HomeMy WebLinkAboutCambria Architectural DrawingsREF.D W
UP
UP
2
A201
2
A200
1
A200
1
A201
A
A
B
B
C
C
D
D
E
E
H
H
J
J
55
4
3
2
1
3
A202
7
A503
1
G
G
6
F
F
2.5
POOL
MECH.
ROOM
042
POOL
EQPM
RM
041
040
INDOOR
SWIMMING POOL
152
STAIR A
102
KING 03
104
KING 01
037
CORRIDOR
039
FITNESS CENTER
038
STORAGE
036
GUEST LAUNDRY
035
ELEV. EQ. RM
008
WOMEN TLT
009
MEN TLT
034
DOS OFFICE
033
IT ROOM
029
WORK AREA
032
OFFICE031
OFFICE
002
CART001
VESTIBULE
004
WELCOME DESK
003
WELCOME LOBBY
ELEVATOR
LOBBY
007
010
COFFEE HOUSE
PUB
005
MARKET
006
HANGOUT
013
KITCHEN
011
PREFUNCTION
012
MEETING ROOM
015
FUNCTION STOR.
017
BREAK RM
018
LOCKERS
019
EMP. TLT
016
BOH CORRIDOR
020
BEV. STOR.ENG.
OFFICE
022
023
MECH. RM
028
ELEC.
153
STAIR B
LINEN
CHUTE
027
025
LAUNDRY
024
LAUNDRY OFFICE
026
LINEN STOR.
106
DQ 04
108
ADA KING 02
110
DQ 04
112
ADA KING 02
13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"6'-2"7'-0"13'-2"4'-0 1/2"9'-1 1/2"13'-2"1'-10 3/4"5'-3 1/4"9"15'-7 3/4"2'-6"6"
39'-11 1/2"58'-4 1/2"5 1/4"13'-2"13'-2"13'-2"26'-4"26'-4"13'-2"13'-2"3'-7 1/2"5'-7 3/4"13'-11 1/4"6'-6 1/4"5'-0"4'-5 1/4"6"1'-11"PAPBPCPD
P1
P2
11'-5"26'-3 7/8"79'-5 5/8"11'-11 3/4"13'-11 1/4"
1'-0 1/4"2'-0 1/2"
5'-11"19'-4 1/4"
7 3/4"
2'-8 3/4"
7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"
2'-8 3/4"2'-3 1/4"
7'-0"
2'-8 1/2"
11 1/2"12'-0"11 3/4"
1'-0 1/4"2'-0 1/2"
5'-11"
3 1/2"
5 1/2"13'-4 1/2"20'-4" R.O.5'-4"5 1/2"16'-5 1/4"19'-4" R.O.22'-7 1/4"7'-0"26'-4"10"3'-4"13'-3 7/8"14'-0"8'-5 5/8"2'-3 1/4"6'-4"1'-6"5'-8"1'-6"6'-4"2'-3 1/4"1'-10 1/2"6'-2 1/2"12'-1 3/4"3'-10"2'-8 3/4"2'-3 1/4"7'-0"7'-4"7'-0"2'-3 1/4"2'-8 7/8"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"2'-8 3/4"5 1/2"4'-11 7/8"5 1/2"20'-3 5/8"2'-0"A501
1
1
A300
1
A300
2
A300
2
A300
A.3
B.5
B.5
7.27.2
2.8
K.8L.8
7.57.5
8.5
9
8.88.8
L.6
L.6
16'-11 3/8"3'-4"8 7/8"5'-2 3/4"R.O.3'-4"48'-10 1/8"1'-9"11'-5"26'-9 1/2"25'-10 1/2"53'-1 5/8"17'-3 3/4"5"
3'-0"
5'-0"
GAS
FIREPLACE -
SEE MECH. DWG
8
M
M
L
L K.2
1
A202
W2R
W2L
1L1
1 HR
1
A400
2
A400
4
A400
A502
1
014
``
152
B
040
A
152
A
039
038
042
041
040
C
040
B
151
A
035
008
A
009
A
029
A
033
032031004
002
001
013
A
012
C
012
E
016
C
012
D
026
025
A
025
B
153
B
153
A
028023
A
023
B
019
015
A503
10
W2LW2LW2L
W2R.1
W2R.1
W2L.1
W15
W11
W10W8
W15
W6
W9
IW2
IW3
IW4
W2RW2RW2RW2RW2LW2R
W2L.1
1A1
1 HR
A500
1162'-8 1/4"016
B
017
020
022
3'-4"3'-10"34'-8 3/4"11"3'-4"19'-0 1/8"1'-4 3/8"
42'-10 3/4"22'-3 1/8"
66'-6 1/4"26'-4"39'-11 1/2"25'-10 1/2"037
016
A
013
B
A600
1
A600
6
1
A401
1
A402
3
A400
008
B
008
C
008
D
008
E
009
B
5'-11"5'-10"25'-11"2'-0 3/4"011
010
043
MEN'S
007A
ELEV.57'-4 7/8"21'-0 1/4"5'-0 3/8"043
1
A301
1
A301
2
A301
2
A301
7
5
8
1
2
6
2
6
43
8
8
9 9
7'-0"
036
B
036
A
H.8 H.2 D.7
2.6
GR6GR6
6"8.98.9
C.5
C.5
D.5
D.5
A.5
A.5
6'-5"18'-1 1/4"6'-5"6'-5"30'-1 1/4"A701
1
A704
1
A710
1
3.5
4.5
4.3
N
034
012
B
012
A
012
F
G9
G9
8.7
6.2
6.3
B.3
ROLL-IN
SHOWER
ROLL-IN
SHOWER
1
A403
5'-2"8'-0"5'-2"8'-0"
DASHED LINE INDICATES CONTINUOUS 10 MIL
VAPOR BARRIER DIRECTLY BEHIND INTERIOR
GYPSUM BOARD. CONTRACTOR TO EXTEND THE
VAPOR BARRIER UP TO CEILING. REFER TO FLOOR
PLANS AND SECTIONS FOR MORE INFORMATION.
2
A401
Sim
2
A403
Sim
024
A950
1
044
WOMEN'S044
6
6
151
B151
CORRIDOR
8888
KING STUDIO
ACCESSIBLE KING STUDIO
ROOM TYPE 1ST
FLOOR
2ND
FLOOR
3RD
FLOOR
4TH
FLOOR
ROOM
TOTALS
2
GUESTROOM MATRIX
2
12
17
12
14
12 38
45
TOTAL PER FLOOR
GRAND TOTAL
-1 2 3
108
DOUBLE QUEEN STUDIO
-
-
1
3 3 3
- -
9
1
2 1 2 1 6
ACCESSIBLE DOUBLE QUEEN
6 35 34 33
6
DOUBLE QUEEN SUITE
ONE-BEDROOM KING SUITE
ACCESSIBLE ONE-BEDROOM KING SUITE - - -1 1
12
- -1 1 2ONE-BEDROOM KING TOWER SUITE
SQUARE FOOTAGE
GRAND TOTAL 71,604 S.F.
18,312 17,764 17,764 17,764
INDICATES DOOR TYPE - REFER TO SHEET
A900 FOR DOOR SCHEDULE & DOOR/FRAME
MATERIALS & ELEVATIONS
TYPICAL SECTION AND DETAIL FLAGS:
REFERS TO SECTION OR ELEVATION NUMBER
REFERS TO DRAWING SHEET NUMBER
KEY NOTE
INDICATES WALL CONSTRUCTION TYPE & HEIGHT, REFER
TO SHEET G004 FOR DETAILED ASSEMBLY DESCRIPTIONS
INDICATES ROOM NAME AND NUMBER, REFER
TO ID SHEETS FOR ROOM FINISHES
ROOM
NAME
###
DATUM POINT, INDICATES ELEVATION OR SOIL
BORING LOCATION
INDICATES WINDOW TYPE, REFER TO SHEET
A800 FOR WINDOW ELEVATIONS1t
SYMBOL
LEGEND
#
3B
HEARING IMPAIRED SPEECH ROOM (19 TOTAL)
REFER TO ELECTRICAL DRAWINGS
101
A
ADA / ANSI COMPLIANT ACCESSIBLE ROOM,
REFER TO ENLARGED PLANS FOR DETAILS
4
0 8' 16' 20'
1/8" = 1'-0"
12'
REVISIONS
N PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443331ST FLOOR PLANA101CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 060741 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A101
1 1ST FLOOR PLAN
NOTE: SEE SHEETS A700-A713 FOR ENLARGED
GUESTROOM TYPE PLANS & ELEVATIONS.
GENERAL NOTES - FLOOR PLAN
1 ALL DIMENSIONS ARE TO FACE OF STUD WALL AND/OR MASONRY (UNLESS
NOTED OTHERWISE).
2 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONS
AND/OR CONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH
ACTUAL CONDITIONS, CONTACT THE ARCHITECT FOR CLARIFICATION
3 WALL THICKNESS INDICATED ON DRAWINGS SHALL BE CONSTANT FOR THE
ENTIRE LENGTH OF THE WALL (U.N.O.)
4 PROVIDE BEHIND WALL REINFORCING AND BLOCKING AS REQUIRED FOR DOOR
STOPS, ATTACHMENT OF MILLWORK, CASEWORK, TOILET ACCESSORIES, ETC.
5 ALL OUTSIDE CORNERS THROUGHOUT THE INTERIOR SPACE TO HAVE METAL
CORNER BEADS
6 REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION ON LOCATIONS
AND TYPES OF FINISH MATERIALS.
7 SAW-CUT OR TOOLED CONTROL JOINTS AT INTERIOR EXPOSED CONCRETE
FLOORS SHALL BE CAULKED WITH SEALANT AS REQ'D.
8 REFER TO ENLARGED GUEST ROOM PLANS FOR DOOR TAGS & TYPES
9 REFER TO CAMBRIA SUITES BY CHOICE STANDARDS MANUAL FOR ADDITIONAL
REQ'S FOR FIXTURES & EQUIPMENT, PASSENGER ELEVATORS, ELEVATOR
LOBBIES, CORRIDORS, STORAGE AREAS, MECHANICAL, ELECTRICAL, &
EQUIPMENT ROOMS
10 FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICES TO
BE LOCATED PER LOCAL CODE. FIRE EXTINGUISHER LOCATIONS WITHIN THE
PUBLIC SPACE SHALL BE CONTAINED WITHIN FULLY RECESSED CABINETS
11 FIRE ALARM SYSTEM SHALL HAVE PERMANENTLY INSTALLED AUDIBLE & VISUAL
ALARMS COMPLYING WITH NFPA 70, 72, & 101 & AS REQ'D BY LOCAL
AUTHORITIES. ALARMS MUST BE LOCATED IN PUBLIC & COMMON USE AREAS &
GUEST ROOMS DESIGNATED AS "GUEST ROOMS WITH COMMUNICATION
FEATURES" AT A MINIMUM. WHERE EMPLOYEE AREAS HAVE AUDIBLE ALARMS,
THE WIRING SHALL BE DESIGNED SO VISIBLE ALARMS CAN BE INTEGRATED
INTO THE SYSTEM, UNLESS GREATER STANDARDS ARE REQ'D BY LOCAL
AUTHORITIES. REFER TO ELECTRICAL AND FIRE PROTECTION DRAWINGS.
12 REFER TO FF&E PACKAGE WITHIN SPECIFICATIONS FOR FURNITURE, BUILT-IN
MILLWORK AND FINISH SPECIFICATIONS
13 WALL MOUNTED EQUIP., FIXTURES, ETC. LOCATED BETWEEN 27" AND 80" A.F.F.
SHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL PER ANSI ACCESSIBILITY
STANDARDS.
14 GUESTROOM WALL TYPES: AT ALL WALL TILE LOCATIONS, CONTRACTOR TO
PROVIDE 5/8" CEMENT BOARD IN LIEU OF GYPSUM BOARD. PRIOR TO
INSTALLING TILE, CONTRACTOR TO COVER WALL WITH RED GUARD, OR EQUAL.
AT ALL OTHER WET WALL LOCATIONS THAT DO NOT HAVE TILE, CONTRACTOR
TO USE MOISTURE RESISTANT GYPSUM BOARD (TYP).
15 ALL FIRST FLOOR BEARING WALLS, INCLUDING EXTERIOR WALLS, ARE TO HAVE
(2) 2x6 @ 16" O.C., TYPICAL.
FLAG NOTES - FIRST FLOOR PLAN
1 THIS ELEVATOR SHALL PROVIDE EMERGENCY ACCESS TO ALL FLOORS AND BE
LARGE ENOUGH TO ACCOMODATE AN AMBULANCE STRETCHER.
2 EGRESS STAIR IN CONCRETE MASONRY STAIR ENCLOSURE.
3 KEYCARD READER ENTRANCE HARDWARE MOUNTED SO THAT TOP OF READER
IS A MAXIMUM OF 48" ABOVE GRADE OR A.F.F.
4 ALL SECONDARY GUEST ENTRANCES MUST BE WELL LIT AND IDENTIFIABLE.
5 LINE OF ROOF / CANOPY ABOVE
6 STAND PIPE MUST NOT ENCROACH INTO REQUIRED STAIR EGRESS CLEAR
WIDTH.
7 DRYER VENT LOUVER - REFER TO ELEVATIONS.
8 HOTEL LAUNDRY EQUIPMENT - REFER TO ENLARGED PLAN
9 GUEST LAUNDRY EQUIPMENT - REFER TO ENLARGED PLAN
CONTRACTOR TO PROVIDE VERTICAL GYPSUM
BOARD CONTROL JOINTS A MAXIMUM OF 30'-0" O.C.
WHERE WALLS / PARTITIONS RUN UNINTERRUPTED
IN A STRAIGHT PLANE. FIELD LOCATE WITH
ARCHITECT PRIOR TO INSTALLING.
GENERAL CONTRACTOR SHALL INSTALL 7/16" PLYWOOD
BLOCKING A TOTAL OF 48" IN WIDTH (3 STUD CAVITIES) CENTERED
BEHIND THE TV SHOWN ON ANY INCLUDED PLANS OR INTERIOR
ELEVATIONS FROM 48" AFF TO 98" AFF. ELECTRICAL
CONTRACTOR SHALL PROVIDE OUTLET AND DATA CONNECTIONS
AS REQUIRED PER ELECTRICAL DRAWINGS. DO NOT INSTALL THE
ITEMS BEHIND THE TV UNTIL THE MOUNTING BRACKET IS
SUPPLIED BY THE GENERAL CONTRACTOR AND/OR OWNER.
TV BLOCKING NOTE:
NOTE:
COLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PER PLANS,
SECTIONS AND DETAILS. UNDER NO CIRCUMSTANCES ARE
THE BEAMS/COLUMNS TO BE LEFT EXPOSED UNLESS
APPROVED BY CHOICE AND OWNER.
STEEL FIRE PROOFING NOTE:
2
4
2 08/09/2016 ADD. #2
4 06/25/2018 BULLETIN #1
6 11/05/2018 BULLETIN #3
8 12/26/2018 BULLETIN #5
DN
UP
DN
UP
2
A201
2
A200
1
A200
1
A201
ABCDEHJ
55
4
3
2
1
3
A202
7
G
6
F
2.5
201
DQ 02
203
DQ 02
205
DQ 02
211
DQ 02
213
DQ 02
215
KING 01
202
KING 03
204
KING 01
206
DQ 04
212
DQ 04
214
DQ 04
216
DQ 04
218
KING 01
220
KING 01
222
KING 02
224
ADA DQ 01
251
CORRIDOR
252
STAIR A
219
LINEN
225
ELEC.
ELEVATOR
LOBBY
217
226
DQ 04
228
DQ 04
230
DQ 04
232
DQ 04
234
KING 01
236
KING 01
238
DQ 04
240
DQ 04
229
1 BR SUITE 03
231
DQ 02
233
DQ SUITE
235
DQ SUITE
237
DQ SUITE
239
KING 01
241
KING 01253
STAIR B
242
LINEN CHUTE
250
CORR.
POOL ROOF BELOW
ROOF
BELOW
207
DQ 02
209
KING 01
208
ADA KING 01210
DQ 04
PAPBPCPD
P1
P2
2'-8 3/4"
7'-0"7'-4"7'-0"
2'-3 1/4"2'-8 7/8"
7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"
2'-3 3/4"
26'-3 7/8"79'-5 5/8"25'-11"
1'-0 1/4"2'-0 1/2"
5'-11"19'-3 1/2"
1'-0"
2 3/4"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"6'-2"7'-0"13'-2"4'-0 1/2"9'-1 1/2"13'-2"7'-11"18'-7 3/4"3'-10 3/4"7'-0"5'-0"7'-0"45'-8"7'-0"7'-3 7/8"7'-0"1'-11 7/8"13'-2"13'-2"13'-2"26'-4"26'-4"13'-2"13'-2"3'-7 1/2"5'-7 3/4"13'-11 1/4"18'-4 1/2"3'-10 3/4"
7'-0"5'-0"7'-0"7'-4"7'-0"57'-8"7'-0"
1
A300
1
A300
2
A300
2
A300
B.5
7.27.2
7.57.5
9
8.88.8
8
M
M L
1
A202
1
A400
2
A400
4
A400
A650
2
W3
W1RW1LW1RW1LW1RW1LW1RW1LW1R
W1L
W1L
W1R
W1R
W1L
W3
W1L
W1R
W1L
W1R
W1L
W1R
W1L
W5
W5 3'-0"5'-4 7/8"31'-6"3'-0"8'-4 3/4"
42'-10 3/4"
105'-4"
TELE/
DATA
223
221
VENDING
A500
2
174'-1 3/4"26'-7 3/4"2'-5 1/8"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"2'-8 3/4"3'-9 1/2"7'-0"6'-6 1/4"8 1/2"19'-3 5/8"5'-10 7/8"17'-3 3/4"79'-1 7/8"26'-7 3/4"5 1/4"5 1/4"GR6
219
225
223
242
253
252
A600
2
A600
7
1
A401
1
A402
W1L
3
A400
RD
OD
SLOPE @ 1/4"
FT MIN. -TYP.
OD
RD
RD
OD 5 1/2"29'-11 1/2"5'-2 1/4"29'-10 1/8"217A
ELEV.
1
A301
1
A301
2
A301
2
A301
1
2
3
H.8 H.2 D.7
8.98.9
C.5D.5 A.5
A709
1
A704
1
A702
1
A711
1
A703
1
A707
1
3.5
4.5
4.3
N
A700
1 17'-6"1
A403
8"8"8888
8
8
8
8
8
8
8
8
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR 1L1
1 HR
1L1
1 HR
1L1
1 HR 1L1
1 HR
1L1
1 HR 1L1
1 HR
KING STUDIO
ACCESSIBLE KING STUDIO
ROOM TYPE 1ST
FLOOR
2ND
FLOOR
3RD
FLOOR
4TH
FLOOR
ROOM
TOTALS
2
GUESTROOM MATRIX
2
12
17
12
14
12 38
45
TOTAL PER FLOOR
GRAND TOTAL
-1 2 3
108
DOUBLE QUEEN STUDIO
-
-
1
3 3 3
- -
9
1
2 1 2 1 6
ACCESSIBLE DOUBLE QUEEN
6 35 34 33
6
DOUBLE QUEEN SUITE
ONE-BEDROOM KING SUITE
ACCESSIBLE ONE-BEDROOM KING SUITE - - -1 1
12
- -1 1 2ONE-BEDROOM KING TOWER SUITE
SQUARE FOOTAGE
GRAND TOTAL 71,604 S.F.
18,312 17,764 17,764 17,764
INDICATES DOOR TYPE - REFER TO SHEET
A900 FOR DOOR SCHEDULE & DOOR/FRAME
MATERIALS & ELEVATIONS
TYPICAL SECTION AND DETAIL FLAGS:
REFERS TO SECTION OR ELEVATION NUMBER
REFERS TO DRAWING SHEET NUMBER
KEY NOTE
INDICATES WALL CONSTRUCTION TYPE & HEIGHT, REFER
TO SHEET G004 FOR DETAILED ASSEMBLY DESCRIPTIONS
INDICATES ROOM NAME AND NUMBER, REFER
TO ID SHEETS FOR ROOM FINISHES
ROOM
NAME
###
DATUM POINT, INDICATES ELEVATION OR SOIL
BORING LOCATION
INDICATES WINDOW TYPE, REFER TO SHEET
A800 FOR WINDOW ELEVATIONS1t
SYMBOL
LEGEND
#
3B
HEARING IMPAIRED SPEECH ROOM (19 TOTAL)
REFER TO ELECTRICAL DRAWINGS
101
A
ADA / ANSI COMPLIANT ACCESSIBLE ROOM,
REFER TO ENLARGED PLANS FOR DETAILS
4
0 8' 16' 20'
1/8" = 1'-0"
12'
REVISIONS
N PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443332ND FLOOR PLANA102CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 060742 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A102
1 2ND FLOOR PLAN
NOTE: SEE SHEETS A700-A713 FOR ENLARGED
GUESTROOM TYPE PLANS & ELEVATIONS.
GENERAL NOTES - FLOOR PLAN
1 ALL DIMENSIONS ARE TO FACE OF STUD WALL AND/OR MASONRY (UNLESS
NOTED OTHERWISE).
2 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONS
AND/OR CONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH
ACTUAL CONDITIONS, CONTACT THE ARCHITECT FOR CLARIFICATION
3 WALL THICKNESS INDICATED ON DRAWINGS SHALL BE CONSTANT FOR THE
ENTIRE LENGTH OF THE WALL (U.N.O.)
4 PROVIDE BEHIND WALL REINFORCING AND BLOCKING AS REQUIRED FOR DOOR
STOPS, ATTACHMENT OF MILLWORK, CASEWORK, TOILET ACCESSORIES, ETC.
5 ALL OUTSIDE CORNERS THROUGHOUT THE INTERIOR SPACE TO HAVE METAL
CORNER BEADS
6 REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION ON LOCATIONS
AND TYPES OF FINISH MATERIALS.
7 SAW-CUT OR TOOLED CONTROL JOINTS AT INTERIOR EXPOSED CONCRETE
FLOORS SHALL BE CAULKED WITH SEALANT AS REQ'D.
8 REFER TO ENLARGED GUEST ROOM PLANS FOR DOOR TAGS & TYPES
9 REFER TO CAMBRIA SUITES BY CHOICE STANDARDS MANUAL FOR ADDITIONAL
REQ'S FOR FIXTURES & EQUIPMENT, PASSENGER ELEVATORS, ELEVATOR
LOBBIES, CORRIDORS, STORAGE AREAS, MECHANICAL, ELECTRICAL, &
EQUIPMENT ROOMS
10 FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICES TO
BE LOCATED PER LOCAL CODE. FIRE EXTINGUISHER LOCATIONS WITHIN THE
PUBLIC SPACE SHALL BE CONTAINED WITHIN FULLY RECESSED CABINETS
11 FIRE ALARM SYSTEM SHALL HAVE PERMANENTLY INSTALLED AUDIBLE & VISUAL
ALARMS COMPLYING WITH NFPA 70, 72, & 101 & AS REQ'D BY LOCAL
AUTHORITIES. ALARMS MUST BE LOCATED IN PUBLIC & COMMON USE AREAS &
GUEST ROOMS DESIGNATED AS "GUEST ROOMS WITH COMMUNICATION
FEATURES" AT A MINIMUM. WHERE EMPLOYEE AREAS HAVE AUDIBLE ALARMS,
THE WIRING SHALL BE DESIGNED SO VISIBLE ALARMS CAN BE INTEGRATED
INTO THE SYSTEM, UNLESS GREATER STANDARDS ARE REQ'D BY LOCAL
AUTHORITIES. REFER TO ELECTRICAL AND FIRE PROTECTION DRAWINGS.
12 REFER TO FF&E PACKAGE WITHIN SPECIFICATIONS FOR FURNITURE, BUILT-IN
MILLWORK AND FINISH SPECIFICATIONS
13 WALL MOUNTED EQUIP., FIXTURES, ETC. LOCATED BETWEEN 27" AND 80" A.F.F.
SHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL PER ANSI ACCESSIBILITY
STANDARDS.
14 GUESTROOM WALL TYPES: AT ALL WALL TILE LOCATIONS, CONTRACTOR TO
PROVIDE 5/8" CEMENT BOARD IN LIEU OF GYPSUM BOARD. PRIOR TO
INSTALLING TILE, CONTRACTOR TO COVER WALL WITH RED GUARD, OR EQUAL.
AT ALL OTHER WET WALL LOCATIONS THAT DO NOT HAVE TILE, CONTRACTOR
TO USE MOISTURE RESISTANT GYPSUM BOARD (TYP).
15 ALL FIRST FLOOR BEARING WALLS, INCLUDING EXTERIOR WALLS, ARE TO HAVE
(2) 2x6 @ 16" O.C., TYPICAL.
FLAG NOTES - TYPICAL FLOOR PLAN
1 VERTICAL MECHANICAL SHAFT CONNECTING THE FIRST FLOOR TO ROOF
STRUCTURE PLENUM. REFER TO MECHANICAL DRAWINGS FOR REQUIRED SIZES.
2 ICE MACHINE, REFER TO ELECTRICAL AND PLUMBING DRAWINGS.
3 LINEN CHUTE SHAFT, REFER TO DETAILS.
CONTRACTOR TO PROVIDE VERTICAL GYPSUM
BOARD CONTROL JOINTS A MAXIMUM OF 30'-0" O.C.
WHERE WALLS / PARTITIONS RUN UNINTERRUPTED
IN A STRAIGHT PLANE. FIELD LOCATE WITH
ARCHITECT PRIOR TO INSTALLING.
GENERAL CONTRACTOR SHALL INSTALL 7/16" FRTW PLYWOOD
BLOCKING A TOTAL OF 48" IN WIDTH (3 STUD CAVITIES)
CENTERED BEHIND THE TV SHOWN ON ANY INCLUDED PLANS
OR INTERIOR ELEVATIONS FROM 48" AFF TO 98" AFF.
ELECTRICAL CONTRACTOR SHALL PROVIDE OUTLET AND DATA
CONNECTIONS AS REQUIRED PER ELECTRICAL DRAWINGS. DO
NOT INSTALL THE ITEMS BEHIND THE TV UNTIL THE MOUNTING
BRACKET IS SUPPLIED BY THE GENERAL CONTRACTOR AND/OR
OWNER.
TV BLOCKING NOTE:
NOTE:
COLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PER
PLANS, SECTIONS AND DETAILS. UNDER NO
CIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFT
EXPOSED UNLESS APPROVED BY CHOICE AND OWNER.
STEEL FIRE PROOFING NOTE:
4
4
4
4 06/25/2018 BULLETIN #1
8 12/26/2018 BULLETIN #5
8 8 8 8 8 8
DN
UP
DN
UP
2
A201
2
A200
1
A201
A
A
B
B
C
C
D
D
E
E
HJ
55
4
3
2
1
3
A202
7
6
F
F
2.5
301
DQ 02
303
DQ 02
305
DQ 02
311
KING 01
313
DQ 02
315
KING 01
351
CORRIDOR
352
STAIR A
302
KING 03
304
KING 01
310
DQ 04
312
DQ 04
314
DQ 04
316
DQ 04
318
KING 01
320
KING 01
322
1 BR SUITE 02
326
1 BR SUITE 01
328
DQ 04
330
ADA KING 01
332
DQ 04
334
KING 01
336
KING 01
338
DQ 04
340
DQ 04
353
STAIR B
340
LINEN CHUTE
341
KING 01
339
KING 01
337
DQ SUITE
331
DQ 02
329
1 BR SUITE 03
319
LINEN
325
ELEC.
350
CORR.
ELEVATOR
LOBBY
317
307
DQ 02
309
KING 01
306
DQ 04
308
ADA KING 01
13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"
2'-8 3/4"
7'-0"7'-4"7'-0"
2'-3 1/4"2'-8 7/8"
7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"9'-8 3/4"
2'-3 1/4"
7'-0"7'-4"7'-0"
2'-3 3/4"
1'-9"
11'-5"26'-3 7/8"79'-5 5/8"25'-11"
1'-0 1/4"2'-0 1/2"
5'-11"19'-3 1/2"
8 1/2"3'-10 3/4"7'-0"5'-0"7'-0"3'-5 1/4"3'-10 3/4"7'-0"5'-0"7'-0"7'-4"7'-0"2'-8 7/8"2'-3 1/4"7'-0"7'-3 7/8"7'-0"2'-3 3/8"6'-6 1/4"7'-0"3'-9 1/2"2'-8 3/4"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"2'-5 1/8"26'-7 3/4"2'-0"1
A300
1
A300
2
A300
2
A300
B.5
B.5
7.27.2
L.8
7.57.5
9
8.88.8
L.6
8
M
M
L13'-2"26'-4"26'-4"26'-4"13'-2"13'-2"23'-2 1/2"18'-4 1/2"1
A400
2
A400
4
A400
A650
3
W5
W5
W1RW1LW1RW1LW1RW1LW1RW1LW1R
W3
W1L
W1L
W1R
W1R
W1L
W3
W1L
W1R
W1L
W1R
W1L
W1R
W1L
105'-0 1/2"
3'-10 3/4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"12'-0"7'-0"3'-1 3/4"
323
TELE/DATA
321
VEND'G 31'-6 1/8"3'-0"5'-4 3/4"21'-0 1/4"5'-0 3/8"173'-10 1/4"5 1/4"11'-5"27'-0"78'-9 1/2"17'-3 3/4"5'-10 7/8"19'-3 5/8"8 1/2"5 1/4"31'-6"3'-0"7'-4 3/4"
41'-10 3/4"23'-3 1/8"1'-4 3/8"
66'-6 1/4"
GR6
GR6
GR6
319
325
323
340
353
352
A600
3
A600
8
1
A401
W1L
3
A400
1
A301
1
A301
2
A301
2
A301
W1LW1R W1R
335
DQ SUITE
333
DQ SUITE
H.8
H.8
H.2
H.2
GR6
D.7
8.98.9
C.5
C.5
D.5
D.5
A.5
A.5
A701
1
A709
1
A704
1
A706
1
A705
1
A703
1
A707
1
A713
1
3.5
4.5
N
1
A403
7'-0"6'-2"
6"29'-11 1/2"5'-7 3/4"16'-9 1/2"
GR6
1L1
1 HR1L1
1 HR
1L1
1 HR1L1
1 HR1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
8888
8
88888
8 8
8
8
8
8
8
8
5 1/2"29'-6"5 1/2"5'-2 1/4"5 1/2"29'-5 1/4"5 1/2"KING STUDIO
ACCESSIBLE KING STUDIO
ROOM TYPE 1ST
FLOOR
2ND
FLOOR
3RD
FLOOR
4TH
FLOOR
ROOM
TOTALS
2
GUESTROOM MATRIX
2
12
17
12
14
12 38
45
TOTAL PER FLOOR
GRAND TOTAL
-1 2 3
108
DOUBLE QUEEN STUDIO
-
-
1
3 3 3
- -
9
1
2 1 2 1 6
ACCESSIBLE DOUBLE QUEEN
6 35 34 33
6
DOUBLE QUEEN SUITE
ONE-BEDROOM KING SUITE
ACCESSIBLE ONE-BEDROOM KING SUITE - - -1 1
12
- -1 1 2ONE-BEDROOM KING TOWER SUITE
SQUARE FOOTAGE
GRAND TOTAL 71,604 S.F.
18,312 17,764 17,764 17,764
INDICATES DOOR TYPE - REFER TO SHEET
A900 FOR DOOR SCHEDULE & DOOR/FRAME
MATERIALS & ELEVATIONS
TYPICAL SECTION AND DETAIL FLAGS:
REFERS TO SECTION OR ELEVATION NUMBER
REFERS TO DRAWING SHEET NUMBER
KEY NOTE
INDICATES WALL CONSTRUCTION TYPE & HEIGHT, REFER
TO SHEET G004 FOR DETAILED ASSEMBLY DESCRIPTIONS
INDICATES ROOM NAME AND NUMBER, REFER
TO ID SHEETS FOR ROOM FINISHES
ROOM
NAME
###
DATUM POINT, INDICATES ELEVATION OR SOIL
BORING LOCATION
INDICATES WINDOW TYPE, REFER TO SHEET
A800 FOR WINDOW ELEVATIONS1t
SYMBOL
LEGEND
#
3B
HEARING IMPAIRED SPEECH ROOM (19 TOTAL)
REFER TO ELECTRICAL DRAWINGS
101
A
ADA / ANSI COMPLIANT ACCESSIBLE ROOM,
REFER TO ENLARGED PLANS FOR DETAILS
4
0 8' 16' 20'
1/8" = 1'-0"
12'
REVISIONS
N PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443333RD FLOOR PLANA103CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 060743 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A103
1 3RD FLOOR PLAN
NOTE: SEE SHEETS A700-A713 FOR
ENLARGED GUESTROOM TYPE PLANS &
ELEVATIONS.
GENERAL NOTES - FLOOR PLAN
1 ALL DIMENSIONS ARE TO FACE OF STUD WALL AND/OR MASONRY (UNLESS
NOTED OTHERWISE).
2 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONS
AND/OR CONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH
ACTUAL CONDITIONS, CONTACT THE ARCHITECT FOR CLARIFICATION
3 WALL THICKNESS INDICATED ON DRAWINGS SHALL BE CONSTANT FOR THE
ENTIRE LENGTH OF THE WALL (U.N.O.)
4 PROVIDE BEHIND WALL REINFORCING AND BLOCKING AS REQUIRED FOR DOOR
STOPS, ATTACHMENT OF MILLWORK, CASEWORK, TOILET ACCESSORIES, ETC.
5 ALL OUTSIDE CORNERS THROUGHOUT THE INTERIOR SPACE TO HAVE METAL
CORNER BEADS
6 REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION ON LOCATIONS
AND TYPES OF FINISH MATERIALS.
7 SAW-CUT OR TOOLED CONTROL JOINTS AT INTERIOR EXPOSED CONCRETE
FLOORS SHALL BE CAULKED WITH SEALANT AS REQ'D.
8 REFER TO ENLARGED GUEST ROOM PLANS FOR DOOR TAGS & TYPES
9 REFER TO CAMBRIA SUITES BY CHOICE STANDARDS MANUAL FOR ADDITIONAL
REQ'S FOR FIXTURES & EQUIPMENT, PASSENGER ELEVATORS, ELEVATOR
LOBBIES, CORRIDORS, STORAGE AREAS, MECHANICAL, ELECTRICAL, &
EQUIPMENT ROOMS
10 FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICES TO
BE LOCATED PER LOCAL CODE. FIRE EXTINGUISHER LOCATIONS WITHIN THE
PUBLIC SPACE SHALL BE CONTAINED WITHIN FULLY RECESSED CABINETS
11 FIRE ALARM SYSTEM SHALL HAVE PERMANENTLY INSTALLED AUDIBLE & VISUAL
ALARMS COMPLYING WITH NFPA 70, 72, & 101 & AS REQ'D BY LOCAL
AUTHORITIES. ALARMS MUST BE LOCATED IN PUBLIC & COMMON USE AREAS &
GUEST ROOMS DESIGNATED AS "GUEST ROOMS WITH COMMUNICATION
FEATURES" AT A MINIMUM. WHERE EMPLOYEE AREAS HAVE AUDIBLE ALARMS,
THE WIRING SHALL BE DESIGNED SO VISIBLE ALARMS CAN BE INTEGRATED
INTO THE SYSTEM, UNLESS GREATER STANDARDS ARE REQ'D BY LOCAL
AUTHORITIES. REFER TO ELECTRICAL AND FIRE PROTECTION DRAWINGS.
12 REFER TO FF&E PACKAGE WITHIN SPECIFICATIONS FOR FURNITURE, BUILT-IN
MILLWORK AND FINISH SPECIFICATIONS
13 WALL MOUNTED EQUIP., FIXTURES, ETC. LOCATED BETWEEN 27" AND 80" A.F.F.
SHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL PER ANSI ACCESSIBILITY
STANDARDS.
14 GUESTROOM WALL TYPES: AT ALL WALL TILE LOCATIONS, CONTRACTOR TO
PROVIDE 5/8" CEMENT BOARD IN LIEU OF GYPSUM BOARD. PRIOR TO
INSTALLING TILE, CONTRACTOR TO COVER WALL WITH RED GUARD, OR EQUAL.
AT ALL OTHER WET WALL LOCATIONS THAT DO NOT HAVE TILE, CONTRACTOR
TO USE MOISTURE RESISTANT GYPSUM BOARD (TYP).
15 ALL FIRST FLOOR BEARING WALLS, INCLUDING EXTERIOR WALLS, ARE TO HAVE
(2) 2x6 @ 16" O.C., TYPICAL.
FLAG NOTES - TYPICAL FLOOR PLAN
1 VERTICAL MECHANICAL SHAFT CONNECTING THE FIRST FLOOR TO ROOF
STRUCTURE PLENUM. REFER TO MECHANICAL DRAWINGS FOR REQUIRED SIZES.
2 ICE MACHINE, REFER TO ELECTRICAL AND PLUMBING DRAWINGS.
3 LINEN CHUTE SHAFT, REFER TO DETAILS.
CONTRACTOR TO PROVIDE VERTICAL GYPSUM BOARD
CONTROL JOINTS A MAXIMUM OF 30'-0" O.C. WHERE
WALLS / PARTITIONS RUN UNINTERRUPTED IN A
STRAIGHT PLANE. FIELD LOCATE WITH ARCHITECT
PRIOR TO INSTALLING.
GENERAL CONTRACTOR SHALL INSTALL 7/16" FRTW
PLYWOOD BLOCKING A TOTAL OF 48" IN WIDTH (3 STUD
CAVITIES) CENTERED BEHIND THE TV SHOWN ON ANY
INCLUDED PLANS OR INTERIOR ELEVATIONS FROM 48" AFF
TO 98" AFF. ELECTRICAL CONTRACTOR SHALL PROVIDE
OUTLET AND DATA CONNECTIONS AS REQUIRED PER
ELECTRICAL DRAWINGS. DO NOT INSTALL THE ITEMS
BEHIND THE TV UNTIL THE MOUNTING BRACKET IS SUPPLIED
BY THE GENERAL CONTRACTOR AND/OR OWNER.
TV BLOCKING NOTE:
NOTE:
COLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PER
PLANS, SECTIONS AND DETAILS. UNDER NO
CIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFT
EXPOSED UNLESS APPROVED BY CHOICE AND OWNER.
STEEL FIRE PROOFING NOTE:
4
4
4
4 06/25/2018 BULLETIN #1
8 12/26/2018 BULLETIN #5
DN
DN
2
A201
2
A200
1
A200
1
A201
A
A
B
B
C
C
D
D
E
E
HJ
55
4
3
2
1
3
A202
7
6
F
2.5
409
KING 01
411
KING 01
413
DQ 02
415
KING 01
451
CORRIDOR
452
STAIR A
402
KING 03
404
KING 01
406
DQ 04
408
1 BR SUITE ADA
412
1 BR SUITE 04
414
DQ 04
416
DQ 04
418
KING 01420
KING 01
422
1 BR SUITE 02
ELEVATOR
LOBBY
417
425
ELEC.
419
LINEN
426
1 BR SUITE 01
428
DQ 04
430
ADA KING 01
432
DQ 04
434
KING 01
436
KING 01
438
DQ 04
440
DQ 04
453
STAIR B
442
LINEN CHUTE
429
1 BR SUITE 03
431
DQ 02
433
DQ SUITE
439
KING 01
441
KING 01
450
CORR.
