Loading...
HomeMy WebLinkAbout145 Benedict Drive (23)DEPARTMENT DECISION PERNUT 4APPLICATIONFORHVACPERMIT Application is hereby: TOWN of SOUTH WINDSOR BUELDING DEPARTMENT Blda ermit# APPRO 1540 SULLIVAN AVENUE IX low, 644-2511 ext. 230 Date 3uilding Inspector Application must be printed or typed Location ofjob I L45 BENS i> i c T- 3>,z.FStreet No. Street Lot No. FEE SCHEDULE Floor Apt. No. 0 - $1,000 - $12.00 Over $1,000 1 12.00 per$1,000 OWNER Goranyfractionthereof ADDRESS I 9 S GeNg:c>icr OWNERS PHONE# APPLICANT/Ny M CtN SQL r(G. N 840 ADDRESS_HL4 Ld W F X Z 4( l l y r 0 V.-4 C ,r7 0 6 C),z ESTIMATED COST $ o0o. IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ ORC TYPE OF JOB: Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from rcvcrsc side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL _Z A/C COMMERCIAL VENTILATION INDUSTRIAL 11 EATING STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE F INSIDE F DIFFERENCE F TOTAL HEAT LOSS(BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) TYPE OF FUEL OIL-GPM GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE F INSIDE F D NCE I.3_F TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) Itt-HF_I L S \/ KA cotx1peNsea IT TONNAGE 3 '17, COOLING CAPACITY(BTUH) oc- VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK Tt"I S-Fv4 i,,'"`Q lj T e.N-ryz4 I 2 YV CM THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE oir PERFORMANCE OF SUCH WORK. t-7 3oovg4c STATE LICENSE-NO. NAME&TYPE SIGNATURE&APPLICANT PHONE NO. DATE Z IGHT-J LOAD AND EQUIPMENT SUMMARY rile name: SOUCY.BLD Fnr: 7HE GEHRIS RESIDENCE 145 BENEDICT DR SOU7H WINDSUR CT 06074 429-928 B»: HANY MECHANlCAL SERVICES 44 LOWER BUTCHER Rl` ELLIN87ON CT `)6O29 87Z-6 41 SlNGLE ZONEHartford .Brainard rield 7 Zone : Entire House WINTER DESIGN CUNDITIONS SUMMER DESIGN CONDITlDN Uutside db: 7 Deo F Outside db: 88 Deo F Inside dh: 70 Deo F Inszde dn: 75 D o F Deszon ln: 63 Deo F Deszon 7D: 3 Den F Dai ] kaooe M Graznp Water 35 o, HEATING SUM}1ARY SENSIBLE COOLING EUUIP LOAD SIZIHG Bldo . Hea+ Loss O Btuh Structure 324]0 8toh Ventilati tilatinn Btuh Veot Air Los O 8tuh Desioo Temo. Swino Deszon Heat Loau O Btuh Use IV fo . Data v Rate/Swinn Mult . 1 .0(' lNFILTPATIOH 7otal Sens Eouio Load 32430 Btuh Me+hod Simolified LATENT CDOLING EQUIP LOAD SIZIN Cons+rvc on Qua] itv Averaoe Fireo] aces 1 Internai Gains 322 Bt h Ventilatzon O B+"» HEATING [OOLING Infi J.tratzon r8 Btuh Area (so .f. ) o 18r0 Tot Latent Eouin Lnad 5598 Dtuh Vnlume wir Chanoes/Hour 1 .4 O.4 Tota] Eooio Load 38028 BLuh Eoo:Ivalent CFM HEATING EQUlPMENT SUMMwRY COOLING EQUIPMENT SUNMARY Makc H[IMaue L Model Hodel CA5542*K T`o 7~oe ac Efficieoc / HSPF 0.0 COP/EER/SEER 10.6 Heatioo Inoot O BtuI ihle Coolino 294 0 Btu,. Heati tout O Btuh iatent Coo1ino l2600 Btuh Heatino Temo R Deo F Total Coolzno 42O Btuh Ac ua1 Heatino Fan 1734 I::.IV)wctual Coolino Fan i734 CFM Hto Air F] ow Factor 0.000 FM/Bt h Clo Air Flow Fa` 'or O.O53 CFM/Btuh Snace Thermostat Load Sens Heat Ratio 85 MANUALS/H 508 Print t tifi d h A[A t t i1 i t f M i F P [GHT—J SHORT FURM S1-15-08 zle name: SOUCY.BLP 7oh #: Hto Cln For: [HE GEHKIS RESIDENCE Ov0szde db 145 BENEDICT DR 1ns` ue db SUUlH WlNDSOP r 060,/4 eszon TD 6J A.I".. 429-9282 S)ailv Ranoe M 1nszde Humid . - 50 B,: HmNY M[CHANICwi SERVI[ES Grains Water —3y. 44 LOWEP lot TCHER RD Method Simo1ified E LA.INGT[HN CT 06 ons L. o l t,Averaoe 872-6541 12.1reu1aces 1 HEATING EQUIPMENT COOL I). G EQUIPMEN7 Make Make Mode)ModeK 7 me Effzc poc / HSPF 0.0 COP/FER SEEK 0. Heatjoo lnout 0 Btuh Sensible Coolino O 8tuh Heatino Uutout 0 Btuh Latpnt Coo1ino Btuh tic;atzno Ypmo Rise 0 Deo F Total Cool ino Btuh Actual Fitton tino Fan 1734 CFM Artua1 [onlxno Fan 17154 CFM Hto Air F iow Fac CFM/Btuh Clo Air Flow Factor O53 CFM/Btuh Soace Thermostat Load Sensible Heat Katzn 85 ROOM NAME AREA BTUH CFM town or no on No IN Swas on no-1 on no IN no No No no an an no an=0 an no=:on LlVING RM DI NI RM 144 2607 0 | 139 KITCHEN 0 FAMILY RM 253 | 0 MmSTER BED RM 224 O 24 8 o | 1 0 MASTER BATH 96 9 IN, MUD RM 0 2409 BED RM # 144 BED RM #3 14A 1890 ! 0 ! lOz BED RM # 144 8 1On MAIN loll 7H O 18 2ND FL FOOL WAY, 104 | O | 802 ' 0 | 43 En ti re Hot tse d 1870 O ' 32430 V'y`ti1RKim) Air Eouio. 01 1 .00 RSM 243O | LaLent Coolino 98 TA:==========================noon================ 70TAL S MAN/)AL J: 7+h Ed . RI6HT-Jx V . l