Loading...
HomeMy WebLinkAbout101 LONGMEADOW DR 0 APPLICATION FO ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074(PHONE)860-644-2511 EXT. 230 DEPARTMENT DECISION PERMIT NUMBER: APPLICATION IS HEREBY: APPROVED- B N R 7 D TE INSPECTOR LOCATION OF WORK: U I Lyft rne(do.✓ 1), APPLICANT: OWNER: TYPE OF STRUCTURE: ((�� JJ plN1:W suu.DnaG NAME: �JGI V I Q 1�'h y NAME: �U' D n�0��1✓3 �h O ❑ADDMON PHONE NUMBER: 860-667-26 52 PHONE NUMBER $6d - SS0- 3175 0 EXLSnNG BUILDING ADDRESS: 36 No cma- D• ADDRESS: 2ft 14eb c., Air �(ev;ngl of CT o6lit 6lai16,bu►y CT- 06033 TYPE OF USE: )(RESIDENTIAL o COUNMCIAL ELECTRICAL INFORMATION: ' ,I FURTHER DESCRIPTION OF WORK: TYPE OF INSTALLATION: I r m I/r NEW Num e SIZE OF SERVICE: 200 C-MD SIZE OF MAIN SERVICE: �1 C R 5 *V- 3� 750,2 7 NUMBER OF METERS: �- NUMBER OF PANELS: y NUMBER OF LIGHT CIRCUITS: ESTIMATED COST:S 7 UV n NUMBER OF SWITCHES: NUMBER OF LIGHT FIXTURES: FEE ENCLOSED:S 169. NUMBER OF A/C CIRCUITS: , FEE SCHEDULE:SIS PER$1.000 OF THE ESTIMATED COST. NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS$1.00 OVER (.26 CENT EDUCATIONAL FEE INCLUDED AS NUMBER OF OUTLETS: PART OF THE PERMIT FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING e0D PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: E 5! 6/ T E 1 STATE: C T SIGNATURE OF APPLICANT: DATE: 5 1 9 NOTES OPEN SPACE #1 1. TH 2t IP TO IP TO AE BE SET_ N83'58'54'E 115.00' BE SET ° �PDsr RAIL FED ° - ° 2. TE 119 LF W \�DPE 046 2. 5 -+- YD 39 TF-198.66 3. BC -201.B4 ILn-195.66 -- nn-'In a4 _- \` -- lout-195.61 4. W lout-19&59 N \ 2O' DRAINAGE EASEMENT4 \�0 I �\ do REAR SETBACK \ I 5. BE 1I 10' DRAINAGE EASEMENT 6. M1 tJ, I 14 & SIDE SETBACK 1 • 1�� 00 0 B. 0I 2p4 �-- L� C. (\�`�• CO 40.761 Pl.Y fopDOOR N W izo.95 'u� 1471 3 FP �AC o o I EM EXIM9 ; o D. � o DWEWNG M( 21 19 go P I l FF-207.25 z GF-205 i1 I tea' 14.04' �19.63' 7. PI BIT. 7.82 It DRIVE % 1.89 A. Sx C4 B. COVERED C . CONC. PORCH t / 6=11'07'57' / 8. UI b O R-175.00' Ce t9 IN -- L-34.00' /TF-200.54 F( 3 9444((Iln-193.84(2 6'pv" L� CLdcP EASEML?J _ , Iln=19yd36) _ GV lln-194. cb20 9. TF 17c BE -lin-192.64(eb22 ETC Et' / lout-192.54 10. TF IP 0WV / BE SE�o,,� CONC. wALx tio1 / '� PI 223 LF 15' HDPE 0 4.26 �SMH 6 / 11. D[ 7F-200.68 _Vc 0 3.45% lout-188.73 -V�SMH7 9BLF 8' P VII / Iln-192.34 W G / W W lout-192.24 / G G G GRAPHIC SCALE Know whars below. 30 0 30 60 ® Call before you dig. IN CONNECTICUT CALL 811 (IN FEET) OR 1-800-922.4455 1" = 30 FEET lbs- c& - dQ-�4L If��h�,► o-e J� MO���IiU�p-T �nI S E C014PLLMKZ aECKLIST RECEIVED WM OF SOUM W=DsoI;,ooNgtEC r=T *****FOR C OF O***_* OCT 0 4 2019 SOUTH"NDSOR PLANNING DEPT. MMES5 l0 I ��(�/S^�,) LOT/UMT# C, Reviewed CONTACQT//DEv�l Ar u Date Reviewed i A�i I/Denied Reviewed by (Planning) Date&ft tted j2L 3-1 Dade Revte,Med 9 p�e Date Reviewed Approved/Denied(Wealth) As required in the Zoning and/or Subdivision Regulations,no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved budding permit plan J 2. Finish grading per approved budding permit plan ✓ 3. Site woriq i.e.trees,shrubs, dumpsters,required parldng 4. Utility location; —�� a. sanitary sewer/septic systems b. foundation drain C. electrical &telephone ✓ d. water —�_ e. cow GA s — 5. Sewer connection charge paid —�_ 6. Appropriate certification 7. Bonding 8. Planning&Zoning/ Inland Wetlands Considerations a. Lighting b. Signage Freestanding Wall C. Fee in lieu of Open Space COMMENTS: 2 c v-,*tl .4s 1—s Set W%VineerirWmo1oy/sibs oort>piarce c vdAst NOTES: OPEN SPACE #1 1. THE SURVEY HAS BEEN PREPARED PURSUANT TO THE REGULATIONS OF CONNECTICUT STATE AGENCIES SECTION 20-300b-1 THROUGH 2O-300b-20 AND THE "STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" IP TO IP TO AS ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. ON SEPTEMBER 26, 1996. BE SET N83'58'54"E 115.00' BE SET o n P- N�E n o n 2. THE TYPE OF SURVEY PERFORMED AND THE MAPPED FEATURES DEPICTED HEREON ARE IN ACCORDANCE WITH THE REQU REMENTS OF A ZONING LOCATION SURVEY. 119 LF 12•�DPE O 2.46% _ \\ TF 38 �rD 39 TF=196.6s 3. BOUNDARY DETERMINATION/OPINION IS BASED UPON A DEPENDENT RESURVEY OF MAP REFERENCED IN NOTE 6A. TF=201.84 :out-195 6 ■ lin=lob 64 lout=195.61 4. WITH RESPECT TO THE BOUNDARY. THIS SURVEY CONFORMS TO CLASS A-2. �i lout=198.59 WITH RESPECT TO THE TOPOGRAPHY, THIS SURVEY CONFORMS TO CLASS T-2. I � 20' DRAINAGE EASEMENT \?00 & REAR SETBACK \ I 5. BEARINGS AND NORTH ARROW BASED UPON MAP REFERENCE 6A. \ 10' DRAINAGE EASEMENT 6. MAP REFERENCES: Z � & SIDE SETBACK O -.� A. "ESTATES OF SOUTH WINDSOR, GRAHAM ROAD AND NEVERS ROAD, SOUTH WINDSOR, CONNECTICUT," DATED a0 -10 I FEBRUARY 8, 2017, REVISED THROUGH AUGUST 3, 2017 PREPARED BY MILONE & MACBROOM; ON FILE IN THE V 20 �� K SOUTH WINDSOR LAND RECORDS AS MAPS 14171-4176. " o CJ B. "PROPERTY SURVEY, TOLL BROTHER, GRAHAM AND NEVERS ROADS, SOUTH WINDSOR, CONNECTICUT..- SCALE W 0 ui 1"=100' DATE 11/12/16 REVISED 01/19/17 PREPARED BY DESIGN PROFESSIONALS. p 204 - r'- BILCO = C. "COMPILATION MAP, MAP SHOWING EASEMENT AREA TO BE GRANTED TO THE CONNECTICUT LIGHT AND POWER W 40.76' U�zyo�L� DooR N ;� COMPANY, d.b.a. EVERSOURCE ENERGY, ACROSS THE PROPERTY OF TOLL LAND XVIII, LLC, GRAHAM & NEVERS �,zo.ss, LA'A5� /1z71� , o ROAD, SOUTH WINDSOR, CT." SCALE: 1"=80' DATED 8/22/17 REVISED 8/29/17 PREPARED BY ESE 3 I FP 1 o CONSULTANTS; ON FILE IN THE SOUTH WINDSOR LAND RECORDS IN VOL 2612 PAGE 180. AC 0 o EMI j ` ff E)aS71NG pA , N D. "COMPILATION MAP, MAP SHOWING EASEMENT AREA TO BE GRANTED TO YANKEE GAS SERVICE COMPANY, d.b.a. 9 o i ENSTI NG N 21 EVERSOURCE ENERGY, ACROSS THE PROPERTY OF TOLL LAND XVIII, LLC, GRAHAM & NEVERS ROAD, SOUTH � I in 11 FF-207.25 WINDSOR, CT." SCALE: 1"=80' DATED 8/22/17, PREPARED BY ESE CONSULTANTS; ON FILE IN THE SOUTH WINDSOR 01 �. GF-205.11 M ` LAND RECORDS IN VOL. 2618 PAGE 234. li Z � � I j q'/14.04' 19.63' BIT. 7. PARCEL IS SUBJECT TO: �'7.ez' � DRIVE A. STREET TREE EASEMENT ON FILE IN THE SOUTH WINDSOR LAND RECORDS IN MAPS #4171-4176 & V. 2658 P. 111. a 8 * 1� B. DRAINAGE EASEMENTS IN FAVOR OF THE TOWN OF SOUTH WINDSOR ON FILE IN THE SOUTH WINDSOR LAND RECORD 7a'11 4.69 1 IN V. 2658 P. 125. V. 2676 P. 290 AND MAP #4287. COVECO CRC C. SEWER LINE EASEMENT IN FAVOR OF SOUTH WINDSOR ON FILE IN SOUTH WINDSOR LAND RECORDS IN V. 2658 P. PORCH 120. b i 1 d=-11'07'57" / 8. UNDERGROUND FEATURES TO HAVE BEEN COMPILED, IN PART, FROM INFORMATION PROVIDED BY OTHER OTHERS. THIS ri o R=175.00 CB 19 INFOFMATION IS TO BE CONSIDERED APPROXIMATE IN NATURE AND ESE CONSULTANTS DOES NOT TAKE RESPONSIBILITY _ _o EET--TR EASE _ L=34.00' /TF-200.54 FOR SUBSEQUENT ERRORS OF OMISSIONS. NO FIELD VERIFICATION IS IMPLIED FOR THE LOCATION OF THE SANITARY Iin-193.84(2 6"pvc) LATERAL; WATER, GAS AND ELECTRIC SERVICE LATERALS. CL&P EASEMENT ` lin-193.94(yd38) _ / L . lin-194.44(cb20) 9, THIS PLAN IS NOT VALID WITHOUT THE LIVE SIGNATURE AND EMBOSSED SEAL OF THE LICENSED LAND SURVEYOR. ETC ET C BE lin=192.64(cb22) / lout=192.54 Li.l WV G / v 10. THE ITEMS SO NOTED ON THIS PLAN HAVE BEEN VERIFIED IN THE FIELD AS TO LOCATION, ELEVATION, AND > IP TO CONC. WALK o : COMPLETENESS. THE FOLLOWING ITEMS LISTED ARE THE ONLY DEVIATIONS FOR THE ORIGINAL PLANS APPROVED BY THE BE SE7o, TOT /�� PLANNING & ZONING COMMISSION AND STAFF APPROVED CHANGE ORDERS: W 0 � � Z 223 LF 15• HDPE 0 4.26 _ 3 o' s / 11. DEPICTS CONDITIONS AS OF SEPTEMBER 26, 2019. > �O s - - S TF-200.68 i lin-188.83 ----------===-ems H _=98LF 8• pVC 03.487G t W�lout=18s•73 ZONING DATA - RR ZONE z L FZ lip-isi3a W G / DESCRIPTION REQUIRED PROVIDED AS-BUILT o z o U W wlout-192.24 ~ Z 0 G c G / LOT AREA 20,000 SF 20,470 SF 20,470 SF U _j o LOT COVERAGE 20% MAX. 11.7% 11.7% O Q FRONT YARD 40' 43.52' 43.51 D SIDE YARD 10' 19.58' 19.63' I $ REAR YARD 20' 76.22' 76.28' O O Q MIN. FRONTAGE 75' 115.36' 115.36' F- ~ GRAPHIC SCALE MAX. BLDG. HEIGHT 30' 27.99' 28.1' W Know what's below. 30 0 30 60 MY KNOWLEPGE AND BELIEF THIS MAP IS SUBSTANTIALLY � � o C811 before you dig. S N C jH(EON. IN CONNECTICUT CALL 811 (I N FEET) roe wo �� OR 1-800-922-4455 ' =2Mv 1" = 30 FEET DOUGLAS S: CARS_R. CT P.L.S. #70458 RECEIVED OCT 0 3 2019 SOUTH WINDSOR ENGINEERING DEPT. SM COMtiN.UMM ICHECRLISI' ED Tower OP Own WMD,SW CONNECTICUT *****.st�°I"s ***** JAN 302019 (bIYfACI'/DEY�C�-�L- G D • / f SOIliH VNNOSOR PLANNING DEFT. 1/9 Agffift"M Re t%vd by (�amrgj Date Submitted__P0 Date / 3 p ied. Revhwred by &dth Dept) Date In accordance with the Zmft and/or SubdMsion Reguiatiorns,prior bD the txrAdfrxj of aq sbudum on a tort a Topographic Pbt Plan shah be submitbed for app mi. The minimum requirements shaft kx%de: Approved Denied NIA 1. Name,address&phone rrarrber of / JaOp�� 2. Name,address&phone number of plan preparw 3. za"Lfbrinadon-Le.acne,open space, / t WVQy,She address �.L 4. Plot Plan at 1'_�IQ'scak a, SrbdivWm reflTlOoS,abutting Matie�.err b. Easanarts of record C. LotArscipdr, 4bart4gsr built Ifni, area,etc ✓ d. Cor>murs,,.erdog&proposed,l or 21 G interval whore appropriat ' e. . &dft bcom with dimensions 8evoons of proposed lush floor,garage loot&centerline of road at dr mW - _� f. Gewdors of Woly drab *gtarn!s,salary &figtrtMm driin at the house and the street TenWo utl V iocedn (gas,water,electric, h. Tittle bbdc with im, &address of preparer, date,appropriate certification,five seed&IMe t con.41 t wb the Board of Regisb'atioif requirarjZrft(P.E&LS.) S. ' . Seen UMM and scsb aontrd f5,.. Spam Platting&Iatg,l ft4 Wettands aoraidr�adw(Pf m on&w/Town.Cla* �9�.7• �L� $��- l �' �ri r..- � l,✓k-t mil. F1tt�.�p{� dbdit NOTES: OPEN SPACE 1 I 1. THE SURVEY HAS BEEN PREPARED PURSUANT TO THE REGULATIONS OF CONNECTICUT STATE AGENCIES SECTION 20-300b-1 THROUGH 2O-300b-20 AND THE "STANDARDS FOR SURVEYS l _ N835854"E 115.00� _ _�` ❑ ASSOCIATION OAND MAPS IN FiLAND URVEYORS,STATE OF ENC. ON SEPTEMB RCTICUT" AS D26Y19 6 CONNECTICUT '' ❑ ❑ ❑ ❑ ❑ ❑ / Q € G 119 IF 12• H E o 24sz 2. THE TYPE OF SURVEY PERFORMED AND THE MAPPED FEATURES DEPICTED HEREON ARE IN TYD 38 .ss ACCORDANCE WITH THE REQUIREMENTS OF A PROPERTY & TOPOGRAPHIC SURVEY. Iln-195.66 / Z lout-195.61 / 3. BOUNDARY DETERMINATION/OPINION IS BASED UPON A DEPENDENT RESURVEY OF MAP / o' DRAINAGE EASEM T / REFERENCED IN NOTE 6A. ' � !!