HomeMy WebLinkAbout2009-8-19 - 136 Beelzebub Road - Water Potability TestSTATE OF CONNECTICUT
DEPARTMENT OF ENVIRONMENTAL PROTECTION
dLf ,9tIM'
rRpa
August 19, 2009
Liebler Residence
136 Beelzebub Road
South Windsor, CT 06074
Dear Ms. Liebler:
Enclosed is a copy of the laboratory analysis for the unfiltered (raw) water sample collected from
136 Beelzebub Road on 7/9/2009. The water sample was analyzed for the presence of
ethylene dibromide (EDB), 1,2,3-trichloropropane (TCP), and 1,2 dibromo-3-chloropropane
(DBCP) and other pesticides.
Results from the analyses are summarized in Table 1 (attached). Table 1 also includes each
compound's respective action level set by the Connecticut Department of Public Health (DPH).
Please note that only established action levels are included in Table 1. If an action level has not
been listed it means that an action level has not been established for that particular compound
and its detection does not render the water unsafe for drinking or other domestic uses.
Referring to Table 1, the water sample collected frorn your water supply did not contain
detectable concentrations of pollutants at concentrations at or above their respective action
level. An action level is the concentration at or above which the DPH has determined there
could be a risk to the health of persons consuming the water. Consequently, your water is
considered to be potable.
The other pesticides analyzed were also reported as non detect. If you have any questions or
comments please contact me at (860) 424-3796.
Sincerely,
MaryAnne Danyluk
Environmental Analyst 2
DEP/Bureau of Water Protection and Land Reuse
Remediation Division
Enclosure(s)
Bob Devito, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
(Printed on Recycled Paper)
79 Elm Street • Hartford, CT 06106-5127
www.ct.gov/dep
An Equal Opportunity Employer
TABLE ONE
Raw Water Sample Results
136 Beelzebub Road
South Windsor, Connecticut
COMPOUND ANALYZED CONCENTRATION DETECTED ugll
1,2 dibromoethane (EDB) ND
1,2,3-trichloropropane (TCP) ND
1,2 dibromo-3-chloropropane (DBCP) ND
ACTION LEVEL ue/1
0.05
0.05
NAL
Notes: ug/l Microgram per liter
ND Not detected above analytical detection limits
NAL An action level has not been established by the Department of Public Health (DPH)
STATE OF CONNECTICUT
NR:136-1
Department of Public Health Laboratory
Clinical Testing License: CL-0197
10 Clinton St.
P.O. Box 1689
Hartford, CT 06144
Telephone (860) 509-8500
DEP - REMEDIATION
79 ELM ST.
HARTFORD CT 06106
FINAL REPORT
**
DATE ANALYZED
EPA 504.1
18023523 IA00142
132SOUTH WINDSOR
CAROLYN LIEBLER
136 BEELZEBUB
SOUTH WINDSOR CT
1
I07/09/09112:01
07/09/09107:28
07/15/09
10:00
SAMPLING POINT: OUTSIDE TAP
COLLECTOR: WING,S TITLE: EA3
PRIVATE WELL TREATMENT:
7/15/09
EPA METHOD 504.1
MEASUREMENT OF 1,2-DIBROMOETHANE (EDB), 1,2-DIBROMO-
3-CHLOROPROPANE (DBCP) AND 1,2,3 TRICHLOROPROPANE
(123TCP) IN DRINKING WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION.
------__--------------------------------------------------
Final Result: [All values expressed in ug/L (ppb)]
Compound Result
MDL
PQL
1,2-Dibromoethane ND
0.0016
0.02
1,2-Dibromo-3-Chloropropane ND
0.0021
0.02
1,2,3-Trichloropropane ND
0.0073
0.04
-o
O
C
ND = None Detected (Result Less Than The PQL)
r
0
PQL= Practical Quantitation Limit
(lowest standard)
N
w
MDL = method Detection Limit
tit
MDL calculated based on a Signal/Noise Ratio
of 5:1
r�
according to CFR Part 136 Appendix
B
** END OF REPORT **
FUKM NU. UL-bA KLV.3-UU 100
STATE OF CONNECTICUT----------
Department of Public Health Laboratory NR:136-2
-to xol�' Clinical Testing License: CL-0197
10 Clinton St.
P.O. Box 1689
Hartford, CT 06144
Telephone (860) 509-8500
DEP - REMEDIATION
79 ELM ST.
HARTFORD CT 06106
FINAL REPORT
18023526 IA00142 10 I I 11
132SOUTH WINDSOR
CAROLYN LIEBLER
136 BEELZEBUB
SOUTH WINDSOR CT
07/09/09 07/09/09 08/03/09
10:05 �12:02 �10:53
SAMPLING POINT: OUTSIDE TAP .�
COLLECTOR: SCOTT WING TITLE: EA-3 RN� ��fj'r Ade,��R
* * PESTICIDES �Qzqr��
METHOD ----------- � O
ANALYTICAL METHOD - EPA METHOD -505 I�•S�QN
ANALYSIS OF ORGANOHALIDE PESTICIDES AND
COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB)
PRODUCTS IN WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY
Date Extracted 07/15/2009
Date Analyzed 07/15/2009
RESULTS Compound Result MDL PQL
%ldrin
ND
0.007
0.03
%lachlor
ND
0.042
0.3
%trazine
ND
0.729 *
1.4
alpha Chlordane
ND
0.006
0.03
3amma Chlordane
ND
0.006
0.03
:hlordane (Technical)
ND
0.106
0.3
)ieldrin
ND
0.004
0.03
ndrin
ND
0.005
0.03
ieptachlor
ND
0.004
0.03
ieptachlor Epoxide
ND
0.004
0.03
iexachlorobenzene
ND
0.006
0.03
iexachlorocyclopentadiene
ND
0.004
0.03
�indane
ND
0.003
0.03
4ethoxychlor
ND
0.03
0.14
�is-Nonachlor
ND
0.006
0.03
Grans-Nonachlor
ND
0.007
0.03
3imazine
ND
0.481 **
1.4
Coxaphene
ND
0.224
3.0
kroclor 1016
ND
N/A
N/A
kroclor 1221
ND
N/A
N/A
%roclor 1232
ND
N/A
N/A
kroclor 1242
ND
N/A
N/A
kroclor 1248
ND
N/A
N/A
*** CONMINUED ***
FORM NO. OL-6A REV.3-00 100
STATE OF CONNECTICUT
NR:136L2
Department of Public Health Laboratory
Clinical Testing License: CL-0197
10 Clinton St.
P.O. Box 1689
Hartford, CT 06144
Telephone (860) 509-8500
DEP - REMEDIATION
79 ELM ST.
HARTFORD CT 06106
18023526 IA00142
132SOUTH WINDSOR
CAROLYN LIEBLER
136 BEELZEBUB
SOUTH WINDSOR CT
0 1 1 1 2
I07/09/09 07/09/09110:53
08/03/09
10:05 �12:02
'ry Cry•;•"ri::i >::;:;'::::.�:::y::y::,., .:::::.:>::>::
;:-: FINAL REPORT::
.,
»ti
+iLLs7471 _
ll.'- •:F r'F -
J+- JJ
roclor 1254 ND N/A N/A
roclor 1260 ND N/A N/A
utachlor ND N/A N/A
Propachlor ND 0.054 0.3
,etolachlor ND N/A N/A
etribuzin ND N/A N/A
,p'-DDE ND N/A N/A
,p'-DDD ND N/A N/A
,p'-DDT ND N/A N/A
None Detected (Result Less Than The PQL)
PQL =Practical Quantitation Limit
L =Method Detection Limit
11 values expressed in ug/L (ppb)
Values Calculated based on a Signal/Noise Ratio of 5:1
according to CFR Part 136 Appendix B
* The 2.2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0.22.
** The 2.2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0.154.
Note: The recovery of Simazine was elevated in the
calibration check standards. Any detects or non -detects
for this analyte could be considered biased high.
N
------ ** END OF REPORT **
FORM NO. OL-6A REV.3-00 100