Loading...
HomeMy WebLinkAbout7D 31759AT-plotGround Floor 4'7 1/2"38'10'22'13'18'3'6"7'11"5'7'11"13'8" 22' 1'6" 2'5'2"2'1'6"7'8"14'2"21'4"13' 4'2"4'6 1/2"13'7"4'3 1/2"3'9 1/2"14'3"9'3"9'3"9'3"8'8"8'8"RFPI-40's 2-1/2" x 11-7/8" @ 16" O.C.RFPI-80's 3-1/2" x 16" @ 16" O.C.RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8" RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8" RimBoard 1-1/8" x 11-7/8" Floor System Based on a Truss Roof Design All Materials and Dimensions Must be Verified by Contractor LVL Under Island LVL Under Island LVL Under Island J12 J7J11 J5 J4 @ 16"3 X J43 X J4J4 @ 16"J4 J4 J7 J1 2 X J6J7 J52 X J5J7 J2 @ 16"J1 @ 16"J1 J10 @ 16"3 X J8J9 3 X J8J2 @ 16"J7 F11 -1 F11 -1 F11 -1 D4 -2D3 -2 D5 -2D2 -3D1 -3F2 -2 F1 -2F1 -2F10 -3 FL(lb):8891 FL(lb):25522 FL(lb):22025 FL(lb):21819 FL(lb):23666FL(lb):12115 BLK1 (RFPI 80S -11.875")BLK1 (RFPI 80S -11.875")BLK1 (RFPI 80S -11.875")H1H1 H1H1H4 H8Ground Floor Design Method ASD (USA) Building Code IBC/IRC 2015 Floor Loads Live 40 Dead 15 Deflection Joist LL Span L/480 TL Span L/360 LL Cant 2L/480 TL Cant 2L/360 Deflection Girder LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Decking Decking SPF Plywood 3/4 APA Rated Sturd-I- Floor Fastener Nailed & Glued Ground Floor I Joist Qty Label Description Width Depth Length 30 J4 RFPI 40S 2.5 11.875 14-0-0 12 J10 RFPI 80S 3.5 11.875 44-0-0 1 J9 RFPI 80S 3.5 11.875 40-0-0 6 J8 RFPI 80S 3.5 11.875 26-0-0 11 J2 RFPI 80S 3.5 11.875 22-0-0 7 J1 RFPI 80S 3.5 11.875 18-0-0 1 J12 RFPI 80S 3.5 11.875 12-0-0 5 J7 RFPI 80S 3.5 11.875 8-0-0 2 J6 RFPI 80S 3.5 11.875 6-0-0 4 J5 RFPI 80S 3.5 11.875 4-0-0 1 J11 RFPI 80S 3.5 11.875 2-0-0 LVL/LSL Qty Label Description Width Depth Length 3 D2 2.0E Rigidlam LVL 1.75 11.875 40-0-0 3 D1 2.0E Rigidlam LVL 1.75 11.875 28-0-0 3 F10 2.0E Rigidlam LVL 1.75 11.875 22-0-0 2 D4 2.0E Rigidlam LVL 1.75 11.875 22-0-0 2 F2 2.0E Rigidlam LVL 1.75 11.875 22-0-0 3 F11 2.0E Rigidlam LVL 1.75 11.875 16-0-0 2 D3 2.0E Rigidlam LVL 1.75 11.875 14-0-0 2 D5 2.0E Rigidlam LVL 1.75 11.875 10-0-0 4 F1 2.0E Rigidlam LVL 1.75 11.875 4-0-0 Rim Board Qty Label Description Thickness Depth Length 18 R1 Common Rim Board 1.125 X 11.875 1.125 11.875 12-0-0 Blocking Qty Label Description Width Depth Length 1 BLK1 RFPI 80S 3.5 11.875 50-0-0 Hanger Qty Label Description Girder Supported Mbr. 4 H1 HU412 (Max)22 16d 10 10d 3 H4 MIT411.88 4 16d 4 10dx1 1/2 3 H8 ITS3.56/11.88 2 10dx1 1/2 Decking Qty Description 63 Sheets 3/4" SPF Plywood Project 7D 31759AT Seven D Wholesale 145 Dividend Rd. Rocky Hill, CT 1-800-800-6894 Created May 04, 2020Project7D 31759ATBuilder's Project198 Smith ST South Windsor CTShipping198 Smith STSouth Windsor CTEWP Studio Version 19.72.205 Powered by iStruct EWP StudioSimpson Strong-Tie®Component Solutions This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them Second Floor 4'7 1/2"38'10'13'18'3'6"7'11"5'7'11"13'8" 13'22' 1'6" 2'5'2"2'1'6"7'8"14'2"22'21'4"Open To Below Open To Below Open To BelowFloor System Based on a Truss Roof Design All Materials and Dimensions Must be Verified by Contractor RFPI-40's 2-1/2" x 11-7/8" @ 16" O.C.RFPI-80's 3-1/2" x 11-7/8" @ 16" O.C.RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"RimBoard 1-1/8" x 11-7/8"J4 @ 16"J32 X J3J1 @ 16"J2 @ 16"J1 J2 F6 -3D8 -2 D9 -2 F3 -2F9 -2F8 -2 F7 -2 F1 -2F5 -3F4 -3FL(lb):7815 FL(lb):2979 FL(lb):376 FL(lb):17093BLK1 (RFPI 80S -11.875")H7H6H7H6H7H5H2 H7 H6H5H7 H6Second Floor Design Method ASD (USA) Building Code IBC/IRC 2015 Floor Loads Live 40 Dead 15 Deflection Joist LL Span L/480 TL Span L/360 LL Cant 2L/480 TL Cant 2L/360 Deflection Girder LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Decking Decking SPF Plywood 3/4 APA Rated Sturd-I- Floor Fastener Nailed & Glued Second Floor I Joist Qty Label Description Width Depth Length 12 J4 RFPI 40S 2.5 11.875 14-0-0 3 J3 RFPI 40S 2.5 11.875 8-0-0 29 J2 RFPI 80S 3.5 11.875 22-0-0 12 J1 RFPI 80S 3.5 11.875 18-0-0 LVL/LSL Qty Label Description Width Depth Length 2 D8 2.0E Rigidlam LVL 1.75 9.5 10-0-0 2 D9 2.0E Rigidlam LVL 1.75 9.5 6-0-0 3 F5 2.0E Rigidlam LVL 1.75 11.875 18-0-0 3 F4 2.0E Rigidlam LVL 1.75 11.875 16-0-0 2 F3 2.0E Rigidlam LVL 1.75 11.875 14-0-0 2 F9 2.0E Rigidlam LVL 1.75 11.875 10-0-0 2 F8 2.0E Rigidlam LVL 1.75 11.875 8-0-0 2 F7 2.0E Rigidlam LVL 1.75 11.875 6-0-0 2 F1 2.0E Rigidlam LVL 1.75 11.875 4-0-0 3 F6 2.0E Rigidlam LVL 1.75 16 20-0-0 Rim Board Qty Label Description Thickness Depth Length 11 R1 Common Rim Board 1.125 X 11.875 1.125 11.875 12-0-0 Blocking Qty Label Description Width Depth Length 1 BLK1 RFPI 80S 3.5 11.875 42-0-0 Hanger Qty Label Description Girder Supported Mbr. 1 H2 HGUS5.50/12 56 16d 20 16d 19 H5 ITS3.56/11.88 2 10d 22 H6 ITS2.56/11.88 2 10d 5 H7 HU412 (Min)16 16d 6 10d Decking Qty Description 42 Sheets 3/4" SPF Plywood Project 7D 31759AT Seven D Wholesale 145 Dividend Rd. Rocky Hill, CT 1-800-800-6894 Created May 04, 2020Project7D 31759ATBuilder's Project198 Smith ST South Windsor CTShipping198 Smith STSouth Windsor CTEWP Studio Version 19.72.205 Powered by iStruct EWP StudioSimpson Strong-Tie®Component Solutions This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them Roof D7 -3 D6 -3FL(lb):14300 H3 Roof Design Method ASD (USA) Building Code IBC/IRC 2015 Floor Loads Live 40 Dead 15 Deflection Joist LL Span L/480 TL Span L/360 LL Cant 2L/480 TL Cant 2L/360 Deflection Girder LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Decking Decking SPF Plywood 3/4 APA Rated Sturd-I- Floor Fastener Nailed & Glued Roof LVL/LSL Qty Label Description Width Depth Length 3 D6 2.0E Rigidlam LVL 1.75 14 18-0-0 3 D7 2.0E Rigidlam LVL 1.75 16 22-0-0 Hanger Qty Label Description Girder Supported Mbr. 1 H3 HGUS5.50/14 66 16d 22 16d Project 7D 31759AT Seven D Wholesale 145 Dividend Rd. Rocky Hill, CT 1-800-800-6894 Created May 04, 2020Project7D 31759ATBuilder's Project198 Smith ST South Windsor CTShipping198 Smith STSouth Windsor CTEWP Studio Version 19.72.205 Powered by iStruct EWP StudioSimpson Strong-Tie®Component Solutions This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them