HomeMy WebLinkAboutBuilding 13 Arthur Drive (5)f——PERMIT #
Application For 662@ 6230
y DEPARTMENT DECISION Heating Permit
d
3 APPLICATION IS HEREBY:DEPARTMENT OF LICENSES AND INSPECTIONS
N " APPROVED DISAPPROVED
w TOWN OF SOUTH WINDSOR
o p 26/85 Thomas P. D'Auria
00 O DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW
O
E ^CS 1. LOCATION OF JOB
O a)
so
ca NO. STREET
O
Cd 8 !3—3 iTj I SrF a.lxLOTN0. FLOOR AR. N0.
O r ON
E 2. OWNER tv
lac r
a c S. ADDRESS bZ L ,l/Ay1'Zn G9+
b0 3
J a>4.PHONE
S. APPLICANT
u
1 'c //[urTsZA!4 I
B. ADDRESS 7 D /l 1 I1—jTC4 )j1Ud/
SUu wreltj,r GT OG i.PHONE f'2-Y-IIY7
w 'G
s. LICENSE NO. 3 0 Z y3
E w s. EXPIRATION DATE OF LICENSE
0v v'
c 10. ESTIMATED COST s y/
04
o Cu
E IS THIS A CONTRACT COST?0 YES Ofb0
07
Permit #14288III. FEE ENCLOSED S
a> dU
4X>is. TYPE OOFF BUILDING:
g RESIDENTIAL COMMERCIAL
O G
asa 3 14. TYPE OF JOB: INDUSTRIAL
as
ALLATION ADDITIONON
REPAIR
APPLICATION FOR HEATING PERMIT (C ntinued tr m Reverse Side)
11. LOCATION OF JOB J I-i /3 — 3 NA 0)Arrhw-
NO. STREET FLOOR APT.NO.
1 2. TYPE OF INSTALLATION:: ElSOILBURNERLid—ELECTRIC VENTILATION SPRINKLER
El/GAS BURNER M STACK INCINERATOR MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE
13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE
BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE
FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO
TYPE OF WALL INSULATION ROOF OR CEILING INSULATION
AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT
MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO.
FT. OR B.T.U.
DESCRIPTION OF WORKl4 7` A4^0_ ol4Cr y vr/( /^ey/lTfrrIs. TO BE DONE:
P-f rigecl S rT.11a
is. HEAT L SS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
ROOy SIZE WINDOWS AREA - SQUARE FEET IS.T.U. 0.T.U. O DISTRIBUTION INSTALLED
AND DOORS VOLUME TOTAL TOTAL
RODy NO. < GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT
T
A•F CORRECTED t:I4
TYPE AND SIZE RAD.
REGISTER
L W N AND W TEMP. TO F OR LEADERaINFIIT.I I)F O O. FT.SIZE < WALL
f'
10 DIFF. F F m N FREE AREA
P fn r
TOTALS
A. HEAT LOSS FROM BUILDING B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND B.T.U./HR.
C. PIPING, OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
1e. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN. i4 Zv lyxr
DATE I SIGNATURVOF APPLICANT
HARTF0RD CUNNECTiCUT LA`1' = 42 ALT = 15
CONST- 70W/40R/ 70B ID= 75 70
ALL COLOR: MEDIUM ROOF COLOR : MEDIUM
SER# 6021 831 . 6
D.B.TEMP TOTAL TONS RSH TONS CFM
1 . JUN AT 9 A.M. 75. 6 1 . 56 1 . 27 692
2. JUL AT 9 A.M. 78 . 6 1 . 71 1 . 36 742
3. SEP AT 10 A.M. 75.4 1 . 76 1 .49 811
J 9 OCT AT 2 P.M. 74 .0 1 .90 1 . 67 908
5. SEP AT 3 P.M. 85.4 2.40 2 .02 1 , 102
JUL AT 4 P.M. 90.0 2 .56 Q.,9A7 1 , 142 <- 2To^ S S
JUN AT 4 P.M. 87.0 2 . 42 2 .01 1 ,096
E HEATING--> 24 , 295 W/IN IL- 30, 663 CFM =558
INPUT
RIENTATION OF BUILDING N S E W RF
4F 5 ISSMI5IONALI 8 0.00 O
FLO Y SHADE FACT-0. 63NO. FLOORS2
TGTH - 24 WIDTH 36 HEIGHT - 16 VA.- 7
OUTPUTS
UMBER OF PEOPLE - 4 SENSIBLE PEOPLE LOAD = 980
TAL LIGHTS 2 , 160 LIGHTING LOAD 9, 215
HER ELECTRICAL - 432 OTHER ELECTRICAL 1 , 474
3tEA OF N. GLASS - 65 NORTH GLASS SOLAR 648
AREA OF S. GLASS - 65 SOUTH GLASS SOLAR 1 , 305
AEA OF E . GLASS - 0 EAST GLASS SOLAR 0
AREA OF W. GLASS - 60 WEST GLASS SOLAR 5 , 198
OTAL GLASS AREA -190 TOTAL GLASS SOLAR 7 , 152
TAL GLASS AREA - 190 TOTAL GLASS TRANS . 1 , 567
AEA OF N. WALL - 319 N. WALL LOAD 217
AEA OF S . WALL 319 S . WALL LOAD 548
3tEA OF E . WALL - 576 E. WALL LOAD 571
REA OF W. WALL - 516 W. WALL LOAD 0
TAL WALL AREA - 1 , 730 TOTAL WALL TRANS . 1 , 336
JA OF ROOF 864 ROOF LOAD 2 , 205
AFETY FACTOR 5% SAFETY B .T.U.S 1 , 197
UPPLY FAN H.P. -0. 33 FAN HEAT GAIN - DT -1 ,003
A,NTILATION CFM - 86 O.A. SENSIBLE LOAD =1 ,426
UMBER OF PEOPLE - 4 PEOPLE LATENT LOAD = 820
BNTILATION CFM - 86 O.A . LATENT LOAD 2 , 379
TAL CFM-STD AIR- 1 , 142 T TAL LATENT LOAD 3 , 199
OM SENSIBLE 25 , 127 R OM LATENT 820
FLATS
GRAND TOTAL LOAD =30, 754 TU' S OR 56 TON <--
LOAD RUN FOR # 6. JUL AT 4 1, SAREA (SQ FT) 1 , 728 S FT/TON 674
TAL CFM-STD AIR- 1 , 142 C M/SQ FT 0.66
HEATING L AD
VENTILATION LOAD - 6, 368 R OF HEATING LOAD 4 , 631
GLASS HEAT LOAD - 7 ,001 W LL HEATING LOAD 6 , 508
INFILTRATION LOAD- 6, 368 W RM UP LOAD 748
LAB HEATING LOAD- 5 , 407 H T LOAD WITH VENZ - 30, 663
COIL SELECTION PA AMETERS
E TEMP ENT/LVG - 76 . 1 / 54 . 2 T T SENSIBLE LOAD 27 , 555
B TEMP ENT/LVG - 62. 8 / 53. 6 T TAL COIL LOAD 30, 754
CIFIED ROOM RH- 55% RESULTING ROOM RH 47%
RMINAL AIR TEMP- 55.00 / 120 DE REES ROTATED 0
PPLY FAN STATIC• 1 .00 N N-CEILING RETURN
G. 'U' FACTOR-0. 10 C RRIER DEFAULTS
po-------------------------------- ---------------------------