/ do REAR SETBACK f� 4. WI RESPECT TO THE BOUNDARY. THIS TH SURVEY O CLASS A-2. Z •RESPECT TO THE TOPOGRAPHY. THISS SURVEY CONFORMS CLASS T-2.WITH 13 10' D NAGE EASEMENT 5. BEARINGS AND NORTH ARROW BASED UPON MAP REFERENCE 6A. O z r 6c SI SETBACK /G 6. MAP REFERENCES: 9 a (V / • Know what's I1@IOW. I S to b A. "ESTATES OF SOUTH WINDSOR, GRAHAM ROAD AND NEVERS ROAD, SOUTH WINDSOR,04 z CONNECTICUT." DATED FEBRUARY 8, 2017, REVISED THROUGH AUGUST 3, 2017 W o Cell before you dig. I cv o n PREPARED BY MILONE & MACBROOM. (10 i IN CONNECTICUT CALL 811 OI OR 1 800-922�455 1 �J $ B. "PROPERTY SURVEY, TOLL BROTHER, GRAHAM AND NEVERS ROADS, SOUTH WINDSOR, W rI 4I0.75' 20 .8 ! 2. 203.8 !2W CONNECTICUT.,' SCALE 1"=100' DATE 11/12/16 REVISED 01/19/17 PREPARED BY DESIGN I 4100 8 1 1 + / to PROFESSIONALS. PROPOSED L O C. "COMPILATION MAP, MAP SHOWING EASEMENT AREA TO BE GRANTED TO THE ii � O CONNECTICUT LIGHT AND POWER COMPANY, d.b.a. EVERSOURCE ENERGY, ACROSS THE ff O DWEWNG to PROPERTY OF TOLL LAND XVIII, LLC, GRAHAM & NEVERS ROAD, SOUTH WINDSOR, CT." I F.F.=207.16 0 IL19 p I 204.8 cm -1 W=205.83 r CAI21 SCALE: 1 =80 DATED 8/22/17 , REVISED 8/29/17 PREPARED BY ESE CONSULTANTS. N tpl in G.F.L205.16 p. 0 I PROPOS D 8! B.r.=198.29$ I D. "COMPILATION MAP, MAP SHOWING EASEMENT AREA TO BE GRANTED TO YANKEE GAS / ( DRIVEW Y 14.1 .58'3' 9 SERVICES COMPANY, d.b.a. EVERSOURCE ENERGY, ACROSS THE PROPERTY OF TOLL LAND 12 09' I #7.83 I XVIII, LLC, GRAHAM & NEVERS ROAD, SOUTH WINDSOR, CT." SCALE: 1'=80' DATED N h1'�1'�ui 8/22/17 PREPARED BY ESE CONSULTANTS. ACKFLOW PREVENTOR S 20+'68 REQUIRED 7. FOOTING DRAIN AND ROOF LEADER TO BE TIED INTO CATCH BASIN #19. BACKFLOW I ` SEE NOTE 7 PREVENTOR IS REQUIRED AT THE INVERT OF THE FOOTING DRAIN AT THE HOUSE. 204.8 I` COVERED 8. THIS PLAN IS NOT VALID WITHOUT THE LIVE SIGNATURE AND EMBOSSED SEAL OF THE • I PORCH LICENSED LAND SURVEYOR. o � ; CONSTRUCTION STOCK 1 A--11*07'57" 9. THE LOCATION OF ALL UTILITIES ARE APPROXIMATE. THE EXACT LOCATION OF THE GAS AND ENTRANCE o u _ R=175.00' ELECTRIC SERVICES TO BE DETERMINED BY THE RESPECTIVE UTILITY COMPANY. THE STREET TREE ASEME T ..� / LOCATION AND INVERT OF THE SANITARY LATERAL SUBJECT TO CHANGE WITH THE L=34.00�tca/ INSTALLATION OF THE SANITARY SEWER MANHOLES. _ CUP E-ASEMEN __ - 10. PARCEL IS SUBJECT TO A STREET TREE EASEMENT, AN EASEMENT IN FAVOR OF THE ETC Er CONNECTICUT LIGHT AND POWER COMPANY, AN EASEMENT IN FAVOR OF YANKEE GAS W SERVICES COMPANY, AND A DRAINAGE EASEMENT. > 5 83'58'54W 81.21 �\ lin=19 yd3B) U 11. TEMPORARY AND PERMANENT SEEDING SHALL BE IN ACCORDANCE WITH THE APPROVED 0 qo2 -194.44(cb20) SEDIMENT AND EROSION CONTROL PLAN. SEE MAP REFERENCE A. Tin-192.64(cb 3:: Z 202.85,/ 223 LF 157_H O 4.26 -_ - lout-19 O SMH 6 I v� TF=20 ZONING DATA - RR ZONE TOLLAPPLILAND XVill LIMITED PARTNERSHIP Z w L) SMH 7 98 8" PVC d3.48X ' tln- 8 N w---fit= 42 OLD RIDGEBURY ROAD Q z ti°k /�� l;F 20299 °ti W DESCRIPTION REQUIRED PROVIDED SECOND FLOOR Z w out=19 / DANBURY, CONNECTICUT 06810 p O z -G G G G ~ _I' LOT AREA 20.000 SF 20,470 SF O i CD LONGMEADOW VE LOT COVERAGE 20% MAX. 16.1% 0- 0 Q� FRONT YARD 40' 43.52' • I VI N 08 3897-LOT 20 SIDE YARD 10' 19.56' FJ s STANSBURY TRADITIONAL - LH GRAPHIC SCALE REAR YARD 20' 76.22' CONTACT: N 3 CAR SIDE ENTRY GARAGE 8' BASEMENT MIN. FRONTAGE 75' 115.36' CHRIS BENNETT I . Z 30 0 30 60 (860) 478-0953 O W E OPTIONS MAX. BLDG. HEIGHT 30' 27.99- 001 - THREE CAR SIDE ENTRY GARAGE 022 - ALTERNATE LAUNDRY LOCATION IN FEET TO MY KNOWLEDGE AND BELIEF THIS MAP IS SUBSTANTIALLY s R F.�TAS PED HEREON. 046 - EXPANDED BASEMENT 1 = 30 FEET - L_J 047 - EXPANDED BASEMENT W/ SELECT OPTIONS „W„ 532 - PALLADIAN KITCHEN ADDITION ra \ xoTJL LOT sir 629 - ADDITIONAL DIRECT VENT FIREPLACE FAMILY ROOM • DOUGLAS S. 'C VER, CT P.L.S. #70458 RECEIVED JAN 29 2019 SOUTH WINDSpR ENGINEERING SOR 10 THi �i!'1;�•;a 0�Yi. ip'rYY OF SCU1N w;!eu�i?It This eertifi-d th-,t t'•, M•n •nd spuc,ficetinns are irfia aoPles of the proposed nuilding or alterations to bd erected at Street bgether with emendmnnt= stated in application an@ filed with plan and i 8u71dg sin and t cmPty with all aJq/qg, tale 1s,ch nrders as -hall be blued by the Bulld, og ,rtTent during Pendency of this apppcation and final permit. Issuance of a building Signed This plan Is opproved subject to the condition that orders and ordin,nees regulating building &halt be compiled K,th Conditionally APpvbved These filed wit b --------- 8ullding Inspector ' Cleq 1540 SULLIVAN AVENUE• SOUTH WINDSOR; CT 06074 SQII.co�� TELEPHONEcBs ): aa 2511 RECEIVED 3 J19. outh Win4igr AN ACT CONCERNING CONCRETE FOUNDATIONS: . Section 1(Public Act No.16-45)0&-W)(Effective October 1,2016)Prior to the issuance of a Certificate of Occupancy for a new residential or commercial building for which a concrete foundation was installed.on or after October 1,2016,the applicant shall provide the Building Official with written documentation of the name of the individual or entity that supplied the concrete and the name of the individual or entity that installed the concrete. Copies of such documentation shall be maintained in the records of the office of the Building Official for not less than fifty(50)years. Please fill the information in and submit to the Building Department: Date of information received/fded: Project location: Job description: .� '�--�h CONCRETES CONCRETE INSTALLER � Name: r`Nam: A � CVO (Please Print) (Please Print) Address: �i o X 1 3 Address: �7 1� Phone/Contact: 9 4 — 9 3 Phone Contact: 4 �� 1 APPLICANT/CONTRACTOR information: Name: - .(Please Print) Address: 3-7U � �- Phone/Contact: -Mail- Date: Signature: o REScheck Software Version 4.6.5 Compliance Certificate Project COLUMBIA II MODEL Energy Code: 2012 IECC Location: Glastonbury, Connecticut Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 4,988 ft2 Glazing Area 14% Climate Zone: 5 (6155 HDD) Permit Date: 01-11-19 Permit Number: 0020 Construction Site: Owner/Agent: Designer/Contractor: Estates at South Windsor Toll Brothers,Inc. Toll Brothers, Inc. 101 Longmeadow Dr. 250 Gibraltar Road South Windsor, CT 06033 Horsham, PA 19044 Compliance: Passes using UA trade-off Compliance: 3.7%Better Than Code Maximum UA: 570 Your UA: 549 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Basement Wall: Solid Concrete or Masonry 1,519 0.0 19.0 0.044 66 Wall height: 7.5' Depth below grade: 6.0' Insulation depth: 7.0' Basement Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.290 3 Exterior Wall First Floor 2x6:Wood Frame, 16" o.c. 974 21.0 0.0 0.057 35 Windows First Floor:Vinyl/Fiberglass Frame:Double Pane with Low-E 297 0.290 86 Entry Door:Solid 20 0.200 4 Glass Door: Glass 40 0.340 14 Garage Wall 2x6:Wood Frame. 16"o.c. 55 21.0 0.0 0.057 3 Garage Wall 2x4:Wood Frame, 16"o.c. 337 13.0 0.0 0.082 26 Door: Solid 18 0.200 4 Band joist:Wood Frame, 16"D.C. 427 19.0 0.0 0.060 26 Exterior Wall 2nd Floor 2x6:Wood Frame, 16"o.c. 1,605 21.0 0.0 0.057 77 Windows 2nd Floor:Vinyl/Fiberglass Frame:Double Pane with Low-E 261 0.290 76 Balloon Framed 2x6:Wood Frame, 16"o.c. 1,000 21.0 0.0 0.057 57 Flat Ceiling: Raised or Energy Truss 2,031 38.0 0.0 0.025 51 Sloped Ceiling:Cathedral Ceiling 161 30.0 0.0 0.034 5 Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Pagel of 9 186419-TBI-0020 Rescheck.rck Gross Area Cavity Cont. Assembly or U-Factor UA Floor over Garage: All-Wood joist/Truss:Over Unconditioned Space 497 30.0 0.0 0.033 16 Compliance Statement: The proposed building design described here is consi t ith. _ le�'ldig plans,specifications,and other calculations submitted with the permit application.The proposed building the 2012 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirem hdFkartSpEction Checklist. CO3 J' Name-Title Signature - Date Project Notes: : �'F -1�. in7`)_: Elevation: Aberdeen ,���`rj Options: 001,022,036095,036096,046,047,109,147,162,179,182,19�,7 �x,A39,�32,629,90020001,90020003 Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: C:\ Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\A0 Page 2 of 9 186419=TBI-0020 Rescheck.rck REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1)1 energy code compliance for the 641 building envelope. ,❑Not Observable ❑Not Applicable 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]I lighting and mechanical systems. 7 - ❑Not Observable Systems serving multiple : ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Coolin Cooling: U: Manual J or other methods g' ❑Not Observable approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: C:\ Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 3 of 9 186419-TBI-0020 Rescheck.rck section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R- R- []Does Not table for values. insulation is used,verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F0511 insulation installed per ❑Does Not AO manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.8 Conditioned basement wall ft ft ❑Complies See the Envelope assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. 4 distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not 14 insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.8 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not d ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA 11 MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 4 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1. Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable 4 ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not 1 with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable [Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not 4 AAMA/WDMA/CSA 101/I.S.2/A440 :[:]Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.4 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<_2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply ducts in attics are R- R- ❑Complies [FR12]1 insulated to 2tR-8.All other ducts R- R- ❑Does Not in unconditioned spaces or outside the building envelope are ❑Not Observable insulated to>_R-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,and filter boxes are ❑Does Not _4 sealed. []Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not 0 below 55 QF are insulated to >_R- ❑ 3 Not Observable []Not Applicable 403.3.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not []Not Observable . ❑Not Applicable 403.4.2 Hot water pipes are insulated to R- R- ❑Complies [FR1812 =?R-3. ❑Does Not ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA—Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 5 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .ID 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 6 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided.Vto ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable 0 ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions, and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation 0 requirement applies(FR10). Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN411 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA 11 MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 7 of 9 186419-TBI-0020 Rescheck.rck section Plans Verified field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & R .ID 402.1.1. Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.E[FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI211 Blown insulation marked every 300 ft2. `❑Not Observable '❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI311 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. � '❑Not Observable ❑Not Applicable 403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F1411 cfm/100 ft2 across the system or ft1— ft2 ❑Does Not <=3 cfm/100 ft2 without airAO ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.2.2.1 Air handler leakage designated ❑Complies (F12411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [1`19]2 installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 'on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4.1 ;Circulating service hot water ) ❑Complies [FI1112 ;systems have automatic or ❑Does Not accessible manual controls. i 14 ❑Not Observable ❑Not Applicable 403.5.1 ;All mechanical ventilation system ❑Complies {F125]2 -fans not part of tested and listed ' '1� `��E`<�� i '�'�'�""'� �'" �� r ' ❑Does Not HVAC equipment meet efficacy and air flow limits. [:]Not Observable ❑Not Applicable 404.1 75%of lamps in permanent ❑Complies [F1611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ❑Not Observable Does not apply to low-voltage lighting. ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\A0 Page 8 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. `❑Complies (FI7]1 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not vj systems have been provided. ❑Not Observable [Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 9 of 9 186419-TBI-0020 Rescheck.rck 2012 IECC Energy Efficiency Certificate Insulation . Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.34 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments w• APPLICATION FOR PLUMBING PERNUT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074 (PHONE) 860444-2511 EXT.230 PERMIT NUMBER: DEPARTMENT DECISION APPLICATION IS HEREBY: j v I APPROVED: BLDG.PERMIT NUMBER: DATE INSPECTOR LOCATION OF WORK: 10 ' APPLICANT: OWNER: TYPE OF STRUCTURE: W BUH DING t NAME: NAME: �/ ❑ADDITION �� � \ PHONE NUMBER PHONE NUMBER: ❑EXISTING BUILDING ADDRESS: ADDRESS: TYPE OF USE: IDENTIAL O COMMERCIAL PLUMBIN G INFOORMATION: FURTHER DESCRIPTI F WORK: TYPE OF INSTALLATION 1 CYO NO.OF TOMETS:�_STYLE..-tnLX-NO.OF BATHTUBS: - NO.OF SHOWERS: N NO.OF LAVATORIES:_�_ w NO.OF CATCH BASINS: NO.OF FLOOR DRAINS: ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY WINDOW? OYES ONO ESTIMATED COST: S SIZE OF WINDOW: SITE OF DUCTS: / R SEPTIC TANK: FEE ENCLOSED:S _ SITE OF WATER PIPING AND RISER: 3 q 1 WATER HEATER: TYPE MANUFACTURER FEE SCHEDULE:$19 PER$1 OF THE ESTIMATED COST. ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS $1.00 OVER (.26 CENT EDUCATIONAL FEE INCLUDED AS PART OF THE PERMIT FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: 3 E: P'' t STATE: C SIGNATURE OF APPLICANT: - DATE: tOlit I I APPLICATION FOR HVAC PERAIrr TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WMSOI ,CT 06074(PHONE)860-644-2511 EXT.230 DEPARTMENT DECISION PERMIT NUBBIIt APPLICATION IS HEREBY: I�C&5�q APPROVED; BIB PERMTTNUAMER- DATE SPECTOR LOCATION OF WORK APPLICANT: �+ OWNER: TYPE OF STRIICTURE: R•E•c>t�SEri CO.T��i . e<WBUNLDING NAME: f+A R4s 3 > S. OL SENA NAME: ! o'er • ,6 7-/7 Goa IN IC, 0 ADDITION PHONE Numi3 LfZO3L/,Z�, PHONBNUMBER_ ❑EXISTING BUILDING ADDRESS: 125 7 SO,7WWA ADDRESS: Z A IWA 753 J• $iox 3 89 G'1�R.Ai.r CJ"—, lAs� TYPE OF USE: 8 u� C�' Dte�{S /ao NCS/f-�9�1 Coau�crAl y. , P HVAC INFORMATION: /! FURT+JMDBSlCRI`l T[OwN�OF WOB& TYPE OF SYSTEM: EATING t/AIC 1AfSnWcL Vf'f-X IJ��i+`�+f�Cis TIYG: % L► AIX GO/.I nc-4/11/4 TOTAL HEAT LOSS CBTUHM 241&°F (HEAT LASS SHEET REQUIRED) DESCRIBE ALL HEATING EQUIPMFN'T(INCLUDE MAKE AMID MODEL NO.): 2 - CA 991 E3 515c2 >Q V C(2,T AFvc: / `t',g CC ESTIMATED COST:S l Gb AIR CONDITIONING: DESIGN TEM :OUTSIDE�-F DME�'F DIFFERENCE�F• FEE ENCLOSED.s 0 C►c#% "l S a P TOTAL FEAT GAIN(BTm)320 [J HEAT GAIN SHEET REQUIRED) DESCRIBE ALL COOLING EQ_UPMENT(IMM T )E MAKE AND MODEL NO.): FEE sCMUYuLE:SIB PER slope of Fsrff4ATF.D Corr. ROUND UP TO THE PNEICr THOUSAND ONCE THE PROJECT IS SlM OVER. (.26 CENT EDUCATIONAL FEE I]YCLITDID AS PART OF THE P Amn"Z) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED APED IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNEMCUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK- CoNTRACrORs LICENSE NO.: 1 'T4,—0 3o 3 t 29 -rypr,.. S I STAB G� SIGNATURE OF APPLICANT: DATEe o201 7b3�c Electric # APPLICATION FOR BUILDING PERMIT Plumbing#HVAC# �I L ��� �� ' �C� i1<� G �a Date: Sprinkler# Estimated Cost $ ©O FINAL PROVALS Building _ COMPLETE RED BOXED AREAS Permit Fee $ o . Engineering Occupancy Fee $ 3 0 0 Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee $ Appr.forJBU ► SIGN ON REVERSE SIDE 4 J Total Fee $ TO THEDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: T 5 Applicant Location of Work. �0( _40 l Lot No. 2 Q Applicant's Address agOW2 /I9 Tel # S&D•-r�,q- `jdl0 Town !1 N G Lic.#�� �3i.2 Owner /o 5 Architect Zi yid Owner's Address Architect's Address ''/Sd Zip /7��'S /» P zip-- Sq. Ft. New Area: 1 st FI. 2nd FI. 5 3rd FI. Total New Area 3�o Purpose of this permit �e5� en��21 ei✓ Con�{�.rC S44rf City Water Well :3 Septic System J Sewer .St-" Ins: HO Spi Area Basement Garage Approved by Date.2 Use Group Construction Type A q) to I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use;,s;al�lowe Sign -- I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed_ z DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS INSPECTION FIELD SHEET 04/13/22 Printed by Middleton, Morgan 09 50 17 INSPECTION: 122768 FINAL PERMIT: STATUS APPLICATION: 201900208 LOC: 101 LONGMEADOW DRIVE SOUTH WINDSOR PROPERTY ID: 54670101 OWNER: TOLL LAND XVIII LIMITED PARTNERSHIP CONTRACTOR: TOLL LAND XVIII LP 860-944-9610 REQUEST BY: PROJ DESC: NEW SINGLE FAMILY HOME 3,300 SQ FT WORK ORDER: INSPECTOR: DOUG RESULT: PASS REQUESTED: PRIORITY: SCHEDULED: COMPLETED: 10/10/19 UNPAID FEES 00 Date Time MILEAGE: .00 TIME: TRAVEL ONSITE COMMENTS: RECVD DOCUMENTS FOR ISSUEB B10 ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 03/12/19 ROSE PASS B001 FOOTING 03/19/19 DOUG PASS B002 FOUNDATION 03/20/19 ROSE PASS B002 FOUNDATION REBAR 03/28/19 ROSE PASS B002 FOUNDATION BACKFILL//DAMPROOFING &FTG DRAIN/ ROOF LEADERS 07/10/19 ROSE PENDING B003 FRAMING (ROUGH) FILL NAIL HOLES OF I JOIST HANGERS (GARAGE) NEED HANGER SUPPORT FOR HEADER (1ST FL STAIR) MISSING I JOIST HANGER ROOM ADJACENT TO STAIR. (2 ND FLOOR ) MENDING PLATE FOR SEVERED WALL PLATE. QUERY KICKER PLATE FOR TRUSS ON SHEATHING. MISSING FIRE BLOCK AT FLOOR HEIGHT (LONG COLUMN) 07/18/19 ROSE PASS B004 INSULATION RECHECK FRAMING 10/07/19 ROSE PENDING B010 FINAL C/O NEED VENT AT HIGH POINT OF TRAP WASTE. SEAL UNDERSIDE OF FIREPLACE OVERHANG. NAIL HIP PIECES BETWEEN TRUSSES ABOVE (FURNACE PLATFORM) I INSPECTION FIELD SHEET 04/13/22 Printed by Middleton, Morgan 09 50 17 10/09/19 ROSE PENDING BO10 FINAL TO REPAIR BROKEN TRUSS MEMBERS(243233) .AS PER TRUSS ENG. SEALED SUBMITTAL. 06/03/19 ROSE PASS E001 ELECTRIC SERVICE RELEASED TO EVERSOURCE/ CRS#3275027 04/02/19 ROSE PASS E002 ELECTRIC UNDERGROUND CONDUITS 07/10/19 ROSE PASS E003 ELECTRIC ROUGH 07/10/19 ROSE PASS H003 HVAC ROUGH 04/02/19 DOUG PASS P002 PLUMBING UNDERGROUND 07/10/19 ROSE PASS P003 PLUMBING ROUGH WATER TEST RG PLBG /TEST ON WATER PIPES 10/10/19 DOUG PASS P004 PLUMBING GAS TEST 10/09/19 LIPE PASS Z003 CO PLANNING INSPECTION REScheck Software Version 4.6.5 Compliance Certificate Project COLUMBIA II MODEL Energy Code: 2012 IECC Location: Glastonbury, Connecticut Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 4,988 ft2 Glazing Area 14% Climate Zone: 5 (6155 HDD) Permit Date: 01-11-19 Permit Number: 0020 Construction Site: Owner/Agent: Designer/Contractor: Toll Brothers, Inc. Toll Brothers, Inc. 250 Gibraltar Road Horsham, PA 19044 Compliance: Passes using UA trade-off Compliance: 3.7%Better Than Code Maximum UA: 570 Your UA: 549 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Basement Wall: Solid Concrete or Masonry 1,519 0.0 19.0 0.044 66 Wall height: 7.5' Depth below grade: 6.0' Insulation depth: 7.0' Basement Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.290 3 Exterior Wall First Floor 2x6:Wood Frame, 16" o.c. 974 21.0 0.0 0.057 35 Windows First Floor: Vinyl/Fiberglass Frame:Double Pane with Low-E 297 0.290 86 Entry Door: Solid 20 0.200 4 Glass Door: Glass 40 0.340 14 Garage Wall 2x6: Wood Frame, 16" o.c. 55 21.0 0.0 0.057 3 Garage Wall 2x4: Wood Frame, 16" o.c. 337 13.0 0.0 0.082 26 Door: Solid 18 0.200 4 Band joist: Wood Frame, 16"o.c. 427 19.0 0.0 0.060 26 Exterior Wall 2nd Floor 2x6:Wood Frame, 16"o.c. 1,605 21.0 0.0 0.057 77 Windows 2nd Floor:Vinyl/Fiberglass Frame:Double Pane with Low-E 261 0.290 76 Balloon Framed 2x6: Wood Frame, 16"o.c. 1,000 21.0 0.0 0. 5�7�57 Flat Ceiling: Raised or Energy Truss 2,031 38.0 0.0 0.025 51 Sloped Ceiling: Cathedral Ceiling 161 30.0 0.0 0.03� 5 Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: C:\ Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Pagel of 9 186419-TBI-0020 Rescheck.rck Gross Area Cavity Cont. Perimeter Floor over Garage: All-Wood Joist/Truss:Over Unconditioned Space ` 049-h i r,,11 30.0 0.0 0.033 16 .`"" of CON "/, Compliance Statement. The proposed building design described here is consistot<<uith. (�yy J��'Ah*b ans,specifications,and other calculations submitted with the permit application.The proposed building has t3p,�: n d f�a 2012 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirement IisteeTicptYle IAI*k Checklist. Javv Name-Title Signature = Date Project Notes: %Fys.._���... FG�\ Elevation: Aberdeen ,,Fn ARCY".�,\`� Options: 001,022,036095,036096,046,047,109,147,162,179,182,196,205,I3`1',235,5\32,629,90020001,90020003 Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: C:\ Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 2 of 9 186419-TBI-0020 Rescheck.rck CREScheck Software Version 4.6.5 �J( Inspection Checklist Energy Code: 20121ECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.1113 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building e.envelo [-]Not Observable Ut P ❑Not Applicable 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 'lighting and mechanical systems. ❑Not Observable Systems serving multiple []Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: [ Complies 403.6 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr [:]Not Observable approved by the code official ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: C:\_Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 3 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified it Foundation Inspection Value Value Complies? Comments/Assumptions &Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04)1 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05)1 insulation installed per ❑Does Not IV manufacturer's instructions. ❑Not Observable []Not Applicable 402.2.8 Conditioned basement wall ft ft ❑Com lies See the Envelope Assemblies [FO6)1 insulation depth of burial or ❑Doe sNot table for values. 0 distance from top of wall. ❑Not Observable ❑Not Applicable OCom lies [O11]2 to prtective covering is otect exposed exterortalled ❑Do spNot insulation and extends a minimum of 6 in. below grade. []Not Observable ❑Not Applicable I 403.8 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. []Does Not b, []Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 4 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ; []Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR411 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 ':Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.4 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm .leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply ducts in attics are R- R- ❑Complies [FR12]1 insulated to>_R-8.All other ducts R- R- ❑Does Not in unconditioned spaces or outside the building envelope are [:]Not Observable insulated to>_R-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,and filter boxes are ❑Does Not sealed. ❑Not Observable ❑Not Applicable 403.2.3 'Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ,14 ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to>_R- 3 ❑Not Observable ❑Not Applicable 403.3.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not `,❑Not Observable i❑Not Applicable 403.4.2 Hot water pipes are insulated to R- R- ❑Complies [F1118]2. '>_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: C:\_Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 5 of 9 186419-TBI-0020 Rescheck.rck i Section Plans Verified Field Verified # Framing/Rough-In Inspection i Value Value Complies? Comments/Assumptions & Req.ID 403.5 Automatic or gravity dampers are ❑Complies [FR1911 installed on all outdoor air []Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 6 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not 0; provided. ❑Not Observable ❑Not Applicable 402.1.1. Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions,and ❑Does Not [IN2]1 in substantial contact with the V underside of the subfloor. ❑Not Observable - '❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation fo requirement applies(FR10). Steel Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. []Does Not []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA 11 MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\13ocuments\A0 Page 7 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verifled Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &R .ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1. ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.E[FI111 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every 300 ft2. "'❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. []Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI3]1 insulation >_R-value of the ❑Does Not adjacent assembly. [-]Not Observable ❑Not Applicable 402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not 4 <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air []Not Observable handier @ 25 Pa. For rough-in .tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.2.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10)2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. []Not Observable ❑Not Applicable 403.5.1 All mechanical ventilation system ❑Complies [FI2512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 404.1 75%of lamps in permanent `' <` ❑Complies (FI6]1 fixtures or 75%of permanent ` .r ❑Does Not fixtures have high efficacy lamps :+ a Does not apply to low-voltage -$ x x ❑Not Observable lighting. ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: C:\_Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\Documents\AO Page 8 of 9 186419-TBI-0020 Rescheck.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 404.1.1 Fuel gas lighting systems have ❑Complies [FI2313 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. []Complies [FI71z ❑Does Not 14 ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI1813 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: COLUMBIA II MODEL Report date: 01/14/19 Data filename: CA Vault\Communities\Connecticut\Estates at South Windsor\Lots\0020\DocumentsW0 Page 9 of 9 186419-TBI-0020 Rescheck.rck 2012 IECC Energy Efficiency Certificate Insulation . Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating Window 0.29 Door 0.34 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments 201900517 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF OCCUPANCY DATE: 10/10/2019 FEE: GIS ID: 54670101 ZONE: MUNIS APPLICATION# 201900208 THIS IS TO CERTIFY THAT 101 LONGMEADOW DRIVE UNDER APPLICATION NUMBER 201900208 CONFORMS SUBSTANTIALLY TO THE REQUIREMENTS OF THE CONNECTICUT BASIC BUILDING CODE AND THE ZONING REGULATIONS OF THE TOWN OF SOUTH WINDSOR AND IS HEREBY APPROVED OF OCCUPANCY AS INDICATED BELOW: µ APPROVED FOR OCCUPANCY NEW SINGLE FAMILY HOME 3,300 SQ FT SPECIAL CONDITIONS NOTICE: IF THIS CERTIFICATE IS LOST OR DESTROYED,A DUPLICATE SHOULD BE OBTAINED IMMEDIATELY FROM THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 10/10/2019 1:24 PM ANY CIIANGE OR EXTENSION OF THE USE HEREIN APPROVED REQUIRES ANEW CERTIFICATE OF OCCUPANCY 1900099 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 02/26/2019 GIS ID: 54670101 FEE: 4284.00 MUNIS APPLICATION# 201900208 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: TOLL LAND XVIII LP ADDRESS: 101 LONGMEADOW DRIVE ADDRESS: 2840 HEBRON AVENUE OWNER: TOLL LAND XVIII LIMITED PARTNERSHIP 42 OLD RIDGEBURY ROAD GLASTONBURY,CT 06033 DESCRIPTION OF WORK: NEW SINGLE FAMILY HOME 3,300 SQ FT SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY T BUILDING DEPARTMENT. CONSTRUCTION TYPE: 9-A� OCCUPANCY GROUP: BUILDIf OFFICIAL 2/26/2019 9:21 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1900584 TOWN , CT PERMIT NUMBER HVAC PERMIT DATE: 09/20/2019 GIS ID:54670101 FEE: 270.00 MUNIS APPLICATION# 201902050 BUILDING DESCRIPTION: APPLICANT°' LOCATION NAME: A.E.OLSEN CO, INC ' ADDRESS: 101 LONGMEADOW DRIVE ADDRESS: 1257 SOUTHFORD ROAD OWNER: TOLL LAND XVIII LIMITED PARTNERSHIP P.O. BOX 388 42 OLD RIDGEBURY ROAD SOUTHBURY,CT 06488 P DESCRIPTION OF WORK: INSTALL GAS FURNACE&CENTRAL AC SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND'PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 9/20/2019 9:04 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1900371 PERMIT NUMBER PLUMBING PERMIT DATE: 07/19/2019 GIS ID:54670101 FEE: 234.00 MUNIS APPLICATION# 201900208 BUILDING DESCRIPTION: APPLICANT X,.�", LOCATION NAME: GEM PLUMBING : ` ADDRESS: 101 LONGMEADOW DRIVE ADDRESS: 495 CHIPMAN STREET,;,, OWNER: TOLL LAND XVIII LIMITED PARTNERSHIP 42 OLD RIDGEBURY ROAD WATERBURY,CT 06708 DESCRIPTION OF WORK: NEW SINGLE FAMILY HOME 3,300 SQ FT J � k tr SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: _ N BUILDING OFFICIAL 7/19/2019 7:52 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE