HomeMy WebLinkAbout21-24W 42 Windshire Dr Min Imp ApprovalERTIFIED
C
Timothy Goodale
321 Talcottville Rd.
Vernon, CT 06066
April 29, 2021
RE: Appl. #21-24W, Goodale — 42 Windshire Dr., South Windsor, CT. RR Rural Residential Zone
Dear Mr. Goodale:
The Inland Wetlands Agency/Conservation Commission, through staff has approved minimal impact
application Appl. #21-24 W, Goodale — 42 Windshire Dr, South Windsor, CT - Inland
Wetland/Conservation Commission minimal impact application for the construction of an in -ground pool
and associated grading within the upland review area at 42 Windshire Dr. (Assessor's Map #102, lot
#67). This approval is subject to the following conditions:
1. The application shall indemnify and hold harmless the Town of South Windsor against any liability,
which might result from the proposed operation or use.
2. The permit is valid for five years and shall expire on April 29, 2025. It is the
landowner(s)/applicant(s) responsibility to track expiration dates and notify the Commission of a
renewal request at least 65 days prior to expiration.
3. Perimeter erosion controls must be installed prior to construction.
4. All additional approvals required must be obtained and submitted prior to any activity on the site.
5. The applicant shall cause notice of the decision to be published in a daily newspaper having a
general circulation in the Town. The notice must be published within ten (10) days of receipt of
the decision. The applicant must notify the Planning office of the date of publication and fax
or mail a copy of the published legal notice. Appeal of this decision may be brought to the
Agency within fifteen (15) days after the publication date of the notice.
Very truly yours,
frJ�Y ey H. F Environmental Planner
INLAND WETLANDS AGENCY/
CONSERVATION COMMISSION
cc: Inland Wetland/Conservation Commission
Director of Planning
Chief Building Official
Town Hall 1540 Sullivan Avenue. South Windsor. CT 06074 1 Tel (860) 644-2511 1 Fax (860) 644-3781
TO BE PUBLISHED IN THE JOURNAL INQUIRER
SOUTH WINDSOR — INLAND WETLANDS AGENCY/CONSERVATION COMMISSION
A minimal impact application was approved by the South Windsor Inland Wetland Agent
for:
Application Appl. #21-24W, Goodale — 42 Windshire Dr., South Windsor, CT. — Inland
Wetland/Conservation Commission minimal impact application for the construction of an
in -ground pool and associated grading within the upland review area of an adjacent
wetland area. (Assessor's Map 102, Lot 67).
`ro
V
L
m
cn
Q
0
QQ
0
N
�r
ro
m
J
<t
0
N
N
0
a_
I
0
m
on
CD
T
Q
L
m
NT
CA
NT
I
i
00
m
QO
O
(J
0
iL
LEGEND
EXISTING
DESCRIPTION
BORINGS
TP
BORING / TEST PIT LOCATION
COMMUNICATION
cx
OVERHEAD COMM. LINES (CABLE, TEL, ETC.)
- - cx - -
- cx -
APPROX. UNDERGROUND COMMUNICATION LINES
CONTROL POINTS
BENCHMARK
DOMESTIC WATER
- - - Wx - -
- wx -
APPROX. WATER MAIN
- - - Wsx - -
- Wsx -
APPROX. WATER SERVICE
D4
WATER VALVE
FIRE HYDRANT
LIGHTING
POLE MOUNTED LIGHT
NATURAL GAS
GAS VALVE
- - - Gx - -
- Gx -
APPROX. GAS MAIN
- - - Gsx - -
- Gsx -
APPROX. GAS SERVICE LINE
POWER
EOx
ELECTRICAL LINES, OVERHEAD
- - - EUx - -
- EUx -
APPROX. ELECTRICAL LINES, UNDERGROUND
CO-)
UTILITY POLE
`9b
UTILITY POLE WITH LIGHT
UTILITY POLE WITH TRANSFORMER
PROPERTY
- -
PROPERTY LINE
EASEMENT LINE
O
IRON PIPE
®
IRON ROD
MONUMENT
ROADS
GUARD RAIL
-�- OR
SIGN
SITE FEATURES
, • •
EDGE OF WATER
x - x x
x
BARBED WIRE FENCE
-o o o
o
CHAIN LINK FENCE
RAIL FENCE
-
0
STOCKADE FENCE
+ + +
+
WIRE FENCE
STONE WALL
(B OR
TREE
TREE LINE
SANITARY SEWER
- - - sx - -
- sx -
APPROX. SANITARY SEWER MAIN
- - - ssx - -
- ssx -
APPROX. SANITARY SEWER SERVICE LINE
OOo
SANITARY SEWER MANHOLE
Ov
SEWER CLEAN OUT
STORM SEWER
- -- ---
-
APPROX. STORM DRAIN PIPE
OO
STORM DRAIN MANHOLE
®
CURB INLET
❑
CATCH BASIN
TOPOGRAPHY
-----95-----
CONTOUR
X 61.95
SPOT ELEVATION
WETLANDS
® ®
WETLANDS LINE
z
LO
cv
i
�12 MIN
r - 6" THICK LAYER OF RIP RAP
CONSISTING OF SOUND, TOUGH„
DURABLE. AND ANGULAR ROCK,
- PLACED OVER GEOTEXTILE. MAXIMUM
- RIPRAP SIZE TO BE 4 INCHES AND
NOT MORE THAT 10% LESS THAN 2
INCHES.
r
-' NOTES:
1. INSPECT CONSTRUCTION EXIT WEEKLY
AND AFTER EVERY MAJOR STORM EVENT
2. WASH WATER, IF USED SHALL BE
DIRECTED 'TOWARDS A SEDIMENT SIZED
FOR SITE CONDITIONS.
