HomeMy WebLinkAbout0 MILL POND DR BDLG #28 LO APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 16t)00 }6 APPRO 1540 SULLIVAN AVENUE Bldg. Permit# 644-2511 ext. 230 Date Building Insp o Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 &SS Uu tit 1 10(A Rd d Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt. No. 3APPLICANT n%C,110FIG (1Q. ' C V�(3-S r APPLICANT ADDRESS �G lJCIX 5uS INt1 6SG 1 'C�S CI CJ6C �o APPLICANT'S PHONE# O 'CCU c 60C> OWNER SOW N SF4< OWNER ADDRESS OWNER PHONE 60 �- Q « ' ESTIMATEDCOST$ 41 Wo ,•� « U IS THIS A CONTRACT COST? Ycs No FEE ENCLOSED $ 5 (,b TYPE OF JOB: SOR-Co New Installation -:YAlteration/Addition/ Repair �piSoolto Revised 03/05/10 c APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE QF UILDING: tHEATING 2&XSIDENTIAL c ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC Cl WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) QoCdwan Q _ S)(1 - 19' GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION:Cl INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQPIPMENT(INCLUiWNG MAKE&MODEL NO.) TONNAGE _ COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK (a S )VRZR hm THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE N TYPE STATE SIGNATURE OF APPLICAN a4�. � DATE �� Corporate Office ACELLO 600 Old County Circle, P. O. Box 548, Windsor Locks, CT 06096 LICENSED FOR Local 860 292 2600 • Fax 860-292-2690 SAFETY Connecticut Toll Free 1-888-956-4455 HOME SERVICES �bi•y. s�'I' AielloHomeServices.com • Aiello is an AA/EOE 1-dk-�5 To Whom This May Concern: Aiello Home Services Authorized Alesha LaBelle, Stephen Birch, Dave Howard, Garrett Cardwell, Randy Weidig, Robert Bilodeau, Nick White, Mark Putori, Kevin Vaughan, Lorie D'Appollonio, Stacy Dlubac, Cindy Nicewicz,Tim Lynch, Keith Tyler, Matt Cormier, Dave Arildsen, Bill Faitella, Joe Arroyo, William Asprelli, Matt Rose to pull permits for our company for any Plumbing, Heating, or Air Conditioning replacement(s) or new Installation(s). If you have any questions please call our office at 860-292-2600. This Letter is for a permit for the property located at: - c6CM MCU Pbe\A R�\ -t>ac>:1 W,h&CcC C� OROoO Home Owner:_A t+mP S GZ7 Permit Fee Amount: $ Sincerely, 11114 Michael Jezouit President STATE OF CONNECTICUT DEPARTMENT OF CONSUMER PROTECTION LIMITED SHEET METAL CONTRACTOR HEATING,PIPING&COOLING UNLIMITED CONTRACTOR MICHAEL R JEZOUIT MICHAEL R JEZOUIT PO BOX 548 PO BOX 548 WINDSOR LOCKS,CT 06096-0548 I WINDSOR LOCKS;�CT 06096-0548 LI /REG NO. EFFECTIVE EXPIRES LIC.I REG NO. EFFECTIVE EXPIRES HTG.0303032-S1 097/2014 08/31/2015 SHM.0005345-S / 09/01/2014 08/31/2015 SIGNED / b SIGNED t HEATING • PLUMBING ELECTRICAL • GENERATORS • OIL DELIVERY • WATER QUALITY • AIR CONDITIONING 9114 „ ✓ Company Info Name:AIELLO HOME SERVICES Address: 600 old county circle Location: WINDSOR LOCKS, State, 06096 Phone: 860-292-2600 Client Info Building name/description: Condo Contact name:James scozzafava Address: 2804 mill pond rd south windsor, ct. 06074 Location: South windsor ct, Connecticut, United States Phone: Load Summary Total building area: 1,200.0 SgFt Total cooling load: 19,138.2 BTUh Total cooling tonnage: 1.6 tons Total heating load: 39,761.1 BTUh Total airflow: 953.9 CFM ACCA-Approved Manual J8 Calculations 23:31:21 01-27-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual JS residential HVAC load calculations. • Checksums - Cooling J / Total building area (SgFt): 1,200.0 Total building volume (CuFt): 9,600.0 Total cooling sensible load (BTUh): 15,662.2 Total cooling latent load (BTUh): 3,476.0 Total cooling load (BTUh): 19,138.2 Total tonnage (tons): 1.6 Total cooling infiltration airflow (CFM): 0.0 Total cooling ventilation airflow (CFM): 59.5 Total airflow (CFM): 953.9 Total infiltration air changes/hr (ACH): 0.00 Sensible heat coefficient (SHC): 1.09 Latent heat coefficient (LHC): 0.68 Cooling load density (BTUh/SgFt): 15.95 Cooling airflow density (CFM/SgFt): 0.79 Cooling airflow load (CFM/Ton): 598.1 Cooling area/load (SgFt/Ton): 752.4 Checksums - Heating Total building area (SgFt): 1,200.0 Total building volume (CuFt): 9,600.0 Total heating load (BTUh): 39,761.1 Total