HomeMy WebLinkAbout112 Bridlewood Road (6)ikLocationEABuildingPermit# v
SWIMMING POOL REQUIREMENTS:
This list is not all inclusive; please refer to pool packet.
A 48"barrier will be provided to protect the pool access. Including a temporary fence
for inground pools prior to filling.
Access gates will be self closing and self latching(if less than 54"high they shall be on
the pool side and be protected within 18"of release mechanism).
Doors providing direct access to the pool shall either have an alarm, a self closing self
latching device 54" above the floor, or a safety cover over the pool.
No receptacles within 10' of pool. (locking type receptacle for pool equipment must be
at least 5' from pool and GFCI protected).
All metal parts of pool structure, fixed metal parts within 5' of pool,pump motors etc.,
shall be bonded with a minimum#8 solid copper wire.
Convenience GFCI receptacle shall be provided between 10' and 20' from pool.
Trench depth for 20 amp. circuit to pool equipment shall be 12"minimum.
A surface pool alarm shall be installed pursuant to Public Act 99-140.
REQUIRED SWIMMING POOL INSPECTIONS:
The following is a list of inspections that need to be performed prior to the continuation of work.
Requests for inspections can be made by calling the Building Department at 644-2511 ext. 230.
1. TRENCH AND BONDING-Electrical trench depth verification and bonding of pool and
metal appurtenances including metal reinforcing for gunite pools.
2. FINAL ELECTRICAL-Location of equipment and GFCI protection. Convenience outlet
provided.
3. FINAL-Swimming pool access protection must be provided before pool can be used.
Each swimming pool installation requires a Building and an Electrical permit. Additional
permits and inspections are required for pool decks.
I have read and understand the requirements listed above.
Signed Date ,` 1