Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10 GILBERT LN
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A 2( RESIDENTIAL BUILDING PERMIT APPLICATION? ❑ YES ❑ NO O BUSINESS CURRENT USE AND OCCUPANCY O ASSEMBLY O MERCANTILE O EDUCATIONAL FUTURE USE AND OCCUPANCY O FACTORY O STORAGE ENGINEER'S NAME PHONE O GARAGE O MIXED USE ADDRESS (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION (VP(, ( cn JJ-ru d/"f1USIZE OF MAIN DRAIN `t NO.OF TOILETS STYLE NO.URINALS — STYLE �— NO. OF BATHTUBS � NO. OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW O YES O NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK r � n PGv Zr-a P ��-� r,,,k r�/z h G 1 V � 2 i Ar, f G L-61 kr�fr &,''n/�t y e.A'Pti Ld, de Ali o-ef, 67 62/9f' `kvr (,o1f THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 0)- 03 )- 72 CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE___( _ 30` 17 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is TOWN OF SOUTH WINDSOR > i BUILDING DEPARTMENT #_/;P OVED 1540 SULLIVAN AVENUE Bldg.Pennit# �9- 644-2511 EXT.230 (Date) uilding Inspector) Application must be printed or typed FEE SCHEDULE " �f Jo $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000- $15.00 per$1,000 _ or any fraction thereof Tenant Designation Apt.No. APPLICANT C "I fiY Pt Ombj X.o co . APPLICANT ADDRESS 109 �f J�' Vernon T y(aU(n APPLICANT PHONE# 94PO-?'?S OW N 8t OWNER JCkC-Q tleS C-OY1,�- VUc+ion OWNER ADDRESS OWNER PHONE ( C) #' C ESTIMATED COST $ IS THIS A CONTRACT COST? ✓ YES NO CJ FEE ENCLOSED$ — TYPE OF JOB: �D l l 0R'C0� ✓ New Installation Alteration/Addition Repair ,2Of (3C Revised 12/22/11 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑ RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑. ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL; ❑ INSTITUTIONAL ENGINEER'S NAME PHONE: ❑ FACTORY Cl- STORAGE ADDRESS ❑ GARAGE . 0 MIXED USE CITY STATE ZIP (Other please`specify) TYPE OEINSTALLATION/WIRING METHOD, $IZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBERS OF METERS NUMBERS.OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES. NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER'OF A/C CIRCUITS. SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE-SUBMITTED. DESCRIPTION OF WORK OF THE UNDERSIGNED NEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANi�, D- G I „� DATE I APPLICATION FOR..ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVED 1:540 SULLIVAN AVENUE 644-2511.ext. 230 Bldg:.Permit# Date Building Inspector 1 76D �i11 d Application must be printed or typed FEE SCHEDULE H d Location,of Job: $o-$1,000 $15.00 Over$1,000= Street No. Street Lot No. $15.00.per$1,000 . or any fraction thereof Tenant Designation Apt:No. APPLICANT APPLICANT ADDRESS P d BOX 3 u�AWA) �T APPLICANT'S PHONE# 960 Ua-16-a 5'1 �pW N SF�4 OWNER 7% C a Q 0:1� ULA T R tj 0,7 Zp OWNER ADDRESS ' SC) CV LrW5,0/1 (f 1- OWNER PHONE �6 0 1-113a- 1S 3 Q.. ESTIMATED COST$ /0, 000 O� "I U IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$—f 66*e?1!�P— ($0 r o TYPE OF JOB: k"I q v— 41(0 Q New Installation Alteration/Addition/Repair Revised 03/05/10 Electric # APPLICATION FOR BUILDING PERMIT Plumbing# HVAC# I h C��Irk ��InQ Date: �1 ✓� �' �(��� Sprinkler# [1vU-3Lfc, FINAL APPROVALS Estimated Cost $ ct Permit Fee $ 41z b Buildin COMPLETE RED BOXED AREAS Occupancy Fee $ 1 0 Engineeringir TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit Appr.forTBUIDING ► SIGN ON REVERSE SIDE 4 Total Fee $ `tr9 9 0 TO THE DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ ��q The undby applies to do work according to the following: Applicant. '-1 Location of Work 0 6 Lot No. Applicant's A re Tel # Towns O -4 Zip Lic.# 7r3c� Owner ri,�p1�LQi Architect 1 S Owner's Address Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 1 2nd Fl. J-- / 3rd FI. Total New Area Purpose of this permit 4e cine City Water Y Well J Septic System :J Sewer .2e/7a)o/ Ins: HO SP Cert. Area Basement � Garage Approved by Date - Use GroupC Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to b located the pro er distance from all street lines,side yard lines,and required distances from all other zones and is located in ich this build d its use is allowed. Signed I hereby apply for a Certificat of Occupan or t'a or cribed in this application for the permit. Signed OT WRITE Y� rs'/LINE v' INSPECTION 68MMENTS 4f � vac D�✓�— � �� _ a INSPECTION FIELD SHEET O1/18/18 Printed by Foreshaw, Dayshell 09 06 58 TO PROVIDE ACCESS PANEL TO PLBG CLEANOUT AND SHUT OFF VALVES ON RISER WATER PIPES O1/03/18 ROSE N/A E002 ELECTRIC UNDERGROUND O1/03/18 ROSE N/A B005 FIREPLACE / CHIMNEY O1/03/18 ROSE N/A B002 FOUNDATION O1/05/18 ROSE PENDING BO10 FINAL NOT READY THE FOLLOWING NOT DONE: -HEATING DIFFUSERS NOT IN PLACE. -DUCT WORK TO BE VACCUMED. -HANDRAILS BASEMENT STAIRS NOT DONE. - DECK STAIR HANDRAILS NOT IN PLACE. -CONTR. TO SUBMIT CERTIFICATION OF BLOWN ATTIC INSULATION. -TO SUBMIT RESULTS OF BLOW DOOR TEST. -IECC LABEL OF INFO. ELEC. PANEL. -ELEC. CONTR. TOUBLESHOOTING WORK IN PROGRESS -BOND OF GAS PIPING. -INSULATE PIPE HOT AND COLD WATER PIPE TO WATER HTR. -GARAGE NOT ACCESSIBLE DUE DEBRIS STORED. O1/11/18 FOLG PASS Z003 CO PLANNING INSPECTION O1/11/18 ROSE PENDING BO10 FINAL GARAGE RECEPTACLES OUTLET TO BE GFCI PROTECTED. NEED ONE SIDE GRASPABLE HANDRAIL FOR DECK STAIRS O1/12/18 ROSE PENDING E010 ELECTRIC FINAL RECHECK./ /GARAGE RECEPTACLES TO BE GFCI O1/16/18 ROSE PASS BO10 FINAL INSPECTION FIELD SHEET O1/18/18 Printed by Foreshaw, Dayshell 09 06 58 z 1 INSPECTION: 95225 FOOTING PERMIT: STATUS APPLICATION: 201700619 LOC: 10 GILBERT LANE SOUTH WINDSOR PROPERTY ID: 35300010 LOT/SUBDIV: 3 OWNER: JACQUES CONSTRUCTION 860-432-1823 CONTRACTOR: REQUEST BY: PROJ DESC: NEW HOME. WORK ORDER: INSPECTOR: ROSE RESULT: PASS REQUESTED: 05/31/17 PRIORITY: SCHEDULED: 06/02/17 AM COMPLETED: 06/02/17 UNPAID FEES 00 Date Time MILEAGE 00 TIME: TRAVEL ONSITE COMMENTS ALL INSPECTIONS INSPECTED INSPECTOR RESULT INSP DESCRIPTION 09/01/17 ROSE PASS P002 PLUMBING UNDERGROUND WATER TEST ON UNDERGD SAN. PLBG. 09/28/17 ROSE PASS P003 PLUMBING ROUGH WATER TEST ON WASTE & VENTS /PRESS TEST ON WATER PIPES 09/28/17 ROSE PENDING B003 FRAMING (ROUGH) NEED TO SUPPORT I JOIST AND HEADER WITH THE APPROPIATE HANGERS WALL BRACING AS NOTED IN SUBMITTAL FOR RAFTERS NOT DONE 09/28/17 ROSE PASS E003 ELECTRIC ROUGH 09/28/17 ROSE PASS H003 HVAC ROUGH 10/12/17 DOUG PASS B004 INSULATION RECHECK ON FRAMING OK 10/20/17 DOUG PASS P004 PLUMBING GAS TEST 10/26/17 ROSE PENDING E001 ELECTRIC SERVICE CANNOT LOCATE DRIVEN RODS CONTR. NOTIFIED. 