3. STONE SHALL BE REMOVED/REPLACED
WHEN EXCESS LEVELS OFMUD ARE
{ OBSERVED.
CONSTRUCTION ENTRANCE
N.T.S.
1. SET POSTS & EXCAVATE A 6"x6"
TRENCH UPGRADIENT OF POSTS.
ANGLE POSTS
5' UPGRADIENT
95' 12"
-- ._ E
2. STAPLE GEOTEXTILE TO POSTS.
GEOTE)
3. EXTEND GEOTEXTILE INTO TRENCH. 4. BACKFILL TRENCH AND
COMPACT EXCAVATED SOIL
GEOTE)
CONC. MON. DISC S .
ii10
4=1502'13"
R= 47,7 31
\: L=125 27'
I. R. . 5/N
LC=N79 06 57"W C
\ 24.91 ' PROPOSED
CONSTRUCTION
ENTRANCE
)MPACTED BACIo
SILT FENCE
N.T.S.
""sue.■�� (� l R. 518IN
__ 4=803824"
- - - R=25.00'
L=35.33'
® LC=N493021 "W
0 10' EASEMENT IN FA VOR 32.46'
OF THE CONNECTICUT LIGHT CONC MON. DISC
LANDSCAPE &POWER COMPANY CONC. MON. DISC
AREA (TYPICAL) (SEE MAP REF: #2)
Nlf I -17" MAPLE
JOSEPH L OUIS KORO RE JR. I
(VOL. 2821 PG 90)
�. -� �- LANDSCAPE .
AREA (TYPICAL)
NIF 50-F�
MICHAEL J. ZUBRETSKY
(VOL. 1137 PG 274)
CONC. MON X -j /, R. 51SIN
APPROX. �. I
L 0CA TION
DRAIN PIPE
0,
x
- - 4 2a4.r EXISTING HOUSE 1
FF' 247 22
FF GAR: 245.48 I
FF BSM7 NIF
WALKOU;: 238.56 0 ' TOWN OF SOUTH WINDSOR
lz p a x `� PROPOSED co
2 qT� at`
POOL EQUIP. No N �
., EX. YD '
v"
r1� ko stjO TF- 238. 12 g
3
'�?47.O x
r
�' x 23D.2 {�•' X� q� 'R` dy
x 240.5
9 La. 240. 240.7`
x 237.7 `.' i � FIRE -PIT ->: � ',., ��i� x 240.7
0 PROPOSED
Q--`FENCE
--- - 3'I
1'RQPOSED o 6,f 10' EASEMENT IN FA VOR
OF THE CONNECTICUT LIGHT
+0 POOL,,,_�� & POWER COMPANY
a
(SEE MAP REF. #2)
/
S._ ETBAC'K FOR POOLS
�_ - I
WF 9
0 0
WF 8 WF 7 0
- NOTE. THE LOCATION OF UNDERGROUND
PROPOSED
SILT FENCE ,.,� � .� �� �-- WATER AND ELECTRIC LINES ASSOCIATED
® ' WITH THE WELL ARE TO BE DETERMINED
Goo amWELL
AND RELOCATED AS NECESSARY PRIOR
� s.. ;.� 9 �� I
� won - TO THE START OF ANY POOL
x 2J7.3 '` CONSTRUCTION
4 .UM mom = 261. 74
-'--__ 585,,32'2a E '*\-13" MAPL I
WF 6 18" MAPLEow
WF 1
WF 5 -- CONC MON. X
1 CONC. MON X
�YUF 4 238,
N/F
TOWN OFSOUTH WINDSOR
(1/01. 319 PG 143)
24 " OAK
8,OAK
WF 3
WF 2
NO TES:
1. PROP/;RTY IS IN THE AA-30 ZONE.
2. PARC11- CONTAINS 42,855 SQUARE FEET OR 0. 983 ACRES
J. HORIIONTAL DATUM IS BASED ON NAD83. INERT/CAL DATUM IS BASED ON
NA V988.
4. PROPI RTY DOES NOT FALL WITHIN THE LIMITS OF A SPECIAL FLOOD
HAZARD ZONE AS DEPICTED ON- 'FIRM FLOOD INSURANCE RA TE MAP
NUMHI:R 0900JCOJSIF TOWN OF SOUTH WINDSOR CONNECTICUT HARTFORD
COON I PANEL J81 OF 615 COMMUNI TY NUMBER 090036 EFFECTIVE DA 7E:'
SEPT 26, 2008 FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL
INSUIi'ANCE ADMINISTRA TION.
5. UNDL&GROUND UTILITY, STRUCTURE AND FACILITY LOCATIONS DEPICTED
AND NOTED HEREON HA VE BEEN COMPILED, IN PART, FROM RECORD
MAPPING SUPPLIED BY THE RESPECTIVE UTILITY COMPANIES OR
GOVE&NMENTAL AGENCIES, FROM PAROL TESTIMONY AND FROM OTHER
SOU& CFS THESE L OCA TIONS MUST BE CONSIDERED AS APPROXIMA TE IN
NA TUPE ADDI TIONALL Y, OTHER SUCH FEA TURFS MA Y EXIST ON THE SI TE,
THE 1 XISTENCE OF WHICH ARE UNKNOWN TO DESIGN PROFESSIONALS, INC
THE :>IZE, LOCH TION AND EXISTENCE OF ALL SUCH FEA TURFS MUST BE
FIELD DETERMINED AND VERIFIED BY THE APPROPRIATE AUTHORITIES PRIOR
TO CONSTRUCTION.
6. CONIRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" FOR UNDERGROUND
UT/LIIY MARKING AT LEAST TWO FULL WORKING DAYS PRIOR TO START OF
CONS IRUCT/ON: 1-800-922- 4455 OR WWW. CB YD. COM.
7. SIDEWALK TO BE REPAIRED AND OR REPLACED IF DAMAGED DURING TIME
OF POOL CONSTRUCTION.
8. WETLANDS DEPICTED HEREON ARE AS FIELD DELINEATED BY JMM WETLAND
CONSULTING SERVICES, LLC AND LOCATED BY DESIGN PROFESSIONALS, INC.
OF CONNp
\A. JAM'••
•o'��:, 33459
MAP REFERENCES:
1. PLOT PLAN "WINDSHIRE ABBE ESTATES, LTD" SOUTH WINDSOR, CONNECTICUT DEVELOPED
BY WINDSHIRE ABBI ESTA TES ASSOCIA TES SOUTH WINDSOR, CONNECTICUT DEVELOPED BY
WINDSHIRE ABBE ES IA ITS ASSOCIA ITS DA TE 9-18-81 SCALE 1 " = 40' SHEET NO. 3 OF
13 PREPARED BY f USS & 0 NEILL.
2 CL &P EASEMENT ON PROPER TY KNOWN AS "WINDSHIRE ABBE ES TA TES, L TD "
TOWN OF SOUTH WINOSOR DATE 3-16-82 SCALE 1 "=40' DWG. NO. E-N-KO5EI-0724
PREPARED BY THE CONNECTICUT LIGHT & POWER COMPANY.
SURVEY NOTES.•
1. THIS SURVEY AND MAP HAS BEEN PREPARED PURSUANT TO THE REGULA TIONS OF
CONNECTICUT STATE AGENCIES SECTIONS 20-300b-1 THRU 20 300b-20 AND THE
"STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS
ADOPTED BY THE CJNNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. ON
SEPTEMBER 26, 1996
• TYPE OF SURVI Y IS AN IMPROVEMENT LOCATION SURVEY - PROPOSED AND /S
INTENDED TO UIPICT THE LOCATION OF EXISTING AND PROPOSED CONDITIONS
RELATIVE TO PFDPERTY LINES.
• THIS IS A RESUIr VEY BASED ON MAP REFERENCE #1.
't GO!�t�;'�,i HORIZONTAL ACCURACY MEETS CLASS A-2 STANDARDS. VERTICAL ACCURACY
� w'sro •
l CaL"A�.,� MEETS CLASS V 2 STANDARDS TOPOGRAPHY MEETS CLASS T-2 STANDARDS
Y , J , +l
QD t
?l gyp. kn a
...m
Y
i
& u s L A WRENCE R. GEIS:SL.ER, JR. L. S.
12327
LIC NO.
LU N V F- U. E
iR-10 0 , , $ �
CxO'nin y
>-O NN cd W
L m co co c
Li t0V°`O,y �C>
L Cl: ce N N w M W
- 000
N N
0 co co r- V
3 D W4
z
r� a a
0 ; dv
(n o w
c
y cca
W J
W
z�
oWw
v J
= y �_
� a
�� y F- w
y W Goo
ai c
O
oa C.LO
0 Q H
OL 0 L O V
Q L m
L 0 L L
_v i, L O
CL _C 4 �
Lu d OL C C
CL N O ?�
o N
D
0
N r
O I m
F 0
w M w N 3 Q u V
•o Q = s
a V o 0 0 1 J
E-
ZV_
H
Lu
> J Z C)Z
�0
a.
J v)o
®o
O N
O "
a
0
r
m
z
0
LL1
ry
L
O
z
Q 0
W
Z ZO
W O a
W
O L) o. N
M O
aJWO
J b
Q n
V
SHEET
V-1