Loading...
HomeMy WebLinkAbout0 CELOTEX - PUBLIC WORKS Gannett Fleming GANNETT FLEMING,INC. 150 Wood Road Braintree,MA 02184-2509 Office: (781)380-7750 Fax: (781)380-7754 www.gannettflen-ing.com November 1,2006 Mr. Christopher J. Dougan Chief Building Official Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 RE: Town of South Windsor Public Works Facility Addition 137 Burgess Road Dear Mr. Dougan, We are in receipt of your October 16, 2006 Corrections Notice regarding the subject project. We offer the following information in response to items 4, 7, and 9: 4. Provide sprinkler protection where combustible materials are present above drop ceilings and concealed spaces, (above locker room area, adjacent transition between old/new construction). Response: As discussed in the attached letter from Robt. TV. Hall Consulting Engineers, Inc., we do not believe that sprinkler protection is necessary for the combustible material that was found above the drop ceiling. Based on the standards established by NFPA 13— Automatic Sprinkler Systems Handbook, sprinklers are not required if the heat content of the facing and substrate is less than 1,000 Btu/sf. We have calculated the heat content of the facing and found that it is approximately 200 Btu/sf. 7. Clarification on roof drainage,columns 1-10. 1) Square footage of roof field, ie: 5400 sq. fl vs. 1602 sq. ft, leader size and primary/secondary independently designed. 2) Use 1996 International Plumbing Code. Response: iVe have re-calculated the roof drainage design between column lines I and , 10 based on a 5,581 square foot area. Based on these calculations (attached) two a(J' scuppers are required for the primary roof drain system. We are providing a total of six scuppers for this area. The additional four scupper downspouts are intended to serve as the secondary roof drainage system. 9. Factor snow drift surcharge at high/low roof areas that are relevant to new roof overlay areas per letter to Mike Gantick from Don Nicholas dated Oct. 5, 2006. Response: Included in our calculations of the existing roof dead load is a snow load of 30 pounds per square foot. it'hile surcharges associated with snowdrifts may occur on this section of roof, these are loads that currently exist and, therefore, will not be A Tradition of Excellence Since 1915 Mr..Christopher J. Dougan Page 2 of 2 November 1, 2006 additional loads. The additional member loading results from the proposed roof insulation system that was estimated to be less than 3 pounds per square foot which results in an increase of less than 5%to the roof dead load. We trust that we have satisfactorily addressed your concerns. If you have any additional questions or comments regarding these issues,please feel free to give me a call at 781-380-7750, ext. 5035. Very Truly Yo Thomas P. Da ey, P.E. Project Manager Attachments cc: Mr. Michael J. Gantick,P.E. Mr. Vladimir Tussman Mr. Jon Jackopsik, W.J. Mountford Mr. Wes Gutowski, Robt. W. Hall File(44051) ROBT w. HALL CONSULTING ENGINEERS, INC. 540 MEADOW STREET EXTENSION AGAWAM, MASSACHUSETTS 01001.0002 (413) 789.0960 • FAX(413)789-3295 -November 1, 2006 Thomas Dailey,PE Gannett Fleming 150 Wood Road Braintree,MA 02184 Re: South Windsor DPW Protection of Combustible Materials Above Ceilings Dear Thomas, We have reviewed the requirements of NFPA 13 in regards to the presence of vinyl insulation facing in concealed spaces. Section 8.14.1.2.12 of NFPA 13 (copy attached) addresses this situation. The standard states that if the heat content of the facing and substrate is less than 1000 Btu/sf sprinklers are not required. This insulation is vinyl faced. We calculated the heat content of the facing and found that it to be 201 Btu/sf. Based on this we do not believe sprinkler protection above the ceilings is required. Our calculation and data on the vinyl facing is attached. If there are any additional questions don't hesitate to contact me. AF ,. Griffi s,P 286 NFPA t 3/Chapter 8 • Installation requirements 1 Ar:y o°these scenarios coziid be found to a concealed space. It is imperant to recognize v, that coaceaicd spaces are not exclusi;e1�•luralec to areas above ceiLrgs but can also be found r in walls and is spaces beneath the floor.For example; a raised floor in a computer room 1s a er concealed space. If none of Zhe three prescribed conditions exists, the ;pace is defined as a concealed; noncembu;Cble ;pace with respect to combustible objects and requires no add. 8 tional sp:initler protection. _tic Some minor quantifies of combustible r~aterials, such as cemmuricaeon wiring, can be "` present in some concealed:paces but should not topically be viewed as requiring sprinklers eC see 8.14.1.1). The threshold value at which sprinklers become necessary in the concealed :'10 space is not defined.For example,the usual amounts of data or telephone wiring found above qt a ceiling would not typically constitute a threat.If bundles of unsheathed computer wiring are installed above the ceiling or beneath the floor in a manner where fin propagation in all'direc. Y ' lions is Likely, then the concealed space should be treated the same as a combustible space, thereby requiring appropriate sprinkler protection. If some ocher protection measure is pro- Tided, such as a CO2 system, then the concealed space is considered to be protected, and J l sprinklers are not required. 8.14.1.24 Concealed Spaces Not Requiring Sprinkler Protection. A.S.14.1.2 Subsections 8.14.1.2.3; 8.14.1.2.4,and S.I o not require spri I-T protec- t:.,u because it is not physically practical to install sprinklersibility of uncontrolled fire spread,con- in the types of concealed spaces discussed in these three exceptions.To reduce the possibility sideratiou should be given in these unsprinklered concealed space situations to using 8 14.1.2.7, 8.14.1.2.10,and 8.14.1.2.12. The subparagraphs of 8.14.1.2 indicate conditions where sprinklers are not required in spaces ' that would normally require sprinklers. Sometimes the building is modified to meet one of, these exceptions to avoid installing sprinklers in the space.Not all of these exceptions provide an equivalent level of fire safety,because some of the exceptions simply recognize that the in- stallation of sprinklers in the space is not physically practical.This difference in level of fire safety is especially true of 8.14.1.2.3, 8.14.1.2.4, and 8.14.1.2.5, which primarily exist t6 cover situations where sprinklers are retrofitted into existing buildings. 8.14.1.11 Noncombustible and limited combustible concealed spaces with no combustible---- loading having no access shall not require sprinkler protection.The space shall be considered a concealed space even with small openings such as those used as return air for a plenum. 8.14.1.2.2 Noncombustible and limited combustible concealed spaces �•ith limited access and not permitting occupancy or storage of combustibles shall not require sprinkler protec tion. The space shall be considered a concealed space even with small openings such as those used as return air for a plenum. Paragraphs 8.14.1.2.1 and 8.14.1.2.2 were added to the 2002 edition to address an ama other exceptions were not clearly stated in previoas editions. These new paragraphs permit the omission of sprinklers from nencombust:ble or limited combustible concealed spaces havir4 no combustible loading and.united or no access. These spaces are pe--r med to ha,.e s,-nj , openings such as zhcse used for return air plenums and still be considered a concealed space. 8.14.1.2.3 Concealed spaces formed by studs o_joists with less than 6 in_4'152 ram)between } the inside or near edges of th=studs o:joist;shall not require sp.:nkler pr oteczto:t.i See Figure F..54.1.c 1.) 8.14.1.2.4 Concealed spaces formed by bar;oists A•ith less than 6 in. (152 I=', between� a roof or floor deck and ceiling shall net require sprinkle;protection. 8.14.1.2.5 Concealed spaces formed by cei:n2s attached dur•dy to or withir.6 in '152 t•-0) Of wood foist tors-=,-don shad no.reLTulre sprinkler protection. 2OC2 Autornabc Sprinkler S�,stems Handbo29 288 NFPA 13/Chapter 8 • Installation Requirements The requirements of 8.14.1.2.10 permit the use of lituited-combustible materials as a ut lute for spnn)Jer protection. «ben ccrside:in;these materials. it is important to ve ifv thy, r the testing used to detettnine the material's combustibilit}• was conducted ;A•ith ;he — o a.;auged in the position in which it urU be Installed. Changes in thMaceri4 ment of the Material car sigrlifi;anti} change the flames e orientation or a,'ra pread characteristics and the combus_ tibilin of the material.Additionally,;hc matcrials are required to be rigid because experiene, indicates that nonrigid raterials do rot demonstrate the same characteristics druing a fin, p: 8.14.1.2.11 Concealed spaces in which the exposed mazes are constructed entirely of Sri._` $ retardant treated wood as defined by NFPA 703.St n&rd for Fine Rerwdant Im re $and Fire Retardant Ca I r ud i?., ;l1Q,ericls: shall not requite sprinkler protection.` Rood^ $ [71,eI4.1.2.12 Noncombustible concealed spaces having exposed combustible insulation where o. heat content of the facing and substrate of the insulationmaterial does not exceed Bnu'ft2(11,356 kJ,m2)shall not require sprinkle.protection. ti graph B.14.1.2.I2 alloWs the use of paper-coated insulation material in a space that is oth. 0 e defined as a noncombustible space. p 8.14.1.2.13 Concealed spaces below insulation that is laid directly on top of or urtbin the ceiling joists in an otherwise sprinklemd attic shall not require sprinkler protection. Paragraph 8.14.1.2.13 indicates that sprinklers are not required in the space between the insu- lation in an attic and the ceiling sheathing.The sprinklers in the attic are anticipated to pro, t` ide spfficient protection. 