October 11, 2004
Mr. Stuart Lipman
One Lipman Drive
South Windsor, CT 06074
Re: Removal and Disposal of(1)-1000 Gallon Underground Oil Tank
At: 1 Lipman Drive, South Windsor, CT 06074
Thank you for the opportunity to service the removal of one (1)-1000 Gallon Underground Oil tank
at the above referenced address.
The soil in the tank grave showed no signs of contamination and the grave was backfilled.
Before backfilling one(1) final confirmation soil sample was taken from the 1000 Gallon Underground
Oil tank grave and tested at an independent laboratory for TPH(total petroleum hydrocarbons)by IR
(Method 418.1). The soil sample results for the Bottom tank grave indicated BDL(Below Detection
Limits). The recommended TPH limit in a GA Classification is 500 parts per million.
This letter,along with the attached soil sample results, should be stored safely with all legal documents
pertaining to this property. This information, along with your Tankworks invoice and cancelled
check(s), will serve as verification for future reference.
Please feel free to call us if you have any further questions. It has been a pleasure working with you.
We hope that you are pleased with our services and that you will recommend us to others.
Very truly yours,
TANKWORKS REMOVAL & REPLACEMENT LLC
Rosemary Viola Rainville
Owner
cc: Town of South Windsor,Fire Marshal's Office, 1540 Sullivan Avenue, South Windsor,CT 06074
1-800-653-3140 Main Office 360 East Center St. Manchester CT 0.040
LIPMA1VFINALDO
0 ,\tt ACpp9O
PHOENH :
e `N
Environmental Laboratories, Inc.
587 East Middle Turnpike,P.O.Box 370,Manchester,CT 06040
Tel.(860)645-1102 Fax(860)645-0823
Analysis Report FOR: Attn: Mrs.Rose Rainville
Y Tankworks, Inc.
October 11, 2004 360 East Center Street
Manchester, CT 06040
Sample Information Custodv Information Date Time
Matrix: SOIL Collected by: DO 10/07/04 11:00
Location Code: TANKWKS Received by: SW 10/07/04 15:10
Rush Request: RUSH24HR Analyzed by: see "By" below
P.O.#:
SDG I.D.: GAF92185
Laboratory Data Phoenix I.D.: AF92185
Client ID: 1 LIPMAN RD BOTTOM
Parameter Result RL Units Date Time By Reference
Percent Solid 95 % 10/08/04 K/E E160.3
Tot.Petroleum HC BDL 21 mg/Kg 10/08/04 PJ E418.1
Comments: ND=Not detected BDL =Below Detection Limit R.L=Reporting Limit
If there are any questions regarding this data,please call Phoenix Client Services at extension 200.
Phyllis hiller,Laboratory Director
October 11,2004
Page 1 of 1
�O �N ACCOgoH
t-
as a=
Environmental Laboratories, Inc.
587 East Middle Turnpike,P.O.Bog 370,Manchester,CT 06040
Tel.(860)645-1102 Fax(860)645-0823
QA/QC Report
October 11, 2004 QA/QC Data SDG I.D.: GAF92185
Parameter Blank LCS Rec % MS Rec % RPD
QA/QC Batch Sample No:AF91325 (AF92185)
Tot.Petroleum HC BDL 97 91 NR
If there are any questions regarding this data,please call Phoenix Client Services at extension 200.
LCS -Laboratory Control Sample AOL
MS -Matrix Spike
RPD -Relative Percent Difference
Between Sample and Sample Duplicate Phyllis hiller,Laboratory Director
October 11,2004
Page 1 of 1
LOT 3/ 42
N
99. 28
I \
O
2050� 36.00
'4z. EXISTING
GARAGE
- z
LOT
30 LOT 29
38, 687.88 sq ft o
� m
N O
2/.O CDN
/000 GAL EPTIC
R !1 TA N1( ,O
0 �J
cp 23.
N
a
o �
50 B G LINE Is
O� Q
9 0
I P,
/5 .56
to .Srocr<ROE�cE
ELLINGTON ROAD
BEING LOT 29 ON MAP ENT/TLE
SAND HILL ESTATES
MAY 2 , 1970
FOUNDATION CERTIFIED AS
SHOWN MAY I3, 1972 PLOT PLAN FOR
" L / P M A N
EL L ING TON ROAD-SOUTH WINDSOR, CONN.
