Loading...
HomeMy WebLinkAboutBuilding 22 Arthur Drive (5)PERMIT # Application For 6464 6074 y DEPARTMENT DECISION Heating Permit o Cn 3E APPLICATION IS HEREBY:DEPARTMENT OF LICENSES AND INSPECTIONS o a N v APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR. 0 12/21/84 Thomas P. D' Auria 00 DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O V7 p E -d 1. LOCATION OF JOB Arthur Drive o w 0 0 NO.STREET O y LOT NO. FLOOR APT. NO. O GO63 o 2. OWNER y t. Cd o 3 O S. ADDRESS 00 3 4.YHONE a—,,D?-(9 RZ Cc C/J x S. APPLICANT C3er o f cs. ADDRESS 7.PHONE d'/ S. LICENSE NO. a G w B. EXPIRATION DATE OF LICENSE v e' C 10. ESTIMATED COST • 1 xe m 11. IS THIS A CONTRACT COST? YES O No b0 y C o 12. FEE ENCLOSED S e rm i t 13996 a dx ai is. TYPEtsJAF BUILDING:n L f RESIDENTIAL COMMERCIAL O C 14. TYPE OF JOB: INDUSTRIAL ORIGINAL ALTERATI INSTALLATION ADDITIIONON REPAIR APPLICATION FOR HEATING PERMIT (C ntinued it m Reverse Side) 11. LOCATION OF JOB 40 C?a (a cu-), NO STREET 12. TYPE OF INSTALLATION: OIL BURNER rELECTRIC FLOOR VENTILATION SPRINKLER LJ GAS BURNER J STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE13. OF TANK OF TANK OF FILL OF VENT ta. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED - YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION; BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK/ ts. TO BE DONE: 16. HEa LOSS SCHEDULE. (TO BE I LUDED FOR ALL JOBS): Roots slzE wlNDows AREA - SQUARE FEET B.T.U. B.T.U. r oANDDOORSVOLUMEr DISTRIBUTION INSTALLED TOTAL TOTAL ROOM NO. 6 ORO" OLA9! NET WALL CEILING FLOOR CU.FT. AT A'F CORRECTED t j 4 L RAD. REGISTER L W N AND [ TEMP. TO F f TYPE AND SIZE OR LISTER SIZE < WALL Lfo INFILT.) OR SQ. FT.f EADER DIFF. F F m FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND is. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. /QG (9 -y DATE S16NATUR[OF APPLICANT COMMERCIIL LOAD ESTIMATE FOR PLEASANT HILLS CONDOMINIUM BY KURTZMAN VIOLETTE HTG A AIR COND. 06/06/84 CITY CURRENTLY STORE CITY : HARTFORD STATE : CONNECTICUT PRESS <ENTER> TO CONTINUE <1> TO CHANGE ABOVE ? A DESIGN DATA FOR HARTFORD k; ,LATITUDE a 42 ELEVATION (FEET) a 15 WINTER DESIGN TEMP a 3 SUMMER DESIGN DB a 91 SUMMER DESIGN WB a 74 DAILY RANGE a 22 MESS <ENTER> TO CONTINUE 1 a C 4 Q L I N 6 L 0 A D F A C T O R S N yE E SE S SW W NW H A R JUN WIND.SOLAI 45.16 79.26 133.60 91 .37 35 .45 10.32 15.57 13.28 134.01 Bt+R- 9 WALL TRANS -P5.25 0.41 10.20 4. 5 -4.90 -2. 72 -2. 35 -4.44 -1 . 31 WIND TRANS w 0.60 O.D. DB TEMP 75.6 O.D. WB TEMP - 69.0 JUL WIND.SOLAA 13.21 74.37 133. 12 100. 24 43.30 11 .33 15.52 12.46 129.55 XR- 9 WALL TRANS -2.25 3.12 13.33 8.5 -1 .82 0.56 0.67 -1 .48 1 . 59 WIND TRANS 3.60 O.D. DB TEMP - 78.6 O.D. WB TEMP - 71 .0 SEP WIND.SOLAR 8.50 .22.47 99.80 143.35 107 . 14 18.47 14 .97 6.60 131 .31 BR-10 WALL TRANS -7. 10 0.20 12. 10 11 . 1 -6.29 -4.57 -5.01 -6. 74 -2.89 WIND TRANS 0.40 O.D. DB TEMP - 75A O.D. WB TEMP 68.0 OCT WIND.SOLAR 7. 17 6. 61 . 26. 25 57 . 64 125. 16 141 . 87 55 .38 6. 72 93.68 8Y-14 WALL TRANS -11 .00 -9. 75 -4. 51 7 .43 18.48 -4 .94 -8.46 -10. 58 0. 17 WIND TRANS - -1 .00 O.D. DB TEMP - 74 .0 O.D. WB TEMP - 66.0 SEP WIND.SOLAR . 9.59 10. 15 28.42 42 .97 94 . 13 148. 19 102 .46 24 .92 115. 37 lib-15 WALL TRANS 1 . 15 2. 75 6. 74 15.07 26. 72 15.57 8. 13 1 .86 17 .95 WIND TRANS - .10.40 O.D. DB TEMP - 85.4 O.D. WB TEMP - 71 .0 lo. . WIND.SOLAR 15.91 19.97 26.44 28.89 32 .04 105.52 138 .22 .. .82 ,19,. 25 o dg a . Jt-16 WALL TRANS 8.50 10.80 12.40 16 . 1 21 .45 23 .75 19 .41 10.04 31 .90WINDTRANS15.00 O.D. DB TEMP - 90.0 O.D. WB TEMP 74.0 JUN WIND.SOLAR 18.31 21 .32 26.58 26.3E 26. 28 96. 33 138.93 88. 16 99. 33 ' tl12-16 WALL TRANS 5. 50 7.92 9.36 12 . 3 15.98 19. 23 16. 31 7 . 12 29. 33 WIND TRANS 12.00 O.D. DB TEMP 87 .0 O.D. WB TEMP 72 .0 22 FLATS FLATS 06-06-1984 RARTFORD CONNECTICUT LAT - 42 ALT 15 CONST- 70W/40R/ 70B III- 75 70 VALL COLORt MEDIUM ROOF CO OR: MEDIUM1.* SBR'/ 60215831 .6 D.B.TEMP TOTAL TONS RSt TONS CFM JUN AT 9 A.N. 75.6 1 .56 1 . 27 692 2. JUL AT 9 A,M. 78.6 1 . 71 1 .36 742 S. SIP AT 10 A.M. 75.4 1 .76 1 .49 811 4. OCT AT 2 P.M. 74.0 1 .90 1 .67 908 S. SEP AT 3 P.M. 85.4 2.40 2.02 1 , 102 i JUL AT 4, P.M. 90.0 2.56 ZAP 1 , 142 <- TW S S J. JUN AT 4IP.M. 87.0 2.42 ' 2.01 1 ,096 44#;95 INPUTS 30,66 CFM -558 ORIENTATION OF BUILDING N S W RF TRANS*ISSION FACTORS 0.08 0.08 0 08 0.00 0.08 aL F- .55 IS LI•FLO T SHADE FACT-0. 3 NO. FLOORS 216BM6TK + 24 WIM 34 . HEIGHT - 16. XVA.- 7 OUTPUTS NUMRER OF PEOPLE 4 SENSIBLE PEO LE LOAD - 980 TOTAL LIGHTS w ' 29160 LIGHTING LOA 9,215 OTHER ELECTRICAL 432 OTHER ELECTR CAL 1 ,474 AREA OF N. GLASS w 65 NORTH GLASS OLAR 648 AREA OF S. GLASS . 65 SOUTH GLASS OLAR 1 ,305 AREA OF E. GLASS . 0 EAST GLASS S LAR 0 AREA OF W. CLASS 60 WEST GLASS S LAR 51198 r`' AL GLASS A111A I" TOTAL GLASS OLAR 7, 152 TA;L GLASS AXIA 14* I", TOTAL GLASS RAMS. -1 , 567 AREA OF N., WAbL 319 N WALL LOAD 217 AXEA OF S. WALL .a 319 S. WALL LOAD 548 ARIA OF 8. WALL .+ 5.76 E. WALL LOAD 571 AREA OF W. WALt :.. 516 W. WALL LOAD 0 ZDTAL WALL AREA w 10730 TOTAL WALL T ANS. 1 , 336 AAU QF itoor '64 ROOF LOAD 2,205 UVRTT FACT"s `' 5E SAFETY B.T.U.S 1 , 197 PPLY FAN It.F. , ``--0.33 FAN HEAT GAI - DT -1 ,003 VENTILATION CFM • :`86 O.A. SENSIBL LOAD -1 ,46 UMBER OF PEOPLE 4 PEOPLE LATEN LOAD - 2 UNTILATION CFM * 86 O.A. LATENT LOAD 2,379 TAL CF*-STD. AIR-• 1,142 TOTAL LATENT LOAD 3, 199 r ROOM SENSIBLE 25, 127 ROOM LATENT 820 FLATS a-**> GRAND TOTAL LOAD •30,754 BTU'S OR 56 TON <-- (ef w hh,7*\ LOAD RUN FOR f 6. JUL AT 4P. . AREA (SQ FT) 1 ,728 SQ FT/TON 674 / s TOTAL CFM-STD AIR'. 1 . 142 CFM/SQ FT 0.66 HEATING LOAD VENTILATION LOAD - 6, 368 ROOF HEATING LOAD 4 , 631' GLASS HEAT LOAD - 7,001 WALL HEATING LOAD 6, 508 IHFTLTRATION LOAD- 6, 368 WARM UP LOAD 748 Il'JN WI,ND.SOLAR 18.31 21 .32 26. 58 26.38 26. 28 96 . 33 138.93 88. 16 99.3 HR-716 WALL TRANS 5. 50 7 .92 9. 36 12 . 36 15 .98 19. 23 16.31 7 . 12 29.3 WIND TRANS 12.00 O.D. DB TEMP 87 .0 O.D. WB TEMP = 72 .0 22 FLATS FLATS 06-06-1984 HARTFORD CONNECTICUT LAT - 42 ALT 15 CONST- 70W/4OR/ 70B ID- 75 70 WALL COLOR : MEDIUM ROOF COLOR: MEDIUM SER# 60215831 .6 D.B.TEMP TOTAL TONS RSH TONS CFM 1 . JUN AT 9 A.M. 75.6 1 . 56 1 . 27 692 2. JUL AT 9 A.M. 78. 6 1 .71 1 . 36 742 3. SEP AT 10 A.M. 75.4 1 .76 1 .49 811 4. OCT AT 2 P.M. 74.0 1 .90 1 .67 908 5 . SEP AT 3 P.M. 85.4 2.40 2,02 1 , 102 6. JUL AT 4 P.M. 90.0 2.56 1 , 142 .ZTgn Sy-S 7 . JUN AT 4 P.M. 87.0 2 .42 2.01 1 ,096 ZONE_HEATIN_G--> 24 , 295 W/INFIL- 30, 66 CFM -558 INPUTS ORIENTATION OF. BUILDING N S W RF TRANSMISSION FACTORS 0.08 0. 08 0. 08 0.00 0.08 - GL F- .55 IS LI-FLO Y SHADE FACT-0. 3 NO . FLOORS 2 LENGTH - 24 WIDTH - 36 HEIGHT a 16 2VA.- 7 OUTPUTS NUMBER OF PEOPLE = 4 SENSIBLE PEOPLE LOAD - 980 TOTAL LIGHTS m 2, 160 LIGHTING LOAD 9, 215 OTHER ELECTRICAL = 432 OTHER ELECTRICAL 1 ,474 AREA OF N. GLASS = 65 NORTH GLASS SOLAR w 648 AREA OF S. GLASS = 65 SOUTH GLASS SOLAR 1 ,305 AREA OF E. GLASS = 0 EAST GLASS SOLAR 0 AREA OF W. GLASS = 60 WEST GLASS SOLAR 5, 198 TOTAL GLASS AREA •r 190 TOTAL GLASS SOLAR 7, 152 TOTAL GLASS AREA 190 TOTAL GLASS TRANS. 1 ,567 AREA OF X. WALL = 319 N. WALL LOAD 217 1,41SA OF S. WALL = 319 S . WALL LOAD 548 AREA OF E. WALL . 576 E. WALL LOAD 571 WEA OF W. WALL = 516 W. WALL LOAD 0 TOTAL WALL AREA = 1 ,730 TOTAL WALL TRANS. 1 ,336 AREA OF ROOF 64 ROOF LOAD 2, 205 SAFETY FACTOR, SE SAFETY B.T.U.S 1 , 197 SUPPLY FAN H.P. 0.33 FAN HEAT GAIN - DT 1 ,003SUPPLY CFM = 86 O.A. SENSIBLE LOAD w 1 ,426 NUMBER OF PEOPLE - 4 PEOPLE LATENT LOAD - 820 VENTILATION CFM : 86 O.A. LATENT OAD 2 , 379 TOTAL CFM-STD AIR: 1 , 142 TOTAL LATENT OAD n 3, 199 ROOM SENSIBLE 25, 127 ROOM LATENT 820 FLATS GRAND TOTAL LOAD -30, 754 BTU'S OR 56TON <-- of 1,6, i1 LOAD' RUN FOR # 6. JUL AT 4 P.ySAREA (SQ FT) 1 ,728 SQ FT/TON m 674 / DOTAL CFM-STD AIR- 1 , 142 CFM/SQ FT 0.66 HEATING LOAD VENTILATION LOAD . 6,368 ROOF HEATING LOAD m 4,•631 1 iLASS HEAT LOAD = 7*001 WALL HEATING OAD 6 ,508 VFILTRATION LOAD= 6, 368 WARM UP LOAD 748 r$LAB HEATING LOAD= 5,407 HZAT LOAD WIT 30,663 COIL SELECTION PTRUMETERS wDB TEMP ENT/LVG 76. 1 / 54. 2 TOT SENSIBLE OAD m 27 . 555 AWL TEMP •BNTAY6 42.8 / 33.6 TOTAL COIL L AD 30,754 ipBCIFIED 100X RH• 552 RESULTING ROM RH 47% TERMINAL AIR TEMP. 55.00 / 120 DEGREES ROTATED 0 SUPPLY FAN STATIC• 1 .00 NON-CEILING RETURN BLDG. 'U' FACTOR-0. 10 CARRIER DEFA LTS S u 1, y S 1