HomeMy WebLinkAbout1973-4-18 - 194 Carriage Drive - Septic ApplicationUlown of OoW4 Mubsor
Department of Pollution Control
SOUTH WINDSOR, CONNECTICUT
DRAIN LAYER'S PERMIT
Application for Permit to Install or Repair Individual Sewage Disposal System
Fee Paid $..... ...... 2Q..QQ..... By O..wxer....ta....uildimg...Aeperi+tizGa.t.......()3.-.27.-.7.3..... Permit No . ................... .7..3.-.1.9......................
Date ................ 1.$....AP-ri ,.,.....1.97.3........
Pursuant to written application, permission is hereby granted to the Licensed Drain Layer named herein
for repair ......... or construction .--X.. of an individual sewage disposal system concerning which the following
information is submitted:
1. Owner of Property ........... MPJM.:................_....._..................._................ Address of Owner .... ....... ........... ._._.- .......... :.......:....... ..
.... .. ..........................
2. Location of Property .J.. ......... Darra.age.:..Dxi.v,e,..,.::.- ................... ...... ............................... :.:.,:::...::...... :::...;.,....w::.:...::;: Lot No. .........1A...............
3. Type of Structure .. .......... ...Dwelli.xg-.................................. ............... ............. ................................................ ............. ......................................................................................
(Dwelling, Commercial Building, Store, etc.)
4. Number of Families or Persons to Occupy Premises ........... O.xe.....(J.).... family ..................................................................................................
5. Number of Bedrooms ....Thre.e... (3).............
6. Average Daily Flow ................ ...............................
Manufacturer and
7. Liquid Capacity of Septic Tank............__1..*OOO...ga1l.oaMaterial of Septic Tank Arrow - coxcrete
8. Soil Conditions: Type of Soil..............................w....._................... -.- ............ -...._........................_..........................,,................_...................w....
(Sand, Gravel, Clay, etc.)
Maximum ground water table ....................... ........ ................... ....... ................ ............................
..........
9. If not served by public water supply:
Distance from Owner's well ... Publ, c...............................................
From adjacent wells ............................ ........ ......................
........._............
10. Distance to nearest water course, drainage ditch, storm drain or embankment ....2.5 f.t...............................................................
11. Percolation Tests: Time for 1" drop in soil test ........Two ..... (.2.).... mixut.................................................................................................................
Classificationof soil .............:......:..:........:....... ................... ......... ............. ....... ................................... .-.......:::.....:.:....,.....,....................................
12. Minimum square feet of effective seepage area required 1.2-5aq...-ft....p.e.r...b.o.�drnopl.......tot.e.1....0f....3...3.....e1q...ft.
13. Leaching System: Number of trenches ..........TY.0 ..(.2.).............. Length ........... 1.3.Q....f.t.......... ......... Width ...........3.,,.o .ft..................
Total ....39.0 sq.. ft..:........ Other ....... .... ....... •...... .... ..... ..............,........,..........................................,.......... ........... ............
................
14. Plot Plan Attached. Yes,, r ...... .................
15. Layout Approved. Yes .................................... ►*
16. This permit expires .........1.8.June*.1.97.3 .............................. NOTE: Cast iron xot installed at time of inspe 'on
Signature ............. ..........._.........................
..........................
R.P. P xx, J { i ed Drain Layer) W9-206363
Installation Completed, Inspected and Approved in accordance with St, to Public Health Code and Local Ordinances
?5.....April........................ 19.... I ..73. By ......-...r?clvix....Edw�+.rda, Jr............................................................
PollutionProblem abated Date .-,-:::..::::::...::........::.......::......w ,.,.......... ......... ....... ................................... ................. .... ..........................
Inspector
I
ff i
10
1,--
3 C
` I
,
f
w
NOTES SOUTH WINDSOR POLLUTION CONTROL
Scale: 1" = 40' LOCATION Carriage Drive (Lot 11)
S T D/B OWNER Linmax
A 31 TYPE OF WORK Se tic Field Ixstallatiox
B 33 29 DATE o4-25- 3 PERMIT 3-1PIPE41, O.B.
INSTALLER Pi in W - 063Lz,
INSPECTOR ME DRAWN BY ME
CONNECT/CUT L /GHr B POWER COMPANY
Lor /o
4� L!11EAL FEET Jr 1 iLL PLR
BEDROU'V 1 H10 11'! =T VIIDE
GRAVEL OR BF;O,;i=:1 61-01NE K6 A
OD-ITH OF 13 INCHES, TRENCHES
f0 3 _ S,-A '=D 12 FEET C.n.! . M:N'
�7-j-
• 7 i
is ��r�81fa�13
tj
Ry t U p Y ij1
150.00
Lor //
N
O 201 6 5600 O
ci
h
In'3 B. R. RAN CH N ,
22.0. 20. /6 /P
50' BU/LD/ NG UIVE J
/000 Go/ Septic
o�• Tank
l0 00
RP
/25.00
CARRIAGE DRIVE
SUB--) fA:`. HALLY LC f &
NO ZONING RE ULA ;:.,`;;, VIOLATEG:
-
J JAMES E. SHEEHY L.S. 7034
�C :b
Oy
PLOT PLAN FOR
L/ P M Q N
CARRIAGE DR. — SOUTH WINDSOR. COM
SCALE.' / „ = 40 ' MAR. /8, /973
✓ A M E S E. S H EE H Y L,S, 7034