Loading...
HomeMy WebLinkAbout2024-1-29 - 1062 Pleasant Valley Road - Septic Soil Test. ,tit i'rrt Health Department Town of South Windsor — 1530 Sullivan Avenue, South Windsor, CT 06074 Phone Number: (860) 337-6173, Fax Number: (860) 644-1930 SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Application/Per nit #: 24-1 Property Owner: Robert Marouski Location: 1062 Pleasant Valley Rd DEEP TEST PIT DATA/SOIL DESCRIPTIONS DATE: 1/29/24 (Record all Test Pits) TEST PIT: 1 TEST PIT: 2 TEST PIT: TEST PIT: 0-12 Brown topsoil 0-12 topsoil, brown fine 12-24 Light brown tight sandy loam with roots. silty loam with small rocks, 12-24 light brown fine sandy 24-57 reddish brown fine loam, tight texture. sandy loam. 24-70 Reddish brown fine sandy loam. Looser texture. Mottles: None Mottles: None Mottles: Mottles: GW: 57 GW: 67 GW: GW: Ledge: None Ledge: None Led e: Ledge: Roots: 12 Roots: 12 Roots: Roots: Restrictive: 57 Restrictive: 67 Restrictive: Restrictive: COMMENTS: Pit 2 about 10 inches higher than pit 1; groundwater on level plane underground GROUNDWATER TABLE (Near max., below max., etc.):.40-50 inches below grade SOIL MOISTURE (High, medium, low, etc.): medium PERCOLATION TEST DATA DATE: 1 /29/24 (Record all Perc Tests) PERC:1 PERC: PERC: PERC: DEPTH:24 DEPTH: DEPTH: DEPTH: PRESOAK none PRESOAK: PRESOAK: PRESOAK: TIME READING TIME READING TIME READING TIME READING 12:28 1 5 12:30 3 12:34 475 12:39 6 12:44 7 12:49 8 12:54 8 5 12:59 925 1:04 9.75 1:09 10.5 PERC RATE. 7-8 PERC PERC PERC f RATE. RATE: RATE: COMMENTS: Perc rate less than 10 minutes per inch SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM LOCATION DRAWING INCLUDING ALL TEST PITS AND PERCOLATION HOLES SPECIAL CONDITIONS CONCLUSIONS Design Flow > 2000 GPD Suitable for Sewage Disposal Public Water Supply Watershed Unsuitable for Sewage Disposal Probable High Groundwater Additional Investigation Req'd Slope > 25 percent Wet Season Monitoring Req'd Perc Rate < 1 min/inch Retest During Wet Season Perc Rate > 30 min/inch Licensed Engineer Plan Req'd Ledge < 5 feet below grade Other: Limited Suitable Area Open Watercourse or Wetlands Flood Plain / Seasonal Flooding Max. G.W. < 36 inches below grade DESIGN RECOMMENDATIONS/COMMENTS Proposed system to be no less than 18 inches above ground water, 39 inches into grade (test pit 1). 577.5 square feet of effective leaching area required. MLSS: 22xl .75xl = 38.5 linear feet Form completed by.- Andrew Abbagnaro (Certified Local Health Agent or P.E.) Accuracy assured by (If P.E. completed form): (Certified Local Health Agent) Others present for site investigation (Engineer, developer, installer etc.): Justin Cyr