONS,STANDARDS, kC THOUSAND CIRCULAR MILS ^^��
AND FOLLOWING ALL DIRECTIONS AND ENCLOSURE AND THE DC TERMINALS OF THE AND REQUIREMENTS kVA KILO-VOLT AMPERE PV—L ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM
INSTRUCTIONS CONTAINED IN THE DRAWING INVERTER DURING DAYLIGHT HOURS.ALL 15 THIS SET OF PLANS HAVE BEEN PREPARED kW KILO-WATT
PACKAGE AND INFORMATION RECEIVED FROM PERSONS WORKING ON OR INVOLVED WITH FOR THE PURPOSE OF MUNICIPAL AND kWH KILO-LINE WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM
TRINITY. THE PHOTOVOLTAIC SYSTEM ARE WARNED AGENCY REVIEW AND APPROVAL.THIS SET L
2. THE INSTALLATION CONTRACTOR IS THAT THE SOLAR MODULES ARE ENERGIZED OF PLANS SHALL NOT BE UTILIZED AS MCB MAIN CIRCUIT BREAKER
RESPONSIBLE FOR INSTALLING ALL EQUIPMENT WHENEVER THEY ARE EXPOSED TO LIGHT. CONSTRUCTION DRAWINGS UNTIL REVISED MDP MAIN DISTRIBUTION PANEL AP APPENDIX Drawin Information
AND FOLLOWING ALL DIRECTIONS AND 9. ALL PORTIONS OF THIS SOLAR TO INDICATE"ISSUED FOR CONSTRUCTION'. MLO MAIN LUG ONLY DRAWING DATE: 2/7/2020
INSTRUCTION CONTAINED IN THE COMPLETE PHOTOVOLTAIC SYSTEM SHALL BE MARKED 16 ALL INFORMATION SHOWN MUST BE MTD MOUNTED DRAWN BY: 1C
MANUAL. CLEARLY IN ACCORDANCE WITH THE CERTIFIED PRIOR TO USE FOR MTG MOUNTING REVISED BY:
3. THE INSTALLATION CONTRACTOR IS NATIONAL ELECTRICAL CODE ARTICLE 690& CONSTRUCTION ACTIVITIES. N NEUTRAL
RESPONSIBLE FOR READING AND 705. NEC NATIONAL ELECTRICAL CODE
UNDERSTANDING ALL DRAWINGS,COMPONENT 10. PRIOR TO THE INSTALLATION OF THIS NIC NOT IN CONTRACT
AND INVERTER MANUALS PRIOR TO PHOTOVOLTAIC SYSTEM,THE INSTALLATION NO a NUMBER System Information:
INSTALLATION.THE INSTALLATION CONTRACTOR SHALL ATTEND A ABBREVIATIONS NTS NOT TO SCALE DC SYSTEM SIZE: 63kW
CONTRACTOR IS ALSO REQUIRED TO HAVE ALL PRE-INSTALLTION MEETING FOR THE REVIEW AMP AMPERE OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: SkW
COMPONENT SWITCHES IN THE OFF POSITION OF THE INSTALLATION PROCEDURES, P POLE
AC ALTERNATING CURRENT TOTAL MODULE COUNT: 20
AND FUSES REMOVED PRIOR TO THE SCHEDULES,SAFETY AND COORDINATION. PB PULL BOX
INSTALLATION OF ALL FUSE BEARING SYSTEM 11. PRIOR TO THE SYSTEM START UP THE AL ALUMINUM pH PHASE MODULES USED: HANWHA 315
FRAME
COMPONENTS. INSTALLATION CONTRACTOR SHALL ASSIST IN AF AMP. PVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC p: q.PEAK DUO BLK-GS 315
SHED FLOOR N II
4. ONCE THE PHOTOVOLTAIC MODULES ARE PERFORMING ALL INITIAL HARDWARE AFF ABOVE F AFG ABOVE F I N I SHED GRADE PWR POWER
UTILITY COMPANY: EVERSOURCE
MOUNTED,THE INSTALLATION CONTRACTOR CHECKS AND DC WIRING CONDUCTIVITY CITY QUANTITY
SHOULD HAVE A MINIMUM OF ONE CHECKS. C CONDUIT
AWG AMERICAN WIRE GAUGEGENERIC TERM OF FIGS RIGID GALVANIZED STEEL UTILITY ACCT R: 51693028045
ELECTRICIAN WHO HAS ATTENDED A SOLAR 12. FOR THE PROPER MAINTENANCE AND ( SN SOLID NEUTRAL UTILITY METER N: 893815662
PHOTOVOLTAIC INSTALLATION COURSE ON SITE. ISOLATION OF THE INVERTERS REFER TO THE RACEWAY,PROVIDE AS SPECIFIED) JSVVBD SWITCHBOARD DEAL TYPE: SUNNOVA
S. FOR SAFETY,IT IS RECOMMENDED THAT THE ISOLATION PROCEDURES IN THE OPERATION COMBINER BOX Typ TYPICAL
INSTALLATION CREW ALWAYS HAVE A MANUAL. CB CIRCUITU.O.I. UNLESS OTHERWISE INDICATED
MINIMUM OF TWO PERSONS WORKING 13. THE LOCATION OF PROPOSED ELECTRIC AND CKT CURRENT TRANSFORMER yyp WEATHERPROOF
TOGETHER AND THAT EACH OF THE TELEPHONE UTILITIES ARE SUBJECT TO FINAL CT COPPER XFMR TRANSFORMER
INSTALLATION CREW MEMBERS BE TRAINED IN APPROVAL OF THE APPROPRIATE UTILITY CU DIRECT CURRENT +72 MOUNT 72 INCHES TO BOTTOM OF Rev.No. Sheet
FIRST AID AND CPR. COMPANIES AND OWNERS. DC DISCONNECT SWITCH ABOVE FINISHED FLOOR OR GRADE
6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO BE 14. ALL MATERIALS,WORKMANSHIP AND DISC DRAWING (� /
INSTALLED FOLLOWING THE CONVENTIONS OF CONSTRUCTION FOR THE SITE DWG ELECTRICAL SYSTEM INSTALLER p 1V V
THE NATIONAL ELECTRICAL CODE. ANY LOCAL IMPROVEMENTS SHOWN HEREIN SHALL BE EC ELECTRICAL METALLIC TUBING
CODE WHICH MAY SUPERSEDE THE NEC SHALL IN ACCORDANCE WITH: EMT FUSIBLE SWITCH
GOVERN. A)CURRENT PREVAILING MUNICIPAL FU FS FUSE
7. ALL SYSTEM COMPONENTS TO BE INSTALLED AND/OR COUNTY SPECIFICATIONS, GROUND
G
WITH THIS SYSTEM ARE TO BE"UL"LISTED.ALL STANDARDS AND REQUIREMENTS ND GROUND FAULT INTERRUPTER
EQUIPMENT WILL BE NEMA 3R OUTDOOR HZI FREQUENCY(CYCLES PER SECOND)
RATED UNLESS INDOORS. Tr i In I t (2)
GENERAL NOTES S O L A R
IF ISSUED DRAWING 15 MARKED WITH A REVISION CHARACTER OTHER THAN"A`,PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Allenwood Road 877-786-7283
Wall,New Jersey 07719 www.Trinity-Solar.com
NOTES:*REFER TO MODULE SPECS FOR MODULE DIMENSIONS
*DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE UNIRAC CLAMP
NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS)
qft
(REFER TO EQUIPMENT SCHEDULE FOR
SPECS AND QUANTITIES) SOLAR MODULE SOLAR MODULE
NEW MOUNTING FOOT/ATTACHMENT t.
��+ /
POINTS,TYPICAL(REFER TO
UNIRAC"L'FOOT UNIRAC RAIL
ENGINEERING LETTER FOR SPACING AND - x - i
DETAILS) Tp � (REFER TO SPEC SHEET FOR DETAILS) (REFER TOSPEC SHEET FOR DETAILS) O \� ,
NEW UNIRAC RAIL,TYPICAL
TO BE MOUNTED PERPINDICULAR TO UNIRAC FLASHING EXISTING ASPHALT SHINGLES
STRUCTURE(REFER TO UNIRAC (REFER TO SPEC SHEET FOR DETAILS) (REFER TO ENGINEERS LETTER FOR SPECS)
SPECIFICATION/DATA SHEET FOR :::��
DETAILS) I
11
/��Pi Ob
NEW ENO CUP,TYPICAL S.S.LAG BOLT- APOC SEALANT(REFE \
Imo♦ DATA SHEETO T
FDEEMSPECIFICATION/ / )
DATA SHEET FOR DETAILS) SOLAR MODULES SHALL NOT
EXISTING RAFTER EXCEED PEAK HEIGHT.
NEW MID CLIP,TYPICAL (REFER TO ENGINEERS LETTER FOR SPECIFICATION
(REFER TO UNIRAC SPECIFICATION/
DATA SHEET FOR DETAILS)nATTACHMENT&CLIP DETAIL nPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF
SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE
ARRAY SCHEDULE Issued/Revisions
1`7 ISSUED TO TOWMSHM FOR PERMR 2/7/2020
NO. DESCRIPTION DATE
Project Title:
(PROPERTY LINE I FORTE,BRIAN
TRINITY ACCT N:2020-01-407021
I
Project Address:
R R 104 PINE KNOB DRIVE
Z R y SOUTH WINDSOR,CT 06074
< R 41.834264,72.509856
a o
m LL
_ u
o Drawing Title:
9 R PROPOSED PV SOLAR SYSTEM
Drawing Information
DRAWING DATE: 2/7/2020
FGRO
DRAWN BY: JC
REVISED BY:
R EP R S stem Information:
ROOF1N AC M DC SYSTEM SIZE: 6.3kW
MODULES:17 SS DC AC SYSTEM SIZE: SkW
PITCH:23
ORIENTATION:202 TOTAL MODULE COUNT: 20
ROOF 2 MODULES USED: HANWHA 315
MODULES:0 MODULE SPEC M CILPEAK DUO BLK•G5 31S
PITCH:23'
ORIENTATION:22' UTILITY COMPANY: EVERSOURCE
ROOF 3 UTILITY ACCT#: 51693028045
MODULES:0 NOTES: UTILITY METER M 893915662
PITCH:23'
ORIENTATION:22' 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEALTYPE: SUNNOVA
ROOF 4 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
MODULES:3 2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION.
PITCH.233.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION.
ORIENTATION:112 4.)AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S)NEC 690.13(E). Rev.NO. Sheet
ROOF 5 S.)ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
MODULES:
23'0 6.)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE ^` '
ORIENTATION:202' p 1 {J V 2
ROOF6 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE 1
MODULES:0 CITY SPEC#
PITCH:23' INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL
ORIENTATION:206' R1 ARRAY SCHEDULE FOR MORE INFORMATION m INSTALLED OUTSIDE(UTILITY ACCESSIBLE) SP TO BE INSTALLED 20 HANWHA 315(Q.PEAK DUO BLK-GS 315)
ROOF7
MODULES:0
PITCH:23' INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SESOOOH-USOOOBNC4
ORIENTATION:26' M INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS.REFER
ROOFS I' ll El I
TO EQUIPMENT SCHEDULE FOR SPECS. ri
MODULES:0 OTHER OBSTRUCTIONS ty
PITCH:22' INDICATES EXISTING ELECTRICAL PANEL LOCATION: INDICATES NEW PRODUCTION METER TO BE INSTALLED
ORIENTATION:292' EP INSIDE P OUTSIDE.
ROOF 9 SOLAR
MODULES:0
PITCH:23' INDICATES NEW INVERTER TO BE
ORIENTATION:202' INDICATES NEW FUSED PV DISCONNECT TO BE INSTALLED OUTSIDE. 2211
a INSTALLED OUTSIDE(UTILITY ACCESSIBLE) A Wall,NlewJerse 07719 www.Tnn'775olarco8m
REFER TO EQUIPMENT SCHEDULE FOR SPECS Y M-
Engineer/License Holder:
ARRAY CIRCUIT WIRING NOTES
11 LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2017 SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS
20-315W MODULES W/1 SOLAR EDGE P320 PER MODULE
2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB 25TRINGSOFIOMODULESINSERIES-380Vmax 8"x8" _____________ _________ __
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO --- ------ JUNCTION - -- ------------------------------1
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT F BOX I
TEMP=-16'C '2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1
I
3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED I
ON ASHRAE HIGHEST MONTH 2%DRY BULB 1
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= 1
33'C I
I
4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN I
TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED I
STATES(PALM SPRINGS,CA IS 44.1'C). FOR LESS THAN 9 I
CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED I
SUNLIT CONDUIT AT LEAST O.5"ABOVE ROOF AND USING I Issued Revisions
THE OUTDOOR DESIGN TEMPERATURE OF 4TC OR LESS I
(ALL OF UNITED STATES) 1
I
5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS I
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I n na"07O7O"941PHAPERWT Tnpam
NEC 690.12(A)THROUGH(D) (
NO. DESCRIPTION DATE
6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title:
SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4)
7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE I FORTE,BRIAN
I
IDENTIFIED WITH THE FOLLOWING OUTER FINISH:
POSITIVE CONDUCTORS=RED I TRINITY ACCT#:2020-02-407021
NEGATIVE CONDUCTORS=BLACK
NEC210.5(C)(2) Project Address:
8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE R10 PV EXISTING NOTE:
WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE 1{b 120/240V NA 240V 10 INTERNAL REVENUE GRADE MONITORING I 104 PINE KNOB DRIVE
2
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT 200 MAIN BREAKER I
SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24'SHALL UTILITY METER 00A BUSBAR CONTAINED WITHIN SOLAR EDGE INVERTER I SOUTH WINDSOR, 06074
CONTAIN 5 20 CURRENT CARYING CONDUCTORS AND SOLAR EDGE PN.RWND 3D 240 MB 41.834264,-72.509856
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN 5
9 CURRENT CARRYING CONDUCTORS. ---
= j Drawing Title:
9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS "3
OTHERWISE NOTED
I
10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON PROPOSED PV SOLAR SYSTEM
ROOFTOP AND SHALL BE LIMITED TO 12'IF USED
OUTDOORS D
INVERTER ltl
11.)OVERCURRENT PROTECTION FOR CONDUCTORS DrawingInformation
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE ___a + I DRAWING DATE: 2/7/2020
LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC
705.31 L
__._ DRAWN BY: 1C
e e > REVISED BY:
12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A o L o UTILITY AND THE OTHER AN INVERTER,PVBACKFEED a =e LS L2 N 1BREAKER(S)SHALLBELOCATEDOPPOSITEFROMUTILITY m m -_J� - - - - - - - - - - - - - --------------- ` 0 0 System Information:
NEC 705.12(B)(2)(3)(b) � I I DC SYSTEM SIZE: 6.3kW
EXISTING MAIN BREAKER LOAD I• ,J AC SYSTEM SIZE: SkW
13.)ALLSOLARSYSTEMLOADCENTERSTOCONTAINONLY I. ��------
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR CENTER
LOADS ---------J TOTAL MODULE COUNT: 20
2p30A BACK FEED BREAKER
MODULES USED: HAN WHA 315
NEC 705.12(B)
MODULE SPEC II: Q.PEAK DUO BLK-GS 335
14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
A NEMA 3R RATING UTILITY COMPANY: EVERSOURCE
UTILITY ACCr p: 51693028045
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER a: 893815662
REQUIRED NDU ORAMPACITY PERSTRIN
DEAL TYPE: SUNNOVA
(NEC 690.8(8)(1)1:(15.00.1.25)1=18.75A
PV MODULE SPECIFICATIONS
AWG 830,DERATED AMPACITY HANWHA 315(Q.PEAK DUO BLK-GS 315) Rev.No. Sheet
AMBIENTTEMP:33'C,TEMP DERATING FACTOR:.96
RACEWAY DEBATING=4 CCC:0.80 Imp 9.41 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
(40'.96)0.80=30.72A Vmp 33.46 TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS
30.72A'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 40.29 A R6 THWN-2 GEC TO EXISTING GROUND ROD p 1 PV 3
TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 9.89 B 3/4"CONDUIT W/2410THWN-2,2410THWN-2,1-810THWN-2GROUND
21.00A'1.25=26.25A
C 3/4"CONDUITW/4-R10THWN-2,1-x10THWN-2GROUND
AWG 810,DERATED AMPACITY INVERTER#1-SESOOOH-USODOBNC4
AMBIENT TEMP:30 C,TEMP DEBATING:1.0
RACEWAY DERATING`-3CCC:N/A DC AC p 3/4"CONDUIT W/4-p10THWN-2,1-K10THWN-2GROUND
40A'1.0.40A Imp 13.5 Pout 50DO E 3/4"CONDUIT W/2410THWN-2,1-R10THWN-2,1-R10THWN-2GROUND
40A'_26.25A,THEREFORE AC WIRE SIZE IS VALID Vmp 380 Imax 21
F M10 PV WIRE(FREE AIR)W/p8 BARE COPPER BOND TO ARRAY
Voc 480 OCPDmin 26.25 SOLAR
CALCULATION FOR PV OVERCURRENT PROTECTION
TOTAL INVERTER CURRENT 2l.WA---- Isc 30 Vnom 240
21.00A•1.25=26.25A
2211 Allenwood Road 877-786-7283
->30A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 www.Trinity-Solar.com
YT.-,-N
t
rl
TrUnp
SOLAR
2211 Allenwood Road 977-796-7283
Wall,New Jersey 07719 www.Trinity-Solar.com
INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
FORTE, BRIAN
104 PINE KNOB DRIVE
SOUTH WINDSOR, CT 06074
41.8342640-72.509856
APPENDIX
CONTENTS
LABELS, STICKERS, AND PLACARDS
EQUIPMENT DATA SHEETS
b + � S
FE-3 21 2020
South '�,�ndscr
Building Deng�ment
NOTES:
1.) REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690
2.) STICKERS,LABLES,AND PLACKARDS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.
•
To be located on all DC junction boxes SOLAR PV SYSTEM EQWPED r - n
and every 10'on DC conduit WITH RAPID SWTDOWN
T t
SOLAR
NEC 690.31(G) •"'"'
NEC 690.56(C)(1)(A)
DC Junction Box • • •
1-4M IN
• -
690.56(C)(3) NEC 690.4(B)
I-AXIMUM VOLTAGE
MAXIMUMCIRCUII CURRENT
ELECTRICAL SHOCK HAZARD MAX RATED OUTPUT CURRENT OF
• •• �� rt...H.
Service Disconnect o rK.`OL•vY..a
690.56(C)(3) NEC 690.13(B) NEC 690.53
Soladeck
SOLAR PV SYSTEM EQUIPPED PHOTOVOLTE
tmlity ELECTRICAL SHOCK HAZARD , , ,
WITH RAPID SHUTDOWN
-- - oo vo.M.C..E LM A
UAL:, us oweor I•E�Io —DC-
NEC690.4(B)
KYIm1. l(lAO SOES Yp R E/fKOISEO
N I.ORAL Y06HKIK �
NEC 690.13(B)
MAXIMUM VOL 1AGE
.....
I
NEC 690.56(C)(1)(A) . . .
MAXIMUM CIRCUIT CURRENT
THE CHARGE CONTROLLER
OR DC TOOC CONVERTER
If System is Backfed Breaker NEC 690.S4 NEC 690.53
NEC 705.12(B)(2)1010 a_y
DC Disconnect
NEC 690.54
Utility Meter
Socket
�•ECTRICAL MIHAZARD
00 No" IOI Io..ws
� aK•DILL uc ro io s w s clelolan
RSlCII•rJl slocx wlz.Ko L r rHe aRK IoenKw
NEC 690.13(B)
rt q.Mlf 4.11Iw IR YD �
NEC 690.54
NEC 690.13(B)
72
1
G
DC Conduit Main Service Panel Solar Meter Socket Photovoltaic Load Center Inverter(s) Enphase Envoy Box
AC Disconnect (To Combine Inverters)
powered by DUO „ -
1
!� ---- -Format 66.3 in x 39.4 in x 1.26 in(including frame) ..r,r•....- --+ ,,,,,,,,,,_,
(1685mm x 1000 mm x 32mm) •'� --r
Weight 41.21bs(18.7kg)
Front Corer 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology
Back Corer Composite film
Frame Black anodized aluminum
Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells
Junction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83in
_ (70-85mm x 50-70mm x 13-21 mm),decentralized,IP67 .•+....."o..r
Cable 4mm=Solar cable;(+)e43.3in(1100mm),(-)Z43.3in0100mm)
Connector Multi-Contact MC4,IP65 and IP68 ...emu..-+T I°"'"
ELECTRICAL CHARACTERISTICS
QIIIIIPEAK DUO 300-320 POWER CLASS 300 305 310 315 320
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC (POWER TOLERANCE+5 W/-OW)
Power at MPP' Pit„ [WI 300 305 310 315 320
SOLAR
MODULE
Short Circuit Current* 1, [A] 9.72 9.78 9.83 9.89 9.94
E Open Circuit Voftage• Vic IV] 39.48 39.75 40.02 40.29 40.56
current at MPP• I,,,,, [A] 9.25 9.31 9.36 9.41 9.47
Voltage at MPP' V"„ IV] 32.43 32.78 33.12 33.46 33.80
The new Q.PEAK DUO BLK-G5 solar module from Q CELLS impresses with Efficiency' n [%) 17.8 a18.1 %18.4 z18.7 z19.0
its outstanding visual appearance and particularly high performance MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOC'
on a small surface thanks to the innovative Q.ANTUM DUO technology. Power at MPP' Pw, (WI 222.3 226.0 229.7 233.5 237.2
Q.ANTUM's world-record-holding cell concept has now been combined Short Circuit Current* OK [Al 7.84 7.88 7.93 7.97 8.02
e Open Circuit Voltage' VK IV) 36.93 37,18 37.43 37.69 37.94
with state-of-the-art circuitry half cells and a six-busbar design, thus Current at MPP• I,,,, IA, 7.28 7.32 7.36 7.41 7.45
achieving outstanding performance under real conditions - both with Voltage at MPP' V., (VI 30.55 30.88 31.20 31.52 31.84
low-intensity solar radiation as well as on hot, clear summer days. I000W/mr.25°C.spectrum AM 1.5G 'Measurement tolerances STC:3%;NOC:5% 800 WRrt',NOCT.spectrum AM I SG typical values,actual values may defer
O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
O.ANTUM TECHNOLOGY:LOW LEVELIZED COST Of ELECTRICITY r_ • ,,,
G
„.. aaru At least 98%of nominal power during first year.
Higher yield per surface area, lower BOS costs, higher power _ " ,b a, � Thereafter max.0.54%degradation per year.
o c • --'--- - - '----'-'---- At least 93.1% f nominal power up to]0 years.
classes, and an efficiency rate of up to 19.3 . -
q a At least 85%of nominal power up to 25 years.
INNOVATIVE ALL-WEATHER TECHNOLOGY All data within measurement tolerances. •
I' • Full warranties in accordance with the warrantyIPA � I
Optimal yields,whatever the weather with excellent low-light terms of the 0 CELLS sales organization ofyour
a respective country. • m rm rA
and temperature behavior. s •
11MADIAetr IwrWI
ENDURING HIGH PERFORMANCE "' ` " " • ' Typical module performance under low irradiance conditions in
a y.,..e.,..ERATURE..,.rd..•.+.,.wwn,w.,� rrAAs
comparison to STC conditions(25°C,1000W/m').
Long-term yield security with Anti LID technology, aCELLS R
,..�COEFFICIENTS•.a,._•.Nn.,
Anti PID Technology', Hot-Spot Protect and Traceable Quality Tra.QTM. TEMP
OP R
Temperature Coefficient of Ill a [%/K) +0.04 Temperature Coefficient of V« (%/K) -0.28 S
EXTREME WEATHER RATING '°"°" Temperature Coefficient of Pry, V [%/K, -0.37 Normal Operating Cell Temperature NOCT [°F] 113:5.4(45 33°C)
High-tech aluminum alloy frame, certified for high snow 2017 PROPERTIES ,. SYSTEMDESIGN
(5400 Pa)and wind loads(4000 Pa) regarding IEC. Maximum System Voltage V0, IV] 1000(IEC)/1000(UL) Safety Class II
Maximum Series fuse Rating (A DC) 20 Fire Rating C(IEC)/TYPE 1(UL)
A RELIABLE INVESTMENT O Design load,push(UU' llhs/Ftz] 75(3600Pa) Permitted module temperature -40°F up to+185°F
Inclusive 12 ear product warrant and 25 ear on continuous duty (-40°c up to+85°C)
Y P Y Y Quality Tested
linear performance guarantee2. Design load,pull(ULY (ms/fl'I 55.6(2666Pal 'see installation manual
t STATE OF THE ART MODULE TECHNOLOGY ao sa, �__/ QUALIFICATIONS t CERTIFICATES PACKAGING INFORMATION
Q.ANTUM DUO combines cutting edge cell separation UL 1703;VDE Quality Tested:CE-compliant; Number of Modules per Pallet 32
IEC 61215(Ed.2):IEC 61730(Ed.l)application class A
and innovative wiringwith Q.ANTUM Technology. Number of Pallets per 53'Trailer 30
gY• APT test conditions according to g
IEC/TS 62804-1:2015, V AD: Number of Pallets per4o'High Cube Container 26
method B(-1500V. 168h) D E is Pallet Dimensions(L x W x H) 69.3in x 45.3in x 46.9in �
See data sheet on rear for further
(1760mm x 1150mm x 1190mm) d
THE IDEAL SOLUTION FOR: information. Pallet Weight 1415lbs(642kg)
NOTE:Installation instructions must be followed.See the installation and operating manual or contact out technical service department for further information on approved installation and use r
Rooftop arrays on of this product. ,
®residential buildings
Ilaerrha Y CELLS America Me.
300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA 1 TEL+1 949 748 59 96 1 EMAIL inquuyaus.q-cells.com I WEB www.q-cells.us
Engineered in Germany OCELLS
Single Phase Inverter
wit HD-Wave Technology for North America
Sinle Phase Inverter SE3000H-US SE380OH-US SE5000H-US SE6000H-US
g /
C SE7600H-US / SE10000H-US / SE11400H-US
with HID-Wave Technology ,,, ,,, ,,,,m
E TO INVE'
for North America 'A, '4�MBER
-'xx4
XOUTPUT
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / Rated AC Dower Owput 300(' 38N(4)240V 5000 6wo@-40V 7600 10w0 11400@240V
3300 @ 208V I 5000 @ 208V 10000 @ 208V `
S E7600 H-U S / S E 10000 H-U S / S E 11400 H-U S Maximum AC Power Output 3000 3".@ 240V 5000 1 6000 @ 240V 7600 10000 11400 @ 240V VA
3300 @ 208V 5000 @ 208V 10000 @ 208V
r12-251 M AC Output Voltage Min-Nom-Max. ✓ ✓ ✓ ✓ ✓ Vac
211-240-',64)
WARRANTY
YEAR AC Output Voltage Min.-Nam-Max. ✓ _ ✓ - - ✓ Vac
183 208 229)
AC Frequency(Nominal) 1 59 3 60 605^ Hz
a' Y )
Maximum Continuous Output 2 16 3?_ 42 47.5 A
t Current @240V
fi-y r Maximum Continuous Output -
24 —)— 485
� •rv",�e, d� - Current @208V
2-h1
"—wo-
UtilityPower factor a-11'.,;ta7lp-D Rr,GEDI Threshold A
Monitoring.Islanding
Protection,Country Configurable
Thresholds
a INPUT -
4 4
• soles' .7 ® 0 solar . Maximum DC Power @240V 4650 5900 7150 9300 11800 1550f 1765C —r W-
�' Maximum DC Power @208V - 5100 7750 ts> .,
Transformer-less.Ungrounded Ye
O O Maximum Input Voltage 480 Vdc
O O Nominal DC Input Voltacle 380 400 Vdc
Maximum Input Current @240V 8.5 j 105 l;5 16.5 20 27 30 S Ad(
Maximum Input Current @208V 9 13 5 27 Ad[
O p O O Max vtput Short Cii(wt Curren! 45 I Adc
- Reverse-polaniv Protection Yes
Ground E3a1t IiOlatron DeteCtiC b001�Sensitivity
Maxnr:um Inverter Effidency 99 991
CEC Weighted Efficiency 99 99 @ 240V
983
Optimized installation with HD-Wave technology Nighttrme Power Consumption 25 @L03V —
pp. )tn..•,pg•vna v=tpny-piF-�;e cr-:tn^Seiakoor-;uptx'`
- r.Y tvJ hr,nr ir5 r.l J
,ynrr%.r -r•r.�rp� ', r.zr^i a*oar i .:.r-•r.t i s taL.rP>.:r•r=:
Specifically designed to work with UL1741 SA certified, for CPUC Rule 21 grid compliance A r-
power optimizers
/ Record-breaking efficiency f Extremely small
f Quick and easy inverter commissioning directly
from a smartphone using the SolarEdge SetApp Built-in module level monitoring
! Fixed voltage inverter for longer strings
/ Outdoor and indoor installation
Integrated arc fault protection and rapid
shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data, ANSI C12.20
690.11 and 690.12 Class 0.5 (0.5%accuracy)
solaredge.com solar
i Power Optimizer
-� For North America
Power Optirnizer P320 / P340 / P370 / P400 / P405 / P505
O
For North America •• or 7296- ' '
moduleor higher
.0 power
P320 / P340 / P370 / P400 / P405 / P505modules) "modules)er '' modules)
modules)
m INPUT _
Rated Input DC Power ,,t, 340 370 ;X 4(r, 505 W
Absolute Maximum Input —^
r2 5 Voltage 60 50 1211 831 Vdc
(Voc at 1owe9 temperature)
YEAR MPPT Operating Range 8-48 8-60 8-80 12.5-705 12.5-83 vdc
``4� 'F t° ^~ i Maximum Short Circuit Current
t "} } (ISO 11 101 14 Adc
s _ Maximum DC Input Current 13 75 1263 17 5 Ack
Maximum Efficiency 99.5 %
Weighted Efficiency 98.8 98,16 j
Over voltage Category II
OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximus,Output Current 15 Adc
Maximum Output Voltage 60 -� 85 vdc
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE
INVERTER OFF)
N Safety Output voltage per vdc
Power Optirnizer 1 x 0 1
STANDARD COMPLIANCE
FCC Pa,t15 Class 8.IEC61C00-6-2 IEC61000-6-3
Safety IEC62109-1(class 11 safety).UL1741
�
INSTALLATION SPECIFICATIONS
Maxlr'rum Allowed System
Voltage
Compatible inverters All SolarEdge Single Phase and Three phase over e;s
129x153x33,5; 129x159x495/ 129x162.59/
Dlmenvons(WxLxH) 129xIS3x275/57x6xtt 5,1,6xt3 51.6.3xt9 51xb4x23 rTtm/I�,
Weight(including cables) 630/14 750/1 7 845/19 1064/23 gi/Ib
Input Connector MC4'
Output Wire Type/Connector Double Insulated:MC4
Output Wire Length 095/3 0 t 2!3 9 m/ft
Input Wire Length 0.16/0-52 ,/it
Operating Temperature Range 40- -85:-40-•185 -C/"F
PV power optimization at the module-level Protection.Rating IP68;NEMA6P
Relative Humidity 0-100 %
Rated STl poWi,of the rr�dule Mo uJF of up to,5%pow Jolere"(e ailoweo
r'EC'017,equues n,ax mpul 101tage be nol i*,ae lhan tir.)V _
/ Specifically designed to work with SolarEdge 1 Fast installation with a single bolt for 9thc tbrx,ectoa types Weise contaa Soia,fd'3e
inverters
/ Next generation maintenance with module- PV System Design Using Single Phase Single phase Three Phase 208V Three Phase 480V
/ Up to 25% more energy level monitoring a SolarEdge Inverter HD-Wave
140.P' _
F4U 8
/ Superior efficiency (99.5%) / Meets NEC requirements for arc fault Power Opbrni2e's) Poo P505 6 8 14
protection (AFCI) and Photovoltaic Rapid Maximum Stung Length a5 zs so
/ Mitigates all types of module mismatch losses, Shutdown System (PVRSS _(Power o t,mizeis)
Y ) 57(k(6"with
from manufacturing tolerance to partial Maximum Power pet$trine SE7600 US SEn400 5250 6000 1,75—
shading / Module-level voltage shutdown for installer US)
Parallel Strings of Different Lengths ye,
and firefighter safety or Orientations
/ Flexible system design for maximum space fox deia leO nnrg s,2inp inlcAmahD•,ele,tc nnp nwwwf"larenye ti :,te,defa,Ivfiier „r�-sizir g_na elf
It is not allowed to ma P405/P505 with P3C01P340!P370/1400 in one stung
utilization A Rang with more than.30 optic,-nze,s doe,_not meet NEC tapd shut;trnvn rrquir r_ nls.safety,olt4ge w,ll be above ttw 3W reauu 1 ern
IN SE 14 4KUSnE43 2KUS Iris allowed iu,h"l up to 6 5"pe,5b-n,when S!"1191 are i.-Welled tt'the inverte,f 3 AnngS pe.r unit for 5E41.,KLIS)and
u,e mar,mum power dBererKe Uetv�-er,the anngs s up tc tOUpW
'fa>F 30KU5/SE 33 3KUShE(6 gKUS,'SE tOpKUS It is alKTwed to,n4 all up to tS.IXgw per Qn,l when 3 strings are.Gnnected t.the,nvetter;°,aiinys pe,unit in,SE655KU5i910OfCUS)
and when the norimum pc,wet difference between the srnngs r,up to 2"W
so I a redge.eom solar=@9 C solarEdge Technologi s Ltd All nghn reserved SOLAPEDGE the SourFA*logo.OPTIMIZED By SOLAREDGE are tradenufts a registered 1,ademiim SolarEdge Te hndog es.Inc C
AIf other trademark,me 1—d herein Me t+ade,rwks of thl l respittiv 4wrierl Date 12/2018NOVENG NAM SubjM to change without,brace C RO H S
PAGE 51
G R EAVES
Grounding Connectors
POWER DISTRIBUTION TYPE: LI Lay-In Connector
CU9AL CMC* LI-S ground connectors are manufactured from high strength 6061-T6
BUG•BITES M 90`C aluminum alloy to insure both maximum strength and conductivity. They are
U� sP dual rated for both copper and aluminum conductors and are electro tin plated
Insulation Piercing Connectors to provide low contact resistance and protection against corrosion. They are
Eliminates need for conductor insulation stripping LISTED designed for use on conduit grounding bushings. The open-faced design allows
No taping required after installation the installer to quickly lay-in the grounding conductor as a jumper to multiple
For copper to copper, copper to aluminum, or aluminum to aluminum applications conduits with no break in the ground conductor.
For use on insulated conductor only
90°C RATING (4868 LISTED)
IPC SERIES ji
NAED CATALOG WIRE RANGE TORQUE CTN EST.SHIPPING _
NUMBER NUMBER MAIN TAP VOLTS BOLTS FT-LBS OTY WEIGHT(lbs) UNIT ��� Cond.
Range Dimensions,Inches _
13110 IPC 1002 1/0-8 2-8 300 1 16 12 2.63 CTN Number Fig. No. AWG Stud Sire _H W L
13107 'IPC 4006 4/0-4 6-14 600 1 13 12 1.90 CTN
13108 'IPC 4020 4/0-2 2/0-6 600 1 25 12 4.08 CTN LI 505 1 4- 14 0.22 0.78 0.38 1.07
13109 'IPC 2540 250-1 4/0-6 600 1 30 6 4.17 CTN _ LI-112S 1 1/0- 14 0.27 1.17 1 0.6 1.5
13113 IPC 3540 350-4/0 4/0-10 300 1 25 6 4.17 CTN
13114 IPC 3535 350-4/0 350-4/0 300 2 25 6 7.63 CTN --
13116 tIPC 5012 500-250 10-12 300 1 25 4 2.85 CTN LI-200S 2 1 3/0-6 0.33 1.56 0.8 2
13104 'IPC 5025 500-250 250-4 600 1 55 4 4.06 CTN
13105 'IPC 5050 500-300 500-250 600 1 75 1 2.64 EA CAUTION L LI-252S 2 250-6 0.33 1.79 0.8 2.2
13106 'IPC 7550 750-500 500-350 600 1 75 1 2.62 EA Use Bug-Bites on
'600 Volts,balance 300 Volts(for 480V grounded Y systems) insulated Cable Only! C00494353
t Not CSA certified Do not install on bare cable.
1/4.28 UNF-26 X.53 DP REF.
Q ¢.220 THFtI Q TAP WITHIN.077'MAX Of
Dual-Rated �r NoT DRILL
L ASTWIAY.DO
AY
_ NOT INZtLL PAST WfPEWAY.
GUTTER TAP CONNECTORS �� SP soov CU9AL
I
_ .375 f.010
High strength aluminum alloy 6061-T6, tin-plated LISTED r, i ll�llll Ili .37S* 10
SI
Lay-in designed main conductor remains continuous
Tap parallel or perpendicular to main m CIF
187 t.010
% _ `d.75?<.251
GP SERIES .200 f.015 .190 t.010
m j (s.08 f.718) (4.83 t.2s)
NAED CATALOG CONDUCTOR RANGE APPROX.DIMENSIONS(IN) CTN EST.SHIPPING ////// �-L/•i-28 X.625 LG.S7AlNLE55
NUMBER NUMBER MAIN TAP H W L OTY WEIGHT(lbs) UNIT /// / STEELS .625 SCREW
13117 GP 2' 2-12 4-12 SOL 7/8 5/8 1"/_ 24 1.43 CTN --1.070 1.015--- 000201027(t RW'D)
13118 GP 10 110-2 1/0-12 SOL 1 3/4 11/. 12 1.19 CTN ® (27.18 t.381 ASSEMBLE SCREW SNUG
13119 GP 250 250-1/0 250-6 1'/, 1 V•« 2`/� 12 2.54 CTN TO BOTTOM
13121 GP 350 350-4/0 350-6 1'I,E 1'/. 2'/„ 6 2.75 CTN For copper-to-copper,
13122 GP 500 500-350 5W-2 1`h 1'b 3/A 6 3.10 CTN
13123 GP 750 750-500 500-2 2 1'l.• 3'/� 3 2.5 CTN copper-to-aluminum, _
aluminum-to-aluminum I) II
'GP2 has slotted screws. II
Oxide-inhibitor is recommended for added corrosion protection. soot/9oolir-�
MARKING 2---�� II -AIARKING,I
.7&*,010 Ct4C 4-t4
Snap-on insulating covers for use with GP connectors For indoor use only \ 1501 ON (19.%*.251 u-SO-S CU9AL
GPC SERIES _ 0.81l.15)
MARKING 1
NAED CATALOG FOR USE WITH APPROX.DIMENSIONS(IN) CTN EST.SHIPPING
NUMBER NUMBER CONNECTOR COLOR H W L OTY WEIGHT(lbs) UNIT \\�\\� LBO
- -
13137 GPC 2 GP2 YELLOW 17h. 1}9/. 1'/, 12 0.46 CTN �r7//rr \\\\\�\� \�\\\ ((4.57)) 470 \ .�
13138 GPC 10 GP1/0 GRAY 1'/. 2'h: 7/, 6 0.36 CTN 7ji� 7�tri \1\\\ \\�\\i1\ �;1t.94)/ 0351.005 000210025-/
13140 GPC 250 GP250 RED 11/+ 271. 31/1« 6 0.40 CTN //rrrr�7�r71�n\\\\\\�\\\\ (0.64 t.13) FINM:TIN ft&7E CMS-02
13141 GPC 350 GP350 YELLOW 1'/. 3'/„ 31/. 3 0.42 CTN L 1°,
13142 GPC 500 GP500 BLUE 2'1,; 3'/.« 4'/. 3 0.46 CTN 11/17/2009 LAY IN LUG LI-SO-S
13134 GPC 750 GP750 ORANGE 2'Y, 3'/.a 41h 3 0.65 CTN r.as 9WP0 NAMAL 000601011 $era
Man V7 1 d 1 6061-T6 ALUMINUM 2.25X
www.greaves-usa.com bmaw W CROSS REFERENCE i- QQ
11 Heritage Park,Clinton,CT 06413-Phone 860-6644505•Fax 860-6644546
TOLL FREE 1-800-243-1130(Outside CT)
i
' , • ` SOLARMOUNT memo U N I RAC
■■■
1
� � � I I I 1 1 1 • � I � , 1 1 1 1 • 1 .. BETTER DESIGNS
i • • 1 1 ' 1 1 • 1 1 1 1 1 TRUST THE INDUSTRY'S BEST DESIGN TOOL CONCEALED UNIVERSAL
Start the design process for every project in our U-Builder on-line design tool. ENDCLAMPS
It's a great way to save time and money.
BETTER SYSTEMS 0
ONE SYSTEM-MANY APPLICATIONS
Quickly set modules flush to the roof on sleep pitched roofs. Orient a large variety
of modules in Portrait or Landscape.Till the system up on flat or low slow roofs. END CAPS INCLUDED
Components available in mill.clear.and dark finishes to optimize your design financials WITH EVERY ENDCLAMP
---„ and aestheticsst
BETTER RESULTS
CONCEALED MAXIMIZE PROFITABILITY ON EVERY JOB
UNIVERSAL trust Unirac to help you minimize both system and labor costs from the time the job is
CLAMPS
quoted to the time your teams get oft the roof.Faster installs.less Waste.More Profits.
UNIVERSAL SELF
:I uviRAc BETTER SUPPnRT STANDING MIDCLAMPS
25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM
Professional support for professional insle j;is and designers. You have acccr� to _
our technical support and training groups.Whatever your support needs. we've got
YERR
1 1 • 1 you covered.Visit Unirac.com/solarmount for more information.1\ I
OPTIONAL
fRONTTRIM
U-BUILDER ONLINE DESIGN
1' 1 TOOL SAVES TIME & MONEY
o BONDING&GROUNDING / d sign.unirac.c lu
M
w
y MECHANICAL LOADING
SYSTEM FIRE CLASSIFICATION
UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT
W
21
1 ( 1 1 UNMATCNEO CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT
1 1 'I I 1 1 i 1 I. I 11 i 11 • 1 I I 1 .1 EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION
it 1 1 1
------------
TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY
Unirac s technical support team is dedicated to answering Unirac IS the only PV mounting vendor with ISO certifications Dont leave your project to chance.Unirac has the financial
questions & addressing issues in real time. An online for 90012008, 14001:2004 and OHSAS 180012007. strength to back our products and reduce your risk. Have
THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING library of documents including engineering reports, which means we deliver the highest standards for fit. peace of mind knowing you are providing products of
stamped letters and technical data sheets greatly form, and function These certifications demonstrate our exceptional quality.SOLARMOUNT is covered by a 25 YiI
simplifies your permitting and project planning process. excellence and commitment to first class business practices. limited product warranty and a 5 year limited finish warranty.
111111111111111111111I III11111111111111IIII II IIIIIIIIIIIIIIIIIIIIIIIIIII Illlllllllllllli II II IIII II IIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII lull lllllllllllllllllllllllllllllllllllillllllllllllllllllll lllllllll IIII llllllllllllllllllllllllllllllllllllllll lull ll lull•.Illllllllllllllllllllllllllllllllllll llllllllllllllllllllllllllll ll l li II IIIIIIIIIIIIIIIIIIIIIII
BEST INSTALLATION EXPERIENCE• CURB APPEAL*COMPLETE SOLUTION • UNIRAC SUPPORT ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN
FLASHKIT PRO FLASHKIT PRO
mom one U N I RAC
memo U N I RAC ���
FEATURING O SHED s SEAL TECHNOLOGY INSTALLATION GUIDE FEATURING O SHED s SEAL TECHNOLOGY
FLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring Unirac's patented FLASHKIT PRO IS THE COMPLETE FLASHING AND ATTACHMENT SOLUTION FOR COMPOSITION ROOFS.
SHED & SEAL technology, a weather proof system which provides the ultimate protection against roof leaks.
Kitted in 10 packs for maximum convenience, flashings and hardware are available in Mill or Dark finishes. STEP 2 STEP
With FLASHKIT pro, you have everything you need for a quick, professional installation.
-UUNIRAC
25
INSTALL FLASHKIT PRO FLASHING INSTALL L-FOOT ATTACH L-FOOTTO RAIL
YEAR
PRE-INSTALL Drive the lag bolt down until the L-foot is held firmly in place. It is
WARRANlY normal for the EPDM on the underside of the stainless steel backed
Locate roof rafters and snap chalk lines to mark the installation EPDM washer to compress and expand beyond the outside edge of
point for each roof attachment. the steel washer when the proper torque is applied.
Drill a 7/32"pilot hole at each roof attachment. Fill each pilot hole TIP:
with sealant.
•Use caution to avoid over-torqueing the lag bolt if using an impact driver.
STEP 1 INSTALL FLASHKIT PRO FLASHING Repeat Steps 1 and 2 at each roof attachment point.
