Loading...
HomeMy WebLinkAboutBuilding 14 Arthur Drive (5)PERMIT # Application For 6 618 6228 y DEPARTMENT DECISION Heating Permit 0 3 APPLICATION IS HEREBY:I. DEPARTMENT OF LICENSES AND INSPECTIONS APPROVED DISAPPROVED 41 TOWN OF SOUTH WINDSOft I. o ; 8/23/85 Thomas P. D'Auria d DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O A o 1. LOCATION OF JOB c o NO. STREET rA LOT NO. FLOOR APT. NO. O 41 lV d f 2. OWNER v /r R+ Cd Ce 00 G S. ADDRESS 6 Za OgC( 0 3 Gnl //ItJl GTGlsd7y 4.FHONE m Lr'f /1S /l 4 l"'Z yf 4iUJxS. APPLICANT 7 o aD 6. ADDRESS Yj"`rl ..?? j gllid aMi SOc r 4-,//I jse,r Cj- 7.PHONE B. LICENSE NO. 3Q1 L4P 3 CL 4S w S. EXPIRATION DATE OF LICENSE. ca 1, c 10. ESTIMATED COST s q( ZG — /r o.*,T AV m 1 I. IS THIS A CONTRACT COS"Imo'YES NO bo y C 12. FEE ENCLOSED S Permit 14482 U aki 1s. TYPE OF-BUILDING: d BtSIDtMTU1L COMMERCIALb0 O rz a)14. TYPE OF JOB: INDUSTRIAL ai 3 ITALLATION ADDITALTERAONONNS REPAIR APPLICATION FOR HEATING PERMIT (Continued it m R verse Side) 11. LOCATION OF JOB 13 (y 1 / A r A wr ol-i t -c 2 A d NO. STREET FLOORLOOR APT. NO. 12.TYPE OF INSTALLATION:: OIL BURNER 0 ELECTRIC VENTILATION SPRINKLER 0 AS BURNER L7 STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SO. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK r eyT O/4 e r- I'Y ITiriIs. TO BE DONE: t y q a"_ L_ 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM SIZE AND DODR! AREA — SQUARE FEET VOLUME B.T.U. [.T.U. g DISTRIBUTION INSTALLED TOTAL TOTAL ROOM NO.GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT]O•F CORRECTED J Nj 4 REGISTER L WF AND [ TEMP. TO F: TYPE AND SIZE RAD. OR LEADER SIZE < WALL F' to INFILT.) DIFF. F m N O• FT. FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND is. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. /1 , _ j /or. Q Ly DATE (SIGNATURE OF A CANT HARTFORD CONNECTICUT LAT = 42 ALT = 15 ST- 70W/40R/ 70B ID= 75 70 L COLOk: MEDIUM ROOF COLOR : MEDIUM SER# 60215 31 .6 D.B.TEMP TOTAL TONS RSH TONS CFM JUN AT 9 A.M. 75. 6 56 1 . 27 692 2. JUL AT 9 A.M. 78 . 6 71 1 . 36 742 SEP AT 10 A.M. 75.4 76 1 .49 811 OCT AT 2 P.M. 74 .0 90 1 . 67 908 SEP AT 3 P.M. 85. 4 40 2 . 02 1 , 102 JUL AT 4 P.M. 90 .0 56 Q-..W 1 , 142 Z Tctin S S 7 . JUN AT 4 P.M. 87 .0 1. 42 2 .01 1 , 096 E HEATING--> 24 , 295 W/INF L- 30 , 663 CFM -558 INPUTS IENTATION OF BUILDING N S E W RF RANSMISSION FACTORS 0. 08 0 . 08 0,08 0.00 0 . 08 L F- .55 IS LI-FLO Y SH DE FACT=0. 63 NO . FLOORS 2 NGTH - 24 WIDTH 36 HE GHT - 16 VA .= 7 OUTPUT 1UMBER OF PEOPLE = 4 S NSIBLE PEOPLE LOAD = 980 OTAL LIGHTS 2 , 160 L GHTING LOAD 9 , 215 THER ELECTRICAL - 432 0 HER ELECTRICAL 1 , 474 REA OF N. GLASS 65 NORTH GLASS SOLAR 648 AREA OF S . GLASS - 65 SOUTH GLASS SOLAR 1 ,305 REA OF E. GLASS - 0 E ST GLASS SOLAR 0 AREA OF W. GLASS = 60 W ST GLASS SOLAR 5 , 198 t1TAL GLASS AREA -190 T TAL GLASS SOLAR 7 , 152 TAL GLASS AREA = 190 T TAL GLASS TRANS . =1 , 567 REA OF N. WALL - 319 N WALL LOAD 217 REA OF S . WALL - 319 S WALL LOAD 548 it,EA OF E. WALL - 576 E WALL LOAD 571 EA OF W. WALL - 516 W WALL LOAD 0 AL WALL AREA 1 , 730 TOTAL WALL TRANS . 1 , 336 A OF ROOF 864 ROOF LOAD 2 , 205 ETY FACTOR 5% S FETY B.T.U.S 1 , 197 APPLY FAN H.P. -0. 33 F N HEAT GAIN - DT =1 ,003 TILATION CFM - 86 0 A. SENSIBLE LOAD =1 ,426 U14BER OF PEOPLE - 4 P OPLE LATENT LOAD = 820 NTILATION CFM w 85 0 A . L."-TENT LOAD 2 , 379 QTAL CFM-STD AIR- 1 , 142 TOTAL LATENT LOAD 3 , 199 M SENSIBLE 25 , 127 ROOM LATENT 820 FLATS 0 GRAND TOTAL LOAD -30, 754 TU' S OR 56 TON <-- LOAD RUN FOR # 6 JUL AT 4 1) . EA (SQ FT) 1 , 728 S FT/TON 674 S AL CFM-STD AIR- 1 , 142 C M/SQ FT 0.66 HEATING L AD TILATION LOAD - 6, 368 R OF HEATING LOAD 4 , 631 LASS HEAT LOAD - 7,001 W LL HEATING LOAD 6 , 508 FILTRATION LOAD= 6, 368 W RM UP LOAD 748 B HEATING LOAD- 5 ,407 H AT LOAD WITH VENT 30, 663 COIL SELECTION PA AM ER TEMP ENT/LVG - 76 . 1 / 54 . 2 T T SENSIBLE LOAD 27 , 555 TEMP ENT/LVG - 62 . 8 / 53. 6 T TAL COIL LOAD 30, 754 IFIED ROOM RH- 55% R SULTING ROOM RH 47% MINAL AIR TEMP- 55.00 / 120 DEGREES ROTATED 0 PLY FAN STATIC- 1 .00 NON-CEILING RETURN U' FACTOR-0. 10 CARRIER DEFAULTS