Loading...
HomeMy WebLinkAboutBuilding 20 Arthur Drive (5)PERMIT # Application For 6462 6072 y DEPARTMENT DECISION Heating Permit C 3 APPLICATION IS HEREBY:DEPARTMENT OF LICENSES AND INSPECTIONS APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR o 12/21/84 Thomas P. D' Auria 00 Iv DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O C7 1. LOCATION OF JOB y ve Cd NO. STREET C1 L) L o r 20 L4 /7 r!1f 24J y LOT NO. FLOOR APT. NO. 0 O N n q 2. OWNER 1 6 FC +, o a. ADDRESS be 3 ai d S LtTjt 1 nI V CT 4.PHONE m V] S. APPLICANT A 7a B. ADDRESS yS9 John F o 7.PHONE yv, S. LICENSE NO. (/ Z a w0 9. EXPIRATION DATE OF LICENSE lo L//2 !C 10. ESTIMATED COST S o 1 t. IS THIS A CONTRACT COSTT TES O NO bo y 12. FEE ENCLOSED S e rm It 14066 mG v CU t a. TYPE 0 BUILDING: ILd RESIDENTIAL COMMERCIAL O E- 14. E OF JOB: INDUSTRIAL ai 3 AL TALLATION ADDITIONON REPAIR APPLICATION FOR HEATING PERMIT (C utinued it m Reverse Side) 11. LOCATION OF JOB 7-0 7 (w n NO. STREET FLOOR AFT. NO. 12. TYPE OF INSTALLATION: OIL BURNER 93 ELECTRIC minLATION SPRINKLER fJ GAS BURNER 1( STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SO. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. DESCRIPTION OF WORK _3 A fry15. TO BE DONE: IS. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): Roots a1zE AWINDOWSNDDOORS AREA - SQUARE FEET VOLUME B.T.U. O.T.U. I.)4 DISTRIBUTION INSTALLED TOTAL TOTAL R LL ROOM L W M ANO.ND W GROSS OLAaS NET WALL CEILING FLOOR CU.FT. AT A'F CORRECTED j RAD REGISTER WALL TO INFIFT.1 TEMP. TO k F TYPE AND SIZE OR LEADER SIZE F RIFF. F F m N SO' FT FREE AREA TOTALS 77 A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY- NAME ADDRESS SUBCONTRACTORS AND 1s. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. PLICATION TO BE COMPLETELY FILLED IN. N6 f f (q rLf v DATE SIGNATURE OF AprucANT V h g. r" RAW 8TIKAT$ KV lT if 'Tl TT% ,%lrf L AIR COND. 06/06/94 CITY CURRENTLY ST RED CITY NARTFORD STATR t G NJ.WTI40T PRESS <ZMTU> TO CONTIMME <1? TO CHANGE ABOVE ? DESIGN DATA FOR HARTFORD LATITUDE : 42 ELEVATION (FEET) : 15 WINTER DESIGN TEMP : 3 SUMMER DESIGN DB : 91 SUMMER DESIGN WB : 74 ... DAILY RANGE : 22 . PRESS <ENTER> TO CONTINUE ? C O O L I N G L 0 A F A C T O R S N NE E Sz S SW W NW H & R JUN WIND.SOLAR 15.18 79.26 133.60 91 .37 35 .45 10. 32 15.57 13 . 28 134.0 RR- 9 WALL TRANS -5.25 0.41 10.20 50 -4.90 -2 . 72 -2. 35 -4.44 -1 . 3 WIND TRANS 0.60 O.D. DB TEMP 75.6 O.D. WB TEMP - 69 .0 JUL WIND.SOLAR 13.21 74.37 133. 12 10). 24 43.30 11 .33 15.52 12.46 129.5 1IY- 9 WALL TRANS -2.25 3. 12 13.33 B. 58 -1 .82 0.56 0.67 -1 .48 1 . 5 WIND TRANS • 3.60 O.D. DB TEMP - 78.6 O.D. WB TEMP - 71 .0 SEP WIND.SOLAR 8.50 .22.47 99.80 143. 35 107. 14 18.47 14 .97 6.60 131 . 3 111-10 WALL TRANS -7. 10 0.20 12. 10 11 . 12 -6.29 -4.57 -5.01 -6. 74 -2.8 WIND TRANS 0.40 O.D. DB TEMP - 75.44 O.D. WB TEMP - 68.0 OCT WIND.SOLAR . 7. 17 6.61 . 26. 25 57 .64 125. 16 141 . 87 55 . 38 6. 72 93.6 14 WALL TRANS -11 .00 -9. 75 -4. 51 7 .43 18. 48 -4 . 94 -8.46 -10 . 58 0. 1 WIND TRANS . -1 .00 O.D. DB EMP 74.0 O.D. WB TEMP - 66.0 SEP WIND.SOLAR .9.59 10. 15 28.42 42 .97 94 . 13 148 . 19 102 .46 24 . 92 115.3 ill-15 WALL TRANS 1 . 15 2.75 6. 74 15.07 26. 72 15.57 8. 13 1 .86 17 .9 WIND TRANS . 10.40 O.D. DB TEMP - 85.4 O.D. WB TEMP - 71 .0 WIND.SOLAR 15.91 19.97 26.44 8.89 32 .04 105.52 138.22 . .82 4 lei 16 WALL TRANS 8.50 10.80 12.40 16 . 12 21 .45 23.75 19.41 10.04 31 .90 WIND TRANS . 15.00 O.D. DB TE14P 90.0 O.D. WB TEMP 74.0 JUN WIND.SOLAR 18.31 21 .32 26.58 26. 38 26 . 28 96. 33 138.93 88. 16 99.33 IR-16 WALL TRANS 5.50 7.92 9.36 12 . 36 15.98 19. 23 16. 31 7 . 12 29.33 WIND TRANS 12.00 O.D. DB TE P 87 .0 O.D. WB TEMP - 72 .0 22 FLATS FLATS 06-06-1984 EARTFORD CONNECTICUT LAT 42 ALT 15 CONST- 70W/40R/ 701S ID- 75 70 VA.LL COLORS MEDIUM ROOF CO OR: MEDIUM SER# 60215831 .6 D.B.TEMP TOTAL TONS RSH TONS CFM 1. JUN AT 9 A.M. 73.6 1 . 56 1 . 27 692 1!. JUL AT 9 A.M., 78.6 1 .71 1 . 36 742 SEP AT 10 A.M. 75.4 1 .76 1 .49 811 4, OCT AT 2 P.M. 74.0 1 .90 1 .67 908 5. SEP AT 3 P.M. , 85.4 2.40 2. 02 1 , 102 6. JUL AT 4, P.M. 90.0 2.56 V1.2-w 1 , 142 -- Tgti SAS t. JUN AT •Y.M. 87.0 2.42 ' 2.01 1 ,096 24,205 W/INFIL- 30,663 CFM -558 INPUTS OsRIENTATION OF BUILDING N S E W RF TRANSMISSION FACTORS 0.08 0.08 0.08 0.00 0.08 GL F- .55 IS LI-FLO I SHADE FACT 0.63 NO. FLOORS 2 GTH - 24 VIDTB * 36 HEIGHT - lf . VA.- 7 OUTPUTS NUMBER OF PEOPLE • 4 SENSIBLE IROPLE LOAD - 980 TOTAL LIGHTS 29160 LIGHTING 40AD 9, 215 OTHER ELECTRICAL • 432 OTHER ELE TRICAL 1 ,474 AREA OF N. GLASS • 65 NORTH GLA S SOLAR 648 AREA OF S. GLASS 65 SOUTH GLA S SOLAR 1 ,305 AREA OF E. GLASS 0 EAST GLAS SOLAR 0 AREA OF W. GLASS - 60 WEST GLAS SOLAR 5, 198 TOTAL GLASS AREA - 1.90 TOTAL GLASS SOLAR 7, 152 TOTAL GLASS AREA 190 TOTAL GLASS TRANS. -1 , 567 AREA OF N. WALL . 319 N. WALL LOAD 217 AREA OF S. WALL 319 S. WALL L AD 548 AREA OF E. WALL - 576 E. WALL L AD 571 AREA OF W. WALL - 516 W. WALL L AD 0 TOTAL WALL AREA - 1 ,730 TOTAL WAL TRANS. 1 , 336 AREA OF ROOF '864 ROOF LOAD 2, 205 SAFETY FACTOR 52 SAFETY B. .U.S 1 , 197 SUPPLY FAN H.P. w 0.33 FAN HEAT AIN - DT -1 ,003 VRNTILATION CFM - 86 O.A. SENS BLE LOAD -1 ,426 NUMBER OF PEOPLE 4 PEOPLE LA ENT LOAD - 820 UNTILATION GFK - 86 O.A. LAT NT LOAD 2 ,379 TOTAL CF*--ETD, AIR• 1, 142 TOTAL LAT NT LOAD 3, 199 WOM SENSIBLE 25, 127 ROOM LATE T 820 FLATS GRAND TOTAL LOAD -30.754 BTU'S 0 56 TO <-- ufrso d lw*\ r LOAD RUN FOR # 6. JUL A 4 P. . AREA (SQ FT) 1.7Z8 SQ FT/TON 674 / Sly 4,10TAL CFM-STD AIRm 1 , 142 CFM/SQ FT 0.66 HEATING LOAD VENTILATION LOAD - 6.368 ROOF HEATING LOAD 4 ,631' jGLASS HEAT LOAD - 79001 WALL HEA ING LOAD 6,508 INFTLTRATION LOAD- 6, 368 WARM UP OAD 748 N ' WIJ(D.SOLAR 18.31 21 .32 26.58 26 .38 26. 28 96 .33 138.93 88. 16 99.3 tR-16 WALL TRANS 5. 50 7.92 9. 36 12 . 36 15.98 19. 23 16. 31 7 . 12 29.3 WIND TRANS 12.00 O.D. DB TE P 87 .0 O.D. WB TEMP - 72 .0 22 FLATS FLATS 06-06-1984 HARTFORD CONRECTICUT LAT 42 ALT = 15 CONST- 70W/40R/ 70B ID; 75/5-5 70 WALL COLOR: MEDIUM SER# 60215831 .E RO)F O OR• MEDIUM D.B.TEMP TOTAL TONS RSH TONS CFM 1 . JUN AT 9 A.M. 75.6 1 . 56 1 . 27 692 2. JUL AT 9 A.M. 78 .6 1 . 71 1 .36 742 3. SEP AT 10 A.M. 75.4 1 . 76 1 .49 811 4. OCT AT , 2 P.M. 74.0 1 .90 1 .67 908 5. SEP AT 3 P.M. 85.4 2.40 2.02 1 , 102 6. JUL AT 4 P.M. 90.0 2.56 1 , 142 <- S SAr. 7. JUN AT 4 P.M'. 87.0 2.42 2.01 1 ,096 ZONE HEATING--> 24 ,295 W/INFIL- CO, 63 CFM -558 10RIENTATION OF BUILDING, INPUTS S E W RF RANSMISSIOH FACTORS 0.08 0.08 0. 08 0.00 0.08 - A" L F- .55 TS LIwFLO Y SHADE FACT= .63 NO. FLOORS 21. NGTH « 24 WIDTH • 36 HEIGHT - 16 OVA.- 7 OUTPUTS UttBEt OF PEOPFLa j•. 4 SENSIBLE PEOPLE LOAD - 980 f OTAL LIGHTS i Z,16® LIGHTING AD 9,215 Milli ELECT11CAL 432 OTHER ELECTRICAL a 19474 REA OF N. GLASS • 65 WORTH GLASS SOLAR 648 AREA OF S. CLASS . 65 SOUTH GLASS SOLAR 1 ,305 AREA OF E. GLASS . 0 EAST GLASS SOLAR 0 AREA OF W. GLASS • 60 WEST GLASS SOLAR 5, 198 ZVTOTAL GLASS AREA .r 190 TOTAL GLASS SOLAR 7, 152 TOTAL GLASS AREA 190 TOTAL GLASS TRANS. -1 , 567 ARBA OF N. WALL 319 N. WALL LOAD 217 r 4'AREA OF S. WALL - 319 S . WALL LOAD 548 4REA OF E. WALL - 576 E. WALL LOADf 571 4AREA OF W. WALL . 516 W. WALL LOAD 0 TOTAL WALL ARIA - 1 ,730 TOTAL WALI TRANS. 1 ,336 J1REA OF ROOF 864 ROOF LOAD 2,205 SAFETY FACTOR 52 SAFETY B. U.S 1 , 197 SUPPLY FAN H.P. .0.33 FAN HEAT AIN - DT -1 ,003 VENTILATION CFM 86 O.A. SENS BLE LOAD 1 ,48266 NUMBER OF PEOPLE - 4 PEOPLE LA ENT LOAD = VENTILATION CFM 86 O.A. LAT NT LOAD 2 ,379 TOTAL CFM-STD AIR- 1 , 142 TOTAL LATENT LOAD 3, 199 ROOM SENSIBLE 25, 127 ROOM LATE T 820 FLATS GRAND TOTAL LOAD 30, 754 BTU'S OF albi/ LOAD' RUN FOR # 6. JUL Al4 P. SAREA (SQ FT) 1 ,728 SQ FT/TON 674 y TOTAL CFM-STD AIR- 1 , 142 CFM/SQ FT 0.66 HEATING LOAD VENTILATION LOAD - 6, 368 ROOF HEAT NG LOAD 4 ,•631 GLASS HEAT LOAD - 7,001 WALL HEAT NG LOAD 6, 508 INFILTRATION LOAD- 6, 368 WARM UP L AD 748 SLAB HEATING LOAD- 5,407 HEAT LOAD WITH V 30,663 COIL SELECTION PARAMETERS DB TEMP ENT/LVG = 76. 1 / 54 . 2 TOT SENSIBLE LOAD 27 . 555 TOTAL COIL LOAD 30,754 I 11, 1 I R SIAX RISULTING OON RH 47x MINAL AIR TEMP• 55.00 / 120 DEGREES ROT TED 0 SUPPLY FAN STATIC- 1.00 NON-CEILIN RETURN FACTOR•0.10 CARRIER DE AULTS r----------------------------------------- ------------ j J A