11/13/17 ROSE PASS E001 ELECTRIC SERVICE OK TO RELEASE TO EVERSOURCE 11/16/17 DOUG PASS E003 ELECTRIC ROUGH BASEMENT AND BONUS ROOM. 11/29/17 ROSE PASS B004 INSULATION FULL BASEMENT I APPLICATION FOR HVAC PERMIT(Continued from ieverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING 0 RESIDENTIAL Ll A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT.HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT BTUH) T NET RATING(OUTPUT-BTUH): TYPE OF FUEL - ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE °F INSIDE °F DIFFERENCE °F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 4� C � oN 3 . r (49 TONNAGE / COOLING CAPACITY(BTUH) / lam VENTILATION DESCRIBE ALLAIR HANPLING EQUIPMENT CLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) �, FRESH AIR INTAKE(CFM) ✓�`�� (PLANS MUST ACCOMPANY APPLICATION) . FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE-0- l -7 APPLICATION FOR HVAC PERMIT DEPARTMENT_�CISION TOWN OF SOUTH WINDSOR PERMIT# Application its her4by: BUILDING DEPARTMENT l.�0�.3 ✓ AP OOVER 1540 SULLIVAN AVENUE Bldg.Permit# - -/ 644-2511 ext. 230 DW` ��?c��3�� Date 'lding Inspector Application must be printed or typed FEE SCHEDULE h /l Location of Job: $041,000=$15.00 /ram _ `''i��� &Ivl�i Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.,No. APPLICANT y� APPLICANT ADDRESS-" '00 /--o C 'el' APPLICANT'S PHONE# a 0?0 OWNER "(OW N SFq< OWNER ADDRESS _, AZI L.1) , OWNER PHONE `# F" ESTIMATED COST$ C �U IS THIS.A CONTRACT COST? Yes No V FEE ENCLOSED$ TYPE OF JOB: '?q jo OR-Co New Installation Alteration/Addition/Repair Revised 03/05/10 SPECIFICATIONS \ Heating Capacity and Efficiency 30040 42060 48080 60080 60100 66120 Input High Heat (BTUH) 40,000 60,000 80,000 80,000 100,000 120,000 Low Heat (BTUH) 26,000 39,000 52,000 52,000 65,000 78,000 Output High Heat (BTUH) 39,000 58,000 78,000 78,000 97,000 117,000 Low Heat (BTUH) 25,000 38,000 50,000 51,000 63,000 76,000 Efficiency AFUE%(ICS) 95.5 95.5 95.5 95.5 95.5 95.5 High Heat 40-70 40-70 40-70 40-70 40-70 40-70 Certified Temperature Rise Range OF(°C) (22-39) (22-39) (22-39) (22-39) (22-39) (22-39) Low Heat 30-60 30-60 30-60 30-60 1 30-60 30-60 (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) Airflow Capacity and Blower Data 30040 42060 48080 60080 60100 66120 Certified External Static Pressure(in.w.c.) Heating 0.10 0.12 0.15 0.15 0.20 0.20 Cooling 0.5 0.5 0.5 0.5 0.5 0.5 High Heat 695 1000 1360 1360 1700 2125 Airflow Delivery @ Rated ESP(CFM) Low Heat 590 785 1095 1055 1325 1610 Cooling 925 1505 1610 2015 2110 2055 Cooling Capacity(tons)@ 400,350 CFM/ton 400 CFMtton 2 3.5 4 5 5 1 5 350 CFMtton 2.5 4 4.5 5.5 6 6 Direct-Drive Motor Type Electronically Commutated Motor(ECM) Direct-Drive Motor HP 1/2 3/4 3/4 1 1 1 1 Motor Full Load Amps 6.8 8.4 8.4 10.9 1 10.9 10.9 RPM Range 600-1200 Speed Selections 5 Blower Wheel Dia x Width in. 11 x 7 11 x 8 11 x 8 I 11 x 10 111 x 10 11 x 11 Air Filtration System Field Supplied Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR Electrical Data 30040 42060 48080 60080 60100 66120 Input Voltage Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Input Amps Amps 7.5 9.2 9.2 11.7 11.8 11.8 Unit Ampacity Amps 10.3 12.4 12.4 15.5 15.6 15.6 Minimum Wire Size AWG 14 14 14 12 12 12 Maximum Wire Length @ Minimum Wire Size Feet 36 29 29 37 36 36 (M) (11.0) (8.8) (8.8) (13.3) (10.7) (11.0) Maximum Fuse/Ckt Bkr Amps 15 15 15 20 20 20 (Time-Delay Type Recommended) Transformer Capacity(24vac output) 40 VA External Control Power Available Heating 24.3 VA Cooling 34.6 VA Controls 30040 42060 1 48080 1 60080 60100 66120 Gas Connection Size 1/2"-NPT Burners(Monoport) 2 3 4 1 4 5 6 Gas Valve(Redundant) Manufacturer White Rogers Minimum Inlet Gas pressure(in.wc) 4.5 Maximum Inlet Gas pressure(in.wc) 13.6 Gas Conversion Kit-Natural to Propane KGANP51012SP Gas Conversion Kit-Propane to Natural KGAPN43012SP Manufactured(Mobile)Home Kit not approved for MH use Ignition Device Silicon Nitride Limit Control 165 180 1 170 1 200 1 180 160 Heating Blower Control(Heating Off-Delay) Adjustable:90,120,150,180 seconds Cooling Blower Control(Time Delay Relay) 90 seconds Communication System none Thermostat Connections Com 24V,R,W/W1,G,Y/Y2,DRUM,Y1,W2 Accessory Connections EAC(115vac);HUM(24vac);1-stg AC(via YN2) 3 SPECIFICATIONS UNIT SIZE 018 0241 030 036 042 048 060 SERIES B B B B/C B/C B/C B/C ELECTRICAL Unit Volts-Hertz-Phase 208/230-60-1 008/230-60-1 208/230-60-3 208/230-60-1 208/230-60-1 208/230-60-3 208/230-60-1 208/230-60-3 Operating Voltage Range* 187-253 Compressor-Rated Load Amps 9.0 13.5 12.8 14.1/17.3 9.0 17.9/21.8 19.9/20.5 13.1 26.4/27.6 16.0 Locked Rotor Amps 48.0 58.3 64.0 77.0/96.7 71.0 112.0/105.0 109.0/115.0 83.1 134.0/135.0 110.0 Condenser Fan Motor-Full Load Amps 0.5 0.8 0.8 1.4 1.4 1.1 1.4 1.4 1.4 1.4 Min Unit Ampacity for Wire Sizing 11.7 17.6 16.8 17.6/23.0. 12.7 23.5/28.4 26.2/27.0 17.8 34.4/35.9 21.4 Min Wire Size 60°/75*Cop er AWG** 14 12 12 12 14 10 8 12 8 12 Max Wire Length(60°/751 It(m)# 66/62 70/66 74/70 70/66 70/67 83/79 115/109 70/66 89/82 66/63 (20.1/18.9) (21.3/20.1) 22.6/21.3 (21.3/20.1) 21.3/20.4 (25.3/24.1) (35.1/33.2) (21.3/20.1 27.1/25 0 (20.1/19.2) Max Branch Circuit Fuse Sizet 1 20 1 30 1 25 30 20 40 40 25 50 30 COMPRESSOR AND REFRIGERANT Type Scroll Temperature and Current Protection Internal Line Break R-41OA Refrigerant- 3.15(1.43) 3.15 1 43 %20(2.82)/ Amount Uo @ 15 ft 4.6 m (• (1.65) 4.67(2.12) 6 07 2 75 7.67 (3.48)/7.19(3.27) 8.00(3.64)(8.5(3.86) Refrigerant Tubes(In.OD) ## Rated Va or an Maximum U uid 3/4 and 3/8 7/8 and 3/8 1-1/8 and 3/8 d CONDENSER COIL AND FAN Coil Face Area(Sq Ft) 8.4 1 8.4 9.8 12.60 17.3 21.63 15.14 Fan Motor-HP Type,and RPM 1/12 PSC and 1100 1/10 PSC and 1100 114 PSC and 1100 1/5 PSC and 1/4 PSC and 1100 1100 Volts-Hertz-Phase 208/230-60-1 Condenser Airflow(CFM) 1700 2000 1 2000 2500 3000 3400 3400 OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist-PTC Type KAACS0201 PTC I N/A KAACS0201 PTC N/A KAACS0201 PTC N/A Start Assist-Capacitor/Relay Type KSAHS1501AAA KSAHS1701AAA KSAHS1501AAA N/A KSAHS1501AAA N/A KSAHS1501AAA N/A MotorMasterO Control KSALA0601 AAA Ball Bearing Fan Motor(RCD) HC32GE234 HC34GE239 HC40GR232 HC38GE219 HC40GE226 Low-Pressure Switch KAALP0401 PUR W High-Pressure Switch KAAH10501PUR Compressor Sound Hood KSASH1801COP KSASH0601COP KSASH2101COP Time-Delay Relay KAATD0101TDR Low-Ambient Pressure Switch Kit KSALA0301410 Winter Start Control KAAWS0101 AAA Evaporator Freeze Thermostat KAAFT0101AAA Compressor Crankcase Heater KAACH1401AAA KAACH1201AAA Liquid Line Solenoid Valvett KAALS0201 LLS TXV Hard Shuto tt KSATX0201PUR KSATX0301PUR KSATX0401PUR KSATX0501PUR Standard Thermostat,Manual Changeover,Non-Programmable,*F/°C, TSTATPPBAC01 1-Stage Heat,1-Stage Cool Thermostat,Auto Changeover,7-Day