HomeMy WebLinkAbout1996-11-30 - 117 Dart Hill Road - Water Potability TestColumbia Environmental Laboratory
Drinking Water Analysis - Formaldehyde Testing
New England Property Services
117 New London TurnpikeCE STATE OF CONNECTICUT
DEPARTMENT OF HEALTH
Glastonbury, CT 06033 CERTIFICATION NUMBER
PH-0514
RE: Lab No. 9611147, Inv. No. 961554 November 30, 1996
SAMPLING LOCATION: 117 Daft Hill Road, South Windsor, Connecticut
SAMPLING / DELIVERY TIMES: Client Sampled 1000/1230 11/28/96
STANDARD WATER ANALYSIS STATE OF CONNECTICUT
TEST RESULTS RECOMMENDED / MAXIMUM LEVELS
PH UNITS
6.6
6.5 - 9.0 RECOMMENDED
RANGE
COLOR UNITS
<5
15 RECOMMENDED
MAXIMUM
ODOR 0-5
0 (none)
3 RECOMMENDED
MAXIMUM
TURBIDITY NTU
0.30
5 RECOMMENDED
MAXIMUM
ALKALINITY mg/L
--
NO RECOMMENDED LEVEL
CHLORIDE mg/L
29
250 MAXIMUM
ALLOWABLE
HARDNESS mg/L
170
0-60 soft, 61-120 mod. hard
121-180 hard, >181 v. hard
AMMONIA AS N mg/L
--
.050 RECOMMENDED
MAXIMUM
NITRITE AS N mg/L
.007
1.0 MAXIMUM
ALLOWABLE
NITRATE AS N mg/L
5.6
10.0 MAXIMUM
-_
ALLOWABLE
DETERGENTS mg/L
<0.5
0.5 MAXIMUM
ALLOWABLE
IRON mg/L
<0.10
0.3 RECOMMENDED
MAXIMUM
MANGANESE mg/L
.050 RECOMMENDED
MAXIMUM
SODIUM mg/L
--
28 RECOMMENDED
MAXIMUM
COLIFORM BACTERIA
0/100 ml
MAXIMUM
0/100 ml
ALLOWABLE
For the parameters analyzed, this is a satisfactory
potable drinking water supply.
If you have any questions, please feel free to call. ery truly yours
Jo C, Burrell
2 Lakeview Park West • Columbia, CT 06237 Telephone: (860) 228-0329