8.14.1.2.14 'I'ertical pipe chases under 10 ft2 (0.93 m2), where provided that in mul .': buildings the chases are fire stopped at each floor using mate tifloor rials equivalent to the floor con_ struction, and where such pipe chases shall contain no sources of ignition, piping shad be noncombustible,and pipe penetrations at each floor shall be properly sealed and shall not re- quire sprinkler protection. , Paragraph 8.14.1.2.I4 is included in the standard due to the impracticality of installing spanIM - klers in the small spaces that are usually behind the walls of bathrooms and kitchens in rrb ec dential facilities.This reqesi- uirement supports the premise that sprinklers can only be omitted in concealed spaces where the installation of s nnkl 8. as those spaces identified by 8.14.1.2.3, 8.14.1.2.4, and 8.14 112.5 or wherectombustibles or ignition sources will not be present. br ! 8.14.1.2.15 Exterior columns under IO ft2 in area formed b studs or wood joist, supporting '.Jo exterior canopies that are full y 1 y protected with a sprinkler system,shall not require sprir der protection. �'_.'A 8.14.1.3 Concealed Space Design]Requirements. Sprinklers in concealed spaces ha�-ing no T� access for storage or other use shall be installed in accordance with the requirements for light hazard occupancy. cc The sprinkler recui-ernent in 8.14.1.3 applies to a concealed combustible space that requires sprinkler prot--lion because of 8.14.1.1. The reference to Hight hazard occupancy is for the Purpose of selecting a density or the appropriate pipe schedule table (if allowed is Chapter 11).The type of construction must be evaluated to determine what area of cove age is needed �f for the sprinklers. need The intention of 8,14.1.3 is not to r5quire sprinklers ir,a concealed noncombustible spaCc w'$ that contain_ mechanical -ouipment made Of noncombustible Irate~als. Nor is tie intent to require sprinklers simply because an access anel is ' az ' The cxistence of an access pariei to a c oncealed;pace c�u Couldlead ate the pace being ed.`.or stn:age or ot'Ier purposes. Hocvevt If the size o;arrangament of the access is such tha;the space cannot or will not be utilized and tae co;nbustibrl;ty Is limited to the combustible a, 2002 Automatic Spnnider Systems Handbook A E✓T"+� Robt W. Hall Consulting Engineers Job Inc. Locatlo00, _ 540 Meadow Street EXt ' Sheet No. of Agawam, MA 01001 Calculated By ate _ Phone: ,'413) 789-0960 Fax: (413)789-3295 Chacked By bate I 4 Scale , I i I � I I i I l i I I 1 1 I ' 1 I 1 t--t-•-r••- ( 1 - I . 1 I I I T__- ( i �� I I - •� � c.�-•-- --�—I I I I I � i I - -Ix I I _7 I I I I ILj I1- -�1 I i f I I I t--- 1 • ' �___j...___ I _1 _ IL 1 ' I 1 1 1 I I ; I I I � -I- •I----{---1 r- ; • ; 19 �?L !_,rth;j .' 'ti��Sl:a'1� !';''+<F I �nn� I cord rc its 1011 Occsscd from molten state to an incombustible h0ious form �tt Y'` ,' r"" • ASTM C "S REQUIREMIENTS INCLUDE THE FOLLOMIIN T rdita '� �,1'u ► ,` •. � �►, ,„, G EST METHODS: r_. 3'tl and C 653-Thurm !R a e..hs.anc< s.� ; -Surface g ASTM E 0 Critical Radiant Flux ar. Meter Vapor Permeance . ta'' r, •f� K-43U4 Oder Emisvon SECT 13.5 Corrosiveness "• a ASTIV.C TM --Fungi Resistance ASTM C'I D• •Water vapor Sorption k r�J Rf' r., ��*TM C 764 REQUIREMENTS INCLIJOE THE FOLLOWING TEST MiTHoo& - _qWAM C 518 and C 687•Thermal Resstance (R-vawe) 1�75d •tMAlled Thickne" ASTM E 136 Combustion Characteristics AS��.E P70 .Critical Radiant Flux _ f -�8�4 Water Vapor Sorpton • AS-M C 1304 Odor Emission • - ��2.�7 - corrosiveness SECT4, 1+t _ 9 S - Covers e .�. Fyngi ReststenGe a1f20. }. • VNiACE D INSULATION MARKINGS: �-�s printed on the face of the product, 'A""W-WA% TS LABORATORIES: '�• ry .,, Biftt7616nket3 BZJZ/BKNV Restive Design. aSti `—A&WTIONAL CERTIFICATIONS: VI Miami-Dade Coo Flaride �Y. Code compliance for - LblaMtet,andtoose•hij,No.00-000 06 ��a ass City of New York,Department of Buildings Code t Compliance for unlaced fiberglass thermal insulation ;` 4{ code*ediurs 27-232 0,V 27 348 110011-00-bust,biMfy. Stale of C611f0mil Bureau of Houle Furnishings am T►,ermal In sulation certified product listing Ifccnsc ITA1275. Conhpliarnt with Of)-of Los Angeles,California t • A ' r requirements for thermal Assulatlons Minnesota In6ulatlon Standardf:Program National Standard of Canada CANWLC•S702-g7 �' .;s• 'or preformed and loose-nn InstJlations. (tp ,,• at:'' Nptiahy pccearch CouruJl Canada CCMC Eva,uation . .1• .^.,q,..F " --1� :. 1101n95 for Gatti and l000e-fin DESCRIPTION: FORPLAX AD363 Villrl Vapor Retarder Film TYPICAL PHYSICAL PROPERTY VALUES F& ff ProduM Inc. 425 L.•tglc kook Avenue rRopERTres vAr,1iF.S Tu-S l•lMul-11on Rose:..%A.New iar.,tl;y Thlclulcas, Ll lts 0014;i. ASTM D.1591 USA 0700 Yield,sq A& 43 R t/-S% 1.226 54$d s4 Dclt:rtrunctl by wcigbl Tel: Bntticncu Tcmperature, 'F t 57 ASfM U-17,Af r„A:973.226.545v T ensue Strength,PSI MD 2400.2E(1h Enuul:infoQehp-bta.Crtrn CU I`1W-24UU ��b-t382 wcb:chp-waxotn ElonpAtlot4% MD 1510 ASTM D-KKZ M 140 Tear Strength.Gratnsllnil MD 1515:11 ASTM D-689(Elnlcrltlarf) CU loo-uo Light Re1i:ct,vilti,%. 1(Niv/.,,�0% ASTM C-S23 WIVC Lctlgllt 44o.70o Perm==ofFilnl,V.S f'MM 1.0 ASTM E-X(Metl►od A) U.L.FIRE HAZARD CLASSIFICATIONS: Official U.L blltn of AD363 filtu 1`13rne SpMd 15 ASTM E.lt4 r Smoke Developed 90 o UL-723 Official U.L.composite bum Raff Smoke S Developed 25 50 ASTM E-84 or UL-723 Snlake Developed St1 I JM 1TED WAt.RRANTY FnrplaK Fsntpn I,tC (F't.l),I,.L,h,11.\tiw.,Jt..v.rc.ri,w.lW N:,WYU PLiali , ,..01 w„rt,m+n•.Mp..hvt t.ud u+rw.urrlrnc , P(NYPCI �tYl C wR?Mt!t:el then ite n1kJ Jaia will on.y rcrdnaa For('Mic�1D14;film wh,,-h =y\„ Dour talutact, Gee from defe:U in/1:.1°rcJ days of deirvcry without chine 1)Ct¢v:F•>I daft are rcnugo.y,J. ,:qq,„hw tl.ly r.y on to he dcroatvv well.tli W411IUKY NYPC dean nal iw Down+nd the u.a of Ihv.1,.,.. mauled_of mxq!or any kind.OurrlCovcrO r".•dn.a. (I j•n,t.4 ,(Zj m h,g11 l'�'CM1nm li Mtn t by this,✓Ruled or tlhen attached. (�j under tegy+ti atyrt t,elow 1C7. 77ty rwctvti„,rK.autw.add,an"re n•i 6 y't�e'nrlronmttlt w,Lllout L'V Icriw% -If u•a.0 a l,av, 11),.,.mn of of+vha,,e8 ( ) fu b<lwuirucd a warrlttnee of Shy Kind Scat tultdly�a r'�\•'i•,a.nr+r.+„mal F\Iht rctt 1cllha Fhl nor NY PC will Iu valt,t ofthc produatc ?So uler repreoe mNia,agrnl,w&,trib s sut utnt,il,.w:7.J to vev..,e,,,,v rcapuntihla fur d^itttr beyond the pw;JI"t tunuev 1,2tlr1Z wwtrvtttoo ur wnrrerlty Dcyvnd 111c ohovc lcrme �,: c�a•-�17C'r11� � j''�C� 1��iiifiJ: 'i i�1Sl�y� iV`'l= ii� frirl' I �•)IJ c 1 SUBJEQT J VI�,)i�',r R t I; 11 i r 'rl�( �' SHEET NO � OF�_ • LI Gannett Fleming Pr11 JI ` n, JOBNO. BY 7 DATE 9':2!'h HKD 8Y DATE 1"('Or-, J.nCxl �o� ��r►,<< I �).,�� � ��.,,�,� b;,,r (�� �e �a� � a., 1 ��'6 1 F3 IIO� S�a,�S ��`c4 ►�e I� ���qc i,n�f�y t �' r ra 1 areq Arfoa = HOB X �1' �{�' = � a`J'J. � Si Fc'o�► G Dl e 1 0� 2 �ke Y� ' FGlly pr fie Qrer, o 4►-^e let- l r /a c a:�3cx',4 e , c.'� d' 4 r-e �" f Ci:+� Il,�r��cse �. SCv�pe�� arc r,�ee 0r ��' ,rc' v\�ai1 c4ev1 ' are • �ror� Cod For � O �� ��e Sc�P�Q,r � ✓ er do d. �P awe 1. 11 U rJ �� 5CC 1:Ors 12e��5e � C 5c e Srti � N.o, 2 • !� ," Gannett Flemin �DAT U� SHEET NO 2 OF Z BY JOB NO DATE Cc{ IcuIc' � pAw't� f ly5'- 8 5S1z g ;- i vie 10 _ 58) �F Ck OC15 }c C ^� �� ,`�r;Z"� y Ire' •ec leq�c �! a 3 ,4Mc e� )ea r ',s 25 )o r � 2 3�sF ) 7 7. �cuP�r� are red�;r-e 7o'r Pr.r-�ry rocS WC are frLa ; he,.) Jc,> Pars q SOWN SEA C � Z � 719v� 0 S 1540 SULLIVAN AVENUE• SOUTH WINDSOR, CT 06074 `~OSOR-CO�r TELEPHONE(860) 644-2511 November 16,2006 Mchael Gantick Director of Public Works 1540 Sullivan Avenue South Windsor, Cr06074 Re:Town garage- Foam plastic I am in receipt of your written notice,dated November 16,2006,to cover exposed foam plastic at the Town Garage.The product for this purpose is affixed to your notice and should satisfy requirements of the State Building Code,IBC 2003,Section 2603.4. Christopher J.Doug Chief Building Cffic' Cc:Karl Reichle,Supt.Of Parks &Grounds Melvin C.Stead,Jr.,Supt.Of Streets i MEMORANDUM November 16, 2006 TO: Chris Dougan, Chief Building Official SUBJECT: TOWN GARAGE—CELOTEX Per our conversation of November 14, 2006, we are proceeding with covering the Celotex insulation with a FB 30 product to address your concerns. Attached is the specifications sheet. Michael J. Gantick, P.E. Director of Public Works MJG:bmr Attachment cc: Karl Reichle, Supt. of Parks & Grounds Melvin C. Stead, Jr., Supt. of Streets I c::C:)M I mp'=W= FB 30 0,0 FZP0 RAT ION Product Information PRODUCT STRUCTURE DIMENSIONS COMPONENT DESCRIPTION ENGLISH METRIC Finish Side Substrate Aluminum Foil 0.0003 inch 7.6 micron Adhesive Flame Retardant High Performance Machine Direction Reinforcing Fiberglass 2 finch 12 mm spacing Cross Direction Reinforcing Fiberglass 3 finch 8 mm spacing Back Side Substrate Natural Kraft 30 lb./3000 sq ft 49 /s .m PHYSICAL PROPERT IES TEST METHOD MEASUREMENT/RESULT I ENGLISH METRIC Permeance ASTM E96,Procedure A 0.02 perms f.15 n /s .m)s)Pa Puncture Resistance TAPPI T803 25 Beach units 0.75 Joules Machine Direction Tensile Strength ASTM D828 Modified 40 Ibfinch 7.1 kg/cm Cross Direction Tensile Strength ASTM D828 Modified 30 lb./inch 5.4 kg/cm Burst Strength ASTM D774 40 psi 2.8 kg/sq.cm Mold and Mildew Resistance ASTM C1338 no growth of organisms Humidity Resistance ASTM C1248 no corrosion or delamination Dimensional Stability ASTM D1204 @ 150-F 65°C does not exceed 0.25% change Low Temperature Resistance ASTM C1263 Modified -41 de .F -41 deg.0 High Temperature Resistance ASTM C1263 Modified +240 deg.F +115 deg.0 Emissivity ASTM C1371 0.03 Thickness,Nominal Micrometer at Thickest Points 6.5 mils 165 microns Weight Per Area Scale/Balance 20 lb./1000 sq.ft 98 g/sq.m FIRE RESISTANCE PROPERTIES TEST METH OD MEASUREMENT/R ESULT Flame Spread* UL 723/ASTM E84 10 foil side 30 paper Smoke D'velo ed• UL 723/ASTM E84 0 foil side 5 paper Metal Building Composite SBC' UL 723/ASTM E84 25 flames read/50 smoke developed" This product meets or exceeds the requirements of ASTM C1136, type II,IV Properties and parameters are typical,subject to change without notice, and not intended as product specifications. Weights and thicknesses are nominal,with+10%tolerance. 