HomeMy WebLinkAboutBuilding 12 Arthur Drive (5)PERMIT #
Application For 6502 6112
y DEPARTMENT DECISION
eSting Permit
O
3 APPLICATION IS HEREBY:
O
DEPARTMENT OF LICENSES AND INSPECTIONS"
N " APPROVED DISAPPROVED
TOWN OF SOUTH WINDSOR
0 a 3/18/85 Thomas P. D' Auria
00 d DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW
O
V1
0 ^O 1. LOCATION OF RRTPU R D R 1 YC10
NO. STREET
rn
r I q W f-f-
y LOT NO. FLOOR A T. NO.
O 0ON
2. OWNER n4P4
Cd
3 0 S. ADDRESS Z
3
ai a SUN171 llio.? d d [r- 4.FHONET4L 17iJ'7
rCdx S- APPLICANT IL6M d `Nr hAy n
vi c0
o m B. ADDRESS Y S"rf
SUS/ k11/J d J Li C/ 4GL 7y Y.PHONE F 7
B. LICENSE NO. 2,
Ll
C w B. EXPIRATION DATE OF LICENSE L
to. ESTIMATED COST B
0 eq3 ^
II. IS THIS A CONTRACT COSTT CI YES
bo
12. FEE ENCLOSED B Permit 14223
x
axi 13. TYP O/F-OUILDING:
bi CJ RESIDENTIAL COMMERCIAL
O K
14. TYPE OF B: INDUSTRIALcis
ALTERATI
IINSTALLATION ADDITIIONON
REPAIR
APPLICATION FOR HEATING PERMIT (Continued it m Reverse Side)
11. LOCATION OF JOB LU t 7 '7Afn 51,C)a #)- All awe
NO. STREET FLOOR APT. NO.
12. TYPE OF INSTALLATION: OIL BURNER fd ELECTRIC VENTILATION SPRINKLER
GAS BURNER l STACK INCINERATOR MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE
13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE
BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE
FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED - YES OR NO
TYPE OF WALL INSULATION ROOF OR CEILING INSULATION
AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT
MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO.
FT. OR B.T.U.
DESCRIPTION OF WORK r rr rn 17 d/G.- LL
15. TO BE DONE: d S n+ l 6 T NniO/ [ti/CT •/( ', /!f/J-7'!/f
CI/1 cT rl4-1 It /`y l?crr S XXI'Af" Ic r X"w 7— f
16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
INDOWSROOMSIZEANDDOORS AREA - SQUARE FEET
VOLUME
B.T.U. s.T.U. ¢ f°p<F DISTRIBUTION INSTALLED
TOTAL TOTAL LL
ROOM NO'GRO&1 OLAS! NET WALL ClILING FLOOR CU.FT. AT A•F CORRECTED J j LL REGISTER
L R N AND C TEMp, TO F F a TYPE AND SIZE
RAD' OR LEADER
SIZE < WiALL to IINFILT.1 O SO. FT.
f DIFF. F m N FREE AREA
TOTALS
A. HEAT LOSS FROM BUILDING B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND B.T.U./HR.
C. PIPING, OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
16. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN.
4 ti lyY r
DATE it NATUR[ 4PPLICA
MR-16 WALL TRANS 8 . 50 10. 80 12 . 40 16 . 1 21 . 45 23 . 75 19 . 41 10 . 04 31 .90
WIND TRANS - 15 .00 O . D . DB TEMP = 90. 0 O .D . WB TEMP = 74 .0
JUN WIND.SOLAR 18 . 31 21 . 32 26 . 58 26 . 313 26 . 28 96 . 33 138 . 93 88 . 16 99 . 33
SR-16 WALL TRANS 5 . 50 7 . 92 9 . 36 12 . 36 15 . 98 19 . 23 16 . 31 7 . 12 29 . 33
WIND TRANS 12 .00 O. D. DB TEMP = 87 . 0 O . D . WB TEMP = 72 .0
22 FLATS
FLATS
06-06-1984
HARTFORD CONNECTICUT LAT = 4 ALT = 15
CONST- 70W/4OR/ 70B I = 75 70
WALL COLOR : MEDIUM ROOF COLOR : MEDIUM
SER# 60215831 . 6
D .B .TEMP TOTAL TONS RSi 'TONS CF'M
1 . JUN AT 9 A.M. 75 . 6 1 . 56 1 . 27 692
2. JUL AT 9 A .M. 78 . 6 1 . 71 1 . 36 742
3. SEP AT 10 A.M. 75 . 4 1 . 76 1 . 49 811
4. OCT AT 2 P .M . 74 .0 1 . 90 1 . 67 908
5. SEP AT 3 P.M . 85 . 4 2 .40 2 . 02 1 , 102
6. JUL AT 4 P .M . 90.0 2 . 56 iA_ 1 , 142 <- -2- E-ZF
7. JUN AT 4 P.M. 87 . 0 2 . 42 2 .01 1 , 096
ZONE HEATING--> - 24 , 295 W/INFIL,- r-i-0 , 662D CFM =558
INP-UTS
ORIENTATION OF BUILDING N S W RF
TRANSMISSION FACTORS 0. 08 0 . 08 0 . 08 0 .00 0 . 08
GL F- .55 IS LI-FLO Y SHADE FACT=0. 3 NO . FLOORS _ 2
LENGTH - 24 WIDTH - 36 HEIGHT = 16 VA .= 7
OUTPUTS
NUMBER OF PEOPLE - 4 SENSIBLE PEO LE LOAD 980
TOTAL LIGHTS 2 , 160 LIGHTING LOA 9 , 215
OTHER ELECTRICAL - 432 OTHER ELECTR CAL 1 , 474
AREA OF N . GLASS - 65 NORTH GLASS OLAR 648
AREA OF S. GLASS - 65 SOUTH GLASS OLAR 1 , 305
AREA OF E . GLASS - 0 EAST GLASS SOLAR 0
AREA OF W. GLASS - 60 WEST GLASS SOLAR 5 , 198
TOTAL GLASS AREA - 190 TOTAL GLASS SOLAR 7 , 152
TOTAL GLASS AREA - 190 TOTAL GLASS TRANS . -1 , 567
AREA OF N . WALL 319 N . WALL LOAD 217
AREA OF S . WALL = 319 S . WALL LOAD 548
AREA OF E . WALL 576 E . WALL LOAD 571
AREA OF W. WALL 516 W . WALL LOAD 0
TOTAL WALL AREA - 1 , 730 TOTAL WAIL 'I ANS . 1 , 336
AREA OF ROOF 864 ROOF LOAD 2 , 205
SAFETY FACTOR 5% SAFETY B .T . 0 S 1 , 197
SUPPLY FAN H .P . -0. 33 FAN HEAT GAI - DT =1 , 003
VENTILATION CFM - 86 O .A . SENSIBLE LOAD =1 ,426
NUMBER OF PEOPLE - 4 PEOPLE LATENT LOAD = 820
VENTILATION CFM - 86 O.A . LATENT LOAD 2 , 379
TOTAL CFM-STD AIR- 1 , 142 TOTAL LATENT LOAD 3 , 199
ROOM SENSIBLE 25 , 127 ROOM LATENT 820
FLATS
GRAND TOTAL LOAD =30, 754 BTU ' S OR 2 . 56 T0N ' <--
LOAD RUN FOR # 6 . JUL AT P . M . -" lLfAREA (SQ FT) 1 , 728 SQ FT/TON 674
TOTAL CFM-STD AIR- 1 , 142 CFM/SO FT 0 . 66
HEATING LOAD
VENTILATION LOAD - 6, 368 ROOF HEATING LOAD 4 , 631
GLASS ALAI LUAU 7 ,001 WALL HEATING LOAD 6 , 508
INV 1 1 TR AT] ON LOAD= 6 , 108 WARM UP LOAD 748