HomeMy WebLinkAboutBuilding 14 Arthur Drive (5)PERMIT #
Application For 6 618 6228
y DEPARTMENT DECISION Heating Permit
0
3 APPLICATION IS HEREBY:I. DEPARTMENT OF LICENSES AND INSPECTIONS
APPROVED DISAPPROVED
41 TOWN OF SOUTH WINDSOft
I.
o ; 8/23/85 Thomas P. D'Auria
d DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW
O
A
o 1. LOCATION OF JOB
c o NO. STREET
rA LOT NO. FLOOR APT. NO.
O
41
lV
d
f
2. OWNER v /r R+
Cd
Ce
00 G S. ADDRESS
6 Za OgC(
0 3
Gnl //ItJl GTGlsd7y 4.FHONE
m
Lr'f /1S /l 4 l"'Z yf 4iUJxS. APPLICANT 7
o aD 6. ADDRESS Yj"`rl ..?? j gllid
aMi
SOc r 4-,//I jse,r Cj- 7.PHONE
B. LICENSE NO. 3Q1 L4P 3
CL 4S
w S. EXPIRATION DATE OF LICENSE.
ca
1, c 10. ESTIMATED COST s q( ZG — /r o.*,T AV
m
1 I. IS THIS A CONTRACT COS"Imo'YES NO
bo
y C
12. FEE ENCLOSED S
Permit 14482
U
aki 1s. TYPE OF-BUILDING:
d BtSIDtMTU1L COMMERCIALb0
O rz
a)14. TYPE OF JOB: INDUSTRIAL
ai 3
ITALLATION ADDITALTERAONONNS
REPAIR
APPLICATION FOR HEATING PERMIT (Continued it m R verse Side)
11. LOCATION OF JOB 13 (y 1 / A r A wr ol-i t -c 2 A d
NO. STREET FLOORLOOR APT. NO.
12.TYPE OF INSTALLATION:: OIL BURNER 0 ELECTRIC VENTILATION SPRINKLER
0 AS BURNER L7 STACK INCINERATOR MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE
13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE
BOILER OR FURNACE MAKE AND NO. B.T.U. OR SO. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE
FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO
TYPE OF WALL INSULATION ROOF OR CEILING INSULATION
AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT
MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ.
FT. OR B.T.U.
DESCRIPTION OF WORK r eyT O/4 e r- I'Y ITiriIs. TO BE DONE: t y q a"_ L_
16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
ROOM SIZE AND DODR! AREA — SQUARE FEET VOLUME
B.T.U. [.T.U. g DISTRIBUTION INSTALLED
TOTAL TOTAL
ROOM NO.GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT]O•F CORRECTED J Nj 4 REGISTER
L WF AND [ TEMP. TO F: TYPE AND SIZE
RAD.
OR LEADER
SIZE < WALL
F'
to INFILT.) DIFF. F m N O• FT. FREE AREA
TOTALS
A. HEAT LOSS FROM BUILDING B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND B.T.U./HR.
C. PIPING. OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
is. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN. /1 , _
j /or. Q Ly
DATE (SIGNATURE OF A CANT
HARTFORD CONNECTICUT LAT = 42 ALT = 15
ST- 70W/40R/ 70B ID= 75 70
L COLOk: MEDIUM ROOF COLOR : MEDIUM
SER# 60215 31 .6
D.B.TEMP TOTAL TONS RSH TONS CFM
JUN AT 9 A.M. 75. 6 56 1 . 27 692
2. JUL AT 9 A.M. 78 . 6 71 1 . 36 742
SEP AT 10 A.M. 75.4 76 1 .49 811
OCT AT 2 P.M. 74 .0 90 1 . 67 908
SEP AT 3 P.M. 85. 4 40 2 . 02 1 , 102
JUL AT 4 P.M. 90 .0 56 Q-..W 1 , 142 Z Tctin S S
7 . JUN AT 4 P.M. 87 .0 1. 42 2 .01 1 , 096
E HEATING--> 24 , 295 W/INF L- 30 , 663 CFM -558
INPUTS
IENTATION OF BUILDING N S E W RF
RANSMISSION FACTORS 0. 08 0 . 08 0,08 0.00 0 . 08
L F- .55 IS LI-FLO Y SH DE FACT=0. 63 NO . FLOORS 2
NGTH - 24 WIDTH 36 HE GHT - 16 VA .= 7
OUTPUT
1UMBER OF PEOPLE = 4 S NSIBLE PEOPLE LOAD = 980
OTAL LIGHTS 2 , 160 L GHTING LOAD 9 , 215
THER ELECTRICAL - 432 0 HER ELECTRICAL 1 , 474
REA OF N. GLASS 65 NORTH GLASS SOLAR 648
AREA OF S . GLASS - 65 SOUTH GLASS SOLAR 1 ,305
REA OF E. GLASS - 0 E ST GLASS SOLAR 0
AREA OF W. GLASS = 60 W ST GLASS SOLAR 5 , 198
t1TAL GLASS AREA -190 T TAL GLASS SOLAR 7 , 152
TAL GLASS AREA = 190 T TAL GLASS TRANS . =1 , 567
REA OF N. WALL - 319 N WALL LOAD 217
REA OF S . WALL - 319 S WALL LOAD 548
it,EA OF E. WALL - 576 E WALL LOAD 571
EA OF W. WALL - 516 W WALL LOAD 0
AL WALL AREA 1 , 730 TOTAL WALL TRANS . 1 , 336
A OF ROOF 864 ROOF LOAD 2 , 205
ETY FACTOR 5% S FETY B.T.U.S 1 , 197
APPLY FAN H.P. -0. 33 F N HEAT GAIN - DT =1 ,003
TILATION CFM - 86 0 A. SENSIBLE LOAD =1 ,426
U14BER OF PEOPLE - 4 P OPLE LATENT LOAD = 820
NTILATION CFM w 85 0 A . L."-TENT LOAD 2 , 379
QTAL CFM-STD AIR- 1 , 142 TOTAL LATENT LOAD 3 , 199
M SENSIBLE 25 , 127 ROOM LATENT 820
FLATS
0 GRAND TOTAL LOAD -30, 754 TU' S OR 56 TON <--
LOAD RUN FOR # 6 JUL AT 4 1) .
EA (SQ FT) 1 , 728 S FT/TON 674 S
AL CFM-STD AIR- 1 , 142 C M/SQ FT 0.66
HEATING L AD
TILATION LOAD - 6, 368 R OF HEATING LOAD 4 , 631
LASS HEAT LOAD - 7,001 W LL HEATING LOAD 6 , 508
FILTRATION LOAD= 6, 368 W RM UP LOAD 748
B HEATING LOAD- 5 ,407 H AT LOAD WITH VENT 30, 663
COIL SELECTION PA AM ER
TEMP ENT/LVG - 76 . 1 / 54 . 2 T T SENSIBLE LOAD 27 , 555
TEMP ENT/LVG - 62 . 8 / 53. 6 T TAL COIL LOAD 30, 754
IFIED ROOM RH- 55% R SULTING ROOM RH 47%
MINAL AIR TEMP- 55.00 / 120 DEGREES ROTATED 0
PLY FAN STATIC- 1 .00 NON-CEILING RETURN
U' FACTOR-0. 10 CARRIER DEFAULTS