SCALE /" = 4p MARCH 2 8, /972
✓AMES E. SHEEHY LS.7034 CERTIFIED MAY 13, 1972
SEPTIC SYSTEM �
LOT 3/ 42- L:^dE+L FEE?` OF'TILE PER
99.28
o�
� ru �� ,r;:;�r� 12 FEET C.O.C. rntv.:
ol
-
20.0 36.00 N Cl
N PROPOSED
GARAGE
LOT .
30 J LOT 29
38,68788 sq ft o
0
VO
. 2. Q�0 yQ p o •¢ � � - .
210 \ N
IOOANA L EPT/C, o
° -- 50 8L 00 ONE
I
1 I 90 000 -
D',,2g2'I
( I 15756 P''3
El—l—INGTO/V ROAD
:v
• BE/NG LOT 29 ON MAP ENT/TLE tSAND HILL ESTAYES "
MAY 21 1970
-.-_r •11 •,safe r 'V ,r.
PLOT PLAN FOR ,`�`' •_" - ~'
L
A N ,. .
ELL/NGTON ROAD—SOUTH
!�Y/NDSOR CONN. - =
Y • s
3 CAL E �„ = 40
MARCH 2 8, /972 » •�°�
✓ANES E. SHEEHY LS.7034
r f
APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Applic by: BUILDING DEPARTMENT I V) l�
r APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
.l 644-2511 ext. 230
Date lding Inspector --
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 w ,
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS W ,�6 CJUCbD Q�
APPLICANT'S PHONE# <I�`'�"—1;d9 —S2 l I
OWNER UA(��
WN S
.�Or F4< OWNER ADDRESS L ��
OWNER PHONE
O ? ESTIMATED COST$
C IS THIS A CONTRACT COST? 4/"'Yes No
FEE ENCLOSED$ J�C)
TYPE OF JOB:
�$0 CQ� New Installation old U U S(o
✓ Alteration/Addition/Repair
Revised 03/05/10
WcaC L(L-5 /(S A)U wixl o z,0
r
APPLICATION FOR HVAC PERMIT(Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
YHEATING ❑ RESIDENTIAL
YA/C ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
LVHYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)-Ul'tJ P(JkjTG0
ho
GROSS HEATING CAPACITY(INPUT-BTUH) 149" NET RATING(OUTPUT BTUH)
TYPE OF FUEL ��'
li(OIL-GPM OIL TANK LOCATION: dINSIDE ❑ OUTSIDE CAPACITY
❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE 'I °F INSIDE OF DIFFERENCE I OF
TOTAL HEAT GAIN(BTUH)a o K (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE& MODEL NO.)
CD v 't ►J ai o1�`d
TONNAGE _ COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
3a67b1 __ j
CONTRACTORS LICENSE TYPE STATE
SIGNATURE OF APPLICANT /hki& DATE QS�/ a I l 6
Lipman 1 Lipman Dr OSouth VVindsor Main & 2nd F-Ir
HVAC Load Calculations
for
Stuart Lipman
I Lipman Drive
South Windsor,CT 06074
AUT E.W.Irkll
zv,77 ri rT- erN- RESID9NMAL
�
H VA C L oADs
Prepared By:
Chris Miller
BBT Mechanical Services, LLC
22 Wapping Wood Rd
Ellington,Connecticut 06029
860-209-9917
Wednesday, May 12,2010
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. „
BBT Mechanical Services Lipman 1 Lipman Dr South Windsor Main&2nd Fir
Ellington,CT 06029 Page 2
Proiect Report
General Project Information
Project Title: Lipman 1 Lipman Dr South Windsor Main&2nd Fir
Designed By: Chris Miller
Project Date: Friday May 04,2007
Client Name: Stuart Lipman
Client Address: 1 Lipman Drive
Client City: South Windsor,CT 06074
Client Phone: 860-436-1234
Company Name: BBT Mechanical Services,LLC
Company Representative: Chris Miller
Company Address: 22 Wapping Wood Rd
Company City: Ellington,Connecticut 06029
Company Phone: 860-209-9917
Company Fax: 860-871-9422
Company E-Mail Address: bbtmechanical@snet.net
EDesign Data
Reference City: Hartford, Connecticut
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 41 Degrees
Elevation: 19 ft.
Altitude Factor: 0.999
Elevation Sensible Adj.Factor: 1.000
Elevation Total Adj.Factor: 1.000
Elevation Heating Adj.Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter. -10 -10.4 81% n/a 72 n/a
Summer: 93 73 39% 50% 75 25
Check Figures
Total Building Supply CFM: 1,468 CFM Per Square ft.. 0.577
Square ft. of Room Area: 2,544 Square ft. Per Ton: 694
Volume(ft')of Cond.Space: 19,347
Building Loads
Total Heating Required Including Ventilation Air: 63,740 Btuh 63.740 MBH
Total Sensible Gain: 32,999 Btuh 91 %
Total Latent Gain: 3,439 Btuh 9 %
Total Cooling Required Including Ventilation Air: 36,437 Btuh 3.04 Tons(Based On Sensible+ Latent)
3.67 Tons(Based On 75%Sensible
Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
y
J
w
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
BBT Mechanical Services Lipman 1 Lipman Dr South Windsor Main&2nd Fir
Effiroon.CT 06M Page 4
Load Preview Report
Net, ft2: Sen Lat Net! Seni Sys, Sys Sys pact
i Htg' Clg'. Act;
Scope Ton JTon Area: Gain' Gain Gain; Loss" Size
CFM, CFM; CFM,
Building 3.04 838 2,544 32,999 3,439 36,437 63,740 785 1,468 1,468
System 1 3.04 838 2,544 32,999 3,439 36,437 63,740 785 1,468 1,468 14x17
VerClation 732 635 1,367 3,335
Duct Latent 163 163
Zone 1 1,578 24,680 2,128 26,803 37,226 484 1,123 1,123 12x16
1-Green Bed Room 2nd F1 103 2,211 249 2,460 2,504 33 101 101 1_6
2-Myra's Office 2nd FI 104 2,158 251 2,409 2,143 28 98 98 1--6
3-Exercise Room 2nd Fl 119 2,547 319 2,866 3,665 48 116 116 1--6
4-Stuart's Bedroom 2nd Fir 228 2,289 565 2,854 5,304 69 104 104 1--6
5-Stuart§Bath&Closets 2nd Fir 135 1,745 83 1,828 Z758 36 79 79 1--5
6-2nd Fir Bath 44 120 0 120 177 2 5 5 1--5
7-2nd Fir Interior Hail 05' 176 0 176 261 3 a 8 1--5
8-Living Room Main Fi 275 5,922 389 6,311 6,959 90 269 269 2--7
9-tiring Room Again Fir 181 1,360 67 1,427 3,265 42 62 62 1--5
10-Kitchen Main Fir 159 428 0 428 638 8 19 19 1--5
11-Sun Room t.ain F6 165 5,725 205 5,930 9,552 124 -260 260 2--7
Zone 2 966 12,169 512 12,681 23,179 301 554 554 9x13
12-aua!'s0M.ce 181 1583 67 1,650 3,396 44 72 72 1--5
13-Front Entry 109 2,101 40 2,141 3,252 42 96 96 1-6
14-Family Room 1 311 0 0 0 871 11 0 0 0_0
15-Family Room 2 255 7,643 240 7,883 9,122 119 348 348 3 6
16-Back Room 110 842. 165 1,007 6,538 85 38 38 1--5
Sum of room airflows may be greater than system airflow because
system has multiple zones.
I +
AW
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. .
BBT Mechanical Services Lipman 1 Lipman Dr South Windsor Main&2nd Fir
Elfi CT 06M Page 6
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
1 D-cv-o:Glazing-Double pane,operable window,clear, 280.2 13,093 0 13,602 13,602
vinyl frame,u-value 0.57,SHGC 0.56
1E-cw:Glazing-Double pane window,fixed sash,clear, 28.9 1,328 0 1,468 1,468
wood frame,u-value 0.56, SHGC 0.66
1E-cv:Glazing-Double pane window,fixed sash,clear, 17.6 808 0 894 894
vinyl frame, u-value 0.56,SHGC 0.66
1OB-b:Glazing-French door,double pane clear glass, 38.1 2,342 0 858 858
metal frame with break, u-value 0.75, SHGC 0.47
1E-cv:Glazing-Double pane window,fixed sash,clear, 17.9 820 0 1,116 1,116
vinyl frame, u-value 0.56,SHGC 0.66
11 G:Door-Wood-Panel 21 930 0 329 329
12B-Osw:Wall-Frame, R-11 insulation in 2 x 4 stud cavity, 1655.6 13,170 0 4,353 4,353
no board insulation,siding finish,wood studs
1613-19:Roof/Ceiling-Under Attic with Insulation on Attic 1833.6 7,367 0 4,762 4,762
Floor(also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, Dark Asphalt
Shingles or Dark Metal,Tar and Gravel or
Membrane, R-19 insulation
20P-19:Floor-Over open crawl space or garage,Passive, 103.2 423 0 67 67
R-19 blanket insulation,any cover
19A-19p:Floor-Over enclosed unconditioned crawl 546.2 1,720 0 378 378
space,No insulation on exposed walls,sealed or
vented space, passive, R-19 blanket
22A-pm:Floor-Slab on grade,No edge insulation, no 40 3,871 0 0 0
insulation below floor,any floor cover, passive, heavy
dry or light wet soil
Subtotals for structure: 45,872 0 27,827 27,827
People: 6 1,200 1,380 2,580
Equipment: 0 0 0
Lighting: 0 0 0
Ductwork: 0 163 1,400 1,563
Infiltration:Winter CFM:161,Summer CFM:84 14,533 1,440 1,660 3,100
Ventilation:Winter CFM_37,Summer CFM:37 3,335 635 732 1,367
Total Building Load Totals: 63,740 3,439 32,999 36,437
Check Figures - ---
Total Building Supply CFM: 1,468 CFM Per Square ft.. 0.577
Square ft.of Room Area: 2,544 Square ft. Per Ton: 694
Volume(ft?)of Cond.Space: 19,347
B�filding Leads - -
Total Heating Required Including Ventilation Air: 63,740 Btuh 63.740 MBH
Total Sensible Gain: 32,999 Btuh 91 %
Total Latent Gain: 3,439 Btuh 9 %
Total Cooling Required Including Ventilation Air: 36,437 Btuh 3.04 Tons(Based On Sensible+ Latent)
3.67 Tons(Based On 75% Sensible
Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Rhvac.Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
BBT Mechanical Services CLipman 1 Lipman Dr South Windsor Main&2nd Fir
Eifi on,CT OW29 Rage 32
System 1 Room Load Summary (cont'd)
Equipment Data
Brand: WTGO SERIES 3 RUUD UAND SERIES
Description: Oil Boiler
Efficiency: 85 AFUE 13 SEER
Sound:
Capacity: 145,000 Btuh 34,800 Btuh
Sensible Capacity: n/a 26,100 Btuh
Latent Capacity: n/a 8,700 Btuh
AHRI Reference No.. n/a 3176027
i I Rhvac-Residential&Light Comrnorclal HVAC loads ,"; Elite Software Devebpment,lnc. .
i 2nd Fir
BBT Mechanical SenServices Lipman 1 Lipman Dr South Windsor Main 8�
(�}FEtFr n,CT 06029 ti _ a `� S1J
4
System 9 Room Load Summary _
� W Htg Htg RU F Run C g Clg CI9 Air
Roorn't Area Sens Rad Duct Duct Sens Lat Nom Sys
No Name S1= Btuh Len Size Vel Btuh Btuh CFM CFNt,
-Zone 1-
1 Green Bed Room 103 2,504 4.4 1-6 512 2,211 249 101 101
2nd FI
2 Myra's Office 2nd 104 2,143 3.8 1-6 500 2,158 251 98 98
FI
3 Exercise Room 119 3,665 6.5 1-6 590 2,547 319 116 116
2nd FI
4 Stuarts Bedroom 228 5,304 9.3 1-6 530 2,289 565 104 104
2nd Fir
5 Stuart's Bath & 135 2,758 4.9 1-5 582 1,745 83 79 79
Closets 2nd Fir
6 2nd Fir Bath 44 177 0.3 1-5 40 120 0 5 5
7 2nd Fir Interior 65 261 0.5 1-5 59 176 0 8 8
Hall
8 Living Room Main 275 6,959 12.3 2-7 504 5,922 389 269 269
FI
9 Dining Room 181 3,265 5.7 1-5 454 1,360 67 62 62
Main Fir
10 Kitchen Main Fir 159 638 1.1 1-5 143 428 0 19 19
11 Sun Room Main 165 9,552 16.8 2-7 487 5,725 205 260 260
Fir
Zone 1 subtotal 1,578 37,226 65.5 24,680 2,128 1,123
---Zone 2-
12 Stuart's Office 181 3,396 6.0 1-5 528 1,583 67 72 72
1 13 Front Entry 109 3,252 5.7 1-6 487 2,101 40 96 96
14 Family Room 1 311 871 1.5 0-0 0 0 0 0 0
15 Family Room 2 255 9,122 16.1 3-6 590 7,643 240 348 348
16 Back Room 110 6,538 11.5 1-5 281 842 165 38 38
Zone 2 subtotal 966 23,179 40.8 12,169 512 554
Ventilation 3,335 732 635
Duct Latent 163 _
System 1 total 2,544 63,740 106.3 32,999 3,439 1,468 11468
System 1 Main Trunk Size: 14x17 in.
Velocity: 888 ft./min
Loss per 100 ft.: 0.101 in.wg
Note: Since the system is multizone,the Peak Fenestration Gain Procedure was used to determine glass sensible gains
at the room and zone levels,so the sums of the zone sensible gains and airflows for cooling shown above are not
intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour
in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the"Average
Load Procedure + Excursion" method.
I Cooling System Summary
Cooling Sensible/Latent Sensible Latent To
_ Tons_ Split Btuh Btuh Btu
Net Required: 3.04 91%/9% 32,999 3,439 36,437
1 Recommended: 3.67 75%/25% 32,999 11,000 43,998
I Actual: 2.90 75%/25% 26,100 8,700 34,800
Equipment Data _ _ A
Heating System Cooling System
Type: Fuel Oil Boiler Standard Air Conditioner
Model: P-WTGO-4 UAND-036JAZ
Indoor Model: RCFA-H'3617A'
Electric# APPLICATION FOR BUILDING PERMIT
Mumbing# I Lipman Drive Date: /56'I
HVAC #
Sprinkler# 30935
FINAL APPROVALS _—_— __--- -- _ - - Estimated Cost $ 7uu
Building COMPLETE RED BOXED AREAS Permit Fee $
Engineering Occupancy Fee $
g TYPE OR PRINT ONLY Eng. Insp. Fee $
Affidavit ► SIGN ON REVERSE SIDE
Appr. for CO. J Total Fee $
TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant /-1k Du/% R' Location of Work Dr. (14-n ) Lot No.
Applicant's Address 7N &1-4 ST. Tel.# - 1W-Yiko
Town H. cT Zip bb/1-? Lic.# 10/9Y
Owner Architect
Owner's Address I. Architect's Address
Zip Zip
Sq. Ft. New Area: 1st FI. 2nd FI. 3rd FI. Total New Area
Purpose of this permit Tckr o ; Q?0h-s I (<xe�sg4id T.%ft4/t r« > w<fe s4, -Id
City Water❑ Well❑ Septic System❑ Sewer❑
Ins: HO L—AP6'6PZ�ate -65/16
ea Basement Garage
Approved byUse Gro onstruction T
J(wd / Revised W02
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of ,
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked.and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this building and its use is allowed.
Signedw�
1 hereby apply for a Certificate of Occupancy for the work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
Inspection / Approval Date By Appl
Code Description Due whom Code Comment
-------------------------------------------------------------------------------
•"-30935-8 5,700
B10 FINAL 09/14/04 PJP A
B10 FINAL 09/14/04 PJP A CLOSEOUT
I,
Electric# APPLICATION FOR BUILDING PERMIT
Plumbing# 1 Lipman Drive
HVAC # Date: � U U
Sprinkler# 30878 Estimated Cost $ 7200.0 6
FINAL APPROVALS - -- _— ------- - - --- -, � Permit Fee $ I z a• o e
Building COMPLETE RED BOXED AREAS
Engineering Occupancy Fee $
TYPE OR PRINT ONLY
Affidavit g Eng. Insp. Fee $
Appr. for CO. y SIGN ON REVERSE SIDE Total Fee $ /o20.
TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant M. G. T o S?A R E t_L i .r R Location of Work 1 L i P M A A) D& Lot No.
Applicant's Address b a G A R o CA) S T. E . FI A Rs Entz o . c I:. n b i o g Tel.#SSA-t j_s-S `v i i 6 ti i
Town EAST H A R T r-a R p C T. zip—0 t.10 b Lic.# .S a 0
Owner cju A RT (-I P MAty Architect
Owner's Address i l t Pry A a Op'. Architect's Address
SnuiN W(NDSOR L?- Zip O4o,7,-/ Zip
Sq. Ft. New Area: 1st Ff. 2nd FI. 3rd FI. Total New Area
Purpose of this permit JEPR -OFF t' tSTtNc-. SiPiryc — wot)SE GARAaE
(ZE t N S7RL4, Ew S�D//yG Nc lklm A-PPR X 3Goc as t�
City Water[:] Well❑ Septic System❑ Sewer❑
Ins: HO rt Area Basement Garage
�j
Approved by ate d Use Group 'Construction Type.--�'—
Revised 6/02
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this building and its use is allowed.
Signed M ,b �, oak!
I hereby apply for a Certificate of Occupancy for the work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
I
I
Inspection / Approval Date By Appl
Code Description Due whom Code Comment
-------------------------------------------------------------------------------
**-30878-B 7,200
B10 FINAL 09/14/04 PJP A
B10 FINAL 09/14/04 PJP A CLOSEOUT
r
� F
{
j�
\V�L! ArJ D 1V DC> / �4x� K f�r �-c"� • Imo"r
- - "'7
o\ iGE ODL-Ut-" AND HEAGe7P.
-- - EX4�. 1tJG- SLICE (z 0
J 2.E L rr A?M_i �ti (�Szt)*�3�'►- l-� t,✓ Ez- A` 1I"' ';-�f
TRIM
_-•� �,' t-� NE�V � E)CI�TItJ� = X � Pt>r� p,t��r.�• NE1�! \ . .—
_ , C�F'�i'�if~ iC � k � �OF L�1.1�• /IGf�' - -� E�.VE To t'It�T"�I �x�T,. _`�
. � / _� �Nv t E.iS'.a►(-.i. tl�ica - (1JcaT�1..L �;�`:v' ��'i�'z-•
cxQ4T T
�zit�JSLDoTt'!�'i7� ��
— Q v 1 hJE\\f GOB M, iS IEb.i;)ER
1E..f✓Cock-,lryC7 Q, >C.�-
J '
r~.) G
�A6E Et -`'r Oc�w) \VI' ► C�, I i - T
-.i�
I ST1 K c �L(x,� �� .�' T"s U EL F t�
I
r;
13
+71
f 6c)I�j( R-LTE Ft
7 fts� ce „1xD LPL. u�,�---- --7�'- I� et- !fit L i C,Q L-r.. \`r'/�`,Ct�?';LAWPING 121' 72_.
; 4' _ 2:t
E5E LL'�)\V NEw p
V
F L C�C��. P ice. _
VERTICAL SECTION T _�•�
It
3.4 BOW WINDOW DETAILS
HORIZONTAL SECTION
AN D PP_
ti L J
S`' j ,�(!.i - rii�...i� !`.G�� i^•�.�%.r-- I ,.t`r+ i� �tN i ew., �-^
�— _ _ ---- -- - -
`t -- j __, . -- _-' - ---- ;f��tjk i i. i.i�':' �!Dt►.�C� To
V D'+ E
iII Lv;�E7C.7\�/ � ..: I-}�o� O{= �k. � 8E�• �R. ,.}�'jE1'i�
P5 T E56 CY
-
g
i � i i N���C�o�� i ! i i ► i � � aU�r� rJ�+;•� `' � I � I �`� ._._.
• J i
v
o
I L—E-VAT 10
� o
o �
C/G BY
O�Zi�lh.f �•24
1000170 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 05/13/10
GIS ID:53700001 FEE: 240.00
MUNIS APPLICATION# 201000561 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: BBT MECHANICAL SERVICES,LLC ADDRESS: 1 LIPMAN DRIVE
ADDRESS: 22 WAPPING WOOD ROAD OWNER: LIPMAN STUART G
ELLINGTON,CT 06029 1 LIPMAN DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: BOILERAND A/C.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
5/13/2010 9:18 AM THE FEE ABOVE INCLUDES A$0.22 PER THOUSAND CT STATE EDUCATION SURCHARGE