HomeMy WebLinkAbout0 MILL POND DR BLDG#2 �obtt53060a
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: I-1 U O l
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE
Bldg. Permit#
644-2511 ext. 230
Date Building Inspeck r
Application must be printed or typed
FEE SCHEDULE
Location of Job:
F
$0-$1,000=$15.00 Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof gnation Apt.No.
APPLICANT L-J lej (nh-t(�
APPLICANT ADDRESS 2n L2 SC5X
ntinq b
APPLICANT PHONE#
OWN Se OWNER nP_ TJ( t I
OWNER ADDRESS
0 +o OWNER PHONE -z9Q'3--aQDjj
C ESTIMATED COST$
•1 # U
IS THIS A CONTRACT COST? _Yes _No
FEE ENCLOSED$ p�Q -
f r so 0 TYPE OF JOB: W O 7yS
R C ew Installation
_Alteration/Addition/Repair
` 2a i-7vasy
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side) '
TYPE OF YSTEM: TYPE O`F�UILDING: ti
HEATING )Q RESIDENTIAL
A/C ❑COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL H TIN QUIPMENT ING MAKE&MOD NO.
U(
GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
❑OIL-GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY
❑GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
ESCRIBE ALL COOLING EQUIPMENT(INC � � �
MAKE&MODE NO.)
o drw��1 c ��IS rn
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE TYPE STATE
SIGNATURE OF APPLICANT DATE I
Corporate Office
600 Old County Circle, P. O. Box 548, Windsor Locks, CT 06096
Local 860-292-2600 • Fax 860-292-2690
SAFETY Connecticut Toll Free 1-888-956-4455
HOMESERVICEStii:l�,s►ty� AielloHomeServices.com • Aiello is an AA/EOE
5I01I-}
To Whom This May Concern:
Aiello Home Services Authorized Alesha Fillmore, Lorie Metivier,Stephen Birch, Robert
Bilodeau, Nick White, , Stacy Dlubac, Cindy Nicewicz,Tim Lynch, Mike Loscialpo, Matt Rose, and
Keith Miller and Scott Matyskiela to pull permits for our company for any Plumbing, Heating, or
Air Conditioning replacement(s) or new Installation(s). If you have any questions please call our
office at 860-292-2600.
This Letter is for a permit for the property located at:
Home Owner: -?�C1P GfI-PI (1
Permit Fee Amount: $ 7
Sincerely,
Michael Jezouit
President
HEATING,PIPING&COOLING UNU IITED CONTRACTOR
MICHAEL R JEZOUIT
PO BOX 548
WINDSOR LOCKS,CT 06096-0548
LIC./REG NO. EFFECTIVE EXPIRE
HTG.0303032-S1 09/01/2016 08/31/2017
SIGNED
HEATING • PLUMBING • ELECTRICAL • GENERATORS • OIL DELIVERY • HOME AWARENESS • AIR CONDITIONING
6115
Company Info
Name: Company
Address:Add1
Location: City, State, 55555
Phone: 555 555 5555
Client Info
Building name/description: 201 Mill Pond Dr.
Contact name:Jane Griffin
Address: 201 Mill Pond Dr.
Location: South Windsor, Connecticut, United States
Phone:
Load Summary
Total building area: 1,330.0 SgFt
Total cooling load: 27,189.2 BTUh
Total cooling tonnage: 2.3 tons
Total heating load: 47,534.7 BTUh
Total airflow: 1,071.2 CFM
ACCA-Approved Manual J8 Calculations 07:32:04 05-10-2017
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual J8 residential HVAC load calculations.
Checksums - Cooling
Total building area (SgFt): 1,330.0
Total building volume (CuFt): 10,640.0
Total cooling sensible load (BTUh): 23,552.7
Total cooling latent load (BTUh): 3,636.4
Total cooling load (BTUh): 27,189.2
Total 2
): .tons tonnage 3
(
Total cooling infiltration airflow (CFM): 51.9
Total cooling ventilation airflow (CFM): 8.9
Total airflow (CFM): 1,071.2
Total infiltration air changes/hr(ACH): 0.29
Sensible heat coefficient (SHC): 1.10
Latent heat coefficient (LHC): 0.68
Cooling load density (BTUh/SgFt): 20.44
Cooling airflow density (CFM/SgFt): 0.81
Cooling airflow/load (CFM/Ton): 472.8
Cooling area/load (SgFtlron): 587.0
Checksums - Heating
Total building area (SgFt): 1,330.0
Total building volume (CuFt): 10,640.0
Total heating load (BTUh): 47,534.7
Total airflow (CFM): 1,071.2
Total building air changes/hr (ACH): 6.04
Sensible heat coefficient (SHC): 1.10
Latent heat coefficient (LHC): 0.68
Heating load density (BTUh/SgFt): 35.7
Heating airflow density (CFM/SgFt): 0.81
ACCA-Approved Manual J8 Calculations 07:32:04 05.10-2017
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual J8 residential HVAC load calculations.