'Indicates Underwriter's Laboratories classified products."With classified adhesive and application rate.U.L.File No.R4461. Sheet No.:PIS-110 Revision No.:3 Date:7/29/03 WARRANTY:ALL COMPAC products are produced under controlled quality standards and are warranted to be free from defect In material and workmanship.Any material shown to our satisfaction to be defective within 30 days of delivery will be replaced without charge. COMPAC CORPORATION will not be responsible for claim beyond replacement of the material sold.All products are sold with the express understanding that the purchaser will independently determine the suitability of the material f r the purpose for which they are purchased.Recommendations by COMPAC CORPORATION are not to be oDnatrued as warranties of any kind.No salesman,representative, r agent of COM PAC CORPORATION is authorized to give any guarantee,warraniyr to make any representation In addition to,or contraryto,the foregoing. COMPAC CORPORArIONs P.O.Box 98, Old Flanders Road, Netcong,New Jersey 07857 973/347-3900•US&Canada 800/631-9347 or 800/631-9350 Fax No.973/347-4634 CHAPTER 26 PLASTIC SECTION 2601.0 GENERAL Plastic roof panels: Plastic materials which are fastened to 2601.1 Scope: The provisions of this chapter shall govern the structural members,or to structural panels or sheathing,and design, construction and quality of light-transmitting plastic Which are used as light-transmitting media in roofs. i materials and foam plastics. Section 2601.0 shall apply to all Plastic wall panels: Plastic materials which are fastened to structural members,or to structural panels or sheathing,and light-transmitting plastic materials and foam plastics. Section which are used as light-transmitting media in exterior walls. ! 2603.0 shall only apply to foam plastics.Sections 2604.0 through Reinforced plastic,glass fiber:Plastic reinforced with glass 2608.0 shall only apply to light-transmitting plastic materials. fiber having not less than 20 percent of glass fibers by weight. 2601.2 Approved materials:The use of all plastics that conform Thermoplastic material:Aplastic material which is capable to the strength,durability,sanitary and fireresistive requirements of being repeatedly softened by increase of temperature and of this code and ASTM D635,D1929,D2843 and E84 listed in hardened by decrease of temperature. Chapter 35,shall be permitted subject to the limitations of this Thermosetting material:Aplastic material which is capable chapter. of being changed into a substantially nonreformable product 2601.3 Application for approval:Applicants for approval of a when cured. Ylastic material shall furnish,in accordance with Section 1704.0, SECTION 2603.0 FOAM PLASTIC fall necessary technical data required by the code official. The 2603.1 General:The provisions of this section shall govern the data shall include,if necessary,chemical composition;applica- ble physical, mechanical and h requirements and uses of foam plastic in buildings or structures. p y thermal properties, such as fire- resistance, flammability and flame spread; weather resistance; 2603.2 Labeling:Foam plastics or their packages of foam plas- electrical properties;products of combustion;and coefficients of tics,and containers of foam-in-place plastic system ingredients, expansion. shall be labeled in compliance with Section 1704.3. 2601.4Identifying mark:All plastic materials approved for use 2603.3 Surface-burning characteristics: Unless otherwise in- under this code shall be identified by the trade formula number dicated in this section,all foam plastic and foam plastic cores of or name or other acceptable identifying mark applied to each unit manufactured assemblies shall have a flame spread rating of not or package. more than 75 and a smoke-developed rating of not more than 450 when tested in the maximum thickness intended for use in 2601.5 Interior finish and trim:Light-transmitting plastic ma- accordance with ASTM E84 listed in Chapter 35. terials installed as interior finish or trim shall comply with Section 803.0. Foam plastics shall only be installed as interior Exceptions finish in accordance with Section 2603.8.Foam plastics installed 1. Smoke-developed ratings for interior trim as provided as interior trim shall comply with Section 2603.7. for in Section 2603.7.4. 2. Flame spread ratings for exterior wall installations as SECTION 2602.0 DEFINITIONS provided for in Sections 2603.6.3 and 2603.6.8. 3. Flame spread and smoke-developed ratings for roof 2602.1 General:The following words and terms shall, for the applications as provided for in Section 2603.4.1.5. purposes of this chapter and as used elsewhere in this code,have 4. Where foam plastic is tested in a thickness of 4 inches the meanings shown herein. (102 mm)and is used in a thickness of greater than 4 Plastic inches(102 mm)up to 10 inches(254 mm),the building Light-diffusing system: A suspended construction consist- shall be equipped throughout with an automatic sprin- ing in whole or in part of lenses, panels, grids or baffles klers'rstem in accordance with Section 906.2.1 and the suspended below independently mounted electrical lighting foam plastic shall be protected by a thermal barrier. sources. E2603.4mal barrier: Except as provided for in Section Plastic glazing: Plastic materials which are glazed or set inoam plastic shall be separated from the interior of frame or sash and not held by mechanical fasteners which pass an approved thermal barrier of 'A-inch (13 mm) through the glazing material. oard or equivalent thermal barrier material which 279 THE BOCA NATIONAL BUILDING COOE/1996 721.7.2.1 Use Group R: In occupancies in Use Group R, 7223 Noncombustible furring: In buildings of Types 1 and 2 I in attics, mansards, overhangs or other concealed roof construction, plaster shall be applied directly on concrete or spaces,draftstopping shall be installed above,and in line masonry or on approved noncombustible plastering base and with,tenant and dwelling unit separation walls that do not furring. extend to the underside of the roof sheathing above. 722.4 Double reinforcement:Except in solid plaster partitions, Exceptions or where otherwise determined by the prescribed fire tests, I. Where corridor walls provide a tenant or dwell- plaster protection more than I inch (25 mm) in thickness shall ing unit separation, draftstopping shall only be be reinforced with an additional layer of approved lath embedded required above one of the corridor walls. at least-/4 inch(19 mm)from the outer surface and fixed securely 2. Flat roofs with solid joist construction are not in place. required to be provided with draftstopping over 7225 Plaster alternatives for concrete:In reinforced concrete tenant and dwelling unit separation walls if the construction,gypsum or portland cement plaster is permitted to joists form a draftstop. be substituted for 1/2 inch (13 mm) of the required poured 3. Draftstopping is not required in buildings equipped throughout with an automatic sprinkler concrete protection,except that a minimum thickness of 3/8 inch system installed in accordance with Section (10 mm)of poured concrete shall be provided in all reinforced 906.2.1 or 906.2.2, provided that automatic concrete floors and I inch(25 mm)in reinforced concrete col- sprinklers are also installed in attics, mansards, umns in addition to the plaster finish.The concrete base shall be overhangs and other concealed roof spaces of prepared in accordance with Section 2506.0. combustible concealed space. SECTION 723.0 THERMAL-AND SOUND-INSULATING MATERIALS 4. Draftstopping is not required in detached one- and two-family dwellings. 723.1 General:Insulating batts,blankets, fills or similar types 5. In occupancies in Use Group R-2 which do not of materials—other than fiberboard,cellulosic and foam plastic exceed four stories in height,the attic space shall insulation—including vapor retarders and breather papers or be subdivided by draftstops into areas not ex- other coverings which are incorporated in construction elements, ceeding 3,000 square feet (279 m2) or above shall be installed as required by this section.Fiberboard insula- every two dwelling units,whichever is smaller. tion shall be installed as required by Section 2309.0,cellulosic insulation shall comply with Section 723.5, and foam plastic 721.7.2.2 Other use groups: Draftstopping shall be in- insulation shall be installed as required by Section 2603.0. stalled in attics and concealed roof spaces,such that any horizontal area does not exceed 3,000 square feet(279 m2). 723.2 Exposed installations:Such materials,where exposed as installed in rooms or spaces,including attics and crawl spaces of Exceptions buildings of any type construction, shall have a flame spread I. Flat roofs with solid joist construction are not rating of 25 or less and a smoke-developed rating of 450 or less required to be provided with draftstopping over when tested in accordance with ASTM E84 listed in Chapter 35. tenant separation walls if the joists form a draft- plenum installations shall comply with the requirements of Sec- stop. tion 2805.0 and the mechanical code listed in Chapter 35. 2. Draftstopping is not required in buildings equipped throughout with an automatic sprinkler 7233 Concealed installations:Insulating materials,where con- system installed in accordance with Section cealed as installed in buildings of any type of construction,shall 906.2.1 or 906.2.2, provided that automatic have a flame spread rating of 75 or less and a smoke-developed sprinklers are also installed in attics and other rating of 450 or less when tested in accordance with ASTM E84 concealed roof spaces of combustible construc- listed in Chapter 35. tion. 7233.1 Facings: All vapor retarders, whether integral or 721.8 Ventilation: Ventilation of concealed roof spaces shall be applied separately,shall be installed on the warm side of the maintained in accordance with Section 1210.0. building element,and shall have a permeance not exceeding 1 perm.Where insulation materials are installed in concealed SECTION 722.0 FIRERESISTIVE REQUIREMENTS FOR PLASTER spaces(such as wall,floor or ceiling cavities),attics or crawl spaces in buildings of TI pes 3,4 and 5 construction,the flame 722.1 Thickness of plaster:The required thickness of fireresist- spread and smoke-developed rating limitations do not apply ance rated plaster protection shall be determined by the pre- to facings,provided that the facing is installed behind and in scribed fire tests for the specified use group and type of substantial contact with the unexposed surface of the ceiling, construction and in accordance with the provisions of Section floor or wall finish. 2505.0 for.interior plastering and Section 2506.0 for exterior plastering.The thickness in all cases shall be measured from the 723.4 Loose-fill insulation testing:Loose-fill insulation which requires a screen or artificial support for the test arrangement face of the lath where applied to gypsum lath or metal lath. required in the test tunnel of ASTM E84,listed in Chapter 35, 722.2 Plaster equivalents: For fireresistive purposes, 1/2 inch shall be tested in the following mounting method. Loose-fill (13 mni).of unsanded gypsum plaster shall be deemed equivalent insulation shall be placed on the floor of the ASTM E84 test to 3/4 inch(19 mm)of one-to-three sanded gypsum or I inch(25 tunnel in a thickness of 57 mm t6 mm for the length of the tunnel. mm)of portland cement sand plaster. A specimen, including density, shall be representative of the I 82 V� SHEATHING MATERIAL CONTENTS NOT OVER 2,000 SO.FT. ISSUE NO.3204 SURFACE BURNING CHARACTERISTICS FOIL,SCRIM-KRAFr KRAFr exPOSED FOIL EXPOSED Flae Spread............... 30 10 m smoke Developed........ 5 0 .. COMPIAC FLAME-RETARDANT VAPOR BARRIER COMPAC CORPORATION HACKETTSTOWN,NEW JERSEY 07840 MADE IN U.S.A. P/N:11874H PRINTED IN U.S.A. r MEMORANDUM November 13, 2006 TO: Chris Dougan, Chief Building Official SUBJECT: TOWN GARAGE— THERMAX SHEA TING Please find attached information from Celotex on the subject matter. The surface burning characteristics from UL on the product is 20 for the flame spread and 80 for smoke development. The product that is remaining is also in sprinklered areas. Please advise as soon as possible if the above and attached information resolves your questions. Thanks. r Michael J. Gan ick, P.E. Director of Public Works MJG:bmr cc: Melvin C. Stead, Jr., Supt. of Streets Karl Reichle, Supt. of Parks &Grounds Attachment THIRD PARTY INSPECTIONS/COMPLIANCES REGIONAL SALES OFFICES THIRD PARTY INSPECTIONS SBCCi:Southern Building Code Congress -- International.Compliance Report No.9574A 7Q0 CumbAriand Parkwtry A reliable Indication of an Insulating and Standard Building Code,Sect.2603. Jguite 550 materials quality and dependability Is In Canada,the following apply to Thermax Ifill GA 30339 the third party Inspection labels It carries. Sheathing: 'hone{770)4,5 6000 THERMAX®SHEATHING CCMC:Canadian Construction Materials Q0 952-9978 Fox(770)438 8 Subject to the imitations Centre. Evaluation Report No. CHICAGO,tl of approval as Interior I CGSB:Canadian General Standards Board, ouhy'gffic2 PiazC insulation wall and celing CAN/CGSB 5126 M86 400 E,Touhy Ave panels when installed as `' - u described In the current APPROVED Type 1, ?te 225. edition of the FMRC Approval Guide. FHA Federal Housing Administration ,es Plaines t'inois bOCI ThWMU Sao s.rw Promro+. Minimum Property Standards. UNDERWRITERS LABORATORIES INC® Thermax Sheathing comples with ASTM 85 5(321 Frnr{847>8 4 CLASSIFIED C1289, Type I, Class 2 and Federal '`'" zePa INCINNAT{ OH FOAMED PLASTIC Specification HHa-1972/1,Ckas 2. SMACE BURNING LHARACrERIMICS4{33 Kerivlooc3 R' Characteristics, properties or perfor- mance of materials manufactured by Celotex Corporation herein described are derived from data Yl411Y,411t1 l4 Ttl f4\Itl . nT1+1 obtained under controlled test condi- .... tions. Celotex makes no warranties, a.r.yr,.ruALDO CLASSIFIED FOR express or Implied,as to their characteris- INSULATED WALL-CEILING CONSTRUCTION ties, properties or performance under CLASSIFIED AS TO FIRE DAMAGEASILTY ONLY any variations from such condttions (FOR ALUMINUM FOIL-FACED BOARDS ONLY) In actual construction. Celotex ALSO CLASSIFIED FOR WALL-CEILING CONSTRUCTION Corporation assumes no responsibility for CLASSIFIED the effects of structural movement. WITH REGARD TO FLAME PROPAGATION AND DAMAGEABILnY UNDER SPECIFIED ROOM FIRE CONDITIONS ONLY Any deviation from these Instructions voids all warranties including Impled warranties of merchantability and fihtass for a particular purpose. Warning: Celotex* Thermax" products should only be used In strict accor- Thermax Sheathing is protected by one dance with Celotex Application or more of the following U.S.Patents: Instructions. When Thermax products 3,903,346 4,028,158 4,169,921 4,346,133 are used alone or used with non-com- 3,940,517 4,043,719 428083 4,386,983 bustible building components,they will 4AI1,949 4,572,865 RE30984 burn if subjected to a fire of sufficient intensity,but will not contribute to the Additional Information rapid spread of fire.Thermax products Further Information concerning the and other insulations,when used with products, systems, and test methods exposed combustible materials may described in this publication can contribute to the rapid spread of fire. be obtained by contacting Celotex All common building materials like Corporation, Tampa, or one of its wood and Thermax Insulation products Regional Sales Offices. MANUFACTURING PLANTS release toxic smoke if ignited. The systems in this book are for illustra- COMPLIANCES tion purposes only. The structural Integrity of such systems Is the responsi- CABO: One- and Two-Famly DweBng bility of the design engineers, archi- Code,Sect.317. tects, component manufacturers, BOCA: Building Officials and Code applicators and erectors. Administrators International, Inc. Research Report No.94-2 and National Building Insect Damage:In environments where Code,Sect.2603.0 insects and rodents are prevalent,reg- ICBO: International Conference of ulor extermination of pests Is recom- Building Officials, Evaluation Report NO. mended to prevent damage to the 3223 and Uniform Building Code,Sect.2602. insulation. no responsibility to,any errors that may inadvertently appew in this document. Celotex and Thermax are registered trademarks of Celotex Corporation. g- x 7 EXPORT CELOTEX CORPORATION POST OFFICE BOX 31602 TAMPA,FLORIDA 33631 www.celotex.com Form No.3250-1095 Rev. B 3/98 Printed in U.S.A. FIRE-RESISTANCE-RATED CONSTRUCTION N � v plaster alternatives for concrete.In reinforced concrete than 0.12 watt per square centimeter when tested in accor- ttuction,gypsum plaster or Portland cement plaster is per- dance with ASTM E 970. to be substituted for 0.5 inch mm)of the required 719A Loose-5ll insulation. Loose-fill insulation materials concrete protection,except that at a a minimum thickness of that cannot be mounted in the ASTM E 84 75 inch(9.5 mm)of poured concrete shall be provided in re- apparatus without a orced concrete floors and 1 inch(25 mm)in reinforced con- screen or artificial supports shall comply with the flame spread columns in addition to the plaster finish.The concrete base and smoke-developed limits of Sections 719.2 and 719.3 when be prepared in accordance with Section 2510.7. tested in accordance with CAN/ULC S 102.2. Exception: Cellulose loose-fill insulation shall not be re- SECTION 719 quired to comply with this test method,provided such insu- THERMAL- AND SOUND-INSULATING MATERIALS lation complies with the requirements of Section 719.6. 719.1 General.Insulating materials,including facings such as 7195 Roof insulation.The use of combustible roof insulation vapor retarders and vapor-permeable membranes,similar cov- not complying with Sections 719.2 and 719.3 shall be permit erings,and all layers of single and multilayer reflective foil in- ted in any type of construction provided it is covered with ap- sulations,shall comply with the requirements of this section. Proved roof coverings directly applied thereto. Where a flame spread index or a smoke-developed index is 719.6 Cellulose loose-fill insulation.Cellulose loose-fill insu- specified in this section,such index shall be determined in ac- lation shall comply with CPSC 16 CFR,Part 1209 and CPSC cordance with ASTM E 84.Any material that is subject to an 16 CFR,Part 1404.Each package of such insulating material increase m flame spread index or smoke-developed index be- shall be clearly labeled in accordance with CPSC 16 CFR,Part yond the limits herein established through the effects of age, 1209 and CPSC 16 CFR,Part 1404. `: moisture,or other atmospheric conditions shall not be permit- 1; ted, 719.7 Insulation and covering on pipe and tubing.Insula- tion and covering on pipe and tubing shall have a flame spread . Exceptions: index of not more than 25 and a smoke-developed index of not I. Fiberboard insulation shall comply with Chapter 23. more than 450. 2. Foam plastic insulation shall comply with Chapter 26. 3. Duct and pipe insulation and duct and pipe coverings SECTION 720 and linings in plenums shall comply with the Interna- PRESCRIPTIVE FIRE RESISTANCE tional Mechanical Code. !?I 720.1 General.The provisions of this section contain prescrip- 719.1.1 Urea-formaldehyde insulation. Pursuant to sec- tion 29-277 of the Connecticut General Statutes,urea-form- tive details of fire-resistance-rated building elements.The ma- aldehyde foamed-in-place insulation shall not be installed terials of construction listed in Tables 720.1(1),720.1(2),and in any building or structure on or after June 1, 198E 720.1(3)shall be assumed to have the fire-resistance ratings !I� prescribed therein.Where materials that change the capacity 719.2 Concealed installation. Insulating materials, where for heat dissipation are incorporated into a fire-resistance-rated concealed as installed in buildings of any type of construction, assembly,fire test results or other substantiating data shall be I shall have a flame spread index of not more than 25 and a made available to the building official to show that the required smoke-developed index of not more than 450. fire-resistance-rating time period is not reduced. Exception:Cellulose loose-fill insulation that is not spray 720.1.1 Thickness of protective coverings.The thickness of applied,complying with the requirements of Section 719.6, fire-resistant materials required for protection of structural shall only be required to meet the smoke-developed index of members shall be not less than set forth in Table 720.1(1),ex- not more than 450. cept as modified in this section.The figures shown shall be 719.11 Facings.Where such materials are installed in con- the net thickness of the protecting materials and shall not in- cealed spaces in buildings of Type III,IV or V construction, clude any hollow space in back of the protection. the flame spread and smoke-developed limitations do not ap- 720.1.2 Unit masonry protection.Where required,metal ply to facings,coverings,and layers of reflective foil insula- ties shall be embedded in transverse joints of unit masonry tion that are installed behind and in substantial contact with the unexposed surface of the ceiling,wall or floor finish. for protection of steel columns.Such ties shall be as set forth in Table 720.1(1)or be equivalent thereto. 719.3 Ex I posed installation. Insulating materials, where ex- 720.13 Reinforcement for cast-in-place concrete col- i posed as installed in buildings of any type of construction,shall umn protection.Cast-in-place concrete protection for steel have a flame spread index of not more than 25 and asmoke-de- columns shall be reinforced at the edges of such members veloped index of not more than 450. with wire ties of not less than 0.18 inch(4.6 mm)in diameter Exception:Cellulose loose-fill insulation that is not spray wound spirally around the columns on a pitch of not more applied complying with the requirements of Section 719.6 than 8 inches(203 mm)or by equivalent reinforcement. shall only be required to meet the smoke-developed index of 720.1.4 Plaster application.The finish coatis not required y not more than 450. for plaster protective coatings where they comply with the 719.3.1 Attic floors.Exposed insulation materials installed design mix and thickness requirements of Tables 720.1(1), on attic floors shall have a critical radiant flux of not less 720.1(2)and 720.1(3). 2003 INTERNATIONAL BUILDING CODE°PORTION OF THE 2005 STATE BUILDING CODE 115 CHAPTERS INTERIOR FINISHES SECTION 801.0 GENERAL a noncombustible base or substrate that conforms to the 801.1 Scope:Interior finish and trim of buildings shall conform requirements of Section 2310.0. to the requirements of this section.Interior finish shall mean the 803.1.2 Type 4 construction:Exposed portions of structural ' exposed interior surfaces of buildings including,but not limited members complying with the requirements for buildings of to,fixed or movable walls and partitions,columns,ceilings,floor Type 4 construction in Sections 605.0 and 2304.0 shall not be finishes and wainscotting,paneling or other finish applied struc- subject to interior finish regulations. turally or for acoustical treatment, insulation, fireresistance,decoration or similar purposes. 803.13 Window exception:Show windows in the first story of buildings are permitted to be constructed of any approved 801.2 Installation and classification: All materials which are materials. required to restrict the spread of flame or to be flameresistant under the provisions of this code—including,but not limited to, 803.2 Classification:All materials used for interior finish and interior finish materials, fireretardant-treated wood, tents and trim shall be classified in accordance with ASTM E84 listed in tarpaulins,and interior hangings and decorations—shall meet Chapter 35. The classifications of interior finishes referred to the requirements for installation and classification as determined herein correspond to flame spread ratings determined by ASTM by the applicable test procedures listed in this section. E84 listed in Chapter 35 as follows:Class I flame spread,0-25; Class II flame spread,26-75;and Class III flame spread,76- SECTION 802.0 DEFINITIONS 200.Classification in accordance with ASTM E84 shall not be 802.1 General: The following words and terms shall, for the required for textile wall covering materials that comply with Section 803.6(2). purposes of this chapter and as used elsewhere in this code,have the meanings shown herein. 8033 Materials: Materials shall only be installed as interior finish and trim as specifically provided for in this code for the Flame spread:The propagation of flame over a surface. occupancy of the space in which the material is installed.Instal- Flame spread rating:The measurement of flame spread on the lation of any material for floor finish,interior finish and trim in surface of materials or their assemblies as determined by the a building of Type i or 2 construction within the scope permitted tests specified in this code(see Section 803.0). in this section or in Section 806.0 shall not declassify the building Flameresistance:That property of materials or combinations of with respect to the type of construction classification. component materials which restricts the spread of flame as 8033.1 Foam plastics: Foam plastics shall not be installed determined by the flameresistance tests specified in this code as interior trim or finish except in compliance with this section (see Section 807.2). and Section 2603.0. Floor finish:The finish placed on top of the floor,slab or other 8033.2 Smoke development:Interior wall and ceiling finish structural floor element. materials that have a smoke-developed rating greater than 450 when tested in accordance with ASTM E84 listed in Chapter SECTION 803.0 INTERIOR FINISH AND TRIM 35 shall not be permitted.A smoke-developed rating shall not 803.1 Exposed construction:These requirements shall not be be required for textile wall coverings complying with Section considered as requiring the installation of interior finish, but 803.6(2). where construction or fire protection materials are exposed in the 803.4 Required flame spread rating: Interior finish of walls use groups specified in Section 803.4, the hazard from rate of and ceilings shall have a flame spread rating not greater than that flame spread of such exposed materials shall not be greater than designated by the class prescribed for the various use groups that of the interior finish permitted for such occupancy. listed in Table 803.4, when tested in accordance with Section 803.1.1 Paper finish:The use of a surface finish of paper or 803.2. of material that does not have a greater fire hazard than paper 803A.1 Basements: In occupancies other than Use Group shall not be prohibited, provided that such finish does not R-3, Class I or II interior finish shall be required in all exceed 1/2s inch(1 mm)in thickness and is applied directly to basements or other underground spaces from which there is 85 THE BOCA NATIONAL BUILDING CODE/1996 no direct exit to the outside of the building, if subject to percent of the aggregate wall and ceiling areas of any room or occupancy for any purpose other than storage or service space,shall be of Class I,II or III materials. facilities. 803.6 Carpet and carpet-like wall coverings: Textile wall 803.4.2 Maximum flame spread: Interior finish materials coverings having a napped,tufted,looped,woven,nonwoven or with flame spread classifications greater than 200 shall not be similar surface,shall comply with the following: installed in any room or space subject to human occupancy, 1. Such materials shall have a Class I flame spread classifi- except to such extent as specifically approved on the basis of cation and be installed only in rooms or areas protected by a finding that such installation does not significantly increase an automatic sprinkler system installed in accordance with the life hazard. Chapter 9;or 803.4.3 Rooms and enclosed spaces: Requirements for 2. Such materials shall be tested in accordance with an 8-foot by 12-foot by 8-foot high(2438 mm by 3658 mm by 2438 rooms or enclosed spaces are based upon spaces enclosed in mm) room/corner fire test procedure utilizing aproduct- partitions of the building or structure, and where afire- mounting system, including adhesive, representative of resistance rating is required for the structural elements, the actual installation. Prior to testing, the sample shall be enclosing partitions shall extend from the floor to the ceiling. conditioned at 70 degrees F. (21 degrees C.)t 5 percent Partitions that do not comply with this shall be considered as enclosing spaces and the rooms or spaces on both sides and at a relative humidity of 50 percent t 5 percent until thereof shall be counted as one.In determining the applicable the sample reaches a rate of weight change of less than 0.1 requirements for rooms or enclosed spaces,the specific occu- percent per day. The product shall be exposed to a flame pancy thereof shall be the governing factor,regardless of the from a gas diffusion burner for 15 minutes.The fire expo- use group classification of the building or structure.Where an sure shall be 40 kW for the first 5 minutes,followed by an automatic sprinkler system installed in accordance with Sec- exposure of 150 kW for an additional 10 minutes. Such tion 906.2.1 or 906.2.2 is installed throughout a building, tests shall demonstrate that a product will not spread fire Class H or III interior finish shall be permitted where Class I to the edge of the specimen or cause flashover in the test or II materials,respectively,are required in Table 803.4. room' Table 803.4 803.7 Design load:Interior wall finish materials shall be capable INTERIOR FINISH REQUIREMENTS4 of resisting the horizontal load specified in Section 1606.9. Required Corridors SECTION 804.0 APPLICATION OF INTERIOR FINISH Use Group vertical providing Rooms or p exits and exit enclosed 804,1 Attachment: Where interior finish is regulated by the passageways® access' spacee requirements of this chapter, interior finish materials shall be A-1,A-2,A-3 I l° ll° applied or otherwise fastened in such a manner that such mate- A-4,8,E,f,I-1,R-1;R-2 I 11 Aff rials will not readily become detached when subjected to room 1- I -2 In Ir 0 temperatures of 200 degrees F.