Programmable,°F/°C,1-Stage Heat, TSTATPPPAC01 1-Stage Cool Outdoor Sensor TSTATXXSENOi-B U uid Line Filter Drier KH43LG073 KH43LG074 Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBPOI N/A-Not applicable in this application. *Permissible limits of the voltage range at which unit will operate satisfactorily.Operation outside these limits may result in unit failure. t Time-delay fuse or circuit breaker. #Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. **If wire is applied at ambient greater than 30°C,consult Table 310-16 of the NEC(ANSI/NFPA 70).The ampacity of nonmetallic-sheathed cable(NM),trade name ROMEX,shall be that of 60*C conductors,per the NEC (ANSI/NFPA 70)Article 336-26. tt Do not use hard shutoff TXV with liquid solenoid valve. ##Units are rated with 25 ft(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. DIMENSIONS - SERIES B - ENGLISH UNT SERFS R EMOCAL A B C D E F G H J K L M N P DPERATM �ff D �F ° CHARACTERISTICS WB%ff WPOHT DWSIDNS L x W x HI PA13NA018 B X 0 0 0 23 1/$' 24 13/16• 3 3/4' 3/4' 4 7/16' 18 1116' 7 13/16' 5/16' 3' 2 13/16' 1/2' 12' 11 3/4' 11 7/8' 1049 1206 24 1/8' X 24 1/8' X 27 3/16' PA13NA024 B X 0 0 0 23 1/8' 24 13/16' 3 3/4' 3/4' 4 7/16' 18 1116' 7 13/16, 5/16' 3' 2 131161 1/2, 12' 11 3/4' 11 7/8' 1079 1239 24 1/8' X 24 1/6' X 27 3/16' PA13NA030 8 X 0 0 0 23 1/8' 28 7/16' 3 3/4' 3/4• 4 7/16' 18 1/16' 1 13/16' S/16' 3' 2 13/16' 1/2• 12, 11 314, 12/2' 1109 1269 24 118' X 24 1/8' X 30 5/8' PA13NA036 B X 0 0 0 23 1/$' 35 3/16' 3 7/8' 1/0' 4 7/16' 18 1116' 7 13114' 5/16, 3' 2 13/16' 1/2' 12' 11 3/4' 13 3/4' 1229 1399 24 1/8' X 24 1/5' X 37 7/16' PA13NA042 B X 0 0 0 31 3/16• 31 13/16' 3 7/8' 7/8' 6 1/16' 24 11116' 9 118' 5116' 3' 2 15116, 5/8, 16' 15 1/2' 13 3/4' 1649 1879 32 3116• X 32 3/16• X 34• PA13MA048 B X 0 0 0 1 31 3/16' 1 30 5/8' 1 3 7/8' 1 7/8' 1 6 9/16' 124 11/16'1 9 1/8' 1 5/16' 1 3' 2 15/16'1 5/8' 1 16' 15 1/2' 1S 1/2' 1 1816 2066 32 3/16' X 32 3116' X 40 13116' PA13MAOSO B X 0 0 0 31 3/16' 28 1/16• 3 7/8' 7/8' 6 9/16' 24 11116' 9 1/8' 5/16' 3' 2 15116' 5/8' 16' 15 1/2' 12 3/1. 1909 2169 32 3/16' X 32 3/16' X 30 5/8• PA13PA036 B 0 0 X 0 23 1/11' 35 3/16' 3 7/8' 7/8' 4 7/16' 18 1116, 1 13/16, 5/16• 3' 2 13/16, 112, 12' 11 3/4' 13 3/4• 1226 1399 24 1/8' X 24 1/8' X 37 7/16' PA13PA048 B 0 0 X 0 31 3/16' 38 5/8' 3 7/8' 7/8' 6 9/16' 24 11/16' 9 1/8' 5/16' 3' 2 15/16' 5/8' 16• 15 1/2' 15 1/2' 181E 2061 32 3/16' X 32 3/16' X 40 13/16' PA13PA060 B 0 0 X 0 31 3/16• 1 28 7/16' 3 7/8' 7/8' 6 9/16• 24 11/16• 9 1/6' 5/16' 3' 1 2 15/16' 518• 16• 15 1/2' 12 3/4' 1909 2169 32 3/16' X 32 3/16' X 30 5/8' MOTES: 4ij X-TES 1. ALLOW 30'CLEARANCE TO SERVICE SIDE OF UNIT, = 48'ABOVE UNIT, 6'ON ONE SIDE, 12.OM REMAINING SIDE, 0 NO AND 24'BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPEAATIN6 AMBIENT IN COOLING MODE IS 5rF, MAX. 125rF. 3. SERIES DESIGNATION I3 THE 14TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY�. A So. M AIR IN AIR AIR DISCHARGE DISCHARGE � f I G A FIELD PO;R SUPPLY CONM. 7/8' HOLE WITH $1 1I8'KNOCKOUT AND 9 1 3/8' NNOCNOUi AIR IN-� FIELD CONTROL SUPPLY CONN UP E B . F FAIR IN • N 3/8 LIQUID LINE000NN. O P / D E J C 3 I/2' • • 1 7/8• L 3/8'TIEDOWM KNOCKOUTS D VAPOR LINE CONK. H l2)PLACES K L i\---o MITI" AIR IN UNIT SIM MCU M PAD DR6F]V MS 18.24.30.36 23 112' X 23 1/2' 26• X 26' 42,48.60 31 1/2' X 31 1/2' 35, X$5, Load Short Form Job. wrightsoft4 Date: Jun 17,2017 Entire House By: Nutmeg Mechanical Services Inc. 130-3 Utopia Road, Manchester,Ct 06042 Phone:860-643-2042 Fax:860-643-1753 Email: steve@nutmegmechanical.com Web:www.nutmegmechanical.com Project • • For: Jacques Construction LLC 10 Gilbert Lane, South Windsor, CT 06074 Design Information Htg Clg Infiltration Outside db('F) 7 88 Method Simplified Inside db (°F) 70 75 Construction quality Semi-tight Design TD ('F) 63 13 Fireplaces 1 (Average) Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/lb) 48 26 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Payne Trade Trade PAYNE HEATING AND COOLING Model Cond PA13PA048****B AHRI ref Coil CNPV*6124AL*+PG95XA*60100C*** AHRI ref 6432880 Efficiency 80AFUE Efficiency 11.5 EER, 14 SEER Heating input 0 Btuh Sensible cooling 32550 Btuh Heating output 0 Btuh Latent cooling 13950 Btuh Temperature rise 0 °F Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.025 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 0.92 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft") (Btuh) (Btuh) (cfm) (cfm) first p 3341 37363 21262 918 972 second p 1415 25719 17726 632 810 Entire House d 4756 63082 33488 1550 1550 Other equip loads 0 0 Equip. @ 0.93 RSM 31211 Latent cooling 2862 TOTALS 4756 63082 34073 1550 1550 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" Right-Suite®Universal 2017 17.0.23 RSU12941 2017-Aug-03 12:02:23 Page 1 .4CGi N:\Jacques 10 gilbert.rup Calc=MJB Front Door faces: N Load Short Form Job: wrightsoft Date: Jun 17,2017 firs t By: Nutmeg Mechanical Services Inc. 130-3 Utopia Road, Manchester, Ct 06042 Phone: 860-643-2042 Fax:860-643-1753 Email:steve@nutmegmechanical.com Web www.nutmegmechanical com Project • • For: Jacques Construction LLC 10 Gilbert Lane, South Windsor, CT 06074 Design Information Htg Clg Infiltration Outside db(7) 7 88 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD ('F) 63 13 Fireplaces 1 (Semi-tight) Daily range - M Inside humidity (%) 50 50 Moisture difference (gr/lb) 48 26 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AH R I ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) living 187 3739 2618 92 120 family room 340 5182 4268 127 195 foyer 180 1567 564 39 26 entry closet 14 0 0 0 0 dining room 163 1902 1582 47 72 coat closet 6 0 0 0 0 laundry 30 961 546 24 25 mud room 89 1233 161 30 7 dinette 117 1662 2074 41 95 kitchen 200 1017 540 25 25 1/2 bath 30 473 316 12 14 broom 9 0 0 0 0 closet 2 18 0 0 0 0 guest suite 210 4410 2733 108 125 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .` Wrl htSOW 2017-Aug-0312:02:23 9 Right-Suite®Universal 2017 17.0.23 RSU12941 ACCA N:\jacques 10 giibert.rup Calc=MA Front Door faces: N Page 2 guest bath 81 1630 738 40 34 • guest closet 54 1035 181 25 8 main basement 1408 10318 2956 254 135 upperfoyer 180 2234 1984 55 91 pantry 25 0 0 0 0 first p 3341 37363 21262 918 972 Other equip loads 0 0 Equip. @ 0.93 RSM 19816 Latent cooling 778 TOTALS 3341 37363 20594 918 972 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .` ft�ht I WPso 9 Right-Suite®Universal 2017 17.0.23 RSU12941 2017-Aug-0312:02:23 �� NAjacques 10 gilbert.rup Calc=MJ8 Front Door faces: N Page 3 Load Short Form Job: + wrightsoft` Date: Jun 17,2017 second BY: Nutmeg Mechanical Services Inc. 130-3 Utopia Road, Manchester, Ct 06042 Phone 860-643.2042 Fax:860-643-1753 Email. steve@nutmegmechanical.com Web www.nutmegmechanical.com Project • • For: Jacques Construction LLC 10 Gilbert Lane, South Windsor, CT 06074 Design Information Htg Clg Infiltration Outside db ('F) 7 88 Method Simplified Inside db ('F) 70 75 Construction quality Semi-tight Design TD (°F) 63 13 Fireplaces 0 Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/lb) 48 26 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AH RI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) master bed 307 6154 4451 151 203 master bath 154 3942 2333 97 107 wic 110 1217 294 30 13 bed 4 120 2522 2821 62 129 bed 4 closet 12 0 0 0 0 full bath 81 1604 1118 39 51 bedroom 2 183 3376 2788 83 127 bedroom 3 169 2984 2593 73 118 hall 136 0 0 0 0 bed 2 wic 77 2078 382 51 17 bed 3 bath 66 1842 947 45 43 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wrI ht50ft' 2017-Aug-0312:02:23 9 Right-Suite®Universal 2017 17.0.23 RSU12941 ACCP, N:\jacques 10 gilbert.rup Calc=MJ8 Front Door faces: N Page 4 • • second p 1415 25719 17726 632 810 Other equip loads 0 0 Equip. @ 0.93 RSM 16521 Latent cooling 2085 TOTALS 1415 25719 18605 632 810 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft• 2017-Aug-0312:02:23 9 Right-Buda®Universal 2017 17.0.23 RSU12941 t7�iC11 N:\jacques 10 gilbeR.rup Calc=MJ8 Front Door faces: N Page 5 SITE COMPLIANCE CHECKLIST TOWN OF SOUTH WINDSOR,CONNECTICUT ***** FOR C OF O***** ADDRESS _fQ K/ �9� L AP _LOT/UNIT# cJ Reviewed by �� (Engineering) CONTACT/DEV ) c) in J Q 1 J 2 S Date Reviewed 1 °l !am ed/Denied PH#_ .9(06 30.5- 6 Reviewed bvlf/ f/4 d (Planning) Date Submitted I - ` � _ Date Reviewed- gr /Denied Date Reviewed —,Approved/Denied(Health) As required in the Zoning and/or Subdivision Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan r V/ 2. Finish grading per approved building permit plan e� 3. Site work, i.e.trees,shrubs, dumpsters,required parking 4. Utility location; a. sanitary sewer/septic systems b. foundation drain ►T`� C. electrical&telephone _ d. water e. other--GAs S. Sewer connection charge paid e./77� 6. Appropriate certification �� 7. Bonding 8. Planning&Zoning/ Inland Wetlands Considerations a. Lighting b. Signage Freestanding Wall C. Fee in lieu of Open Space COMMENTS: &12nCj s/engineering/molloy/site compliance checklist SITE COMPLIANCE CHECKLIST TOWN OF SOUTH WINDSOR,CONNECTICUTI::] *****BUILDING PERMIT***** ADDRESS �'�. ►I�?2 "a n-e__ LOT/UNIT# 3 Reviewed by n (Engineering) CONTACT/DEV� )LLC4L P�S Con S4n,t Date Reviewed ' 3 "� pproved/Denied Reviewed by. ( � (Planning) Date Submitted /ail Date Reviewed /Denied Reviewed by (Health Dept) Date Reviewed Approved/Denied Ih accordance with the Zoning and/or Subdivision Regulations,prior to the building of any structure on a lot,a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name,address&phone number of owner/applicant 2. Name,address&phone number of plan / preparer ' 3. Zoning Information—i.e.zone,open space, / floodway,street address 4. Plot Plan at 1"_40'scale a. Subdivision reference,abutting properties,.etc. b. Easements of record C. Lot description,bearings,building lines, distances,area,etc. d. Contours,adsting&proposed,1 Or 2ft.interval where appropriate e. Building locapon with dimensions.Elevations of proposed finish floor,garage floor¢erline / of road at driveway f. Elevations of gravity drainage systems,sanitary &foundation drain at the house and the street g, Tentative utility location(gas,water,electric, septic system,etc. h. Title block with name&address of preparer, date,appropriate*certification,live seal&live signature consistent with the Board of. Registration requirements.(P.E.&LS.) S. Sedimentation and erosion control 6— Special Planning&Zoning;Inland/Wetlands considerations(Plans-on file w/Town Clerk) COMMENTS' 7�S7 Z.cc A A f /1 C 0- 44 Q -t s/engineering/molloy/buiiding compliance checklist ZONING COMPLIANCE FOR SMALL STRUCTURES (Sheds and detached decks 200 sq. ft. and smaller) pM..0 S �O Address of Proposed Structure: 1 L� 1►1 b 'IL B Zone: ab Name of Owner: aiQ Fa SWG -Armor ti ISIS PIN: Phone Number: -191 - 21 C, -0 Application #: .Z $ D 0-76-9' 1. Name of Applicant: Re-, CO'S c Address: GW6-f�-- c i_ C�607t- Phone Number: gbC 8 - 216 CD RECEIVED 2. Structure cannot exceed 200 square feet. MAY 2 4 2018 TYPE OF STRUCTURE: SHED DECK (not to exceed 30"from NDSM PLANNING DEPT. DIMENSIONS OF PROPOSED STRUCTURE: 3. A Class D survey must be submitted with the application showing the property lines, all other buildings and the location of the proposed structure. 4. Is the property served by a septic system? Yes No If yes, the applicant must complete and submit a B100a Application to the Health Department for review and approval. The undersigned hereby permits Town staff to enter onto and inspect this property during reasonable hours for the purpose of reviewing this application and to determine final compliance once construction is completed. I, the undersigned, acknowledge that the above information is true to the best of my knowledge and that the above requirements are un ers ood Applicant Signature: Date: 2-Q. Owner Signature: SQm e-- Date: ***************************************************************** Reviewed and approved by: Date: 5W i 3 Zoning triforcement Officer Reviewed and approved by: Date: Environmental Health Officer cc: Assessor Building File -qCANNED 04/15/14 VW i /g `L 9 ` � t t W c y � �nG •° �^ a •• 0 xo Y SEVER.L Y J WOLF o rA LEGEND RECEIVED V^L. 13�2 PAGE 259 c e SITE g ° EID _• STING DESCRIPTION ON R DOMESTIC WATER -�' / j= 0 C y --- ---i- WATER MAIN MAY 2 4 2018 N22;38'35"E �! WATER SERVICE •r © WATER VALVE 110.00' / i y a FIRE HYDRANT SOUTH WINDSOR PLANNING DEPT. rlID2VH� LIGHTING 4 POLE MOUNTED LIGHT i =1i;5 NATURAL GAS t LOCATION PLAN ---4---�._ GAS MAIN , CZa r-1000• Ij S i3i }FtL i{ _--q,---..- GAS SERVICE LINE l3 •tEe+E 3iiiS POWER 9% ELECTRICAL LINES•OVERHEAD Y L ELECTRICAL LINES UNDERGROUNDUTILITY POLEPROPERTYPROPERTY LINE - - - - - EASEMENT LINE / SM245.52 Tf-•24,�37 o O IRON PIPE / 50' R.Y. 'IN N 240.38 (SE) v o • IRON ROD TO RE SET / /NV 235.7 -1 o „ O IRON ROD o MONUMENT I ` ' Nz 1 MONUMENT TO BE SET :2N ROADS N/F 6 LOT� / 4 OR SIGN ✓EFFREY D. & /ss+/I �• 6 GILBERT SITE FEATURES _ MICHELLE A. MARTONE 43+� X/ #f0 GILBERT LANE , # CHAIN K IDOL 1109 PAGE 193 "FENCE / Plt�i = V)TREE /;,6 r� / sue' .(T .1��j I. l C E ep l-Il TREE LINE OLO Oj�• / 1'01" SANITARY SEWER x SANITARY SEWER MAIN p A [O���C, 4---•.