airflow (CFM): 953.9 Total building air changes/hr (ACH): 5.96 Sensible heat coefficient (SHC): 1.09 Latent heat coefficient (LHC): 0.68 Heating load density (BTUh/SgFt): 33.1 Heating airflow density (CFM/SgFt): 0.79 ACCA-Approved Manual J8 Calculations 23:31:21 01-27-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. • Block Load Breakdown -Cooling Description Value % Windows and glass doors: 1,302.1 6.8% Skylights: 0.0 0.0% Wood and metal doors: 390.6 2.0% Above grade walls: 3,714.4 19.4% Partition walls: 0.0 0.0% Below grade walls: 0.0 0.0% Ceilings: 2,423.5 12.7% Floors: 1,260.6 6.6% Infiltration: 0.0 0.0% Internal gain: 3,090.1 16.1% Duct heat gain: 2,484.7 13.0% Ventilation: 2,703.8 14.1% Blower heat gain: 1,707.0 8.9% Excursion adjustment load: 61.4 0.3% Total cooling: 19,138.2 100% Block Load Breakdown - Heating Description value % Windows and glass doors: 3,098.2 7.8% Skylights: 0.0 0.0% Wood and metal doors: 882.0 2.2% Above grade walls: 9,974.5 25.1% Partition walls: 0.0 0.0% Below grade walls: 0.0 0.0% Ceilings: 3,084.5 7.8% Floors: 4,421.7 11.1% Infiltration: 5,232.4 13.2% Duct heat loss: 8,508.8 21.4% Ventilation: 4,559.0 11.5% Hot water piping load: 0.0 0.0% Winter humidification load: 0.0 0.0% Total heating: 39,761.1 100% ACCA•APP roved Manual J8 Calculations 23:31:21 01-27-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. • Room Heating and Cooling Totals Room Name Cooling Load (BTUh) Heating Load (BTUh) Airflow (CFM) A Room 0.0 0.0 D.D Totals 0.0 0.0 D.D ACCA-Approved Manual A Calculations 23:31:21 01-27-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual A residential HVA.0 load calculations. . ; System Block Load Bt akdown-Co*V Windows,glass doors,skylights:�= 1,302.1 BTL1h Envelope(walls,doors,roof,etc.): 7,789.1 BTUh ktfiltration: 0 BTUh Internal gain: BTUh Duct and blower heat gain:NNr- .7 BTUh Ventilation 4 � 2,703.8 BTUh — Excursion adjustment load: 61.4 BTUh Total cooling: 19.138.2 BTUh System Block Load Breakdown-Heating Windows,glass doors.akylWhts: 3,098.2 BTUh _-- Ernebpe(yells,doors,roof.etc.): 18,3ff - - - - Infiltration: BTUh ---- Duct heat kiss: BTUh --- Ventilation/winter humidification:—.-BTUh Hot water piping load: 8TUh Total heating: 39,761.1 BTUh System AED Curve �-Average Gam —Lim Lkv 2.756 2.362 1.968 L 1.575 m 1.181 787 394 - ---� - 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day ACCA-Approved Manual A Calculations 23:31:21 01-27-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual A residential HVAC load calculations. DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT �0 y'Z 12 APPRO D 1540 SULLIVAN AVENUE Bldg.Permit# lG 644-2511 ext. 230 Date Building Inspect r Application must be printed or typed FEE SCHEDULE Location of Job: F $0-$1,000=$15.00 StreetLot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT -Uyf(irA us I �� �� P 1 lY► C� APPLICANT ADDRESS ]:74 01a-1U APPLICANT PHONE# S100 O W N S fq OWNERc�c1c� OWNER ADDRESS �So_�}- = +� OWNER PHONE �o(] C ;D ESTIMATED COST$ uOO. OO � V x, IS THIS A CONTRACT COST? _Yes _No f �G FEE ENCLOSED$ — fYljs TYPE OF JOB: y(Pa R C _New Installation f ZAlteration/Addition/Repair awpo0 Revised 4/01//2002 � 4 1 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION? ❑ YES ❑NO Eln 1 BUSINESS CURRENT USE AND OCCUPANCY t42S IC f\�Q 1 ❑ASSEMBLY Cl MERCANTILE ❑EDUCATIONAL FUTURE USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑MIXED USE (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑ YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK nr THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 1 al� CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLIC DATE y ol7'00l lj A Peart, Dayshell From: vtsdmailer@vt-s.net on behalf of melissa@newingtonelectric.com Sent: Monday, May 02, 2016 11:34 AM To: Peart, Dayshell Subject: [Town of South Windsor CT] Change scope of work for a permit Hello dpeart, Melissa (melissa@newingtonelectric.com) has sent you a message via your contact form (http://www.southwindsor.org/user/126/contact) at Town of South Windsor CT. If you don't want to receive such e-mails, you can change your settings at http://www.southwindsor.org/user/126/edit. Message: We gr t _ f for 3807 Mill Pond Dr. The customer had decided to change .. _kNpAW want to do the panel change with surge protector existing panel an3`ree$'fdRre'�T'ght fixtures. W - � i DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPRO T 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 -F Date Building Inspector • Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$I,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS 12Q 1�)Q X— S nitS!Sy�'U'(, c-T UCnC/ -7 0 APPLICANT PHONE# C2 O — G ' U �C O W N S F,q OWNER C G OWNER ADDRESS a ,r OWNER PHONE 6 G 'Z C = ESTIMATED COST$ �.� IS THIS A CONTRACT COST? ✓ Yes _No FEE ENCLOSED$ 165n f��s O�� TYPE OF JOB: R C _New Installation " Z Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF YATEM: TYPE OF BUDDING: UHI�ATING pRESIDENTIAL C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRES LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC UWARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE�°F INSIDE�°F DIFFERENCE-Z°F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) �Zi4��� GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑OIL-GPM OIL TANK LOCATION :❑ INSIDE❑OUTSIDE CAPACITY TAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING c �1 DESIGN TEMP.OUTSIDE ( Sr OF INSIDE 7 0 °F DIFFERENCE, ' °F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) �v VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. �CJC� `fr�'i `G D - r CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT `�� DATE 7 OCR MAY-7-2008 03:12P FROM:LLEY A/C & HEATING e606580315 TO:18606447280 P.2 RIGHT-J SHORT FORM it Entire House - Valley A/C & HEATING, INC. P.O BOX 494.SIMSBURY.CT 06070-0404 Phone.8804L%.0371 Fax:8e0.858-0315 FAX Project Inf• • For: JOAN WARNICK 2807 MILL POND DR, SOUTH WINDSOR,CT 06074 Phone:644-5546 Design Information Htg Clg Infiltration Outside db(OF) 0 95 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(OF) 70 20 Fireplaces 1 Daily range - M Inside humidity(%) - 50 Moisture difference(gr/Ib) - 16 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Efficiency 80.0 AFUE Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 1006 cfm Actual cooling fan 1006 cfm Heating air flow factor 0.028 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load Sensible heat ratio 91 % ROOM NAME Area Htg load Gig load Htg AVF Clg AVF UP) (Btuh) (Stuh) (cfm) (cfm) FIRST FLOOR 600 18862 8703 519 465 SECOND FLOOR 600 17715 10114 487 541 Entire House d 1200 36577 18817 1006 1006 Ventilation air 0 0 Equip. @ 1.00 RSM 18817 Latent cooling 1806 TOTALS 1200 36577 20624 1006 1006 Sold4tallo values have boon manually ovorrlddon Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrightsoft RlghtSutle Resldamial°'6.0.52 RSR25130 2008-May-07 15:1e:55 CADocuments and SaningsVUI UserslDocumentaWy DocumeMsiWripMsoll WACtSAMPLE.rsr Page 1 S � Electric # APPLICATION FOR BUILDING PERMIT Plumbing HVAC# , Ms' \ id E)6 e — a FDate: J.VL �2 Sprinkler# 12e,�>o 03 2Z) Estimated Cost $ I'a$, 4�5�` FINAL APPRO Permit Fee $_ o2 f 4 S3 Building COMPLETE RED BOXED AREAS Occupancy Fee $ Engineering _ TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit — ► SIGN ON REVERSE SIDE A Appr.for CO. Total Fee $ a y�3 TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $.4737'+b4 The undersigned hereby applies to do work according to the following: Applicant_�e5i,4 .t1nAt.j +! SHX.MP11JL Location of Work.STIQA 'adiD CA,� LotNo. Applicant's Address 1?9 t3' F-AQ Ht L4- -&l-D Tel # 611,91 at 20,S-7 Town W A tM M&&5 I►GH US Zip !f S/ Lic.* ?3&A/ Owner 5TLt-AW31L,dqe- PGS0C.icLjt(-*iJ Architect 4, 1 x- Owvner's Address 26d A M 1 tL +PaD DIL Architect's Address 7-1, (:%4 v gX,Vn W Zip Q{zQ Lr,b c.21ti'�� ��20.KR-. �T Zip 4�93� Sq. Ft.New Area: 1 st Ff. 2nd Ff. P1 3rd Fl. _ _0 Total New Area Purpose of this permit !Rlnoy lNCal� �[ City Water Well .] Septic System _.1 Sewer 020/0P0072(- Ins: HO i P Cert. Area Basement Garage Approved b Date 6 Z Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building an 1 use is allowed. Signed I hereby apply for a Certificate of ccupancy for the ork described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS