Loading...
HomeMy WebLinkAbout28 Abar Lane (14)FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: NO. TOWN OF SOUTH WINDSOR EST.COST: yy BLDC. PERMIT NO. lV`lk 1540 SULLIVAN AVENUE FEE •,y (® SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $1,000 - $10.00 1000 or fraction LOCATION OF BUILDING 1ji9 Q thereof - $10.00 A/ c!-,CiAW/Atk &- ., dkeck jerX a _ L.(nc.rpm 2C —a-2 93 OWNE ADDRESS TOWN PHONE NO. C r' der "lS% /'a.6 c, G2" HVAC CONTRACTOR ADDRESS PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE 6 MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE Z °F INSIDE°F DIFFERENCE A-' OF TOTAL HEAT GAIN (STUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE b MODEL TONNAGE COOLING CAPACITY (BTUH) U IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 6),Vc/C.- /T e,00 e2 7.-9G STATE LICENSE — NAME 6 TYPE # DATE SIGNATURE OF APPLICANT V 01— 00/4K APPROVED DATE 80 4A 11/88 I se B re R CALCULATION SHEET 1503 (Modern Method)COPYFight 1971 by The Hydionics institute WNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL. A COL.6 COL.C COL.D COL.E COL.F COL.G 1 ROOM S O H L I W H L W H L W H L W H L W Design Water Tamp. 2 ROOM DIMENSIONS, FT.U STUN per Foot of 3 LENGTH EXPOSED WALLS,FT.Radiation Selected WINDOW AND OUTSIDE DOOR AREA w STUN STUN STUN STUN STUN 5 WALL CONSTRUCTION ROOM LIN. FT.OF Table 9,Line 3 a HI TOTALS RADIATION 8 TYPE OF GLASS FROM LINE 12 SELECTED IBottom of table used for Line 51 7 CEILING CONSTRUCTION C 17 able 9.L it WI g FLOOR CONSTRUCTION? D ITable 9.L a W or Lin. F t 1 E 9 COLD PARTITION CONSTRUCTION F ITable 9,L a HI G 10 c 1 Wall IWlth Openingal O H 2 Wells(With Opaningal X 1 3 Wells IWith Openings) or Ent.Hall I. J 11 TOTAL BTUH AT 7OF TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K COL.A _ —_-_ COLS COL.H COL.I COL_J COL.K COL.L TOTAL BTUH TOTAL OF SUILDING RADIATION1ROOMQATSELECTED O H L r W H I L W N L W H I L I W H I L W DESIGN TEMP.• 2 ROOM DIMENSIONS.FT I- DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT. WINDOW AND OUTSIDE DOOR AREA LL STUN STUN BTUH BTUH BTUH S WALL CONSTRUCTION INCREASE BATHROOM ITable 9, Llne 3 a H) TOTAL 20% 6 TYPE OF GLASS bottom of table used lot Line 51 FOR CONCRETE FLOOR ON7CEILINGCONSTRUCTIONGROUNDORFILL ITable,9. L a W) GRADE LEVEL,USE LINEAR S FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE ITable 9.L a W or Lin Ft l 9 COLD PARTITION CONSTRUCTION ITable 9.L a HI 10 c 1 Wall(With Openings)O 2 Wells!With Openings) G XJ 3 Wens(With Openinga)or Ent. Han 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is araitable from The Hydronlcs Institute 36 Russo Place,6erkelay Heights,N J 01922 WEATHERTREND INC PROJECT: NEW LONDON TURNPIKE CLIENT: Pare GLASTONBURY, CONNECTICUT DATE:10/21 /9(, RESIDENTIAL/LIGHT COMMERICAL HVAC LOADS DESIGNER: RUSSELL DESIGN CONDITIONS: DESIGN PARAMETER SUMMER WINTER OUTDOOR DRY BULB TEMPERATURE 95 DEG.F 0 DEG.F INDOOR DRY BULB TEMPERATURE 70 DEG.F 75 DEG.F DESIGN TEMPERATURE DIFFERENCE 25 DEG.F 75 DEG.F INDOOR—OUTDOOR GRAINS DIFFERENCE 33 GRAINS OUTDOOR DAILY TEMPERATURE RANGE MED TOTAL BUILDING LOAD SUMMARY: BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAi DESCRIPTIONS QUAN LOSS GAIN GAIN GAIT' 1—A WIND. CLEAR GLASS WOOD FRAME 207 15, 372 0 17, 163 17, 16. 12—C WALL R-11 + 1 /2" GYPSUM(R-0 . 5 ) 858 5, 793 0 2, 207 2120-' 10—D DOOR WOOD SOLID CORE 63 2, 175 0 828 82F,, 16—C CEILING R-11 INSULATION 1 , 062 7, 008 0 4, 578 4, 57F 19—B FLOOR/ENCL CRAWL HARDWD + R-11 1 , 062 3, 186 0 0 SUBTOTALS FOR STRUCTURE: 3, 252 33, 534 0 24, 776 24, 77( PEOPLE 3 0 690 900 1 , 59G APPLIANCES 0 0 0 300 300 DUCTWORK 0 0 0 0 INFILTRATION W.CFM: 226 . 6 S .CFM: 70 .8 0 18, 691 1 , 589 1 , 947 3, 536 VENTILATION W.CFM: 0 . 0 S .CFM: 0. 0 0 0 0 0 SENSIBLE GAIN TOTAL 27, 923 TEMP. SWING MULTIPLIER X 1 . 00 BUILDING LOAD TOTALS 52, 225 2, 279 27 , 923 30, 20", SUPPLY CFM AT 20 DEG DT: 1 , 269 CFM PER SQUARE FOOT: 1 . 19` SQUARE FT. OF ROOM AREA: 1 , 062 SQUARE FOOT PER TON: 421 . 95(l TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: 2 . 517 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS . RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE WEATHERTREND INC GLASTONBURY, CONNECTICU' 10/21 /96 PAGE ROOM LOAD SUMMARY RM ROOM AREA ------ HEATING ------ ------ COOLING -- NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFN 1 . LIVING ROOM 264 14, 610 28 . 0 190 8, 070 28 . 9 36i 2 . TV ROOM 120 3, 743 7 . 2 49 2, 187 7 .8 9(-, 3 . BED ROOM 144 6, 781 13 . 0 88 3, 773 13 . 5 17-- 4. BATH ROOM 60 1 , 721 3. 3 22 620 2 . 2 2 5 . BED ROOM 2 168 7, 120 13. 6 92 3, 618 13 . 0 16/: 6 . BATH/BACK ENTRY 42 2, 818 5 . 4 37 698 2 . 5 3--_ 7 . KITCHEN/DINING 264 15, 432 29 . 5 200 8, 955 32 . 1 407 ROOM TOTALS 1 , 062 52, 225 100 . 0 678 27, 921 100. 0 1 , 26, RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ****** WEATHERTREND INC GLASTONBURY, CONNECTICU' 10/21 /96 PAGE DETAILED ROOM LOADS ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAI'w 1 . LIVING ROOM 12. 0 WID X 22 . 0 LEN = 264 SF CEIL.HT = 8 . G S -WALL-12C 8 X 12 96 0. 090 6 . 8 648 2. 6 0 247 W -WALL-12C 8 X 22 95 0. 090 6. 8 641 2 . 6 0 245 W -DOOR-10D 7 X 3 21 0 . 460 34. 5 725 13 . 2 0 27(, W -GLAS-lA 1-P 0-1 S-1 O%S 60 0 . 990 74. 3 4, 455 93 . 0 0 5 , 58C CEIL-16C DARK 22 X 12 264 0. 088 6 . 6 1 , 742 4. 3 0 1 , 138 FLOOR-19B 22 X 12 264 0 . 040 3 . 0 792 0 . 0 0 C INFILTRATION W: 68. 0 S: 21 . 0 81 69 . 2 5, 607 7 . 2 477 584 ROOM TOTALS 14, 610 477 8, 07, 2 . TV ROOM 12. 0 WID X 10 . 0 LEN = 120 SF CEIL.HT = 8 . 0 W -WALL-12C 8 X 10 65 0 . 090 6.8 439 2. 6 0 16`; W -GLAS-lA 1-P 0-1 S-1 O%S 15 0 .990 74. 3 1 , 114 93. 0 0 1 , 39` CEIL-16C DARK 10 X 12 120 0. 088 6 . 6 792 4. 3 0 51r,1 FLOOR-19B 10 X 12 120 0 . 040 3 . 0 360 0 . 0 0 C INFILTRATION W: 13 . 0 S : 4. 0 15 69 . 2 1 , 038 7 . 2 88 10L ROOM TOTALS 3, 743 88 2, 18" 3 . BED ROOM 12 . 0 WID X 12 . 0 LEN = 144 SF CEIL.HT = 8 . (` W -WALL-12C 8 X 12 81 0. 090 6 .8 547 2 . 6 0 20z N -WALL-12C 8 X 12 81 0 . 090 6 . 8 547 2 . 6 0 20,'- W -GLAS-lA 1-P 0-1 S-1 O%S 15 0 . 990 74. 3 1 , 114 93 . 0 0 1 , 39_: N -GLAS-lA 1-P 0-1 S-1 100%S 15 0 . 990 74. 3 1 , 114 35 . 0 0 527 CEIL-16C DARK 12 X 12 144 0 . 088 6 . 6 950 4. 3 0 621 FLOOR-19B 12 X 12 144 0 . 040 3 . 0 432 0 . 0 0 C INFILTRATION W: 25 . 0 S: 8 . 0 30 69 . 2 2, 077 7 . 2 177 21 PEOPLE 2 230 300 460 60( ROOM TOTALS 6, 781 637 3, 77_ RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ****** WEATHERTREND INC GLASTONBURY, CONNECTICU- 10/21 /96 PAGE DETAILED ROOM LOADS ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIT\ 4 . BATH ROOM 10. 0 WID X 6 . 0 LEN =60 SF CEIL.HT = 8 . (. N -WALL-12C 8 X 6 42 0. 090 6. 8 284 2. 6 0 10z N -GLAS-1A 1-P 0-1 S-1 100%S 6 0. 990 74. 3 446 35 . 0 0 21 ' CEIL-16C DARK 6 X 10 60 0 . 088 6 . 6 396 4. 3 0 25" FLOOR-19B 6 X 10 60 0 . 040 3 . 0 180 0. 0 0 INFILTRATION W: 5 . 0 S : 2. 0 6 69 . 2 415 7 . 2 35 41 ROOM TOTALS 1 , 721 35 62' 5 . BED ROOM 2 14. 0 WID X 12 . 0 LEN = 168 SF CEIL.HT = 8 . (-- N -WALL-12C 8 X 12 81 0 . 090 6 . 8 547 2 . 6 0 20,P E -WALL-12C 8 X 14 97 0 . 090 6 . 8 655 2 . 6 0 25' N -GLAS-1A 1-P 0-1 S-1 100%S 15 0 .990 74. 3 1 , 114 35 . 0 0 5211: E -GLAS-1A 1-P 0-1 S-1 O%S 15 0. 990 74. 3 1 , 114 93. 0 0 1 , 39` CEIL-16C DARK 12 X 14 168 0. 088 6 . 6 1 , 109 4. 3 0 72,' FLOOR-19B 12 X 14 168 0 . 040 3 . 0 504 0 . 0 0 INFILTRATION W: 25 . 0 S: 8. 0 30 69 . 2 2, 077 7 . 2 177 211_ PEOPLE 1 230 300 230 30c.' ROOM TOTALS 7, 120 407 3, 61 ,' 6 . BATH/BACK ENTRY 6 . 0 WID X 7 . 0 LEN =42 SF CEIL.HT = 8 . 0 E -WALL-12C 8 X 7 35 0 . 090 6 . 8 236 2 . 6 0 9C E -DOOR-10D 7 X 3 21 0 . 460 34. 5 725 13 . 2 0 27( CEIL-16C DARK 6 X 7 42 0. 088 6 . 6 277 4. 3 0 18 FLOOR-19B 6 X 7 42 0. 040 3 . 0 126 0 . 0 0 INFILTRATION W: 18 . 0 S : 5 . 0 21 69 . 2 1 , 454 7 . 2 124 15 ; ROOM TOTALS 2, 818 124 69. RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ****** WEATHERTREND INC GLASTONBURY, CONNECTICU' 1 0/21 /96 PAGE DETAILED ROOM LOADS ITEM AREA -U-HTG SEN. CLG LAT. SEN . DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIP, 7 . KITCHEN/DINING 12. 0 WID X 22 . 0 LEN = 264 SF CEIL.HT = 8 . k E -WALL-12C 8 X 22 110 0 . 090 6 . 8 743 2 . 6 0 28- S -WALL-12C 8 X 12 75 0 . 090 6 . 8 506 2 . 6 0 19- S -DOOR-10D 7 X 3 21 0 . 460 34. 5 725 13. 2 0 27 . E -GLAS-1A 1-P 0-1 S-1 OAS 60 0 . 990 74. 3 4, 455 93 . 0 0 5 , 58C E -GLAS-1A .1-P 0-1 S-1 OAS 6 0 . 990 74. 3 446 93 . 0 0 55 CEIL-16C DARK 22 X 12 264 0. 088 6. 6 1 , 742 4. 3 0 1 , 13 FLOOR-19B 22 X 12 264 0 . 040 3 . 0 792 0 . 0 0 INFILTRATION W: 73 . 0 S : 23 . 0 87 69 . 2 6, 023 7 . 2 512 62' APPLIANCES 0 30+ ROOM TOTALS 15, 432 512 8, 95 -