HomeMy WebLinkAbout102 STRAWBERRY LN DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: ( '6 4 7 3
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230 a�
Date B din Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
FTenant
a`,, � Pt-r$0-$1,000=$15.00 No. Stree Lot No.
Over$1,000=$15.00 per$1,000 v i !p t Y\or any fraction thereof Designation V Apt.No.
APPLICANT_�� � S on -
APPLICANT ADDRESS oQ '7 x) t. t-
e r-n o n
APPLICANT PHONE# 8 -7,*:2 Q 9 G
0W N St OWNER , _ 220 /i ] �v1, /,j %-- 5 �, �. C•
'9� OWNER ADDRESS
/VeW 1 11G +a r► 0 »n .
» OWNER PHONE
C ESTIMATED COST$ D G. O
IS THIS A CONTRACT COST? ?�Yes —No
FEE ENCLOSED$ 7 5
TYPE OF JOB:
O R-C� New Installation
Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? ❑YES O NO
❑RESIDENTIAL
❑BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY
❑EDUCATIONAL
❑INSTITUTIONAL
❑FACTORY ENGINEER'S NAME PHONE
❑STORAGE
❑GARAGE ADDRESS
❑MIXED USE
CITY STATE ZIP
(Other Please specify)
TYPE OF INSTALLATION/WIRING METHOD
SIZE OF SERVICE ,,2 D D A - SIZE OF MAIN CONDUCTORS fez
NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS *:-�o Z9
NUMBER OF PANELS�_ REMOTE DISCONNECT REQUIRED? 'YES
NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS
SEPARATE BEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
' bnV
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
c?, Co rm
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT 0 Z9DATE oC G"3
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby:
BUILDING DEPARTMENT �—�—
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230 a a
Date Idinj Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
v a� \--V 1C U 1� z 'Vw C t
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT ,\
APPLICANT ADDRESS AV b t' U
S , v.� C7\— c1 �A
APPLICANT PHONE# \, A u.-
OWNER k�- � e- (7 c M
��MI N SFq
OWNER ADDRESS 27 _ Cl a,Q-- -: 6:A -
F OWNER PHONE
cc) 51
ESTIMATED COST$
IS THIS A CONTRACT COST? !/GYes No
FEE ENCLOSED$
TYPE OF JOB:
pR.CO��
✓New Installation
_Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR PLUMBING PERMIT (continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED
BUILDING PERmrr APPLICATION? ❑ YES td NO
RESIDENTIAL
BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY
❑EDUCATIONAL
❑INSTITUTIONAL
❑FACTORY ENGINEER'S NAME PHONE
❑STORAGE
❑ GARAGE ADDRESS
❑MIXED USE
CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION Y) SIZE OF MAIN DRAIN
NO.OF TOILETS STYLE NO.URINALS STYLE
NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES
NO.OF CONDUCTORS�_ SIZE r NO.OF STACKS�_ SIZE
AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS
NO.OF OTHER FIXTURES KIND
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES ❑NO
SIZE OF WINDOW 1 IF NONE C.F.M.OF VENTILATOR
SIZE OF DUCTS SEWER Ok SEPTIC TANK
SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER
WATER HEATER: TYPE MANUFACTURER e CA c n •1
DESCRIPTION OF WORK
,c, k r r
V
THE UNDERSIUNED HEREBY APPLIES FOR A PERMI I I P IQ PERFORM P FHE WORK DESCRIBED AND ISTO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT 7.1 `IM t '� DATE
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Appli n-is hereby: �a6�
BUILDING DEPARTMENT
APPROVE 1540 SULLIVAN AVENUE
Bldg.Permit#
Z .d 644-2511 ext. 230 a el(wap
Date Build Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS
/. 414yelr/l p
APPLICANT PHONE#
O 4 N 3 f,q OWNER
OWNER ADDRESS
&07 OWNER PHONE
C ESTIMATED COST$
a,�► IS THIS A CONTRACT COST? _4-_fes _No
FEE ENCLOSED$ I D 5
f��S 0 TYPE OF JOB:
R-C Xew Installation
_Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR HVAC PERNUT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
la-ItUATING U-6SIDENTIAL
ur,xic ❑COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIlvIIT LBS.
❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE HEA G EQUIPMENT CL� DG MAKE w O E e O.)
AZ -
GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
❑OIL-GPM OIL TANK LOCATION:❑INSIDE❑OUTSIDE CAPACITY
❑GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCP44E ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
CD 3(o C&,s-&aAZ&gl1 /d SE�IQ
TONNAGE 3 COOLING CAPACITY(BTUH) OVV
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
3o3aI,a-'�— .S'1
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
I I I 1;�, x&s
V� ski W
Elm
00 04
----------------------
------------------------
111MM I KME71 NO,11 MI.I I MEIN M11
W
MIMI,,----------------
11 N I NO
=10
'I Z,
_x
111 El 1- I.-M.2 Wr,
Project: CRANBERRY Company:
Client Representative:
Address: Address:
CRT. CRT. . .....
Phone: Phone:
Fax: Fax:
Comment
-g ��gg; -gu-m g,-,tp�-,�g
g
U,
...........
I AW R,-,�:-1.,U�1_-
Project Name: CRANBERRY
Reference City: Hartford,Connecticut
Daily Temperature Range: Medium
Latitude: 41 Degrees
Elevation: 19 Feet
Elevation Sensible Adj.Factor. 1.000
Elevation Total Adj.Factor. 1.000
Elevation Heating Adj.Factor. 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb We Bulb Rel.Hum, DEM Bulb Difference
Winter. 7 N/A N/A 72 N/A
Summer. 88 73 50% 75 33
go
Total Building Supply CFM: 1,085 CFM per square foot 0.525
Square feet of room area: 2,068 Square feet per ton: 800.919
RE m
Total heating required with outside air 54,300 Btuh 54.300 MBH
Total sensible gain: 23,858 Btuh 88 %
Total latent gain: 3,351 Btuh 12 %
Total cooling required with outside air: 27,209 Stuh 2267 Tons(based on sensible+latent)
2.582 Torr.(based on 77%sensible capacity)
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
�������
`► _.. . -nia�
wvokc-pes;des+w a ►dVAC Laads prowom, Eine s~4;e r*ve►4xr�e Alff
in
:: .. ?.
„. .
z:, ::..x• <:rk; >.zz�:a.:- <h,�
..
System#1 RADOM Lna�! �4" <` zz% � zxr> z.�x .>z v w r• :zx r zzxa w�h ti�i
Htg Htg Run Run Clg Clg Clg Zone Clg Air
Room Area Sens Nom Duct Duct Sena Lat Nom Adj Adj Sys
No Name SF Btuh CFM Size Vol Btuh Btuh CFM Fact CFM CFM
-Zone 1-
1 Living 324 13,261 172 2-6 504 4,351 721 198 1.00 198 198
2 Kitchen 160 5,290 69 2-6 535 4,616 737 210 1.17 247 210
3 Dining 312 10,728 139 3-6 453 5,870 713 267 1.35 360 267
4 Master 320 6,506 85 1-6 552 2,382 377 108 1.35 146 108
Bedroom
5 Master Bath __ 144 2,393 31 1-4 420 805 75 37 1.16 43 37
Zone 1 Subtotal 1260 38,178 496 18,024 2,623 820 994 820
-Zone 2-
6 Loft 280 5,326 69 1-6 478 2,062 226 94 1.19 112 94
7 Bedroom 224 4,538 59 1-4 698 1,339 226 61 1.00 61 61
8 Bedroom 224 4,435 58 1-5 581 1,741 201 79 1.19 94 79
9 Bath 80 1,823 24 1-4 361 692 75 31 1.16 37 31
10 0 0 0 0-0 0 0 0 0 1.00 0 0
Zone 2 Subtotal 808 16,122 210 5,834 728 265 303 265
System 1 Totals 2068 54,300 706 23,858 3,351 1,085 1,297 1,085
Main Trunk Size: 16A2 in.
v. .,.;: ::.:
I�
. ..:..:......... .::...:....:..:::..:.:
.:..:.....................
