Loading...
HomeMy WebLinkAbout24 Arrowwood Circle (9)PERMIT v DEPARTMENT DECISION Application For k R9 7HeatingPermit A"MATION IS MENEM. DWARTMF r OF I.ICENSF:S AND INSPWrIONS O AFFRovEo C1 asAKRovED TOWN OF SOUTH WIN DSOR QM+ man cow limcum A//MAmm MYOT OC PROUD M "NO. stem MIiN mums on KLN A 1. LOCATNNI Of JOB I g Z(Z u)c,1Ul1J #C:v , l2CLt DR.fTRSR QLOT Ilf. PLO" AM IN. ag f. OWNER O 11 n n f. ADDRESS `f ") Rn u u1Or) 0 !:, S 0l V\ L t r 4.MONK Vl f. AMMJCANT I 4. ADDRESS . i , 1.PNONs LICENSE NO.3 1 RL D. E7IMRATION DATE Of UCENSE 10. [STIMATED COST 11. a TNNI A CONTRACT COM TEf 3 w is. m ENCLO/ED f--7 0c R PC R amo iA7n u i w2 ! 1 f. TTrE OF 111RL01" 1p 16 S 8S women" CONNIK AL v 94. TTPE O/ JON: INDUSTRIAL ORIGINAL ALTERATIONINSTALLATIONADDITION a[!AI! APPLICATION FOR HEATING PERMIT xww wa fnm mow.. m&) 11. LOCATION OF t0. iTtt[T Foot YT.NO. 1s TTPE OF INSTALLATION: OIL BURNER ELECTRIC uvm mm SPRINKLEW GAS B man srAcK INCINERAToR mm LLANEous Add ,)/) p Mawr" I& OF TANK NK OFFILL T 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT IIONNET FIRI RATE BOILER OR FURNACE MAKE AND NO. B.T.U.OR SQ. FT. NET B.T.U. OR SQ. FT4;FWNG RATE FLOORS TO BE HEATED EW R OLD BUILDING INSULATED R NO TYPE OF WALL INSULATI ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.UJSQ.,FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0 FAHRENHEIT MAKE OF RADIATIOM_ =PER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DUMPMN Of WORK Cf I se-, Sriit. TO BE DONE• LL---- 1s. NEAT LOU SCHEDULE. (TO BE INCLUDED FOR ALL JOBSI: IINOII Nis gets ANO 00011 ARIA - SGUMR RttT W06 N.T.IL N.T.Y. TsrAm. Tw^6 OIiTNINNTION INITALLiD i IIOOY ssi NAB OVA= NR N MN ALA CY./T. AT w I AN. ""wren L N N use i BALL f IN/ILTJ ?cup TO : TTAN AND Nif 10. . M LNAOp i FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.UJHR B. DOMESTIC HOT WATER DEMAND B.T.UJHR `J C. PIPING. OTHER THAN NORMAL B.T.UJHR ALLOWANCE FOR HEAT VALVE OF FUEL (A B CI FACTOR 17. ELECTRICAL WORK BY• 11"s AtttLY tt. THEIR RS AND ALL WORK COVERED BY THIS APPUCATION HAS BSI AUTHORIZED BY THE (OWNER) OR ( MIY AND Will BE DONE IN STRICT ACCORDANCE WITH THE BUI CODE 2PLICATI N TO BE COMPLETELY FILLED IN. / / 7 B= R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronlcs Institute OWNER ADDRESS Z DESIGN TEMPERATURE DIFFERENCE F. DATE - COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOMir D H L W H L W H L W H L W H L W Design Water Temp. & f 2 ROOM DIMENSIONS, FT. U BTUH per Foct of 3 LENGTH EXPOSED WALLS, FT.Q Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL Tiv BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION rr I B/ / ROOM LIN. FT.OF Table 9, Line 3 x HI V I ?C' TOTALS RADIATION 6 TYPE OF GLASS L' ` FROM LINE 12 SELECTED T Bottom of table used for Line 5} 7 CEILING CONSTRUCTION rjl C Table 9, L x W)C g FLOOR CONSTRUCTIONt Table 9, L x W or Lin. Ft.) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x HI G 10 -0 1 Wall(With Openings) 03 r;11;.i III H__ cm 2 Walls(With Openings) X LL) I 3 Walls(With Openings)or Ent. Hall F- •/•s ] 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE' 4 '.•- K 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE L 77 COL.A COL.B COL.H COL.1 COL.J COL.K COL.L TOTALSTUH TOTAL 1 'ROOM OF BUILDING RADIATION E AT SELECTED O H L W H L W H L W H L W H L W DESIGNTEMP.° DIFFERENCE 2 ROOM DIMENSIONS,FT. U I 3 LENGTH EXPOSED WALLS, FT.Q 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTU 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 x H) F=1TOTAL 20% 6 TYPE OF GLASS Bottom of table used for Line 5) tFOR CONCRETE FLOOR ON 7 CEILING CONSTRUCTION GROUND OR FILL AT Table 9,L x W) GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9,L x W or Lin.Ft.) 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 c 1 Wall(With Openings) 0 3 c W 2 Walls(With Openings) D X I J 3 Walls(With Openings)or Ent. Hall F 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE FORM 1503 This form is available from The Hydronics Institute,35 Russo Place,Berkeley Heights,N J. 07922