Loading...
HomeMy WebLinkAbout2019-9-9 - 242 Dart Hill Road - Septic ApplicationK prr� n�,`s• Town of South Windsor — Health Department t C�-tea 4 = + 4 - n 1540 Sullivan Ave., South Windsor, CT 06074 — Mailing Address 1530 Sullivan Ave., South Windsor, CT 06074 — Office Address 45IIsr,q l�Y` Phone Number: (860) 337-6173, Fax Number: (860) 644-1930 APPLICATION FOR APPROVAL TO CONSTRUCT A SUBSURFACE SEWAGE DISPOSAL SYSTEM Application/Permit #: } To the Director of Health, Town of: 6KrW- W1"dFS0*-- Date: �] [ Application is hereby made for an approval to construct aLLsubsurface sewage disposal system for a: ko l4 &Nr) A--s. 9K I L�Q /aLL (Residential Building, Restaurant, Retail Building, etc.) located at: 2`'(� � 'i' !'r , �� �10 J I-A-rw (Street Address, Lot Number, Subdivision Name, Map, Block, Lot, etc.) New System _ Addition Repair Other Owner-4ft6,4L�4%46s� Address A,�Tel.No. ;u _ Installer _Address (L Tel.No. % U SA LSD Installer License No. 06Q3 a g In accordance with detailed'nrormation stated below: -0 Application fee paid r104 Signed Owner or duly authorized representative) ------------ — -- — --- - ---------------------- - -- - ------- - ­0 ------------------------- GENERAL INFORMATION Soil Tests Conducted (Date): Area of Special Concern (Y/N): If yes, Reason(s): Lot size Basis of Design (# of Bedrooms, Restaurant Seats, Building Size, etc.): Engineered Plan Required (Y/N): If yes, Name of Engineer: Address of Engineer: Design Plan Approved (Y/N): Type of Water Supply Well Driller's Name: Date of Approved Plan Revision Date: If well, has location been approved (Y/N): Address: OFFICE USE ONLY Approval to Construct issued by: _ Date: (Director of Health or Registered Sanitarian) Signature: FEE PAID: CHECK # DATE PAID: Title: sq.ft. Rev.7/16/18 Town of South Windsor -- Health Department a 1530 Sullivan Avenue, South Windsor, CT 06074 Phone Number: (860) 337-6173, Fax Number: (860) 644-1930 SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Application/Permit #: Property Owner: David Givens & Barbara Furnish Location: 242 Dart Hill Rd. DEEP TEST PIT DATA/SOIL DESCRIPTIONS DATE8/9/19 (Record all Test Pits) TEST PIT: 1 TEST PIT: 2 TEST PIT: TEST PIT: 0-8" Top soil 0-12" Top soil 9-24" Roots/Brown Sand 13-34" Light brown sand 25-29" Light brown sand TO bottom — Brown sand TO bottom — Light red sand with pebbles with pebbles 72" Deep 72" Dee Mottles: N/A Mottles: N/A Mottles: Mottles: GW: N/A GW: N/A GW: GW: Ledge: N/A Ledge: N/A Ledge: Ledge: Roots: 24" Roots: 44" Roots: Roots: Restrictive: N/A Restrictive: N/A Restrictive: Restrictive: COMMENTS: Area between trenches seems suitable GROUNDWATER TABLE (Near max., below max., etc.):. SOIL MOISTURE (High, medium, low, etc.): PERCOLATION TEST DATA DATE:8/9/19 (Record all Perc Tests) PERC:1 PERC: PERC: PERC: DEPTH: 36 INCHES DEPTH: DEPTH: DEPTH: PRESOAK:9:20am PRESOAK: PRESOAK: PRESOAK: TIME READING TIME READING TIME READING TIME READING 9:45am 24" 9:46am 26" 9:48am 27.5" 9:49am 29" 9"50am 29.5" 9:52am 30.5" 9:53am 30.5" 9:54am 31" 9:56am 32" PERC PERC PERC PERC RATE 10 min/unch RATE: RATE: RATE: COMMENTS: SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM LOCATION DRAWING INCLUDING ALL TEST PITS AND PERCOLATION HOLES wul SPECIAL CONDITIONS CONCLUSIONS Design Flow > 2000 GPD Suitable for Sewage Disposal X Public Water Supply Watershed Unsuitable for Sewage Disposal Probable High Groundwater Additional Investigation Req'd Slope > 25 percent Wet Season Monitoring Req'd Pere Rate < I min/inch Retest During Wet Season Pere Rate > 30 min/inch Licensed Engineer Plan Req'd Ledge < 5 feet below grade Other: Limited Suitable Area Open Watercourse or Wetlands Flood Plain / Seasonal Flooding Max. G.W. < 36 inches below grade DESIGN RECOMMENDATIONS/COMMENTS Well exception will be required test pit 60' from well head Form completed by: —Heather Oatis (Certified Local Health Agent or P.E.) Accuracy assured by (If P.E. completed form): (Certified Local Health Agent) Others present for site investigation (Engineer, developer, installer etc.): Melissa Pierce SW H jeff Poihenius Ski 's Wastewater Services homeowners Health Department Town of South Windsor — 1530 Sullivan Avenue, South Windsor, CT 06074 Phone Number: (860) 337-6173, Fax Number: (860) 644-1930 SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Application/Pcrmit #: Property Owner: David Givens & Barbara Furnish Location: 242 Dart Hill Rd. DEEP TEST PIT DATA/SOIL DESCRIPTIONS DATE8/9/19 (Record all Test Pits) TEST PIT: 1 TEST PIT: 2 TEST PIT: TEST PIT: 0-8" Top soil 0-12" Top soil 9-24" Roots/Brown Sand 13-34" Light brown sand 25-29" Light brown sand TO bottom — Brown sand TO bottom — Light red sand with pebbles with pebbles 72" Deep 72" Dee Mottles: N/A Mottles: N/A Mottles: Mottles: GW: N/A GW: N/A GW: GW: Ledge: N/A Ledge: N/A Ledge: Ledge: Roots: 24" Roots: 44" Roots: Roots: Restrictive: N/A Restrictive: N/A I Restrictive: I Restrictive: COMMENTS: Area between trenches seems suitable GROUNDWATER TABLE (Near max., below max., etc.): SOIL MOISTURE (High, medium, low, etc.); PERCOLATION TEST DATA DATE:8/9/ 19 (Record all Perc Tests) PERC: l PERC: PERC: PERC: DEPTH: 36 INCHES DEPTH: DEPTH: DEPTH: PRESOAK:9:20am PRESOAK PRESOAK: PRESOAK: TIME READING TIME READING TIME READING TIME READING 9:45am 24" 9:46am 26" 9:48am 27.5" 9:49am 29" 9" 50am 29.5" 9:52am 30.5" 9:53am 30.5" 9:54am 31 " 9:56am 32" PERC PERC PERC PERC RATE: < 10 min/unch RATE: RATE: RATE: COMMENTS: SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM LOCATION DRAWING INCLUDING ALL TEST PITS AND PERCOLATION H LES �rovj-IA- lc . x y r SPECIAL CONDITIONS CONCLUSIONS Design Flow > 2000 GPD Suitable for Sewage Disposal X Public Water Supply Watershed Unsuitable for Sewage Disposal Probable High Groundwater Additional Investigation Req'd Slope > 25 percent Wet Season Monitoring Req'd Perc Rate < 1 min/inch Retest During Wet Season Perc Rate > 30 min/inch Licensed Engineer Plan Req'd Ledge < 5 feet below grade Other: Limited Suitable Area Open Watercourse or Wetlands Flood Plain / Seasonal Flooding Max. G.W. < 36 inches below grade DESIGN RECOMMENDATIONS/COMMENTS Well exception will be required. test pit 60' from well hand Form completed by: Heather Oatis (Certified Local Health Agent or P.E.) Accuracy assured by (If P.E. completed form): (Certified Local Health Agent) Others present for site investigation (Engineer, developer, installer etc.): Melissa Pierce, SW HD. Jeff Polhemus. Skid's Wastewater Services. homeowners 9/9/2019`` Print Lookup Details State of Connecticut Lookup Detail View Name Name JONATHAN PIELA i License Information lookup License Expiration Granted License Licensure Actions or Pending License Type Number Date Date License Name Status Charges + Sub -Surface Sewage 6308 0913012011 03106/2018 JONATHAN ACTIVE CURRENT None Installer I I PIELA Generated on: 9/9/2019 9:14:06 AM https://www.elicense.ct.gov/Lookup/PrintLicenseDetails.aspx?cred=1469357&contact=592437 1 /1 State of Connecticut, Department of Public Health Well Separation Distance Exception Ap ication To: Environmental Engineering Program Date: .. 1 Department of Public Health 410 Capitol Ave., MS# 51SEW Local Health Department: �oylgl LJOP-0s jet_— P.O. Box 340308 Hartford, CT 06134-0308 Attn: &CG1n of IA- $ A Subject Property Address:�Z Replacement of. Septic Tank* Leaching System** Both Exception for: Septic Tank SC1 Leaching System Both Mailing Address: I KD rj�u.►✓rhu A✓iE�, Phone Number: S'Q 0 3 $ `1 — W } 3 Email Address: Town: JNvt,r f( L.J/ n..!-SJ►2__ Wells affected: —Owner's well Neighbors' well Both Basis of Design: # of Bedrooms: or Design Flow: Affected Properties Lot Number or Address Property Owner's Name Well Type Distance from well to: New Tank New System Subject Property Front Adjacent Rear Adjacent Left Adjacent Right Adjacent Shallow well pump(s) with suction pipe(s)? YES / NO If yes, show on plan & note distance if <75 feet. Building sewer or distribution piping <25 feet to well? YES t�_o )If yes, show on plan & note distance. Potability testing of affected wells? YES 40 If yes, are results satisfactory? YES / NO Is the replacement tank or leaching system located closer to well than the existing system? YES NO Does the subject property have any compliance issues concerning PHC Section 19-13-13100a? YES &If yes, explain. *Leaching system has been evaluated to confirm it is functioniizg satisfactorily? YES /0 ]f no, explain. 6epj(r �4"c,6i0 **Septic tank has been evaluated to confirm it is in satisfactory condition and properly baffled? ES NO If no, explain. Comments: Plan prepared by: Professional Engineer yLicensed Installer Other: Plan reviewed by: W44/% (Print Name and Title) Documentation Submitted: Soil Test Data Detailed Plan A�" Signature Please note, in accordance with CT General Statutes Section 19a-209c, the a licam is required to notify owners of properties with water supply wells a[Tecte y thi excepti equest. 1' piicabie, operty owner must sign below. Applicant's Signature: (Subject Property Owner) Date of Certified Mail Notification 12/2011 J oM 1 Itv5 TM PftOF^PTY N S ` x Ik ` 1� 1 �-' 4.c.JT A. J A M E S 1! I G G I N 'S 0� s,/61�'N TO. p/col�B�H�`►�2 PAW ��:.i)An SOiiTI'. :YI OR SCALE: 1"-30' , P a �- •t7'0�4� U . v le 3 ic. my FC 7, ci.:' r:rl. 1963 REMM "r:::ti;.:.a.RY ?, 1963 lit1� ` O �k`ic7x � / 7 � � icier/% � i• ��• _�__ �� v� ++ /�fJ v N-�•i�Gs- Q O!■ /I, I ___�•! � l..'�/11 lI DAL p// /,.AlF,� /3 e E sd f' 1 jnd 0 NOTE: .D A f' T L i CORNtfui AS AGREED M BY KU? MI C'S BROS., FFB, 6,' 1963; N m%=l I r. f q NG9f3o01ty DIVED .p 092019 O A SOUTH R i HEALTH DEPARTMENT 1 horaby c...':=;■ to the-.!L=tCoz• z'zl GARAuE SIDE YAnu NON -CO °Nti a,�.►^e & R- ~aces Ens.. BUILT PRIOR TO ZONING. , r.;!:ItJ Ii0IJ5E REAR YARD VAItiAI'CF'►�'�, . the i��.; �: p. :.: 'c' z •�:.: ;,-; ecc:.'. conditions GR„N r�,PER HIGGINS exhst.nq at t::. �► ... .: .:r�..lt correct, ana tha: raninc 6c: .: ro u_ ��oi ;tod. 1JORTGA t'F. SURVEY FOR THE. See note. CLC _ - ::. • j �r .'•Lt_ER .� r,o. ��� ` yl► `ti, z 4'c,nrf�,■I? iivr+� :Nt-=L LL u 4EYORS `'f HAPTI'nR7 FEDLRAL �• ^ Form # 3 4 -risok• NY'� y Local Health Department: Property Owner: l Technical Standards for Subsurface Sewage Disposal Systems 1/l/11 Final Inspection Report Application/Permit #: Property Address: Town: Licensed Installer: License M Approved Plan Information Check one: New System Repair/Replacement System Residential Building: bedrooms Large Tub: YES Aid Garbage Disposal: YES NQ Non residential Building/Residential Institution: GPD Plan Prepared by: Title: Plan Approved by: Date: Approval to Construct Date Permit Issued: Permit Issued Registered Sanitarian or Director of Health Inspection Information Type Date Licensed Installer Present? Yes/No Comments Field Stake Inspection (house, well, property lines, system etc.) Strip/Scarification Select Fill Placement Sieve required (Yes/No) Other: Final Inspection t Was 24 Hour (min) Installer Notice Given (Y/N) : I Date Final Inspection Requested: 'l 1 '� `-� Date of As -Built Final Inspection Completed by: A royal: Permit to Discharge Issued by: Date: Registered Sanitarian or Director of Health FORM #3 (Cont'd) Technical Standards for Subsurface Sewage Disposal Systems 1/l/11 Final Inspection Report House Sewer Information Pipe Type and ASTM Specification: Pipe Size: in,. Pipe Invert Elevations at: Foundation Wall: �11\ � Septic Tank: W . Z V Pipe Length: JA , ft. Pitch Required: (—, � 2 S �k Pitch Provided: Tank Information Septic Tank Size: 'n(y) Gallons Tank Inlet Elevation: , Tank Manufacturer: u S-�f ( i! n\ ,; Tank Outlet Elevation: Date Manufactured: Al Riser Needed (Y/N): E Outlet Filter Type/Manufacturer: ra b Size: Gallons Pump Alarm Checked Y Pump Chamber Manufacturer: Float Control Elevation Verified (ff[N): _ Grease Interceptor Grease Interceptor Tank Tank Size: Gallons Manufacturer: Leaching System Information Approved Aggregate: Free of silt dirt and debris (Y/N): Sieve Required (Y/N): \1 Filter Fabric Present (Y/N): Type: Aggregate Meets PHC Specifications (Y/N): Select Fill (Y/N):y Meets PHC Specifications (Y/N):�_ Sieve Information on File (Y/N): Leaching System Description raduct, size, length, number of rows, level or serial etc.): Effective Leaching Area Required: sq. ft. Reserve Area Provided (N/A, Y/N): /V \� Effective Leaching Area Provided: System Installed Per Approved Plan Elevations (Y/N): Elevation notes: sq. ft. Center to Center Spacing: Aj P ft. Elevations Field Verified (Y/N): ( Separation Distances Separation Distances Conform with Approved Plan (YIN): Separation Distances Field Verified (Y/N):