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh_
Net Required: 2.267 88%/12% 23,858 3,351 27,209
Recommended: 2.582 77%/23% 23,858 7,126 30,984
RHVAC-Res;der#ia!S L*rt2 CENi nt -Tc al HVAC Dads Pfagram Eiite Soflwaie Devt4apaita-3.inC.f
-sax CRAaiBERRY
. I Papa 4
_..
uct m> ? a r L.n-adr,
Component Area Sen. Lat. Sen. Total
Desertion Quan Loss Gain Gain Gain
3A Window Double Pane Clear Glass Wood Frame 285 10,208 0 91295 9,295
8M Glass Door Double Clear Glass Wood Frame 40 1,433 0 2,768 2,768
11 C Door Metal Polystyrene Core 20 611 0 156 156
12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 2,135 8,328 0 2,131 2,131
16H Ceiling R-38 Insulation 1,276 2,157 0 1,227 1,227
19D Floor Over Basement/Encl Crawl Hardwood+ R-19 304 513 0 0 0
191 Floor Over Basement/Encl Crawl Carpet+R-19 956 1,491 _ 0 0 0
Subtotals for structure: 5,016 24,741 0 15,577 15,577
Active People: 2 0 460 600 1,060
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 1,200 1,200
Lighting: 200 0 0 682 682
Ductwork: 0 9,050 0 3,975 3,975
Infiltration: Winter CFM: 287.0, Summer CFM: 127.6 345 20,509 2,891 1,824 4,715
Ventilation:Winter CFM: 0.0,Summer CFM:0.0 0 0 0 0 0
Sensible Gain Total: 23,858
Temperature Swing Multiplier: X1.00
System Load Totals: 54,300 3,351 23,858 27,209
.•.�.. --zu,..w:::,, ,<a,,, - xx}rz�:, f::;w•.wz ? ::.„3.:.,,,:,,,.:::.,w.:,.::.:,.:..:,..::.,..,,,:.,:h.::.::...::.:r.,izf:
z,"< ??zxt:...,.,..zz,au,,,,,:.:,,:.:..,,., ,xf� ,�za.s.»,,,w:zzz •.•<, •azxxzrxzz •a. , •:.,<�,..x..::,:..,..:<.::.,,.::.
Supply CFM: 1,085 CFM per square foot: 0.525
Square feet of room area: 2,068 Square feet per ton: 800.919
e: ?r,.„ x •,,: •< „
?`z
.
} NOW
.�.•••�-. � ^.�,�kx:•;:z-.. ,z•,�?, �<;xiu:max` xz^:z{zzz�x zxt3xz�.�:zz�•."zv:;z �z"` ,v.�r•;-�,: .�?.. •�?,..:>:?x:;:::zz::«::�::;:::.xz,,;:�-- ,;x^tx ,-�
� ,
Total heating required with outside air: 54,300 Btuh 54.300 MBH
Total sensible gain: 23,858 Btuh 88 %
Total latent gain: 3,351 Btuh 12 %
Total cooling required with outside air: 27,209 Btuh 2.267 Tons(based on sensible + latent)
2.582 Tons(based on 77%sensible capacity)
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
RtI'+IaC -Resic#�s-,tiai 8+igh+�s,rnrr�ciai ri`1AC loads�'zegram EI#e Sa4farsre f.?cw��ment.tnc.
rp yy�, CR{+z,IBERRY
C#ArAw CT 406 30
z ,.„ WE,
,K>z.
,
Component Area Sen. Lat. Sen. Total
Description _ Quan_ Loss Gain Gain Gain
3A Window Double Pane Clear Glass Wood Frame 198 7,092 0 6,638 6,638
8M Glass Door Double Clear Glass Wood Frame 40 1,433 0 2,768 2,768
11 C Door Metal Polystyrene Core 20 611 0 156 156
12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 1,166 4,547 0 1,163 1,163
16H Ceiling R-38 Insulation 468 791 0 451 451
19D Floor Over Basement/Encl Crawl Hardwood+R-19 304 513 0 0 0
191 Floor Over Basement/Encl Crawl Carpet+R-19 956 1,491 0 0 0
Subtotals for structure: 3,152 16,478 0 11,176 11,176
Active People: 2 0 460 600 1,060
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 1,200 1,200
Lighting: 200 0 0 682 682
Ductwork: 0 6,363 0 3,003 3,003
Infiltration:Winter CFM:214.7,Summer CFM:95.4 258 15,337 2,163 1,363 3,526
Ventilation:Winter CFM:0.0, Summer CFM:0.0 _ _0 n/a nla n/a n/a
Sensible Gain Total: 18,024
Temperature Swing Multiplier: X1.00
Zone Load Totals: 38,178 2,623 18,024 20,647
.}
Supply CFM: 820 CFM per square foot: 0.651
Square feet of room area: 1,260 Square feet per ton: 640.618
Total heating required with outside air: 38,178 Btuh 38.178 MBH
Total sensible gain: 18,024 Btuh 87 %
Total latent gain: 2,623 Btuh 13 %
Total cooling required with outside air: 20,647 Btuh 1.721 Tons(based on sensible+latent)
1.967 Tons(based on 77%sensible capacity)
-: ONSSN:
Component Area Sen. Lat. Sen. Total
Descriptim Quan LOSS Gain Gain Gain
3A Window Double Pane Clear Glass Wood Frame 87 3,116 0 2,657 2,657
12H Wall R-1 9+ 1/2"Gypsum Board(R-0.5) 969 3,781 0 968 968
16H_Ceiling R-38 Insulation 808 1,366 0 776 776
Subtotals for structure: 1,864 8,263 0 4,401 4,401
Active People: 0 0 0 0 0
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 0 0
Lighting: 0 0 0 0 0
Ductwork: 0 2,687 0 972 972
Infiltration:Winter CFM:72.4,Summer CFM:32.2 87 5,172 728 461 1,189
Ventilation:Winter CFM:0.0,Summer CFM:0.0 0 n/a n/a n/a n/a
Sensible Gain Total: 5,834
Temperature Swing Multiplier: X1.00
Zone Load Totals: 16,122 728 5,834 6,562
Supply CFM: 265 CFM per square foot: 0.328
Square feet of room area: 808 Square feet per ton: 1,313.429
::XXXX
-------------- x
• ,M- I0 0�-1- E1
I
M
Total heating required with outside air: 16,122 Btuh 16.122 MBH
Total sensible gain: 5,834 Btuh 89 %
Total latent gain: 728 Btuh 11 %
Total cooling required with outside air: 6,562 Btuh 0.547 Tons(based on sensible+latent)
0.615 Tons(based on 77%sensible capacity)
RHVAC•pc-S f4 161$ ug a comMeTtYa!HVAC Loads Plow am Elite'3CRt.48re C-eVtlQ}nW t, x
G 10
GRAt{Et�RY ..
CAEB 47 :3&4r 36Gt, 3 i:5 c -: Page 3;
y"?.? =:"k???k•`.?'o'.:..a v':'.`;`:',>av'•k `?k.'f.„:?k;::?k'V:`{?`?,?kN:.?Ya.".,a y `;?'^. ":{krt-`.:x:. ?:'. inkkx-,,."-k:`?`YJr..aJ':,`a,•`Y : •••\,k;`ha yx:`,:Y•`Y _ '3:r;i `YY\yi•a,
«h:-�{} z
`�$t' ? 2 a a.•"y.�ziiµ,{ri "z },
;':}.. w. ... ... T ?z` z?,z
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3A Window Double Pane Clear Glass Wood Frame 285 10,208 0 9,295 9,295
8M Glass Door Double Clear Glass Wood Frame 40 1,433 0 2,768 2,768
11 C Door Metal Polystyrene Core 20 611 0 156 156
12H Wall R-19 + 1/2"Gypsum Board(R-0.5) 2,135 8,328 0 2,131 2,131
16H Ceiling R-38 Insulation 1,276 2,157 0 1,227 1,227
19D Floor Over Basement/Encl Crawl Hardwood+ R-19 304 513 0 0 0
191 Floor Over Basement/End Crawl Carpet+R-19 956 1,491 0 0 0
Subtotals for structure: 5,016 24,741 0 15,577 15,577
Active People: 2 0 460 600 1,060
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 1,200 1,200
Lighting: 200 0 0 682 682
Ductwork: 0 9,050 0 3,975 3,975
Infiltration:Winter CFM:287.0, Summer CFM: 127.6 345 20,509 2,891 1,824 4,715
Ventilation:Winter CFM: 0.0,Summer CFM:0.0 0 0 0 0 0
Sensible Gain Total: � - - - - _ _ - _ - -_ 23,858 I
Temperature Swing Multiplier: X1.00
Building Load Totals:_ 54,300 3,351 23,858 27,209
"``a � :`
h, ... .} ak, .•.0 ,;�:zya �Zaa� �zyk,:kY.k•.\. �;y:..?•.
:..th` .-y Y} )> rvv t-i :4:{..v..'- •>. YY}.v ` v�4`• ?SC:?�..2.{:kv;:.�:v....: v'-C.�.v:vy:{.kY•Y"
,�a'�YZYr,�xzn �zk .?<�:•: •k4.�;Y` �� ..x:,,..w,...{ `�``'*.'",� w r?, ,::kzzYYY?-3c`x:: YY ;Y�{.:;^.??r.,'{?;f.,,,,,�i��:wz�t;:..:.?k:;yr.;:-.::.,..ikkkkkza.:'.:::•:::..Total Building Supply CFM: 1,085 CFM per square foot: 0.525
Square feet of room area: 2,068 Square feet per ton: 800.919
- :.:.:•`.�ti:..:.:..$..,..c..a.{.{•1' :.h..{,•:.a,�r:Y:a.`<
} ..:��iy .:. .�--,.-.-� .... .....-s.a:.-y......r... ....... .......�-ua�_. �-::. .........-::.. ..`:Y`•sAyii:�h i:.?<?27jny}+•lb?yZ{NL8j3::Yiv:iy`v`.:5...:
Total heating required with outside air: 54,300 Btuh 54.300 MBH
Total sensible gain: 23,858 Btuh 88 %
Total latent gain: 3,351 Btuh 12 %
Total cooling required with outside air: 27,209 Btuh 2.267 Tons(based on sensible+ latent)
2.582 Tons(based on 77%sensible capacity)
::i ;rr..rh<: `y�nf`•v.`.? •av r•3r; .r.`a? .,�,1 ia. .�.;;`:�'.::'i�r�� ?�"r'!•`X'•`3`'y h }{
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
1540 SULLIVAN AVENUE Bldg.Permit#
MAR 644-2511 ext. 230 -�L (t,-rl
Dat Building In or
Application must be printed or typed
FEE SCHEDULE
Location of Job:
f e
$0-$1,000=$15.00 FTenantDesignation
Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Apt.No.
APPLICANT_IlPi1tL Z;, ,
A024 (A
APPLICANT ADDRESS
��7/,�11c�s'o✓
APPLICANT PHONE# /y
O W N St OWNER -
OWNER ADDRESS
Q �
U) o OWNER PHONE
C I� ESTIMATED COST$ 1411, O 0
IS THIS A CONTRACT COST? Yes _No
e �(✓ FEE ENCLOSED$ �c
10 � - O�� TYPE OF JOB:
12.C New Installation
Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
91RESIDENTIAL BUILDING PERMIT APPLICATION? ❑YES ❑NO
O BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE❑EDUCATIONAL FUTURE USE AND OCCUPANCY
O INSTITUTIONAL
❑FACTORY ENGINEER'S NAME PHONE
O STORAGE
U GARAGE ADDRESS
❑MIXED USE
CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD
SIZE OF SERVICE _e jV SIZE OF MAIN CONDUCTORS
NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS
NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ONO
NUMBER OF LIGHT CIRCUITS_4 NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES -Y, a NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS l
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CO ORS LICENSE NO. TYPE STATE
4�z
SIGNATURE OF APPLICANT DATE
Shirley Wilhelm-CRS Approval Confirmation: Request No.285621 Page 1
From: <clpsvc@nu.com>
To: <WILHEL@SOUTHWINDSOR.ORG>
Date: 3/18/04 12:03PM
Subject: CRS Approval Confirmation: Request No.285621
Your approval of the following CRS Request has been successfully processed.
CRS Work Request M 285621
House No: 101-103 /QaZ
Lot No:
Street Name: STRAWBERRY LN
Town Name: SOUTH WINDSOR,CT
Inspector: CHRISTOPHER DOUGAN
Approval Date: Mar 18,2004
This e-mail, including any files or attachments transmitted with it, is confidential and intended for a specific
purpose and for use only by the individual or entity to whom it is addressed. Any disclosure, copying or
distribution of this e-mail or the taking of any action based on its contents,other than for its intended
purpose, is strictly prohibited. If you have received this e-mail in error, please notify the sender
immediately and delete it from your system. Any views or opinions expressed in this e-mail are not
necessarily those of Northeast Utilities, its subsidiaries and affiliates(NU). E-mail transmission cannot be
guaranteed to be error-free or secure or free from viruses,and NU disclaims all liability for any resulting
damage, errors, or omissions.
...............
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-30360-B 1,000
B04 INSULATION 02/05/04 JFF A WITH CONTRACTOR WALLS ONLY NOT ATTIC OR CELLA
B09 OTHER 02/11/04 PJP A FIRESTOPPING +
H03 ROUGH 02/11/04 PJP A FOOR DUCTS ONLY (V\
E01 SERVICE 03/08/04 CJD A
E01 SERVICE 03/10/04 PJP A
B04 INSULATION 04/05/04 JFF A BASEMENT WITH CONTRACTOR
P03 ROUGH 02/05/04 JFF A BASEMENT GAS FIREPLACE CLEARANCES ONLY NOT
TESTOO
PO4 GAS TEST 04/13/04 JFF A INCLUDING BASEMENT GAS FIREPLACE WITH ED HAVE
NS
B10 FINAL 10/29/04 PJP D NOT READY
**-18792-E 5,000
Total Est Value 6,000
Dwelling 2,091 105,072 75
Basement 1,291 19,365 00
Garage 287 4,305 00
Smoke Det 7 525 00
BOCA Value 129,330 48
Difference 123,330 48 1 -
�\ r
i
lcccriu# I ?7 9a APPLICATION FOR BUILDING PERMIT
Plumbing# �� 102 Strawberry Lane Date: C�j
HVAC # V_
Sprinkler# 30360
FINAL APPROVALS 1 Estimated Cost $ /CVO
-- --_-- -- -_-- -Building COMPLETE RED BOXED AREAS Permit Fee $ 15—
Engineering Occupancy Fee $ !'
g O
TYPE OR PRINT ONLY Eng. Insp. Fee $
Af pdavi
for CO. at SIGN ON REVERSE SIDE 1
- - Total Fee $
TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant Cstc-tia., �, nytocation of Work /t';?, Lane Lot NoU
Applicant's Address ,?e K PGk�f Tel.# 8(,0 is 7S— 929S
Town l/e �n o�� Zip VVIOo66 Lic.#,UftCC 3577
Owner 5«l/.'✓¢-i G LC� Architect .a K cv G,'c�1, tr<c, �✓�s c--�
Owners Address .2(000 1;,p:Ke Architect's Address Pia g,' dd(e&ra-
4 Zip A611 I Zip o6 q
Sq. Ft. New Area: 1 st FI. I2, 5— 2nd FI. g3 1 3rd FI. Total New Area 2 i 16
Purpose of this permit
c'1r' Cgpc,S
Q� �U
City Water Well❑ Septic System❑ Sewen/
Ins: HO SP Cert. Area c20 9 / Basement 2- cj Garage 7
Approved by Date Use Group Construction Type
Rsvissd GM2
s '
1 hereby agree to confer n to al the requwerner#s of fine Laws of>M State of Connecticut and the Ordinances of the Town of
South Windsor and to no"the Inspector of any atteratlon in the plans or apedflafbns of the Building for which this
permit is aWcsd,and ague that du bukkV is to be Iocqts distance from aN street Mnes,side yard lines,and required
dhtanoes from allother zones and is bcated in and use is
Signed
I hereby applyfor a Certificate of descrt in this for the permit.
Signed ,j �,,�� s �c�:y►
tO NOT WRITE W THIS LINE !J
INSPECTION COMMENTS
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
•i-30360-B 1,000
B04 INSULATION 02/OS/04 JFF A WITH CONTRACTOR WALLS ONLY NOT ATTIC OR CELLA
B09 OTHER 02/11/04 PJP A FIRESTOPPING
H03 ROUGH 02/11/04 PJP A FOOR DUCTS ONLY
E01 SERVICE 03/08/04 CJD A
E01 SERVICE 03/10/04 PJP A
B04 INSULATION 04/05/04 JFF A BASEMENT WITH CONTRACTOR
P03 ROUGH 02/05/04 JFF A BASEMENT GAS FIREPLACE CLEARANCES ONLY NOT
TESTOO
PO4 GAS TEST 04/13/04 JFF A INCLUDING BASEMENT GAS FIREPLACE WITH ED HAVE
NS
B10 FINAL 10/29/04 PJP D NOT READY
B10 FINAL 11/0S/04 PJP A CORRECTIONS MADE
+*-18792-E 5,000
Electric# I 4� 4-73 APPLICATION FOR BUILDING PERMIT
Plumbing# t l Li9! 102 Strawberry Lane of
HVAC # I No";OL Date: S /6 0
Sprinkler# No. 29620
FINAL APPROVALS Estimated Cost S —
Building COMPLETE RED BOXED AREAS Permit Fee $
Engineering �i�i TYPE OR PRINT ONLY Occupancy Fee S
Affidavit SIGN ON REVERSE SIDE
Appr.for CO. Total Fee $��27 S
TO BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $
The undersigned hereby applies to do work according to the following specifications: `vl/
Job Location 107- Lot No Jt Side of StreetE"i- Zone J
Applicant6u •w&& -y-'mph 4 Ux. �1''oQ,>AL-q 60tLpeAb-l.tL Tel # "B4o0 Bna•2.00
Address 21aGn fteL4hr tA&&p►KE , IJE�,.h�•1t{tb�.i GT Zip oeptll Lic.# l(54}-
Owner-: ,Auu.jIuJ 1oww V"c,,t 1 I Address uoey ft ,IJ-QgAP1M Ikujoa- l Cx 0&111
Architect L3i.a■• ;,oune y,eS,To#I Address fN ?ewtb I mmue-lywo,aim2= o�� GT of S'7
Sq. Ft.New Area: 1st FI. 17-6G 2nd FI. a31 3rd Fl. N o.L Total New Area 2 11l0
#Rooms #Lavatories #Bathrooms Z #Garages 71
Purpose of this permit: isle.,,] or-,aC-0:1)
City Water W, Well ❑ Septic System ❑ Sewer L�
Ins. H.O. S.P. Cert. Area '24al 1 Basement 12'1( Garage C 7
Approved by ] Date Use Group 0C Construction Type —
Revied 1197
_ i
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from street lines,side yard lines,and required
distances from all other zones and is located in which this buildin and its use all
Signed - F
I hereby apply for a Certificate of Occupancy for the ork dessr in application for the permit
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
r' Inspection / Approval Date By Appl
Code Description Due Whom Code Comment 0
-----9---0-----------------------------------------------------------------------
*+-29620-B 150,500
BO1 FOOTING 06/05/03 JFF A WITH CONTRACTOR RICH REAR HALF ONLY
BO1 FOOTING 06/06/03 CJD A
B02 FOUNDATION 07/30/03 CJD A
P02 UNDERGROUND 12/24/03 JFF A WITH ED HAVENS
P03 ROUGH 12/24/03 JFF A WITH ED HAVENS
B03 FRAMING (ROUGH) 02/02/04 CJD D JOIST HANGERS OBSMT IJOISTS/LAMS, FIREBLKNG
1ST AND 2ND FLOOR CONCLD SPACES
E03 ROUGH 02/02/04 CJD A
P03 ROUGH 02/02/04 CJD A
H03 ROUGH 02/02/04 CJD A
B10 FINAL 02/06/04 CJD N/A CLOSED OUT. COMPLETED UNDER PERMIT 30360
NAEK CONSTRUCTION.
**-11491-P 3,000
**-18473-E 4,200
**-12058-H 7,000
**-18474-E 4,200