HomeMy WebLinkAboutBuilding 17 Arthur Drive (5)PERMIT
Application For 6 617 6227
y DEPARTMENT DECISION Heating Permit
d
3 APPLICATION Is HEREBY:
DEPARTMENT OF LICENSES AND INSPECTIONS
d Q) 3S APPROVED El DISAPPROVED
c TOWN OF SOUTH WINDSOR
do 8/23/85 Thomas P. D'Auria
00 DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW
O41
C 1. LOCATION OF JOB
I.7Or eve
G NO. STREET
CL HI/f-S fTj te
0 LOT NO. FLOOR APT. NO.
y ON
d
2. OWNER
00
O S. ADDRESS -
be
y ; SO(Ant w/4 11 (IPe Cf-06aT/ 4.PHONE
to
rj2 S. APPLICANT V I /C N'TZ.hl4s/
di a0
1,
s. ADDRESS 7 r9 •T/ F TG 1 /f
A
4,14 JP/C-f 0 6 0"01 7.PHONE ra—yio
s. LICENSE NO. 30I LO 3
0 ,+', B. EXPIRATION DATE OF LICENSE o/dl"
c G 10. ESTIMATED COST ! ` Z6 r{ N4 /T
v
o
bD
t 1. IS THIS A CONTRACT COST?K YES 0 NO
re-12. FEE ENCLOSED ! Fml i t 14535
x
X
vvi m Is. TYPE
j]
OOFF BUILDING:
rn 3 BESIDEMTIAL COMMERCIAL
O C
CIS 3 14. TYPE OF B: INDUSTRIAL
ORIGINAL ALTERATIONINSTALLATIONADDITION
REPAIR
APPLICATQION FOR HEATING PERMIT (Continu d/ it m Reverse Side)
J.
11. LOCATION OF JOB v 14 ti 1 fo- //r yt fT ZAat
0. STREETS FLOOR AFT'NO.
112TYPE OF INSTALLATION: OIL BURNER MILECTRIC VENTILATION SPRINKLER
0--GASGAS BURNER L'S STACK INCINERATOR MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE
BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE
FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO
TYPE OF WALL INSULATION ROOF OR CEILING INSULATION
AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT
MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ.
FT. OR B.T.U.
DESCRIPTION OF WORK•-,
is. TO BE DONE: LA1 •(//1 « AAd /' I T //A O(7L1 lti o/,T
r'cf.o- t; -4a
1s. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
ROOM SIZE AREA - SQUARE FEET O F OANDDoonaMINOOMSAE.T.U. e.T.U.
VOLUME TOTAL TOTAL <
I- DISTRIBUTION INSTALLED
S,I
ROOM NO. < GROSS OLAS! NET MALL CEILING FLOOR CU.FT. AT A•F CORRECTED J LL
jU. REGISTER
L M N AN D `W TEMP. TO Fhb f TYPE AND SIZE RAD. OR LEADER
SIZE < MALL 10 INFILT.) DIFF. F F IS u0i 30. FT. FREE AREA
TOTALS
A. HEAT LOSS FROM BUILDING B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND B.T.U./HR.
C. PIPING, OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
1B. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN.
k9 lyyr
DATE SIGNATURE OF APPbffjANT vF
ARTFORD CON.NECTICUT LAT = 42 ALT = 15
ST- 70W/46R/ 70B ID= 75 70
L COLOR: MEDIUM ROOF COLOR: MEDIUM
SERI 60215831 . 6
D.B .TEMP TOTAL TONS R H TONS CFM
JUN AT 9 A.M. 75. 6 1 . 56 1 . 27 692
JUL AT 9 A.M. 78 . 6 1 . 71 1 . 36 742
SEP AT 10 A.M. 75.4 1 . 76 1 . 49 811
OCT AT 2 P.M. 74 .0 1 .90 1 .67 908
SEP AT 3 P.M. 85.4 2.40 2 .02 1 , 102
JUL AT 4 P.M. 90.0 2 .56 vlJw_ 1 , 142 <- ZT s S r•
JUN AT 4 P.M. 87 . 0 2 .42 2 .01 1 ,096
HEATI G--> 24, 295 W/INFIL- 30, 6 3 CFM -558
INPUTS
ZENTATION OF BUILDING N S E W RF
NSMISSION FACTORS 0. 08 0. 08 0. 08 0.00 0. 08
F- .55 IS LI-FLO Y SHADE FACT=0 63 NO. FLOORS 2
GTH - 24 WIDTH - 36 HEIGHT - 16 VA.= 7
OUTPUTS
BER OF PEOPLE' S 4 SENSIBLE PE PLE LOAD 980
AL LIGHTS 2 , 160 LIGHTING LOAD 9 , 215
ER ELECTRICAL - 432 OTHER ELECTRICAL 1 ,474
A OF N. GLASS - 65 NORTH GLASS SOLAR 648
EA OF S. GLASS - 65 SOUTH GLASS SOLAR 1 ,305
EA OF E. GLASS 0 EAST GLASS ISOLAR 0
REA OF W. GLASS - 60 WEST GLASS ISOLAR 5 , 198
AL GLASS AREA -1.90 TOTAL GLASS SOLAR 7 , 152
TAL GLASS AREA - 190 TOTAL GLASS TRANS . =1 , 567
SEA OF N. WALL - 319 N. WALL LOA 217
XKA OF S . WALL - 319 S . WALL LOA 548
REA OF E. WALL - 576 E. WALL LOA 571
it EA OF W. WALL - 516 W. WALL LOA 0
TAL WALL AREA - 1 , 730 TOTAL WALL RANS . 1 , 336
A OF ROOF 864 ROOF LOAD 2 , 205
AFETY FACTOR 5% SAFETY B .T. .S 1 , 197
SUPPLY FAN H.P. -0. 33 FAN HEAT GA N - DT -1 ,003
ENTILATION CFM - 86 O.A. SENSIB E LOAD 1 ,48266
UMBER OF PEOPLE - 4 PEOPLE LATE T LOAD =
ENTILATION CFM - 86 O. A. LATEN LOAD 2 , 379
QTAL CFM-STD AIR- 1 , 142 TOTAL LATEN LOAD 3 , 199
BOOM SENSIBLE 25 , 127 ROOM LATENT 820
FLATS
7> GRAND TOTAL LOAD -30, 754 BTU' S OR 56 TON <-- us
LOAD RUN FOR # 6. JUL AT 4 P . cis
AREA (SQ FT) 1 , 728 SQ FT/TON 674
OTAL CFM-STD AIR- 1 , 142 CFM/SQ FT 0 . 66
HEATING LOAD
ENTILATION LOAD - 6, 368 ROOF HEATING LOAD 4 , 631
GLASS HEAT LOAD - 7 ,001 WALL HEATIN7 LOAD 6, 508
INFILTRATION LOAD- 6, 368 WARM UP LOA 748
LAB HEATING LOAD- 5 ,407 HEAT LOAD W TH VENT = 30 , 663
COIL SELECTION PARAMMERS
TEMP ENT/LVG - 76 . 1 / 54 . 2 TOT SENSIBLE LOAD 27 , 555
B TEMP ENT/LVG - 62. 8 / 53 . 6 TOTAL COIL LOAD 30, 754
CIFIED ROOM RH- 55% RESULTING ROOM RH 47%
MINAL AIR TEMP- 55 .00 / 120 DEGREES ROTA ED 0
PPLY FAN STATIC- 1 .00 NON-CEILING RETURN
G. 'U' FACTOR-0. 10 CARRIER DEF ULTS
r---------------------------------------- -----------------