(93 degrees C.)for not less than 1-3 1 1 111 30 minutes. M: walls t 11 III " Ceilings i 11: lid ,; 804.2 Fireresistive and noncombustible construction:Interior R-3 III III III finish materials installed on walls, ceilings or structural ele- S,U 11 11 111 ments,which are required to provide a fireresistance rating or to Note a.For requirements applicable to rooms and enclosed spaces,see Section be of noncombustible construction,shall comply with the provi- 803.4.3. sions of Section 804.2.1 or 804.2.2. Note b.Class 111 interior finish materials are permitted in places of assembly with a capacity of 300 persons or less. 804.2.1 Application to structural elements: Interior finish Note c.Class III interior finish materials ark permitted for wainscotting or paneling materials applied to walls,ceilings or structural elements shall for not more than 1,000 square feet(93 m )of applied surface area in the grade be applied directly against the exposed surface of such struc- lobby where applied directly to a noncombustible base or over furring strips applied tural elements or to furring attached to such surfaces. In to a noncombustible base and fireblocked as required by Section 804.0. g Note d.Class III interior fiTsh materials are permitted in mercantile occupancies concrete or masonry construction, furring of wood or any of 3,000 square feet(279 in )or less gross area occupied for sales purposes on other material of similar combustible characteristics is per- the street floor only(balcony permitted). mitted.All concealed spaces created by furring shall be fire- I Note e.Lobby areas shall not be less than Class II. blocked at not more than 10-foot(3048 mm)intervals in any Note f.Where building height is over two stories,Class II shall be required. Note y.For the classifications of interior finishes referred to herein,see Section direction(see Section 721.6.6). 803.2.For interior finish requirements for exposed insulation,see Section 723.2. Note h.Walls and ceilings shall be a minimum of Class II materials in individual 804.2.2 Set-out construction:Where the interior finish is set rooms of not more than four persons in capacity.Where a building is equipped out or dropped distances greater than 13/4 inches (44 mm) throughout with an automatic sprinkler system installed in accordance with Section from the surface of such elements,only material of which both 906.2.1,the minimum requirement for interior finish shall be Class ll, qualify Note i.In Use Groups A,1-2 and 1-3,Class II interior wall finish material shall be faces q y as Class I shall be installed. permitted as wainscotting extending not more than 48 inches(1219 mm)above Exceptions the floor in corridors providing exit access. p 1. In buildings equipped throughout with an automatic 803.5 Interior trim: Baseboards, chair rails, moldings, trim sprinkler system installed in accordance with Sec- around openings and other interior trim, not in excess of 10 tion 906.2.1 or 906.2.2,Class II finish materials shall 86 t-ax;mutytistlrt UCt SU 2UUb 12:29 F.Ul 4=C3M F6 30 CORPORATION product Information PRODUCT STRUCTURE DIMENSIONS COMPONENT DESCRIPTION ENGLISH METRIC Finish Side Substrate Aluminum Foil 0.0003 inch 7.6 moon Adhesive Flame Retardant Hi h Performance Machlna Direction Reinforcing Fiber lass 2 finch 12 mm spacing Cross Direction Reinforcino Fiberglass 3 finch 8 mm s acln Back Side Substrate Natural Kraft 30 Ib./3000 eq ft 49 g1sq.rn EHX§IC&. PROPERT IES TEST METHOD MEASUREMf3NT/RE$ULT ENGLaSH ' METRIC Permeance ASTM E96 procedure A 0.02 perms 1.16 n ; .m%s Pa Puncture Resistance TAPPI T603 25 Beach units 0.75 Joules Machine Direction Tensile atrenam ASTM D828 Modlfled 40 Winch 7.1 kg/cm Cross Direction Tensile Strength ASTM D828 Modified 30 IbAnch 5.4 kg/cm Burst Strength ASTM D774 40 psi 2.8 kgkq cm Mold and Mildew Resistance ASTM C1338 no growth of organisms Humidity Resistance ASTM C1248 no corrosion or delamination Dimensional Stability ASTM D1204 0 150°F 65•9 does not exceed 0.25% change Low Tem emture Resistance ASTM C1263 Modified -41 de .F -41 de .0 High Temperature Resistance ASTM C1283 Modified +240 degY +115 deg.0 Emissivity ASTM,C1371 0.03 Thickness,Nominal Micrometer at Thickest Points 6.5 mils 165 rrterons Weight Per Area Scale/Balanco 201bA000 s .ft. 98 91sq.rn GIBE_RESISTANCE PROPERTIES TEST METH OD MEASUREMENT/R ESULT Flame Spread' UL 723/ASTM E84 10 foil side 30 paper Smoke Develo W UL 723/ASTM E84 0 foil side 5 eaper Metal Buildim ComWeita SBC' AS M E84 213 flAnia>s roM/50 smoke de%eto edom This product meets or exceeds the requirements of ASTM C1136, type ll,IV Properties and parameters are typical,subject to change without notice,and not intended as product specifications. Weights and thicknesses are nominal,With±10%tolerance. `Indicates Underwriter's Laboratories classified products."With classified adhesive and application rate.U.L.File No.R4481. Sheet No.;PIS-110 Revision NO.:3 Data:7129103 WARRANTY:ALL COMPAC products am produced undo eoatreead g6*fty etandude and are worranlcd to be from from dmfraet;n mat#AAI and workmarahp.Any rnow L, ,hewn to our satiafmcdon to be defective wkhln 30 dayx of daivery wM be replaced whhout charge. COMPAC CORPORATION will not be reapernskis for claim bcMd rcplaccrricntvf the matMal sokL Al pmduasara sold with the express underatandlrip Ihattire purdmwryA k10cmdariV dowmina tee suttablI4 of the malarlaitc r the purpose forwhlohtheysre Purchased.Recommendations byCOMPAC CORPORATION Mira netbeeeon:tmedaswarrandeeofany kind,Noubaman,raprcwnteM, r agent of COMPAC CORPORATION;S authonaed to gNo anygutuantee,wsrmntyrto make any representation in addition to,oraontraryto,the foregoing. COMPAC CORPORATIONm P.O.Box go. Old Flanders Road• Netcong,New Jersey 07357 I 973/347-3900m Us&Canada 3091631-9347 or o00/631-9350 Fax No.Y731347.4634 THE BOCA NATIONAL BUILDING CODE/1996 A will limit the average temperature rise of the unexposed surface 2603.4.1.6 Doors not required to have a fireresistance Lshall ot more t an e r 12I de rees s rating:Where doors are permitted without a fireresistance ire exposure �_itnwith the standard time-tem rature rating and foam plastic is used as a core material,the door ve o ASTM E11in Chapter ermal barrier facing shall be of metal having a minimum thickness of be installed such that said thermal barrier will stay in place 0.032-inch aluminum or 0.016-inch steel. a minimum of 15 minutes under the same test conditions. 2603.4.1.7 Exterior doors in buildings of Use Group 603.4.1 Thermal barrier not required:The thermal barrier R-3: In occupancies classified in Use Group R-3,/ foam- specified in Section 2603.4 is not required under the condi- filled exterior entrance doors that do not require a fire- tions set forth in any one of Sections 2603.4.1.1 through resistance rating shall be faced with wood or other 2603.4.1.10. approved materials. 2603.4.1.8 Garage doors:In other than occupancies clas- 2603.4.1.1 Siding backer board:Foam plastic to be used sified in Use Groups R-3 and U,where garage doors are as siding backer board,or where applied as insulation with not required to have a fireresistance rating and foam plastic re-siding over existing exterior wall construction, shall is utilized as a core material,the door facing shall be metal �— have a maximum thickness of 1/2 inch(13 mm)and shall having a minimum thickness of 0.032-inch(0.8 mm)alu- be separated from the interior of the building by not less minum or 0.010-inch (0.25 mm) steel or the facing shall than 2 inches(51 mm)of mineral fiber insulation or other be a minimum of 1/8-inch thick(3 mm)wood. approved materials. 2603.4.1.9 Residential garage doors:Where foam plastic 2603.4.1.2 Walk-in coolers: Where foam plastic is used is utilized in exterior garage doors classified as Use Group in a maximum thickness of 4 inches(102 mm)in walk-in R-3 and U,a thermal barrier is not required. coolers or in freezer units less than 400 square feet(37.2 2603.4.1.10 Exterior walls,one-story buildings:Ather- m-) in floor area, the foam plastic shall be covered by a mal barrier is not required in the exterior wall application metal facing of not less than 0.032-inch-thick (0.8 mm) provided for in Section 2603.6.8. aluminum or corrosion-resistant steel having a minimum base metal thickness of 0.016 inch(0.4 mm). 2603.5 Exterior applications: Foam plastic installed in or on the exterior side of walls of buildings shall also comply with the 2603.4.1.3 Masonry or concrete construction: Where applicable requirements of Section 1406.0. i the foam plastic is protected by a I-inch(25 mm)minimum thickness of masonry or concrete,a thermal barrier is not 2603.5.1 Protection:Foam plastics applied to the exterior of Zu e foundation walls shall be protected in accordance wth Section 1405.3.l 1. 4.1.4 At 'cs and crawl spaces: Within an attic or 2603.6 Exterior walls: Foam plastic installed in or on the space ere entry is made only for service of utili- exterior side of exterior walls in buildings of Type 1,2,3 or 4 plastic shall be protected against ignition by construction shall comply with the requirements of Sections k 11h-inch-thick(38 mm)mineral fiber insulation, /a-inc - p y q thick(6 mm woods el article boar 2603.6.1 through 2603.6.7 or,in one-story buildings,shall com- ply with the requirements of Section 2603.6.8. ar , /g-inch sum wallboard corrosion-resistant steel a ase metal thickness of 0 016 inch(0 4 m or 2603.6.1 Fireresistance rating: Foam plastic is permitted pproved rial installed'n su annerthat the within exterior walls provided that the wall assembly affords is not expgagd,The protective cove—rin-g-s-fiM the required fireresistance rating. e consistent With a requirements for the type of con- 2603.6.2 Thickness: The foam plastic shall be limited to a struction. maximum thickness of 4 inches(102 mm). 2603.4.1.5 Roofing:Foam plastic used in a roof covering 2603.6.3 Flame spread:The foam plastic core,coatings and assembly that employs a wood roof deck without the facings, when tested individually, shall each have a flame thermal barrier shall have the foam plastic separated from spread rating of 25 or less when tested in accordance with the interior of the building by wood structural panel ASTM E84 listed in Chapter 35. sheathing or tongue-and-groove wood plank sheathing not less than 1 5/;2 inch(12 mm)in thickness or other approved 2603.6.4 Fastening:Facing,coating and core materials shall materials. All wood structural panel roof sheathing shall be fastened to each other,and the overall assembly shall be fastened to the building frame to prohibit failure in bond due be bonded with exterior glue with edges supported by blocking,tongue-and-groovejointsorotherapproved type of temperatures that occur in a building fire, wind loads or her conditions. of edge support. other The requirements of Sections 2603.3 and 2603.4 are not 2603.6.5 Full-scale tests: Results of full-scale fire tests, applicable to foam plastic roof insulation used in roof deck which reflect an end-use configuration and which demon- construction that complies as an assembly with FM 4450 strate that the assembly in its final form does not show any- or UL 1256 listed in Chapter 35. tendency to propagate flame over the surface or through the For all roof applications, the smoke-developed rating core when exposed on the exterior face to a fire source,shall shall not be applicable. be submitted to the code official. Such testing shall be per- 280 THE BOCA NATIONAL BUILDING CODE/1996 will limit the average temperature rise of the unexposed surface 2603.4.1.6 Doors not required to have a fireresistance to not more than 250 degrees F.(121 degrees C.)after 15 minutes rating:Where doors are permitted without a fireresistanc of fire exposure,complying with the standard time-temperature rating and foam plastic is used as a core material,the door curve of ASTM E119 listed in Chapter 35.The thermal barrier facing shall be of metal having a minimum thickness of shall be installed such that said thermal barrier will stay in place 0.032-inch aluminum or 0.016-inch steel. for a minimum of 15 minutes under the same test conditions. 2603.4.1.7 Exterior doors in buildings of Use Group 2603.4.1 Thermal barrier not required:The thermal barrier R-3: In occupancies classified in Use Group R-3, foam- specified in Section 2603A is not required under the condi- filled exterior entrance doors that do not require a fire- tions set forth in any one of Sections 2603.4.1.1 through resis!ance rating shall be faced with wood or other 2603.4.1.10. approved materials. 2603.4.1.8 Garage doors:In other than occupancies clas- 2603.4.1.1 Siding backer board:Foam plastic to be used sified in Use Groups R-3 and U,where garage doors are as siding backer board,or where applied as insulation with not required to have a fireresistance rating and foam plastic re-siding over existing exterior wall construction, shall is utilized as a core material,the door facing shall be metal �— have a maximum thickness of 1/2 inch(13 mm)and shall having a minimum thickness of 0.032-inch(0.8 mm)alu- be separated from the interior of the building by not less minum or 0.010-inch (0.25 mm)steel or the facing shall than 2 inches(51 mm)of mineral fiber insulation or other be a minimum of 1/8-inch thick(3 mm)wood. 4..,.J,. approved materials. 2603.4.1.9 Residential garage doors:Where foam plastic 2603.4.1.2 Walk-in coolers: Where foam plastic is used is utilized in exterior garage doors classified as Use Group in a maximum thickness of 4 inches(102 mm)in walk-in R-3 and U,a thermal barrier is not required. coolers or in freezer units less than 400 square feet(37.2 2603.4.1.10 Exterior walls,one-story buildings:A ther- m-) in floor area, the foam plastic shall be covered by a mal barrier is not required in the exterior wall application metal facing of not less than 0.032-inch-thick (0.8 mm) provided for in Section 2603.6.8. t aluminum or corrosion-resistant steel having a minimum Ibase metal thickness of 0.016 inch(0.4 mm). 2603.5 Exterior applications: Foam plastic installed in or on h the exterior side of walls of buildings shall also comply with the 2603.4.1.3 Masonry or concrete construction: Where applicable requirements of Section 1406.0. the foam plastic is protected by a 1-inch(25 mm)minimum thickness of masonry or concrete,a thermal barrier is not 2603.5.1 Protection:Foam plastics applied to the exterior o required. foundation walls shall be protected in accordance wth Section 1405.3.11. 2603.4.1.4 Attics and crawl spaces: Within an attic or 2603.6 Exterior walls: Foam plastic installed in or on the crawl space where entry is made only for service of utili- exterior side of exterior walls in buildings of Type 1,2,3 or 4 ties, foam plastic shall be protected against ignition by construction shall comply with the requirements of Sections 1 1/2-inch-thick(38 mm)mineral fiber insulation, 1/4-inch- 2603.6.1 through 2603.6.7 or,in one-story buildings,shall com- thick(6 mm)wood structural panel,particleboard or hard- ply with the requirements of Section 2603.6.8. board,-r/$-inch gypsum wallboard,corrosion-resistant steel having a base metal thickness of 0.016 inch(0.4 mm),or 2603.6.1 Fireresistance rating: Foam plastic is permitted other approved material installed in such a manner that the within exterior walls provided that the wall assembly affords foam plastic is not exposed.The protective covering shall the required fireresistance rating. be consistent with the requirements for the type of con- 2603.6.2 Thickness: The foam plastic shall be limited to a struction. maximum thickness of 4 inches(102 mm). 2603.4.1.5 Roofing:Foam plastic used in a roof covering 2603.6.3 Flame spread:The foam plastic core,coatings and assembly that employs a wood roof deck without the facings, when tested individually, shall each have a flame thermal barrier shall have the foam plastic separated from spread rating of 25 or less when tested in accordance with the interior of the building by wood structural panel ASTM E84 listed in Chapter 35. sheathing or tongue-and-groove wood plank sheathing not 2603.6.4 Fastening:Facing,coating and core materials shall less than 1 5/62 inch(12 mm)in thickness or other approved be fastened to each other,and the overall assembly shall be materials. All wood structural panel roof sheathing shall fastened to the building frame to prohibit failure in bond due be bonded with exterior glue with edges supported by to temperatures that occur in a building fire, wind loads or blocking,tongue-and-groove joints or other approved type other conditions. of edge support. The requirements of Sections 2603.3 and 2603.4 are not 2603.6.5 Full-scale tests: Results of full-scale fire tests, applicable to foam plastic roof insulation used in roof deck which reflect an end-use configuration and which demon- construction that complies as an assembly with FM 4450 strate that the assembly in its final form does not show any or UL 1256 listed in Chapter 35. tendency to propagate flame over the surface or through the. For all roof applications, the smoke-developed rating core when exposed on the exterior face to a fire source,shall shall not be applicable. be submitted to the code official. Such testing shall be per- . 280 rax;dt)ucji?3zi fL UCt W 2UUb 11:ly V.U1 4=C)M "11111AL —. F6 30 CORPORATION product Information PRODUCT STRUCTURE DIMENSIONS COMPONENT DESCRIPTION ENGLISH METRIC Finish Side Substrate Aluminum Foil 0.0003 inch 7.6 mbron Adh031VC Flame Retardant Hi h Performance Marhfne Direction Reinforcing Fibe lass 2 finch 12 mm s arin Cross Direction Reinforcing Fiberglass 3 finch 8 mm spacing Back Side Substrate Natural Kraft 30 Ib./3000 eq ft 49 q1sq.m PHYSIC- PROPERTIES TEST METHOD MEASUREMItU E ULT ENGLISH ' METRIC Permeance ASTM E98 procedure A 0.02 perms 1.16 n /s .m%)Pa Puncture Resistance TAPPI TB03 25 Beach units 0,75 Joules Machine Direction Tensile Zitrengtll ASTM D828 Modified 40 lb./inch 7.1 kg/cm Cross Direction Tensile Strenj4h ASTM D828 Modified 30 IbJinch 5.4 kg/cm Burst Strength ASTM D774 40 psi 2.8 kghq cm Mold and Mildew Resistance ASTM C1338 no gmwth of organisms Humidily Resistance ASTM C1248 no corrosion or delamination Dimensional Stability ASTM D1204 IM 150°F 654C does not exceed 0.25% change Low Temperature Resistance ASTM C1263 Modified -41 de ,F .41 de .0 High Temperature Resistance ASTM C1283 Modified 4240 deq.F +115 deg.0 EmissIvIty ASTM.C1371 0.03 Thickness,Nominal Mlcmmeter at Thickest Poinis 6.5 mils 155 nicrons Wei htPerArea Scale/Balance 20IbA000s .ft. 98 /sq.m FIRE_ RESISTANCE PR OPERTIES TEST METH OD MEASUREMENT/R ESULT Flame 5 read• UL 723/ASTM E84 10 foil side 30 Damr Smoke Developed* UL 723/ASTM E84 0 foil side 5 Raper Matal Buildim Com ite Sac— ASTM E84 26 flame►n rO0150 amoke dewlo ed" This product meets or exceeds the requirements of ASTM C1136r type if,IV Properties and parameters are typical,subject to change Without notice,and not intended as product specifications. Weights and thicknesses are nominal,with±10%tolerance. `Indicates Underwriter's Laboratories classified products."With classified adhesive and application rate.U.L.File No.R4481. Sheet No.;P1S-110 Revision NO.:3 Data:7R9/03 WARRANTY:ALL COMPAC products are produeod undor eentrelad qualky atanduds and Ara worranicd to be froa flan detect in mst#"and workmamh1p.Any makrf Ll shown to our"parathion to be defecUm wlthm 30 days of derv"wAl be replaced without charge. COMPAC CORPORATION V11 not be reaponskie br da;m bcyond reptacemontof Ne material suit AN pmuduru are sold with the ewess undertWding that Ne purchaserwrA WeWdsndy detetrtline N6 suitat7k of the MOM r lhe purpose larwhlchtMYarepurftsed.Recommend:lensbyCOMPAC CORPORATION are netiabocon*ucdaswarrangeeofsnylund.Nosal"man.,epresonts ve,n agento(COMPACCORPORATIONkauthoftedbgooanyguarentes,werrenttrio make anyreprese talon inaddMon to,orcontrwyto,Nebregoing. COMPAC CORPORArIONe P.O.Box 98+ Old Flanders Road• Netcoeg,New Jersey 07857 , 973/347-3900e US d Caaada 800/631-9347 or 800/631-9356 Far No,973/J47.4634 THE BOCA NATIONAL BUILDING CODE/1996 no direct exit to the outside of the building, if subject to percent of the aggregate wall and ceiling areas of any room or occupancy for any purpose other than storage or service space,shall be of Class I,II or III materials. facilities. 803.6 Carpet and carpet-like wall coverings: Textile wall 803.4.2 Maximum flame spread: Interior finish materials coverings having a napped,tufted,looped,woven,nonwoven or with flame spread classifications greater than 200 shall not be similar surface,shall comply with the following: installed in any room or space subject to human occupancy, 1. Such materials shall have a Class I flame spread classifi- except to such extent as specifically approved on the basis of cation and be installed only in rooms or areas protected by a finding that such installation does not significantly increase an automatic sprinkler system installed in accordance with the life hazard. Chapter 9;or 803.4.3 Rooms and enclosed spaces: Requirements for 2. Such materials shall be tested in accordance with an 8-foot by 12-foot by 8-foot high(2438 mm by 3658 mm by 2438 rooms or enclosed spaces are based upon spaces enclosed in mm)room/corner fire test procedure utilizing aproduct- partitions of the building or structure, and where afire- mounting system, including adhesive, representative of resistance rating is required for the structural elements, the / actual installation. Prior to testing, the sample shall be enclosing partitions shall extend from the floor to the ceiling. conditioned at 70 degrees F. (21 degrees C.)t 5 percent Partitions that do not comply with this shall be considered as enclosing spaces and the rooms or spaces on both sides and at a relative humidity of 50 percent t 5 percent until thereof shall be counted as one.In determining the applicable the sample reaches a rate of weight change of less than 0.1 requirements for rooms or enclosed spaces,the specific occu- Percent per day.The product shall be exposed to a flame pancy thereof shall be the governing factor,regardless of the from a gas diffusion burner for 15 minutes.The fine expo- use group classification of the building or structure.Where an sure shall be 40 kW for the first 5 minutes,followed by an automatic sprinkler system installed in accordance with Sec- exposure of 150 kW for an additional 10 minutes. Such tion 906.2.1 or 906.2.2 is installed throughout a building, tests shall demonstrate that a product will not spread fire Class H or III interior finish shall be permitted where Class I to the edge of the specimen or cause flashover in the test or II materials,respectively,are required in Table 803.4. room. Table 803.4 803.7 Design load:Interior wall finish materials shall be capable INTERIOR FINISH REQUIREMENTS9 of resisting the horizontal load specified in Section 1606.9. Required Corridors SECTION 804.0 APPLICATION OF INTERIOR FINISH Use Group vertical providing Rooms or exits and exit i enclosed 804.1 Attachment: Where interior finish is regulated by the passageways access spaces requirements of this chapter, interior finish materials shall be A-1,A-2,A-3 I is II° applied or otherwise fastened in such a manner that such mate- A=4;H;E;F,I4,R-1,R=2';°':7*" "'":;="I "`;"11 °""" 111 rials will not readily become detached when subjected to room 1-2 craw `e ;u " :1lb Jiile` m temperatures of 200 degrees F.(93 degrees C.)for not less than 1-3 1 I III 30 minutes. M:=wails ::::`=:":'. ..M: . ...i;:.e.:.; �. •11 W ,µ�. ,�.11t" :.ceilings.-._ II°. 804.2 Fireresistive and noncombustible construction:Interior R-3 )II 111 III finish materials installed on walls, ceilings or structural ele- S,U II 11 111 ments,which are required to provide a fireresistance rating or to Note a.For requirements applicable to rooms and enclosed spaces,see Section be of noncombustible construction,shall comply with the provi- 803.4.3. lions of Section 804.2.1 or 804.2.2. Note b.Class III interior finish materials are permitted in places of assembly with a capacity of 300 persons or less. 804.2.1 Application to structural elements:Interior finish Note c.Class ill interiorfinish materials arg�permitted forwainscotting or paneling materials applied to walls,ceilings or structural elements shall for not more than 1,000 square feet(93 m)of applied surface area in the grade be applied directly against the exposed surface of such struc- lobby where applied directly to a noncombustible base or over furring strips applied elements or to to a noncombustible base and fireblocked as required by Section 804.0. furring attached to such surfaces. In Note d.Class III interior finjsh materials are permitted in mercantile occupancies concrete or masonry construction, furring of wood or any of 3,000 square feet(279 m)or less gross area occupied for sales purposes on other material of similar combustible characteristics is per- the street floor only(balcony permitted). mitted.All concealed spaces created by furring shall be fire- I Note e.Lobby areas shalt not be tees than Class II. blocked at not more than 10-foot 3048 mm intervals in an Note f.Where building height is over two stories,Class II shall be required. ( ) Y Note g.For the classifications of interior finishes referred to herein,see Section direction(see Section 721.6.6). 803.2.For interior finish requirements for exposed insulation,see Section 723.2. Note h.Walls and ceilings shall be a minimum of Class II materials in individual 804.2.2 Set-out construction:Where the interior finish is set rooms of not more than four persons in capacity.Where a building is equipped out or dropped distances greater than 13/4 inches (44 mm) throughout with an automatic sprinklersystem installed in accordance with Section from the surface of such elements,only material of which both 906.2.1,the minimum requirement for interior finish shall be Class 11. fY as Class I shall be installed.qualify Note 1.In Use Groups A,1-2 and 1-3,Class 11 interior wall finish material shall be faces q permitted as wainscotting extending not more than 48 inches(1219 mm)above Exceptions the floor in corridors providing exit access. 1. In buildings equipped Sthroughout with an automatic 8035 Interior trim: Baseboards, chair rails, moldings, trim sprinkler system installed in accordance with Sec- around openings and other interior trim, not in excess of 10 tion 906.2.1 or 906.2.2,Class II finish materials shall 86 November 8,2006 Thomas P.Daley,P.E. Project Manager 150 Wood Road Braintree,MA 02184-2509 Re:Town of South Windsor Public Works Facility Addition 137 Burgess Road Thank you for your response to our Corrections Notice of October 16,2006. This letter will address those issues relevant to the permit application on record from W.J. Mountford. As regards; .#4. l nfi no 0 Conn ti b) a a g ana is the ustible elements where the existing and new buil connects at the roo e. #7.As we discussed in an earlier phone conversation it will be necessary for you to apply for a State of CI'modification to allow the present scupper configuration as emergency overflow roof drains. #9.This item should be related to a building permit application,which to my knowledge has not been submitted.When that application is made a series of considerations will kick in, ie:roofing components,loads,drift surcharge,condition of existing supporting structure, etc. Please call with any questions concerning this matter. Sincerely yours, Christopher J.Dougan Chief Building Official cc.Mike Gantick,Vldimar Tussman,Jon Jackopsik,Wes Gutowski �40WN SFI`� o c �(1 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 SOR-CO TELEPHONE (860) 644-2511 December 12,2006 'Thomas P.Daley,P.E. Gannett Fleming,Inc. 150 Wood Road Braintree,MA 02184-2509 Re:Final Inspection Checklist Permit# 32487 Public Works Garage 137 Burgess Road The following list represents issues to be resolved so the above referenced permit maybe closed with a Certificate of Occupancy. 1) Improper wiring to receptacle outlet room.L= Z,4c4oPs1 e., 2) Seal/caulk around urinal 3) Missing coat hook for handicap toilet 4) Install four-way bracing at sprinkler riser 5) Provide tempered water for handicap lavatories 6) Clarify final resolution of sprinkler piping pop/up roof expansion joint 7) Seal ductwork penetrations to garage 8) Submit final engineer approved balance report WAQ 9) Garage CO monitor system verification test 10) Submit Final Inspection Report 11) State Modification:Roof Drainage,scuppers and overflows 12) Electrician to comply with engineer approved drawing re:supplementary electrical ground to water pipe Christopher J.Do Chief Building cc. Michael Gantick,S.Windsor Public Worms Jon Jackopsic, WJ Mountford Mike Rose,S.Windsor Building Dept.