- SANITARY SEWER SERVICE LINE x 2¢V' G/.Lys• ` • NO 7r.Fi W ® SANITARY SEWER MANHOLE N f �a. 6 \ pi :�I • 1. PROPERTY/S/N THE AA-JO ZONE, ¢.6„ Z ?4g ^ 2. PARCEL CONTAINS 39,647f SQUARE FEET OR 0.910 ACRES STORM SEWER / ,� �� 3 O ^ I J HOR/ZOVTAL CIA7UM/S BASED OV NAD27. V£R77CAL DATUM/S BASED ON Q Z Z ---------- STORM DRAW PIPE 228• NAVD29. {`� N (0 4. PROPERTY DOES NOT FALL WITHIN THE L/Ml7S OF A FLOOD HAZARD ZONE r O ® STORM DRAIN MANHOLE DEC,L fn (7 AS[kP/C7ED OV.• 'FIRM FLOOD INSURANCE RATE MAP NUMBER -�0 p uTGI BASIN / H o CURB INLET >�- N I• PA�3BJ OF 675 COM OF MUNITY TY NUMBER D9y0036nEFFECT?W CLIT DATE*ORD COUNTY W N F-Z 247. 50.7 sEP7EMBER 26, 2008 FEDERAL EMERGENCY MANAG�vnfr AGENCY / U TOPOGRAPHY / ti 44.4` /NV 247.91 S9' FEDERAL/NSURANLE ADM/N/STRAVON, J d -----r----- CONTOUR O / \EXIST. HOUSE 5� LOCA NON OFU7K/nES DEP/C7ED HEREON WERE BASED ON/NFORMA77ON i •I PROVIDED BY CONTRACTOR „nw svor ELEVATION .Gj FF=253.08 \•� x 6. UNDERGROUND U77LITY, S7RUCTURE AND FACILITY LOCAnOVS DEPICTED WETLANDS Am NOTED HEREON HA bE BEEN COMPILED, IN PART, FROM RECORD 6' /WETLANDS LINE T.0.W.=251.90 w, ' MAPPING SUPPUED BY THE R£SPEC77W UTILITY COMPANIES OR GAR. FLOOR=251.09 °� Q GOVERNMENTAL AGENDEES FROM PAROL 7ESnMONY AND FROM OTHER SOURCES THESE LOC477ON5 MUST BE CONSIDERED AS APPROXIMATE/N ADDITF VALL W W NA 0 �_ TUE. Y, OTHER SUCH FEATURES MAY EXIST ON THE Sl7E, p /� 1S5• 0 6.01 \ \ 7NE EXISTENCE OF;W//Cl/ARE UNKNOWN TO DESIGN PROFESSIONAL$ INN.••. ii Nn 75.5• 12.0•+ .� \ THE ma,LOCAnOV AND EX/sTENCE O''ALL SUCH FEATURES MUST BE Z f7ELD DETERMINED AND VER/RED BY IRE APPROPR/AIF AUTHOR/nES l - 50%F.Y. I �, PO CN 13.4' p h PRIOR 70 CON57RUC770N M o' 7. COWRAC7a7 SHALL CONTACT GILL BEFORE YOU D/G'FOR co)UNDERGROUND U77U7Y MARKING AT LEAST 7iW7 FULL WQRK/NG DAYS PRIOR TD START Or CON57RUCnOV.• f-Boo-922-4455 OR ry�� CO C. WAL K y OPL ►nvx cBTv caFL � .� N24 5745"E _ +� 143.82' /.R. N I \ -1-251 - - - - ib .SS�E;fER PROPOS I •QASEM N ^ STREET TREE PROPOSED �WRSOURC'� ,250 EASEMENT EASEMENT 1 `" �'so �� i efaeaEs�RENc£s I ' c'> is p� tG 1. SUNSET HILL ESTA7ES R£SUBD/NSION 377 DEMING S7REET SOUTH IHNOSOR, CONNECnCUT RESUBD/NSION PLAN PREPARED FOR ACQUES CONSTRUCTION LLC DATED.• f1/9/16 REVISED TO 31712017(SHEETS 1-17)BY DESIGN Lu 1 2. APH/C SURVEY JACIX/£S CONSIRUCnOY PREPARED ..�....=....-...- - T lY ............ ........................ - .41 £S CDWS7RUCnON LLC DATED O8 6 SCAL E 1 40 fCR CW �� ........ .......... .. ........ ......;............�.......... ..................,............... ......... ...:._....�.............. ................ .......... ................. ................ .,.::. 57rE£7S V 1 d' V 2 BY DESIGN fNTOFESs/ .. .:... .. ............: .........:.............................. .,........ ........................L'v.............................. .. '.'.',;::.':.'.':.'.'.':.:{.':.' .'.'::':.'.'.':.'.'.'::.':.:'. :,,:: :::. .:':::::'::. :::::':::.'.':.' .7. EASEMENT MAP FILE NO• E7048 COIMP/LAnaV PLAN MAP SHOWING 348.57 ................ ... . . ' .. :o;.' ... ......... 1`49........... :.........�_... _. fASEMENr AREA 70 BE GRANTED 70 THE camiciTCUT LIGHT AND PoW£R '. :.'.':. :.'.'.'.'.':.'.'..'.':..:.'.'.':..'.'.':.... .......................... ........................ ....... ......... .. . .. ':.�':.�.' COMPANY OBA£V£RSa/RCE ENERGY ACROSS THE PROPERTY ✓ACOUES '.:.:.'.:.'.' .':.:.':.'....'.'.'.'.'::.':::.'.'.'.:.'..:......................... ............... .......... ... S2238'35' :::.:::.............. .......... ":.... ...................... •`. ......................... ................................. .......... ............... ..... CONS7RUCnON LLC GILBERT LANE SOUTH iWNDSOR, COVNEC77CVT ........................... ............. ........................................................ .......... . ..... ....... .......\'.'.'.'.':.:'.'.'::.':.':.'.'.'.'::.'.'.':: .'.'.'.'.'.'.'.'.'.':.':::.'.:'. ........................... "1':'.':.':.'.':.' .......... ................................. .......... ...................... .............::' ...:.: :'.'.'.'. .:^.':.. ....: ........... ........ ... ................................. PREPARED FOR JAOr!I/ES CON57RUC7OV DATED.- 41517 SCALE. f-30 ........... ........................ .....................\....'.:':: .':.'.:':.:'.:' OfE'SSTONALS INC 2 ............... ......... ................................. ... ................................ . .. - - - - - - - - _ _ SURVEY N07ES ? - - - ............ .............. .......... ................ ........................................... ...... ...................... .......... ................IJ................... ............. .... 9;:'::::.'::::::.•.•:::::.'.•:::::.•::::::.•.' .... .. ... .. ... ...................... ............................................. ............................... ........ MAP HAS PREPARED AN7 7H ................................. ................ ................................... ..... .... ... ... .. .... .�. ... .................................................................. ....... 1. THIS S(/RV£Y AND s BEfN PUR57/ n7 E h' .'.'.....'....'..rBlNdLti':.'::.'.':.'::.'.' .'.'.: ..:::.....-. r r A -1 eN...................... .............................. 1. ........................ ... . . .... .... . .. ............................... ................................... ....... ya")7avS OF C0VAfC7KU s AIE GENpES SECTIONS 20 30A6 f.......................x..... I I.I�, �,L., .. .. ............ .... ... . .................................. ................................... ........ _ V•.....................:............................... 'C(J(U .........x.. .....�........... ...... ...... IHRU 20-.T006 ?o AND THE S'rAl1N0AROs FCi4 suRV£YS AND MAPS M h'vsE- ............ . .............�--::: -�- ....•:.':.'.':..::.•.:'.'.•.-.x.'.':.':.'.':.:::'. :'.'.'::::.'.'..'.'::::.'-.,-'..r........ ............x... ...........•.........'.•.•....'*............ ...� 7NE STATE Or cOVNECnCl/T•AS ADOPTED BY 71C CLWACCnCUT :' :::'::':: :: :: :: .....::::::::..':..:..:...'::.:::..................� ........ ,. ................ ..... ...................... ........................ ........... ::::x::::: H Q .................. ..............................Sl... ............................................ ....... 49.......................... ..I.I_'.'.'.::'.'.'.' ............N- ........................ ............................................ ASSOO•AnOV OF LAND SUR DNS;WC CN SEPIEMBER 26, 1998.. ............ ...............................-.. .............................................• ...../... Z ......... ..................` ............' ............................ I .........................�...........................o......: - ::: ::..:.:.p.:............... ................... ............................... .. ............................................. ... ..................'�.. ............................Vp..........�.............. ............ ............. ........................ ...... .... ...':.'..:. ...:........... �. ...................�..........-..- ..-. ...�.�..... . 9....................... �....___,i•.._. ...:...::. ...':::::.'}°':'.::•::.:•.•:.:•:.•:.•.•.:•.•:.•:h':::::.':::::....:...........Q:::. TYPE A�Sf/Rt£Y/s AN/AIPROYEIIENr LOCAPON SURVEY- C) .. ............................................. �...... ? .................. •: .. .: :--":::-=...::::fix. ---.'!+1.. - ': :w,.'-::-:.-.wx. _ -An+D/s/N7EHLI�D Ta DEP/cr n�LacAnav a 0 W , ............ G .................... .. ................ 6NPROV£MEN7S mE>n PRO°ERIY LINES W r ........................... ....�.............................. .....fix............... .. .--:.- '... ... „5�.. .. .. :::.................. .T.. . -..-. :: : :: : .,, . .. .... ..... . .... RE[A ........... s................ ......... TINS/S A REDMVEY BASED OV MAPS REFMNCED NEREW . x:.'. V W }:'..'...'.'....'.'. .'.....'.' ...........:............................. _. . : .'._.'.GONG':':wa .:':':::::. : :.'.::':. :.-::::::::: HOR?OVTAL ACCURACY MEM CLASS A-2 STANDARDS VERncAt O > y .. AAWCAL ....... ....•;........................................:........ ,............... .......;�... .. '' ACIXIRICY MEETS CLASS ice?STANDARDS 7GM=OCJPcc .... ..........................................,c................:............ ............_. 250 ..:;':... .::.':..v .. ;< ACCURACY MEETS MAST T-2 s7A S ....... ..................... ...........,.............. I............. . '.;:;::::::.' 2 :... ......... ...... `b: . . ot SAN MH: 50' RIGHT-OF-WAY & 241.59 EASEMENT FOR ACCESS N� IN ( 229.66 AND UTILIT/ES ��` r gs BEI�ERL Y J. WOLF IN (S 229.74 EE VOL. 11 -VQL_1342 PAGSE 259 Ili l4 4� s PROPOSED s x - - sx- - s,-- -ANN-Ms,dACQUFS S �j STORM DRAINAGE !� < �J LEGEND VOL. 1286 PAGE 222 x r/% � sx�ASEM�1T s,- � SITE � g_ - - p E%ITER DESCRIPTION •� r< oouesnc WATER A 3905 I $ _ WATER MAIN WATER SERVICE a / \ / --. _ ` �� �� / $ •H w r 1 © WATER VALVE 5 E N22:38 35 E AA FIRE HYDRANT (� I. / ,175.00' LIGHTING } # POLE MOUNTED LIGHT OWE = f 'Ito _ /\ 1� S NATURAL GAS �• �--- Il '�-'- LOCATION PLAN i�- {' f i' 4---4- GAS MAIN \ • • •\\ % •- • _. /I // x . • •\ 1,-1000 �L _• { p� CAS SERVICE LINE �j� ` 14 {°jE POWER \ �k V) / //•// ��' �- \\ F E !S if L'F 01 ELECTRICAL LINES.OVERHEAD �} \ r / h - - - - - ,- I/• - ,. \ \ 1`5 9j g• fill ELECTRICAL LWES,UNDERGROUND 1 I. I I I 1 •- 'l •\\\� •'. < < �g • ^'l iF FY'U. UTILITY POLE �1; •�I PROPERTY �L( � • I 1• ` lNt!:239.5 PROPERTY LINE -- �� ~ •II •1 � 4! d6i� \ PROPOSED DB - - EASEMENT LINE -y� 1\ \ \' \. TF° •41.54*3 o IRON PPE \ \ \ \ w \STORM AND • IRON ROD TO BE SET X ' '� \\ A- SAN. SEWER •15" CPP 234.60 J 0 o IRON ROD g o0 EASEMENT E" PENING 2a37.2)\\ °0, m 0 MONUMENT / -"- - - \ N \� \ \ \ A NTO OPENING Ag9.09' 1 2 o N ■ MONUMENT TO BE SET / I •\ •\ N v N07E5. � `o-v I be In ROADS / / �'�"•7T :Q ti \\ \ \\ \ \ =_ _ I \ t 1. PROPERTY/S/N 7HE AA-30 ZONE. V c O v OR �� SIGN / N I \ - \ -'_ i \ \ _ �. = / I l /, 2. PARCEL CONTAINS 36.1BOf SQUARE FEET OR 0.831 ACRES o�3 m SITE FEATURES _ _ �►-- \ \ ` •`�f��1 = \' / 3 HORIZONTAL DA 7UM IS BASED ON NAD27 VERACAL DA 7UM/S BASED ONNA W29. 7 ••• EDGE OF WATER s`r- / L I I• x \ `7�y�_ \• /• 'l l•/ I 4. PROPERTY DOES NOT FALL W1TH/N THE LIM17S OF A FLOOD HAZARD ZONE e •-•-• •- CHAIN LINK FENCE / a tu• `�� �' /, :/ AS DEP/CTED CW. FIRM FLOOD INSURANCE RATE MAP NUMBER ® • TREE p P1rI/ / " I rn - 4. �• ` �• �� - - '/'�- / 09003CO383F TOW OF SOU7H WINDSOR CONNECNCUT HARTFORD COUNTY g t t N ter, -�,, J /� PANEL 383 OF 675 COMMUNITY NUMBER 090036 EFFECNV£DATE• p$ /1-Mr�I-YYM TREE LINE / O,ML/ I• S _�� - - - - - �� �1 + _ SEPTEMBER 26, 2008 FEDERAL EMERGENCY MANAGEMENT AGENCY SANITARY SEWER - FEDERAL INSURANCE ADMIN/SMA770N. SANITARY SEWER MAIN / P Q \ •+-I- 1 > ti O "L""'.X- \ /� ! 5. PARCEL HAS THE RIGHT TO DRAIN ONTO PROPERTY TO THE SOUTH SEE Ur ,,Ip/ �I• al ^ \ .�� - - - --� VOLUME 923 PAGE 238 ---a--->ti- SANITARY SEWER SERVCE LINE 11'"' \ DECK O cb \ U/ ti � ��'- �. �- ^"�� 6. UNDERGROUND UTILITY, STRUCTURE AND FACILITY LOCO NONS DEP/C1E0 W 0 SANITARY SEWER MANHOLE .� � O a�•I I I 4>�-�(� II�: tV / AND N07ED HEREON HAVE BEEN COMPILED, /N PART, FROM RECORD STORM SEWER % 6 \ Ii S may) r� 9.9•N ?� , ` \�'' �• �� !C� Cy / MAPPING SUPPLIED BY THE RESPECNV£U77LITY COMPANIES OR STORM DRAIN PIPE % + � o #10.5 H -J [11f,� \ (� ` GOVERNMENTAL AGENCIES FROM PARLK 7FSRMaJY AND FROM OTHER ` Z w V ---- ® ---- STORM DRAIN MANHOLE ?49`T •\ �I •� \ �R) ?g> 5.7' SB"o 98' :�� !� _ \ pj , \1 NAUIURERC,S ADO nLWAY,n07HER SUCH FERONS MUST BE ESRMAY EX/STED AS RON/THE SITE, � Q Q V 0 CURB INLET N l 'sk O N q ._�� \ \ 7HE EX/S7ENC£OF WHICH ARE UNKNOWN TO DESIGN PR(P£SSIONAL.S; INC. '/� Z O CATCH BASIN p (�7) I T Z 13B' o ^ A�G #6 G/LBER ANE \ (p \ \ ID[\1;ec` THE SIZE, LOCA77ON AND EXIS7ENCE OF ALL SUCH FEA7URES MUST BE W V/ Z / FIELD DETERMINED AND VfR/F/ED BY THE APPROPRIATE AU7HAP/NES w O TOPOGRAPHY N I� I 1 1 _ _ \ PR/OR TO CONS7RUCnCN ' m V 1 _ - �" 7. CONTRACTOR SHALL CONTACT'CALL BEFORE YOU DIG'FOR J__--_p----- CONTOUR 50.7 � \ � Uo: UNDERGROUND U77LITY MARKING AT LEAST TWt7 FULL *MK/NG DAYS J Q O ><" SPOT ELEVATION I • , . I I EXIST. HOUSE 16.3' S80' \ �� PR/OR TO START OF'CONS7RUC77CW- 1-800-922-4455 OR y WETLANDS \ x _ p - _ FF=253.81 I , WWW.C8YD.CON = m N z WETLANDS LINE I T O.W.=252.60 ..3 GAR. FLOOR=251.62 x I I OT N F c *� �� B�T. DRI VE \x ( � N ui ° 133" b X MAP REFERENCES. 0 * I 14 VLBERT LANE \ to I 0 ti 14.8•N p ' 1. SUNSET HILL ESTATES RESUBDINSICN 377 DEMING STREET SOUTH WINDSOK; Z CONNEC77CUT RESUB011651ON PLAN PREPARED FOR✓ACQUES CCN57RUC710N, %, I } N� by U LLC DA 7E0.- 1119116 REVISED TO J1712017(SHEETS 1-17)BY DESIGN '/� \ PROFESSIONALS INC. N 5 aD 010.0"00 10.3 h F Y 2 PROPERTY& TOPOGRAPHIC SURVEY✓ACQUES CON57RUC77ON PREPARED _ FOR.- ✓ACQUES CONSTRUC770N• LLC DATED 08109116 SCALE 1"-40' tj 1G ROPO _ 3 xl\ I SHEETS V-1& V-2 BY DESIGN PRCIESS/GNALS INC r + J. EASEMENT MAP FILE NO.* E7048 COMPILA77ON PLAN MAP SHOWING ' roRM r D x PA VE WALK I EASEMENT AREA TO BE GRANTED TO THE CONNEC77CUT LIGHT AND POWER p' �,T {k►E I \ TEMPORARY COMPANY OBA EYFRSOURCE ENERGY ACROSS THE PROPERTY OF✓ACQUES CO1VS7RUCNON LLC GILBERT LANE SOUTH FWNDSOR, CONNEC77CUT SE/NEAf tI x I I CONS7RUC170N PREPARED FOR✓ACQUES CONSTRUC77ON DATED: 4/25/17 SCALE. 1"-JO' h� 4,J} I `� N K / EASEMENT BY DESIGN PROFESSIONALS INC to X 4. EASEMENT MAP FILE NO." E8029 COMP/LA 770VV PLAN MAP SHOWING V 2588 EASEMENT AREA TO BE GRANTED TO YANKEE GAS SERVICES OBA 0 p P E 36 EVERSOURCE ENERGY ACROSS THE PROPERTY OF✓ACOUES CONS 7RUCNCN LLC GILBERT LANE SOUTH WINDSOR, CONNEC7ICUT PREPARED FOR✓ACQUES CCM97RUCRON DATED: 41512078 SCALE: 1'=30'BY DESIGN pp PROFESSIONALS INC. P k k k k I 'k k k PRl'3POED-�k k k p k k 5 IMPROVEMENT LOCATION SURVEY-RECORD SUNSET HILL ESTATES GILBERT o k k SjREE TREE k� k k k W k k k k k LANE AND LOOM/S ROAD SOUTH FWNDSOR, CT SCALE: 1' 40'DA7E.- g k 09/08/17 RENSED TO 1111412017 DESIGN PROFESSIONAL$ INC. e k k k Ar k :kASEMEN`T k / k -'k k k k_ x Y k k 75 00' k k 1 k g ! E{�ERSOURC GAS / y4 F - S22 38 35"W n "L AJ�EMEI I�-"-'. I ,J� SVRWY NOI£S, t``�1 -' 1 Y AP HAS BEEN PREPARED PURSUANT TO THE_ - -- IH/S SURV£ AND M A ED PUR g -T -y-- _ - - - - - -, - REGULA77ONS OF CONNEC77CUT STA7F AGENCIES S£C770IS 20-30015-I y._ _ - "'- .ER•SVC�[ft,E ZR '^ 7HRU 20-3001-20 AND THE STANDARDS FOR SURVEYS AND MAPS/N Q x 1 .� ENT IHE STALE OF CONN£CTICUT'AS A9OPIED BY THE CONN£C77CUT L. L012 ... 177" Ix ASSOC/A lI01V Li�LAND SURVEYORS INC ON SEPTLIIBER 26, 1996 .� W / .... ... .-..... - ... .. - - N - O S - 5 .., ...,.. .:.�.. R 1 x�T 71PE 0�SURVEY/S AN U/PROV£MENT LC�ARON ,. .�. �.- .... ... ...o IW. _ ...�.� � .�. .�.-.'.� - -..�.� ..- tv�:� :' WENDED DEPICT THE LOCO ROW OF Z W � X:- .. .........Vic...... ..�-" -........ .. _.,o._. .- .... ...�. IMPROVEMENTS RELA 77V£TOO PROPERTY LINES F� ... N '� THIS/S A RESURVEY BASED ; a / 6% :6x- I .�z �".:� .�.0•iI-�'- �257_-•Gx - _ -�...� '!�^- r �I--T GV MAPS REFERENCED H£RECW. O s .. HORIZGVTAL ACCURACY MEETS LASS A-2 STANDARDS WR77CAL CC O ; U q ACCURACY MEETS CLASS V-2 STANDARDS TOPOGRAPHICAL a J �a V ACCURACY MEETS CLASS T-2 STANOARDS SCALE: 0 15, 30' 60' N TO MY NO EDGE AND BELIEF THIS MAP IS SVBSTANRALLY CORRECT AS NOTED $ 1' - 30' HERE SHEET u A„t,��y 377 V-1 LAWRENCE R C£LSS1 R, AR,L.S r SOO-VVj vANDSOR ENGINEER DEP" 'lea. 4' vo -0 0, m`° o i LEGEND x ��� o SEDIMENTATION AND EROSION CONTROL N wmU-N N C '' IRON PIN TO BE SET o O�� � H w 0 N N V o MONUMENT TO BE SET �� !y:/F 1. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE a N o o b Lo PROPOSED CATCH BASIN AND PIPE �N FEVEIcL.7" J. WUi.F "GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL" BY THE CONNECTICUT COUNCIL Viip // VOL 1342 PAGE' 251? � FOR SOIL AND WATER CONSERVATION. � � � z a -55-&55- PROPOSED SANITARY MANHOLE AND PIPE ��/ r 2. EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO 0 3 Q a `:� CONSTRUCTION, AND SHALL BE MAINTAINED OR REPLACED AS NECESSARY. ° V' 3 a o G PROP. GAS SERVICE _,ref/ s PROP. 6" SAN. LATERAL (S=2% MIN.) TF,244.5r N 3 CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTATION AND MAINTENANCE OF ALL o -- --- -- - - - - - `- - - - - - - -- SEDIMENTATION AND EROSION CONTROL MEASURES SHOWN ON THESE PLANS. ANY y ae a EU PROP. UG ELECTRIC 8c COMMUNICATION SERVICES t PROPOSED CHANGES TO THIS PLAN MUST BE APPROVED BY THE ENGINEER AND/OR THE wwj Ns- PROP. WATER SERVICE l� TOWN OF SOUTH WINDSOR. � �H PROP. 6" PVC FND. DRAIN (S=1.0% MIN.) 4. CONSTRUCTION ENTRANCE SHALL BE INSPECTED REGULARLY. STONE SHALL BE ADDED � O W>. -84 - EXISTING CONTOUR �XIST EXISTING ROADS ASLACED AS EDEEMED NECESSARY.QUIRED, AND ACTOR SHALL BE RESPONSIBLE FOR SWEEPING _ ■� LL a 84 PROPOSED CONTOUR - - -.-.... - -- `� -x 'x x Sx -- --- x c x '""'- "_ `" = - �., -----. 5. AREAS TO BE LEFT BARE FOR MORE THAN 15 DAYS SHALL BE TREATED WITH AIR �o �� y ti X 195.6 PROPOSED SPOT GRADE -- -- -__ - . ____ ___ `� ` x �x + a' DRIED WOOD CHIP MULCH OR SEEDED WITH PERENNIAL RYE-GRASS, UNTIL FINAL GRADING -_--------- AND STABILIZATION EFFORTS TAKE PLACE. No TREE STUMPS SHALL BE BURIED ON THE 5F PROPOSED SILT FENCE _ _ PROPERTY - EXISTING TREELINE ___ % TF:243.41 _ T FG 6. ADDITIONAL EROSION CONTROL MEASURES SHALL BE INSTALLED DURING CONSTRUCTION - - - - EASEMENT BOUNDARY / / GRADE TO DIRECT INV IN :240.25 15 "(SE) � - IF DEEMED NECESSARY OR ORDERED BY THE ENGINEER OR THE TOWN OF SOUTH WINDSOR. FLOW TO BASIN �INV OUT:240.25 15 (N) (TYPICAL) '� 7. YARD SHALL BE LOAMED, SEEDED, AND MULCHED WITH STRAW PRIOR TO ISSUANCE OF i/ / -- - _- -- - - CERTIFICATE OF OCCUPANCY. a Is Sf � -iiaa� - � SF 5F PERMANENT VEGETATION COVER / ACC/PROPOSED UTILITY `\ SEEDING DATES: APRIL 1ST TO JUNE 1ST & AUGUST 15TH TO SEPTEMBER h ° ESS DRIVE. REFER \ 15TH USE THE FOLLOWING MIXTURE: a TO DETAIL. (TYP) \ BLUEGRASS BLEND (3 VARIETIES) 50% g � 01 / f CHEWING RED FESCUE 30% g � EARTH OR _ PERENNIAL RYEGRASS 20% STONE ANCHOR \_y APPLY 4.50 POUNDS PER 1,000 SFy � PILE ` �� 11 - CB GRATE j P5`r RCP G? a � 2 f fi o E INv.'244.5© l ;' SMH1 X. TEMPORARY VEGETATIVE COVER �v �s Q� dg� FILTER FABRIC _ - / �� T.F.: 243.53 � /` INV IN:235.69 8" SE o• SEEDING DATES: MARCH 1ST TO JUNE 15TH & AUGUST 1TH To OCTOBER 15TH 12 INV IN:239.00 6" S ANNUAL RYEGRASS 100% APPLY ONE POUND PER 1,000 SF OR 40 POUNDS - r " PER ACRE WITH ANCHORED HAY MULCH AT 2 TONS PER ACRE. U 1 Tf=:246.85 INV OUT:235.69 8 NW J � SUBGRADE PROPOSED `� J � FILTER J SILT FENCE ---------- -- ------ ------ >✓ C SUBGRADE _I FABRIC i (TYPICAL) / ,�j0' Y• � - ! O 03 CM INV 239.00 O U = U 00 CB TOP I --� 4 / J, �.. - {(Qo 0 .a=, N L; /" % INV 240.00 W bO 0 N C ,,.. 90 LF of 6" SDR-35, s=3.so%�� DATA BLOCK LOT #3 U "- NOTE: " `~ %� - - -- - -- -- ._. I 1A [.`,11 RF'RT 1 ANF'd �l n %nn REMOVE CB GRATE. PLACE FILTER FABRIC. /' J %/ % J 6- PVC FOUNDATION DRAIN ur ■ ...■■-r r.■■ ■ ■ ■_ - ap REPLACE GRATE TAKING CARE NOT TO J / / DAMAGE FILTER FABRIC. ANCHOR y I sW ss ZONE: A A-3 0 o WITH STONE OR EARTH PILE. � // 0• CLEAN OUT - } � � USE: RESIDENTIAL ZONE N INV 242.50 g N l REQUIRED/ ITEM PROVIDED o ALLOWED z ; CATCH BASIN GRATE "J i/ /j _ - - -90 umc� - - - I N� �� Lot Area 30,000 SF MIN. 39,647 SF MIN. w � .. Z Z SEDIMENTATION CONTROL / o0 ` w m ,,.- � �� / �6 `\ � I `"'�- Lot Width 150 FT. 191.84 FT. a o 1 Lot Depth 150 FT. 209.99 FT. N.T.S. Front Yard 50 FT. 51.38 FT. J 1 F.250, / l i / 4 246 Rear Yard 50 FT. 107.61 FT. LLI lNii246.5I� r' F� `� r/ // s' Side Yard 20 FT. 43.76 FT. Lot Coverage 15% 11.32% MINES Building Height 2.5 Stories / 30 FT. 2 Stories a W 247 ( Z LLB a 1. SET POSTS AND EXCAVATE A 2. STAPLE GEOTEXIILE TO POST -�- J/�// / / / // \\ HOUSE ELEV. L 0 T 3 I N Z 6"x6" TRENCH UPGRADIENT OF � j` - J / �i ''" / pCISTING � � GAR 251.0 � ` \ W � O POSTS. _ TOO = 252.0 Q �` // / / / , '' ® TREE LINE TO I CF = 244.5 #10 GILBE LANE 52.58' I o STREET TREE EASEMENT / BE REMOVED _ m ANGLE POSTS m 5' UPGRADIENT , / � � i (SEE MAP REFERENCE 1) / I $� `�5��' `• i 248 MAP REFERENCE: J W C OST SILT FENCE °° J_ a) 95' _ I 1 . SUBDIVISION REFERENCE TAKEN FROM PLANS ENTITLED SUNSET HILL n 12" ELECTRIC DISTRIBUTION / I j N �� PROPOSED / + ` \ /--- J I TREE LINE / EASEMENT (SEE MAP ^ c - -=-- ---- ---- ------------ --- '" N ESTATES, 377 DEMING STREET, SOUTH WINDSOR, CONNECTICUT. Z (TYP) / �' \ REFERENCE 2) e PROPOSED I PREPARED FOR JACQUES CONSTRUCTION, LLC BY DESIGN �� /� �\ j, / �` GAS SERVICE I �- ' 249 PROFESSIONALS, INC., DATE: NOVEMBER 9, 2016 REV. TO: 03/07/17. W O - \ ( N w _ 1 - I APPROVAL APPLICATION 16-59P. N r = a _ __ A624'57'45"E l / 1 \ - ` _1 M 3. ATTACH GEOTEXTILE TO WOOD 4. BACKFILL TRENCH AND SF -/43.82'- `- i ISS- o PROPOSED - - 2. ELECTRIC DISTRIBUTION EASEMENT REFERENCE TAKEN FROM EASEMENT Z POSTS AND EXTEND INTO TRENCH. COMPACT EXCAVATED SOIL. / / 5F I WATER dh SERVICE I MAP ENTITLED COMPILATION PLAN, MAP SHOWING EASMENT AREA TO = O o 51.38' BE GRANTED TO THE CONNECTICUT LIGHT AND POWER COMPANY DBA N FILTER FABRIC 25� f i -_ J ,. 250 EVERSOURCE ENERGY ACROSS THE PROPERTY OF JACQUES 1I1 ^'m - - °` PROPOSED TEMPORARY-C- Al- - - -r- T g. CONSTRUCTION LLC, GILBERT LANE SOUTH WINDSOR, CONNECTICUT COMPACTED BACKFILL �d�. _ - k t _k ,�` INLET PROTECTION. REFER k k k k REPAIRED FOR JACQUES CONSTRUCTION, LLC BY DESIGN k1 k r _� -- = ' _ _}- k k k TO DETAILS ON EROSION / k k -k� k k k PROFESSIONALS, INC., DATE: APRIL 25, 2017. } _ k - _ -. ----- j ,X & SEDIMENTATION NOTES �_ k k 00 0 N k - & DETAILS SHEET. (TYP) M. k k r k k k k k k k k k Ok �, k �k 0 k �,k C' k k k � _ � k k I I- - k; �� k' k k k 348.57 SILT FENCE *: _. �_ 517 SF sr1835�w om L .,yam �' .-�. �- J V V _� 1=u � N.T.S. \ ,k - - .. .,E...' _._...... �_ - _ , J .r•!lrw�_ vsrs s seas ess-- / V.4- Y / 1- •® r O (V - s ♦<_, ,eao ��- ,... .. fl '� �kwi-tom..'-tt � X zo 71415 SURVEY AND l7AP NA5 BEEN PREPARED PURSUANT O NE I T N _ J-- >+rems • �cc vr.aaa*►svu S � 6eseo sesersss r♦®ssrarras.aN rses se .. �_. ��� _ REGULA T/OHS OF CONNECTICUT S TA TE AGENCIES SECTIO N s GILBERT LANE N o 1�-oo �� '�, ,?+� ,, a. _. -� � 20-3006-I TNRU 20-3006-20 AND THE STANDARDS FOR - o -- -- --= - r �� _ SURVEYS AND /TAPS /N THE STATE OF CONNECTICUT AS � R�.:,�ht r;yxr:cc�aaer,�a �•. ,.. ,n-e.sr et£ ';�':- -+-�. \-205.0'-8" SDR-3; ADOPTED BY THE CONNECTICUT ASSGL/ATION OF LAND Uj 248.6 2g 2S� / LU 2 2 m E 2 s @ 3.37% SURVEYORS, INC. ON 5EPTEl7BER 261 I996. a ry ,- W h U - 5 _ .---- -- W 5 - --- - W S - j�S -- r�- -- z - -- r v Q _.... ..___._ ______�_____._.. __._. .. . .__. __---._ _ __._ . ._......_ ___ :. -_.__ �_ ______:__ ___ _.____ --.__._----_-_--<- -------- __..__ - --- ---- - -- ---_ ----- TYPE OF SURVEY /S AN l/7PROVEl7ENT LOCATION SURVEY - �.. 2�9 e „ �� G- a c - G.- uNDERGRouND ELECTRIC & ---- PROP05-FD - AND 15 INTENDED TO DEPICT THE LOCH TION OF o -- ----- - -- -- ------ - ------ `� ---- COMMUNICATION SERVICES - ------- _____z a , ---a---- PROPOSED IMPROVEMENTS RELATIVE TO PROPERTY LINES a d a a s 1"w COORDINATE INSTALLATION ----- - 1. --- - -WITH APPLICABLE UTILITY ►- \ ��"" T �- k THIS /S A RESURVEY BASED ON /7AP REFERENCE #l. r/ k k• cv ®..r k , k k 1. 50 k COMPANIES) ,, k k \ik k , ) X k _ ! %d k { jl k k �. U Xa X {� 2 C� k X k1 k W k \ 1 k k 0 A- k k k 1. k i ,� � � � � � • NOR/ZONTAL ACCURACY /7EET5 CLASS A-2 STANDARDS AND VERTICAL � N k - � -- - -- - k k k k -- u� - "" f - Al "'"°"2` S5ACttCURACYDD MEETS CLASS V-2 TOPGYRAPN/C ACCURACY /7ETS CLASS T-2 p k k k k k k k ,'� k 252O MY hAT0? W,-5AND BEL/EF TN/S 11AP /S SUBSTANTIALLY CORRECT LO k k k k k k A, X k k k k _.. �. k k �} - Al A AZT, k kk -- k Z A122�835"E J o Jl68.58' N iJ�£�E' 12327 W v i ' I 252 I 25, `r'�� ,.._. .-- -- - - - - - - - - - - -- _ I, N LANRENCE R. GE/SSLER, JR., L.S. � L1C. NO. Z a � ( � __ I - r I I J I Q N M 17 i �'s I 50' F.Y. �- _ I ( I �/ INV= - - - I ._ - _ I O SENSE o J HOUSE ELEV. I ( I 245.00 I - - ���iiiiii�, 0 I I GAR = 253.0 / I I I x I `�� OF C O NNE' o Q / o I r TOC = 254.0 / , 9�G4 n 6 z i t nc i ��;-''rf3ER C�j�i ui o Q OWNER/APPLICANT: P 0 � N Jacques o Construction, LLC - C A ,� .' l Oe 67 Ridge Road ;-o'.�` 21;''; ;�� ` SHEET ° South Windsor, CT 06074 u 860-432-1823 T pp�l 201800019 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF OCCUPANCY DATE: 01/16/2018 ( 42 9( ooc) GIS ID:35300010 / FEE: 10.00 MUNIS APPLICATION# 201700619 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: JACQUES CONSTRUCTION ADDRESS: 10 GILBERT LANE ADDRESS: 67 RIDGE ROAD OWNER: JACQUES CONSTRUCTION SOUTH WINDSOR,CT 06074 67 RIDGE ROAD SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: NEW HOME. 3,199 SQ.FT. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 1/16/2018 9:56 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1700340 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 07/14/2017 GIS ID:35300010 FEE: 4880.00 MUNIS APPLICATION# 201700619 BUILDING DESCRIPTION: APPLICANT . LOCATION NAME: JACQUES CONSTRUCTION ADDRESS: 10 GILBERT LANE ADDRESS: 67 RIDGE ROAD .. �• OWNER: JACQUES CONSTRUCTION SOUTH WINDSOR,CT 06074 67 RIDGE ROAD 4aN_ SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: NEW HOME. 3,199 SQ.FT.- SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 7/14/2017 11:06 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1700335 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 08/04/2017 GIS ID:35300010 FEE: 300.00 MUNIS APPLICATION# 201700619 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: NUTMEG MECHANICAL SERVICES,INC. ADDRESS: 10 GILBERT LANE ADDRESS: 130-3 UTOPIA ROAD OWNER: JACQUES CONSTRUCTION MANCHESTER,CT 06042 67 RIDGE ROAD SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALLATION OF A NATURAL GAS DIRECT VENT FURNACE,CONDENSING UNIT AND KITCHEN EXHAUST VENT WITH INTAKE AIR VENT. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 8/4/2017 11:16 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1700350 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 10/11/2017 GIS ID:35300010 FEE: 180.00 MUNIS APPLICATION# 201700619 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ROSA ELECTRIC COMPANY,INC. ADDRESS: 10 GILBERT LANE ADDRESS: P.O.BOX 723 I OWNER: JACQUES CONSTRUCTION VERNON ROCKVILLE,CT 06066 67 RIDGE ROAD SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: 200 AMP SERVICE AND WIRING OF NEW HOUSE. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 1 0/1 1/2017 9:27 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1700391 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER PLUMBING PERMIT DATE: 09/05/2017 GIS ID: 35300010 FEE: 300.00 MUNIS APPLICATION# 201700619 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: GOTTIER PLUMBING&HEATING,INC. ADDRESS: 10 GILBERT LANE ADDRESS: P.O. BOX 1000 1' OWNER: JACQUES CONSTRUCTION VERNON ROCKV14 CT 06066 67 RIDGE ROAD s SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: PLUMBING FOR NEW HOME--DRAINS,VENTS,PEX WATER PIPING,UNDERGROUND PLUMBING FOR 1/2 BATH IN BASEMENT,GAS PIPING TO WATER HEATER,FURNACE AND FIREPLACE SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 9/5/2017 11:36 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE