Loading...
HomeMy WebLinkAbout2010-8-4 - 136 Beelzebub Road - Water Potability TestSTATE 04;vf� / , °'t'.rEnrrn� vR°��C August 4, 2010 Liebler Residence 136 Beelzebub Road South Windsor, CT 06074 Dear Mr. and Mrs. Liebler: Enclosed is a copy of the laboratory analysis for the unfiltered (raw) water sample collected from 136 Beelzebub Road on 7/15/2010. The water sample was analyzed for the presence of ethylene dibromide (EDB), 1,2,3-trichloropropane (TCP), and 1,2 dibromo-3-chloropropane (DBCP). Results from the analyses are summarized in Table 1 (attached). Table 1 also includes each compound's respective action level set by the Connecticut Department of Public Health (DPH). Please note that only established action levels are included in Table 1. If an action level has not been listed it means that an action level has not been established for that particular compound and its detection does not render the water unsafe for drinking or other domestic uses. Referring to Table 1, the water sample collected from your water supply did not contain detectable concentrations of pollutants at concentrations at or above their respective action level. An action level is the concentration at or above which the DPH has determined there could be a risk to the health of persons consuming the water. Consequently, your water is considered to be potable. If you have any questions or comments please contact me at (860) 424-3796. Sincerely, MaryAnne Danyluk Environmental Analyst 2 Remediation Division DEP/Bureau of Water Protection and Land Reuse Enclosure(s) C: Sanitarian, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, Connecticut 06074 ( Printed on Recycled Paper) 79 Elm Street • Hartford, CT 06106 - 5127 http://www.ct.gov/dep An Equal Opporruniq, Employer TABLE ONE Raw Water Sample Results 136 Beelzebub Road South Windsor, Connecticut COMPOUND ANALYZED CONCENTRATION DETECTED u /l ACTION LEVEL up/l 1,2 dibromoethane (EDB) ND 0.05 1,2,3-trichloropropane (TCP) ND 0.05 1,2 dibromo-3-chloropropane (DBCP) ND NAL Notes: ug/I Microgram per liter ND Not detected above analytical detection limits NAL An action level has not been established by the Department of Public Health (DPH) STATE OF CONNECTICUT NR:136 ``; .;�� n� Department of Public Health Laboratory .� Clinical Testing License: CL-0197 10 Clinton St. P.O. Box 1689 Hartford, CT 06144 Telephone (860) 509-8500 DEP - REMEDIATION 79 ELM ST. HARTFORD CT 06106 FINAL REPORT 01** DATE ANALYZED EPA 504.1 18024739 IA00142 10 I 11 1 132SOUTH WINDSOR C&C LIEBLER 136BEELZEBUB SOUTH WINDSOR CT 07/15/10108:19 07/16/10110:42 07/21/10 12:00 SAMPLING POINT: OUTSIDE COLLECTOR: BRIGHTWELL TITLE: INSP. AIDE PRIVATE WELL 7/21/10 -----_---_-_------_---_-------------------------------------- EPA METHOD 504.1 MEASUREMENT OF 1,2-DIBROMOETHANE (EDB), 1,2-DIBROMO- 3-CHLOROPROPANE (DBCP) AND 1,2,3 TRICHLOROPROPANE (123TCP) IN DRINKING WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION. ---------------------------------------------------------- Final Result: [All values expressed in ug/L (ppb)] Compound Result MDL 1,2-Dibromoethane ND 0.0016 1,2-Dibromo-3-Chloropropane ND 0.0021 1,2,3-Trichloropropane ND 0.0073 PQL 0.02 0.02 0.04 ND = None Detected (Result Less Than The PQL) PQL= Practical Quantitation Limit (lowest standard) MDL = method Detection Limit MDL calculated based on a Signal/Noise Ratio of 5:1 according to CFR Part 136 Appendix B 4A7FR pRQTECT.IOTd AND LANW RE UCE REWDO-r 01V DIVIv310,v ** END OF REPORT ** FORM NO. OL-6A REV.3-00 100