Loading...
HomeMy WebLinkAbout2011-11-15 - 245 Barber Hill Road - Water Potability TestPremier Laboratory, Inc 61 Louisa Viens Drive Dayville, CT 06241 Fax: 860-774-2689 Phone: 860-774-6814 Toll -Free: 800-334-0103 Report To: John Rossetti 15 Brightman Circle South Windsor, CT 06074 Copy To: a Q0V N%WG,;) 'bKE. Connecticut Department of Health Services PH-0465 Source of Sample: 245 Barber Hill Road South Windsor, CT Date of Collection: 11/15/2011 PM Date Received in Laboratory: 11/15/2011 PM Collected By: Chris Ulion / cv Laboratory ID: E111879-1 BACTERIOLOGICAL RESULTS PARAMETER RESULTS DL UNITS MCL COMMENT Total Coliforms 3 col/100ml 0 OUT Escherichia coli 0 col/100ml NE THE BACTERIOLOGICAL RESULTS ARE NOTACCEPTABLE FOR POTABILITY STANDARDS CHEMICAL RESULTS [CT GENERAL STATUTES HAVE ESTABLISHED PRIMARY MCL'S FOR THE FOLLOWING PARAMETERS] PARAMETER RESULTS DL UNITS MCL COMMENT Nitrite ND 0.010 ppm 1.0 Nitrate ND 0.10 ppm 10 Chloride 34 2.0 ppm 250 ALL OF THE ABOVE PARAMETERS MEET THE CT GENERAL STATUTES ESTABLISHED MCUS FOR POTABILITY. [CT GENERAL STATUTES HAVE NOT ESTABLISHED MCL'S FOR THE FOLLOWING PARAMETERS] PARAMETER RESULTS DL UNITS RL COMMENT pH 9.2 pH Units 6.4 to 10.0 Color 0 Color Units 15 Odor 1 Units 2 Turbidity 0.12 0.10 NTU 5 Iron ND 0.051 ppm 0.3 Manganese 0.0033 0.0020 ppm 0.05 Hardness, as CaCO3 120 0.13 ppm NE Sodium 13 1.0 ppm 28 Sulfate 46 10 ppm 250 THE ABOVE RESULTS ARL USED IN DETERMININGASPECTS OF WATER SUCH AS STAINING. ALTHOUGH NO MCUS ARE SET BY THE GENERAL STATUTE, THERE ARE RECOMMENDED LIMITS THAT ARE USED BY PUBLIC HEALTH OFFICIALS AND WATER TREATMENT SPECIALISTS IN THE INTERPRETATION OF WATER QUALITY. COMMENTS: Total Coliforms exceed the established MCL(s). This water does not meet potability standards for Bacteria. You should notify your Public Health Official for interpretation and instructions. A Water Treatment Specialist maybe consulted for possi e treatment. KEY TO TERMS COL - colonies MCL - Max Contamination Limit Till - milliliter RL - Recommended Limit ppm - parts per million ND - None Detected NTU - Turbidity unit NE - None Established AL - Action Level cv - Certified Vendor for Premier Laboratory, Inc Report is an accurate analysis of: Sample received at this laboratory III 1111111111111111111111111111111 Ills 11111 101-000000323656 Premier Laboratory, Inc Authorized Signature 11/17/2011 Page 1 of4 Premier Analytical Data Report Laboratory, Inc Connecticut Department of Health Services PH-0465 61 Louisa yens Drive Dayville, CT 06241 Fax: 860-774-2689 Phone: 860-774-6814 Source of Sample: 245 Barber Hill Road Toll -Free: 800-334-0103 Location of Sample: South Windsor, CT Date Received in Laboratory: 11/15/2011 PM Collected By: Chris Ulion / cv Laboratory ID: E111879-1 Analvte Result DL MCL RL AL COMMENT (1) 245 Barber Hill Road Date Collected: 11/1512011 Residual Chlorine ND mg/L 0.050 NE NE NE KEY TO TERMS COL - colonies MCL - Max Contamination Limit ml - milliliter RL - Recommended Limit ppm - parts per million ND - None Detected NTU - Turbidity unit NE - None Established AL -Action Level cv - Certified Vendor for Premier Laboratory, Inc III I111111111111111111111111111111111111111 101-000000323656 Page 2 or4 Premier Analytical Data Report Laboratory, Inc Connecticut Department of Health Services PH-0465 61 Louisa Viens Drive Dayville, CT 06241 Fax: 860-774-2689 Phone: 860-774-6814 Source of Sample: 245 Barber Hill Road Toll -Free: 800-334-0103 Location of Sample: South Windsor, CT Date Received in Laboratory: 11/15/2011 PM Laboratory ID: E111879-1 Collected By: Chris Ulion / cv Method: 524.2 Units: ug/L Analvte Result DL MCL COMMENT Benzene ND 0.50 5.0 Bromobenzene ND 0.50 NE Bromochloromethane ND 0.50 NE Bromodichloromethane ND 0.50 NE Bromoform ND 0.50 NE Bromomethane ND 0.50 NE n-Butylbenzene ND 0.50 NE sec-Butylbenzene ND 0.50 NE tert-Butylbenzene ND 0.50 NE Carbon tetrachloride ND 0.50 5.0 Chlorobenzene ND 0.50 100 Chloroethane ND 0.50 NE Chloroform ND 0.50 NE Chloromethane ND 0.50 NE 2-Chlorotoluene ND 0.50 NE 4-Chlorotoluene ND 0.50 NE 1,2-Dibromo-3-chloropropane (DBCP) ND 0.50 0.2 Dibromochloromethane ND 0.50 NE 1,2-Dibromoethane (EDB) ND 0.50 0.05 Dibromomethane ND 0.50 NE 1,2-Dichlorobenzene ND 0.50 600 1,3-Dichlorobenzene ND 0.50 NE 1,4-Dichlorobenzene ND 0.50 75 Dichlorodifluoromethane ND 0.50 NE 1,1-Dichloroethane ND 0.50 NE 1,2-Dichloroethane ND 0.50 5.0 1,1-Dichloroethene ND 0.50 7.0 cis-1,2-Dichloroethene ND 0.50 70 trans-1,2-Dichloroethene ND 0.50 100 1,2-Dichloropropane ND 0.50 5.0 1,3-Dichloropropane ND 0.50 NE 2,2-Dichloropropane ND 0.50 NE 1,1-Dichloropropene ND 0.50 NE cis-1,3-Dichloropropene ND 0.50 NE trans-1,3-Dichloropropene ND 0.50 NE Ethylbenzene ND 0.50 700 Hexachlorobutadiene ND 0.50 NE Isopropylbenzene ND 0.50 NE 4-Isopropyltoluene ND 0.50 NE Methyl tert-butyl ether (MTBE) ND 1.0 NE Methylene chloride ND 0.50 5.0 Naphthalene ND 0.50 NE n-Propylbenzene ND 0.50 NE KEY TO TERMS COL - colonies MCL - Max Contamination Limit ml - milliliter RL - Recommended Limit ppm - parts per million ND - None Detected NTU - Turbidity unit NE - None Established AL -Action Level cv - Certified Vendor for Premier Laboratory, Inc III 11111111111111111111111111111 11111111111 101-000000323656 Page 3 of 4 Premier Laboratory, Inc 61 Louisa Vans Drive Dayville, CT 06241 Fax: 860-774-2689 Phone: 860-774-6814 Toll -Free: 800-334-0103 Laboratory ID: E111879-1 Method: 524.2 Units: ug/L Analytical Data Report Connecticut Department of Health Services PH-0465 Source of Sample: 245 Barber Hill Road Location of Sample: South Windsor, CT Date Received in Laboratory: 11/15/2011 PM Collected By: Chris Ulion / cv Analvte Resul DL MCL Styrene ND 0.50 100 1,2,3-Tdchloropropane ND 0.50 NE 1,2,3-Trimethylbenzene ND 0.50 NE 1,1,1,2-Tetrachloroethane ND 0.50 NE 1,1,2,2-Tetrachloroethane ND 0.50 NE Tetrachloroethene (PCE) ND 0.50 5.0 Toluene ND 0.50 1000.0 1,2,3-Tdchlorobenzene ND 0.50 NE 1,2,4-Tdchlorobenzene ND 0.50 70 1,1,1-Tdchloroethane ND 0.50 200 1,1,2-Trichloroethane ND 0.50 5.0 Trichloroethene (TCE) ND 0.50 5.0 Trichlorofluoromethane ND 0.50 NE 1,2,4-Trimethylbenzene ND 0.50 NE 1,3,5-Trimethylbenzene ND 0.50 NE Vinyl chloride ND 0.50 2.0 Xylenes (total) ND 0.50 10,000 KEY TO TERMS COL - colonies MCL - Max Contamination Limit ml - milliliter RL - Recommended Limit ppm - parts per million ND - None Detected NTU - Turbidity unit NE - None Established AL -Action Level cv - Certified Vendor for Premier Laboratory, Inc COMMENT III 1111111111111111111111111111111111111111 101-000000323656 Page 4 of 4 Date: 11/14/21 :35 Premier Laboratory, LLC Taken by: Tayler Dube Rork Order#: Profile #: 47363 Name: John Rossetti Phone: 860-209-1731 Fax: Report To: John Rossetti 15 Brightman Circle South Windsor, CT 06074 Copy To: Supply Addr: 245 Barber Hill Road South Windsor, CT House Type: Color: Tan Outside Tap: Reason For Exam: C.O. Type of Supply: Well Treatment: +#one G Test Re uired Standard Profile + TRC %a ) Rent Date To Be Sampled: 11/15/2011 Contact: John Rossetti Phone: 860-209-1731 Payment: Price: $215 PIU Gheck P/ J Cash Credit Card Information Name On Card: Card #: Card Type: Expiration Date: Authorization#: 12-3 Sampled By: ),% ) 0 h Date: 00 Relinquished By: C Date: Z Received By: Date: Directions Time: / MP& Time: 1576 . Time: (5 D q 0,