Loading...
HomeMy WebLinkAbout104 BENEDICT DR DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT — APPROYED,t 1540 SULLIVAN AVENUE Bldg.Permit# N 644-2511 ext. 230 Nate Building In or Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANTQ�(�\ APPLICANT ADDRESS APPLICANT PHONE# `n OWN Sf,q OWNER �Dt3 OWNER ADDRESS OWNER PHONE C ESTIMATED COST$ 77, 9 COO IS THIS A CONTRACT COST? teooYes _No FEE ENCLOSED$ �� TYPE OF JOBC91� OR-CO New Installation Alteration/Addition/Repair n/_C) APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 0 HEATING PRESIDENTIAL O-A/C ❑COMMERCIAL 0 VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) -F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE '� SS°F DIFFERENCE OF TOTAL HEAT GAIN(BTUH)f q_VIMEAT GAIN SHEET MUST ACCOMPANY AP LICATION) DESCRIBE ALL COOLING E UIPMENT(INCLUDING MAKE&MODEL NO.) C ems-- cJ \ -�S �! C'�f� FN Q L I ,3M ftaPo TONNAGE COOLING CAPACITY(BTUH) OOv VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK 7;Z-- NZ-77 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT rDATE \ 0-1 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: (t/.3 BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Permit�' # 4�-6 644-2511 ext. 230 a D to Building Inspector Application must be printed or typed FEE SCHEDULE F±TAnt J ocati�of Job- -I P $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT APPLICANT ADDRESS 1 n y5� APPLICANT PHONE# O W N S t OWNER � U(I (Yl �1 OWNER.ADDRESS P C�e-j I-c- t LlCJ / 0A SCE OWNER PHONE ��Ll �1 Q g G! I C = ESTIMATED COST$ L �150 �- x IS THIS A CONTRACT COST? _ es _No �G o f"}4� FEE ENCLOSED$ lJ 1,�5 O�� TYPE OF JOB: R C _=Iteration/Addition/Repair ation Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPK OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION?-❑ YES L3 BUSINESS ,( ❑ASSEMBLY CURRENT USE AND OCCUPANCY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL U FACTORY ENGINEER'S NAME PHONE U STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATIONIWIRING METHOD (V\C L4 �41 SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK.-[s _ C�T 9 �5- CONTRACTORS LICENSE NO. r TYPE STATE SIGNATURE OF APPLICA DATE . Me, "Site.-»dem.' of The 'Avery :" 'q r iagdsa L. t�ri4wold Coto Ratr. 24-57 No rtpc� ;► . � �'';."� .'.;� �•' r r . .. :. - ., '•�=�3`: \ , �t '9 ♦ a, .r - TOOL SyEO 53 O IZ IlL Z — '' y•. ti "104. N z: a6.0 vN • _I • 19448 \ . - , .. .ice� •: \ MDRTGAOE SttRYEZ - _ .:: . RMALD �+:: •sU9A1 C SPORED I hereby certify that thi ma ii r �a..:�u � subata►nt 11 P 101► BSXRD?rCT'DR13D�.. ,__ �. is Correct an . no zoning SOUTH:.-1�1MSOR CONNBCTIG re tioila are been violated. AUGUST• 18;1971 SOXW Ir=3.9!. - •_. t .•Douglas. Prior:' S yor M;: ,�:• . y e MAR ;, ?r :# South Windsor BUILDING DEPARTMENT 'his Certified that this plan and Oj sex'N fieations are true aCtad at ^pies of the proposed building or alterations so be �i:,ther with amendments 5tatetl fn a stye' •�•=d with plan and I PPhestfun ar =g,, to comply with all icnlr,p viln ing and state "s dmt such orders as 5'1411 " `"mod CY the Building Dep rrtmcnt during p:•nd—, i tnis application and final issuance of a bul:d;np 'ermit. -fined ` `,Is plan Is approved subje to the Condition that `Meta and ordinances regulating building shall De .r,mphed w+th ondrtionally APProved These filed with 8uilding Inspecto► ///C bri Date a 7 6C, �N�.�,.�J U.;Ii.�` ',�,j;, IJJ�.I-%1 d,it, Vi a:i�il,�_.• shown on tn:s plan a r t .;nformarce with t�p__;.� r to oe i h Wind ,'gulations. Variances Uandlspe6alit except u;, ,ay ap lyff U� 13`•� 2 7.i~nin Fnforr 'l1?f ri Of"^er Lox Numbers refer to map entitled "Site Engineering Plan S* _ 1_ Ave -Hei to South Windsor, Conn. Proppert of The Avery He i is Co. �Ck1e 1 -50� July �, Zyj6,. Hayden L. tirisNold C.E. Rev.1-24-57 Morton S* C =,* t it�. { y. i`ri►a ;i' q5 says.� . t'�` 4 ► �D X 12 Q �n -t"; 'IJ �1t�tl"i� Tov� syEo 53 - 0 0IL r ■1 + t Z Q I tTkWF : •104 M 4o' Jo4 IV sv,- e�, T L7 Q 1 YE i q 0 ..Yn.