•Add a U-shaped bead of roof sealant to the underside of the flashing STEP 3 ATTACH L FOOT TO RAIL
with the open side of the U pointing down the roof slope. Slide
the aluminum flashing underneath the row of shingles directly up Insert the included 3/8'-16 T-bolts into the lower slot on the Rail
slope from the pilot hole as shown.Align the indicator marks on the (sold separately).spacing the bolts to match the spacing between
lower end of the flashing with the chalk lines on the roof to center the roof attachments.
the raised hole in the flashing over the pilot hole in the roof.When
installed correctly.the flashing will extend under the two courses of •Position the Rail against the L-Foot and insert the threaded end of
shingles above the pilot hole. the T-Bolt through the continuous slot in the L-Foot.Apply anti-seize
to bolt threads to prevent galling of the T-boll and included 3/8'*
serrated flange nut. Place the 3/8'* flange nut on the T-bolt and
STEP 2 INSTALL L-FOOT finger tighten.Repeat STEP 3 until all L-Feet are secured to the Rail
with a T-bolt.Adjust the level and height of the Rail and torque each
•Fasten L-toot and Flashing into place by passing the included lag bolt to 30ft lbs.
bolt and pre installed stainless steel-backed EPDM washer through
TRUSTED WATER SEAL FLASHINGS YOUR COMPLETE SOLUTION CONVENIENT 10 PACKS the L-foot EPDM grommet.and the raised hole in the flashing. into
the pilot hole in the roof rafter.
FEATURING O SHED Fs SEAL TECHNOLOGY Flashings,lags,continuous slot L-feet and hardware Packaged for speed and ease of handling
PERMITS/INSP PAYMENT RECPT# 20910155
TOWN OF SOUTH WINDSOR
1540 SULLIVAN AVENUE
SOUTH WINDSOR CT 06074
DATE: 02/21/20 TIME: 14 12
CLERK: morganami DEPT:
CUSTOMER# 691972
TRINITY SOLAR
PARCEL:
CHG: BLDPRM BUILDING PERMIT 468 00
AMOUNT PAID: 468 00
PAID BY: TRINITY SOLAR
PAYMENT METH: CHECK
30182
REFERENCE: 104 PINE KNO
AMT TENDERED: 468 00
AMT APPLIED: 468 00
CHANGE: 00
Electric # APPLICATION FOR BUILDING PERMIT
:?lumbing# u
HVAC# 109
Bole- ► mb D(• Date: lI�a0a�
Sprinkler# Estimated Cost $ —] Q
FINAL APPROVALS
Permit Fee $
Building _ COMPLETE RED BOXED AREAS Occupancy Fee $
Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $
Affidavit ► SIGN ON REVERSE SIDE
Appr.forCO. Total Fee $ �yy.ov
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant C iio b Y _ _ Location of Work_1()L4 _ A f-)Ln0 �] 1 /- Lot No.
`1\
Applicant's Address �C�e e !' ulo- __ _ __ Tel # ,
Town CN\esm y— Zip O(DL4 to Lic.# 0(o3559-0
Owner &an f-ci ' -e, Architect_
Owner's Address UOb Architect's Address
Zip _ Zip
Sq. Ft. New Area: 1 st FI. 2nd FI.`_ 3rd FI. Total New Area
Purpose of this permit AOSAOMOLk10YN �T '4Z) 'COOk ` rY �M A Sp`Qw ,7� G WIS f
V13 It_LA-)
City Water J Well J Septic System J Sewer '_]
Ins: HO SP Cert. n Area Basement Garage
Approved b�� Date Use Group ,J Construction Type
10170o JOq Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this buildi g d its use is allowed.
Signed
I hereby apply for a Certificate of Occu an for the work de cribe in this application for the permit.
Signed
DO NOT WRITE BELOW THIS L NE
INSPECTION COMMENTS
INSPECTION FIELD SHEET 04/19/22
Printed by Middleton, Morgan 11 51 13
INSPECTION: 127065 FINAL PERMIT:
STATUS
APPLICATION: 202000304
LOC: 104 PINE KNOB DRIVE
SOUTH WINDSOR
PROPERTY ID: 72000104
OWNER: FORTE BRIAN L &
CONTRACTOR:
REQUEST BY:
PROJ DESC: INSTALLATION OF 20 ROOF MOUNTED SOLAR PANELS (6 3 KW)
WORK ORDER:
INSPECTOR: WEAR RESULT: PASS
REQUESTED: PRIORITY:
SCHEDULED: 05/04/20 PM COMPLETED: 05/05/20
UNPAID FEES 00 Date Time
MILEAGE: 00 TIME: TRAVEL ONSITE
COMMENTS:
ALL INSPECTIONS:
INSPECTED INSPECTOR RESULT INSP DESCRIPTION
05/05/20 WEAR PASS E010 ELECTRIC FINAL
2000077 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 03/02/2020
GIS ID: 72000104 FEE: 144.00
MUNIS APPLICATION# 202000304 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: TRINITY SOLAR ADDRESS: 104 PINE KNOB DRIVE
ADDRESS: 7 MCKEE PLACE OWNER: FORTE BRIAN L&
104 PINE KNOB DRIVE
CHESHIRE,CT 06410
DESCRIPTION OF WORK: INSTALLATION OF 20 ROOF MOUNTED SOLAR PANELS(6.3 KW)
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
3/2/2020 3:39 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1400167 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER ELECTRICAL PERMIT
DATE: 05/27/2014
GIS ID: 72000104 r FEE: 30.00
MUN1S APPLICATION# 201400608 BUILDING DESCRIPTION:
APPLICAN r LOCATION
NAME: M-W ELECTRIC,INC ADDRESS: 104 PINE KNOB DRIVE
ADDRESS: PO BOX 145 OWNER: GIRARDIN NORMAND R& LUVERA M
VERNON ROCKVILLE,CT 06066 104 PINE KNOB DRIVE
SOUTI- WINDSOR,CT 06074
DESCRIPTION OF WORK: SERVICE UPGRADE't O 200 AMPS{
,ram
SPECIAL CONDITIONS: "
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
40� IV
CONSTRUCTION TYPE:
OCCUPANCY GROUP: Y BUILDING OFFICIAL
5/27/2014 3:30 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
2000059 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER ELECTRICAL PERMIT
DATE: 03/02/2020
GIS ID: 72000104 FEE: 324.00
MUNIS APPLICATION# 202000304 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: TRINITY SOLAR ADDRESS: 104 PINE KNOB DRIVE
ADDRESS: 7 MCKEE PLACE OWNER: FORTE BRIAN L&
104 PINE KNOB DRIVE
CHESHIRE,CT 06410
DESCRIPTION OF WORK: INSTALLATION OF 20 ROOF MOUNTED SOLAR PANELS(6.3 KW)
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
3/2/2020 3:39 PM TIIE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE