Loading...
HomeMy WebLinkAboutBuilding 10 Arthur Drive (5)PERMIT # / Application For 6501 6111 1DEPARTMENTDECISIONHeatingPermitN0 c APPLICATION Is HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS cu N " IR APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR 0 a 3/19/85 Thomas P. D' Auria 00 O DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O &0 4a rn A C 1. LOCATION OF JOB AR)vkuiF -DR\VE r. i•. Cd C STR[[T y LOT NO. FLOOR APT. NO. o ON d d o aT R PN l2. OWNER W a O S. ADDRESS v Z"e II RS 1? U lod be 3 a.PHONE 4J JCn ' S. APPLICANT o Go B. ADDRESS L Cr- 19(6'Zy 7.PHONE w 'G B. LICENSE NO. 3 e,17-e 3 I~ w B. EXPIRATION DATE OF LICENSE O A to. ESTIMATED COST SCq Z 6 Cq 11. IS THIS A CONTRACT COST?13 YES MO bo y Ia. FEE ENCLOSED S Permit 1 4 0 7 x v Is. TYPE OF BUILDING: b RBID[MTU1L COMMERCIAL O G dcis ta. TYPE OF B.INDUSTRIAL ORIGINAL ALTERATI N INSTALLATION ADDITION REPAIR APPLICATION FOR HEATING PERMIT (Continu If it m Rev roe Side) 11. LOCATION OF JOB F NO. STREET S FLOOR AFT. NO. 12. TYPE OF INSTALLATION ElOIL BURNER EI-ELECTRIC ClVENTILATION SPRINKLER 0 GAS BURNER 0-STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. DESCRIPTION OF WORK 13. TO BE DONE: I S1Z// fN/wifeq Gi /j/s,T 44, c 4 CT LLi/ r flJTi/ 18. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS). Room SIZE B.T.U. B.T.U.AREA - SQUARE FEET z¢ °wNDWINDDWfDoorts VOLUME O <F DISTRIBUTION INSTALLED TOTAL TOTAL A LL ROOM L R N AND aW GROSS GLASS NET WALL CEILING FLOOR CU.FT. ATEA p' F COR T . TEOCTlD REGISTERf1, TYPE AHD SIZE RAD. OR LEADER SIZE < WALL to INFILT.) DIFF. F m N O. FT. FREE AREA 1 Get TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND 1s. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. DATE SIGNATURE OF LICANT MR-16 WALL TRANS 8 . 50 10. 80 12 . 40 16 . 12 21 . 45 23 . 75 19 . 41 10 . 04 31 . 90 WIND TRANS = 15 .00 O . D . D1i TFIML = 90 .0 O . D . WB TEMP = 74 . 0 SUN WIND.SOLAR 18 . 31 21 . 32 26 . 58 26 . 28 26 . 28 96 . 33 138 . 93 88. 16 99 . 33 BR-16 WALL TRANS 5 . 50 7 . 92 9 . 36 12 . 26 15 . 98 19 . 23 16 . 31 7 . 12 29 . 33 WIND TRANS 12 .00 O. D . DB TFMF = 87 .0 O . D . WB TEMP = 72 . 0 22 FLATS FLATS 06-06-1984 HARTFORD CONNECTICUT LAT = 4 2 ALT = 15 CONST- 70W/40R/ 70B ID= 75 70 WALL COLOR : MEDIUM ROOF COLOR : MEDIUM SER# 60215831 . 6 D .B .TEMP TOTAL TONS R, H 'TONS CFM 1 . JUN AT 9 A.M. 75 . 6 1 . 56 1 . 27 692 2. JUL AT 9 A .M . 78 . 6 1 . 71 1 . 36 742 3. SEP AT 10 A.M. 75 .4 1 . 76 1 . 49 811 4. OCT AT 2 P.M . 74 .0 1 . 90 1 . 67 908 5. SEP AT 3 P.M. 85 . 4 2 .40 2 . 02 1 , 102 6. JUL AT 4 P.M. 90.0 . , 2 . 56 10V 1 , 142 7 . JUN AT 4 P.M. 87 .0 2 . 42 2 . 01 1 , 096 ZONE HEATING--> = 24 , 295 W/INFIL- 30, 6 D CFM =558 INPUTS ORIENTATION OF BUILDING N S E W RF TRANSMISSION FACTORS 0. 08 0 . 08 0 . 08 0 .00 0 . 08 GL F- .55 IS LI-FLO Y SHADE FACT=0. 63 NO . FLOORS 2 LENGTH • 24 WIDTH = 36 HEIGHT = 16 VA .= 7 OUTPUTS NUMBER OF PEOPLE - 4 SENSIBLE PEOPLE LOAD = 980 TOTAL LIGHTS 2 , 160 LIGHTING LOAD 9 , 215 OTHER ELECTRICAL - 432 OTHER ELECTRICAL 1 , 474 AREA OF N . GLASS - 65 NORTH GLASS SOLAR m 648 AREA OF S . GLASS - 65 SOUTH GLASS SOLAR 1 , 305 AREA OF E . GLASS - 0 EAST GLASS SOLAR 0 AREA OF W. GLASS - 60 WEST GLASS SOLAR 5 , 198 TOTAL GLASS AREA - 190 TOTAL GLASS SOLAR 7 , 152 TOTAL GLASS AREA - 190 TOTAL GLASS TRANS . =1 , 567 AREA OF N . WALL - 319 N . WALL LOAF 217 AREA OF S . WALL 319 S . WAIL LOAF 548 AREA OF E . WALL = 576 E . WAIL LOAI 571 AREA OF W. WALL 516 W . WALL LOAI U TOTAL WALL AREA - 1 , 730 TOTAL WAIL IRANS . 1 , 336 AREA OF ROOF 864 ROOF LOAD 2 , 205 SAFETY FACTOR 5% SAFETY B .T . . S 1 , 197 SUPPLY FAN H .P . -0. 33 FAN HEAT GAIN - DT =1 , 003 VENTILATION CFM - 86 O .A . SENSIBLE LOAD =1 , 426 NUMBER OF PEOPLE - 4 PEOPLE LATENT LOAD = 820 VENTILATION CFM - 86 O. A . LATENI LOAD 2 , 379 TOTAL CFM-STD AIR- 1 , 142 TOTAL LATENI LOAD 3 , 199 ROOM SENSIBLE 25 , 127 ROOM LATENT 820 FLATS GRAND TOTAL LOAD =30, 754 BTU ' s OR 2. 56 TON_ <-- LOAD RUN FOR # 6 . JUL AT 4 P .M . t AREA (SQ FT) 1 , 728 SQ FT/'T0N 674 15 TOTAL CFM-STD AIR= 1 , 142 CFM/SQ FT 0 . 66 HEATING LOAD VENTILATION LOAD = 6 , 368 ROOF 11FATING LOAI)4 , 631 GLAS,, Ili:Al I.UAD 7 ,Ool WALL. HEATINC LOAD 6 , 508 TNi- I I TRATION I OAD= f) , 'i(IH WARM 111) LOAP 748