Block Load Breakdown -Cooling
Description Value %
Windows and glass doors: 6,944.5 25.5%
Skylights: 2,287.4 8.4%
Wood and metal doors: 366.9 1.3%
Above grade walls: 3,190.3 11.7%
Partition walls: 340.7 1.3%
Below grade walls: 0.0 0.0%
Ceilings: 2,406.8 8.9%
Floors: 822.4 3.0%
Infiltration: 2,126.7 7.8%
Internal gain: 3,090.0 11.4°%
Duct heat gain: 2.876.0 10.6%
Ventilation: 363.2 1.3%
Blower heat gain: 1.707.0 6.3%
Excursion adjustment load: 667.3 2.5%
Total cooling: 27,189.2 100%
Block Load Breakdown-Heating
Description Value %
Windows and glass doors: 10,990.7 23.1%
Skylights: 734.1 1.5%
Wood and metal doors: 874.9 1.8%
Above grade walls: 9,199.8 19.4%
Partition walls: 1,651.1 3.5%
Below grade walls: 0.0 0.0%
Ceilings: 2,984.4 6.3%
Floors: 3,919.5 8.2%
Infiltration: 8.421.7 17.7%
Duct heat loss: 8,153.9 17.2%
Ventilation: 604.4 1.3%
Hot water piping load: 0.0 0.0%
Winter humidification load: 0.0 0.0%
Total heating: 47.534.7 100%
ACCA-Approved 07.3 .0 5-roved Manual J8 Calculations 2 4 0 10-2017
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual A residential HVAC load calculations.
Room Heating and Cooling Totals
Room Name Cooling Load (BTUh) Heating Load (BTUh) Airflow (CFM)
A Room 0.0 0.0 0.0
Totals 0.0 0.0 0.0
ACCA-Approved Manual J8 Calculations 07:32:04 05-10-2017
This software was developed by Carmel Software Corporation,
It has boon approved by ACCA for Manual J8 residential HVAC load calculations,
System Block Load Breakdown -Cooling
Windows,glass doors.skylights: =STUN
Envelope(walls,doors, roof,etc.): 8TUh
Infiltration: BTUh
Internal --- — - -- STUh
Duct and blower heat gain:ilk 8T181
Ventilatkm:} 3631 8TUh
Excursion adjustment load: 667.3 8TUh
Total cooling: 27.189.2 STUh
System Block Load Breakdown - Heating
Windows,glass doors,skylights: 11,724.8 BTUh
Envelope(walls,doors.roof,etc.): 18,629.8 BTUh
InfiltratkM: .7 BTUh
Duct heat loss: BTUh
Ventilation/winter humidification: _ BTUh
Hot water piping load BTUh
Total heating: 47,534.7 BTUh
System AEO Cur"
A® —&wsp liar+ —LWA Lrr►
14.707
12AM
11 Q�0
9,192
7,M
6,616
3r8 ?
8 9 10 11 12 13 14 16 18 17 18 19 20
NOW Of nay
ACCA-Approved Manual J8 Calculations 07:32:04 05-10-2017
i This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual J8 residential HVAC load calculations.
(ow" 3 q
' = Town of South Windsor Building Department
OR•CO�[,
HVAC PERMIT: HVAC-21-37
APPLICANT
NAME: Kevin Moriarty
EMAIL ADDRESS:jim@harpmech.com
ADDRESS:483 Spring
Windsor Locks, CT 06096
LOCATION
ADDRESS: 205 MILL POND DRIVE
South Windsor CT 6074
OWNER: BOLES DENISE
205 MILL POND DRIVE
SOUTH WINDSOR CT 6074
DESCRIPTION OF WORK:
Remove and replace the existing gas furnace with new Lennox brand SL280UH07OXV36B furnace and controls.
February 5, 2021
BUILDING OFFICIAL DATE SIGNED
"'ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT"`
—PERMIT ONLY VALID IF SIGNED BY BUILDING OFFICIAL—
Electric # APPLICATION FOR BUILDING PERMIT
Plumbing# LO ED
HVAC# DCD• �e 17_176 h4'1� Vnc'CA ����� Date: JUIVb AY orb/a
Sprinkler# 1 Q 'wq�
FINAL APPROVAL Estimated Cost $ 1419, 4Y-1
Building CGS 29-3 15 COMPLETE RED BOXED AREAS Permit Fee $ ar ys-z
Occupancy Fee $
Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $
Affidavit
Appr.forCO. ► SIGN ON REVERSE SIDE 4 Total Fee $ -D, y�
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ 3�y`b`f
The undersigned hereby applies to do work according to the following:
Applicant�2IyA�Y1 Af�1_ �H p.Cr.V I►J�Location of Work!STRAwBt i D.C-{�, 1&Z Lot No.
Applicant's Address q_ 141_L-(_,_ KQ
} p _ Tel
Town.-(j-)N4 -1�{ �/Yl __ M�5 AC_kj US IF-Mn Zip S Lic.#
Owner ST'�Ja_`Q Architect EGGVn UG.
Owner's Address 2,6�08 M i�U, R7 D _DR_- Architect's Address 21— C.6 u gX.V) . ?2.s cT'
la i1.7C $ l Y GT _._ Zip ObD?�} -___—� ltkxjL AZ7 Zip 4-,J�93R
Sq. Ft. New Area: 1 st Fl. (�_2nd Fl. 4'f _3rd Fl. �I Total New Area �S
Purpose of this permit > S�d�ac� �lAr... {-►.Tr
City Water3S Well J Septic System J Sewer c-,DbI--I-oo7qb
Ins: HO S Cert. Area Basement Garage
Approved v Date C, S 12 Use Group Construction Type
Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this building an i use is allowed.
Signed
I hereby apply for a Certificate of ccupancy!forthe ork described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS