HomeMy WebLinkAbout2010-8-4 - 136 Beelzebub Road - Water Potability TestSTATE
04;vf�
/ ,
°'t'.rEnrrn� vR°��C
August 4, 2010
Liebler Residence
136 Beelzebub Road
South Windsor, CT 06074
Dear Mr. and Mrs. Liebler:
Enclosed is a copy of the laboratory analysis for the unfiltered (raw) water sample collected from
136 Beelzebub Road on 7/15/2010. The water sample was analyzed for the presence of
ethylene dibromide (EDB), 1,2,3-trichloropropane (TCP), and 1,2 dibromo-3-chloropropane
(DBCP).
Results from the analyses are summarized in Table 1 (attached). Table 1 also includes each
compound's respective action level set by the Connecticut Department of Public Health (DPH).
Please note that only established action levels are included in Table 1. If an action level has not
been listed it means that an action level has not been established for that particular compound
and its detection does not render the water unsafe for drinking or other domestic uses.
Referring to Table 1, the water sample collected from your water supply did not contain
detectable concentrations of pollutants at concentrations at or above their respective action
level. An action level is the concentration at or above which the DPH has determined there
could be a risk to the health of persons consuming the water. Consequently, your water is
considered to be potable.
If you have any questions or comments please contact me at (860) 424-3796.
Sincerely,
MaryAnne Danyluk
Environmental Analyst 2
Remediation Division
DEP/Bureau of Water Protection and Land Reuse
Enclosure(s)
C: Sanitarian, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, Connecticut 06074
( Printed on Recycled Paper)
79 Elm Street • Hartford, CT 06106 - 5127
http://www.ct.gov/dep
An Equal Opporruniq, Employer
TABLE ONE
Raw Water Sample Results
136 Beelzebub Road
South Windsor, Connecticut
COMPOUND ANALYZED CONCENTRATION DETECTED u /l ACTION LEVEL up/l
1,2 dibromoethane (EDB) ND 0.05
1,2,3-trichloropropane (TCP) ND 0.05
1,2 dibromo-3-chloropropane (DBCP) ND NAL
Notes: ug/I Microgram per liter
ND Not detected above analytical detection limits
NAL An action level has not been established by the Department of Public Health (DPH)
STATE OF CONNECTICUT
NR:136 ``; .;��
n� Department of Public Health Laboratory
.� Clinical Testing License: CL-0197
10 Clinton St.
P.O. Box 1689
Hartford, CT 06144
Telephone (860) 509-8500
DEP - REMEDIATION
79 ELM ST.
HARTFORD CT 06106
FINAL REPORT
01**
DATE ANALYZED
EPA 504.1
18024739 IA00142 10 I 11 1
132SOUTH WINDSOR
C&C LIEBLER
136BEELZEBUB
SOUTH WINDSOR CT
07/15/10108:19
07/16/10110:42
07/21/10
12:00
SAMPLING POINT: OUTSIDE
COLLECTOR: BRIGHTWELL TITLE: INSP. AIDE
PRIVATE WELL
7/21/10
-----_---_-_------_---_--------------------------------------
EPA METHOD 504.1
MEASUREMENT OF 1,2-DIBROMOETHANE (EDB), 1,2-DIBROMO-
3-CHLOROPROPANE (DBCP) AND 1,2,3 TRICHLOROPROPANE
(123TCP) IN DRINKING WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION.
----------------------------------------------------------
Final Result: [All values expressed in ug/L (ppb)]
Compound
Result MDL
1,2-Dibromoethane ND 0.0016
1,2-Dibromo-3-Chloropropane ND 0.0021
1,2,3-Trichloropropane ND 0.0073
PQL
0.02
0.02
0.04
ND = None Detected (Result Less Than The PQL)
PQL= Practical Quantitation Limit (lowest standard)
MDL = method Detection Limit
MDL calculated based on a Signal/Noise Ratio of 5:1
according to CFR Part 136 Appendix B
4A7FR pRQTECT.IOTd AND LANW RE
UCE
REWDO-r 01V DIVIv310,v
** END OF REPORT **
FORM NO. OL-6A REV.3-00 100