401
DQ 02
403
DQ 02
405
DQ 02
407
DQ 02
1
A300
1
A300
2
A300
B.5
B.5
7.27.2
7.57.5
9
8.88.8
8
M
M
L
1
A400
2
A400
4
A400
A650
4
W5
W5
W1R W1L W1R W1L W1R W1L W1R W1L W1R
W3
W1L
W1L
W1R
W1R
W1L
W3
W1L
W1R
W1L
W1R
W1L
W1R
W1L
W1R
W1L
TELE/
DATA
423
421
VEND'G
419
425
423
442
453
452
A600
4
A600
9
1
A401
W1L
3
A400
5'-0" CLR.
EQEQ
5'-2 1/4"
1'-9"
11'-5"26'-4"79'-5 1/2"25'-11"
1'-0 1/4"2'-0 1/2"
5'-11"19'-3 1/2"
8 1/2"2'-10 3/4"1'-0"7'-0"5'-0"7'-0"3'-5 1/4"3'-10 3/4"7'-0"5'-0"7'-0"7'-4"7'-0"2'-8 7/8"2'-3 1/4"7'-0"7'-3 7/8"7'-0"1'-11 7/8"6'-6 1/4"7'-0"3'-9 1/2"7'-0"7'-4"7'-0"2'-5 1/8"2'-7"7'-0"7'-4"7'-0"2'-8 3/4"2'-0"6 1/4"13'-2"26'-4"26'-4"26'-4"13'-2"13'-2"23'-2 1/2"18'-4 1/2"105'-4"
3'-10 3/4"
7'-0"5'-0"7'-0"7'-4"7'-0"57'-8"7'-0"
3'-1 3/4"5 1/2"31'-0 5/8"3'-0"4'-11 1/4"5 1/2"21'-0 1/4"4'-6 7/8"5 1/2"173'-10 1/4"2'-0 1/2"11'-5"27'-0 1/2"78'-9"17'-3 3/4"5'-10 7/8"19'-3 5/8"8 1/2"5 1/4"31'-6"3'-0"7'-4 3/4"
41'-10 3/4"23'-3 1/8"1'-4 3/8"
66'-6 1/4"
6 1/4"
1
A301
1
A301
2
A301
2
A301
105'-4"
437
DQ SUITE
435
DQ SUITE
H.8
H.8
H.2
H.2 D.7
2.6
8.98.9
C.5
C.5
D.5
D.5
A.5
A.5
A701
1
A712
1
A708
1
A704
1
A706
1
A705
1
A703
1
A705
1
A704
1
3.5
4.5
N
1
A403
30'-5 1/2"5'-7 3/4"29'-11 1/2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"13'-2"
7'-0"6'-2"
2'-3 3/4"
7'-0"7'-4"7'-0"
2'-3 1/4"2'-8 3/4"
7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"5'-0"7'-0"7'-4"7'-0"
2'-8 3/4"2'-3 1/4"
7'-0"7'-4"7'-0"
2'-8 3/4"
GR6GR6
GR6
GR6
GR6
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
8
888888
888
1L1
1 HR
1L1
1 HR
8
8
8 8
8 8
8
8
KING STUDIO
ACCESSIBLE KING STUDIO
ROOM TYPE 1ST
FLOOR
2ND
FLOOR
3RD
FLOOR
4TH
FLOOR
ROOM
TOTALS
2
GUESTROOM MATRIX
2
12
17
12
14
12 38
45
TOTAL PER FLOOR
GRAND TOTAL
-1 2 3
108
DOUBLE QUEEN STUDIO
-
-
1
3 3 3
- -
9
1
2 1 2 1 6
ACCESSIBLE DOUBLE QUEEN
6 35 34 33
6
DOUBLE QUEEN SUITE
ONE-BEDROOM KING SUITE
ACCESSIBLE ONE-BEDROOM KING SUITE - - -1 1
12
- -1 1 2ONE-BEDROOM KING TOWER SUITE
SQUARE FOOTAGE
GRAND TOTAL 71,604 S.F.
18,312 17,764 17,764 17,764
INDICATES DOOR TYPE - REFER TO SHEET
A900 FOR DOOR SCHEDULE & DOOR/FRAME
MATERIALS & ELEVATIONS
TYPICAL SECTION AND DETAIL FLAGS:
REFERS TO SECTION OR ELEVATION NUMBER
REFERS TO DRAWING SHEET NUMBER
KEY NOTE
INDICATES WALL CONSTRUCTION TYPE & HEIGHT, REFER
TO SHEET G004 FOR DETAILED ASSEMBLY DESCRIPTIONS
INDICATES ROOM NAME AND NUMBER, REFER
TO ID SHEETS FOR ROOM FINISHES
ROOM
NAME
###
DATUM POINT, INDICATES ELEVATION OR SOIL
BORING LOCATION
INDICATES WINDOW TYPE, REFER TO SHEET
A800 FOR WINDOW ELEVATIONS1t
SYMBOL
LEGEND
#
3B
HEARING IMPAIRED SPEECH ROOM (19 TOTAL)
REFER TO ELECTRICAL DRAWINGS
101
A
ADA / ANSI COMPLIANT ACCESSIBLE ROOM,
REFER TO ENLARGED PLANS FOR DETAILS
4
0 8' 16' 20'
1/8" = 1'-0"
12'
REVISIONS
N PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443334TH FLOOR PLANA104CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 060744 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A104
1 4TH FLOOR PLAN
NOTE: SEE SHEETS A700-A713 FOR
ENLARGED GUESTROOM TYPE PLANS &
ELEVATIONS.
GENERAL NOTES - FLOOR PLAN
1 ALL DIMENSIONS ARE TO FACE OF STUD WALL AND/OR MASONRY (UNLESS
NOTED OTHERWISE).
2 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONS
AND/OR CONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH
ACTUAL CONDITIONS, CONTACT THE ARCHITECT FOR CLARIFICATION
3 WALL THICKNESS INDICATED ON DRAWINGS SHALL BE CONSTANT FOR THE
ENTIRE LENGTH OF THE WALL (U.N.O.)
4 PROVIDE BEHIND WALL REINFORCING AND BLOCKING AS REQUIRED FOR DOOR
STOPS, ATTACHMENT OF MILLWORK, CASEWORK, TOILET ACCESSORIES, ETC.
5 ALL OUTSIDE CORNERS THROUGHOUT THE INTERIOR SPACE TO HAVE METAL
CORNER BEADS
6 REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION ON LOCATIONS
AND TYPES OF FINISH MATERIALS.
7 SAW-CUT OR TOOLED CONTROL JOINTS AT INTERIOR EXPOSED CONCRETE
FLOORS SHALL BE CAULKED WITH SEALANT AS REQ'D.
8 REFER TO ENLARGED GUEST ROOM PLANS FOR DOOR TAGS & TYPES
9 REFER TO CAMBRIA SUITES BY CHOICE STANDARDS MANUAL FOR ADDITIONAL
REQ'S FOR FIXTURES & EQUIPMENT, PASSENGER ELEVATORS, ELEVATOR
LOBBIES, CORRIDORS, STORAGE AREAS, MECHANICAL, ELECTRICAL, &
EQUIPMENT ROOMS
10 FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICES TO
BE LOCATED PER LOCAL CODE. FIRE EXTINGUISHER LOCATIONS WITHIN THE
PUBLIC SPACE SHALL BE CONTAINED WITHIN FULLY RECESSED CABINETS
11 FIRE ALARM SYSTEM SHALL HAVE PERMANENTLY INSTALLED AUDIBLE & VISUAL
ALARMS COMPLYING WITH NFPA 70, 72, & 101 & AS REQ'D BY LOCAL
AUTHORITIES. ALARMS MUST BE LOCATED IN PUBLIC & COMMON USE AREAS &
GUEST ROOMS DESIGNATED AS "GUEST ROOMS WITH COMMUNICATION
FEATURES" AT A MINIMUM. WHERE EMPLOYEE AREAS HAVE AUDIBLE ALARMS,
THE WIRING SHALL BE DESIGNED SO VISIBLE ALARMS CAN BE INTEGRATED
INTO THE SYSTEM, UNLESS GREATER STANDARDS ARE REQ'D BY LOCAL
AUTHORITIES. REFER TO ELECTRICAL AND FIRE PROTECTION DRAWINGS.
12 REFER TO FF&E PACKAGE WITHIN SPECIFICATIONS FOR FURNITURE, BUILT-IN
MILLWORK AND FINISH SPECIFICATIONS
13 WALL MOUNTED EQUIP., FIXTURES, ETC. LOCATED BETWEEN 27" AND 80" A.F.F.
SHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL PER ANSI ACCESSIBILITY
STANDARDS.
14 GUESTROOM WALL TYPES: AT ALL WALL TILE LOCATIONS, CONTRACTOR TO
PROVIDE 5/8" CEMENT BOARD IN LIEU OF GYPSUM BOARD. PRIOR TO
INSTALLING TILE, CONTRACTOR TO COVER WALL WITH RED GUARD, OR EQUAL.
AT ALL OTHER WET WALL LOCATIONS THAT DO NOT HAVE TILE, CONTRACTOR
TO USE MOISTURE RESISTANT GYPSUM BOARD (TYP).
15 ALL FIRST FLOOR BEARING WALLS, INCLUDING EXTERIOR WALLS, ARE TO HAVE
(2) 2x6 @ 16" O.C., TYPICAL.
FLAG NOTES - TYPICAL FLOOR PLAN
1 VERTICAL MECHANICAL SHAFT CONNECTING THE FIRST FLOOR TO ROOF
STRUCTURE PLENUM. REFER TO MECHANICAL DRAWINGS FOR REQUIRED SIZES.
2 ICE MACHINE, REFER TO ELECTRICAL AND PLUMBING DRAWINGS.
3 LINEN CHUTE SHAFT, REFER TO DETAILS.
BID ALTERNATE #1 - ROOF INSULATION:
CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT
ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL
THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE
ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT
INSULATION. (PER NFPA 13, A DRY SUPPRESSION
SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE
ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH
INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID
INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO
ROOF MANUFACTURER'S MINIMUM INSULATION/COVER
BOARD (IF NEEDED).
CONTRACTOR TO PROVIDE VERTICAL GYPSUM
BOARD CONTROL JOINTS A MAXIMUM OF 30'-0" O.C.
WHERE WALLS / PARTITIONS RUN UNINTERRUPTED IN
A STRAIGHT PLANE. FIELD LOCATE WITH ARCHITECT
PRIOR TO INSTALLING.
GENERAL CONTRACTOR SHALL INSTALL 7/16" FRTW PLYWOOD
BLOCKING A TOTAL OF 48" IN WIDTH (3 STUD CAVITIES)
CENTERED BEHIND THE TV SHOWN ON ANY INCLUDED PLANS
OR INTERIOR ELEVATIONS FROM 48" AFF TO 98" AFF.
ELECTRICAL CONTRACTOR SHALL PROVIDE OUTLET AND DATA
CONNECTIONS AS REQUIRED PER ELECTRICAL DRAWINGS. DO
NOT INSTALL THE ITEMS BEHIND THE TV UNTIL THE MOUNTING
BRACKET IS SUPPLIED BY THE GENERAL CONTRACTOR AND/OR
OWNER.
TV BLOCKING NOTE:
NOTE:
COLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PER
PLANS, SECTIONS AND DETAILS. UNDER NO
CIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFT
EXPOSED UNLESS APPROVED BY CHOICE AND OWNER.
STEEL FIRE PROOFING NOTE:
4
4
4
4 06/25/2018 BULLETIN #1
8 12/26/2018 BULLETIN #5
2A2011A2001A201AABBCCDDEEHJJ5543213A2027GG6FF2.51A3002A300B.5B.57.27.2L.87.57.598.8L.68MMLL1A4002A4004A400OVERFLOW SCUPPEROVERFLOW SCUPPEROVERFLOW SCUPPEROVERFLOW SCUPPEROVERFLOW SCUPPERSLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.ROOF SCUPPER W/ CONDUCTOR HEAD & DSOPENING6'-0"1A4013A4001A3011A3012A301RDRDRDRDRDSLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4"FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.151012141636151971111111111122222222222333333333333333333333333349999312141919815SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.339SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/4" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.SLOPE @ 1/2" FT MIN. -TYP.181818181818H.8H.8H.2H.2D.78.98.9C.5C.5D.5D.5A.5A.53.54.54.3NG91A403813202020ODODODODOD13131308'16'20'1/8" = 1'-0"12'REVISIONSNPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ROOF PLANA105CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 060745 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A1051ROOF PLANGENERAL NOTES - ROOF PLAN1 CONTRACTOR TO REFER AND COORDINATE ALL PENETRATION REQUIREMENTSAND FLASHING DETAILS WITH MANUFACTURER'S RECOMMENDATIONS.2 ALL CRICKETS AND SADDLES SHALL BE CONSTRUCTED WITH MINIMUM 1/4" PER FT.SLOPED RIGID, TAPERED INSULATION AND SHALL BE SIZED AS INDICATED ON THEROOF PLANS UNLESS NOTED OTHERWISE.3 SOME MISCELLANEOUS STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICALROOF ITEMS REQUIRING ROOF FLASHING MAY NOT HAVE BEEN INDICATED ONROOF PLAN. REFER TO STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICALDRAWINGS AND FLASH PROPERLY IN ACCORDANCE WITH MANUFACTURER'SRECOMMENDATIONS.4 CONNECT ALL ROOF DRAINAGE TO CIVIL STORM SYSTEM.5 SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION ON ROOF DRAINSAND HVAC ROOF TOP UNITS.6 REFER TO ELECTRICAL AND MECHANICAL DRAWINGS FOR EQUIPMENTPLACEMENT, TYPE AND DETAILS. ALL EQUIPMENT SHOWN IS PLACED ON ROOFCURBING UNLESS NOTED OTHERWISE.7 THE FINAL PLACEMENT OF ALL EQUIPMENT AND PENETRATIONS SHOWN ON THISPLAN MAY VARY DUE TO COORDINATION BETWEEN TRADES AND ON SITECOORDINATION DURING CONSTRUCTION, AS WELL AS STRUCTUAL COORDINATION.8 TEMPORARY FALL PROTECTION IS NOT SHOWN AND IS THE SOLE RESPONSIBILITYOF THE CONTRACTOR.9 SEE STRUCTURAL DRAWINGS FOR TOP OF STEEL (T.O.S.) AT ALL PROPOSEDROOFS.10 VERIFY EXISTING CONDITIONS. WHEN DIMENSIONS AND/OR CONDITIONS ASINDICATED ON THE DRAWINGS CONFLICT WITH ACTUAL, CONTACT THE ARCHITECTFOR CLARIFICATION.FLAG NOTES - ROOF PLAN1 60 MIL. WHITE TPO ROOFING MEMBRANE OVER MIN. R-25 CONTINUOUS RIGIDINSULATION ON 5/8" EXTERIOR GRADE OSB SHEATHING O/ ROOF TRUSSES @ 24"O.C., SLOPE STRUCTURE TO DRAIN TOWARDS ROOF DRAINS / GUTTERS ANDMAINTAIN A 1/4" / 1-0" MIN. SLOPE. SEE BID ALTERNATE #1.2 1/4" / 1'-0" TAPERED INSULATION CRICKET.3 PARAPET WALL, REFER TO EXTERIOR ELEVATIONS AND WALL SECTIONS FOR HEIGHTOF PARAPET.4 ROOF ACCESS HATCH, ACCESSED VIA ALTERNATING TREAD LADDER LOCATEDWITHIN STAIRWELL. REFER TO STAIR SECTIONS AND PLANS.5 LAUNDRY CHUTE VENT.6 WALKWAY / PROTECTION PAD IN CONTRASTING COLOR TO ROOF FINISH MATERIAL.(TYP.)7 EXHAUST FAN, REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION.8 ROOF LEADER AND OVERFLOW DRAIN, REFER TO PLUMBING DRAWINGS FOR MOREINFORMATION.9 ROOF DRAIN, REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.10 ELEVATOR OVER RUN / PENTHOUSE, REFER TO ARCHITECTURAL SECTIONS FORMORE INFORMATION.11 METAL STOP EDGE.12 MECHANICAL EQUIPMENT ON ROOF CURB, REFER TO MECHANICAL DRAWINGS FORMORE INFORMATION.13 MECHANICAL EQUIPMENT SCREEN ATTACHED DIRECTLY TO EQUIPMENT (NOT ROOF)BY MECHANICAL CONTRACTOR, CITYSCAPES ENVISOR VERTICAL 70 OR EQUAL.SCREEN TO BE TALL ENOUGH TO FULLY HIDE EQUIPMENT, PROVIDE CLEARANCEAND ACCESS AS REQUIRED BY EQUIPMENT MANUFACTURER. CONTRACTOR TOCOORDINATE COLOR AND HEIGHT SELECTION WITH OWNER.14 ALTERNATING TREAD STAIR TO UPPER ROOF.15 EXTERIOR WALL MOUNTED CAMBRIA SIGNAGE, REFER TO ELECTRICAL DRAWINGSFOR POWER REQUIREMENTS.16 ROOF OF POOL BELOW.18 LOCATION OF KICKER19 COVERED ENTRY CANOPY BELOW.20 OUTLINE OF CONTINUOUS EXTERIOR GRADE TOWER ACCENT LIGHT BELOW.COORDINATE WITH PLANS, SECTIONS, ELEVATIONS, AND ELECTRICAL FOR MOREINFORMATION. LIGHT IS TO ILLUMINATE IN-SET METAL PANEL EC-6.BID ALTERNATE #1 - ROOF INSULATION:CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT INSULATION. (PER NFPA 13, A DRY SUPPRESSION SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO ROOF MANUFACTURER'S MINIMUM INSULATION/COVER BOARD (IF NEEDED).BID ALTERNATE #5 - LIGHTNING PROTECTION:CONTRACTOR TO PROVIDE DEDUCT ALTERNATE PRICE TO DELETE THE ENTIRE LIGHTNING PROECTION SYSTEM OUTLINED ON THE DRAWINGS AND PER SPECIFICATION SECTION 26 41 134 6/25/2018 BULLETIN #144
A
A
B
B
C
C
D
D
E
E
J
55
4
3
2
1
7
G
6
F
F
2.5
GWB
10'-0"
GWB
12'-0"
GWB
10'-0"
ACT
8'-6"
ACT
8'-6"
GWB
9'-0"
GWB
9'-6"
GWB
9'-0"
GWB
9'-0"
GWB
9'-0"
MGWB
10'-0"
GWB
9'-8"
ACT
9'-0"
GWB
9'-8"
ACT
9'-0"
ACT
9'-0"
GWB
9'-8"
ACT
9'-0"
GWB
10'-0"
ACT
11'-2"
ACT
11'-2"
9'-0"
GWB
9'-0"
GWB
10'-0"
A.3
B.5
B.5
7.2
2.8
K.8L.8
7.5
8.5
9
8.88.8
8
M
M
L
K.2
GWB
10'-0"10'-
6
"
GWB
10'-6"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
ACT
9'-0"
GWB
9'-0"
6'-0"16'-2 3/8"PROJECTOR LIFT
RECESSED
PROJECTION
SCREEN
GWB
9'-0"
GWB
8'-0"
PROJECTOR
POCKET
GWB
10'-0"
GWB
10'-0"
GWB
10'-0"
GWB
10'-0"
GWB
10'-0"
GWB
10'-0"
GWB
8'-0"
GWB
8'-0"GWB
8'-0"
GWB
8'-0"
GWB
8'-0"
GWB
8'-0"
EQEQEQEQ6'-5"30'-0"10'-5"6'-4 7/8"10'-0"10'-0"4'-6"4'-2"7'-0"7'-0"6'-0"5'-2 1/8"2'-8 3/4"5'-5"8'-0"7'-3"
2'-4"
1'-6 1/8"3'-0"1'-6 1/8"1'-0"3'-7"6'-7 1/8"3'-0"2'-5"5'-10 1/2"2'-0 1/4"2'-1"2'-4"7'-8"7'-8"6'-0"2'-0 3/4"3'-1 1/8"1'-6"3'-0"1'-6"1'-0 7/8"2'-2 3/4"
6'-6"6'-6"6'-6"
2'-8 3/8"3'-9 5/8"
3'-11 7/8"
3'-6 1/8"
2'-3"2'-0"4'-8"2'-0"EQEQ
GWB
10'-0"
MGWB
12'-6"
GWB
12'-6"
GWB
12'-6"
GWB
13'-4"
GWB
13'-4"
GWB
13'-4"
GWB
13'-4"
10'-0"5'-6"
GWB
8'-0"
A504
1
4'-0"4'-0"2'-9"PT-07
039
FITNESS CENTER 040
INDOOR
SWIMMING POOL
PT-07
PT-07
PT-07
WD-02
PT-07PT-07
PT-06
PT-08 PT-08
PT-08
PT-08
ACT-03
025
LAUNDRY
LAUNDRY
OFFICE
024
026
LINEN STOR.
153
STAIR B
023
MECH. RM
PT-08
027
LINEN CHUTE
ACT-02ACT-02
ACT-02
ACT-02
ACT-02
018
LOCKERS
017
BREAK RM
019
EMP. TLT
BOH
CORRIDOR
016
012
MEETING ROOM
022
ENG. OFFICE
015
FUNCTION STOR.
020
BEV. STOR.
ACT-02
PT-08
013
KITCHEN
PT-08
PT-06
WC-13
PT-06
PT-09
PT-06
PT-07 PT-07
PT-08 152
STAIR A
151
CORRIDOR
042
POOL MECH.
ROOM
041
POOL EQPM RM
102
KING 03
104
KING 01
106
DQ 04
108
ADA KING 02110
DQ 04
112
ADA KING 02
032
OFFICE
031
OFFICE
029
WORK AREA
034
DOS OFFICE
033
IT ROOM
010
COFFEE HOUSE
PUB
006
HANGOUT
003
WELCOME LOBBY
001
VESTIBULE
PT-06
002
CART
ACT-03
ACT-01 ACT-01 ACT-01 ACT-01PT-07 PT-07
PT-07PT-07GWB
8'-0"
GWB
8'-0"
ACT-02
PT-08
ACT-02ACT-02
ACT-02
037
CORRIDOR
038
STORAGE PT-07
PT-072'-4 1/8"3'-0"1'-6"1'-5"1'-5"
GWB
9'-6"
GWB
9'-4"
H.8 H.2 D.7
2.6
8.98.9
C.5
C.5
D.5
D.5
A.5
A.5
MGWB
10'-6"
MGWB
10'-0"
3.5
4.5
4.3
N
G9
8.7
6.2
6.3
B.3
PT-07
MGWB
12'-6"EQEQMGWB
8'-0"
043
MEN'S
DASHED LINE INDICATES CONTINUOUS 10 MIL
VAPOR BARRIER DIRECTLY BEHIND INTERIOR
GYPSUM BOARD. CONTRACTOR TO EXTEND THE
VAPOR BARRIER UP TO CEILING AND CONTINUE
ACROSS ENTIRE CEILING AREA. REFER TO FLOOR
PLANS AND SECTIONS FOR MORE INFORMATION.
EE
E E
GWB
9'-8"
EDGELESS COVE
LIGHTING, REFER TO
ELECTRICAL DRAWINGS.
EDGELESS COVE
LIGHTING, REFER TO
ELECTRICAL DRAWINGS.
POOL CEILING FINISH NOTE:
POOL CEILING IS TO HAVE A LEVEL 5
FINISH WITH EPOXY PAINT -COORDINATE
WITH INTERIOR DESIGN DRAWINGS.
GWB
7'-6"
GWB
7'-6"GWB
7'-6"EQ.EQ.GWB
12'-6"
EQ.EQ.
MGWB
8'-0"
044
WOMEN'S
PT-07
6'-5"18'-1 1/4"6'-5"
6
6
EQ.EQ.
WALL MOUNTED EMERGENCY LIGHT FIXTURE
EXTERIOR WALL PACK LIGHT
EXIT LIGHT
GYPSUM BOARD CEILING OR SOFFIT
NOTE: COORDINATE ARCHITECTURAL REFLECTED CEILING PLANS
WITH THE MECHANICAL AND ELECTRICAL DRAWINGS FOR
NUMBER OF, LOCATIONS OF, AND TYPES OF FIXTURES AND
GRILLES. NOT ALL ITEMS SHOWN ON LEGEND MAY BE PRESENT IN
PROJECT.
MILLWORK CEILING ELEMENT -
REFER TO ID DRAWINGS
2x2 LAY-IN ACOUSTICAL CEILING
INDICATES FIXTURE ON EMERGENCY CIRCUIT
(FIXTURE ALSO INDICATED WITH BLACK SHADE)E
EXIT LIGHT WITH EMERGENCY LIGHT HEADS
RCP LEGEND
GYPSUM BOARD CEILING OR
SOFFIT - MOISTURE RESISTANTTYP.6"5/8" GWB PAINTED FINISH,
EXTEND 6" ABOVE
CEILING TILES, TYP.
CORNER BEAD, TYP.
WOOD STUDS @ 16" O.C.
ACT & GRID
WOOD STUD TO
STRUCTURE ABOVE
TYP.4".SEE RCP .DIAGONAL BRACING
AS REQ'D, 48" O.C.
MAX
ACOUSTICAL
CEILING TILE OR
GWB
5/8" GWB (EXTEND ABOVE
ACT) ON WOOD STUDS @ 16"
O.C., EXTEND TO
STRUCTURE ABOVE
2x4 WOOD STUDS, ATTACH
TO INTERIOR PARTITION
CORNER BEAD -TYP.
WALL TYPE, SEE
PLANS
REFER TO RCPSEE RCP6"0 8' 16' 20'
1/8" = 1'-0"
12'
REVISIONS
N PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443331ST FLOOR RCPA111CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 060746 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A111
1 1ST FLOOR REFLECTED CLG PLAN
NOTE: SEE SHEETS A700-A713 FOR ENLARGED
GUESTROOM TYPE PLANS & ELEVATIONS.
GENERAL NOTES - RCP
1 FACE OF BULKHEADS SHALL ALIGN W. FACE OF ADJACENT WALLS TO WHICH
BULKHEADS ARE PARALLEL, U.N.O. OR DIMENSIONED.
2 CEILING GRIDS ARE CENTERED ON ROOM, U.N.O. OR DIMENSIONED.
3 COORDINATE ARCHITECTURAL REFLECTED CEILING PLANS WITH THE MECHANICAL
AND ELECTRICAL DRAWINGS FOR NUMBER OF, AND LOCATIONS OF, AND TYPES OF
FIXTURES AND GRILLES. NOT ALL ITEMS SHOWN ON LEGEND MAY BE PRESENT IN
PROJECT.
4 DOWNLIGHTS, DIFFUSERS, SPRINKLER HEADS, ETC. SHALL BE CENTERED IN
CEILING PANELS IN BOTH DIRECTIONS, UNLESS NOTED OTHERWISE.
5 WHERE EXIT SIGNS OCCUR OVER A DOOR OR PAIR OF DOORS, CENTER SIGN ON
DOOR OPENING.
6 PAINT DUCTWORK TO BLEND IN WITH CEILING WHERE EXPOSED, CEILING BEAMS
AND DECKING TO BE STAINED, COORDINATE COLOR WITH OWNER.
7 PROVIDE UNI-STRUT(S) UNDER DUCTWORK FOR HANGING LIGHT FIXTURES.
8 COORDINATE HEIGHTS OF ALL HANGING PENDANTS AND WALL SCONCES WITH
OWNER AT TIME OF INSTALLATION.
1 1/2" = 1'-0"A111
2 TYP. BULK HEAD
1 1/2" = 1'-0"A111
3 TYP. WALL SOFFIT
1
1 07/27/2016 ADD. #1
6 11/05/2018 BULLETIN #3
AABBCCDDEEHJ55432176F2.5ACT8'-0"GWB8'-6"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-0"ACT8'-0"ACT8'-4"205DQ 02207DQ 02209KING 01211DQ 02213DQ 02215KING 01203DQ 02201DQ 02202KING 03204KING 01206DQ 04208ADA KING 01210DQ 04212DQ 04214DQ 04216DQ 04218KING 01220KING 01222KING 02224ADA DQ 01226DQ 04228DQ 04230DQ 04232DQ 04234KING 01236KING 01238DQ 04240DQ 04239KING 01237DQ SUITE235DQ SUITE233DQ SUITE231DQ 022291 BR SUITE 03241KING 01ACT8'-0"ACT8'-0"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-4"GWB8'-4"GWB8'-0"GWB8'-4"GWB8'-4"GWB8'-4"B.5B.57.27.27.57.598.88.88MMLGWB8'-0"3'-10"2'-7 3/8"7'-0"7'-0"2'-2 7/8"2'-5 1/4"4'-6"4'-7"4'-6"2'-10"217ELEVATOR LOBBY223TELE/ DATA221VENDING225ELEC.219LINENPT-07GWB8'-0"GWB8'-0"GWB7'-6"GWB8'-0"GWB7'-6"GWB8'-0"GWB8'-0"GWB8'-0"ACT-01PT-07WC-05PT-08PT-07PT-08ACT-01PT-07PT-07PT-07ACT-01ACT-01GWB7'-6"GWB7'-6"GWB7'-6"252STAIR APT-08ACT-01ACT-01PT-07251CORRIDORGWB8'-0"GWB7'-6"GWB8'-0"GWB8'-0"ACT-01ACT-01ACT-01ACT-01PT-07PT-07PT-07PT-07242LINEN CHUTE253STAIR BPT-08PT-08GWB8'-4"GWB8'-11 5/8"GWB7'-6"GWB8'-0"GWB8'-0"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-0"H.8H.8H.2H.2GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-11 5/8"GWB8'-0"GWB8'-0"GWB8'-11 5/8"16'-4"11'-8"4'-8"D.78.98.9C.5C.5D.5D.5A.5A.53.54.5NMECHANICAL CONTRACTOR TOCOORINATE WITH FRAMERREGARDING SOFFIT HEIGHT FORMECHANICAL SUPPLY AT CORRIDOR.MECHANICAL CONTRACTOR TOCOORINATE WITH FRAMERREGARDING SOFFIT HEIGHT FORMECHANICAL SUPPLY AT CORRIDOR.OUTLINE OF CONTINUOUS VERTICAL EXTERIORGRADE TOWER ACCENT LIGHT. LIGHT IS TO EXTENDFROM FIRST FLOOR UP TO EC-4 BAND AT TOWER.COORDINATE WITH PLANS, SECTIONS, ELEVATIONS,AND ELECTRICAL FOR MORE INFORMATION.SHADED REGION IS THE INTENT FOR THE LIGHT TOILLUMINATE THE IN-SET METAL PANEL EC-6.WALL MOUNTED EMERGENCY LIGHT FIXTUREEXTERIOR WALL PACK LIGHTEXIT LIGHTGYPSUM BOARD CEILING OR SOFFITNOTE: COORDINATE ARCHITECTURAL REFLECTED CEILING PLANSWITH THE MECHANICAL AND ELECTRICAL DRAWINGS FOR NUMBEROF, LOCATIONS OF, AND TYPES OF FIXTURES AND GRILLES. NOTALL ITEMS SHOWN ON LEGEND MAY BE PRESENT IN PROJECT.MILLWORK CEILING ELEMENT -REFER TO ID DRAWINGS2x2 LAY-IN ACOUSTICAL CEILINGINDICATES FIXTURE ON EMERGENCY CIRCUIT(FIXTURE ALSO INDICATED WITH BLACK SHADE)EEXIT LIGHT WITH EMERGENCY LIGHT HEADSRCP LEGENDGYPSUM BOARD CEILING ORSOFFIT - MOISTURE RESISTANT0 8' 16' 20'1/8" = 1'-0"12'REVISIONSNPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443332ND FLOOR RCPA112CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 060747 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A11212ND FLOOR RELECTED CLG PLANNOTE: SEE SHEETS A700-A713 FOR ENLARGEDGUESTROOM TYPE PLANS & ELEVATIONS.GENERAL NOTES - RCP1 FACE OF BULKHEADS SHALL ALIGN W. FACE OF ADJACENT WALLS TO WHICHBULKHEADS ARE PARALLEL, U.N.O. OR DIMENSIONED.2 CEILING GRIDS ARE CENTERED ON ROOM, U.N.O. OR DIMENSIONED.3 COORDINATE ARCHITECTURAL REFLECTED CEILING PLANS WITH THE MECHANICALAND ELECTRICAL DRAWINGS FOR NUMBER OF, AND LOCATIONS OF, AND TYPES OFFIXTURES AND GRILLES. NOT ALL ITEMS SHOWN ON LEGEND MAY BE PRESENT INPROJECT.4 DOWNLIGHTS, DIFFUSERS, SPRINKLER HEADS, ETC. SHALL BE CENTERED IN CEILINGPANELS IN BOTH DIRECTIONS, UNLESS NOTED OTHERWISE.5 WHERE EXIT SIGNS OCCUR OVER A DOOR OR PAIR OF DOORS, CENTER SIGN ONDOOR OPENING.6 PAINT DUCTWORK TO BLEND IN WITH CEILING WHERE EXPOSED, CEILING BEAMS ANDDECKING TO BE STAINED, COORDINATE COLOR WITH OWNER.7 PROVIDE UNI-STRUT(S) UNDER DUCTWORK FOR HANGING LIGHT FIXTURES.8 COORDINATE HEIGHTS OF ALL HANGING PENDANTS AND WALL SCONCES WITHOWNER AT TIME OF INSTALLATION.1 7/27/2016 ADD. #11111
3 AABBCCDDEEHJ55432176F2.5B.5B.57.27.27.57.598.88.8L.68MML2'-7 1/2"7'-0"7'-0"2'-0 3/4"2'-10"4'-6"4'-7"4'-6"2'-3 1/4"3'-10"4'-8"7'-0"4'-8"ACT8'-0"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-0"ACT8'-0"ACT8'-4"GWB8'-0"GWB8'-0"GWB7'-6"305DQ 02307DQ 02309KING 01311KING 01313DQ 02315KING 01303DQ 02301DQ 02302KING 03304KING 01306DQ 04308ADA KING 01310DQ 04312DQ 04314DQ 04316DQ 04318KING 01320KING 013221 BR SUITE 023221 BR SUITE 023261 BR SUITE 01328DQ 04330ADA KING 01332DQ 04334KING 01336KING 01338DQ 04340DQ 04339KING 01337DQ SUITE331DQ 023291 BR SUITE 03341KING 01ACT8'-0"ACT8'-0"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-4"GWB8'-4"GWB8'-0"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-0"317ELEVATOR LOBBY323TELE/DATA321VEND'G325ELEC.319LINENPT-07GWB7'-6"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB7'-6"GWB7'-6"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB7'-6"GWB8'-0"GWB7'-6"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"ACT-01PT-07WC-05PT-08PT-07PT-08ACT-01PT-07PT-07PT-07ACT-01ACT-01GWB7'-6"GWB7'-6"352STAIR APT-08ACT-01ACT-01PT-07351CORRIDORGWB8'-0"GWB7'-6"GWB8'-0"GWB8'-0"ACT-01ACT-01ACT-01ACT-01PT-07PT-07PT-07PT-07340LINEN CHUTE353STAIR BPT-08PT-08GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"PT-07GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"H.8H.8H.2H.2GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"GWB8'-0"D.78.98.9C.5C.5D.5D.5A.5A.53.54.5N335DQ SUITE333DQ SUITEMECHANICAL CONTRACTOR TOCOORINATE WITH FRAMERREGARDING SOFFIT HEIGHT FORMECHANICAL SUPPLY AT CORRIDOR.MECHANICAL CONTRACTOR TOCOORINATE WITH FRAMERREGARDING SOFFIT HEIGHT FORMECHANICAL SUPPLY AT CORRIDOR.OUTLINE OF CONTINUOUS VERTICAL EXTERIORGRADE TOWER ACCENT LIGHT. LIGHT IS TO EXTENDFROM FIRST FLOOR UP TO EC-4 BAND AT TOWER.COORDINATE WITH PLANS, SECTIONS, ELEVATIONS,AND ELECTRICAL FOR MORE INFORMATION.SHADED REGION IS THE INTENT FOR THE LIGHT TOILLUMINATE THE IN-SET METAL PANEL EC-6.GWB8'-0"GWB8'-0"WALL MOUNTED EMERGENCY LIGHT FIXTUREEXTERIOR WALL PACK LIGHTEXIT LIGHTGYPSUM BOARD CEILING OR SOFFITNOTE: COORDINATE ARCHITECTURAL REFLECTED CEILING PLANSWITH THE MECHANICAL AND ELECTRICAL DRAWINGS FOR NUMBEROF, LOCATIONS OF, AND TYPES OF FIXTURES AND GRILLES. NOTALL ITEMS SHOWN ON LEGEND MAY BE PRESENT IN PROJECT.MILLWORK CEILING ELEMENT -REFER TO ID DRAWINGS2x2 LAY-IN ACOUSTICAL CEILINGINDICATES FIXTURE ON EMERGENCY CIRCUIT(FIXTURE ALSO INDICATED WITH BLACK SHADE)EEXIT LIGHT WITH EMERGENCY LIGHT HEADSRCP LEGENDGYPSUM BOARD CEILING ORSOFFIT - MOISTURE RESISTANT0 8' 16' 20'1/8" = 1'-0"12'REVISIONSNPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443333RD FLOOR RCPA113CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 060748 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A11313RD FLOOR REFLECTED CLG PLANNOTE: SEE SHEETS A700-A713 FOR ENLARGEDGUESTROOM TYPE PLANS & ELEVATIONS.GENERAL NOTES - RCP1 FACE OF BULKHEADS SHALL ALIGN W. FACE OF ADJACENT WALLS TO WHICHBULKHEADS ARE PARALLEL, U.N.O. OR DIMENSIONED.2 CEILING GRIDS ARE CENTERED ON ROOM, U.N.O. OR DIMENSIONED.3 COORDINATE ARCHITECTURAL REFLECTED CEILING PLANS WITH THE MECHANICALAND ELECTRICAL DRAWINGS FOR NUMBER OF, AND LOCATIONS OF, AND TYPES OFFIXTURES AND GRILLES. NOT ALL ITEMS SHOWN ON LEGEND MAY BE PRESENT INPROJECT.4 DOWNLIGHTS, DIFFUSERS, SPRINKLER HEADS, ETC. SHALL BE CENTERED IN CEILINGPANELS IN BOTH DIRECTIONS, UNLESS NOTED OTHERWISE.5 WHERE EXIT SIGNS OCCUR OVER A DOOR OR PAIR OF DOORS, CENTER SIGN ONDOOR OPENING.6 PAINT DUCTWORK TO BLEND IN WITH CEILING WHERE EXPOSED, CEILING BEAMS ANDDECKING TO BE STAINED, COORDINATE COLOR WITH OWNER.7 PROVIDE UNI-STRUT(S) UNDER DUCTWORK FOR HANGING LIGHT FIXTURES.8 COORDINATE HEIGHTS OF ALL HANGING PENDANTS AND WALL SCONCES WITHOWNER AT TIME OF INSTALLATION.1 7/27/2016 ADD. #111111
AABBCCDDEEHJ55432176F2.5B.5B.57.27.27.57.598.88.8L.6L.68MML2'-7 1/2"7'-0"7'-0"2'-2 3/4"2'-10"4'-6"4'-7"4'-6"2'-5 1/4"ACT8'-0"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-0"ACT8'-4"405DQ 02407DQ 02409KING 01411KING 01413DQ 02415KING 01403DQ 02401DQ 02402KING 03404KING 01406DQ 044081 BR SUITE ADA4121 BR SUITE 04414DQ 04416DQ 04418KING 01420KING 014221 BR SUITE 024221 BR SUITE 024261 BR SUITE 01428DQ 04430ADA KING 01432DQ 04434KING 01436KING 01438DQ 04440DQ 04439KING 01433DQ SUITE431DQ 024291 BR SUITE 03441KING 01ACT8'-0"ACT8'-0"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-0"GWB8'-4"ACT8'-4"GWB8'-4"GWB8'-0"GWB8'-4"GWB8'-4"GWB8'-4"GWB8'-0"417ELEVATOR LOBBY423TELE/ DATA421VEND'G425ELEC.419LINENPT-079'-0 3/8"GWB8'-0"GWB7'-6"GWB8'-0"GWB8'-0"9'-0 3/8"9'-0 3/8"ACT-01PT-07WC-05PT-08PT-07PT-08ACT-01PT-07PT-07PT-07ACT-01ACT-01452STAIR APT-08ACT-01ACT-01PT-07451CORRIDORACT-01ACT-01ACT-01ACT-01PT-07PT-07PT-07PT-07442LINEN CHUTE453STAIR BPT-08PT-089'-0 3/8"GWB8'-0"9'-0 3/8"9'-0 3/8"GWB8'-0"9'-0 3/8"GWB8'-0"9'-0 3/8"GWB8'-0"GWB8'-0"GWB7'-6"GWB8'-0"GWB8'-0"GWB7'-6"GWB7'-6"GWB8'-0"GWB8'-0"EQ.7'-0"EQ.3'-10"GWB9'-0 3/8"9'-0 3/8"9'-0 3/8"9'-0 3/8"GWB8'-0"GWB8'-0"H.8H.8H.2H.29'-0 3/8"GWB8'-0"GWB8'-0"9'-0 1/8"D.7D.78.98.9C.5C.5D.5D.5A.5A.53.54.5N435DQ SUITE437DQ SUITEGWB8'-0"MECHANICAL CONTRACTOR TO COORINATE WITH FRAMER REGARDING SOFFIT HEIGHT FOR MECHANICAL SUPPLY AT CORRIDOR.MECHANICAL CONTRACTOR TO COORINATE WITH FRAMER REGARDING SOFFIT HEIGHT FOR MECHANICAL SUPPLY AT CORRIDOR.OUTLINE OF CONTINUOUS VERTICAL EXTERIOR GRADE TOWER ACCENT LIGHT. LIGHT IS TO EXTEND FROM FIRST FLOOR UP TO EC-4 BAND AT TOWER. COORDINATE WITH PLANS, SECTIONS, ELEVATIONS, AND ELECTRICAL FOR MORE INFORMATION. SHADED REGION IS THE INTENT FOR THE LIGHT TO ILLUMINATE THE IN-SET METAL PANEL EC-6.WALL MOUNTED EMERGENCY LIGHT FIXTUREEXTERIOR WALL PACK LIGHTEXIT LIGHTGYPSUM BOARD CEILING OR SOFFITNOTE: COORDINATE ARCHITECTURAL REFLECTED CEILING PLANS WITH THE MECHANICAL AND ELECTRICAL DRAWINGS FOR NUMBER OF, LOCATIONS OF, AND TYPES OF FIXTURES AND GRILLES. NOT ALL ITEMS SHOWN ON LEGEND MAY BE PRESENT IN PROJECT.MILLWORK CEILING ELEMENT -REFER TO ID DRAWINGS2x2 LAY-IN ACOUSTICAL CEILINGINDICATES FIXTURE ON EMERGENCY CIRCUIT(FIXTURE ALSO INDICATED WITH BLACK SHADE)EEXIT LIGHT WITH EMERGENCY LIGHT HEADSRCP LEGENDGYPSUM BOARD CEILING OR SOFFIT - MOISTURE RESISTANT08'16'20'1/8" = 1'-0"12'REVISIONSNPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 443334TH FLOOR RCPA114CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 060749 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A11414TH FLOOR REFLECTED CLG PLANNOTE: SEE SHEETS A700-A713 FOR ENLARGED GUESTROOM TYPE PLANS & ELEVATIONS.GENERAL NOTES - RCP1 FACE OF BULKHEADS SHALL ALIGN W. FACE OF ADJACENT WALLS TO WHICHBULKHEADS ARE PARALLEL, U.N.O. OR DIMENSIONED.2 CEILING GRIDS ARE CENTERED ON ROOM, U.N.O. OR DIMENSIONED.3 COORDINATE ARCHITECTURAL REFLECTED CEILING PLANS WITH THE MECHANICALAND ELECTRICAL DRAWINGS FOR NUMBER OF, AND LOCATIONS OF, AND TYPES OFFIXTURES AND GRILLES. NOT ALL ITEMS SHOWN ON LEGEND MAY BE PRESENT INPROJECT.4 DOWNLIGHTS, DIFFUSERS, SPRINKLER HEADS, ETC. SHALL BE CENTERED INCEILING PANELS IN BOTH DIRECTIONS, UNLESS NOTED OTHERWISE.5 WHERE EXIT SIGNS OCCUR OVER A DOOR OR PAIR OF DOORS, CENTER SIGN ONDOOR OPENING.6 PAINT DUCTWORK TO BLEND IN WITH CEILING WHERE EXPOSED, CEILING BEAMSAND DECKING TO BE STAINED, COORDINATE COLOR WITH OWNER.7 PROVIDE UNI-STRUT(S) UNDER DUCTWORK FOR HANGING LIGHT FIXTURES.8 COORDINATE HEIGHTS OF ALL HANGING PENDANTS AND WALL SCONCES WITHOWNER AT TIME OF INSTALLATION.BID ALTERNATE #1 - ROOF INSULATION:CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT INSULATION. (PER NFPA 13, A DRY SUPPRESSION SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO ROOF MANUFACTURER'S MINIMUM INSULATION/COVER BOARD (IF NEEDED).111111 7/27/2016 ADD. #14 6/25/2018 BULLETIN #14
Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"ABCDEHJF12'-11 7/8"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"1A3001A300B.5ML1A4002A400W1RW1LW1RW1LW1LW1RW1RW1RW1RW1LW1LW1LW1RW1RW1RW1LW1LW1LW2RW2LW2RW2LW2RW2LW1RW1LW1LW1RW1RW1LW2LW2RW2RW1RW1RW1RW15W50011A401W1LW1LW1L3A4001A3011A301Truss Bearing45'-10 3/8"H.8H.2112A1687676769910112A1111112A12B515151515161616161617171712131412138818C.5D.5A.5N2ATYP2B2B1811181817164'-2"8'-4"4'-2"+/- 50'-5"+/- 58'-10"4A1883321212122EQEQ2223232323Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"54321762.5P1P26'-2 1/2"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"2A3002A30098Elevator roof52'-0 7/8"W5W15W1LW1LW1LW1RW1RW1RW1LW1LW1LW2R.1W2L.1W2R.1W2L.1W1LW1RW1RW1LW1RW1LW1RW1RW1RW1LW1LW1LW1RW2RW2L023BW1L016B2A3012A301Truss Bearing45'-10 3/8"11112A2A1332A56666777889910111111111112131415151515151616161616171717171818188.93.54.533184A1612B2B112A19TYP.19TYP.20202020553W1RW1LW1RW1L212122EQ.EQ.2323232323EXTERIOR FINISH MATERIAL LEGENDBLACK & WHITETAG #MATERIALEC-1COLORPOCHE' KEYEC-2EC-3METAL PANEL SYSTEMEC-4NOT USEDEC-5EIFSCOLOR: SW 7000 "IBIS WHITE"FINISH : SANDPEBBLE FINEEIFSCOLOR: SW 7038 "TONY TAUPE"FINISH : SANDPEBBLE FINEMETAL PANEL SYSTEMKYNAR COLOR : BRIGHT COPPERKYNAR COLOR : BONE WHITEEC-6ADHERED STONE VENEERENVIRONMENTAL STONEWORKS VENEERCOLOR: SOUTHERN LEDGESTONE "ASPEN"EC-7EIFSCOLOR: SW 7067 "CITYSCAPE"FINISH : SANDPEBBLE FINE0 8' 16' 20'1/8" = 1'-0"12'REVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333EXTERIOR ELEVATIONSA200CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607410 OF 4815815JUNE 24, 2016 1/8" = 1'-0"A2001SOUTH ELEVATION 1/8" = 1'-0"A2002WEST ELEVATIONGENERAL NOTES - ELEVATIONS1 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONS AND/ORCONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH ACTUAL, CONTACTTHE ARCHITECT FOR CLARIFICATION.2 REFER TO STRUCTURAL DETAILS FOR PROPER REINFORCEMENT OF MASONRY ATALL WINDOW AND DOOR OPENINGS, TYPICAL.3 REFER TO STRUCTURAL DETAILS FOR TYPICAL EXPANSION AND CONTROL JOINTCONSTRUCTION.FLAG NOTES - EXTERIOR ELEVATIONS1 STONE VENEER - ENVIRONMENTAL STONEWORKS. STYLE: SOUTHERNLEDGESTONE. COLOR: ASPEN. CONTACT BRIAN WILLIAMS AT THOMASBRICK 216-924-2480 bwilliams@thomasbrick.com2A 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.2B 2" EIFS (SANDPEBBLE FINE FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.3 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7067 "CITYSCAPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.4A 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7038 "TONY TAUPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.4B 2" EIFS (SANDPEBBLE FINE FINISH) - SW 7038 "TONY TAUPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION5 HORIZONTAL CONTROL JOINTS, TYPICAL6 CLEAR ANODIZED ALUMINUM STOREFRONT SYSTEM WITH THERMALBROKEN FRAME AND INSULATED GLAZING, REFER TO SPECIFICATIONS.7 SPANDREL ANODIZED ALUMINUM STOREFRONT SYSTEM WITH THERMALBROKEN FRAME AND INSULATED GLAZING, REFER TO SPECIFICATIONS.8 INSULATED METAL PANEL - BONE WHITE BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.9 INSULATED METAL PANEL - BRIGHT COPPER BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.10 WALL MOUNTED CAMBRIA SIGNAGE, WHITE PRIMARY COLOR WITH REDACCENT11 PREFABRICATED METAL VTAC LOUVRE - COLOR TO MATCH ADJACENTEXTERIOR FINISH, TYPICAL12 METAL COLUMN COVER - BONE WHITE BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION13 CANOPY STRUCTURE, REFER TO STRUCTURAL DETAILS FORADDITIONAL INFORMATION. PAINT TO MATCH EC-6 FINISH14 TRANSLUCENT CANOPY COVER - REFER TO ENLARGED DETAILS FORMORE INFORMATION.15 EIFS BAND (ROUGH FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION16 EIFS CORNICE / BAND (ROUGH FINISH) - SW 7000 "IBIS WHITE" BYWHERWIN WILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONSFOR ADDITIONAL INFORMATION17 PREFINISHED METAL COPING - COLOR TO MATCH EIFS/STONE/METALPANEL, TYP.18 EIFS 'V' REVEAL, REFER TO DETAILS FOR MORE INFORMATION.19 PREFABRICATED METAL MECHANICAL LOUVRE (SEE MECHANICALDRAWINGS FOR SIZE AND PRECISE LOCATION)- COLOR TO MATCHADJACENT EXTERIOR FINISH, TYPICAL20 OVERFLOW ROOF SCUPPER, PAINT TO MATCH FINISH. REFER TOPLUMBING AND ROOF PLANS FOR MORE INFORMATION.21 EXTERIOR GRADE LED STRIP LIGHT TO ILLUMINATE THE IN-SET EC-6METAL BAND. REFER TO PLANS, SECTIONS, DETAILS, AND ELECTRICALFOR MORE INFORMATION. THE VERTICAL LIGHT IS TO EXTEND FROMFIRST FLOOR TO TOP OF EIFS. HORIZONTAL LIGHT IS TO BE MOUNTEDON THE EIFS AND WRAP ALONG (3) SIDES OF TOWER.22 8FT LONG RECESSED EXTERIOR GRADE LED LIGHT CENTERED WITHINCOLUMN, COORDINATE WITH ELECTRICAL DRAWINGS FOR MOREINFORMATION.23 BUILDING UP-LIGHT TO ILLUMINATE VERTICAL STONE COLUMNS,MOUNTED ON TOP CORNICE. REFER TO WALL SECTIONS ANDELECTRICAL DRAWINGS FOR MORE INFORMATION.BID ALTERNATE #5 - LIGHTNING PROTECTION:CONTRACTOR TO PROVIDE DEDUCT ALTERNATE PRICE TODELETE THE ENTIRE LIGHTNING PROECTION SYSTEMOUTLINED ON THE DRAWINGS AND PER SPECIFICATIONSECTION 26 41 13
Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"ABCDE1A3001A300B.5M153A025BW3W3W3W9W11040BW1LW1LW1L1A3011A301Truss Bearing45'-10 3/8"H.8H.2D.711114B2A32A66W1RW1RW1RW1LW1LW1LW1RW1RW1R1111111115151515161616161717171818181818C.5D.5A.5N1A403W1RW1L15'-2"10'-9 3/8"10'-9 3/8"9'-1 5/8"+/- 4'-2"+/- 4'-2"+/- 50'-5"117162A4A4A4A204B1811174A2A19TYP201123Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"54321762.5Tower Reveal (Top)56'-8 7/8"2A3002A3007.27.598.88Elevator roof52'-0 7/8"W1LW1RW1RW1LW1LW1RW1RW1LW1RW1RW1LW1L012CW6016CW3W3W3151B152B1A4022A3012A301Truss Bearing45'-10 3/8"11112A2AW1LW1LW1LW1RW1RW1RW1LW1LW1L2A31111111115151515161616161616171717181818181812131488.93.54.515'-2"10'-9 3/8"10'-9 3/8"9'-1 5/8"6'-2 1/2"4'-8"011173116174A4A4A111112A2A2A2A19TYP19TYP12'-6"23EXTERIOR FINISH MATERIAL LEGENDBLACK & WHITETAG #MATERIALEC-1COLORPOCHE' KEYEC-2EC-3METAL PANEL SYSTEMEC-4NOT USEDEC-5EIFSCOLOR: SW 7000 "IBIS WHITE"FINISH : SANDPEBBLE FINEEIFSCOLOR: SW 7038 "TONY TAUPE"FINISH : SANDPEBBLE FINEMETAL PANEL SYSTEMKYNAR COLOR : BRIGHT COPPERKYNAR COLOR : BONE WHITEEC-6ADHERED STONE VENEERENVIRONMENTAL STONEWORKS VENEERCOLOR: SOUTHERN LEDGESTONE "ASPEN"EC-7EIFSCOLOR: SW 7067 "CITYSCAPE"FINISH : SANDPEBBLE FINE0 8' 16' 20'1/8" = 1'-0"12'REVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333EXTERIOR ELEVATIONSA201CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607411 OF 4815815JUNE 24, 2016 1/8" = 1'-0"A2011NORTH ELEVATION 1/8" = 1'-0"A2012EAST ELEVATIONGENERAL NOTES - ELEVATIONS1 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONS AND/ORCONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH ACTUAL, CONTACTTHE ARCHITECT FOR CLARIFICATION.2 REFER TO STRUCTURAL DETAILS FOR PROPER REINFORCEMENT OF MASONRY ATALL WINDOW AND DOOR OPENINGS, TYPICAL.3 REFER TO STRUCTURAL DETAILS FOR TYPICAL EXPANSION AND CONTROL JOINTCONSTRUCTION.FLAG NOTES - EXTERIOR ELEVATIONS1 STONE VENEER - ENVIRONMENTAL STONEWORKS. STYLE: SOUTHERNLEDGESTONE. COLOR: ASPEN. CONTACT BRIAN WILLIAMS AT THOMASBRICK 216-924-2480 bwilliams@thomasbrick.com2A 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.2B 2" EIFS (SANDPEBBLE FINE FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.3 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7067 "CITYSCAPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.4A 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7038 "TONY TAUPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.4B 2" EIFS (SANDPEBBLE FINE FINISH) - SW 7038 "TONY TAUPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION5 HORIZONTAL CONTROL JOINTS, TYPICAL6 CLEAR ANODIZED ALUMINUM STOREFRONT SYSTEM WITH THERMALBROKEN FRAME AND INSULATED GLAZING, REFER TO SPECIFICATIONS.7 SPANDREL ANODIZED ALUMINUM STOREFRONT SYSTEM WITH THERMALBROKEN FRAME AND INSULATED GLAZING, REFER TO SPECIFICATIONS.8 INSULATED METAL PANEL - BONE WHITE BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.9 INSULATED METAL PANEL - BRIGHT COPPER BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.10 WALL MOUNTED CAMBRIA SIGNAGE, WHITE PRIMARY COLOR WITH REDACCENT11 PREFABRICATED METAL VTAC LOUVRE - COLOR TO MATCH ADJACENTEXTERIOR FINISH, TYPICAL12 METAL COLUMN COVER - BONE WHITE BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION13 CANOPY STRUCTURE, REFER TO STRUCTURAL DETAILS FORADDITIONAL INFORMATION. PAINT TO MATCH EC-6 FINISH14 TRANSLUCENT CANOPY COVER - REFER TO ENLARGED DETAILS FORMORE INFORMATION.15 EIFS BAND (ROUGH FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION16 EIFS CORNICE / BAND (ROUGH FINISH) - SW 7000 "IBIS WHITE" BYWHERWIN WILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONSFOR ADDITIONAL INFORMATION17 PREFINISHED METAL COPING - COLOR TO MATCH EIFS/STONE/METALPANEL, TYP.18 EIFS 'V' REVEAL, REFER TO DETAILS FOR MORE INFORMATION.19 PREFABRICATED METAL MECHANICAL LOUVRE (SEE MECHANICALDRAWINGS FOR SIZE AND PRECISE LOCATION)- COLOR TO MATCHADJACENT EXTERIOR FINISH, TYPICAL20 OVERFLOW ROOF SCUPPER, PAINT TO MATCH FINISH. REFER TOPLUMBING AND ROOF PLANS FOR MORE INFORMATION.21 EXTERIOR GRADE LED STRIP LIGHT TO ILLUMINATE THE IN-SET EC-6METAL BAND. REFER TO PLANS, SECTIONS, DETAILS, AND ELECTRICALFOR MORE INFORMATION. THE VERTICAL LIGHT IS TO EXTEND FROMFIRST FLOOR TO TOP OF EIFS. HORIZONTAL LIGHT IS TO BE MOUNTEDON THE EIFS AND WRAP ALONG (3) SIDES OF TOWER.22 8FT LONG RECESSED EXTERIOR GRADE LED LIGHT CENTERED WITHINCOLUMN, COORDINATE WITH ELECTRICAL DRAWINGS FOR MOREINFORMATION.23 BUILDING UP-LIGHT TO ILLUMINATE VERTICAL STONE COLUMNS,MOUNTED ON TOP CORNICE. REFER TO WALL SECTIONS ANDELECTRICAL DRAWINGS FOR MORE INFORMATION.BID ALTERNATE #5 - LIGHTNING PROTECTION:CONTRACTOR TO PROVIDE DEDUCT ALTERNATE PRICE TODELETE THE ENTIRE LIGHTNING PROECTION SYSTEMOUTLINED ON THE DRAWINGS AND PER SPECIFICATIONSECTION 26 41 13
Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"5040CW102A301Truss Bearing45'-10 3/8"4.317'-6"15'-2"10'-9 3/8"10'-9 3/8"9'-1 5/8"12'-6"117162A6Floor 0215'-2"Floor 010"HJGFPAPBPCPD1A3001A300L10'-0"16'-0"10'-0"2'-11"10"2'-0"2'-10 1/2"1'-2"G9001W2RW1RW1LW1LW2L1131412131212128151532A812B2A1811662182322EQ.EQ.222222EXTERIOR FINISH MATERIAL LEGENDBLACK & WHITETAG #MATERIALEC-1COLORPOCHE' KEYEC-2EC-3METAL PANEL SYSTEMEC-4NOT USEDEC-5EIFSCOLOR: SW 7000 "IBIS WHITE"FINISH : SANDPEBBLE FINEEIFSCOLOR: SW 7038 "TONY TAUPE"FINISH : SANDPEBBLE FINEMETAL PANEL SYSTEMKYNAR COLOR : BRIGHT COPPERKYNAR COLOR : BONE WHITEEC-6ADHERED STONE VENEERENVIRONMENTAL STONEWORKS VENEERCOLOR: SOUTHERN LEDGESTONE "ASPEN"EC-7EIFSCOLOR: SW 7067 "CITYSCAPE"FINISH : SANDPEBBLE FINE"V-GROOVE" CONTROLJOINT, PAINT TO MATCH EIFSEXTERIOR GRADE SHEATHINGOVER 2x6 STUDS, REFER TOSTRUCTURER-21 BATT INSULATION,REFER TO WALL TYPES2"1"2" OR 3"VARIES3/4" EXPANSION JOINT INEIFS & SHEATHING W/SEALANT AND BACKER ROD,PAINT TO MATCH EIFS2"2" OR 3"VARIES5/8"EXTERIOR GRADE SHEATHINGOVER 2x6 STUDS, REFER TOSTRUCTURER-21 BATT INSULATION,REFER TO WALL TYPESEIFS BACKWRAP, TYP.EIFS BACKWRAP, TYP.Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"543212.5W8W61A4022A3012A301W1LW1LW1LW1RW1RW1RW1RW1RW1RW1LW1LW1LTruss Bearing45'-10 3/8"W1RW1RW1RW1LW1LW1LW1LW1LW1L3.54.5112A2A111111111515161616171818174A4A19TYP1912'-6"15'-2"10'-9 3/8"10'-9 3/8"9'-1 5/8"4'-2"4'-2"REVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333EXTERIOR ELEVATIONS & DETAILSA202CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607412 OF 4815815JUNE 24, 2016 1/4" = 1'-0"A2021EAST ELEVATION - POOL 1/4" = 1'-0"A2022SOUTH ELEVATION - PORTE COCHEREGENERAL NOTES - ELEVATIONS1 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONS AND/ORCONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH ACTUAL, CONTACTTHE ARCHITECT FOR CLARIFICATION.2 REFER TO STRUCTURAL DETAILS FOR PROPER REINFORCEMENT OF MASONRY ATALL WINDOW AND DOOR OPENINGS, TYPICAL.3 REFER TO STRUCTURAL DETAILS FOR TYPICAL EXPANSION AND CONTROL JOINTCONSTRUCTION. 3" = 1'-0"A2024REVEAL TYPES 1/8" = 1'-0"A2023WEST ELEVATION - OUTDOOR PATIO
EXTERIOR FINISH MATERIALLEGEND - COLORTAG #MATERIALEC-1COLORPOCHE' KEYEC-2EC-3METAL PANEL SYSTEMEC-4NOT USEDEC-5EIFSCOLOR: SW 7000 "IBIS WHITE"FINISH : SANDPEBBLE FINEEIFSCOLOR: SW 7038 "TONY TAUPE"FINISH : SANDPEBBLE FINEMETAL PANEL SYSTEMKYNAR COLOR : BRIGHT COPPERKYNAR COLOR : BONE WHITEEC-6ADHERED STONE VENEERENVIRONMENTAL STONEWORKS VENEERCOLOR: SOUTHERN LEDGESTONE "ASPEN"EC-7EIFSCOLOR: SW 7067 "CITYSCAPE"FINISH : SANDPEBBLE FINEEXTERIOR FINISH MATERIAL LEGENDBLACK & WHITETAG #MATERIALEC-1COLORPOCHE' KEYEC-2EC-3METAL PANEL SYSTEMEC-4NOT USEDEC-5EIFSCOLOR: SW 7000 "IBIS WHITE"FINISH : SANDPEBBLE FINEEIFSCOLOR: SW 7038 "TONY TAUPE"FINISH : SANDPEBBLE FINEMETAL PANEL SYSTEMKYNAR COLOR : BRIGHT COPPERKYNAR COLOR : BONE WHITEEC-6ADHERED STONE VENEERENVIRONMENTAL STONEWORKS VENEERCOLOR: SOUTHERN LEDGESTONE "ASPEN"EC-7EIFSCOLOR: SW 7067 "CITYSCAPE"FINISH : SANDPEBBLE FINEREVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333EXTERIOR 3D VIEWSA203CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607413 OF 4815815JUNE 24, 2016A20313D SOUTH CORNERA20323D EAST CORNERA20333D NORTH CORNERA20343D WEST CORNERFLAG NOTES - EXTERIOR ELEVATIONS1 STONE VENEER - ENVIRONMENTAL STONEWORKS. STYLE: SOUTHERNLEDGESTONE. COLOR: ASPEN. CONTACT BRIAN WILLIAMS AT THOMASBRICK 216-924-2480 bwilliams@thomasbrick.com2A 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.2B 2" EIFS (SANDPEBBLE FINE FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.3 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7067 "CITYSCAPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.4A 3" EIFS (SANDPEBBLE FINE FINISH) - SW 7038 "TONY TAUPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION.4B 2" EIFS (SANDPEBBLE FINE FINISH) - SW 7038 "TONY TAUPE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION5 HORIZONTAL CONTROL JOINTS, TYPICAL6 CLEAR ANODIZED ALUMINUM STOREFRONT SYSTEM WITH THERMALBROKEN FRAME AND INSULATED GLAZING, REFER TO SPECIFICATIONS.7 SPANDREL ANODIZED ALUMINUM STOREFRONT SYSTEM WITH THERMALBROKEN FRAME AND INSULATED GLAZING, REFER TO SPECIFICATIONS.8 INSULATED METAL PANEL - BONE WHITE BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.9 INSULATED METAL PANEL - BRIGHT COPPER BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION.10 WALL MOUNTED CAMBRIA SIGNAGE, WHITE PRIMARY COLOR WITH REDACCENT11 PREFABRICATED METAL VTAC LOUVRE - COLOR TO MATCH ADJACENTEXTERIOR FINISH, TYPICAL12 METAL COLUMN COVER - BONE WHITE BY KYNAR, REFER TOSPECIFICATIONS AND WALL SECTIONS FOR ADDITIONAL INFORMATION13 CANOPY STRUCTURE, REFER TO STRUCTURAL DETAILS FORADDITIONAL INFORMATION. PAINT TO MATCH EC-6 FINISH14 TRANSLUCENT CANOPY COVER - REFER TO ENLARGED DETAILS FORMORE INFORMATION.15 EIFS BAND (ROUGH FINISH) - SW 7000 "IBIS WHITE" BY SHERWINWILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONS FORADDITIONAL INFORMATION16 EIFS CORNICE / BAND (ROUGH FINISH) - SW 7000 "IBIS WHITE" BYWHERWIN WILLIAMS, REFER TO SPECIFICATIONS AND WALL SECTIONSFOR ADDITIONAL INFORMATION17 PREFINISHED METAL COPING - COLOR TO MATCH EIFS/STONE/METALPANEL, TYP.18 EIFS 'V' REVEAL, REFER TO DETAILS FOR MORE INFORMATION.19 PREFABRICATED METAL MECHANICAL LOUVRE (SEE MECHANICALDRAWINGS FOR SIZE AND PRECISE LOCATION)- COLOR TO MATCHADJACENT EXTERIOR FINISH, TYPICAL20 OVERFLOW ROOF SCUPPER, PAINT TO MATCH FINISH. REFER TOPLUMBING AND ROOF PLANS FOR MORE INFORMATION.21 EXTERIOR GRADE LED STRIP LIGHT TO ILLUMINATE THE IN-SET EC-6METAL BAND. REFER TO PLANS, SECTIONS, DETAILS, AND ELECTRICALFOR MORE INFORMATION. THE VERTICAL LIGHT IS TO EXTEND FROMFIRST FLOOR TO TOP OF EIFS. HORIZONTAL LIGHT IS TO BE MOUNTEDON THE EIFS AND WRAP ALONG (3) SIDES OF TOWER.22 8FT LONG RECESSED EXTERIOR GRADE LED LIGHT CENTERED WITHINCOLUMN, COORDINATE WITH ELECTRICAL DRAWINGS FOR MOREINFORMATION.23 BUILDING UP-LIGHT TO ILLUMINATE VERTICAL STONE COLUMNS,MOUNTED ON TOP CORNICE. REFER TO WALL SECTIONS ANDELECTRICAL DRAWINGS FOR MORE INFORMATION.111112A2A3335678910111213141516171819202020191917161612A34A56791011121314151617181112A2A615161616161717171812A34B6111516171819202017171616161716161515161711664B4A4A32A4A1114A12A2B34A67891011131415161718192020201917161616161682A2A11112B2B2B2B2B2A2A2B2B
Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"54321762.5P1P29'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"PORTE COCHERE001VESTIBULE003WELCOME LOBBY010COFFEE HOUSEPUB012MEETING ROOM016BOH CORRIDOR028ELEC.250CORR.350CORR.450CORR.220KING 01320KING 01420KING 012A3007.27.58.598.8810'-0"OPEN1A4022A301Truss Bearing45'-10 3/8"2513110426788899912214331112121213666666658A4004A40233.54.58.73Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"ABCDEHJGF1A3009'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"B.5L.6ML151CORRIDORElevator roof52'-0 7/8"251CORRIDOR351CORRIDOR451CORRIDOR003WELCOME LOBBY005MARKET1A301Truss Bearing45'-10 3/8"H.8H.2D.7C.5D.5A.52513110342678889991222331112121213666665856560A4004A4001N22REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333BUILDING SECTIONSA300CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607414 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A3001BUILDING SECTION - NORTH SOUTH 1/8" = 1'-0"A3002BUILDING SECTION - EAST WESTGENERAL NOTES - BUILDING SECTION1 REFER TO WALL SECTIONS AND DETAILS FOR DIMENSIONS AND ANNOTATIONS NOTSHOWN2 REFER TO CIVIL DRAWINGS FOR SITE UTILITY SIZES AND LOCATIONS3 REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION ONFOUNDATIONSFLAG NOTES - BUILDING SECTIONS1 APPROXIMATE FINISHED GRADE2 CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS3 CMU STEM WALL, GROUT SOLID, REFER TO STURCTURAL DRAWINGS4 THICKENED SLAB @ GUESTROOM NON-BEARING DEMISING WALLS, SEESTRUCTURAL DRAWINGS5 2x4 LAY-IN ACOUSTICAL CEILING TILES AND GRID, SEE RCP6 SUSPENDED GYPSUM CEILING, SEE RCP7 ROOF/ CEILING ASSEMBLY W/ PRE-ENGINEERED WOOD TRUSSES @ 24" O.C., SEESTRUCTURAL DRAWINGS8 ROOF FINISH, REFER TO ROOF PLAN9 FLOOR/ CEILING ASSEMBLY W/ FLOOR TJI JOISTS @ 16" O.C.10 MECHANICAL SCREEN, REFER TO ROOF PLAN11 ROOF/ CEILING ASSEMBLY W/ 2x8's @ 16" O.C., SEE STRUCTURAL DRAWINGS12 REFER TO TYPICAL UPPER FLOOR PLAN ON SHEETS A102, A102, & A104 FOREXTENT OF HORIZONTAL FLOOR/CEILING ASSEMBLIES 1 AND 2.13 2-HOUR FIRE RATED CEILING ASSEMBLY ABOVE ELEVATOR MACHINE ROOM 034.14 SUSPENDED MOISTURE RESISTANT GYPSUM BOARD CEILING OVER 10 MIL VAPORBARRIER, REFER TO RCPBID ALTERNATE #1 - ROOF INSULATION:CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT INSULATION. (PER NFPA 13, A DRY SUPPRESSION SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO ROOF MANUFACTURER'S MINIMUM INSULATION/COVER BOARD (IF NEEDED).4 6/25/2018 BULLETIN #14
Roof47'-11 1/8"Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"547Elevator Pit-5'-4"TOF-1'-4"6P1P22A3007.27.598.88Elevator roof52'-0 7/8"402KING 03302KING 03202KING 03102KING 03451CORRIDOR351CORRIDOR251CORRIDOR151CORRIDOR040INDOORSWIMMING POOL203DQ 02303DQ 02403DQ 022A301Truss Bearing45'-10 3/8"A40128.9A40133278111131112121213662358222A40324.54.36.26.3141414Roof47'-11 1/8"Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"ABCDEHJG1A3001A300A.3B.5K.8L.6MLElevator roof52'-0 7/8"2A4004A4001A4011A3011A301430ADA KING 01330ADA KING 01230DQ 04013KITCHEN250CORR.350CORR.450CORR.4291 BR SUITE 033291 BR SUITE 032291 BR SUITE 03010COFFEE HOUSEPUB042POOL MECH.ROOM040INDOORSWIMMING POOLTruss Bearing45'-10 3/8"BOF-4'-0"H.8H.2D.7C.5D.5A.5A40221B04278999111131112121213662323235A4002A4004N1A40314141414221REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333BUILDING SECTIONSA301CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607415 OF 4915815JUNE 24, 2016 1/8" = 1'-0"A3011BUILDING SECTION - THROUGH POOL 1/8" = 1'-0"A3012BUILDING SECTION - THROUGH POOLGENERAL NOTES - BUILDING SECTION1 REFER TO WALL SECTIONS AND DETAILS FOR DIMENSIONS AND ANNOTATIONS NOTSHOWN2 REFER TO CIVIL DRAWINGS FOR SITE UTILITY SIZES AND LOCATIONS3 REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION ONFOUNDATIONSFLAG NOTES - BUILDING SECTIONS1 APPROXIMATE FINISHED GRADE2 CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS3 CMU STEM WALL, GROUT SOLID, REFER TO STURCTURAL DRAWINGS4 THICKENED SLAB @ GUESTROOM NON-BEARING DEMISING WALLS, SEESTRUCTURAL DRAWINGS5 2x4 LAY-IN ACOUSTICAL CEILING TILES AND GRID, SEE RCP6 SUSPENDED GYPSUM CEILING, SEE RCP7 ROOF/ CEILING ASSEMBLY W/ PRE-ENGINEERED WOOD TRUSSES @ 24" O.C., SEESTRUCTURAL DRAWINGS8 ROOF FINISH, REFER TO ROOF PLAN9 FLOOR/ CEILING ASSEMBLY W/ FLOOR TJI JOISTS @ 16" O.C.10 MECHANICAL SCREEN, REFER TO ROOF PLAN11 ROOF/ CEILING ASSEMBLY W/ 2x8's @ 16" O.C., SEE STRUCTURAL DRAWINGS12 REFER TO TYPICAL UPPER FLOOR PLAN ON SHEETS A102, A102, & A104 FOREXTENT OF HORIZONTAL FLOOR/CEILING ASSEMBLIES 1 AND 2.13 2-HOUR FIRE RATED CEILING ASSEMBLY ABOVE ELEVATOR MACHINE ROOM 034.14 SUSPENDED MOISTURE RESISTANT GYPSUM BOARD CEILING OVER 10 MIL VAPORBARRIER, REFER TO RCPBID ALTERNATE #1 - ROOF INSULATION:CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT INSULATION. (PER NFPA 13, A DRY SUPPRESSION SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO ROOF MANUFACTURER'S MINIMUM INSULATION/COVER BOARD (IF NEEDED).4 6/25/2018 BULLETIN #14
Roof47'-11 1/8"Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"8.82'-0 3/4"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"8"6"11"6"104KING 01204KING 01304KING 01404KING 01Truss Bearing45'-10 3/8"TOP OF FINISHED LANDSCAPE2" PERIMETER INSULATIONSEALANT & BACKER ROD, TYP.FIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 2'-0"7'-0" - ROUGH OPENING3'-6"2'-0"10"1'-10"ROUGH OPENING6'-0"4'-9 3/8"6'-0" - ROUGH OPENING2'-1 3/4"8"1'-11 5/8"6'-0" - ROUGH OPENING5'-0 1/8"8"A4103A41011A4114E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.PT WOOD CANTWHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATION4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARDCONCRETE FOOTING, SEE STRUCTURAL DRAWINGSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSCEILING AS SCHEDULED, REFER TO RCP's AND ENLARGED GUESTROOM DETAILS.10'-0"DRIP EDGE, TYP.1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1'-9 3/4"ROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.CONTINUOUS METAL FLASHING, TYP.FIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1'-9 3/4"FIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1'-9 3/4"SOLID SURFACE SILL PER ID & FF&E REQUIREMENTS, TYP.8'-11 5/8"8'-11 5/8"9'-0 1/8"BOF-4'-0"8.9A4107A4104E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING11136"Roof47'-11 1/8"Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"TOF-1'-4"8"3"6'-8"2'-0 3/4"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"108ADA KING 02208ADA KING 01308ADA KING 014081 BR SUITE ADATruss Bearing45'-10 3/8"SEALANT & BACKER ROD2'-10"5'-0 3/8"2'-0"6'-0"2'-0"A4103A4108A41141'-10"10"2'-0"3'-6"7'-0"2'-0"EXPANSION JOINT w/ SEALANT & BACKER RODEXPANSION JOINT w/ SEALANT & BACKER RODMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARD5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATION2" PERIMETER INSULATION, EXTEND MINIMUM 4FTFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 1" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.WHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTCONCRETE FOOTING, SEE STRUCTURAL DRAWINGSCEILING AS SCHEDULED, REFER TO RCP's AND ENLARGED GUESTROOM DETAILS.DRIP EDGE, TYP.1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1'-9 3/4"5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATIONFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1'-9 3/4"FIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.ROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.FIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.FIXED ALUMINUM WINDOW w/ 1” INSULATED GLASSROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.FIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSEXPANSION JOINT w/ SEALANT & BACKER RODBOF-4'-0"10'-0"8'-11 5/8"8'-11 5/8"9'-0 1/8"8.96'-0"2'-9 3/8"2'-0"6'-0"2'-9 3/8"1'-9 3/4"A4106SimA4107A4101MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARD1113Roof47'-11 1/8"Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"4081 BR SUITE ADA308ADA KING 01208ADA KING 01108ADA KING 022'-0 3/4"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"Truss Bearing45'-10 3/8"TOP OF FINISHED LANDSCAPEEXPANSION JOINT w/ SEALANT & BACKER RODEXPANSION JOINT w/ SEALANT & BACKER RODMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARD5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATIONA4103A41062" PERIMETER INSULATIONFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.WHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTCONCRETE FOOTING, SEE STRUCTURAL DRAWINGSCEILING AS SCHEDULED, REFER TO RCP's AND ENLARGED GUESTROOM DETAILS.DRIP EDGE, TYP.1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATION10'-9 3/8"10'-9 1/8"9'-1 7/8"5'-10 3/4"2'-0"10"FIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1'-9 3/4"FIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1'-9 3/4"BOF-4'-0"A41079'-0 1/8"8.910"2'-0"12'-6"TYP.8'-11 5/8"8'-11 5/8"4'-0"1113Roof47'-11 1/8"Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"52'-0 3/4"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"Truss Bearing45'-10 3/8"DRIP EDGEA4103A4114A41141'-9 3/4"8"A41011SimTOP OF FINISHED LANDSCAPE2" PERIMETER INSULATIONFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.PT WOOD CANTWHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATION4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARDCONCRETE FOOTING, SEE STRUCTURAL DRAWINGSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSCEILING AS SCHEDULED, REFER TO RCP's AND ENLARGED GUESTROOM DETAILS.DRIP EDGE, TYP.1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGA4107E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGEXPANSION JOINT w/ SEALANT & BACKER RODEXPANSION JOINT w/ SEALANT & BACKER ROD1113REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333WALL SECTIONSA400CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607416 OF 4915815JUNE 24, 2016 1/2" = 1'-0"A4001Wall Section - Typ. 1/2" = 1'-0"A4002Wall Section - Center Bay @ Window 1/2" = 1'-0"A4003Wall Section - Center Bay 1/2" = 1'-0"A4004Wall Section - Typ. RearBID ALTERNATE #1 - ROOF INSULATION:CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT INSULATION. (PER NFPA 13, A DRY SUPPRESSION SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO ROOF MANUFACTURER'S MINIMUM INSULATION/COVER BOARD (IF NEEDED).4 6/25/2018 BULLETIN #144444
Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"Tower Reveal (Bot)55'-2 7/8"Tower Reveal (Top)56'-8 7/8"98.82'-0"1'-6"9'-4 1/2"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"4'-0"3'-11 1/4"3'-0"006HANGOUT224ADA DQ 014221 BR SUITE 02Truss Bearing45'-10 3/8"TOP OF FINISHED LANDSCAPEFOUNDATION & FTG -SEE STRUCT.PERIMETER INSUL.METAL COPINGMEMBRANE ROOF SYSTEM, FULLY ADHERED. EXTEND TO UNDERSIDE OF COPING OVER 1/2" OSB SHEATHING OVER 2x8 P.T. JOISTS AT 16" O.C.2x6 WOOD FRAMINGWALL MOUNTED, INTERNALLY ILLUMINATED SIGNBACKER ROD & SEALANT2x6 DIAGONAL BRACE. REFER TO STRUCT. DWGSCONTINUOUS EXTERIOR GRAD LED LIGHT FIXTUREWHITE TPO ROOFING MEMBRANE, FULLY ADHERED. EXTENDED TO UNDERSIDE OF COPING OVER MIN. 1" RIGID INSULATION OVER 1/2" OSB SHEATHING OVER 2x6 P.T. FRAMING @ 16" O.C.1'-0"3221 BR SUITE 022'-0"10'-0"1'-6"10'-6" ROUGH OPENING3'-2"1'-0"(CURTAIN WALL - REFER TO WINDOW SCHEDULE)32'-8" - ROUGH OPENING6'-4 7/8"A4112A4115A4115SimA4113BOF-4'-0"9'-0 3/8"8.9A41071/2" / 12"111FIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFloor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"5Low Roof14'-6"TOF-1'-4"2A301Truss Bearing45'-10 3/8"FOUNDATION & FTG -SEE STRUCT.CONC. SLAB -SEE STRUCT.PERIMETER INSUL.ALUM. STOREFRONT WINDOW5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD IN POOL OVER CONTINUOUS 10 MIL VAPOR BARRIER OVER 2x WOOD FRAMINGMET. FLASHINGEXPANSION JOINT W/SEALANT & BACKER RODEIFS (3" THICK) WITH AIR/MOISTURE BARRIER ON GYPSUM SHEATHING-TYP.2x6 WOOD FRAMING & STUDSR-21 BATT INSULATION, TYP.1/2" OSB SHEATHINGMETAL COPINGPREFINISHED METAL FLASHING TO MATCH EIFS COLORDRIP EDGEMEMBRANE ROOF SYSTEM, FULLY ADHERED. EXTEND TO UNDERSIDE OF COPINGTAPERED RIGID INSULATION TO DRAINEIFS BANDE.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.PT WOOD CANTWHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATIONFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASS1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGA4107RIM JOIST -REFER TO STRUCTURALA4121A41011SimA4114A4114A41224.310'-0"6"STEEL BEAM BEYOND, REFER TO STRUCTURAL FOR MORE INFORMATION. ENSURE BEAM IS FULLY COVERED W/ FIRE PROOFING.E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGMINIMUM R-30 INSULATION IN JOISTSPROVIDE CONTINUOUS 6" SOUND BATT INSULATION DIRECTLY ABOVE POOL CEILING AND BELOW GUEST ROOMS.5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER CONTINUOUS 10 MIL VAPOR BARRIER OVER EXTERIOR WALL ASSEMBLY (BEYOND) -REFER TO PLANS.040CTOP OF FINISHED LANDSCAPEPOOL DESIGN BY POOL CONTRACTOR, TYP.1113POOL CEILING FINISH NOTE:POOL CEILING IS TO HAVE A LEVEL 5 FINISH WITH EPOXY PAINT -COORDINATE WITH INTERIOR DESIGN DRAWINGS.Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"TOF-1'-4"8.8Truss Bearing45'-10 3/8"BOF-4'-0"SEALANT & BACKER RODEIFS BANDDRIP EDGEEXPANSION JOINT w/ SEALANT & BACKER RODDRIP EDGEEXPANSION JOINT w/ SEALANT & BACKER RODMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARD5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATION2" PERIMETER INSULATIONFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTCONCRETE FOOTING, SEE STRUCTURAL DRAWINGSCEILING AS SCHEDULED, REFER TO RCP's AND ENLARGED GUESTROOM DETAILS.DRIP EDGE, TYP.1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATIONFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.ROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.FIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.FIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.FIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSEXPANSION JOINT w/ SEALANT & BACKER RODPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.PT WOOD CANTWHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.A4107A4103A4114A41011SimA4104SimE.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING1113TOP OF FINISHED LANDSCAPEREVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333WALL SECTIONSA401CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607417 OF 4915815JUNE 24, 2016 1/2" = 1'-0"A4011WALL SECTION - TOWER 1/2" = 1'-0"A4012WALL SECTION - THROUGH POOL 1/2" = 1'-0"A4013TYP. WALL SECTIONBID ALTERNATE #1 -ROOF INSULATION:CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT INSULATION. (PER NFPA 13, A DRY SUPPRESSION SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO ROOF MANUFACTURER'S MINIMUM INSULATION/COVER BOARD (IF NEEDED).4 6/25/2018 BULLETIN #14444
Floor 0215'-2"Floor 010"G1A3001A300K.2012MEETING ROOM235DQ SUITEH.8H.2D.74'-0"15'-2"10'-0"1'-2"8"8"11'-2"2" PERIMETER INSULATIONSEALANT & BACKER ROD, TYP.4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARDFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSCEILING AS SCHEDULED, REFER TO RCP's AND ENLARGED GUESTROOM DETAILS.ROLLER TUBE & SHADE ASSEMBLY, REFER TO FF&E.DRIP EDGE, TYP.4'-0"1118"8"REFER TO SELECTED DIVIDING PARTITION MANUFACTURER FOR CONNECTION DETAILS8"5'-7 3/4"8"REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION. ENSURE ALL STEEL IS COMPLETLY COVERED WITH FIRE PROOFING PER G005, TYP.8"2"10"10'-0" - REFER TO STOREFRONT SCHEDULE1'-1"Floor 0215'-2"Floor 010"ATOF-1'-4"BOF-4'-0"2x6 WOOD FRAMING & STUDS1/2" OSB SHEATHINGMEMBRANE ROOF SYSTEM, FULLY ADHERED. EXTEND TO UNDERSIDE OF COPINGTAPERED RIGID INSUL. (MINIMUM THICKNESS OF R-25 INSULATION)A41075/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER CONTINUOUS 10 MIL VAPOR BARRIER OVER 2x WOOD FRAMING -REFER TO RCPPOOLMECH.ROOM0425/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER CONTINUOUS 10 MIL VAPOR BARRIER OVER EXTERIOR WALL ASSEMBLY -REFER TO PLANS.2" PERIMETER INSULATION4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARDSEALANT & BACKER ROD, TYP.DRIP EDGE, TYP.A4121MIRPOOL CEILING FINISH NOTE:POOL CEILING IS TO HAVE A LEVEL 5 FINISH WITH EPOXY PAINT -COORDINATE WITH INTERIOR DESIGN DRAWINGS.Floor 0215'-2"Floor 010"TOF-1'-4"P1P298.82'-5"5'-11"5'-10"11'-9"9'-11"130VESTIBULE220KING 01LIGHT FIXTURES ATTACHED TO STRUCTURAL STEEL FLANGE -REFER TO ELEC. DWGSROOF DRAINLVL -REFER TO STRUCTURALFOUNDATION & FOOTING -SEE STRUCTURALALUM. STOREFRONT DOORMET. FLASHINGEIFS (3" THK) WITH AIR/MOISTURE BARRIER ON GYPSUM SHEATHING-TYP.BATT INSULATIONMET. COPINGMEMBRANE ROOF SYSTEM, FULLY ADHERED . EXTEND TO UNDERSIDE OF COPINGTAPERED RIGID INSUL.FIXED ALUM. WINDOW W/ NAILFIN2X6 WOOD FRAMING5/8" GYPSUM SHEATHINGEIFS REVEAL-TYP.2X4 WOOD CEILING FRAMING5/8" GYPSUM BOARDFIRE RATED FLOOR/ CEILING ASSEMBLY. SEE SHEET G005EIFS (3" THK) WITH AIR/MOISTURE BARRIER ON GYPSUM SHEATHING-TYP.2X6 WOOD FRAMING & STUDS5/8" GYPSUM BOARDSTL TUBE FRAMING -PAINT TO MATCH EC-6CUSTOM STL FRAMING -PAINT TO MATCH EC-6METAL PANEL SYSTEM COLUMN SURROUND BEYOND -EC-6 -TYP.STL BEAMS -PAINT TO MATCH EC-6 -TYP. REFER TO STRUCT DWGSMETAL PANEL SYSTEM -EC-6 -TYP.MET. COPINGALUM. GUTTER AND DOWNSPOUT18'-0" R3" R2'-0"BOF-4'-0"TRANSLUCENT POLYCARBONATE GLAZING SYSTEM4'-0"2" PERIMETER INSULATION4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTENSURE ALL STEEL (NOT INCLUDING ENTRY CANOPY) IS COMPLETLY COVERED WITH FIRE PROOFING PER G005, TYP.REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333WALL SECTIONSA402CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607418 OF 4915815JUNE 24, 2016 1/2" = 1'-0"A4021WALL SECTION - MEETING ROOM 1/2" = 1'-0"A4022WALL SECTION - POOL 1/2" = 1'-0"A4023WALL SECTION - PORTE COCHERE ENTRY4 6/25/2018 BULLETIN #144
Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"TOF-1'-4"2A3007.27.5Truss Bearing45'-10 3/8"DOUBLE 2x6 P.T. BOTTOM PLATE (TYP.), REFER TO STRUCTURAL DRAWINGS FOR REQUIRED ANCHORS4" REINFORCED CONCRETE SLAB ON 10 MIL. VAPOR BARRIER, OVER 4"COMPACTED STONE, SEE STRUCTURAL DRAWINGS.5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER METAL FURRING (IN GUEST ROOMS). CONTRACTOR MAY ELECT TO USE WOOD FURRING.CORRIDOR SIDE5/8" TYPE 'X' GYPSUM BOARD OVER 1/2" RESILIENT CHANNEL (PROVIDE VERTICAL DRAFT STOPPING EVERY 10FT)GUEST ROOM SIDE (SEE WALL TYPES)5/8" TYPE 'X' GYPSUM BOARD OVER SHEATHING (IF REQUIRED) OVER 2x6 STUDS (SEE STRUCTURE) WITH 6" SOUND BATT INSULATION.5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER METAL FURRING (IN GUEST ROOMS). CONTRACTOR MAY ELECT TO USE WOOD FURRING.FINISH FLOOR & BASE AS SCHEDULEDFLOOR SYSTEM PER STRUCTURAL AND ASSEMBLIES -ENSURE JOIST CAVATIES ARE PROPERLY FIRE-BLOCKED.PROVIDE VERTICAL FIRE STOP AS REQUIRED5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER METAL FURRING (IN GUEST ROOMS). CONTRACTOR MAY ELECT TO USE WOOD FURRING.5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER METAL FURRING (IN GUEST ROOMS). CONTRACTOR MAY ELECT TO USE WOOD FURRING.CORRIDOR SIDE5/8" TYPE 'X' GYPSUM BOARD OVER 1/2" RESILIENT CHANNEL (PROVIDE VERTICAL DRAFT STOPPING EVERY 10FT)GUEST ROOM SIDE (SEE WALL TYPES)5/8" TYPE 'X' GYPSUM BOARD OVER SHEATHING (IF REQUIRED) OVER 2x6 STUDS (SEE STRUCTURE) WITH 6" SOUND BATT INSULATION.CONCRETE FOOTING, REFER TO STRUCTURAL DRAWINGS5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER METAL FURRING (IN GUEST ROOMS). CONTRACTOR MAY ELECT TO USE WOOD FURRING.CORRIDOR SIDE5/8" TYPE 'X' GYPSUM BOARD OVER 1/2" RESILIENT CHANNEL (PROVIDE VERTICAL DRAFT STOPPING EVERY 10FT)GUEST ROOM SIDE (SEE WALL TYPES)5/8" TYPE 'X' GYPSUM BOARD OVER SHEATHING (IF REQUIRED) OVER 2x6 STUDS (SEE STRUCTURE) WITH 6" SOUND BATT INSULATION.121121121343WHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGFloor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"5TOF-1'-4"Truss Bearing45'-10 3/8"2" PERIMETER INSULATIONFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 4" REINFORCED CONC. SLAB ON 10 MIL. VAPOR BARRIER OVER 4" COMPACTED STONE, SEE STRUCTURAL DRAWINGS1/2” FIBER EXPANSION JOINTCONCRETE FOOTING, SEE STRUCTURAL DRAWINGSFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSCEILING AS SCHEDULED, REFER TO RCP's AND ENLARGED GUESTROOM DETAILS.DRIP EDGE, TYP.1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.WHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 1" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS AT 16" O.C. W/ R-21 KRAFT FACED BATT INSULATIONFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSEXPANSION JOINT w/ SEALANT & BACKER RODFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHINGE.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 1" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGLVL - REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION.CONTINUOUS METAL FLASHING, TYP.FIXED ALUMINUM STOREFRONT W/ 1" INSULATED GLASSSOLID SURFACE SILL PER ID & FF&E REQUIREMENTS, TYP.EXTERIOR PATIO - REFER TO CIVIL AND LANDSCAPE DRAWINGS FOR MORE INFORMATION.5/8" GYPSUM BOARD OVER 2x6 WOOD STUDS @ 16" O.C. w/ R-21 KRAFT FACED BATT INSULATION.10"2'-0"5'-0 3/8"10'-0"10'-9 3/8"10'-7 3/8"10"2'-0"11'-6"1'-0"8"10"MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARDMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARD1113REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333WALL SECTIONSA403CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607419 OF 4915815JUNE 24, 2016 1/2" = 1'-0"A4032WALL SECTION - CORRIDOR 1/2" = 1'-0"A4031Wall Section - Typ. Rear HighBID ALTERNATE #1 - ROOF INSULATION:CONTRACTOR IS TO PROVIDE A SUPPRESSION DEDUCT ALTERNATE TO INSTALL BLOWN-IN INSULATION TO FILL THE ENTIRE ROOF CAVITY (MINIMUM R-38) IN LIEU OF THE ORIGINALLY SPECIFIED R-19 KRAFT-FACED BATT INSULATION. (PER NFPA 13, A DRY SUPPRESSION SYSTEM DOES NOT NEED TO BE INSTALLED W/IN THE ROOF JOIST SPACE IF THE CAVITY IS FILLED WITH INSULATION.) IN LIEU OF THE R-25 CONTINUOUS RIGID INSULATION ON THE ROOF, PROVIDE THE SELECTED TPO ROOF MANUFACTURER'S MINIMUM INSULATION/COVER BOARD (IF NEEDED).4 6/25/2018 BULLETIN #1444
Floor 0215'-2"7.57"1'-6"CORNER BEAD-TYP.2x BLOCKING AS REQUIRED5/8" GYPSUM BOARD 10'-0" A.F.F.2x4 WOOD FRAMING @ 16" O.C. -TYP.LED ROPE LIGHT FIXTURE -SEE ELEC. DWG1ENSURE ALL STEEL IS COMPLETLY COVERED WITH FIRE PROOFING PER G005, TYP.Floor 0215'-2"8.8DRIP EDGE, TYP.3/4" EXPANSION JOINT w/ SEALANT AND BACKER ROD, TYP.R-21 KRAFT-FACED BATT INSULATIONCONTINUOUS RIM JOIST, SEE STRUCTURE2x FRAMING AS REQUIREDDOUBLE 2x6 BOTTOM PLATE, TYP.DOUBLE 2x6 TOP PLATE, TYP.PREFINISHED METAL FLASHING TO MATCH E.I.F.S. COLOR2'-0"10"1'-9 3/4"DRIP EDGE, TYP.MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSUL. ON 5/8" GYPSUM BOARDEIFS FINISH BAND (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING OVER 2x FRAMINGEIFS FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING OVER 2x FRAMING8.94"2"8"1/2" / 12"6"5/8"5 1/2"1/2"2"WEB STIFFNERS TO ALIGN WITH STUDS BELOW16" SOUND BATT INSULATIONRoof47'-11 1/8"8.8Truss Bearing45'-10 3/8"2'-0 3/4"E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.WHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGTPO ROOFING TO CONTINUE UP & OVER PT WOOD KICKER, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.DOUBLE 2x6 TOP PLATE, TYP.AIR SPACE BELOW WOOD KICKERSR-21 INSULATION IN TOP CHORD OF ROOF TRUSS @ LOCATIONS w/ WOOD KICKERSCONTINUOUS R-21 KRAFT FACED BATT INSULATION AT ALL EXTERIOR WALLS, TYP.PREMANUFACTURED WOOD ROOF TRUSSES @ 24" O.C. (SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION)8.9"SINK" PARAPET WALL DOWN TO DOUBLE TOP PLATES BELOW, TYP.CONTINUOUS 2x10, REFER TO STRUCTUREDRIP EDGE, TYP.3Floor 010"TOF-1'-4"BOF-4'-0"MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 7/16" EXERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INULATION ON 5/8" GYPSUM BOARD(2) P.T. 2x6 SILL PLATES ON SILL SEAL @? 5/8" DIA. ANCHOR BOLTS -18" LONG w/ 2" HOOKS, 32" O.C. MAX AND @ ALL CORNERS1/2" EXPANSION JOINT FILLERCONCRETE SLAB: 4" POURED CONCRETE SLAB WITH 6x6 W1.4xW1.4WF REINFORCING ON VAPOR CHECK 10 MIL. VAPOR BARRIER ON 4" GRANULAR FILL ON WELL COMPACTED EARTH, SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION2" THICK CONTINUOUS RIGID EPS PERIMETER INSULATION, EXTEND A MINIMUM OF 4FT INTO THE BUILDING UNDER THE SLAB, TYP.POURED TRENCH FOOTING, SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATIONREINFORCING, SEE STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION(1) COURSE 6"x8"x16" CMU FOUNDATION WALL, GROUT CELLS SOLID. ALIGN CENTER OF CMU WITH CENTER OF CONCRETE FOOTING. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION8.94"2"4"2'-0"2'-8"8"8"Roof47'-11 1/8"8.8Truss Bearing45'-10 3/8"8.95/8" EXTERIOR OSB SHEATHING OVER ROOF TRUSSES, REFER TO STRUCTUREDOUBLE 2x6 TOP PLATE, TYP.R-21 KRAFT FACED BATT INSULATION AT ALL EXTERIOR WALLS, TYP.PREMANUFACTURED WOOD ROOF TRUSSES @ 24" O.C. (SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION)E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING40 MIL. THRU-WALL FLEXIBLE FLASHING, SEALED AND ADHERED TO ARCHED STEEL ANGLE, SET IN MASTIC OR SEALANT. PROVIDE WEEP VENTS AT 24" HORIZ.WOOD HEADER PER STRUCTURAL DRAWINGS1" ALUMINUM STOREFRONT WINDOW SYSTEM, SEE EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSULATION3/4" EXPANSION JOINT w/ SEALANT AND BACKER ROD, TYP.R-21 INSULATION IN TOP CHORD OF ROOF TRUSS @ LOCATIONS w/ WOOD KICKERS3Roof47'-11 1/8"8.8Truss Bearing45'-10 3/8"2'-0 3/4"1'-10"8"3"6"PREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.WHITE TPO ROOFING MEMBRANE OVER R-25 MIN. RIGID INSULATION ON 5/8" EXTERIOR OSB SHEATHINGDOUBLE 2x6 TOP PLATE, TYP.R-21 KRAFT FACED BATT INSULATION AT ALL EXTERIOR WALLS, TYP.PREMANUFACTURED WOOD ROOF TRUSSES @ 24" O.C. (SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION)2x WOOD FRAMING6" PT WOOD CANTTPO ROOFING TO CONTINUE UP & OVER PT WOOD CANT, OVER 5/8" EXTERIOR OSB SHEATHING OVER 2x6 WOOD STUDS AT 16" O.C.. REFERENCE DETAIL 4/A412 FOR REQUIREMENTS WHEN TRANSITIONING FROM HORIZONTAL TO VERTICAL MEMBRANE.E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING40 MIL. THRU-WALL FLEXIBLE FLASHING, SEALED AND ADHERED TO ARCHED STEEL ANGLE, SET IN MASTIC OR SEALANT. PROVIDE WEEP VENTS AT 24" HORIZ.WOOD HEADER PER STRUCTURAL DRAWINGS1" ALUMINUM STOREFRONT WINDOW SYSTEM, SEE EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.8.938.91" ALUMINUM STOREFRONT WINDOW SYSTEM, SEE EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.SOLID SURFACE SILL PER CHOICE STANDARDS, TYP AT ALL WINDOWS U.N.O.SEALANT & BACKER ROD, TYPMETAL FLASHING, SINGLE LAPPED WITH MOISTURE BARRIER MEMBRANES, TYP.5/8"5 1/2"1/2"EXTERIOR FINISH (SEE ELEVATIONS) ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS @ 16" O.C. -REFER TO STRUCTURE.Floor 0436'-8 3/4"8.88.9EIFS FINISH BAND (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING OVER 2x FRAMINGDRIP EDGEFIRE RATED FLOOR/CEILING ASSEMBLY. SEE SHEET G005 1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING3/4" EXPANSION JOINT w/ SEALANT AND BACKER ROD, TYP.PREFINISHED METAL FLASHING TO MATCH E.I.F.S. COLOREIFS FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING OVER 2x FRAMINGR-21 KRAFT-FACED BATT INSULATIONCONTINUOUS RIM JOIST, SEE STRUCTUREDOUBLE 2x6 BOTTOM PLATE, TYP.DOUBLE 2x6 TOP PLATE, TYP.1" / 12"5/8"5 1/2"1/2"3"6"6"8"6" SOUND BATT INSULATIONREVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333SECTION DETAILSA410CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607420 OF 4915815JUNE 24, 2016 1" = 1'-0"A4102CEILING DETAIL - WELCOME LOBBY 1 1/2" = 1'-0"A4103LARGE CORNICE DETAIL 1 1/2" = 1'-0"A4106TYPICAL HIGH PARAPET DETAIL 1 1/2" = 1'-0"A4107FOOTING @ FIRST FLOOR STUD WALL (STONE) 1 1/2" = 1'-0"A4108TYPICAL HIGH PARAPET REVEAL DETAIL 1 1/2" = 1'-0"A41011TYPICAL LOW PARAPET DETAIL 1 1/2" = 1'-0"A4101TYPICAL EXTERIOR SILL DETAIL 1 1/2" = 1'-0"A41048" BAND DETAIL4 6/25/2018 BULLETIN #1444
5R-21 KRAFT-FACED BATT INSULATIONSIDE MOUNTED ROLLER TUBE AND SHADE ASSEMBLY WITH DOUBLE SHADE, TYP.LINE OF VTAC ACCESS PANEL ON WALL BEYOND, SHOWN FOR REFERENCE ONLY3 1/4"GLAZING AS SCHEDULEDALUMINUM WINDOW FRAME WITH NAILFINCONTINUOUS WEATHERTIGHT SEALANTEIFS SYSTEMFLUID APPLIED AIR & MOISTURE BARRIER, TURN INTO OPENING, CONTINUOUS AT ALL SIDESPT WOOD SHIM1/2"" EXTERIOR GRADE OSB SHEATHINGDRIP EDGEHEM BAR SEALED INSIDE CLOTHBLACKOUT SHADE IN DOWN POSITIONLINE OF SHADE TRACK BEYONDFABRIC COVERED INTEGRAL VALENCE, REFER TO ID DRAWINGS FOR ADDT'L INFO.VISUAL SCREEN SHADE IN DOWN POSITIONMETAL FLASHING TO MATCH WINDOW FRAME11 5/8"HEADER PER STRUCTURAL DRAWINGSTower Reveal (Bot)55'-2 7/8"Tower Reveal (Top)56'-8 7/8"98.8Truss Bearing45'-10 3/8"4'-0"3'-11"3'-0"6'-5"1'-6"2'-0"MEMBRANE ROOF SYSTEM, FULLY ADHERED. EXTEND TO UNDERSIDE OF COPING OVER 3/4" OSB SHEATHING OVER 2x8 P.T. JOISTS AT 16" O.C.2x JOISTS, REFER TO STRUCTURALWALL MOUNTED, INTERNALLY ILLUMINATED SIGN BY OTHERS, G.C. TO COORDINATE. E.C. TO PROVIDE ALL NECESSARY POWER.BACKER ROD & SEALANT2x6 DIAGONAL BRACING AS REQUIRED, REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.DRIP EDGEE.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH METAL BAND COLOR BELOW, TYP. EXTEND ROOF MEMBRANE UP AND OVER WALL, TYP.CONTINUOUS VENTMETAL FLASHING, EXTEND MEMBRANE UP AND OVER 2x8CANT STRIPINSULATED METAL PANEL ACCENT BAND OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING.SPANDREL GLAZING, REFER TO WINDOW ELEVATIONS FOR ADDITIONAL INFORMATION. ALUMINUM CURTAIN WALL SYSTEM, REFER TO GLAZING ELEVATIONS & DETALSHSS BEAM, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. BEAM IS TO BE COVERED ENTIRELY W/ FIRE PROOFING (TYP) AS NOTED IN DETAILS ON G005.PROVIDE 2" RIGID INSULATION BEHIND ALL SPANDREL GLAZING, TYP. BLACKOUT ROLLER SHADESHEER ROLLER SHADEMETAL FLASHING WITH 6" VERTICAL LEG, SINGLE LAPPED WITH MOISTURE BARRIER MEMBRANESPREFINISHED METAL FLASHING TO MATCH E.I.F.S. COLORBACKER ROD & SEALANTMEMBRANE ROOF SYSTEM, FULLY ADHERERED OVER FLUID APPLIED MOISTURE/AIR BARRIER OVER 1/2" EXTERIOR GRADE OSB SHEATHING OVER 2x6 FRAMING.DOUBLE 2x TOP PLATE, TYP.8.91/2" / 12" MIN.1" / 12"HSS COLUMN BEYOND, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. COLUMN IS TO BE WITHIN 1-HR RATED ASSEMBLY OR ENTIRELY COVERED W/ FIRE PROOFING AS SHOWN IN DETAILS ON G00510'-2"9"1/2" / 12"PROVIDE SOLID BLOCKING BEHIND LOCATION OF SIGN(S), COORDINATE WITH SIGN MANUFACTURER AND INSTALLER.3'-9"5 1/2"1'-2 1/4"4'-3"CONTINUOUS EXTERIOR GRADE LIGHT FIXTURE TO ILLUMINATE THE METAL PANEL - REFER TO EXTERIOR ELEVATIONS AND ELECTRICAL DRAWINGS FOR MORE INFORMATION.WITH MANUF.± 8" - VERIFY9"ENSURE FACE OF METAL PANEL (EC-6) ALIGNS WITH VERTICAL EC-6, REFER TO PLAN DETAILS AND ELEVATIONS.3Floor 0215'-2"96" ALUMINUM CURTAIN WALL SYSTEM, REFER TO GLAZING ELEVATIONS & DETALSHSS BEAM, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. BEAM IS TO BE WITHIN 1-HR RATED FLOOR/CEILING ASSEMBLY OR ENTIRELY COVERED W/ INTUMNESCENT PAINT, TYP.INSULATED METAL PANEL ACCENT BAND OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGPREFINISHED METAL FLASHING TO MATCH E.I.F.S. COLOR2x FRAMING @ 16" O.C.HSS COLUMN BEYOND, REFER TO PLANS2'-0"1'-0" CLEARPROVIDE SOLID 2x BLOCKING WITH INSULATION AROUND HSS BEAM, TYP.6" ALUMINUM CURTAIN WALL SYSTEM, REFER TO GLAZING ELEVATIONS & DETALS1R-21 KRAFT-FACED BATT INSULATIONHSS COLUMN BEYOND, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. COLUMN IS TO BE WITHIN 1-HR RATED ASSEMBLY OR ENTIRELY COVERED W/ INTUMNESCENT PAINT, TYP.HSS COLUMN BEYOND, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. COLUMN IS TO BE WITHIN 1-HR RATED ASSEMBLY OR ENTIRELY COVERED W/ INTUMNESCENT PAINT, TYP.Floor 0325'-11 3/8"9SPANDREL GLAZING, REFER TO WINDOW ELEVATIONS FOR ADDITIONAL INFORMATION. 6" ALUMINUM CURTAIN WALL SYSTEM, REFER TO GLAZING ELEVATIONS & DETALSHSS BEAM, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. BEAM IS TO BE WITHIN 1-HR RATED FLOOR/CEILING ASSEMBLY OR ENTIRELY COVERED W/ INTUMNESCENT PAINT, TYP.PROVIDE 2" RIGID INSULATION BEHIND ALL SPANDREL GLAZING, TYP. BLACKOUT ROLLER SHADESHEER ROLLER SHADE1/2"PROVIDE 1/2" AIR GAP BETWEEN CURTAIN WALL AND 2x4 WALL FRAMING @ 3rd & 4th FLOORS1R-15 KRAFT-FACED BATT INSULATIONPROVIDE SOLID-SURFACE SILL, REFER TO CAMBRIA STANDARDS.HSS COLUMN BEYOND, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. COLUMN IS TO BE WITHIN 1-HR RATED ASSEMBLY OR ENTIRELY COVERED W/ INTUMNESCENT PAINT, TYP.HSS COLUMN BEYOND, REFER TO STRUCTURAL DRAWINGS FOR SIZING AND ADDITIONAL INFORMATION. COLUMN IS TO BE WITHIN 1-HR RATED ASSEMBLY OR ENTIRELY COVERED W/ FIRE PROOFING AS SHOWN IN DETAILS ON G005PROVIDE SOLID FIRE STOPPING BETWEEN FLOORS, TYP.Floor 0325'-11 3/8"8.82'-9 3/8"8.9DOUBLE 2x6 TOP PLATE, TYP.40 MIL. THRU-WALL FLEXIBLE FLASHING, SEALED AND ADHERED TO ARCHED STEEL ANGLE, SET IN MASTIC OR SEALANT. PROVIDE WEEP VENTS AT 24" HORIZ.WOOD HEADER PER STRUCTURAL DRAWINGS1" ALUMINUM STOREFRONT WINDOW SYSTEM, SEE EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.STRUCTURAL RIM JOIST, REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATIONDOUBLE 2x6 BOTTOM PLATE, TYP.BLACKOUT ROLLER SHADESHEER ROLLER SHADE1 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING1EXPANSION JOINT, TYP.R-21 KRAFT-FACED BATT INSULATION, TYP.REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333SECTION DETAILSA411CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607421 OF 4915815JUNE 24, 2016 3" = 1'-0"A4111TYP. GUESTROOM WINDOW HEAD DETAIL 1 1/2" = 1'-0"A4113TYP. TOWER CORNICE DETAIL 1 1/2" = 1'-0"A4112TYP. TOWER SECOND FLOOR DETAIL 1 1/2" = 1'-0"A4115TYP. TOWER UPPER FLOOR DETAIL 1 1/2" = 1'-0"A4114TYPICAL UPPER FLOOR DETAIL4 6/25/2018 BULLETIN #1444
RIGID INSULATIONSUBSTRATEWALL / PARAPETULTRAPLY TPO MEMBRANEULTRAPLY TPO BONDING ADHESIVEQUICKSEAM RPF STRIP (SEE NOTE #4)ULTRAPLY TPO QUICKPRIMEULTRAPLY TPO BONDING ADHESIVE (SEE NOTE #5)QUICKSEAM RPF STRIP MUST EXTEND1/2" (13 mm) BEYOND 2" METAL OR HDSEAM PLATE (SEE NOTE #4)NOTES:1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENTINFORMATION.2. MAXIMUM 6" (152 mm) LONG FASTENERS. (NOTE:WOOD BLOCKING MAY BE SUBSTITUTED FORINSULATION TO REDUCE FASTENER LENGTHREQUIREMENTS.)3. IN CASE OF OBSTRUCTION REFER TO DETAIL UT-BT-6.4. REFER TO UT-BT-14 & UT-BT-15 FOR QUICKSEAM RPFSTRIP LAYOUT AT CORNERS.5. BONDING ADHESIVE REQUIRED BETWEEN MEMBRANEAND INSULATION FOR FULLY ADHERED SYSTEMS.6. BATTEN STRIPS MAY BE USED IN LIEU OF METALPLATES FOR MAS AND FULLY ADHERED SYSTEMSONLY.FIRESTONE FASTENER AND 2" METALPLATE OR HD SEAM PLATE@ 12" (305 mm) O.C. MAX. (SEE NOTE #3)Floor 0215'-2"1" ALUMINUM STOREFRONT WINDOW PER SCHEDULEMETAL FLASHINGEXPANSION JOINT W/SEALANT & BACKER ROD1/2" EXTERIOR GRADE OSB SHEATHING, EACH SIDE OF PARAPET.PREFINISHED METAL FLASHING TO MATCH EIFS COLORDRIP EDGEMEMBRANE ROOF SYSTEM, FULLY ADHERED. EXTEND TO UNDERSIDE OF COPINGTAPERED RIGID INSULATIONEIFS BANDLVL -REFER TO STRUCTURAL4.32'-0"10"8"PREFINISHED METAL COPING OVER PT WOOD NAILER, METAL TO MATCH E.I.F.S. COLOR, TYP.MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING, ON 2x6 WOOD STUDS AT 16" O.C. w/ R-21 KRAFT FACED BATT INSULATION5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER CONTINUOUS 10 MIL VAPOR BARRIER OVER 2x WOOD FRAMING -REFER TO RCP5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER CONTINUOUS 10 MIL VAPOR BARRIER OVER EXTERIOR WALL ASSEMBLY -REFER TO PLANS.POOL CEILING FINISH NOTE:POOL CEILING IS TO HAVE A LEVEL 5 FINISH WITH EPOXY PAINT -COORDINATE WITH INTERIOR DESIGN DRAWINGS.Floor 0215'-2"51 1/4” GYPCRETE OVER 3/4” T&G OSB FLOOR SHEATHING5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM BOARD OVER CONTINUOUS 10 MIL VAPOR BARRIER OVER 2x WOOD FRAMING -REFER TO RCPFIXED ALUMINUM WINDOW W/ 1” INSULATED GLASSSTEEL BEAM BEYOND, REFER TO STRUCTURAL FOR MORE INFORMATION. ENSURE BEAM IS FULLY COVERED W/ FIRE PROOFING.PROVIDE CONTINUOUS 6" SOUND BATT INSULATION DIRECTLY ABOVE POOL CEILING AND BELOW GUEST ROOMS.TAPERED INSULATION, SLOPE TOWARDS DRAIN(S) -REFER TO ROOF PLANSEXTEND ROOF MEMBRANE UNDER WALL FINISH, MINIMUM OF 6"POOL CEILING FINISH NOTE:POOL CEILING IS TO HAVE A LEVEL 5 FINISH WITH EPOXY PAINT -COORDINATE WITH INTERIOR DESIGN DRAWINGS.REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333SECTION DETAILSA412CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607422 OF 4915815JUNE 24, 2016 1" = 1'-0"A4121POOL PARAPET DETAIL 1" = 1'-0"A4122LOW ROOF FLASHING DETAIL 6" = 1'-0"A4124ROOFING @ PARAPET4 6/25/2018 BULLETIN #14
HJFPAPBPCPDP1P298.8L10"CONCRETE SIDEWALK,REFER TO SITE PLAN ANDCIVIL DRAWINGS FORMORE INFORMATION.DECORATIVE PAVING - SEELANDSCAPE DWGSPORTE COCHERELINE OF GLASS CANOPY ABOVEA500310'-0"16'-0"10'-0"5'-10"5'-11"1'-11"6"10"36'-0"8.9G98 3/4"1'-3 1/4"1'-2"2'-11"7'-1"3A402OUTLINE OF CONTINUOUS VERTICAL EXTERIOR GRADE TOWERACCENT LIGHT. LIGHT IS TO EXTEND FROM FIRST FLOOR UP TOEC-4 BAND AT TOWER. COORDINATE WITH PLANS, SECTIONS,ELEVATIONS, AND ELECTRICAL FOR MORE INFORMATION.SHADED REGION IS THE INTENT FOR THE LIGHT TO ILLUMINATETHE IN-SET METAL PANEL EC-6.JFPAPBPCPDP1P21A3001A30098.836'-0"14'-5 3/8"7'-2"7'-3 3/8"HORIZONTALTRANSLUCENT GLASSSKYLIGHT SYSTEMROOF BELOWROOF BELOWRDODRDODSLOPE @ 1/4" /FT. MIN. -TYP.HORIZONTALTRANSLUCENT GLASSSKYLIGHT SYSTEM8.9G9PBP1P2INSULATED METALPANEL SYSTEMFLUID APPLIED AIR &MOISTURE BARRIERINSULATED METALPANEL SYSTEMSTEEL COLUMN - SEESTRUCT. DWGS1/2" EXTERIOR GRADE FRTWOSB SHEATHINGALUM. PANEL CLIPATTACHED TO BLOCKINGCONCRETE SLAB BELOW,COLOR/FINISH TO CONTRAST WITHADJACENT STAMPED CONRETESIDEWALK - REFER TOARCHITECTURAL SITE PLAN ANDCIVIL DRAWINGS1'-10"1'-6"1'-10"4'-4"1'-6"8FT LONG RECESSED LINEARLIGHT, CENTERED ON METALPANEL - REFER TO EXTERIORELEVATIONS AND ELECTRICALDRAWINGS(2) RECESSED UPLIGHTS 'OD6'PER COLUMN PAD - REFER TOELECTRICAL DRAWINGS FORMORE INFORMATION.8"REVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED PLANS - PORTE COCHEREA500CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607423 OF 4815815JUNE 24, 2016 1/4" = 1'-0"A5001PORTE COCHERE PLAN 1/4" = 1'-0"A5002PORTE COCHERE ROOF PLAN 1" = 1'-0"A5003PORTE COCHERE COLUMN ENCLOSURES
EEJJ557GG6FFPAPBPCPD006HANGOUT001VESTIBULE002CART004WELCOME DESK003WELCOME LOBBY005MARKET010COFFEE HOUSEPUB007ELEVATOR LOBBY029WORK AREA031OFFICE013KITCHEN011PREFUNCTION014``5 1/2"12'-8 5/8"5 1/2"12'-8 1/2"5 1/2"11'-11 3/4"5 1/2"13'-5 1/4"5 1/2"27'-1 1/2"GAS FIREPLACE9'-0"12'-0"3'-0 5/8"5 1/2"4'-11 1/4"16'-6 3/8"034DOS OFFICE033IT ROOM032OFFICE12'-1 5/8"15'-2"13'-7"5 1/2"9'-2 1/8"15'-0 3/8"LOW WALL - SEE IDDWGBUFFETMILLWORK - SEEID DWGBAR MILLWORK -SEE ID DWGADA BARCOUNTER - SEEID DWG13'-3 5/8"11'-5 3/4"6"5'-1 1/4"6"9'-0 3/4"5 1/2"10'-5 3/4"5 1/2"9'-5 3/4"13'-2 1/8"6"20'-0"5 1/2"10'-5 3/4"12'-8 5/8"5 1/2"11'-1 1/4"5 1/2"4'-3 5/8"3'-0 1/2"12'-0 3/4"MILLWORK - SEEID DWG7.27.2K.87.57.58.598.88.8L.6L.68MMLK.21'-0 7/8"9 1/2"5 1/2"7'-11 1/4"5 1/2"4'-6 5/8"7'-6 5/8"5 1/2"4'-2 1/4"5 1/2"4'-8 5/8"1'-10"5 1/2"7 5/8"7'-4 3/4"7 5/8"3 3/8"7'-7 1/4"6 5/8"5 1/2"25'-9 7/8"4'-4 3/4"17'-7 5/8"16'-0"7'-11"17'-8 3/4"3'-2 5/8"12'-9 3/4"3'-2 5/8"A6501ELEV. #1ELEV. #219'-3"ALIGNED0G10 HR0G10 HR6'-1"6'-11 5/8"6'-1"4A4002A6512'-3 5/8"1'-9 1/2"3'-2 1/4"5'-0"5 1/2"5'-8 5/8"5 1/2"15'-1 1/4"5 1/2"4'-2 1/4"5 1/2"6'-6 5/8"5 1/2"7'-8"5'-5"1'-3"1'-3"5'-5"1'-0"11'-11 1/2"4'-0 1/2"2'-10"3'-0 1/2"1'-11 1/2"1'-3 1/2"1'-8"4'-7 1/2"5'-4"3'-0 1/2"2'-6"0A10 HR0A10 HR1A11 HR1A11 HR0G10 HR0A10 HR1L11 HR0G10 HR1L11 HR0G0 HR0G0 HR1A11 HR0G10 HR1A11 HR0G10 HR0A10 HR1A11 HR0A10 HR18'-10"20'-0 3/8"FRONT DESK MILLWORK- SEE ID DWGMILLWORK - SEE ID DWG5 SEGMENT WALL(3'-4") NICHE' -SEE ID DWG1 5 '-7 3 /8 "5 1/2"8'-1 3/4"5 1/2"6'-3 3/8"7 3/4"8'-8"3 3/8"7'-7 1/4"COUNTERTOP@ 34" A.F.F.029A031031033004002001013A009A035151A2'-10 5/8"5 1/2"4'-5 3/4"5 1/2"4'-0 1/2"5 1/2"2'-8"5 1/2"1'-7 1/2"5 1/2"8'-11 3/4"6"5 1/2"1'-2 3/4"1'-1"5'-9"4'-4 3/4"2'-0 7/8"0G10 HR1'-5"3'-0"MARKET MILLWORK -SEE ID DWGDISPLAY CASE:REFRIGERATED -SEE FS DWGDISPLAY CASE:FREEZER - SEE FSDWGFOR FOOD SERVICEEQUIP. SEE K DWGS.FOR BAR EQUIP.SEE K DWGS.5"1'-4 3/4"8'-2 1/4"A510145°0A10 HR1A11 HR0A10 HR1L11 HR0A10 HR0A10 HR0A10 HR0A10 HR0A10 HR0A10 HR1X1 HR1X1 HR1A11 HR0G10 HR0G10 HR1L11 HR0A10 HR1L11 HR0A10 HR0A10 HR0G10 HR1L11 HR0G10 HR0G10 HR0G10 HR1X1 HR0A10 HR8.98.9D.5D.54.54.5A5102A5104A5103A5106A5108A51010A51011A5107A5105A5109A51011Sim/Mirr.19'-0"3 1/2"5'-11"2'-0 1/2"1'-0 1/4"EQ(SEE WINDOW ELEVATIONS)12'-0" ROUGH OPENINGEQ.12'-2 1/2"A51012A5104SimA51013NG9G98.71A11 HR0A10 HR7'-2"TYPICAL ADA CLEARANCE(S)SHOWN FOR REFERENCE,REFER TO G002 FOR MOREINFORMATION.0100111X1 HR1X1 HRINDICATES DOOR TYPE - REFER TO SHEET A900FOR DOOR SCHEDULE & DOOR/FRAMEMATERIALS & ELEVATIONSTYPICAL SECTION AND DETAIL FLAGS:REFERS TO SECTION OR ELEVATION NUMBERREFERS TO DRAWING SHEET NUMBERKEY NOTEINDICATES WALL CONSTRUCTION TYPE & HEIGHT,REFER TO SHEET G004 FOR DETAILED ASSEMBLYDESCRIPTIONSINDICATES ROOM NAME AND NUMBER, REFERTO ID SHEETS FOR ROOM FINISHESROOMNAME###DATUM POINT, INDICATES ELEVATION OR SOILBORING LOCATION###INDICATES WINDOW TYPE, REFER TO SHEETA800 FOR WINDOW ELEVATIONS1tSYMBOL LEGEND#3BHEARING IMPAIRED SPEECH ROOM (9 TOTAL)REFER TO ELECTRICAL DRAWINGS0 4' 8' 10'1/4" 1'-0"6'0 4' 8' 10'1/4" 1'-0"6'REVISIONSNPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED PLAN - 1ST FLOORA501CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607424 OF 4815815JUNE 24, 2016 1/4" = 1'-0"A5011ENLARGED 1st FLOOR PLAN - PUBLICGENERAL NOTES - FLOOR PLAN1 ALL DIMENSIONS ARE TO FACE OF STUD WALL AND/OR MASONRY (UNLESSNOTED OTHERWISE).2 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONSAND/OR CONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH ACTUALCONDITIONS, CONTACT THE ARCHITECT FOR CLARIFICATION3 WALL THICKNESS INDICATED ON DRAWINGS SHALL BE CONSTANT FOR THEENTIRE LENGTH OF THE WALL (U.N.O.)4 PROVIDE BEHIND WALL REINFORCING AND BLOCKING AS REQUIRED FOR DOORSTOPS, ATTACHMENT OF MILLWORK, CASEWORK, TOILET ACCESSORIES, ETC.WOOD BLOCKING MUST BE FRTW.5 ALL OUTSIDE CORNERS THROUGHOUT THE INTERIOR SPACE TO HAVE METALCORNER BEADS6 REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION ON LOCATIONS ANDTYPES OF FINISH MATERIALS.7 SAW-CUT OR TOOLED CONTROL JOINTS AT INTERIOR EXPOSED CONCRETEFLOORS SHALL BE CAULKED WITH SEALANT AS REQ'D.8 REFER TO ENLARGED GUEST ROOM PLANS FOR DOOR TAGS & TYPES9 REFER TO CAMBRIA SUITES BY CHOICE STANDARDS MANUAL FOR ADDITIONALREQ'S FOR FIXTURES & EQUIPMENT, PASSENGER ELEVATORS, ELEVATORLOBBIES, CORRIDORS, STORAGE AREAS, MECHANICAL, ELECTRICAL, &EQUIPMENT ROOMS10 FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICES TOBE LOCATED PER LOCAL CODE. FIRE EXTINGUISHER LOCATIONS WITHIN THEPUBLIC SPACE SHALL BE CONTAINED WITHIN FULLY RECESSED CABINETS11 FIRE ALARM SYSTEM SHALL HAVE PERMANENTLY INSTALLED AUDIBLE & VISUALALARMS COMPLYING WITH NFPA 70, 72, & 101 & AS REQ'D BY LOCALAUTHORITIES. ALARMS MUST BE LOCATED IN PUBLIC & COMMON USE AREAS &GUEST ROOMS DESIGNATED AS "GUEST ROOMS WITH COMMUNICATIONFEATURES" AT A MINIMUM. WHERE EMPLOYEE AREAS HAVE AUDIBLE ALARMS,THE WIRING SHALL BE DESIGNED SO VISIBLE ALARMS CAN BE INTEGRATED INTOTHE SYSTEM, UNLESS GREATER STANDARDS ARE REQ'D BY LOCAL AUTHORITIES.REFER TO ELECTRICAL AND FIRE PROTECTION DRAWINGS.12 REFER TO FF&E PACKAGE WITHIN SPECIFICATIONS FOR FURNITURE, BUILT-INMILLWORK AND FINISH SPECIFICATIONS13 WALL MOUNTED EQUIP., FIXTURES, ETC. LOCATED BETWEEN 27" AND 80" A.F.F.SHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL PER ANSI ACCESSIBILITYSTANDARDS.14 GUESTROOM WALL TYPES: AT ALL WALL TILE LOCATIONS, CONTRACTOR TOPROVIDE 5/8" CEMENT BOARD IN LIEU OF GYPSUM BOARD. PRIOR TO INSTALLINGTILE, CONTRACTOR TO COVER WALL WITH RED GUARD, OR EQUAL. AT ALLOTHER WET WALL LOCATIONS THAT DO NOT HAVE TILE, CONTRACTOR TO USEMOISTURE RESISTANT GYPSUM BOARD (TYP).15 ALL FIRST FLOOR BEARING WALLS, INCLUDING EXTERIOR WALLS, ARE TO HAVE(2) 2x6 @ 16" O.C., TYPICAL.CONTRACTOR TO PROVIDE VERTICAL GYPSUMBOARD CONTROL JOINTS A MAXIMUM OF 30'-0" O.C.WHERE WALLS / PARTITIONS RUN UNINTERRUPTEDIN A STRAIGHT PLANE. FIELD LOCATE WITHARCHITECT PRIOR TO INSTALLING.GENERAL CONTRACTOR SHALL INSTALL 7/16" FRTWPLYWOOD BLOCKING A TOTAL OF 48" IN WIDTH (3 STUDCAVITIES) CENTERED BEHIND THE TV SHOWN ON ANYINCLUDED PLANS OR INTERIOR ELEVATIONS FROM 48" AFFTO 98" AFF. ELECTRICAL CONTRACTOR SHALL PROVIDEOUTLET AND DATA CONNECTIONS AS REQUIRED PERELECTRICAL DRAWINGS. DO NOT INSTALL THE ITEMSBEHIND THE TV UNTIL THE MOUNTING BRACKET IS SUPPLIEDBY THE GENERAL CONTRACTOR AND/OR OWNER.TV BLOCKING NOTE:NOTE:COLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PERPLANS, SECTIONS AND DETAILS. UNDER NOCIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFTEXPOSED UNLESS APPROVED BY CHOICE AND OWNER.STEEL FIRE PROOFING NOTE:
REF.EEJJ4321GG2.51A3002.8L.8L.8L.6MMK.2K.2012MEETING ROOM024LAUNDRY OFFICE026LINEN STOR.025LAUNDRY027LINEN CHUTE028ELEC.153STAIR B023MECH. RM020BEV. STOR.022ENG. OFFICE017BREAK RM018LOCKERS019EMP. TLT015FUNCTION STOR.013KITCHEN014``016BOH CORRIDOR011PREFUNCTIONA503A50319A50318161517DRYERDRYERDRYERTRENCH DRAINWASHERWASHER12'-3 1/4"5 1/2"10'-2 1/2"5 1/2"6'-1 1/4"5 1/2"8'-7"5 1/2"26'-7 1/4"3'-2"8'-0 1/2"5 1/2"30'-1 1/2"5 1/2"8'-5 1/2"5 1/2"20'-3 1/8"5 1/2"5'-1 7/8"0A10 HR2D12 HR1A11 HR1A11 HR1A11 HR1A11 HR1A11 HR1A11 HR0A10 HR1A11 HR1L11 HR1L11 HR1A11 HR1A11 HR1A11 HR0A10 HR1A11 HR0A10 HR0L10 HR0A10 HR013B1A11 HR016A01512'-1 5/8"15'-2"13'-7"5 1/2"9'-2 1/8"15'-0 3/8"5 1/2"6'-6 5/8"5 1/2"6'-5 3/8"5 1/2"9'-7 3/4"5 1/2"8'-2 1/4"5 1/2"7'-1 5/8"5 1/2"6'-6 3/8"5 1/2"5'-8 3/4"5 1/2"12'-11"8'-8 1/4"4'-8"1'-2"5 1/2"23'-11 3/4"23'-11 1/2"5 1/2"6'-1 3/4"5 1/2"6'-2 1/4"5 1/2"10'-11 1/2"23'-11 3/4"23'-11 1/2"5 1/2"6'-1 3/4"5 1/2"17'-1 1/4"8'-1 1/4"5 1/2"8'-9 7/8"5 1/2"8'-0 1/2"5 1/2"012E012D025A016C026017019020022023A028025B153A153B023B016B12'-9 1/4"5 1/2"10'-0 7/8"6'-2 3/8"5 1/2"11'-1 1/8"EYEWASHSTATIONLINEN CHUTEMETALLOCKERS12"x18"(2 TIERS)7'-0" OPNG3'-6"3'-3 3/4"5 1/2"7'-6"5 1/2"10'-3 3/4"5'-0" TALL WALLMILLWORK & COUNTERTOP - SEE ID DRAWINGS2'-6"1A4025 1/2"7'-1 1/8"5 1/2"H.8H.8H.2H.2D.7D.72.63.54.55 1/2"4"3'-4" R.O.13'-4 1/2"14'-0" ROUGH OPENING8'-0 1/4"5 1/2"012C13'-2"13'-2"4'-6"4'-5"4'-3"13'-2"13'-2"13'-2"2 1/2"A5111A5112A5113A51147'-0"011012B012A012FEQ15'-2"EQ.0A10 HR1A11 HR024INDICATES DOOR TYPE - REFER TO SHEET A900FOR DOOR SCHEDULE & DOOR/FRAMEMATERIALS & ELEVATIONSTYPICAL SECTION AND DETAIL FLAGS:REFERS TO SECTION OR ELEVATION NUMBERREFERS TO DRAWING SHEET NUMBERKEY NOTEINDICATES WALL CONSTRUCTION TYPE & HEIGHT,REFER TO SHEET G004 FOR DETAILED ASSEMBLYDESCRIPTIONSINDICATES ROOM NAME AND NUMBER, REFERTO ID SHEETS FOR ROOM FINISHESROOM NAME###DATUM POINT, INDICATES ELEVATION OR SOILBORING LOCATION###INDICATES WINDOW TYPE, REFER TO SHEETA800 FOR WINDOW ELEVATIONS1tSYMBOL LEGEND#3BHEARING IMPAIRED SPEECH ROOM (9 TOTAL)REFER TO ELECTRICAL DRAWINGS0 4' 8' 10'1/4" 1'-0"6'0 4' 8' 10'1/4" 1'-0"6'REVISIONSNPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED MEETING ROOM & BOH PLANSA502CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607425 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A5021ENLARGED 1ST FLOOR PLAN - MEETING RMS & BACK OF HOUSEGENERAL NOTES - FLOOR PLAN1 ALL DIMENSIONS ARE TO FACE OF STUD WALL AND/OR MASONRY (UNLESSNOTED OTHERWISE).2 VERIFY ALL DIMENSIONED CONDITIONS IN THE FIELD. WHEN DIMENSIONSAND/OR CONDITIONS AS INDICATED ON THE DRAWINGS CONFLICT WITH ACTUALCONDITIONS, CONTACT THE ARCHITECT FOR CLARIFICATION3 WALL THICKNESS INDICATED ON DRAWINGS SHALL BE CONSTANT FOR THEENTIRE LENGTH OF THE WALL (U.N.O.)4 PROVIDE BEHIND WALL REINFORCING AND BLOCKING AS REQUIRED FOR DOORSTOPS, ATTACHMENT OF MILLWORK, CASEWORK, TOILET ACCESSORIES, ETC.WOOD BLOCKING MUST BE FRTW.5 ALL OUTSIDE CORNERS THROUGHOUT THE INTERIOR SPACE TO HAVE METALCORNER BEADS6 REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION ON LOCATIONS ANDTYPES OF FINISH MATERIALS.7 SAW-CUT OR TOOLED CONTROL JOINTS AT INTERIOR EXPOSED CONCRETEFLOORS SHALL BE CAULKED WITH SEALANT AS REQ'D.8 REFER TO ENLARGED GUEST ROOM PLANS FOR DOOR TAGS & TYPES9 REFER TO CAMBRIA SUITES BY CHOICE STANDARDS MANUAL FOR ADDITIONALREQ'S FOR FIXTURES & EQUIPMENT, PASSENGER ELEVATORS, ELEVATORLOBBIES, CORRIDORS, STORAGE AREAS, MECHANICAL, ELECTRICAL, &EQUIPMENT ROOMS10 FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICES TOBE LOCATED PER LOCAL CODE. FIRE EXTINGUISHER LOCATIONS WITHIN THEPUBLIC SPACE SHALL BE CONTAINED WITHIN FULLY RECESSED CABINETS11 FIRE ALARM SYSTEM SHALL HAVE PERMANENTLY INSTALLED AUDIBLE & VISUALALARMS COMPLYING WITH NFPA 70, 72, & 101 & AS REQ'D BY LOCALAUTHORITIES. ALARMS MUST BE LOCATED IN PUBLIC & COMMON USE AREAS &GUEST ROOMS DESIGNATED AS "GUEST ROOMS WITH COMMUNICATIONFEATURES" AT A MINIMUM. WHERE EMPLOYEE AREAS HAVE AUDIBLE ALARMS,THE WIRING SHALL BE DESIGNED SO VISIBLE ALARMS CAN BE INTEGRATED INTOTHE SYSTEM, UNLESS GREATER STANDARDS ARE REQ'D BY LOCAL AUTHORITIES.REFER TO ELECTRICAL AND FIRE PROTECTION DRAWINGS.12 REFER TO FF&E PACKAGE WITHIN SPECIFICATIONS FOR FURNITURE, BUILT-INMILLWORK AND FINISH SPECIFICATIONS13 WALL MOUNTED EQUIP., FIXTURES, ETC. LOCATED BETWEEN 27" AND 80" A.F.F.SHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL PER ANSI ACCESSIBILITYSTANDARDS.14 GUESTROOM WALL TYPES: AT ALL WALL TILE LOCATIONS, CONTRACTOR TOPROVIDE 5/8" CEMENT BOARD IN LIEU OF GYPSUM BOARD. PRIOR TO INSTALLINGTILE, CONTRACTOR TO COVER WALL WITH RED GUARD, OR EQUAL. AT ALLOTHER WET WALL LOCATIONS THAT DO NOT HAVE TILE, CONTRACTOR TO USEMOISTURE RESISTANT GYPSUM BOARD (TYP).15 ALL FIRST FLOOR BEARING WALLS, INCLUDING EXTERIOR WALLS, ARE TO HAVE(2) 2x6 @ 16" O.C., TYPICAL.CONTRACTOR TO PROVIDE VERTICAL GYPSUMBOARD CONTROL JOINTS A MAXIMUM OF 30'-0" O.C.WHERE WALLS / PARTITIONS RUN UNINTERRUPTEDIN A STRAIGHT PLANE. FIELD LOCATE WITHARCHITECT PRIOR TO INSTALLING.GENERAL CONTRACTOR SHALL INSTALL 7/16" FRTWPLYWOOD BLOCKING A TOTAL OF 48" IN WIDTH (3 STUDCAVITIES) CENTERED BEHIND THE TV SHOWN ON ANYINCLUDED PLANS OR INTERIOR ELEVATIONS FROM 48" AFFTO 98" AFF. ELECTRICAL CONTRACTOR SHALL PROVIDEOUTLET AND DATA CONNECTIONS AS REQUIRED PERELECTRICAL DRAWINGS. DO NOT INSTALL THE ITEMSBEHIND THE TV UNTIL THE MOUNTING BRACKET IS SUPPLIEDBY THE GENERAL CONTRACTOR AND/OR OWNER.TV BLOCKING NOTE:NOTE:COLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PERPLANS, SECTIONS AND DETAILS. UNDER NOCIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFTEXPOSED UNLESS APPROVED BY CHOICE AND OWNER.STEEL FIRE PROOFING NOTE:2 8/9/2016 ADD. #22
D W
DE
5
7
6
2
A300
2
A300
7.2
7.5
4
A400
2
A651
2E
2 HR
1L1
1 HR
0A1
0 HR
0G1
0 HR
0A1
0 HR
0A1
0 HR
0G1
0 HR
0A1
0 HR
0G1
0 HR
0G1
0 HR
1L1
1 HR
2D1
2 HR
0G1
0 HR
0L1
0 HR2D1
2 HR
0G1
0 HR
0G1
0 HR
009
MEN TLT
008
WOMEN TLT
036
GUEST LAUNDRY
035
ELEV. EQ. RM
0G1
0 HR
039
FITNESS CENTER
010
COFFEE HOUSE
PUB
151
CORRIDOR
G42
G36
A503
2
3 5
4
1
G42
G18
G36
2
3
55
111
1
G18
7
3
55
5'-7 7/8"
2 1/2"
2'-7 1/8"3'-1 1/8"
1'-3 3/4"
6'-1 1/2"1'-10"
5 1/2"
4'-7 1/4"9'-11 1/8"1'-8 1/2"2'-5"6"5'-1 7/8"5 1/2"7'-2 1/8"2'-7"4'-6"1'-4 3/4"8'-9 1/4"5 1/2"4'-7 1/4"5 1/2"
16'-0 7/8"
5 1/2"
3 7/8"6'-7 3/8"2'-5"7 3/4"
5 1/2"
2'-11 7/8"
2 1/2"
2'-11 1/4"
2 1/2"
2'-11 1/4"
2 1/2"
6'-7"
5 1/2"
10'-9 1/4"5 1/2"8'-1 5/8"6'-9"
2 3/4"5'-10 1/8"5'-0"3 3/4"2
222
4
32" HIGH
FOLDING
COUNTER
HI-LO ELEC.
WATER
COOLER-SEE
PLUMB. DWG
A503
6
9
8
7
0A2
0 HR
0A2
0 HR
8
8
9'-8 5/8"5'-0 5/8"2 1/2"5'-4 1/2"0A2
0 HR
D.5
6.3 1'-5"WALL TILE -
SEE ID
DWG
MAX.3'-2"CONC. RAMP SINK
COUNTER -SEE ID
DWG FOR COLOR
5
5
32
1
G18
G42 G36
MIRROR -
SEE ID DWG
5
WALL
SCONCE -SEE
ELEC. DWG
1'-0"6'-8"G36
1
G42G18
RECESSED
LIGHT
FIXTURE -
SEE ELEC.
DWG.
1'-6"
WALL SCONCE -SEE
ELEC. DWG
MIRROR -
SEE ID
DWG
55
7
CONC. RAMP SINK
COUNTER -SEE ID
DWG FOR COLOR4'-8"2'-10"5
4
EQEQ
WALL
SCONCE -SEE
ELEC. DWG
1'-0 7/8"
2
122
1 1
2
G36
G18
G42
1
1'-4"
3
8
88 2'-6"2'-6"1'-4"
RECESSED
LIGHT
FIXTURE -SEE
ELEC. DWG.
ABCD
5
A.3B.5
7.2
1
A202
037
CORRIDOR
038
STORAGE
040
INDOOR
SWIMMING POOL
039
FITNESS CENTER
7'-6 1/2"5 1/2"31'-0 1/2"
5 1/2"
6'-1 1/4"
5 1/2"
6'-1 3/4"1'-6"3'-0"3'-6 1/2"5'-7"5'-4 3/4"9'-8"10 3/4"7'-6 1/2"5 1/2"31'-0 1/2"5 1/2"8"10'-8"1'-4 1/2"5 1/2"
ICE
MACHINE
A503 14
11
12
13
1A1
1 HR
1C
1 HR
1L1
1 HR
1A1
1 HR
1L1
1 HR
1A1
1 HR
1A1
1 HR
0G1
0 HR
POOL LADDERACCESSIBLE
SWIMMER
LIFT
POOL DEPTH (FEET &
METERS) WITH NO DIVING
GRAPHS TILES -TYP.
SS
HANDRAIL
PERIMETER DECK
DRAIN
042
POOL MECH.
ROOM
041
POOL EQPM RM
6'-6 1/4"18'-0"6'-9"7'-9 1/2"4 1/2"5'-0"6'-6 1/4"30'-0"10'-5 3/4"15'-6"9'-0"5'-6"10'-5 3/4"0A1
0 HR
1A1
1 HR
041
042
040
A
039
IW4
IW3
IW2
038
STEPS
040
C
040
BW11
W10
2'-0"
POOL
LADDER
-3'-5"
0A1
0 HR
1A1
1 HR
1A1
1 HR
037
3'-1"1
A301
1
A301
2
A301
2
A301
043
MEN'S1'-7"14'-0"C.5 A.5
4.3
6.2
6.3
B.3
1
A403
13'-2"13'-2"13'-2"5'-2"8'-0"13'-2"5'-2"8'-0"
1A1
1 HR
1A1
1 HR
0A1
0 HR
DASHED LINE INDICATES CONTINUOUS 10 MIL VAPOR
BARRIER DIRECTLY BEHIND INTERIOR GYPSUM BOARD.
CONTRACTOR TO EXTEND THE VAPOR BARRIER UP TO
CEILING. ENTIRE CEILING WITHIN DASHED AREA IS ALSO
TO RECEIVE THE 10 MIL VAPOR BARRIER. REFER TO
RCP AND SECTIONS FOR MORE INFORMATION.
5 1/2"5'-4"20'-4"
12" STAINED CONCRETE
POOL COPING AND TILE
WALL BORDER AT POOL
PERIMETER, TYP.
POOL CEILING FINISH NOTE:
POOL CEILING IS TO HAVE A
LEVEL 5 FINISH WITH EPOXY
PAINT -COORDINATE WITH
INTERIOR DESIGN DRAWINGS.
044
043
044
WOMEN'S
1'-6"
5 1/2"2'-5 1/4"5'-1 1/4"5 1/2"14'-1 1/4"5 1/2"11'-7 1/4"5 1/2"7'-4 1/4"3 1/2"2'-4 1/2"3 1/2"10'-0 7/8"5 1/2"5 1/2"7'-6 1/2"5 1/2"6'-6 1/4"10'-0"8'-0"7'-2 1/4"
0A
0 HR
0G
0 HR
1'-4"1'-6"1'-4"6
6
CART, FOR
REFERENCE
ONLY
1'-0"
5'-1 1/4"
1'-5 1/4"2'-8"1'-8"0G
0 HR
1X
1 HR
0A1
0 HR
FULL-HEIGHT
TILE, SEE ID
PREFORMED
INSULATED
PIPE COVER
MIRROR -SEE
ID DWG
SEE ID5'-0" TILE044
1'-4"SEE ID5'-0" TILE1'-6"
3'-0" TILE
SEE ID5'-0" TILEFULL-HEIGHT TILE1'-8"
1'-7 1/8"
1'-9"1'-7"1'-6"
PREFORMED
INSULATED
PIPE COVER
MIRROR -SEE
ID DWG
6
2
G18
G36
G42
1
1
G42
G18
G36
9
1'-2"
2'-6"3'-0"3'-0"7'-0"1'-3"2'-10"1'-8"2'-6"REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED PLAN & ELEVATIONSA503CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607426 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A503
1 ENLARGED PLAN - PUBLIC TOILETS
1/4" = 1'-0"A503
2 MENS TOILET ELEVATION
1/4" = 1'-0"A503
3
MENS TOILET
ELEVATION
1/4" = 1'-0"A503
4 MENS TOILET ELEVATION
1/4" = 1'-0"A503
5
MENS TOILET
ELEVATION
1/4" = 1'-0"A503
6 WOMENS TOILET ELEVATION
1/4" = 1'-0"A503
7
WOMENS TOILET
ELEVATION
1/4" = 1'-0"A503
8 WOMENS TOILET ELEVATION
1/4" = 1'-0"A503
9
WOMENS TOILET
ELEVATION
1/4" = 1'-0"A503
10 ENLARGED PLAN - POOL TOILET
1/4" = 1'-0"A503
11
POOL TOILET
ELEVATION
1/4" = 1'-0"A503
12
POOL TOILET
ELEVATION
1/4" = 1'-0"A503
13
POOL TOILET
ELEVATION
1/4" = 1'-0"A503
14
POOL TOILET
ELEVATION
1/4" = 1'-0"A503
15
EMP. TOILET
ELEVATION
1/4" = 1'-0"A503
16
EMP. TOILET
ELEVATION
1/4" = 1'-0"A503
17
EMP. TOILET
ELEVATION
1/4" = 1'-0"A503
18
LOCKER RM
ELEVATION
1/4" = 1'-0"A503
19
BREAK RM
ELEVATION
1. PROVIDE METRIC AND FEET AND INCHES AT ALL DEPTH LOCATIONS (VERTICALLY & HORIZONTALLY) VERIFY
POOL REQUIREMENTS WITH LOCAL HEALTH DEPARTMENT.
2. POOL SIZE MAY VARY. THE CONTRACTOR SHALL CONTRACT WITH A POOL CONTRACTOR WHO SHALL PROVIDE
A DESIGN/BUILD POOL. THESE DRAWINGS AND SPECIFICATIONS ARE GENERAL CRITERIA ONLY.
3. GENERAL CONTRACTOR SHALL VERIFY THE POOL AND ADA LIFT GROUNDING AND BONDING REQUIREMENTS
WITH NATIONAL, STATE, AND LOCAL CODES.
4. GENERAL CONTRACTOR TO VERIFY POOL SIZE IN RELATION TO QUANTITY OF ADA POOL LIFTS REQUIRED.
5. POOL DECK IS TO SLOPE A MINIMUM OF 1/4" PER FOOT TOWARDS DECK DRAIN, TYPICAL.
POOL NOTES:
1. GENERAL CONTRACTOR SHALL SECURE A SWIMMING POOL SUBCONTRACTOR THAT WILL BE RESONSIBLE
FOR A SWIMMING POOL W/ A 3' TO 5' DEPTH AND SHALL BE A PUBLIC CONCRETE POOL COMPLETE WITH
DRAINAGE AND FILTRATION SYSTEM, LADDER, ALL MECHANICAL, PLUMBING AND ELECTRICAL WORK
INCLUDING UNDERWATER LIGHTS, HEATER, RESCUE DEVICES AND MOISTURE CONTROL. POOL DEPTH SHALL
BE MARKED ON POOL DECK EDGE AT APPROPRIATE INTERVALS AND DEPTH CHANGE.
2. EXCAVATION, PERMITS, STATE OF CONNECTICUT HEALTH DEPARTMENT SUBMITTALS, MARKER SAFETY SIGNS,
AND ALL THAT IS REQUIRED BY STATE AND LOCAL CODES FOR SWIMMING POOL
CONSTRUCTION/INSTALLATION SHALL BE THE SOLE RESPONSIBILITY OF THE SWIMMING POOL CONTRACTOR
(INCLUDING BUT NOT LIMITED TOO, POOL EQUIPMENT, CONDUIT LINES, DRAINS, ETC). POOL COMPANY SHALL
SUBMIT ALL REQUIRED DRAWINGS TO ALL REQUIRED AUTHORITIES FOR APPROVAL PRIOR TO INSTALLATION.
3. POOL DECK MUST BE DECORATIVELY SURFACED WITH A FINISH THAT PROVIDES A MINIMUM COEFFICIENT OF
FRICTION, WET & DRY, OF 0.6 - OWNER AND CHOICE HOTELS ARE TO APPROVE.
4. BEFORE ANY SUBMITTALS TO REQUIRED AUTHORITIES, RECEIVE DESIGN APPROVAL FROM OWNER. THIS
INCLUDES THE TYPE OF POOL TREATMENT SYSTEM (LIQUID CHLORINE, TABLET CHLORINE, SALT, ETC.)
GENERAL CONTRACTOR NOTES:
NOTE:
REFER TO SHEET G003 FOR
RESTROOM ACCESSORY AND GRAB
BAR MOUNTING HEIGHTS, TYP.
Public Toilet Accessory Schedule
Type Mark Description Manufacturer Model
1 Surface Mounted Multi-Roll Toilet Tissue Dispenser Bobrick B-4288
2 Recessed Toilet Seat Cover Dispenser Bobrick B-3013
3 Recessed Paper Towel Dispenser & Waste Receptacle Bobrick B-43944
4 Recessed Baby Changing Station Koala KB110-SSRE
5 Sensor-Operated Soap Dispenser - Lavatory Mounted Bobrick B-8263.18
6 Soap Dispenser Bradley Corporation 6437
7 Semi-Recessed Napkin/Tampon Vendor Bobrick B-4706
8 Bobrick B-4353 Contura Series Sanitary Napkin Disposal Bobrick Washroom
Equipment, Inc.
B-4353
9 Recessed Stainless Steel Paper Towel Dispense Bobrick B-359
10 Surface Mounted Double Robe Hook Bobrick B-6727
D Shower Curtain Rod Bradley Corporation 9530
G18 18" Grab Bar WingIts WGB5IESN18
G36 36" Grab Bar WingIts WGB5IESN36
G42 42" Grab Bar WingIts WGB5IESN42
COLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PER
PLANS, SECTIONS AND DETAILS. UNDER NO
CIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFT
EXPOSED UNLESS APPROVED BY CHOICE AND OWNER.
STEEL FIRE PROOFING NOTE:
6
6
6 11/05/2018 BULLETIN #3
EJ55447G66P17.2K.87.58.598.88.8L.68MMK.22'-6"1'-10 1/2"5 5/8"11 1/4"1'-10 1/2"5 5/8"1'-5"3'-6"6"9"9"10"1'-0"4'-6"3'-6"4'-6"2'-5"1'-1 7/8"3'-8 3/8"5'-10"5'-10"2'-6 1/2"4'-3"4'-5"4'-3"4'-5"4'-3"2'-5"1'-1 7/8"4'-6"3'-6"2'-10"2'-10"5'-8"3'-5 3/4"3'-5 3/4"3'-3 7/8"13'-4"1'-4"1'-2"2'-0"1'-0"7"1'-1"1'-0"8"11"9 '-0 "10'-6"13'-4"MILLWORK CLGELEMENT - SEEID DWGSMILLWORK CLGELEMENT - SEEID DWGS5°15°15°10°4'-0"4'-0"2'-5 7/8"7'-0"2'-6 1/8"7'-2"16'-2 3/8"10°13°12°.13°6°6°MILLWORK CLGELEMENT - SEEID DWGS2'-3 1/4"9'-1 1/4"9'-11 3/8"2'-3 7/8"1'-8 1/8"4'-0"4'-0"4'-0"3'-4 7/8"1'-9"4'-6"3'-0"3'-0"4'-6"2'-0"4'-6"4'-6"2'-8"1'-10"4'-6"4'-6"3'-9"3'-9"2'-7 1/2"7'-0"7'-0"2'-7 1/2"1'-10 7/8"3'-0"1'-6"1'-6"3'-0"1'-10 7/8"3'-9 5/8"7'-6"2'-6"2'-6"17'-8"5°10°
1 0 °5°10°10°1'-6"1'-6"1'-2"9'-2 1/2"3'-6"11'-5 1/2"9'-0"2'-0 3/4"3'-1"4'-5"2'-10"4'-8"3'-4 3/8"4'-5"5'-0 1/2"4'-9 1/2"12'-0"4'-3"4'-4 5/8"3'-9"4'-1 1/4"42'-0"5'-7 3/4"1'-7 3/4"2'-8"1'-2"1'-2"1'-2"1'-2"7"7"1'-2"1'-2"1'-2"1'-2"4'-6"4'-6"4'-6"4'-6"4'-6"4'-6"4'-6"3'-0 3/4"3'-0"1'-6"1'-6"3'-0"9'-0"9'-0"9'-0"6'-11 5/8"FACE MOUNTEDCOVE LIGHT5'-11 1/4"5'-11 1/4"2'-0"GWB9'-6"GWB9'-0"GWB10'-0"GWB11'-0"GWB9'-0"GWB8'-0"GWB9'-0"GWB9'-0"GWB10'-0"GWB10'-0"GWB10'-0"GWB10'-0"GWB10'-6"GWB8'-0"ACT9'-0"ACT9'-0"ACT8'-6"010COFFEE HOUSEPUBELEVATORLOBBY007003WELCOME LOBBY001VESTIBULE002CART031OFFICE029WORK AREA005MARKET011PREFUNCTION013KITCHEN016BOH CORRIDOR2A4103'-1"10'-4"4'-8"3'-0"4'-6"4'-6"3'-0"7'-9 3/8"5'-0 1/2"4'-9 1/2"16'-3"4'-4 5/8"3'-9"17'-6"9°9°2'-9 1/4"2'-9"2'-9 1/4"2'-9"3'-0 1/4"2'-9 1/2"9'-0"9'-0"9'-0"GWB9'-4"GWB9'-6"8.98.94.54.5N8.78.7GWB10'-0"13'-6 3/8"OUTLINE OF CONTINUOUS VERTICAL EXTERIORGRADE TOWER ACCENT LIGHT. LIGHT IS TO EXTENDFROM FIRST FLOOR UP TO EC-4 BAND AT TOWER.COORDINATE WITH PLANS, SECTIONS, ELEVATIONS,AND ELECTRICAL FOR MORE INFORMATION.SHADED REGION IS THE INTENT FOR THE LIGHT TOILLUMINATE THE IN-SET METAL PANEL EC-6.0 4' 8' 10'1/4" 1'-0"6'0 4' 8' 10'1/4" 1'-0"6'REVISIONSNPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED 1ST FLR RCPA504CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607427 OF 4815815JUNE 24, 2016 1/4" = 1'-0"A5041ENLARGED 1ST FLOOR REFLECTED CLG PLANCOLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PERPLANS, SECTIONS AND DETAILS. UNDER NOCIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFTEXPOSED UNLESS APPROVED BY CHOICE AND OWNER.STEEL FIRE PROOFING NOTE:
JPC9LLIGHT FIXTURE TO EXTEND UP ENTIRE FACE OF WALL AND ILLUMINATE WALL (SHOWN GRAY) -REFER TO EXTERIOR ELEVATIONSR-21 KRAFT FACED BATT INSULATION, TYPSEALANT AND BACKER ROD4"5'-11"2'-1"1'-0"1'-2"7'-1"10"11 1/4"3'-0"11 1/4"7 1/4"6" ALUMINUM CURTAIN WALL SYSTEM, REFER TO GLAZING ELEVATIONS & DETALSINSULATED METAL PANEL OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGE.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGSTEEL COLUMN -REFER TO STRUCTURE FOR SIZING. PROVIDE 1-HOUR RATED INTUMESCENT PAINT0G0 HR1A11 HR0G0 HR(VERIFY)± 8"L.68MN5 1/2"4'-6 1/2"5 1/2"11 1/2"5 1/2"5 1/2"5'-0"5 1/2"1'-10 1/2"4 1/4"3'-0"1'-7 3/4"9 1/2"3 1/2"0G0 HR0G10 HRDASHED LINE INDICATES 2x6 STUD BELOW/ABOVE6" ALUMINUM CURTAIN WALL SYSTEM, REFER TO GLAZING ELEVATIONS & DETALSR-21 KRAFT FACED BATT INSULATION, TYPE.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHING6 1/2"SEALANT & BACKER ROD, TYP.0G10 HRSTEEL COLUMN -REFER TO STRUCTURE FOR SIZING. PROVIDE 1-HOUR RATED FIRE PROOFING, TYP.2'-0 1/4"2'-6 1/4"SEALANT & BACKER ROD, TYP.J75/8"5/8"2 1/2"PLANSEE2 1/2"5/8"5/8"SQUARESQUARENOTEREFER TO GA FILE CM1452 FOR COMPLETE 1-HOUR RATED ASSEMBLY DESCRIPTION9M6"8"4 1/4"6"8"NPROVIDE ASSEMBLY '6' TO ENCLOSE COLUMN -REFER TO INTERIOR DESIGN FOR FINISHES6" ALUMINUM CURTAIN WALL SYSTEM, REFER TO GLAZING ELEVATIONS & DETALS6"x6" CORNER MULLIONE50A10 HR1X1 HR1X1 HRMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHINGJ8.51A11 HR1A11 HRSTEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS PROVIDED WITH CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.POWERED SLIDING GLASS DOOR -REFER TO ELEVATIONS AND OVERALL PLANS FOR MORE INFORMATION.CENTER WALL(S) ON COLUMN LINE, UNLESS NOTED OTHERWISE.46K.8L1A11 HR1A11 HR0A10 HR0G10 HR1'-3 5/8"5 1/2"2'-7"5 1/2"4"5 1/2"STEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS PROVIDED WITH CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.PROVIDE SOLID BLOCKING AS REQUIRED, TYP.9"1'-0 1/4"ROOF DRAIN WITHIN BUILD-OUT - REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.7L.6MSTEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS WITHIN THE 1-HOUR RATED COLUMN ENCLOSURE AND IF NOT, PROVIDE THE CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.DOUBLE 2x FRAMING SHOWN FOR REFERENCE ONLY -REFER TO STRUCTURE FOR STUD SPACING AND QUANTITIY PER FLOOR.E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHINGSEALANT & BACKER ROD, TYP.0G0 HR0G10 HR0G20 HRPROVIDE 2x FURRING AND GYPSUM BOARD TO ALIGN WITH ADJACENT WALL -REFER TO WINDOW TYPES FOR MORE INFORMATION.3 1/2"5 1/8"11 1/2"5 1/2"1'-7 3/4"11 3/8"F8.71A11 HR1A11 HR0A10 HR1'-4 1/2"5 1/2"5 1/2"1'-2 1/4"PROVIDE BLOCKING AS REQUIRED, TYP.PROVIDE 6" SOUND BATT INSULATION.PROVIDE BLOCKING AS REQUIRED, TYP.F7.50G10 HR1L11 HRCOUNTERTOP -REFER TO INTERIOR DESIGN DRAWINGSPROVIDE CONTINUOUS 6" SOUND BATT AROUND THE OFFICE SPACE, REFER TO OVERALL PLANS FOR MORE INFORMATION.PROVIDE SOLID BLOCKING AT CORNER90°2 2 °18'-10" RADIUSSTEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS PROVIDED WITH CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.4G6STEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS PROVIDED WITH CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.5/8"1'-0 3/8"2'-1"5/8"7"5 1/2"5 1/2"5/8"16'-0" RADIUS0G10 HR0G10 HR0G10 HR0G10 HR4H8.88.98 3/4"G9E.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGSEALANT & BACKER ROD, TYP.STEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS PROVIDED WITH CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.4F8.88.96"5/8"5 1/2"1/2"5/8"5 1/2"MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHINGE.I.F.S. FINISH (SEE ELEVATIONS FOR COLOR) OVER PRIMER/ADHESIVE COATING OVER MESH APPLIED TO 3" RIGID INSULATION BOARD OVER PRIMER/ADHESIVE COATING OVER FLUID APPLIED AIR/MOISTURE BARRIER APPLIED TO 1/2" EXTERIOR GRADE OSB SHEATHINGSEALANT & BACKER ROD, TYP.REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333PLAN DETAILSA510CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607428 OF 4915815JUNE 24, 2016 1 1/2" = 1'-0"A5101PLAN DETAIL @ BUILDING UPLIGHT 1 1/2" = 1'-0"A5102COLUMN LINE M & 8 DETAIL 1 1/2" = 1'-0"A5104TYP COLUMN WRAP (1-HR) 1 1/2" = 1'-0"A5103CORNER CURTAIN WALL DETAIL 1 1/2" = 1'-0"A5105COLUMN LINE E & 5 DETAIL 1 1/2" = 1'-0"A5108COLUMN LINE J & 8.5 DETAIL 1 1/2" = 1'-0"A5107COLUMN LINE K.8 & 6 DETAIL 1 1/2" = 1'-0"A5106COLUMN LINE L.6 & 7 DETAIL 1 1/2" = 1'-0"A5109COLUMN LINE F & 8.5 DETAIL 1 1/2" = 1'-0"A51010COLUMN LINE F & 7.5 DETAIL 1 1/2" = 1'-0"A51011COLUMN LINE G & 6 DETAIL 1 1/2" = 1'-0"A51012COLUMN LINE H & 8.8 DETAIL 1 1/2" = 1'-0"A51013PLAN DETAIL @ REVEALCOLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PER PLANS, SECTIONS AND DETAILS. UNDER NO CIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFT EXPOSED UNLESS APPROVED BY CHOICE AND OWNER.STEEL FIRE PROOFING NOTE:4 6/25/2018 BULLETIN #14444
GF2.65 1/2"5'-8 3/8"5 1/2"3'-4"4'-0 1/2"(COORDINATE WITH SELECTED PARTITION COMPANY)5'-6" CLEAR - MODERNFOLD IS BASIS OF DESIGN(COORDINATE WITH SELECTED PARTITION COMPANY)3'-9" CLEAR - MODERNFOLD IS BASIS OF DESIGN1234567811"5'-4"11"1L11 HR1L11 HR1L11 HRSTEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS PROVIDED WITH CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.42L.6M2E2 HR0F0 HR0F0 HR0G20 HR3'-0"1"7 5/8"7/8"5/8"1'-1 1/4"MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHINGMANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER1X1 HR153STAIR B023MECH. RM1K.2153A1'-6 1/4"1"1/2"5 1/2"1'-3 1/2"7 5/8"0F0 HR5/8"7/8"7 5/8"7/8"5/8"ALIGN FACE OF METAL FURRING WITH FACE OF STUD.MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHING2E2 HR1X1 HRE4MANUFACTURED STONE VENEER ON MORTAR SETTING BED, ON MORTAR SCRATCH COAT, ON LATH, ON FLUID APPLIED AIR/MOISTURE BARRIER, ON 1/2" EXTERIOR GRADE OSB SHEATHINGSTEEL COLUMN -REFER TO STRUCTURE FOR SIZING. ENSURE COLUMN IS PROVIDED WITH CONTINUOUS 1-HOUR FIRE PROOFING, TYPICAL.1L11 HR1X1 HR1X1 HRREVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333PLAN DETAILSA511CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607429 OF 4915815JUNE 24, 2016 1 1/2" = 1'-0"A5111PLAN DETAIL @ FOLDING PARTITION 1 1/2" = 1'-0"A5112PLAN DETAIL @ STAIR CORNER 1 1/2" = 1'-0"A5113PLAN DETAIL @ STAIR CORNER 1 1/2" = 1'-0"A5114COLUMN LINE E & 4 DETAILCOLUMNS/BEAMS ARE TO BE FULLY ENCLOSED PER PLANS, SECTIONS AND DETAILS. UNDER NO CIRCUMSTANCES ARE THE BEAMS/COLUMNS TO BE LEFT EXPOSED UNLESS APPROVED BY CHOICE AND OWNER.STEEL FIRE PROOFING NOTE:4 6/25/2018 BULLETIN #14
UPDNUPDNUPDNUPUPDNDNUPDNA7.54'-7 3/4"7'-0"5'-0 1/2"12T @ 11"11'-11"7'-0 3/4"25'-3 1/2"152STAIR A0F0 HR0F0 HR2E2 HR2E2 HR152B152A5A6005'-5 1/4" CLR.5'-8 1/4"4'-8 1/4"7 5/8"21'-7 3/4"11'-8"MECHSHAFTA.5A7.54'-9 1/2"8T @ 11"7'-2 1/4"11'-8"5'-6 3/4"18'-1"252STAIR A2E2 HR0F0 HR2526'-8 1/4"7'-0"5A6004'-7 1/2"5'-6"A.5A7.54'-7 3/4"19'-0"25'-3 1/2"352STAIR A2E2 HR0F0 HR6'-8 1/4"7'-0"5A6004'-9 1/4"5'-4 1/4"352A.5A7.5452STAIR A6'-8 1/4"7'-0"4522E2 HR0F0 HR25'-3 1/2"5A60010'-1 1/2"A.5Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"7.59'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"9 R @ 6 11/16"5'-8 1/8"9 R @ 6 11/16"5'-1 1/4"9 R @ 6 11/16"5'-8 1/8"9 R @ 6 11/16"5'-1 1/4"12 R @ 6 3/4"7'-3 5/8"13 R @ 6 3/4"7'-10 3/8"452STAIR A352STAIR A252STAIR A152STAIR AMETAL HANDRAIL - TYP.SEE DETAILS THIS SHEETTruss Bearing45'-10 3/8"2-HOUR SHAFT LID ASSEMBLY,PER UL ASSEMBLY ON G0051'-0" MIN.CONTINUOUS BONDBEAM WITH (2) #5ATTACH PERIMETER (2) 11-1/4"LVL TO CMU WITH 1/2" DOUBLE(TOP & BOTTOM) EXPANSIONANCHORS BEARING 2-3/4"MINIMUM INTO CMU (GROUTEDSOLID). BOLTS ARE TO BE 16"O.C., STAGGERED.TYPICAL LANDING:1 1/4" GYPSUM CONCRETE FLOOR3/4" OSB SUBFLOOR2x12 FLOOR JOISTS @ 16" O.C.5/8" TYPE 'X' GYPSUM BOARDPROVIDE (1) CONTINUOUS BONDBEAM AT EACH LANDING w/ (1) #4.FULLY GROUT MIN (2) COURSESBELOW, TYP.3'-0"3'-0"(2) 11 1/4" PERIMETER LVL, TYP.A60011A60012A60013TYP.TYP.TYP.J21L.6L2E2 HR0F0 HR153B153A5'-5 1/8"9 3/4"5'-5 1/8"7 5/8"1 1/2"6'-6"12T @ 11"11'-0"11'-8"1'-6 1/4"1/4"1"36" PIPE RAILWALL MOUNTEDHAND RAIL153STAIR B028ELEC.027LINEN CHUTE1A11 HR2D12 HRBELOWLANDING8A651J21L.6LWALL MOUNTEDHAND RAIL2E2 HR0G20 HR0F0 HR1 1/2"10'-0 1/4"8T @ 11"7'-4"4'-7 3/4"1/4"253STAIR B250CORR.242LINEN CHUTE1A1 HR1C1 HR5'-10 1/2"1 1/2"2'-11 3/4"2'-10 3/4"2S2 HR24"Ø LINENCHUTE5 1/2"10A6002532421"11"H.80"8 1/4"4'-8 1/4"4'-1 1/2"8A651J21L.6L1 1/2"17'-4 1/4"4'-7 3/4"1'-6 1/4"11'-8"16'-5 1/4"5'-6 3/4"23'-7 3/4"353STAIR B340LINEN CHUTE350CORR.4'-6 1/2"5'-4 1/4"WALL MOUNTEDHAND RAILWALL MOUNTEDHAND RAIL24"Ø LINENCHUTE2E2 HR0F0 HR2S2 HR1A1 HR2'-11 3/4"2'-10 3/4"5 3/8"10A6003533401C1 HRH.80"8 1/4"4'-8 1/4"4'-1 1/2"8A651J21L.6L453STAIR B442LINEN CHUTE450CORR.1'-6 1/4"11'-8"1 1/2"4534421A1 HR1L11 HR2E2 HR0F0 HRWALL MOUNTEDHAND RAIL24"Ø LINENCHUTE2'-10 3/4"4 1/4"H.84 1/2"5'-4 3/4"8A651Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"JL.8L.6L453STAIR B353STAIR B253STAIR B153STAIR B028ELEC.250CORR.350CORR.450CORR.9 R @ 6 11/16"5'-8 1/8"9 R @ 6 11/16"5'-1 1/4"9 R @ 6 11/16"5'-8 1/8"9 R @ 6 11/16"5'-1 1/4"12 R @ 6 3/4"7'-10 3/8"13 R @ 6 3/4"7'-3 5/8"9'-1 5/8"10'-9 3/8"10'-9 3/8"15'-2"Truss Bearing45'-10 3/8"1'-0" MIN.1'-0" MIN.1'-0" MIN.1'-0" MIN.1'-0" MIN.1'-0"4'-0" MIN.A60012A60011A60013TYP.TYP.TYP.3'-0"A60012153ATYP.ATTACH PERIMETER (2) 11-1/4"LVL TO CMU WITH 1/2" DOUBLE(TOP & BOTTOM) EXPANSIONANCHORS BEARING 2-3/4"MINIMUM INTO CMU (GROUTEDSOLID). BOLTS ARE TO BE 16"O.C., STAGGERED.PROVIDE (1) CONTINUOUS BONDBEAM AT EACH LANDING w/ (1) #4.FULLY GROUT MIN (2) COURSESBELOW, TYP.(2) 11 1/4" PERIMETER LVL, TYP.TYPICAL LANDING:1 1/4" GYPSUM CONCRETE FLOOR3/4" OSB SUBFLOOR2x12 FLOOR JOISTS @ 16" O.C.5/8" TYPE 'X' GYPSUM BOARD2-HOUR SHAFT LID ASSEMBLY,PER UL ASSEMBLY ON G0058A651PRESSURE TREATED 2x43/4" OSB SHEATHING WOOD STAIR RISER2x10 AND RIPPED 2x4 WOOD STAIR TREADPREFORMED CONTRASTING VINYL NOSING TOCOMPLY WITH 2" VISUAL CONTRAST ATTHE LEADING EDGE AS REQUIRED BYSECTION 504.5.1 OF THE ICC/ANSI A117.1-2009.FINAL FINISH OF STAIR COVERING BY OWNER5 1/8"2 7/8"9 1/4"6 3/4"1" TYP.11 1/8"5/8" TYPE 'X'GYPSUM BOARD8"1'-6" MIN.8"MIN.8"4"PROVIDE MIN(4) STRINGERS.3/4" OSB SHEATHING WOOD STAIR RISER2x10 AND RIPPED 2x4 WOOD STAIR TREADPREFORMED CONTRASTING VINYL NOSINGTO COMPLY WITH 2" VISUAL CONTRAST ATTHE LEADING EDGE AS REQUIRED BYSECTION 504.5.1 OF THE ICC/ANSI A117.1-2009.5/8" TYPE 'X' GYP. BD.PROVIDE BLOCKINGBETWEEN STRINGERS @ 24"O.C.FINAL FINISH OF STAIR COVERING BY OWNER1 1/4 " POURED GYPSUM CONCRETEUNDERLAYMENT OVER 3/4" OSBSHEATHING, SEE STRUCTURAL DRAWINGSFOR FLOOR / LANDING FRAMING2 7/8"9 1/4"SECTIONSSEE11 1/8"5 1/8"(3) 1 3/4"x11 1/4" LVLPROVIDE MIN (4) STRINGERS -(1) EACH END AND (2) EQUALLYSPACED BETWEEN5/8" TYPE X GYP. BD.PREFORMED CONTRASTING VINYL NOSING TOCOMPLY WITH 2" VISUAL CONTRAST ATTHE LEADING EDGE AS REQUIRED BYSECTION 504.5.1 OF THE ICC/ANSIA117.1-2009.3/4" OSB SHEATHING WOOD STAIR RISER2x10 AND RIPPED 2x4 WOOD STAIR TREADFINAL FINISH OF STAIR COVERING BY OWNERPROVIDE BLOCKINGBETWEEN STRINGERS @24" O.C.1 1/4" POURED GYPSUM CONCRETE UNDERLAYMENTOVER 3/4" OSB SHEATHING, SEE STRUCTURAL &ARCH DRAWINGS FOR FLOOR / LANDING FRAMINGSECTIONSSEE1" TYP.2 7/8"9 1/4"(3) 1 3/4"x11 1/4" LVL5/8" TYPE 'X' GYPSUM BOARD BOTH SIDES2x4 SOLE PLATEACOUSTICAL SEALANT1 1/4" GYPSUM CONCRETE UNDERLAYMENTOVER 3/4" OSB FLOOR SHEATHINGSEE PLANS & SECTIONS FOR FLOOR /LANDING FRAMING5/8" TYPE 'X' GYPSUM BOARD1 1/2" DIA. METAL HANDRAILMETAL HANDRAIL BRACKET AS REQUIREDAND PROVIDED BY STAIR SUPPLIERSOLID BLOCKING FOR HANDRAIL2'-11 3/4" CLEAR1 1/2" CLEAR1 1/2" CLEARREVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED STAIR PLANS & SECTIONA600CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607430 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A6001STAIR A - 1ST FLOOR PLAN 1/4" = 1'-0"A6002STAIR A - 2ND FLOOR PLAN 1/4" = 1'-0"A6003STAIR A - 3RD FLOOR PLAN 1/4" = 1'-0"A6004STAIR A - 4TH FLOOR PLAN 1/4" = 1'-0"A6005SECTION - STAIR A 1/4" = 1'-0"A6006STAIR B - 1st FLOOR PLAN 1/4" = 1'-0"A6007STAIR B - 2ND FLOOR PLAN 1/4" = 1'-0"A6008STAIR B - 3RD FLOOR PLAN 1/4" = 1'-0"A6009STAIR B - 4TH FLOOR PLAN 1/4" = 1'-0"A60010SECTION - STAIR B 1" = 1'-0"A60011STAIR DETAIL @ BASE 1" = 1'-0"A60012STAIR RISER DETAIL @ LOWER LANDING 1" = 1'-0"A60013STAIR RISER DETAIL @ UPPER LANDING 1" = 1'-0"A60014STAIR HANDRAIL DETAIL3 9/7/2016 ADD. #33333
E7G6F7.27.5007ELEVATOR LOBBY035ELEV. EQ. RM0G20 HR2E2 HR0F0 HR0F0 HR2D12 HR2D12 HR0G10 HR1 1/2"19'-0"1 1/2"2'-0 1/8"13'-2"3'-9 7/8"8 3/8"8'-8"4"8'-0 5/8"19'-0"6'-1 5/8"3 3/8"5"8'-8"4"7'-6"5'-0"4'-9 3/8"3'-10"2'-0 1/4"3'-10"4'-9 3/8"7'-7 3/4"ELEV. #2ELEV. #13'-2 5/8"12'-9 3/4"3'-2 5/8"2A6511A65124x84 STR E TC H ER
EH57G6F7.27.5219LINEN225ELEC.217ELEVATOR LOBBY250CORR.251CORRIDOR0F0 HR2E2 HR1A1 HR1A1 HR1L11 HR0G20 HR0F0 HR2E2 HR1A1 HR15'-2 1/8"3'-9 7/8"2'-0 1/4"19'-0"1 1/4"9'-0"8'-0"6'-1 3/8"6'-9"18'-2"5'-7 3/8"7'-0" OPNG3'-6"3'-0"0G20 HR2A6511A6511L11 HR8'-7 3/4"2'-0"8'-2 1/2"11'-1 1/4"2S2 HR1L11 HR2S2 HR1L11 HR223TELE/ DATA221VENDING2'-1 5/8"1'-11 1/2"2232252192'-9 1/2"24x84 STR E TC H ER
H.8H.25'-0"4'-9 3/8"3'-10"2'-0 1/4"3'-10"4'-9 3/8"8'-8"4"19'-6 1/2"EH57G6F7.27.52A651319LINEN3291 BR SUITE 03325ELEC.317ELEVATOR LOBBY351CORRIDOR350CORR.315KING 011A6512S2 HR1A11 HR1L11 HR1L11 HR1L11 HR0G20 HR2E2 HR0F0 HR1 HR1L11 HR1 HR2S2 HR1A1 HR1L11 HR0F0 HR323TELE/DATA321VEND'G3 1/8"9'-0"8'-0"6'-1 3/8"6'-9"5'-7 7/8"4'-9 3/8"3'-10"2'-0 1/4"3'-10"4'-9 3/8"5'-0"8'-7 3/4"2'-0"8'-0 1/2"11'-3 1/4"2'-1 5/8"1'-11 1/2"3'-0"7'-0" OPNG3'-6"5'-7 3/8"5'-0"3'-9 7/8"15'-2 1/8"2'-0 1/4"19'-0"8'-8"4"8'-0"11'-7 1/8"6'-11 1/4"2'-9 1/2"3193253238"24x84 S TRETC HER
H.8H.2EH57G6F1A3001A3002A3002A3007.27.52A651419LINEN425ELEC.417ELEVATOR LOBBY451CORRIDOR450CORR.415KING 014291 BR SUITE 031A651423TELE/ DATA421VEND'G2S2 HR0F0 HR2E2 HR1A1 HR2S2 HR1A1 HR1L11 HR1A1 HR1 HR1 HR0G20 HR2E2 HR0F0 HR3 1/8"9'-0"8'-0"6'-1 3/8"6'-9"4'-9 3/8"3'-10"2'-0 1/4"3'-10"4'-9 3/8"5'-0"2'-1 5/8"1'-11 1/2"5'-0"5'-7 3/8"7'-0" OPNG3'-6"3'-0"3'-9 7/8"15'-2 1/8"2'-0 1/4"19'-0"8'-8"4"8'-0"11'-7 1/8"6'-11 1/4"2'-9 1/2"1L11 HR1L11 HR1L11 HR8'-7 3/4"1'-11 3/8"8'-7 7/8"10'-8 1/2"24x84 S TRETC HER
H.8H.2423425419REVISIONSPROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED ELEVATOR PLANSA650CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607431 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A6501ENLARGED ELEVATOR PLAN - 1st FLR 1/4" = 1'-0"A6502ENLARGED ELEVATOR PLAN - 2ND FLR 1/4" = 1'-0"A6503ENLARGED ELEVATOR PLAN - 3RD FLR 1/4" = 1'-0"A6504ENLARGED ELEVATOR PLAN - 4TH FLRGENERAL NOTES - ELEVATOR1 ELEVATOR SELECTED FOR COMPLIANCE WITH 2016 CBC, COORDINATE ELEVATORSHAFT SIZE WITH SELECTED MANUFACTURER.2 AT LEAST ONE ELEVATOR SHALL BE PROVIDED FOR FIRE DEPARTMENTEMERGENCY ACCESS TO ALL FLOORS. SUCH ELEVATOR CAR SHALL BE OF SUCH ASIZE AND ARRANGEMENT TO ACCOMMODATE A 24"x84" AMBULANCE STRETCHER INTHE HORIZONTAL, OPEN POSITION AND SHALL BE IDENTIFIED BY THEINTERNATIONAL SYMBOL FOR EMERGENCY MEDICAL SERVICES (STAR OF LIFE).THE SYMBOL SHALL NOT BE LESS THAN 3" HIGH AND SHALL BE PLACED INSIDE ONBOTH SIDES OF THE HOISTWAY DOOR FRAME.3 CONTRACTOR SHALL VERIFY AND ADJUST ELEVATOR PIT DEPTH, HOISTWAY, ANDOVERHEAD TO MATCH MANUFACTURERS ELEVATOR REQUIREMENTS.4 PROVIDE, AT EACH LANDING, A SIGN INDICATING DIRECTION OF EGRESS ANDLABELED THE FLOOR LEVEL, THE SIGN SHALL READ "IN FIRE EMERGENCY, DO NOTUSE ELEVATOR, USE EXIT STAIRS", THE SIGN SHALL BE LOCATED 60"A.F.F. ANDCENTERED BETWEEN DOOR JAMBS. ELEVATOR SHALL HAVE HANDRAILS ON BOTHSIDES OF CAB INTERIOR.5 CONTRACTOR TO PROVIDE IRONITE (OR EQUIVALENT) WATERPROOFING SYSTEMAND FOUNDATION DRAINAGE BOARD TO ENTIRE ELEVATOR PIT ALONG OUTSIDEPERIMETER TO PREVENT ANY WATER INFILTRATION.6 ELEVATORS ARE BASED ON SCHINDLER 330A HYDRAULIC ELEVATORS. IFELEVATOR SELECTION DIFFERS, THEN THE G.C. SHALL BE RESPONSIBLE FOR THEREDESIGN OF THE ELEVATOR REQUIREMENTS AND SPECIFICATIONS IN ITSENTIRETY.7 INITIAL ELEVATOR INSPECTION SHALL BE BY THE GENERAL CONTRACTOR.8 FIELD VERIFY ALL DIMENSIONS PRIOR TO STARTING WORK9 GENERAL CONTRACTOR SHALL PATCH AND FINISH TO MATCH ALL OPENINGSCREATED BY CONSTRUCTION BY OTHER TRADES.10 PATCH CONCRETE FLOOR SMOOTH IN AREAS ADJACENT TO ELEVATORENCLOSURE AND SILL ASSEMBLY (TYP. AT ALL FLOOR LEVELS). PIT AND ALL FLOOROPENINGS MUST BE IN-LINE AND PLUMB.11 AT ELEVATOR ENCLOSURE, INTERIOR FACE OF NEW MASONRY WALLS SHALL BEFLUSH. PATCH/REPAIR ROUGH MASONRY SURFACES TO FORM SMOOTH FINISH.12 CONSTRUCTION TOLERANCES FOR INTERIOR FACE OF NEW MASONRY ATELEVATOR ENCLOSURE:MAX. VARIATION FROM PLUMB: ¼” IN TEN FEET (VERTICAL LINES & SURFACES)MAX. VARIATION FROM LEVEL: ¼” IN TWENTY FEET.MAX. VARIATION FROM LINEAR BUILDING LINE: ½” IN TWENTY FEET.MAX. VARIATION IN CROSS SECTIONAL DIMENSIONS IN WALL THICKNESS: MINUS ¼”NOR. PLUS ½”.MAX. VARIATION IN MORTAR JOINT THICKNESS: ⅛” (WITH MAX. JOINT THICKNESSLIMITED TO ½”).13 HORIZONTAL JOINT REINFORCEMENT: REINFORCE WALLS WITH CONTINUOUSHORIZONTAL JOINT REINFORCEMENT, ZINC COATED (GALVANIZED) STEEL WIRE,3/16” WIRE SIZE FOR SIDE RODS, TRUSS DESIGN WITH CONTINUOUS DIAGONAL (9GA.) CROSS RODS SPACED NOT MORE THAN 16” O.C. FOR SINGLE WYTHE WALLS,SPACE REINFORCEMENT AT 16” O.C. VERTICALLY, UNLESS OTHERWISE INDICATED.14 REINFORCE MASONRY OPENINGS WITH HORIZONTAL JOINT REINFORCEMENTPLACED IN TWO (2) HORIZONTAL JOINTS APPROXIMATELY 8” APART, IMMEDIATELYABOVE THE LINTEL. EXTEND REINFORCEMENT A MINIMUM OF 2 FEET BEYONDJAMBS OF THE OPENING.15 GENERAL CONTRACTOR TO INSTALL ALL MASONRY INSERTS (FOR ELEVATOREQUIPMENT & TRACK) PROVIDED BY ELEVATOR CONTRACTOR. BRICK TYPE INSERTTO BE INSTALLED SURROUNDED BY 7 COURSE OF BRICK, AND LOCATED WITHIN2’-0” MAXIMUM OF EACH FLOOR (TYP.) AND 10’-0” MAX. ABOVE TOP LANDING (TYP.).AT CONCRETE SURFACES, LAG BOLT BRACKETS INTO WALL OR INSTALL SPIDERINSERTS.16 STEEL LADDER BY GENERAL CONTRACTOR. LOCATE LADDER IN ELEVATORENCLOSURE AS DIRECTED BY ELEVATOR CONTRACTOR. INSTALL LADDER AFTERSTART OF ELEVATOR COMPONENT INSTALLATION.17 GROUP SOLID ALL BLOCK MASONRY WALL CORES INCLUDING CORES LOCATEDABOVE AND BELOW MASONRY INSERTS SUPPORTING ELEVATOR TRACK. GROUTEDAREA SHALL BE 4’-0” WIDTH (SURROUNDING EACH INSERT) X FULL HEIGHT OF WALL.18 HOISTWAY ENTRANCES ARE 1-½ HOUR FIRE RATING LABEL - UL. (MIN.).19 HOISTWAY WALLS AT ENTRANCES ARE TO BE BUILT AFTER DOOR SILLS & FRAMESARE SET IN PLACE. IF THIS IS NOT POSSIBLE, LEAVE 4’-10” W. X 7’-8” H. ROUGHOPENING. FILL ALL BLOCK MASONRY WALL CORES WITH CONCRETE, A MINIMUM OF6” ABOVE AND BELOW THE FINISH FLOOR LINE (FULL WIDTH OF HOISTWAY).20 VERIFY ALL DIMENSIONS SHOWN ON THIS DRAWING WITH ELEVATORMANUFACTURER’S REQUIREMENTS.4 6/25/2018 BULLETIN #14
Floor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"EGElevator Pit-5'-4"FElevator roof52'-0 7/8"007ELEVATOR LOBBY217ELEVATOR LOBBY317ELEVATOR LOBBY417ELEVATOR LOBBY035ELEV. EQ. RM215KING 01315KING 01415KING 011A651Truss Bearing45'-10 3/8"PROVIDE SUMP PUMP ANDWATERPROOFING ATELEVATOR PIT PER LOCALCODE REQUIREMENTSELEVATOR CABSHOWN FORREFERENCE ONLYHOISTWAY BEAM - COORDINATEWITH STRUCTURAL DRAWINGS &ELEVATOR SUPPLIER FOR HEIGHTFloor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"7Elevator Pit-5'-4"67.2Elevator roof52'-0 7/8"2A651451CORRIDOR351CORRIDOR251CORRIDOR003WELCOME LOBBY010COFFEE HOUSEPUB219LINEN319LINEN419LINENTruss Bearing45'-10 3/8"PROVIDE SUMP PUMP ANDWATERPROOFING ATELEVATOR PIT PER LOCALCODE REQUIREMENTSELEVATOR PIT LADDERREFER TO DETAIL 4/A651ELEVATOR CABSHOWN FORREFERENCE ONLYELEVATOR CABSHOWN FORREFERENCE ONLYTHICKENED SLABAT THRESHOLDC.M.U. WALLHOISTWAY BEAM - COORDINATEWITH STRUCTURAL DRAWINGS &ELEVATOR SUPPLIERSLOPED 2x10 ROOF FRAMING MEMBERS,REFER TO STRUCTURAL DRAWINGS. PROVIDER-30 BATT INSULATION WITHIN CAVITY.2 HR SHAFT LID ASSEMBLY, PERUL ASSEMBLY ON SHEET G0052 HR ELEVATOR WALLASSEMBLY, PER ULASSEMBLY ON SHEET G004MOTORIZED CONTROL SMOKE DAMPER (RUSKINCD36, OR EQUAL) WITH POWER CLOSED/FAIL OPENIN-STREAM ACTUATOR. ACTUATOR TO BEINTERLOCKED WITH FIRE ALARM SYSTEM AND OPENUPON DETECTION OF SMOKE.PROVIDE A WEATHER HOOD W/ PREFAB CURB OVERDAMPER, GREENHECK ESD-635PD OR EQUAL.TYP.TYP.TYP.TYP.TYP.TYP.TYP.TYP.6.26.3WALL MOUNTED LADDER FORROOF ACCESS THROUGH 1-HOURRATED ROOF HATCH. SEE ROOFPLAN FOR MORE INFORMATION.ELEVATOR DOORBY ELEVATORMANUFACTURERFINISH SILL BYELEVATORMANUFACTURERFASCIA BYELEVATORMANUFACTURERSTEEL ANGLE,ANCHOR TO PITWALL w/ 1/2" DIA.EXPANSIONANCHORS -COORDINATEWITH STRUCTURE4" CONCRETE SLABREINFORCED w/ 6x6 W1.4xW1.4W.W.F. ON 10 MIL. VAPORBARRIER OVER 10" POROUSFILL (VERIFY w/ STRUCTURAL)COORDINATE WITHELEVATORMANUFACTURER1/2" DIA. EXP.ANCHOR2 1/2" x 3/8" CLIPANGLES (3LOCATIONS)7/8" DIA. STEELRUNG w/ NON-SLIP FINISH2 1/2" x 3/8"STEEL RAILSNOTE:GRIND ALL WELDSSMOOTHNOTE:LADDER NOT TOOBSTRUCT CAB TRAVEL+/- 7"1'-5 7/8"FINISH JAMB BYELEVATORMANUFACTURERELEVATOR DOOR BYELEVATORMANUFACTURERFINISH SILL BYELEVATORMANUFACTURERFASCIA BY ELEVATORMANUFACTURERSTEEL ANGLE &THROUGH BOLT(S) -SEE STRUCTUREREBAR, SEESTRUCTURAL7'-4" A.F.F.CAULKFRAME BYELEVATORCONTRACTORFASCIA BY ELEVATORMANUFACTURERCOVER BY ELEVATORMANUFACTURERCOORDINATESTRUCTURE WITHSTRUCTURAL DRAWINGSELEVATOR DOOR BYELEVATORMANUFACTURERREBAR, SEESTRUCTURAL(4) 3/4" DIA. THRUBOLTSSUPPORTS BYELEVATORMANUFACTURERELEVATOR CABFloor 0215'-2"Floor 0325'-11 3/8"Floor 010"Floor 0436'-8 3/4"1Truss Bearing45'-10 3/8"1B1A1A32D12 HR2S2 HR2S2 HR2S2 HR21" x 21" SIDE HINGED LAUNDRYCHUTE DOOR TO BE 1.5 HOURRATING, 'B' LABELED WITHASSEMBLY BY MANUFACTURER.DOORS SHALL BE SELF-CLOSING,SELF-LATCHING, AND ULAPPROVED WITH LEVERHANDLES.21" x 21" SIDE HINGED LAUNDRYCHUTE DOOR TO BE 1.5 HOURRATING, 'B' LABELED WITHASSEMBLY BY MANUFACTURER.DOORS SHALL BE SELF-CLOSING, SELF-LATCHING, ANDUL APPROVED WITH LEVERHANDLES.24" x 30" TOP HINGED LAUNDRYCHUTE HOPPER-TYPEDISCHARGE DOOR TO BE 1.5HOUR RATING, 'B' LABELEDWITH ASSEMBLY BYMANUFACTURER. DOORSSHALL BE SELF-CLOSING, SELF-LATCHING, AND UL APPROVEDWITH LEVER HANDLESPROVIDE FLASHING ANDSEALANT AT ENTIREPERIMETER OF ROOFINGPENETRATION, PERMANUFACTURER'SRECOMMENDATIONS.GRAVITY VENT BEYONDSUPPORT PEDESTALAUTOMATIC SPRINKLERTHICKENED SLAB, REFER TOSTRUCTURAL DRAWINGS.2'-0" DIAMETER CHUTENOTE:SUPPRESSION CONTRACTOR TOPROVIDE FIRE SUPPRESSION W/INTHE SHAFT PER NFPA 13.AUTOMATIC SPRINKLERAUTOMATIC SPRINKLER4'-0" MIN.REVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ELEVATOR SECTIONS & DETAILSA651CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607432 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A6512ELEVATOR SECTION - NORTH SOUTH 1/4" = 1'-0"A6511ELEVATOR SECTION - EAST WEST 1 1/2" = 1'-0"A6513ELEVATOR SILL @ SLAB 1 1/2" = 1'-0"A6514WALL LADDER PLAN 1 1/2" = 1'-0"A6515ELEVATOR SILL (UPPER FLOORS) 1 1/2" = 1'-0"A6516ELEVATOR HEAD 1 1/2" = 1'-0"A6517GUIDE RAIL3 9/7/2016 ADD. #3 1/2" = 1'-0"A6518LINEN CHUTE SECTION3
42"60"TV60"60"BB.5
7.5
8.8
A7007
8
5
6 2'-5 1/8"3'-0"2'-4"2'-7 7/8"6'-2 1/4"5 3/4"6'-0 1/2"2'-0"0G
0 HR0A
0 HR
0G
0 HR
0G
0 HR5 1/2"3'-0 1/2"5'-8 1/4"3 1/2"20'-5"5 1/2"8"1'-5 1/2"6'-1 1/4"5 1/2"2'-10 3/4"3 1/2"25'-7"5 1/2"3 1/2"2'-11"
12'-8 1/2"
1L1
1 HR
1L1
1 HR
0A
0 HR
0A
0 HR
0G
0 HR
VTACVTAC ACCESS
PANEL
A700
9
10
11
12
1L1
1 HR
0G
0 HR
8
GST-200
GST-103
GST-107
GST-908
GST-110
LT-01
GST-112
GST-701
GST-502
RF-01
RB-01
RF-01
RB-01
LT-02 GST-118
GST-300
GST-111
GST-101
GST-900
GST-700
GST-400
GST-302
GST-502
M-05
UNDERMOUNT
LAV. BY G.C.
GST-304
GST-500
GST-109
GST-122
9
8'-3"GWB
8'-0"
GWB
8'-11 5/8"
GWB
7'-6"
GWB
8'-0"3'-6"3'-0"1'-0"1'-0"12'-0"1'-6"1'-11"3'-3"7'-9"6'-9"6'-0"
9
RB-01
WC-01 WC-01
CL
GST-100
GST-900
GST-111
7'-1"14'-8 1/2"3'-9"
WC-01
RB-01
WC-01
OPEN
WC-02
RB-01
FEATURE WALL
OPEN
GLASS PANEL
BEHIND
SLIDING GLASS
DOOR
LT-02
WC-01
PT-03
RB-01
ART
LT-02
DUAL ROLLER SHADE
GST-700
GST-4001'-7 7/8"
WC-03
RB-01
WC-03
48" BACKLIT
MIRROR
OPEN LT-01
3'-5"6'-6"ART
T-03
RB-01
GST-701
M-07
CL
4'-11"4'-3"1'-4"CL
(VALVE)4'-0"1'-0"CL
WC-03
LT-01
T-03
WC-03STATIONARY
GLASS
PANEL
WC-03
RB-01
PT-04
PL-01
WC-01
M-07
M-07
1'-4"
3'-0"
WC-03
OPEN
LT-01T-03
STATIONAR
Y GLASS
PANEL
M-07
1'-0"1'-0"39"-41"FIN FLR.
ADA TOILET
16"-18"
7"-9"MIN15"4'-0"3'-4"MAX TO REFLECTED SURFACEACCESSIBLE MIRROR ADA ROOM
NOTE: ALL HORIZONTAL GRAB BARS SHALL BE MOUNTED 33"-36" FROM
FINISHED FLOOR TO TOP OF GRIPPING SURFACE, UNLESS NOTED
OTHERWISE.
MAX
12"
54" MIN
1 1/2"2"
39"-41"5'-0"ACCESSIBLE ROOMS4'-0"G18
G42
G24
B C A
G24
EQ EQ
BATHTUB
CONTROL
LOCATIO
N
HAND HELD
SHOWER AND
SLIDE BAR w/60"
HOSE
ADA ROOM
MAX
2'-0"
MAX
1'-0"9"3'-6"17"-19"ADA ROOM
4"2'-11"4"-6"G18
G24 G30 H
6'-6"2'-2"17"-19"3'-2"10"SHOWER
CONTROL
LOCATION
2'-3"
MAX
4"-6"
ADA ROOM
SHOWER
E
G42
MAX
4"-6"
ADA ROOM
SHOWER
G24
SHOWER 2'-9"G18
D F
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - KING 01A700CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607433 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A700
1 KING 01 - ARCH. PLAN
1/4" = 1'-0"A700
2 KING 01 - FF & E PLAN
1/4" = 1'-0"A700
3 KING 01 - RCP PLAN
1/4" = 1'-0"A700
4 KING 01 - ELECTRICAL PLAN
1/4" = 1'-0"A700
5 KING 01 ELEVATION
1/4" = 1'-0"A700
6 KING 01 ELEVATION
1/4" = 1'-0"A700
7 KING 01 ELEVATION
1/4" = 1'-0"A700
8 KING 01 ELEVATION
1/4" = 1'-0"A700
9 KING 01 BATH ELEV
1/4" = 1'-0"A700
10 KING 01 BATH ELEV
1/4" = 1'-0"A700
11 KING 01 BATH ELEV
1/4" = 1'-0"A700
12 KING 01 BATH ELEV
1/4" = 1'-0"A700
13 TOILET ACCESSORY MOUNTING HEIGHTS
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL DRAWINGS
1
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
9 06/05/2019 BULLETIN #6
42"60"TV60"60"4'-7 7/8"3'-0"6'-10 1/2"4'-1 7/8"5 1/2"12'-10 5/8"2'-0"5'-8 1/4"3'-1 1/2"3'-7 1/8"6'-0 1/4"
10 1/2"5 1/2"1'-4"13'-1 7/8"
2'-5 5/8"
5 1/2"
2'-9 3/8"3'-3"6'-6"5 5/8"6'-2 1/4"
GR2
GR1
10°
VTAC
VTAC
ACCESS
PANEL
A701
9
A701 7
8
5
6
12
11
10
0G
0 HR
0A
0 HR
1L1
1 HR
1L1
1 HR
0A
0 HR
1L1
1 HR
1L1
1 HR
IW1
8
8
0G
0 HR
7.5
GST-201
GST-500
GST-700
GST-502
GST-908
GST-400
GST-118
GST-300
GST-103
GST-107
GST-110
LT-01
GST-112
GST-701RF-01
RB-01
RF-01
RB-01
GST-205
GST-302
GST-502
M-05
UNDERMOUNT
LAV. BY G.C.
GST-206
GST-304
GST-900
GST-101
GST-109
GST-122
GST-111
9
GWB
8'-0"
GWB
7'-6"
GWB
8'-0"10'-8"1'-0"3'-0"
ALIG
N
GWB
8'-11 5/8"4'-6"2'-2"
1'-0"
6'-0"5'-3"42"17'-2"1'-6"4'-5 1/2"2'-0"7'-5 1/2"9
RB-01
WC-01
WC-01
3'-9 1/4"
GST-111 GST-10
0GST-900
CL 47" T.V.CL
PT-03
WC-01
RB-01
DUAL ROLLER
SHADE
GST-400
GST-700
ART
EQ EQ
FEATURE WALL
WC-02
RB-01
OPEN
GLASS
PANEL
BEHIND
SLIDING GLASS
DOOR
WC-01 WC-01
OPEN
RB-01
SLIDING DOOR MIRROR
SHELF REF.
RB-01
WC-03
48" BACKLIT
MIRROR
OPEN
3'-4"
LT-01
WC-03
WC-03
RB-01
T-03
ART
5'-1 1/4"1'-0"G18
J
1'-8"2'-3 1/2"1'-4"
GST-701
LT-01
M-07 WC-03
T-03
WC-03STATIONARY
GLASS PANEL
G18
B
6"
K
PT-04
PL-01
WC-01
M-07
M-073'-0"
1'-4"
T-03
STATIONARY
GLASS PANEL
OPEN LT-01
K
1'-0"1'-0"
C
C
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - KING 02A701CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607434 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A701
1 KING 02 - ARCH. PLAN
1/4" = 1'-0"A701
2 KING 02 - FF & E PLAN
1/4" = 1'-0"A701
3 KING 02 - RCP PLAN
1/4" = 1'-0"A701
4 KING 02 - ELECTRICAL PLAN
1/4" = 1'-0"A701
5 KING 02 ELEVATION
1/4" = 1'-0"A701
6 KING 02 ELEVATION
1/4" = 1'-0"A701
7 KING 02 ELEVATION
1/4" = 1'-0"A701
8 KING 02 ELEVATION
1/4" = 1'-0"A701
9 KING 02 BATH ELEV
1/4" = 1'-0"A701
10 KING 02 BATH ELEV
1/4" = 1'-0"A701
11 KING 02 BATH ELEV
1/4" = 1'-0"A701
12 KING 02 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL DRAWINGS
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
9 06/05/2019 BULLETIN #6
42"TV60"60"60"A7027
A702
9
6
5
8
10
11
12
VTAC
VTAC
ACCESS
PANEL
2'-7 7/8"2'-4"5'-5 1/8"0G
0 HR0G
0 HR
1L1
1 HR
2E
2 HR
0A
0 HR
0A
0 HR
1L1
1 HR
0G
0 HR
0A
0 HR
6'-0 3/8"5 3/4"6'-2 1/4"
12'-8 3/8"2 1/2"
3'-2 3/8"9'-6"3'-6 1/2"5'-8 1/4"3 1/2"20'-5"6"25'-7"3'-2 1/4"2'-0"ALIGN
GYPSUM
BOARD
0G2
0 HR
8
0G
0 HR
GST-200
GST-502
GST-304
GST-908
GST-110
LT-01
GST-112
GST-701
GST-502
RF-01
RB-01
RF-01
RB-01
LT-02
GST-118
GST-300
GST-111
GST-201
GST-101
GST-900
GST-700
GST-400
GST-302
GST-103
M-05
UNDERMOUNT
LAV. BY G.C.
GST-107
GST-500
GST-109
GST-122
GST-702
GST-703
9
ALIG
N
GWB
8'-0"
GWB
8'-0"
GWB
7'-6"
GWB
8'-11 5/8"3'-6"1'-0"3'-0"
1'-0"12'-0"6'-9"42"7'-8 5/8"3'-3"1'-11"1'-6"9
RB-01
WC-01 WC-01
14'-8 3/8"
GST-111GST-100
GST-900
CL47" T.V.
CL
CL
WC-01
PT-03
RB-01
ART
LT-02
DUAL ROLLER
SHADE
GST-700
GST-400
WC-02
RB-01
FEATURE WALL
OPEN
GLASS
PANEL
BEHIND
SLIDING GLASS
DOOR
LT-02
RB-01
WC-01WC-01
MIRROR SLIDING DOOR
SHELFREF.
WC-03
RB-01
WC-03
48" BACKLIT
MIRROR
OPEN
LT-01 ART
T-03
RB-01
GST-701M-07
CL
1'-0"4'-0"T-03WC-03 STATIONARY
GLASS PANEL
WC-03
RB-01
PT-04
PL-01
WC-01
M-07
M-07
WC-03
OPEN
LT-01 T-03
STATIONAR
Y GLASS
PANEL
M-07
1'-0"1'-0"
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - KING 03A702CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607435 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A702
1 KING 03 - ARCH. PLAN
1/4" = 1'-0"A702
2 KING 03 - FF & E PLAN
1/4" = 1'-0"A702
3 KING 03 - RCP PLAN
1/4" = 1'-0"A702
4 KING 03 - ELECTRICAL PLAN
1/4" = 1'-0"A702
5 KING 03 ELEVATION
1/4" = 1'-0"A702
6 KING 03 ELEVATION
1/4" = 1'-0"A702
7 KING 03 ELEVATION
1/4" = 1'-0"A702
8 KING 03 ELEVATION
1/4" = 1'-0"A702
9 KING 03 BATH ELEV
1/4" = 1'-0"A702
10 KING 03 BATH ELEV
1/4" = 1'-0"A702
11 KING 03 BATH ELEV
1/4" = 1'-0"A702
12 KING 03 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL DRAWINGS
1
11
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
9 06/05/2019 BULLETIN #6
42"60"TV60"4
A703
9
A7037
6
8
5
10
11
12
VTAC ACCESS
PANEL
VTAC
H.2 3'-0"3'-0"6'-10 3/4"
0A
0 HR
1L1
1 HR
1L1
1 HR
0G
0 HR0G
0 HR
0G
0 HR
0A
0 HR
0A
0 HR
4.5
8
0G
0 HR
4
RF-01
RB-01
RF-01
RB-01
GST-111
GST-701
LT-01
GST-104
GST-200
GST-400
GST-110
GST-101
GST-201
GST-109
GST-900
LT-02
GST-301
GST-112
GST-500
GST-118
GST-303
GST-301
GST-303
M-05
GST-502
GST-106
UNDERMOUNT
LAV. BY G.C.
H.2
4.5
GWB
8'-11 5/8"
GWB
8'-0"
GWB
8'-0"3'-6"3'-0"EQ.EQ.1'-0"8'-9 1/2"8'-8"42"4'-6 1/4"4'-3 1/2"WC-01
WC-01
RB-01
GST-111
GST-101GST-900
SLIDING MIRROR
47" T.V.
SHELF
REF.
CL
CL WC-01
PT-03
RB-01
LT-02
DUAL ROLLER
SHADE
GST-400
WC-02
FEATURE WALL
RB-01
OPEN
GLASS
PANEL
BEHIND
SLIDING GLASS
DOOR
LT-02
WC-01
RB-01
OPEN
WC-03
RB-01
WC-03
48" BACKLIT
MIRROR
OPEN
LT-01
WC-03T-03
RB-01
LT-01
ART
RB-01
GST-701M-07
T-03
WC-03
WC-03
RB-01
PT-04
PL-01
WC-01
M-07
STATIONARY
GLASS
PANEL
LT-01
OPEN
T-03
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - DQ 02A703CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607436 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A703
1 DBL QUEEN 02 (DQ02) - ARCH. PLAN
1/4" = 1'-0"A703
2 DBL QUEEN 02 (DQ02) - FF & E PLAN
1/4" = 1'-0"A703
3 DBL QUEEN 02 - RCP PLAN
1/4" = 1'-0"A703
4 DBL QUEEN 02 (DQ02) - ELEC. PLAN
1/4" = 1'-0"A703
5 DQ 02 ELEVATION
1/4" = 1'-0"A703
6 DQ 02 ELEVATION
1/4" = 1'-0"A703
7 DQ 02 ELEVATION
1/4" = 1'-0"A703
8 DQ 02 ELEVATION
1/4" = 1'-0"A703
9 DQ 02 BATH ELEV
1/4" = 1'-0"A703
10 DQ 02 BATH ELEV
1/4" = 1'-0"A703
11 DQ 02 BATH ELEV
1/4" = 1'-0"A703
12 DQ 02 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS.
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
TV60"42"60"7.5
A704 5
6
7
8
A704
9
10
11
12
1'-5 1/2"6'-1 7/8"
5 1/2"
4'-10 1/2"3'-6 1/2"5'-8 1/4"3 1/2"20'-11"5'-4"7'-0 3/8"5'-8 1/4"
12'-8 5/8"3'-3"13'-2"8"26'-7"3 1/2"2'-10 3/4"30'-5 1/4"0A
0 HR
0G
0 HR
0G
0 HR
1L1
1 HR
0G
0 HR
1L1
1 HR
1L1
1 HR
0A
0 HR
VTAC
3'-0"IW1
GR1
GR2
8.9
8
1L1
1 HR
1L1
1 HR
7.5
RF-01
RB-01
RF-01
RB-01
GST-111
GST-106
GST-701
LT-01
GST-104
GST-200
GST-400
GST-110
GST-101
GST-201
GST-301
GST-500
GST-900
LT-02
GST-109
GST-112
GST-118
GST-303
GST-301
GST-303
GST-502
M-05
UNDERMOUNT
LAV. BY G.C.
8.9
GWB
8'-0"
GWB
8'-0"8'-3 5/8"1'-6"ALIGN
GWB
8'-11 5/8"
2'-2"3'-6"3'-0"1'-0"EQ.EQ.1'-6"4'-6 1/4"4'-3 1/2"8'-9 1/2"6'-0"
42"8'-8"WC-01
WC-01
RB-01
17'-8 5/8"8'-2 1/2"
GST-111
GST-101GST-900
CL
SLIDING
47" T.V.
SHELF
REF.
CL
WC-01
PT-03
RB-01
LT-02
DUAL ROLLER
SHADE
GST-400
WC-02
FEATURE WALL
RB-01
OPEN
GLASS PANEL
BEHIND
SLIDING GLASS
DOOR
LT-02
WC-01
RB-01
OPEN
WC-03
RB-01
WC-03
OPEN
48" BACKLIT
MIRROR
LT-01
1'-4"
WC-03
T-03
RB-01
LT-01
ART1'-0"B
4'-3"
G18
J
GST-701
M-07
T-03WC-03
STATIONARY
GLASS
PANEL
WC-03
RB-01
PT-04
B
G18
K
1'-4"
PL-01
WC-01
M-07
M-07
3'-0"
STATIONARY
GLASS PANEL
LT-01
OPEN T-03
K
C
C
2'-0"M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - DQ 04A704CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607437 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A704
1 DBL QUEEN 04 (DQ04) - ARCH. PLAN
1/4" = 1'-0"A704
2 DBL QUEEN 04 (DQ04) - FF & E PLAN
1/4" = 1'-0"A704
3 DBL QUEEN 04 (DQ04) - RCP PLAN
1/4" = 1'-0"A704
4 DBL QUEEN 04 (DQ04) - ELEC. PLAN
1/4" = 1'-0"A704
5 DQ 04 ELEVATION
1/4" = 1'-0"A704
6 DQ 04 ELEVATION
1/4" = 1'-0"A704
7 DQ 04 ELEVATION
1/4" = 1'-0"A704
8 DQ 04 ELEVATION
1/4" = 1'-0"A704
9 DQ 04 BATH ELEV
1/4" = 1'-0"A704
10 DQ 04 BATH ELEV
1/4" = 1'-0"A704
11 DQ 04 BATH ELEV
1/4" = 1'-0"A704
12 DQ 04 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
42"42"60"TV60"60"TV60"4'-9"6'-1 1/4"
6 5/8"
4'-9 3/4"2'-5 1/8"5'-4"2'-2"1'-11 7/8"3'-2 1/2"13'-7 3/8"2'-9 3/8"4'-3 1/4"2'-4 3/4"6"13'-7 1/4"3 1/2"2'-11 1/2"10°
VTAC
VTAC VTAC
ACCESS
PANELVTAC ACCESS
PANEL
ROD &
SHELF
GR4
GR5
GR2
GR1
A705 5
6
7
8
A705 9
10
11
12
A705
13
14
15
16
1L1
1 HR
1L1
1 HR
0A
0 HR
0A
0 HR
0G
0 HR
1L1
1 HR
1L1
1 HR
0G
0 HR
0A
0 HR
0A
0 HR 3'-3"8"6'-6 1/8"3'-2 1/2"16'-10 3/8"3 1/2"2'-11 1/2"30'-6"13'-2"
GR6
IW1
3'-0"13'-0 7/8"6 5/8"6'-0 1/4"
9'-10 3/8"
3 1/2"
2'-11"
3'-7 1/2"9'-10 3/4"
12'-8 3/8"
H.8
8
1L1
1 HR
1L1
1 HR
GST-100
GST-500
GST-900
GST-300GST-105
GST-502 GST-122
GST-111
GST-102
GST-900
LT-02
GST-200
GST-400
GST-201
GST-207
GST-701
GST-112
LT-01
GST-116
GST-501
GST-202
GST-400
GST-702
GST-700
GST-11
8
GST-11
8
GST-703
RF-01
RB-01
M-05
RF-01
RB-01
GST-302
GST-103
GST-502
UNDERMOUNT
LAV. BY G.C.
H.8
GWB
8'-0"
GWB
8'-0"
GWB
7'-6"
GWB
8'-0"3'-6"8'-3 5/8"1'-6"1'-2"2'-2"ALIG
N
3'-0"1'-0"GWB
8'-11 5/8"
GWB
8'-11 5/8"EQ.EQ.6'-0"
2'-2"
1'-2"14'-4 1/8"6'-11"1'-8"3'-0"3'-9 1/2"7'-5"2'-3"
42"1'-6"2'-0"60"
60"
60"
60"3'-8"RB-01
WC-01
WC-01
WC-01
PT-05
4'-10 7/8"
PL-04
GST-111
GST-100GST-900
47" T.V.CL
CL
RB-01
PT-03
WC-01
ART
DUAL ROLLER
SHADE 1'-9"
GST-700
GST-400
RB-01
WC-01
PT-05
OPEN
GLASS
PANEL
BEHIND
SLIDING GLASS
DOOR
ART
8'-5 7/8"GST-703
PL-01
5'-2"RB-01
OPEN
COUNTERTOP
W/ BACK
SPLASH
SINK BASE W/
PULLS
BASE CABINET
W/ PULLS
WC-01
1/8"3'-0"3'-0"
1/8"
WC-11
RB-01
WC-01
PT-04
3'-10 3/4"
PL-01
GST-90
0GST-102
47" T.V.5'-3 7/8"PT-03
WC-01
RB-01
LT-02
DUAL ROLLER
SHADE
GST-40
0
WC-02
FEATURE
WALL
RB-01
LT-02
WC-01PT-04
RB-01
GST-702
ART
PL-01
3'-10 7/8"
48" BACKLIT
MIRROR
WC-03
RB-01
WC-03
LT-01 OPEN
3'-5"
ART
WC-03
RB-01
WC-03
T-03
1'-4"4'-0"1'-0"4'-3"
J
G18
GST-70
1
LT-01
M-07
T-03
WC-03
WC-03
STATIONARY
GLASS PANEL
RB-01
8"
B
G18
K
1'-4"
PL-01
WC-01
PT-04
WC-03
M-07
M-07
3'-0"
WC-03
T-03
STATIONARY
GLASS PANEL
OPEN
K
LT-01
C
C
4"1'-0"M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED ONE-BEDROOM SUITE 01A705CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607438 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A705
1 ONE BEDRM SUITE 01 - ARCH. PLAN
1/4" = 1'-0"A705
2 ONE BEDRM SUITE 01 - FF & E PLAN
1/4" = 1'-0"A705
3 ONE BR SUITE 01 - RCP PLAN
1/4" = 1'-0"A705
4 ONE BEDRM SUITE 01 - ELEC. PLAN
1/4" = 1'-0"A705
5 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
6 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
7 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
8 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
9 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
10 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
11 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
12 ONE BR SUITE 01 ELEV
1/4" = 1'-0"A705
13 ONE BR SUITE 01 BATH ELEV
1/4" = 1'-0"A705
14 ONE BR SUITE 01 BATH ELEV
1/4" = 1'-0"A705
15 ONE BR SUITE 01 BATH ELEV
1/4" = 1'-0"A705
16 ONE BR SUITE 01 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
33
33 42"60"60"TV60"TV60"42"42"42"J
7.5
9
8.8
8
L
A7065
6
7
8
A7069
10
11
12
A706 1315
14
A706 16
17
18
19
VTAC
VTAC
33'-0 3/4"5'-3 1/2"
3 1/2"
1'-6 5/8"3'-0"7'-2 5/8"27'-0 7/8"1'-2"GR1
GR2
IW1
GR4
GR5
7'-2 1/4"3 1/2"3'-1 1/8"
15'-8 5/8"3 1/2"10'-8 1/4"1'-2"2'-4 5/8"5 1/8"3'-0 1/8"
3 1/2"
3'-8 1/2"
3 1/2"4 7/8"14'-3 7/8"3 1/2"2'-6 1/4"2 '-1 0 5/8"3'-0"2'-4"4'-1 7 /8"3 1/2"4'-9 7/8"3 1/2"100°1
00°
3 1/2"
4'-7 7/8"
5 1/2"2'-7 7/8"3 1/2"20'-7 5/8"1'-2"N
WHIRLPOOL -REFER
TO PLUMBING
1L1
1 HR
8
8
J
9
8
M
GST-103
GST-105
GST-300
GST-900
GST-100
GST-111
GST-108
GST-400
GST-701
GST-112
LT-01
GST-117
GST-102
GST-900
GST-10
5
GST-20
1
GST-501
GST-206
GST-208
GST-119
GST-702
GST-703
GST-501
GST-207
RF-01
RB-01
RF-01
RB-01
RF-01
RB-01
GST-11
8
GST-302
GST-400
GST-502
GST-105
GST-502
M-05
GST-122
(2) UNDERMOUNT
LAV. BY G.C.
N
GWB
8'-0"
GWB
8'-0"10'-3 1/4"4'-0"GWB
8'-11 5/8"
GWB
8'-11 5/8"
GWB
8'-11 5/8"
7 '-0 "
5'-6"2'-4"2'-5"3'-0"1'-0"1'-8"1'-5"2'-0"EQEQ2'-10"
1'-4"7'-6"3'-0"5'-6"5'-4"4'-6"2'-5"7'-0"
RB-01
WC-01DUAL
MOTORIZED
ROLLER SHADEGST-400, TYP.
PT-03
PT-05
WC-01
RB-01
DUAL
MOTORIZED
ROLLER SHADE
GST-111
GST-100
PL-04
GST-400
GST-900
PT-03
4'-2 7/8"
WC-01WC-01
OPEN
RB-01
GST-100
GST-900
47" T.V.
RB-01
WC-11
WC-01
PT-04
WC-01
SLIDING
GLASS PANEL
OPEN
GLASS
PANEL
BEHIND
PL-01
GST-900
GST-102
47" T.V.
RB-01
WC-01
DUAL ROLLER
SHADE
GST-400
PT-05
PL-04
PT-03
RB-01
WC-02
FEATURE
WALL
RB-01
WC-01PT-04
ART
GST-703
PL-01
6'-7 1/2"
RB-01
WC-01
ART
GST-702
RB-01
PT-04
WC-01
PL-01
OPE
N
RB-01
WC-01 WC-03 WC-03WC-03
T-03
J
1'-0"3'-6"RB-01
2'-6 3/4"
STATIONARY
GLASS PANEL
T-03
M-07
WC-03
72" BACKLIT
MIRROR
RB-01
WC-03
G18
WC-03
RB-01
WC-03
STATIONARY
GLASS PANEL
OPEN
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED ONE-BEDROOM SUITE 02A706CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607439 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A706
1 ONE BEDRM SUITE 02 - ARCH. PLAN
1/4" = 1'-0"A706
2 ONE BEDRM SUITE 02 - FF & E PLAN
1/4" = 1'-0"A706
3 ONE BR SUITE 02 - RCP PLAN
1/4" = 1'-0"A706
4 ONE BEDRM SUITE 02 - ELEC. PLAN
1/4" = 1'-0"A706
5 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
6 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
7 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
8 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
9 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
10 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
11 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
12 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
13 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
14 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
15 ONE BR SUITE 02 ELEV
1/4" = 1'-0"A706
16 1 BR STE 02 BATH ELEV
1/4" = 1'-0"A706
17 1 BR STE 02 BATH ELEV
1/4" = 1'-0"A706
18 1 BR STE 02 BATH ELEV
1/4" = 1'-0"A706
19 1 BR STE 02 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
42"60"TV60"60"TV60"A707 5
6
7
8
A707 9
10
11
12
A707
13
14
15
16
1'-1 3/8"3'-11 3/8"3'-11"12'-3 3/4"4'-9 7/8"17'-1 1/4"5 1/2"11'-7"8"2'-11 1/2"3 1/2"13'-1 1/2"3 1/2"2'-1 1/4"3 1/2"9"3 1/2"5'-7 5/8"3'-1 1/8"5 1/2"8"3'-8 1/2"5 1/2"3'-0"2'-4"8"1'-0 1/8"
3'-0"2'-10 7/8"5'-9 3/8"5 1/2"12'-8 1/2"1'-1"1L1
1 HR
1L1
1 HR
1L1
1 HR
0A
0 HR
0A
0 HR
0G
0 HR
0A
0 HR
0G
0 HR
1L1
1 HR
0G
0 HR
1L1
1 HR
0G
0 HR
VTAC
GR4GR3
GR2
GR1
IW13'-3"VTAC ACCESS
PANEL
10°
H.2
4.5
1L1
1 HR
0G
0 HR
8
5 6
GST-122
GST-201
GST-900 GST-100
GST-50
0
GST-501
GST-102
GST-500
GST-300
GST-400
GST-206
LT-01
GST-900
GST-501
GST-117
GST-204
GST-702
RF-01
RB-01
RF-01
RB-01RF-01
RB-01
GST-118
GST-302
GST-111
M-05
H.2
4.5
GWB
8'-0"
GWB
8'-0"GWB
8'-0"
3'-0"1'-0"GWB
8'-11 5/8"
GWB
8'-11 5/8"EQ.EQ.2'-8"8'-8"1'-8"7'-5"2'-10 1/4"6'-0 1/2"2'-11"
WC-01
RB-01
GST-900
GST-100
RB-01
WC-01
PT-04
RB-01
9'-8 1/4"
GST-111
GST-900
GST-10
0
WC-01
PL-01
47" T.V.
RB-01
WC-01
OPEN
CLOSET
OPEN
GLASS PANEL
BEHIND
SLIDING GLASS
DOOR
WC-11
PT-04 WC-01
RB-01
WC-01
ART
4'-11 1/2"
GST-702
PL-01
5'-2"RB-01
WC-01
GST-900
GST-102
47" T.V.
RB-01
WC-01 PT-03
DUAL
ROLLER
SHADE
GST-400
1
A411
Sim
RB-01
WC-02
FEATURE
WALL
WC-01
RB-01
PT-04
RB-01
WC-01
SLIDING
CLOSET
DOOR
PL-01
48" BACKLIT
MIRROR
WC-03
RB-01
WC-03
LT-01
1'-8"
WC-03
RB-01
WC-03
T-03
ART
J
B
G181'-0"LT-01
GST-70
1
M-07
1'-4"
T-03
WC-03
WC-03
STATIONARY
GLASS
PANEL
RB-01
B
G18
K
M-07
M-07
3'-0"
WC-03
T-03
STATIONARY
GLASS
PANEL
OPEN
K
LT-01
1'-0"1'-0"
C
C
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED ONE-BEDROOM SUITE 03A707CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607440 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A707
1 ONE BEDRM SUITE 03 - ARCH. PLAN
1/4" = 1'-0"A707
2 ONE BEDRM SUITE 03 - FF & E PLAN
1/4" = 1'-0"A707
3 ONE BR SUITE 03 - RCP PLAN
1/4" = 1'-0"A707
4 ONE BEDRM SUITE 03 - ELEC. PLAN
1/4" = 1'-0"A707
5 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
6 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
7 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
8 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
9 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
10 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
11 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
12 ONE BR SUITE 03 ELEV
1/4" = 1'-0"A707
13 1 BR STE 03 BATH ELEV
1/4" = 1'-0"A707
14 1 BR STE 03 BATH ELEV
1/4" = 1'-0"A707
15 1 BR STE 03 BATH ELEV
1/4" = 1'-0"A707
16 1 BR STE 03 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
42"60"TV 60"60"TV60"A7085
6
7
8
A708
9
10 11
A70812
13
14
15
A708
16
17
18
19
4'-10"5'-3 3/8"
6 5/8"
6'-1 1/4"1'-5 1/2"3 1/2"2'-6 1/4"3'-6 1/2"5'-8 1/4"3 1/2"9"3 1/2"2'-1 1/4"3 1/2"17'-5 3/4"8'-4 1/8"3 1/2"
6 5/8"
3'-0"8"2'-4"3'-1 3/8"2'-3 3/4"4'-2 1/2"3'-1 3/4"2'-10 7/8"
3 1/2"3 1/2"2'-11 3/4"GR4
GR3
GR2
IW1
GR1
0G
0 HR
1L1
1 HR
1L
1 HR
1L1
1 HR
1L1
1 HR
0A
0 HR
0A
0 HR
0G
0 HR
1L1
1 HR
0G
0 HR
0G2
0 HR5'-11 1/4"3'-1 1/8"9'-2 5/8"
3 1/2"
3'-2 1/2"
5 1/2"
VTAC ACCESS
PANEL
VTAC
1L
1 HR 10°
8.9
8
0G2
0 HR
8
1L1
1 HR
0G2
0 HR
7.5
GST-102
GST-103
GST-105
GST-111
GST-200
GST-201
GST-300
GST-500
GST-122
GST-100
GST-700
GST-501
RF-01
RB-01
RF-01
RB-01
RF-01
RB-01
GST-118
GST-11
8
LT-02
GST-502
GST-502
M-05
GST-302
GST-900
UNDERMOUNT
LAV. BY G.C.
8.9
C.5
GWB
8'-0"
GWB
8'-0"10 7/8"3'-2 1/4"1'-6"9'-0 3/8"
GWB
8'-0"
2'-3"5'-1 1/4"1'-6"6'-8"7'-0 1/4"
RB-01
WC-01 GST-702
ART
4'-7 1/4"5'-2"RB-01
WC-11
RB-01
WC-01
ACCENT WALLCOVERING
TO DIE AT INSIDE
CORNER.
GST-111
WC-01OPENWC-01 WC-01
RB-01
WC-01PT-04
5'-2 5/8"
GST-900
GST-100
PL-01
47" T.V.
RB-01
WC-01PT-04
PL-01
OPEN
RB-01
WC-01 WC-01
RB-01
WC-01
WC-01
OPEN
GLASS
PANEL
BEHIND
SLIDING GLASS
DOOR
WC-11
RB-01
WC-01
WC-01
7'-0 3/4"
GST-900
GST-102
47" T.V.
PT-03
RB-01
WC-01
ART
LT-02
DUAL ROLLER
SHADE
1'-8 7/8"1'-5"
GST-400
GST-700
WC-02
FEATURE
WALL
RB-01
LT-02
WC-01
SLIDING
CLOSET
DOOR
RB-01
PT-04
PL-01
48" BACKLIT
MIRROR
WC-03
RB-01
WC-03
LT-01
4'-3"1'-3 7/8"
WC-03
RB-01
WC-03
T-03
ART
J
G18
B 1'-0"4'-0"LT-01
GST-701 M-07
T-03
WC-03
WC-03
STATIONARY
GLASS
PANEL
RB-01
1'-4"
G18
KB
M-07
M-07
3'-0"
OPEN
WC-03T-03
STATIONARY
GLASS PANEL
K
LT-01
1'-0"1'-0"
M-07
C
C
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED ONE-BEDROOM SUITE 04A708CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607441 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A708
1 ONE BEDRM SUITE 04 - ARCH. PLAN
1/4" = 1'-0"A708
2 ONE BEDRM SUITE 04 - FF & E PLAN
1/4" = 1'-0"A708
3 ONE BR SUITE 04 - RCP PLAN
1/4" = 1'-0"A708
4 ONE BEDRM SUITE 04 - ELEC. PLAN
1/4" = 1'-0"A708
5 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
6 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
7 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
8 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
9 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
10 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
11 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
12 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
13 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
14 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
15 ONE BR SUITE 04 ELEV
1/4" = 1'-0"A708
16 1 BR STE 04 BATH ELEV
1/4" = 1'-0"A708
17 1 BR STE 04 BATH ELEV
1/4" = 1'-0"A708
18 1 BR STE 04 BATH ELEV
1/4" = 1'-0"A708
19 1 BR STE 04 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
TV60"42"60"A709 5
A70910
6
7
8
9
11
12
GR7
GR6
GR8
4'-9 7/8"
6"
4'-7"3'-0 1/2"8"6"26'-1"3 1/2"2'-11 1/2"30'-6"6"7'-3 3/4"3 1/2"2'-8 1/2"3 1/2"19'-4 3/4"10"3'-2"5'-4"5'-10 1/8"
8"
6'-2 3/8"2'-0"2'-0 1/4"2'-7 5/8"3 1/2"2'-11 1/2"VTA
C
VTAC ACCESS
PANEL
0A
0 HR
0G
0 HR
0A
0 HR
0G
0 HR
1L1
1 HR
1L1
1 HR
0A
0 HR
0G2
0 HR
12'-8 1/2"
H.8
1L1
1 HR
8
0G2
0 HR
1L1
1 HR
1L1
1 HR
RF-01
RB-01
RF-01
RB-01
GST-401
GST-200
LT-02
GST-105
GST-103
GST-300
GST-110
GST-701
GST-113
LT-01
GST-111
GST-122
GST-900
GST-100
GST-500
GST-201
GST-700
GST-118
GST-302
GST-904
GST-906
GST-502
GST-502
UNDERMOUNT
LAV. BY G.C.
H.8
4.5
GWB
8'-0"
GWB
7'-6"3'-6"8'-3 5/8"GWB
8'-11 5/8"
GWB
8'-0"EQ.EQ.1'-0"EQ.EQ.
EQ.EQ.6'-0"2'-4"1'-8"3'-8"5'-5 1/2"7'-5"6'-5"1'-0"
42"
RB-01
WC-01
WC-01
8'-0 3/8"5'-6 3/4"
PT-05
PL-04
GST-11
1
GST-100GST-90
05'-6"47" T.V.
WC-01PT-03
RB-01
LT-02
ART
DUAL MOTORIZED
ROLLER SHADE 1'-10"
GST-700
GST-401
WC-02
FEATURE WALL
RB-01SLIDING GLASS
BATHROOM
DOOR
LT-02
OPEN
RB-01
WC-01
OPEN
MIRRO SLIDING
SHELFREF.
LT-01
RB-01 WC-03
48" BACKLIT
MIRROR
WC-03
ART
G24
PT-04
WC-01
1'-6"1'-2 1/2"
PL-01 GST-701
WC-03
WC-03
T-03
RB-01
WC-03
LT-01
G18
G24
B
G18
G42
M-07
WC-03
RB-01
T-03
OPE
N
D
G18
G24
G24
H
J
2'-5 1/2"2'-5 1/2"
M-07
M-07
WC-03T-03
LT-01
OPEN
G18
H
A
1'-0"9 3/4"
C
C
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - ADA KING 01A709CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607442 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A709
1 ADA KING 01 - ARCH. PLAN
1/4" = 1'-0"A709
2 ADA KING 01 - FF & E PLAN
1/4" = 1'-0"A709
3 ADA KING 01 - RCP PLAN
1/4" = 1'-0"A709
4 ADA KING 01 - ELEC. PLAN
1/4" = 1'-0"A709
5 ADA KING 01 ELEV
1/4" = 1'-0"A709
6 ADA KING 01 ELEV
1/4" = 1'-0"A709
7 ADA KING 01 ELEV
1/4" = 1'-0"A709
8 ADA KING 01 ELEV
1/4" = 1'-0"A709
9 ADA KING 01 BATH ELEV
1/4" = 1'-0"A709
10 ADA KING 01 BATH ELEV
1/4" = 1'-0"A709
11 ADA KING 01 BATH ELEV
1/4" = 1'-0"A709
12 ADA KING 01 BATH ELEV NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS.
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
11
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
TV60"60"42"7.5
A710 7
6
5
8
A710 10
9
11
12
GR7
GR6
GR8
13'-2"
3 1/2"3 1/2"2'-10 3/4"5'-10 1/8"8"6'-2 1/4"
12'-8 3/8"3'-4 3/4"19'-2 3/4"7'-0 7/8"3'-2 1/2"16'-11 5/8"3 1/2"2'-10 3/4"9'-10 7/8"3'-0 3/8"5'-4"3'-2"1'-3 3/4"2'-2"2'-0"2'-0 1/4"VTAC ACCESS
PANEL
VTAC
1L1
1 HR
1L1
1 HR
0A
0 HR
0G
0 HR
0A
0 HR
0G
0 HR
1L1
1 HR
0A
0 HR
8"29'-9 1/4"8.9
8
1L1
1 HR
1L1
1 HR
0G2
0 HR
7.5
8.8
RF-01
RB-01
RF-01
RB-01
GST-401
GST-200
LT-02
GST-105
GST-103
GST-300
GST-110
GST-11
3LT-01
GST-11
8
GST-302
GST-502
GST-502
GST-701
8.9
GWB
8'-0"
GWB
8'-0"
GWB
10'-0"
GWB
7'-6"8'-3 5/8"1'-6"2'-4"3'-6"1'-0"EQ.EQ.
EQ.EQ.EQ.1'-6"7'-5"6'-9 1/2"6'-0"2'-4"1'-8"3'-8"1'-0"
42
"
60"
60
"
RB-01
WC-01
WC-01
5'-5 3/8"
GST-900
GST-100
GST-111
PT-05
PL-04
47" T.V.
WC-01
PT-03
RB-01
ART
LT-02
DUAL MOTORIZED
ROLLER SHADE
1'-8 5/8"1'-5 1/4"
GST-401
GST-700
WC-02
FEATURE WALL
RB-01 SLIDING GLASS
BATHROOM
DOOR
OPEN
LT-02
WC-01WC-01
OPEN
MIRROSLIDING
SHELF REF.
WC-03
LT-01
WC-03
RB-01
48" BACKLIT
MIRROR
3'-4"PT-04
WC-01
G24
ART
5'-3"1'-4 1/2"1'-4 1/2"
1'-6"
PL-01
GST-701
WC-03
WC-03T-03
RB-01
WC-03
LT-01
G18B G42
G24
1'-4"
M-07
WC-03
RB-01
T-03
WC-03
C
F
G36
E J1'-0"C
M-07
M-07 WC-03
OPEN
LT-01
T-03
E
A
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - ADA KING 02A710CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607443 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A710
1 ADA KING 02 - ARCH. PLAN
1/4" = 1'-0"A710
2 ADA KING 02 - FF & E PLAN
1/4" = 1'-0"A710
3 ADA KING 02 - RCP PLAN
1/4" = 1'-0"A710
4 ADA KING 02 - ELEC. PLAN
1/4" = 1'-0"A710
5 ADA KING 02 ELEV
1/4" = 1'-0"A710
6 ADA KING 02 ELEV
1/4" = 1'-0"A710
7 ADA KING 02 ELEV
1/4" = 1'-0"A710
8 ADA KING 02 ELEV
1/4" = 1'-0"A710
9 ADA KING 02 BATH ELEV
1/4" = 1'-0"A710
10 ADA KING 02 BATH ELEV
1/4" = 1'-0"A710
11 ADA KING 02 BATH ELEV
1/4" = 1'-0"A710
12 ADA KING 02 BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS.
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
TV
42"A7117
A711
13
A711
11
6
5
8
12
15
14
9
10
0A
0 HR
0G
0 HR
0A
0 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR
0G
0 HR
0G
0 HR
1L1
1 HR
1L1
1 HR
0A
0 HR
GR7
GR8
1'-3 7/8"
16'-0 1/4"
7'-3 3/4"3'-0"3 1/2"6'-2 7/8"6'-10"5'-0 1/4"2'-7"22'-9 1/4"4'-7 3/8"4'-9 3/8"
5 1/2"
3'-3 1/8"3'-3 1/8"4'-7 3/4"6"5'-1 1/4"9'-6"
11"
3'-1 7/8"2'-6 3/8"2'-5 5/8"11'-1 1/8"
2'-2 7/8"5°3'-3 7/8"3'-2"
1'-2 7/8"
8.9
N
8.7
0G
0 HR
0G
0 HR 8
8
7
9
8
M
RF-01
RB-01
RF-01
RB-01
LT-02
GST-200
GST-401
GST-121
GST-301 GST-120
GST-500
GST-109
GST-900
GST-201
GST-104
GST-110
GST-111
GST-701
GST-113
GST-700
GST-702
LT-01
GST-118
GST-303
GST-301
GST-303
GST-502
GST-904
GST-906
UNDERMOUNT
LAV. BY G.C.
8.9
N
8.7
GWB
8'-0"
2'-0"6'-0"2'-4"GWB
8'-11 5/8"
GWB
8'-11 5/8"GWB
8'-0"2'-6"1'-0"
EQ.EQ.EQ.EQ.EQEQ1'-1 1/8"7'-8"1'-11"RB-01
PT-03 PT-03
ART
3'-6 1/4"
1'-2 5/8"
1'-3 3/4"
DUAL ROLLER SHADE
DUAL MOTORIZED
ROLLER SHADE
GST-400
GST-11
1
GST-700
GST-401
GST-120
GST-900
47" T.V.
WC-01
RB-01
DUAL
MOTORIZED
ROLLER SHADE
GST-401
LT-02
PT-03
WC-02
FEATURE WALL
LT-02
OPEN
WC-01
WC-01
RB-01 RB-01
MIRROSLIDING
SHELF REF.
RB-01
WC-01WC-01
OPEN
OPEN
RB-01
WC-01
SLIDING GLASS
BATHROOM
DOOR
WC-01
OPEN WC-01
PT-04
RB-01
PL-01
WC-01
RB-01
ART
EQ
GST-702
5'-6"WC-03
RB-01
WC-03
48" BACKLIT
MIRROR G24
ART
EQEQ
LT-01
GST-701
T-03
WC-03
LT-01
RB-01
G24
G18
G18
G42 B
M-07 T-03
RB-01
WC-03
OPE
N
D
G18
G24
G24 1'-0"EQEQ
H
J
M-07
M-07
OPEN LT-01
T-03
WC-03
AG18
RB-01
H
C
C
10"1'-0"
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - ADA DQ 01A711CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607444 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A711
1 ADA DBL QUEEN - ARCH. PLAN
1/4" = 1'-0"A711
2 ADA DBL QUEEN - FF & E PLAN
1/4" = 1'-0"A711
3 ADA DBL QUEEN - RCP PLAN
1/4" = 1'-0"A711
4 ADA DBL QUEEN - ELEC. PLAN
1/4" = 1'-0"A711
5 ADA DQ ELEVATION
1/4" = 1'-0"A711
6 ADA DQ ELEVATION
1/4" = 1'-0"A711
7 ADA DQ ELEVATION
1/4" = 1'-0"A711
8 ADA DQ ELEVATION
1/4" = 1'-0"A711
9 ADA DQ ELEVATION
1/4" = 1'-0"A711
10 ADA DQ ELEVATION
1/4" = 1'-0"A711
11 ADA DQ ELEVATION
1/4" = 1'-0"A711
12 ADA DQ BATH ELEV
1/4" = 1'-0"A711
13 ADA DQ BATH ELEV
1/4" = 1'-0"A711
14 ADA DQ BATH ELEV
1/4" = 1'-0"A711
15 ADA DQ BATH ELEV
42"
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS.
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
1
1
4
4
4
1 07/27/2016 ADD. #1
4 06/25/2018 BULLETIN #1
8 12/26/2018 BULLETIN #5
60"TV60"42"42"60"TV60"7.5
A7125
6
7
8
A7129
10
11
12
A712 14
13
15
16
GR4
GR6
GR8
GR7
3 1/2"3 1/2"2'-11 3/4"2'-9 3/4"
3 1/2"3 1/2"2'-11 3/4"VTAC
ACCESS
PANEL
VTAC
ACCESS
PANEL
VTACVTAC
3 1/2"2'-2 3/4"3 1/2"14'-1 7/8"3 1/2"2'-11 3/4"9'-2 5/8"
3 1/2"
3'-2 1/2"
5 1/2"
4'-9 7/8"
6"
4'-7 5/8"2'-9"3'-3 1/2"1'-7 3/8"3 1/2"17'-5 1/8"8"8'-2"2'-0 1/4"5'-6"3'-2"2'-6 1/2"5'-10 1/4"7 7/8"6'-2 1/4"5 1/2"12'-8 5/8"
GR3
2'-6 1/4"2'-2"1'-1 1/2"
1L
1 HR
1L1
1 HR
1L1
1 HR1L1
1 HR
0A
0 HR
0G
0 HR
0A
0 HR
0G
0 HR
1L1
1 HR
0A
0 HR
0A
0 HR
5°
8.9
8
1L1
1 HR
0G2
0 HR
7.5
8.8
GST-700
GST-200 GST-400
GST-105
GST-103
GST-500
GST-100
GST-900
GST-111
LT-01
GST-11
3
GST-701
GST-115
GST-122
GST-202
RF-01
RB-01
RF-01
RB-01
RF-01
RB-01
GST-501
GST-207
GST-201 GST-300
LT-02
GST-703
GST-118
GST-118
GST-400
GST-502
GST-302
GST-502
GST-10
2GST-90
0
GST-904
GST-906
UNDERMOUNT
LAV. BY G.C.
8.9
GWB
8'-0"
GWB
7'-6"1'-6"1'-6"1'-2"9'-10 5/8"4'-0"9'-0 3/8"
9'-0 3/8"
GWB
8'-0"
2'-6"1'-0"EQ.EQ.EQ.EQ.1'-6"2'-4"9'-7 1/8"7'-4"2'-1"2'-2"2'-3"60"
60"
60"
60"
WC-01
RB-01
PL-04
GST-100
WC-01
GST-900
GST-111
PT-05
3'-6" 47" T.V.
RB-01
WC-01
PT-03
ART
1'-8"
DUAL
MOTORIZED
ROLLER SHADE
GST-400
GST-700
GST-100
GST-900
WC-01
RB-01
PT-04
SLIDING GLASS
BATHROOM DOOR
OPEN
ART
5'-4 3/4"
PL-01
GST-703
1/4"
3'-0"3'-0"
1/4"
OPEN
WALL CABINET
COUNTERTOP
W/ BACK
SPLASH
SINK BASE W/
PULLS
BASE CABINET
W/ PULLS
WC-01
WC-113'-0"1'-8"2'-10"WC-01
RB-01
PT-04
LT-02
8'-11 1/2"8'-0 5/8"
GST-90
0GST-10
2
PL-01
47" T.V.5'-6"WC-01
RB-01
PT-03
LT-02
DUAL MOTORIZED
ROLLER SHADE
GST-400
RB-01
WC-02
FEATURE
WALL
WC-01
WC-01
SLIDING
CLOSET
DOOR
RB-01
WC-03
RB-01
48" BACKLIT
MIRROR
ART
WC-03
WC-03
LT-01
G24
PT-04
PL-01
GST-701
WC-011'-3 1/8"
WC-03
T-03
RB-01
G18
G24
G18
G42
1'-6"1'-4"
1'-4"
LT-01
M-07
WC-03T-03
WC-03
G24
G24
H
G18
RB-01
J
1'-0"2'-5 1/2"2'-5 1/2"
D
M-07M-07 T-03
WC-03 OPEN
G18
H
A
RB-01
9 3/4"1'-0"
C
CLT-01
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED ADA ONE-BEDROOM SUITEA712CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607445 OF 4915815JUNE 24, 2016 1/4" = 1'-0"A712
1 ADA ONE BEDRM SUITE - ARCH. PLAN
1/4" = 1'-0"A712
2 ADA ONE BEDRM SUITE - FF & E PLAN
1/4" = 1'-0"A712
3 ADA ONE BR SUITE - RCP PLAN
1/4" = 1'-0"A712
4 ADA ONE BEDRM SUITE - ELEC. PLAN
1/4" = 1'-0"A712
5 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
6 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
7 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
8 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
9 ADA SUITE ELEV 9
1/4" = 1'-0"A712
10 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
11 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
12 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
13 ADA SUITE BATH ELEV
1/4" = 1'-0"A712
14 ADA ONE BR SUITE ELEV
1/4" = 1'-0"A712
15 ADA SUITE BATH ELEV
1/4" = 1'-0"A712
16 ADA SUITE BATH ELEV
NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS AND ACTUAL
PATTERNS.
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1
1
11
1
1
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
42"60"TV60"H.2
D.7
VTAC ACCESS
PANEL
VTAC
2'-7 7/8"2'-4"3'-0"2'-5 1/8"0G
0 HR
0G
0 HR
1L1
1 HR
1L1
1 HR
1L1
1 HR1L1
1 HR
0A
0 HR
0A
0 HR
0A
0 HR 0G
0 HR0G
0 HR
0G
0 HR
6'-0 1/2"5 3/4"6'-2 1/4"
12'-8 1/2"2'-0"2'-11"3 1/2"
A7137
6
8
5
A713
9
10
11
12
5 1/2"3'-0 1/2"5'-8 1/4"3 1/2"27'-5 3/4"5 1/2"2'-1 1/2"5'-0 1/4" CLR.
11 1/4"
4'-10 1/4"5 1/2"8"8
1L1
1 HR
0G
0 HR
H.2
D.7
RF-01
RB-01
RF-01
RB-01
GST-111
GST-701
LT-01
GST-104
GST-400
GST-110
GST-101
GST-201
GST-109
GST-900
LT-02
GST-301
GST-112
GST-500
GST-118
GST-303
GST-301
GST-303
M-05
GST-502
GST-106
UNDERMOUNT
LAV. BY G.C.
GST-208
GST-208
GST-108
GST-____
GWB
8'-11 5/8"
GWB
8'-0"
GWB
8'-0"
GWB
7'-6"
EQ EQ
1'-3 3/4"3'-6"2'-4"11'-2"8'-6"6'-8"4'-6 1/4"4'-3 1/2"1'-0"2'-6"2'-0"1'-6"MIRROR
47"
T.V.
SHEL
F
SLIDING DOOR
REFER TO RCP8'-0"WC-01
WC-01
RB-01
GST-111
GST-101GST-900
GST-208
GST-____CUBOARD, NO REF HERE
WC-01
PT-03
RB-01
LT-02
DUAL ROLLER
SHADE
GST-400
WC-02
FEATURE WALL
RB-01GLASS
PANEL
BEHIND
SLIDING GLASS
DOOR
LT-02
OPEN
MIRROR
SLIDING
DOOR
SHEL
FREF.
WC-01
RB-01
WC-01
WC-03
RB-01
WC-03
48" BACKLIT
MIRROR
OPEN
LT-01
WC-03
T-03
RB-01
LT-01
RB-01
GST-701
M-07
1'-0"4'-0"AR
T
4'-3"1'-4"4'-9"T-03WC-03
WC-03
PT-04
PL-01
WC-01
M-07
1'-6"
1'-2"
RB-01
STATIONARY
GLASS
PANEL
LT-01
OPEN
T-03
M-07
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333ENLARGED GUESTROOM - DQ SUITEA713CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607446 OF 4915815JUNE 24, 2016NOTE:
REFER TO CAMBRIA
STANDARDS FOR FINISH
SELECTIONS
1/4" = 1'-0"A713
1 DBL QUEEN SUITE - ARCH. PLAN
1/4" = 1'-0"A713
2 DBL QUEEN SUITE - FF & E PLAN
1/4" = 1'-0"A713
3 DBL QUEEN SUITE - RCP PLAN
1/4" = 1'-0"A713
4 DBL QUEEN SUITE - ELEC. PLAN
1/4" = 1'-0"A713
5 DQ SUITE ELEVATION
1/4" = 1'-0"A713
6 DQ SUITE ELEVATION
1/4" = 1'-0"A713
7 DQ SUITE ELEVATION
1/4" = 1'-0"A713
8 DQ SUITE ELEVATION
1/4" = 1'-0"A713
9 DQ SUITE BATH ELEV
1/4" = 1'-0"A713
10 DQ SUITE BATH ELEV
1/4" = 1'-0"A713
11 DQ SUITE BATH ELEV
1/4" = 1'-0"A713
12 DQ SUITE BATH ELEV
NOTE:
COORDINATE WITH
ELECTRICAL
DRAWINGS
1 ENTIRE SHEET
1 07/27/2016 ADD. #1
8 12/26/2018 BULLETIN #5
1'-10"2"4'-0"2'-0"1'-10"2"5'-0"7'-0"6'-0"W1RG-1G-1G-1G-1FLOOR LEVEL1'-10"2"5'-0"2'-0"7'-0"1'-10"2"5'-0"7'-0"W2R6'-0"3'-0"3'-0"W3W152'-5 3/4"2 1/4"7'-10"1'-6"10'-6"2 1/4"6'-8"2 1/4"4'-7 1/4"2 1/4"6'-8"6"19'-0"G-1G-1G-1G-1G-1G-1G-1G-1G-1W1L7'-0"5'-0"2"1'-10"6'-0"1'-10"2"4'-0"2'-0"G-1G-1G-1G-11'-10"2"5'-0"2'-0"7'-0"7'-0"5'-0"2"1'-10"W2L2 1/4"3'-6 1/4"2 1/4"7'-2"2 1/4"3'-2"2 1/4"7'-2"2 1/4"3'-2"2 1/4"7'-2"2 1/4"1'-0"32'-8"2 1/4"6'-8"2 1/4"4'-7 1/4"2 1/4"6'-8"6"19'-0"G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1SP-1SP-1SP-1SP-1SP-1SP-1SP-1SP-1SP-1W5W2R.1W2L.1SP-1SP-1SP-1SP-1SP-1SP-1SP-1SP-11'-10"2"5'-0"2'-0"7'-0"1'-10"2"5'-0"7'-0"1'-10"2"5'-0"2'-0"7'-0"5'-0"2"1'-10"7'-0"3rd Flr.2nd Flr.2'-11 5/8"9'-1 5/8"10'-9 3/8"10'-9 3/8"4th Flr.TrussBearing1'-0"1'-0"1'-0"W6FLOOR LEVEL8'-1"1'-1"14'-0"1'-0"2"6'-11"3'-10"2"6'-0"2"3'-10"G-2G-1G-1G-2W710'-0"9'-2"1'-10"2"8'-0"6'-4"G-1W87'-2"1'-0"1'-10"2"5'-2"8'-2"2'-9"2"2'-9"5'-8"G-1G-1G-1G-1W91'-10"2"5'-2"7'-2"1'-0"1'-10"2"4'-10"2"2'-7"2"2'-7"2"4'-10"2"1'-10"19'-4"G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1G-1W108'-11"1'-1"1'-10"2"6'-11"3'-10"2"6'-0"2"3'-10"14'-0"G-1G-1G-1G-2G-2G-1NOT USEDIW18'-0"2'-4"G-6FLOOR LEVEL1'-10 1/2"1 1/2"6'-10 1/2"1 1/2"1'-0"10'-0"3'-1 1/2"1 1/2"3'-2"1 1/2"3'-1 1/2"9'-8"G-5G-5G-5G-5G-4G-4G-4IW2IW31'-10 1/4"1 1/2"6'-10 3/4"1 1/2"1'-0"10'-0"3'-6 1/4"1 1/2"3'-3"4 1/2"3'-4 3/4"10'-8"G-5G-5G-5G-5G-5G-5G-4G-4G-41'-10 1/4"1 1/2"6'-10 3/4"1 1/2"1'-0"10'-0"4 1/2"2'-11 5/8"1 1/2"2'-11 5/8"1 1/2"2'-11 5/8"1 1/2"2'-11 5/8"1 1/2"3'-1 1/8"15'-5 3/4"IW4G-5G-5G-5G-5G-5G-5G-5G-5G-5G-5G-4G-4G-4G-4G-48'-1 1/2"2'-10 1/2"1 1/2"6'-0"1 1/2"2'-10 1/2"12'-0"WI5G-5G-5G-1G-2G-3G-4G-5G-6GLAZING SCHEDULE1/4" THICK FIRE-PROTECTIVE SAFETY CLEAR GLAZING1" THICK INSULATED TEMPERED CLEAR GLASSSP-11" THICK INSULATED TEMPERED SPANDREL GLAZING PANEL- CLEAR GLASS. PAINT INTERIOR FACE BLACK1" THICK INSULATED CLEAR GLASS1/4" THICK TEMPERED CLEAR GLASS3/8" THICK TEMPERED GLASS WITH CERAMIC FRITSIMULATED SANDBLAST EFFECT - 55% VISIBLETRANSMITTANCE1/4" THICK CLEAR GLASSG-71/2" THICK TEMPERED CLEAR GLASSG-2G-2G-2G-2G-2G-2G-2G-2G-1G-1G-1G-1G-1FLOOR LEVEL10'-0"1'-10"2"6'-10"2"1'-0"20'-4"2'-1"2"6'-3"2"3'-0"2"6'-3"2"2'-1"W11W12G-2G-28'-2"7'-1"1'-1"10'-0"1'-10"2"6'-0"2"1'-10"W13R7'-2"1'-0"1'-10"2"5'-2"7'-0"5'-0"2"1'-10"G-2G-2G-1G-1W13LG-2G-1G-2G-17'-2"1'-0"1'-10"2"5'-2"7'-0"1'-10"2"5'-0"W15G-2G-2G-1G-112'-1 3/4"6"6'-8"2 1/4"4'-7 1/4"2 1/4"10'-6"1'-6"2'-5 3/4"2 1/4"7'-10"W162nd Flr.2 1/4"3'-6 1/4"2 1/4"7'-2"2 1/4"3'-2"2 1/4"7'-2"2 1/4"3'-2"2 1/4"7'-2"2 1/4"1'-0"32'-8"1'-0"3rd Flr.4th Flr.TrussBearing32'-8"6"6'-8"2 1/4"4'-7 3/8"2 1/4"12'-1 7/8"G-1G-1G-1G-1G-1G-1SP-1SP-1SP-1SP-1SP-1SP-16'-0"2'-0"1'-10"2"4'-0"5'-2"W14G-2G-12'-11 5/8"9'-1 5/8"10'-9 3/8"10'-9 3/8"REVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333WINDOW TYPESA800CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607447 OF 4815815JUNE 24, 2016 1/4" = 1'-0"A8001WINDOW TYPES 1/4" = 1'-0"A8002WINDOW TYPES 1/4" = 1'-0"A8003INTERIOR WINDOW TYPES 1/4" = 1'-0"A8004WINDOW TYPES
SEE SCHD.SEE SCHD.
TYPE ATYPE B SEE SCHD.SEE SCHD.
EQ EQ
TYPE C
12'-0"8"7'-0"6"6"6"10"SEE SCHD.SEE SCHD.
GLAZING
TYPE DSEE SCHD.3'-6"6"6"6"
SEE SCHD.
TYPE E
3 1/2"3 1/2"
SEE SCHD.10"3 1/2"SEE SCHD.GLAZINGGLAZING
3'-0"2'-0"
5'-0"SEE SCHD.FRAMELESS
GLASS
SLIDING
DOOR
SEE SCHD.SEE SCHD.TYPE FTYPE GTYPE H
SEE SCHD.SEE SCHD.TYPE JTYPE K1'-2"4'-5"SEE SCHD.SEE SCHD.
9"4"
GLAZING
TYPE L
2"2"2"4"2"2"
TYPE 1 TYPE 2
VARIES
VARIESVARIES
VARIES1 3/4"1 3/4"1 3/4"
TYPE 3
VARIES
VARIESSLIDING FRAMELESS
GLASS DOOR
DOOR HEADER
ABOVE
NOTE: MAINTAIN 32" MIN. CLEAR BETWEEN OUTSIDE FACE
OF DOOR JAMB AND EDGE OF DOOR IN FULLY OPENED
POSITION.
BATHROOM SIDE
FOYER SIDE
DOUBLE
WOOD STUDS
FLOOR BASE BELOW
AS SCHED.PARTITIONFLOOR MOUNTED
DOOR GUIDE BELOW
TRANSLUCENT
VINYL BULB SEAL
DOOR PULL
AS SCHED.
DOUBLE
WOOD STUDS
EXTENT OF
SLIDING DOOR
TRACK ABOVE
3/4"
FIXED FRAMELESS
GLAZING SYSTEM
PANEL
OVERLAP OF DOOR IN
CLOSED POSITION
5/8" TYPE "X" GYPSUM
BOARD
2X4 WD CEILING
FRAMING
PROVIDE BLOCKING
(ENTIRE LENGTH OF
BATHROOM WALL) AS
REQUIRED FOR DOOR
TRACK & WINDOW
FRAME
CLG-MOUNTED
DOOR TRACK
DOOR VALANCE BY
DOOR
MANUFACTURER
SLIDING GLASS DOOR
SLIDING DOOR
CARRIAGE
WALL JAMB
BEYOND
5/8"
FRAMELESS
GLAZING
SYSTEM
1 5/8"
REVISIONS
PROJECT #:DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333DOOR SCHEDULEA900CAMBRIA SUITES HOTEL1000 LONGLEAF LANE,SOUTH WINDSOR, CT 0607448 OF 4915815JUNE 24, 2016D O O R S C H E D U L E
Tag
No.Location
Rm.
No.
Typ
e
Door Frame
Fire
Rating
Hdware
Set
Card
Reader Remarks
Size
Mat'l Finish Glazing Mat'l Finish TypeWidth Height Thickness
001 VESTIBULE 001 C 12'-0" 7'-8" 2" ALUM/GL ANOD G-7 ALUM ANOD - - 01 No
002 VESTIBULE 001 C 12'-0" 7'-8" 2" ALUM/GL ANOD G-7 ALUM ANOD - - 01 Yes REMOTE CARD READER
004 WORK AREA 029 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 45 MIN 02 No PROVIDE KICKPLATE, SEE
HARDWARE
008 A WOMEN TLT 008 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 - 03 No
008 B WOMEN TLT 008 L 3'-0" 6'-6" 1 3/4" WD PAINT HM Paint 1 - 04 No PROVIDE KICKPLATE, SEE
HARDWARE
008 C WOMEN TLT 008 L 2'-4" 6'-6" 1 3/4" WD PAINT HM Paint 1 - 05 No
008 D WOMEN TLT 008 L 2'-4" 6'-6" 1 3/4" WD PAINT HM Paint 1 - 05 No
008 E WOMEN TLT 008 L 2'-4" 6'-6" 1 3/4" WD PAINT HM Paint 1 - 05 No
009 A MEN TLT 009 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 - 03 No PROVIDE KICKPLATE, SEE
HARDWARE
009 B MEN TLT 009 L 3'-0" 6'-6" 1 3/4" WD PAINT HM Paint 1 - 04 No
010 COFFEE HOUSE PUB 010 F 6'-0" 8'-0" 1 3/4" ALUM/GL ANOD G-5 ALUM ANOD ALUM - 06 Yes
011 PREFUNCTION 011 F 6'-0" 8'-0" 1 3/4" ALUM/GL ANOD G-5 ALUM ANOD ALUM - 08 Yes REMOTE OPENER ON EXTERIOR
012 A MEETING ROOM 012 B 6'-0" 7'-0" 1 3/4" WD/GL STAIN - HM Paint 1 45 MIN 07 No KICKPLATE & VIEWERS, SEE
HARDWARE
012 B MEETING ROOM 012 B 6'-0" 7'-0" 1 3/4" WD/GL STAIN - HM Paint 1 45 MIN 07 No KICKPLATE & VIEWERS, SEE
HARDWARE
012 C MEETING ROOM 012 F 6'-0" 8'-0" 1 3/4" ALUM/GL ANOD G-5 ALUM ANOD SEE RMKS - 06 No SEE WINDOW TYPES FOR FRAME
012 D MEETING ROOM 012 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 45 MIN 09 No
012 E MEETING ROOM 012 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 45 MIN 09 No
012 F MEETING ROOM 012 B 6'-0" 7'-0" 1 3/4" WD STAIN - HM Paint 1 45 MIN 07 No
013 A KITCHEN 013 K 3'-0" 7'-0" 1 1/2" Poly Core HPL - HM Paint 1 - 56 No
013 B KITCHEN 013 K 3'-0" 7'-0" 1 1/2" Poly Core HPL - HM Paint 1 45 MIN 11 No
015 FUNCTION STOR. 015 B 6'-0" 7'-0" 1 3/4" HM PAINT - HM Paint 1 45 MIN 12 No
016 A PREFUNCTION 011 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 45 MIN 13 No HALF SS PANEL ON PUSH SIDE
016 B BOH CORRIDOR 016 E 3'-6" 7'-0" 1 3/4" HM PAINT G-5 HM Paint 1 - 14 Yes
016 C BOH CORRIDOR 016 A 3'-0" 8'-0" 1 3/4" HM PAINT - HM PAINT 1 - 15 No
017 BREAK RM 017 E 3'-0" 7'-0" 1 3/4" HM/GL PAINT G-5 HM Paint 1 45 MIN 16 No
019 EMP. TLT 019 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 - 17 No
020 BEV. STOR. 020 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 45 MIN 18 No
022 ENG. OFFICE 022 K 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 45 MIN 19 No
023 A MECH. RM 023 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 45 MIN 20 No
023 B MECH. RM 023 B 6'-0" 7'-0" 1 3/4" HM PAINT - HM Paint 1 - 21 No
024 LAUNDRY OFFICE 024 E 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 - 22 No
025 A LAUNDRY 025 G 5'-0" 7'-0" 1 3/4" HM PAINT - HM Paint 1 - 23 No
025 B LAUNDRY 025 A 3'-6" 7'-0" 1 3/4" HM PAINT - HM Paint 1 - 24 No
026 LINEN STOR. 026 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 -25 No
028 ELEC. 028 A 6'-0" 7'-0" 1 3/4" HM PAINT - HM Paint 1 45 MIN 27 No
029 A WORK AREA 029 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 45 MIN 28 No PROVIDE KICKPLATE, SEE
HARDWARE
031 OFFICE 031 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 - 29 No PROVIDE KICKPLATE, SEE
HARDWARE
032 OFFICE 032 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 - 29 No PROVIDE KICKPLATE, SEE
HARDWARE
033 IT ROOM 033 B 3'-0" 7'-0" 1 3/4" WD PLAM - HM PAINT 1 - 30 No PROVIDE KICKPLATE, SEE
HARDWARE
034 DOS OFFICE 034 A 3'-0" 7'-0" 1 3/4" WD STAIN - HM PAINT 1 45 MIN 29 No PROVIDE KICKPLATE, SEE
HARDWARE
035 ELEV. EQ. RM 035 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 90 MIN 31 No
036 A GUEST LAUNDRY 036 E 3'-0" 7'-0" 1 3/4" WD/GL STAIN G-3 HM Paint 1 45 MIN 32 Yes ONITY CARD LOCK, KICKPLATE
036 B GUEST LAUNDRY 036 E 3'-0" 7'-0" 1 3/4" WD/GL STAIN G-3 HM Paint 1 - 33 Yes ONITY CARD LOCK, KICKPLATE
037 CORRIDOR 037 E 3'-0" 7'-0" 1 3/4" WD/GL STAIN G-3 HM Paint 1 45 MIN 34 No
038 STORAGE 038 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 45 MIN 20 No ONITY CARD LOCK, KICKPLATE
039 FITNESS CENTER 039 F 3'-0" 7'-0" 1 3/4" ALUM/GL PAINT G-5 ALUM ANOD 3 - 36 Yes
040 A INDOOR SWIMMING POOL 040 F 3'-0" 8'-0" 1 3/4" ALUM/GL ANOD G-5 ALUM ANOD SEE RMKS - 37 Yes SEE WINDOW TYPES FOR FRAME
040 B INDOOR SWIMMING POOL 040 F 3'-0" 8'-0" 1 3/4" ALUM/GL ANOD G-5 ALUM ANOD SEE RMKS - 37 Yes SEE WINDOW TYPES FOR FRAME
040 C INDOOR SWIMMING POOL 040 F 6'-0" 8'-0" 1 3/4" ALUM/GL ANOD G-5 ALUM ANOD SEE RMKS - 38 Yes SEE WINDOW TYPES FOR FRAME
041 POOL EQPM RM 041 A 3'-0" 7'-0" 1 3/4" HM PAINT HM PAINT 1 45 MIN 39 No
042 POOL MECH. ROOM 042 A 3'-0" 7'-0" 1 3/4" HM PAINT HM PAINT 1 - 40 No
043 MEN'S 043 A 3'-0" 7'-0" 1 3/4" HM PAINT HM PAINT 1 - 35 No
044 WOMEN'S 044 A 3'-0" 7'-0" 1 3/4" HM PAINT HM PAINT 1 - 35 No
151 A CORRIDOR 151 A 3'-0" 7'-0" 1 3/4" WD STAIN HM PAINT 1 45 MIN 41 No
151 B CORRIDOR 151 F 3'-0" 7'-0" 1 3/4" ALUM/GL ANOD G-5 ALUM ANOD 3 - 42 Yes
152 A STAIR A 152 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 2 90 MIN 43 No PROVIDE KICKPLATE, SEE
HARDWARE
152 B STAIR A 152 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 2 - 44 No
153 A STAIR B 153 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 2 - 45 Yes
153 B STAIR B 153 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 2 90 MIN 10 No
219 ELEVATOR LOBBY 217 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 46 Yes ONITY CARD LOCK
223 VENDING 221 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 48 No
225 ELEC. 225 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 45 MIN 20 No
242 LINEN CHUTE 242 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 47 Yes ONITY CARD LOCK, HALF SS PANEL
ON PUSH SIDE
252 STAIR A 252 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 2 90 MIN 43 No PROVIDE KICKPLATE, SEE
HARDWARE
253 STAIR B 253 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 2 90 MIN 43 No PROVIDE KICKPLATE, SEE
HARDWARE
319 ELEVATOR LOBBY 317 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 46 Yes ONITY CARD LOCK
323 TELE/DATA 323 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 48 No
325 ELEC. 325 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 45 MIN 20 No
340 LINEN CHUTE 340 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 47 Yes ONITY CARD LOCK, HALF SS PANEL
ON PUSH SIDE
352 STAIR A 352 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 90 MIN 43 No PROVIDE KICKPLATE, SEE
HARDWARE
353 STAIR B 353 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 2 90 MIN 43 No PROVIDE KICKPLATE, SEE
HARDWARE
419 ELEVATOR LOBBY 417 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 46 Yes ONITY CARD LOCK
423 TELE/ DATA 423 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 48 No
425 ELEC. 425 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 45 MIN 20 No
442 LINEN CHUTE 442 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 1 20 MIN 47 Yes ONITY CARD LOCK, HALF SS PANEL
ON PUSH SIDE
452 STAIR A 452 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 90 MIN 43 No PROVIDE KICKPLATE, SEE
HARDWARE
453 STAIR B 453 A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 2 90 MIN 43 No PROVIDE KICKPLATE, SEE
HARDWARE
500 A STORAGE GARAGE 500 A 3'-0" 7'-0" 1 3/4" HM PAINT - HM PAINT 2 - - No
1/4" = 1'-0"A900
1 Door Types
1/4" = 1'-0"A900
2 Door Frame Types
G U E S T R O O M D O O R S C H E D U L E
Tag Guestroom Door Location
Door Frame
Fire
Rating
Hdware
Set
Card
Reader RemarksType
Size
Mat'l Finish Glazing Mat'l Finish
Frame
TypeWidth Height Thickness
GR1 GUESTROOM ENTRY A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 20 MIN 34 Yes ONITY CARD LOCK
GR2 GUESTROOM BATH (SLIDING) H 3'-2" 8'-0" GL GL G-6 MET ANOD - - 36 No
GR3 GUESTROOM CLOSET (SLIDING) J 3'-0" 7'-0" 1 3/4" SCWD PLAM - MET PAINT - - 36 No
GR4 GUESTROOM BEDROOM A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 - 33 No
GR5 GUESTROOM CLOSET A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 - 33 No
GR6 CONNECTOR A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 45 MIN 35 No DOOR INSTALLED IN PAIRS
GR7 ADA GUESTROOM ENTRY A 3'-0" 7'-0" 1 3/4" SCWD PLAM - HM PAINT 1 20 MIN 34 Yes ONITY CARD LOCK
GR8 ADA GUESTROOM BATH (SLIDING) H 3'-2" 8'-0" 1/2" GL GL G5 MET ANOD - - 36 No
NOTES:
1. ALL EXTERIOR ALUMINUM DOORS & FRAMES SHALL HAVE A CLEAR ANODIC COATING FINISH.
2. ALL EXTERIOR HM DOORS & FRAMES SHALL BE PAINTED TO MATCH A CLEAR ANODIC FINISH COLOR.
3. SEE INTERIOR FINISH PLANS, ELEVATIONS AND SPECIFICATION FOR ALL INTERIOR DOOR & FRAME FINISHES.
4. ALL EXTERIOR READERS REQUIRE A 4"x4" BOX TO MOUNT TO, TYPICAL. ELECTRICAL MUST BE IN THE CEILING FOR A CONNECTION TO CONTROL BOX AND
ELECTRIC STRIKE, COORDIANTE WITH LOW VOLTAGE CONTRACTOR.
3" = 1'-0"A900
3 DETAIL - GUESTROOM BATHROOM JAMB
3" = 1'-0"A900
4 DETAIL - GUESTROOM BATHROOM HEAD
2
2
2
2
2
2
6
6
2 08/09/2016 ADD. #2
6 11/05/2018 BULLETIN #3
102101100100106105103104J546K.8MK.24.512224567891010.110.211121314161718201918.1202221202323.12424.124.225252525252626.1272727282826.328.12930313233343535.229.13623.236.536.336.43737383940414243444545.1464747.148505152535454.154.25555.157595958.1616264206365666735.118x4218x4218x4218x4218x4218x6018x7218x72 18x7218x3618x4822REVISIONSPROJECT #: DATE:phonefaxmpg-architects.com330.666.5770330.666.88123660 Embassy ParkwayFairlawn, OH 44333KITCHEN EQUIPMENT PLAN & DETAILSA950CAMBRIA SUITES HOTEL1000 TOWN SQUARE, SOUTHWINDSOR, CT 0607449 OF 4915815JUNE 24, 2016KITCHEN EQUIPMENT SCHEDULEITEMNO.Count DESCRIPTION46 2 CHEMICAL SHELF ABOVE MOP SINK (PART OF #47)47 2 MOP SINK STORAGE CABINET47.1 2 MOP SINK FAUCET (PART OF #47)48 2 MOP RAQCK (PART OF #47)50 2 CLEAN DISHTABLE WITH SINKS51 2 DOLLY, FOUR WHEEL (SMALLWARES)52 2 WAREWASHER, DOOR TYPE, HIGH TEMP53 2 CONDENSATE HOOD54 2 SOILED DISHTABLE54.1 2 PRE-RINSE FAUCET, WALL MOUNT54.2 2 TABLE MOUNTED DOUBLE SIDED RACK SHELF55 2 WORK TABLE55.1 2 WALL SHELVES57 2 SINK, SOAK58.1 2 SPLASH MOUNT FAUCET59 4 TWO TIER WALL SHELVING61 2 POT/PAN SHELVING62 2 UNDERCOUNTER REFRIGERATOR63 2 UNDERBAR HANDSINK64 2 KNOCK BOX (BY OTHER)65 2 CAN OPENER66 2 POT RACK, HOOD MOUNTED67 2 UNDER COUNTER HEATED CABINET100 2 COFFEE BREWER101 1 COFFEE STATION (BY OTHER)102 1 COFFEE STATION WALL SHELF (BY OTHER)103 1 MICROWAVE OVEN104 1 DISPLAY CASE, FROZEN105 1 COMBO NON-REFRIGERATED/REFRIGERATEDSERVICE CASE106 1 DISPOSABLE CUP DISPENSERSKITCHEN EQUIPMENT SCHEDULEITEMNO.Count DESCRIPTION26 2 COMBINATION WALK-IN COOLER-FREEZER26.1 2 WALK-IN COOLER COIL26.3 2 WALK-IN FREEZER COIL27 6 WALK-IN COOLER SHELVING, 74" POSTS, 6 TIER,EPOXY28 4 WALK-IN COOLER SHELVING, 74" POSTTS, 6 TIER,EPOXY28.1 2 FREEZER DUNNAGE RACK, 3'29 2 WORK TABLE29.1 2 WALL SHELF30 2 COUNTER MIXER31 2 FOOD PROCESSOR32 2 REFRIGERATOR/FREEZER, DUAL-TEMP33 2 LANDING TABLE34 2 FRYER, DEEP FAT, GAS35 2 6 BURNER RANGE WITH OVEN35.1 2 48" GRIDDLE TOP RANGE WITH OVEN, GAS35.2 2 WALL SHELVES WITH 4" OFFSET FOR AIR GAP36 2 EXHAUST HOOD36.3 2 HOOD CONTROLS36.4 2 SS WALL FLASHING36.5 2 FIRE SUPPRESSION SYSTEM37 4 MOBILE PAN RACK38 2 TOASTER, SLOT-TYPE39 2 CHEF'S COUNTER, 29" X 34" D40 2 REFRIGERATOR, SANDWICH/SALAD PREP41 2 REFRIGERATOR, SANDWICH/SALAD PREP42 2 COUNTER WITH HAND SINK, 23" X 43" D43 2 MICROWAVE OVEN44 2 WAITRESS PICKUP COUNTER, 14'-7" L X 24" D45 2 SERVING SHELF45.1 2 OVERHEAD FOOD WARMER (BOTTOM UNIT WITHLIGHTS)KITCHEN EQUIPMENT SCHEDULEITEMNO.Count DESCRIPTION1 2 GLASS CHILLER, 36"2 6 POS (BY OWNER)4 2 UNDERBAR DUMP SINK5 2 GLASSWASHER6 2 BAG-N-BOX7 2 CO2 TANK (BY OTHER)8 2 STORAGE CABINET (BY OTHER)9 2 UNDERBAR COCKTAIL STATION 6'-0"10 2 ISLAND KEG COOLER10.1 2 DISPENSING HEAD, DRAFT BEER, 3 SPIGOTS10.2 2 ISLAND BAR (BY OTHER)11 2 ESPRESSO MACHINE (BY OTHER)12 2 BACK BAR (BY OTHER)13 2 BACK BAR REFRIGERATOR14 2 BACK BAR REFRIGERATOR16 2 ICED TEA BREWER (BY OTHER)17 218 2 BEVERAGE COUNTER18.1 2 DROP-IN SINK WITH FAUCET19 2 BEVERAGE COUNTER WALL SHELVES20 8 TRASH RECEPTACLE21 2 FIRST AID STATION (BY OTHER)22 3 HAND SINK WITH FAUCET23 2 ICE MAKER23.1 2 BIN. ICE23.2 2 ICE MACHINE FILTER SYSTEM24 2 PREP TABLE WITH SINKS24.1 2 FAUCET, DECK MOUNT24.2 2 TWO TIER WALL SHELVING25 10 STORAGE SHELVING, 74" POSTS, 6 TIER, EPOXY 3/8" = 1'-0"A9504GETCETRA MARKET 3/8" = 1'-0"A9501ENLARGED KITCHEN EQUIPMENT PLAN1NEW SHEET1 7/27/2016 ADD. #12 8/9/2016 ADD. #222