Loading...
HomeMy WebLinkAbout2016-6-6 - 1 Buckland Road - Septic Approval Letter Town of South Windsor - Health Department 1540 Sullivan Avenue, South Windsor, CT 06074-2786 -CO,, Phone: 860-644-2511 ext. 250 Fax: 860-644-7280 APPROVAL TO CONSTRUCT OR REPAIR SEWAGE DISPOSAL SYSTEM Approval is hereby granted for the construction/repair of a subsurface sewage disposal system at the property described below: PROPERTY OWNER(S): One Buckland Center, LLC STREET ADDRESS: i Buckland Road TOWN:South Windsor INSTALLER: Gerald Wilcox CT.LIC# 3108 EXPIRES: 2/28/17 INSTRUCTIONS FOR INSTALLER 1. Construction plot plan submitted and approved by this office must be adhered to. 2. This office must be contacted for approval if any change is going to be made in the system location,size or design,or any changes in house,well or property line locations. 3. Any NEW sewage disposal system must conform to ALL requirements of Section 19.13-BI03 of the CT Public Health Code. I C 4. ALL new construction to be under DIRECT supervision of a CT licensed installer under Section 20-341 of the CT General Statutes. 5. The installer is RESPONSIBLE for VERIFYING LOCATIONS of PROPERTY LINES, WELLS, and BURIED UTILITY LINES prior to construction. 6. Installer to notify South Windsor Health Dept.24 hours prior to the start of construction. 7. Installer to have septic tank covers removed at the time of inspection. t SPECIFIC INSTRUCTIONS: 1. Install per approved plan,(Design Professionals, Dated 9/18/15). j 2. Licensed Installer to field stake building, well (if applicable), permanent benchmark, and septic system. Offset stakes to include bottom of trench or flow line elevations. Health Dept. staff to conduct stake inspection prior to construction of system. 3. Permanent benchmark to be set within 50 feet horizontally and 12 feet vertically of septic system. 4. Install a 2,000 gallon two-compartment septic tank, with an approved outlet filter. Risers are to be installed if there is to be more than 12"cover over septic tank cleanouts. i 5. Install 1190.2 square feet of effective leaching area, consisting of two rows 64 feet long and 72 feet long of four foot concrete galleries. System to be installed per manufacturer's specifications. Systems with total cover that exceeds ' eighteen (18)inches as measured from the top of the units to finished grade shall be vented at the distal(far)end of the system. 6. Current Sieve analysis(within 30 days)for sand fill must be submitted to the South Windsor Health Department. 7. Max depth into original grade is not to exceed one hundred(100)inches. 8. Installer to schedule, and be present for final inspection with Health Dept. staff. Level to be set up for verification of elevations OR an engineer's/surveyor's as built will be required. 9. Installer to complete and submit septic system as built plan and drawing with ties to the house. 10. Existing septic system to be properly abandoned. SIGNATURE:``1L2p 44 Oh , (Z e DATE ISSUED: 7/13/16 RENEWAL:__L_/ APPROVED BY: Heather Oatis,REHS, HHS EXPIRES: 7/13/17 EXPIRES: 1 1 THIS PERMIT IS VALID FOR A PERIOD OF ONE YEAR FROM DATE OF ISSUE. IN ACCORDANCE WITH THE CT PUBLIC HEALTH CODE SECTION 19-13-BI03e(F)(1). ONE RENEWAL IS POSSIBLE PROVIDED SOUTH WINDSOR HEALTH DEPARTMENT IS NOTIFIED PRIOR TO THE EXPIRATION DATE NOTED ABOVE. IF PERMIT EXPIRES, INSTALLERS ARE CHANGED, OR ANY OTHER DEVIATION FROM THE ORIGINAL PERMIT,A NEW APPLICATION MUST BE COMPLETED AND ALL APPLICABLE FEES MUST BE PAID. FEE PAID:$20.00 CHECK#13270 DATE PAID:6/6116