- •��lS���`j T Yr. IMpRTG AGE SURV EY ROKALD,$. & SUSAN C: 9PONHEI1 R I hereby oertifj that the Map is 104 WEDIOT DRIVE substantial) corroct andrno zoning SOUTH wI]iDSOR CONNECTTCUT re ti ons have been violated. AUGUST 18,1971 SCALE -1"-3 Of DougUa Prior, Su# yor D 211990 South Windsor BUILDING DEPARTMENT 'hF4 6trt►ri:•G that thIS P1 1n ,Plea a4 the p(Opflled hwld+ �reese0 at together with amendments stst¢d in Witltll� ,iced with plan and I agree to compN iuilding and state laws and such orders ds ment ,,j thi by he l Bing nd final issuanceu of rap huu of this application permit. beg This plan is approved qsubjeco the condition i orders and ordinances regulating building shad r complied with. �ptRQ1tNIN)1rC Av7row" These tiled wHh CINr roposed bu;idingis), usets) andjor stru:,�... S � as shown oil this plan appc I") to l or x c z' conformance w;th current South W regulations. Variances and special exec; may apply. Date n ��'`c 2Z iy9a _ Wing Enforcement Officer. Electric # /Fy 3/ APPLICATION FOR BUILDING PERMIT Plumbing# 104 Benedict Drive Date: 7 -go — D HVAC # Sprinkler# R 2 9 8 3 0 -- -- Estimated Cost '$-2 2 0 0�•D D FINAL _ _ __ _ Buildin�/ 09 VF0100' SCIGNN PLETE RED BOXED AREAS Permit Fee $ �3m En nee Occupancy Fee $ /e TYPE OR PRINT ONLY I Eng. Insp. Fee $ Affidavit for CO. ON REVERSE SIDE / � pp Total Fee $ (� . TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant tPONAG O E 'Location of Work�O¢ BEN�Gti'CZ'Der', S, W/NDSD-ot No. Applicant's Address 104 9,CNZ"D11:577 "IiIS Tel.# (9do) ",0—26'P 7 Town .S'DUTW W/NDSDX Zip Ofi O 7¢ Lic.# Owner Architect Owner's Address Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 2nd A. 3rd FI. Total New Area Purpose of this permit I/V5',r4LLi97/0N OF SPA— 147,4^1 y,Z4AICAI!�— MARS City Water❑ Well❑ Septic System❑ Sewer❑ Ins: HO SP Cert. Area Basement Garage Approved by Date - Use Group-- Construction Type Revised 6/02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its u is allowed. Signed I hereby apply for a Certificate of Occ pency for the work described in this application for the permit. Signe DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- *-29830-B 2,000 E02 UNDERGROUND 08/11/03 CJD A NEEDS CONVENIENCE GFI OUTLET NOT LESS THAN 5' NOT > THAN 10' FROM SPA. NEC 680-40 B10 FINAL 09/16/03 JFF A WITH OWNER OUTLET CORNER OF HOUSE B10 FINAL 09/16/03 JFF A CLOSEOUT ••-18431-E 550 r Central A/C HVAC Load Calculations for Ron Sponheimer 104 Benedict Dr. South Windsor, CT. 06074 Prepared By. John Przybylski Hipoint Heating&Cooling,Inc. 71 Edwin Road South Windsor,CT. 06074 (860)291-0181 Thursday,October 25,2007 Rhvac•Residential&Light Commercial HVAC Loads Elite Software Development,Inc. ',ipoint Heating&Cooling Central A/C South Windsor,CT 06074 Page 2 i Project Report Feneralf t Information Project Title: Central A/C Designed By: John Przybylski Project Date: Thursday, October 25, 2007 Client Name: Ron Sponheimer Client Address: 104 Benedict Dr. Client City: South Windsor, CT. 06074 Client Phone: 860-644-2897 Company Name: Hipoint Heating & Cooling, Inc. Company Representative: John Przybylski Company Address: 71 Edwin Road Company City: South Windsor, CT. 06074 Company Phone: (860) 291-0181 Company Fax: (860) 291-0020 Company E-Mail Address: Ipugrab@hipointcooling.com Company Comment: Design Data Reference City: Windsor Locks, Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees Elevation: 169 ft. Altitude Factor: 0.994 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 4 0 50 72 53 Summer: 88 72 50 75 28 Check Figures Total Building Supply CFM: 837 CFM Per Square ft.: 0.747 Square ft. of Room Area: 1,120 Square ft. Per Ton: 566 Volume(W)of Cond. Space: 8,960 Air Turnover Rate(per hour): 5.6 Building Loads - - - - - — Total Heating Required With Outside Air: 37,441 Btuh 37.441 MBH Total Sensible Gain: 18,298 Btuh 94 % Total Latent Gain: 1,127 Btuh 6 % Total Cooling Required With Outside Air: 19,425 Btuh 1.62 Tons (Based On Sensible + Latent) 1.98 Tons (Based On 77% Sensible Capacity) Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. F':point Heating 8 Cooling Central A/C South Windsor,CT 06074 _ Oage 3 i Load Preview Report Sens Lat Net Sens Wm Sum Sys Duct Area Gain Gain Gain Loss CFM CFM CFM Size uildmg: 1.62 Net Tons 1.98 Recommended Tons, 566 fk2ffon, 37.44 MBH Heating Building 1,120 18,298 1,127 19,425 37,441 489 837 837 System 1: 1.62 Net Tons, 1.98 Recommended Tons, 566 ft.2/Ton, 37.44 MBH Heating System 1 1,120 18,298 1,127 19,425 37,441 489 837 837 1303 AED Excursion 1,013 1,013 Zone 1 1,120 17,285 1,127 18,412 37,441 489 837 837 1-Ranch Style Home 1,120 17,285 1,127 18,412 37,441 489 837 837 8-6 1900214 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 04/25/2019 GIS ID:09600104 FEE: 522.00 MUNIS APPLICATION# 201900565 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: SOUTHERN NEW ENGLAND WINDOWS LLC ADDRESS: 104 BENEDICT DRIVE ADDRESS: 10 RESERVOIR ROAD OWNER: SPONHEIMER RONALD E+SUSAN C 104 BENEDICT DRIVE SMITHFIELD,RI 02917, DESCRIPTION OF WORK: REPLACE 10 WINDOWS 2 ENTRY DOORS&BAY WINDOW SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY�070113 BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILD G OFFICIAL 4/25/2019 10:32 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE